591-593 4 Channel Mono 10/28/08 1:35 PM Page 591  
4-Channel Monochrome Image Acquisition  
NI 1409  
• Up to 4 standard or nonstandard  
video sources  
Operating Systems  
• Windows 2000/NT/XP/Me/9x  
• 8 or 10-bit digitization  
• Compatible with double-speed  
60 frames/s progressive  
Recommended Software  
• LabVIEW  
• Measurement Studio  
• Vision Development Module  
- IMAQ Vision  
scan cameras  
• Interlaced/noninterlaced acquisition  
• Analog area and line-scan capabilities  
• Unlimited acquisition window size  
with 16 MB of onboard memory  
Triggering  
- NI Vision Builder  
Other Compatible Software  
• C/C++  
- 4 external triggers/digital I/O lines  
- 4 digital outputs for camera control  
RTSI bus for synchronization with  
DAQ and motion  
Driver Software (included )  
• NI-IMAQ  
Models  
• NI PCI-1409  
• NI PXI-1409  
Overview and Applications  
10-Bit Image Acquisition  
INFO CODES  
For more information  
or to order products  
online, visit ni.com/info  
and enter:  
For machine vision and scientific imaging developers who need  
to acquire high-resolution, measurement-quality images from  
standard and nonstandard cameras and sensors, the NI 1409  
image acquisition hardware offers quick and easy configuration.  
NI 1409 devices have high-resolution, 10-bit digitization for  
cameras and sensors that offer 60 dB dynamic range. In addition,  
you can easily configure the NI 1409 Series to work with standard  
monochrome cameras (RS-170 or CCIR), slow or variable rate  
pixel clock cameras, double-speed progressive scan cameras, and  
analog line-scan cameras.  
Many high-resolution analog mono-  
chrome cameras have dynamic range  
greater than 48 dB, which means that  
the camera has resolution capabilities  
greater than 8-bit or 256 gray scales.  
For these high-resolution cameras,  
you should use an image acquisition  
device that offers comparable or  
greater resolution. The NI 1409 Series  
pci1409  
pxi1409  
BUY ONLINE!  
works with the highest quality monochrome cameras and  
delivers up to 60 dB of dynamic range, which corresponds to  
10 bits or 1,024 gray scales. With NI 1409 devices, you have the  
option to acquire in 8-bit or 10-bit mode at very high rates, such  
as 60 frames/s with double-speed progressive scan cameras.  
Measurement-Quality  
Image Acquisition with Calibration  
NI 1409 devices are gain calibrated and delivered with a  
calibration certificate. Calibration ensures repeatable, consistent  
image acquisition for your machine vision and scientific Interchange Cameras with NI-IMAQ  
imaging applications.  
NI-IMAQ driver software for image acquisition can scale between  
many types of cameras and acquisition methods. With NI-IMAQ,  
you can begin by using a low-cost RS-170 camera and image  
acquisition device and then upgrade to a faster, higher-resolution  
camera and acquisition hardware with minimal software changes.  
Because NI-IMAQ driver software uses one set of function  
calls for a wide variety of cameras, there is no need to rewrite  
your software.  
Variable Scan and Nonstandard Video  
With NI 1409 devices, you can acquire images from nonstandard  
video, such as analog line-scan and variable-scan devices with  
pixel clocks that range from 2 to 40 MHz. The NI 1409 devices  
work with double-speed (60 frames/s) progressive scan or  
noninterlaced monochrome cameras from vendors such as  
Sony and JAI.  
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com 591  
591-593 4 Channel Mono 10/28/08 1:35 PM Page 592  
4-Channel Monochrome Image Acquisition  
Quick and Easy Camera Configuration  
DAQ Synchronization  
You can easily configure standard and nonstandard video capture  
with NI Measurement & Automation Explorer, delivered with  
NI-IMAQ. This utility is an interactive tool for setting the camera  
type (RS-170, CCIR, NTSC, and PAL), programmable ROI, aspect  
The RTSI bus or PXI trigger bus provide a flexible synchronization  
scheme between any National Instruments IMAQ, DAQ, or  
motion device and your PCI-1409 or PXI-1409, respectively.  
ratio, and antichrominance filter. Use this interactive utility to set Trigger Control and Mapping Circuitry  
up acquisition from noninterlaced progressive-scan cameras and  
to create your own camera configurations for nonstandard video.  
Use the external lock feature to set variable-scan acquisition for  
microscopes and other sources that generate their own pixel  
clock and horizontal and vertical synchronization signals.  
The trigger control and mapping circuitry routes, monitors, and  
drives the external and RTSI or PXI trigger bus lines. You can  
configure each of these lines to start or stop acquisition on a rising  
or falling edge, or use each line as digital I/O. You can also map  
