192061-01 [NI]
Cable Assembly, 68 Conductor(s);型号: | 192061-01 |
厂家: | National Instruments |
描述: | Cable Assembly, 68 Conductor(s) 连接器 连接器支架 |
文件: | 总5页 (文件大小:150K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SCXI Cable Assemblies
Overview
NI SCXI cable assemblies connect a DAQ device to the SCXI system.
They consist of high-quality, low-noise cables, which guarantee reliable
communication and signal integrity at up to 10 m. Therefore, you can
locate your SCXI system closer to your sensors and transducers.
For SCXI systems operating in multiplexed mode, you need only
one SCXI cable assembly per SCXI chassis. You must choose the
appropriate cable assembly for your DAQ device (see Table 1).
Multichassis multiplexed systems require an additional SCXI-1346
multichassis adapter and SH68-68-EP shielded cable for each
additional chassis. If your SCXI system includes modules operating
in parallel mode, you need an additional SCXI cable assembly for
each of these modules. Some PXI modules can control the SCXI
Computer with
E Series board
SCXI-1349
Cable Assembly
Figure 2. SCXI System with Shielded Cable Assembly
portion of the PXI-1010 and PXI-1011 chassis through an internal SCXI-1349 Shielded Cable Assembly (See Figures 1, 2)
connection, and do not require additional SCXI cable assemblies. For connecting 68-pin E Series devices (except DAQCards) to an
(see Table 1) For multichassis systems using the PXI-1010 or SCXI chassis. The SCXI-1349 consists of an SH68-68-EP shielded
PXI-1011, you can connect an additional SCXI chassis to the front cable and cable adapter with a 50-pin male breakout connector.
connector of the DAQ module. But if the SCXI chassis contains 1 m .....................................................................................776574-491
switch modules controlled by a PXI-4070, PXI-4060, or PXI-4021 2 m .....................................................................................776574-492
module, additional cabling is required. See page 507 for complete
switch cabling information.
SCXI-1349 Shielded Cable Components for DAQCards
Each SCXI cable assembly includes a cable and one or more SCXI For connecting a DAQCard (with latching connector) to an SCXI
cable adapters. The shielded cables use twisted pair wiring and chassis, purchase the SCXI-1349 Adapter and an SHC68-68-EP cable.
separately shielded analog and digital signals for maximum noise For a legacy DAQCard, (with nonlatching connector), purchase the
rejection. The cable adapter screws into a rear slot of the SCXI chassis SCXI-1349 adapter and a PSHR68-68 cable.
to hold the cable securely in place. Each cable adapter also has a 50-pin SCXI-1349 adapter................................................................182671-01
male breakout connector, for attaching additional DAQ accessories SHC68-68-EP cable
such as the SCXI-1180 feedthrough panel or a CB-50 terminal block.
0.5 m ...............................................................................186838-0R5
1 m.....................................................................................186838-01
PSHR68-68 cable
1 m.....................................................................................777293-01
Figure 1. SCXI-1349 Shielded Cable Assembly
PXI/SCXI Combination Chassis Cabling
Measurement Device
SCXI Chassis Cabling
Type
PXI-1010
PXI-1011
60xxE (E Series) with 68-Pin Connectors
DAQCard-AI-16E-4, DAQCard-AI-16XE-50
DAQCard-6062E, DAQCard-6024E
60xxE (E Series) with 100-Pin Connectors
PCI-DI0-32HS, AT-DIO-32HS, PXI-6533
DAQCard 6533
DAQCard-DIO-24
PCI-DIO-96, PXI-6508
PC-DIO-96/PnP
PXI-4070, NI 4021
SCXI-1349
SCXI-1349 with PSHR68-68M
SCXI-1349 Adapter only with SHC6868-EP
SCXI-1353
Shielded
Shielded
Shielded
Shielded
Shielded
Shielded
Ribbon
Ribbon
Ribbon
Shielded
Shielded
Internal1 or External
Internal1
N/A
N/A
N/A
Internal1 or External2
Internal1 or External2
N/A
N/A
Internal1
SCXI-1355
Internal1
SCXI-1355 with PSHR68-68M
SCXI-1351 with PSH27-50F-D1
SCXI-1351 with R1005050
NB5 with SCXI-1351
SCXI-13573 , SCXI-13583 , SCXI-13624
SCXI-1355
N/A
N/A
N/A
N/A
External2
N/A
N/A
Internal5 or erxternal6
N/A
Internal5 or External6
N/A
PCI-6534 PXI-6534
1Requires no external cabling. 2Requires same cabling as SCXI Chassis. 3For use with SCXI-1127/1128/1129. 4For use with SCXI-1160/1161/1163R/1190/1191.
