100 and 50 MHz, Programmable-Voltage  
Digital Waveform Generator/Analyzers  
NI 655x  
• 100 MHz maximum clock rate  
Operating Systems  
• Windows 2000/NT/XP  
• LabVIEW Real-Time  
• -2.0 to 5.5 V programmable voltage  
levels in 10 mV steps  
• 20 channels with per-channel, per-cycle  
bidirectional control  
• 1, 8, or 64 Mb/channel onboard memory  
• Real-time hardware comparison of  
acquired data  
Recommended Software  
• LabVIEW  
• LabWindows/CVI  
• SignalExpress  
• Complex triggering and pattern  
sequencing  
• Interactive waveform and script  
editor software  
• Synchronization and Memory Core  
(SMC) for tight synchronization with  
other SMC-based devices  
Driver and Editing Software  
(included)  
• NI-HSDIO driver  
• Script Editor  
• Digital Waveform Editor  
(included with 8 and  
64 Mb/channel models)  
Calibration  
• NIST traceable  
• 2-year external calibration cycle  
Maximum Clock  
Rate (MHz)  
Memory  
(Mb/channel) (Linking/Looping)  
Scripting  
Programmable Per-Cycle  
Hardware  
Comparison  
Product Platform  
Channels  
Voltage Levels  
Data Delay  
Tristate  
NI 6552  
NI 6551  
PCI, PXI  
PCI, PXI  
20  
20  
100  
50  
Programmable, 10 mV steps  
Programmable, 10 mV steps  
1, 8, or 64  
1, 8, or 64  
Table 1. NI 655x Selection Guide  
Overview  
Design High-Performance Tests  
For building high-performance stimulus-response systems, the NI 655x  
The National Instruments 6552 and  
6551 are 100 and 50 MHz digital  
waveform generator/analyzers,  
respectively, for characterizing,  
validating, and testing digital  
Applications  
Semiconductor  
devices include:  
• A sophisticated timing engine to adjust for the timing parameters  
of the device under test  
Mixed-signal design validation and test  
Interfacing to digital electronics  
Aerospace/Defense  
Subsystem emulation  
• Programmable voltage levels for testing multiple devices or  
characterizing a single device under changing conditions  
• Per-cycle tristate for bidirectional communication  
• A versatile memory architecture for maximum flexibility of waveform  
and scripting memory  
Bit error rate tester (BERT)  
electronics. These modules feature  
20 channels with per-channel,  
Communications  
Multimedia chipset emulation  
per-cycle direction control and deep  
onboard memory with triggering and  
pattern sequencing. You can program  
the voltage levels on NI 655x devices  
Consumer Electronics  
CMOS and CCD imaging sensors  
Digital display tests  
The hardware architecture is designed to preserve high signal quality,  
and an eye diagram of the PXI-6552 generation is shown in Figure 1.  
You can use the internal clock or an external clock, such as from the  
NI PXI-5404, through the front panel. You can also shift the data  
generated, data acquired, and exported sample clock relative to the  
onboard clock for clock frequencies above 25 MHz, which is critical to  
adjust for propagation delays and setup-and-hold times in the device  
under test.  
with 10 mV resolution. You can use them with the NI Digital Waveform  
Editor, an interactive software tool for creating, editing, and importing  
digital waveforms. With the SMC, you can create mixed-signal test  
systems with digitizers, arbitrary waveform generators, and other digital  
waveform generator/analyzers, or you can synchronize multiple digital  
waveform devices to build high-channel-count test systems.  
Programmable voltage levels are needed when testing different  
devices or when characterizing how a given device performs under  
changing conditions. With NI 655x devices, the high and low levels for  
100 and 50 MHz, Programmable-Voltage  
Digital Waveform Generator/Analyzers  
acquisition and generation can be set independently. You can program  
the voltage levels between -2.0 and 5.5 V with 10 mV resolution for TTL,  
LVTTL, LVCMOS, ECL, PECL, and other signal level compatibility.  
The SMC memory architecture is designed for maximum flexibility  
between waveform memory and scripting memory, the instructions for  
pattern linking and looping. Using a single memory bank, you can  
allocate as much memory as needed for script and waveform data, giving  
you maximum flexibility from test to test.  