the lines to onboard status values (CSYNC, Acquisition in  
Progress, and Acquisition Complete).  
Image Acquisition Performance Gains  
with Partial Image Scanning  
Antichrominance and Lowpass Filter  
For improved throughput and processing bandwidth, the  
acquisition and ROI control circuitry monitors the incoming video  
signal and routes the active pixels to the FIFO. In addition to being  
able to digitize an entire frame, an NI 1409 can perform pixel and  
line scaling (decimation) and ROI acquisition. With pixel and line  
scaling, multiples (2,4,8) of pixels and/or lines can be transferred  
to the PCI bus. Using ROI acquisition, you select an area in the  
acquisition window that will be transferred to the PCI bus.  
NI 1409 devices have an antichrominance filter, which can remove  
chrominance information from a color video signal. There are two  
software selectable antichrominance filters – one for NTSC color  
-coded signals (a 3.58 MHz notch filter), and another for PAL color  
-coded signals (a 4.43 MHz notch filter). Use the lowpass filter at  
9 MHz to remove unwanted noise.  
10-Bit A/D and Look-Up Table (LUT)  
An A/D converter performs the image digitization, the result of  
which passes to a 1,024 by 10 RAM LUT. You can configure the  
LUT to implement simple imaging operations, such as gamma  
manipulation, contrast enhancement, data inversion, or any  
nonlinear transfer function.  
Hardware  
PCI Interface  
The PCI bus is the electrical interface for both NI PCI-1409 and  
NI PXI-1409. The PCI interface, implemented with the National  
Instruments MITE ASIC, can transfer data at a maximum  
sustained rate of 100 Mbytes/s in master mode to maximize the Programmable Gain and Offset  
use of the available bandwidth. The interface logic ensures that  
the NI 1409 meets the loading, driving, and timing requirements  
of the PCI specification.  
The NI 1409 has programmable gain and offset circuitry for  
optimizing the input signal range.  
VCR Circuitry  
Scatter-Gather DMA Controllers  
Because many commercial and home VCRs have noisy  
synchronization signals or no synchronization at all, VCRs are  
difficult to use with most image acquisition hardware. However,  
with its built-in circuitry and logic for handling video signals from  
VCRs, the NI 1409 can acquire monochrome images from VCRs.  
An NI 1409 has three independent onboard DMA controllers. The  
DMA controllers can transfer data between the Host memory and  
the onboard FIFO via the PCI bus. Each of these controllers  
performs scatter-gather DMA, which means the DMA controller  
can reconfigure on the fly, and thus perform continuous image  
transfers to either contiguous or fragmented buffers.  
Digital I/O  
The NI 1409 Series includes four general-purpose digital  
input/output lines for general-purpose triggering and pulse  
generation capabilities. In addition, each NI 1409 includes four  
digital output lines for lighting, shutter, camera control, and  
pulse generation.  
Onboard Memory  
An NI 1409 has 16 MB of onboard memory used to temporarily  
store the image being transferred to the PCI bus. With 16 MB,  
you can buffer large images during image acquisition.  
592 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com  
591-593 4 Channel Mono 10/28/08 1:35 PM Page 593  
4-Channel Monochrome Image Acquisition  
BNC Connector  
The BNC connector supplies an immediate connection to the  
VIDEO0 input of the NI 1409. Use the 2 m BNC cable shipped  
with the NI 1409 to connect a camera to VIDEO0. You can  
configure the BNC connector only for RSE mode.  
Ordering Information  
NI PCI-1409 ..........................................................778200-01  
NI PXI-1409 ..........................................................778336-01  
Includes the NI 1409 hardware, NI-IMAQ software  
and a 2 m NI-BNC-1 cable.  
NI 1409 Cable Accessories  
The IMAQ-A6822 cable provides 22 BNC connectors to all video  
signals (VIDEO0, VIDEO1, VIDEO2, and VIDEO3), the external  
digital I/O lines and triggers, and external signals. The IMAQ  
A6804 provides four bus connectors to three video signals and  
one trigger line. The IMAQ SCB-68 provides access to all of the  
signals on the NI 1409 68-pin connector.  
Cables  
IMAQ-A6822 (1 m) ..............................................778135-01  
IMAQ-A6804 ........................................................187805-01  
IMAQ-BNC-1 (2 m) ..............................................183882-02  
IMAQ-SCB 68 ......................................................778410-01  
RTSI Bus Cables  
Warranty and Support Services  
As a complement to your image acquisition product, consider:  
Technical Support: FREE through Applications Engineers  
worldwide, Web resources, and Premier Support –  