5Digital control only, measurements of switched signals with the PXI-4070 or NI 4060 require external cabling. 6See page 507 for switch cabling information
Table 1. SCXI Chassis Cabling
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com 337
SCXI Cable Assemblies
SCXI-1353 Shielded Cable Assembly (See Figure 3)
For connecting 100-pin E Series devices to an SCXI chassis. The SCXI-1353 consists
of an SH1006868 cable and two SCXI cable adapters with 50-pin male breakout
connectors. The first adapter is identical to the SCXI-1349, while the second adapter
routes the extended analog or digital signals to SCXI digital modules or
breadboarding modules.
1 m ..................................................................................................................776575-531
2 m ..................................................................................................................776575-532
Figure 3. SCXI-1353 Cable Assembly
SCXI-1355 Shielded Cable Assembly (See Figure 4)
For connecting the PCI-DIO-32HS, AT-DIO-32HS, PXI-6533, DAQCard-6533,
PCI-6534 or PXI-6534 to an SCXI chassis. The SCXI-1355 consists of an SH6868-D1
cable and an SCXI cable adapter. The DAQCard-6533 requires an additional
PSHR68-68M cable.
1 m ..................................................................................................................776575-551
2 m ..................................................................................................................776575-552
SCXI-1356 Shielded Cable Assembly (See Figure 5)
Figure 4. SCXI Cable Assembly Connected to Rear of SCXI Chassis
For connecting VXI-MIO Series modules to an SCXI chassis. The SCXI-1356
consists of an SH96-6868 cable and two SCXI cable adapters with 50-pin male
breakout connectors.
1 m ..................................................................................................................776575-561
2 m ..................................................................................................................776575-562
SCXI-1357, SCXI-1358 High-Voltage Backplane Assemblies
High-voltage backplane assemblies for the SCXI-1127, SCXI-1128 and SCXI-1129
multiplexer/matrix modules. The SCXI-1357 consists of a 4-slot high-voltage
backplane, two cables for routing analog and digital signals to an external scanning
DMM, and analog bus plugs for connecting the backplane components. The SCXI-1358
is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. To add more
chassis to your high-voltage backplane configuration, purchase one add-on kit for
each chassis added. You can intermix 4 and 12-slot chassis.
Figure 5. SCXI-1356 Cable Assembly
SCXI-1357 (4-Slot) (See Figure 6)
1 m cables ......................................................................................................776575-571
2 m cables ......................................................................................................776575-572
Add-on chassis kit (4-slot) ..........................................................................776575-57M
Figure 6. SCXI-1357 High-Voltage Backplane
SCXI-1358 (12-Slot)
1 m cables ......................................................................................................776575-581
2 m cables ......................................................................................................776575-582
Add-on chassis kit (4-slot) ..........................................................................776575-58M
338 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com
SCXI Cable Assemblies
SCXI-1343 Rear Screw Terminal Adapter
A general-purpose SCXI adapter with screw terminals for custom cable solutions to
external instrumentation hardware.
SCXI-1343 ........................................................................................................776574-43
SCXI-1346 Multichassis Adapter (See Figure 7)
For connecting multiple SCXI chassis to a single DAQ device. The SCXI-1346
occupies two rear slots, and routes the analog and digital DAQ signals to the next
chassis. You must purchase an SCXI-1346 for each additional chassis you want to add
to your system. You must purchase an additional SH68-68-EP with each SCXI-1346.