Driver Software  
NI 655x devices include the NI-HSDIO driver with an intuitive, powerful  
API based on IVI guidelines. The Windows-compatible NI-HSDIO driver  
provides an API for LabVIEW, SignalExpress, LabWindows/CVI, and other  
text-based development environments.  
Figure 1. Eye Diagram of NI PXI-6552 Generation  
Create Digital Waveforms Interactively  
with the Digital Waveform Editor  
Figure 2. Digital Waveform Editor with ASCII and VCD Import Wizards  
With the NI Digital Waveform Editor, an interactive software tool for  
creating and editing digital waveforms, you can import existing test  
patterns from popular spreadsheet and VHDL simulation packages in  
ASCII or value change dump (VCD) formats. Once imported, you can view  
the waveforms graphically and edit them interactively for new devices or  
new test conditions. You can also build new waveforms with built-in fill  
patterns such as pseudorandom bit sequences (PRBS) and count  
up/down patterns. When ready to test your device, the waveforms import  
seamlessly into NI LabVIEW, SignalExpress, and C. The Digital Waveform  
Editor is included with the 8 and 64 Mb/channel memory models, and is  
a separate add-on for use with the 1 Mb/channel model.  
Ordering Information  
NI PCI-6551 ................................................................778950-0M1  
NI PCI-6552 ................................................................778951-0M1  
NI PXI-6551 ................................................................778538-0M1  
NI PXI-6552 ................................................................778539-0M1  
1Where M is: 1 (1 Mb/channel), 2 (8 Mb/channel), or 3 (64 Mb/channel)  
Includes NI 655x device and NI-HSDIO driver. The 8 and 64 Mb/channel models also  
include the Digital Waveform Editor.  
Software  
NI Digital Waveform Editor ..........................................778724-03  
Build Tightly Synchronized Mixed-Signal Test Systems  
NI 655x devices use the same SMC architecture as the NI 5122 high-  
resolution digitizers and NI 5441 arbitrary waveform generators, so you  
can combine these devices to build tightly synchronized mixed-signal  
prototyping and test systems. For tight timing requirements, these PXI  
modules phase-lock to the 10 MHz reference clock on the PXI backplane.  
If you have an external precision reference, you can import it through the  
front panel SMB connector.  
Cable  
SHC68-C68-D2 ..............................................................188142-01  
SHC68-HIX38 ..............................................................192681-1R5  
Accessories  
CB-2162 ........................................................................778592-01  
SMB-2163......................................................................778749-01  
BUY NOW!  
For complete product specifications, pricing, and accessory  
information, call (800) 813 3693 (U.S. only) or go to ni.com.  
BUY ONLINE at ni.com or CALL (866) 265 9891 (U.S.)  
2
100 and 50 MHz, Programmable-Voltage  
Digital Waveform Generator/Analyzers  
Specifications  
These specifications are valid for the following temperature ranges: PXI: 0 to 55 °C, PCI: 0 to 45 °C.  
Channel Characteristics  
Number of data channels ...................................................... 20  
Direction control of data channels........................................ Per-channel, per-cycle  
Generation Signal Characteristics (data, DDC ClkOut, and PFI <0..3> channels)  
All voltage ranges specified into 1 M  
Generation voltage range...................................................... -2.0 to 5.5 V  
Generation signal type .......................................................... Single-ended  
Number of programmable voltage levels.............................. 1 voltage low level and 1 voltage high level applies to all data,  
Clk Out (sample clock only), and PFI channels  
Generation voltage range restrictions................................... -0.5 to 5.5 V (up to 50 MHz clock rate)  
-2 to 3.7 V (up to 50 MHz clock rate)  
-0.5 to 3.7 V (50 to 100 MHz clock rate; NI 6552 only)  
Generation voltage swing ..................................................... 400 mV to 6 V (up to 50 MHz clock rate)  
400 mV to 4.2 V (50 to 100 MHz clock rate; NI 6552 only)  
Generation voltage-level resolution...................................... 10 mV  
DC generation voltage-level accuracy................................... 20 mV (excluding system crosstalk)  
Output impedance.................................................................. 50  
Maximum DC drive strength.................................................. 50 mA maximum per channel  
600 mA maximum for all data, clock, and PFI channels  