ni.com/support  
2 boards................................................................776249-02  
3 boards................................................................776249-03  
4 boards................................................................776249-04  
5 boards................................................................776249-05  
Specifications  
CSYNCIN sense......................................... Selectable (TTL or RS-422)CSYNCIN  
level programmable (rising or falling)  
Pulse width................................................ 20 ns minimum detectable  
VIH (TTL).................................................... 2 V  
Typical for 25 °C unless otherwise stated  
Available Formats  
RS-170/NTSC ............................................. 30 frames/s interlaced  
CCIR-601/PAL ............................................ 25 frames/s interlaced  
Progressive scan........................................ 60 frames/s noninterlaced maximum  
Variable scan.............................................. 2 to 40 MHz pixel clock  
VIL (TTL)..................................................... 0.8 V  
Video Input  
Quantity ..................................................... 4 monochrome  
Video 0....................................................... Single-ended (BNC)  
Video (0:3).................................................. Single-ended or differential (D-Sub)  
Input impedance........................................ 75 Ω 1%  
Bandwidth.................................................. Typical 30 MHz (-3 dB)  
Input range (black and white) .................... 700 MV (calibrated) or  
50mV to 1.4V (variable gain)  
Pixel Clock  
Internally generated  
Frequency range.................................... 11.0 to 25.8 MHz  
Adjustable pixel aspect ratio  
RS-170/NTSC......................................... 5%  
CCIR/PAL ............................................... 5%  
Pixel jitter................................................... <2 ns  
Lock time................................................... <1 frame  
External PCLK frequency range................. 2 to 40 MHz  
Antichrominance filter................................ Programmable  
3.58 MHz notch filter (<-25 dB)  
4.43 MHz notch filter (<-25 dB)  
Power Requirements  
A/D Conversion  
+5 VDC ( 5%) ........................................... 1.25 A  
+12 VDC ( 5%) ......................................... <100 mA  
–12 VDC ( 5%).......................................... <100 mA  
Gray levels ................................................. 256 (8 bits) or 1,024 (10 bits)  
DNL............................................................ 1 LSB maximum  
RMS noise ................................................. < 0.5 LSB rms  
SNR............................................................ Typical 56 dB  
Sampling rate............................................. 2 to 40 MHz  
Physical  
Dimensions  
PCI ......................................................... 10.7 by 17.5 cm (4.2 by 6.9 in.)  
PXI.......................................................... 10 by 16 cm (3.9 by 6.3 in.)  
External Synchronization and Trigger Signals  
Trigger lines................................................  
4
Trigger sense ............................................. TTL  
Environment  
Trigger polarity ........................................... Programmable (rising or falling)  
PCLKIN sense............................................ Selectable (TTL or RS-422)  
PCLKIN polarity.......................................... Programmable (direct or invert)  
HSYNCIN sense......................................... Selectable (TTL or RS-422)  
HSYNCIN polarity....................................... Programmable (rising or falling)  
VSYNCIN sense......................................... Selectable (TTL or RS-422)  
VSYNCIN polarity....................................... Programmable (rising or falling)  
Operating temperature .............................. 0 to 55 ˚C  
Storage temperature.................................. -20 to 70 ˚C  
Relative humidity ....................................... 5 to 90%, noncondensing  
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com 593  

相关型号:

778442-01

24-Bit, 204.8 kS/s Dynamic Signal Acquisition and Generation
NI

778465-01

Low-Cost E Series Multifunction DAQ-12 or 16-Bit, 200 kS/s, 16 Analog Inputs
NI

778466-01

Ethernet Control of PXI
NI

778467-01

Ethernet Control of PXI
NI

778467-33

Ethernet Control of PXI
NI

778468-01

Ethernet Control of PXI
NI

778468-33

Ethernet Control of PXI
NI

778469-256

Ethernet Control of PXI
NI

778469-512

Real-Time Embedded Controllers for PXI
NI

778492-01

Ethernet Control of PXI
NI

7785-30

Audio/RCA Connector
WINCHESTER

7785-32

Audio/RCA Connector, Jack
WINCHESTER