SCXI-1346 Adapter ..........................................................................................776574-46
SH68-68-EP Cable
Figure 7. SCXI-1346 Multichassis Adapter
Figure 8. SCXI-1351 One-Slot Cable Extender
Figure 9. SCXI-1362 Cable Assembly
1 m ....................................................................................................................184749-01
2 m ....................................................................................................................184749-02
5 m ....................................................................................................................184749-05
10 m ..................................................................................................................184749-10
SCXI-1351 One-Slot Cable Extender (See Figure 8)
For connecting DAQCard-DIO-24, DIO-96 Series, PXI-6508, or SCXI-1181 devices
to your SCXI system. You insert the SCXI-1351 into a rear slot next to an SCXI-1181
and attach the provided ribbon cable to connect your SCXI-1181 to your SCXI
system. See Table 1 for additional required cabling when using the SCXI-1351 with
digital devices such as the PXI-6508.
SCXI-1351 ........................................................................................................776575-51
SCXI-1362 Cable Assembly (See Figure 9)
For connecting the NI 4021 Switch Controller, the PXI-4070 FlexDMM, or an
NI 4060 DMM to an SCXI system containing the SCXI-1160/1161/1163R/1166/1190/
1191/1193. If the chassis contains the SCXI-1127/1128/1129, use the SCXI-1357 or
SCXI-1358.
1 m ..................................................................................................................776575-621
2 m ..................................................................................................................776575-622
SCXI Chassis
SCXI-1349 or SCXI-1353 adapter
SH6868-EP cables
Computer with
E Series board
SCXI-1346
multichassis
adapter
SH6868-EP or
SH1006868 cable
Figure 10. Multichassis SCXI System with Shielded Cabling Assemblies
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com 339
SCXI Accessories
SCXI-1180 Feedthrough Panel (See Figure 1)
Extends the I/O signals of the DAQ device to the front of the SCXI chassis. It occupies
one slot of your SCXI system and easily connects to your SCXI cable accessory.
You can also use the SCXI-1180 to route the I/O signals of separate DAQ devices to
the front of your SCXI system for convenience.
SCXI-1180 ........................................................................................................776572-80
SCXI-1181 Breadboard (See Figure 2)
Figure 1. SCXI-1180 Feedthrough Panel
A breadboard module with a 13.3 by 17.8 cm. (5.25 by 7 in.) breadboard area for
integrating custom circuitry into your SCXI system. This module can connect to the
DAQ device controlling the SCXI system by installing an SCXI-1351 one-slot cable
extender next to the controlling SCXI cable assembly.
SCXI-1181 ........................................................................................................776572-81
SCXI-1181K Module Developer Accessory
A kit of unassembled module parts, including front and rear connectors and
aluminum module housing. It is useful for custom module development with custom
printed circuit boards. It does not include a breadboard or printed circuit board, but
it does include dimensions needed for designing a custom board. The front connector
is a standard 96-pin male DIN C connector, compatible with the SCXI-1300/1301/
1381K or TBX-1303 terminal block kits.
Figure 2. SCXI-1181 Breadboard
Internal 16-pin
Input Connector
SCXI-1181K ..................................................................................................776572-81K
SCXI-1532 Cable
SCXI-1381K Terminal Block Developer Accessory
A kit of unassembled terminal block components for developing custom SCXI
terminal blocks. This kit includes the terminal block housing, strain-relief assembly,
and 96-pin DIN connector for mating with SCXI modules. This kit does not include
a printed circuit board or screw terminals for signal connection.
SCXI-1140 or
SCXI-1141
Module
SCXI-1140 or SCXI-1141
Isolation Amplifier Module
Analog Input Signals
Figure 3. SCXI-1352 Cable for Cascading Modules
SCXI-1381K ..................................................................................................777687-81K
SCXIbus Extender
Tech Tip
With the SCXIbus extender, you can operate the module outside of the chassis, which
is useful for developing and debugging custom modules.
SCXIbus Extender ............................................................................................181585-01
Most SCXI chassis require AC power. However,
you can use off-the-shelf true sine wave DC to AC
power inverters to power the chassis with a DC
power supply.
SCXI-1352 Module-Cascading Cable Kit (See Figure 3)
A kit containing two ribbon cables (R1650 and R165050) for connecting the
conditioned output of an SCXI module (operating in parallel mode) directly to the
input of an adjacent module.
SCXI-1352 ........................................................................................................776575-52
SCXI-1360 Chassis Filler Panels
Front filler panels cover unused chassis slots and rear filler panels cover the rear slots
not occupied by cable assemblies, multichassis adapters, one-slot cable extenders, or
SCXI-1357/SCXI-1358 high-voltage backplane units.
SCXI-1360 front filler panel............................................................................776576-60
SCXI-1361 rear filler panel..............................................................................776576-61
340 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com
SCXI Accessories
Rack-Mount Kits (See Figure 4)
Holds SCXI chassis in standard 19 in. rack-enclosures. Each kit offers multiposition
capability for both recessed and flush mounting.
SCXI-1370 rack-mount kit (SCXI-1001, PXI-1010)......................................776577-70
SCXI-1371 rack-mount kit (SCXI-1000/1000DC) ........................................776577-71
SCXI-1372 dual rack-mount kit (SCXI-1000/1000DC)................................776577-72
PXI-1011 rack-mount kit ................................................................................778074-01
SCXI-1373 Panel-Mount Kit (See Figure 5)
Figure 4. SCXI-1370 Rack-Mount Kit
Mounts any 4-slot or 12-slot chassis to a panel or wall. You can mount the chassis
facing up or down, leaving clearance for front and rear cabling. You can also rotate the
chassis for access to both the front and rear of the chassis.
SCXI-1373 ........................................................................................................776577-73
SCXI-1374 Chassis Handle Kit (See Figure 6)
A chassis handle that easily attaches to either side of the SCXI chassis or SCXI-1382
battery pack. It is ideal for applications requiring increased mobility.
SCXI-1374 ........................................................................................................776577-74
Figure 5. SCXI-1373 Panel Mount in rotated position
SCXI Process Current Resistor Kit
A pack of four precision resistors for measurements of 0 to 20 mA and 4 to 20 mA
current inputs. Each resistor is a 249 , 0.1%, 5 ppm/°C, 0.25 W high-precision
resistor. For use with the terminal blocks for the SCXI-1120/D, 1121, 1140, 1141,
1142, 1143, 1100, 1102, and 1122.
SCXI Process Current Resistor Kit..................................................................776582-01
SCXI-1382 Battery Pack (See Figure 7)
A 12 VDC, 25 Ah (ampere hour) battery pack that attaches directly to the
SCXI-1000DC. It can power a fully loaded chassis for a minimum of five hours.
The optional dual-stage power supply battery charger can charge a completely
discharged battery in 8 to 11 hours, and is sold separately (SCXI-1383).
SCXI-1382 ......................................................................................................776577-820
Figure 6. SCXI-1374 Chassis Handle
SCXI-1383 Power Supply
A 13.8 VDC, 4 A power supply/float charger for the SCXI-1000DC, which accepts
100 to 240 VAC power input. The SCXI-1382 can be combined with the SCXI-1383
to operate in standby mode and provide uninterruptible power to the SCXI-1000DC
chassis. The SCXI-1383 will recharge a completely discharged SCXI-1382 battery
pack in 12 to 14 hours.
Figure 7. SCXI-1000DC Chassis, SCXI-1382 Battery Pack and
SCXI-1374 Handle Accessory
U.S. 120 VAC/Japanese 100 VAC ..................................................................776577-831
Swiss 220 VAC ................................................................................................776577-832
Australian 240 VAC........................................................................................776577-833
Universal Euro 240 VAC ................................................................................776577-834
North American 240 VAC..............................................................................776577-835
United Kingdom 240 VAC ............................................................................776577-836
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com 341
相关型号:
19207-12294649-3
Snap Acting/Limit Switch, SPDT, Momentary, 28VDC, 1.27mm, Wire Terminal, Steel Roller Plunger Actuator, Panel Mount-threaded
HONEYWELL
©2020 ICPDF网 联系我们和版权申明