Channel power-up state ........................................................ Drivers disabled, 10 k input impedance  
nominal at 25 °C  
Acquisition Signal Characteristics (data, strobe, and PFI <0..3> channels)  
Acquisition voltage range...................................................... -2.0 V to 5.5 V  
Number of programmable acquisition thresholds ................ 1 voltage low threshold and a strobe voltage high threshold applies to all data  
and PFI channels  
Minimum detectable voltage swing...................................... 50 mV  
Acquisition voltage threshold resolution .............................. 10 mV  
DC acquisition voltage threshold accuracy........................... 30 mV (excluding system crosstalk)  
Input impedance .................................................................... 50  
or 10 k(default), software-selectable per channel;  
applies when powered on and within valid voltage range  
Timing Characteristics  
Sample Clock  
Sample clock sources ............................................................ 1. Onboard clock (internal VCXO with divider)  
2. CLK IN (SMB jack connector)  
3. PXI_STAR (PXI backplane; PXI only)  
4. STROBE (DDC Connector) – Acquisition only  
Onboard clock frequency range ............................................ NI 6551: 48 Hz to 50 MHz. (settable to 200 MHz/N; 4  
NI 6552: 48 Hz to 100 MHz (settable to 200 MHz/N; 2  
N
4,194,304)  
N 4,194,304)  
Exported sample clock delay range....................................... 0 to 1 sample clock periods for clock frequencies  
25 MHz  
Exported sample clock delay resolution................................ 1/256 of sample clock period for clock frequencies  
25 MHz  
Exported Sample Clock Jitter (typical using onboard clock)  
Period jitter  
Cycle-to-cycle jitter  
20 ps (rms)  
35 ps (rms)  
BUY ONLINE at ni.com or CALL (866) 265 9891 (U.S.)  
3
100 and 50 MHz, Programmable-Voltage  
Digital Waveform Generator/Analyzers  
Generation Signal Characteristics (data, DDC Clk Out, and PFI <0..3> channels)  
Data channel-to-channel skew.............................................. 300 ps (typical across all data channels)  
900 ps (maximum across all data channels)  
Maximum data channel toggle rate...................................... NI 6551: 25 MHz; NI 6552: 50 MHz  
Data formats.......................................................................... NRZ  
Data position modes.............................................................. Rising edge, falling edge, delayed relative to sample clock  
Generation data delay range................................................. 0 to 1 sample clock period for clock frequencies  
25 MHz  
Generation data delay resolution.......................................... 1/256 of sample clock period for clock frequencies  
25 MHz  
Acquisition Signal Characteristics (data, strobe, and PFI <0..3> channels)  
Channel-to-channel skew...................................................... 400 ps (typical across all data channels)  
900 ps (maximum across all data channels)  
Minimum detectable pulse width ......................................... 4 ns (required at both acquisition voltage thresholds)  
Acquisition timing delay range.............................................. 0 to 1 sample clock periods for clock frequencies 25 MHz  
25 MHz  
Acquisition timing delay resolution....................................... 1/256 of sample clock period for clock frequencies  
Waveform Characteristics  
Memory and Scripting  
Onboard memory size  
(assumes no scripting  
instructions)  
1 Mb/channel  
(for generation sessions)  
8 Mb/channel  
(for generation sessions)  
64 Mb/channel  
(for generation sessions)  
1 Mb/channel  
8 Mb/channel  
64 Mb/channel  
(for acquisition sessions)  
(for acquisition sessions)  
(for acquisition sessions)  
Generation Modes  
Waveform: Generate a single waveform once, N times, or continuously.  
Scripted: Generate a simple or complex sequence of waveforms. Use scripts to describe the waveforms to be generated,  
the order in which the waveforms are generated, how many times the waveforms are generated, and how the device  
responds to script triggers.  
Triggers (inputs to the NI 655x)  
Trigger types .......................................................................... Start Trigger, Pause Trigger, Script Trigger <0..3> (generation sessions only)  
Reference Trigger (acquisition sessions only)  
Multirecord Advance Trigger (acquisition sessions only)  
Sources .................................................................................. 1. PFI <0> (SMB jack connector)  
2. PFI <1..3> (DDC connector)  
3. PXI_TRIG<0..7> (PXI backplane, PXI only), RTSI <0..7> (PCI only)  
4. PXI_STAR (PXI backplane, PXI only)  
5. Pattern match (acquisition sessions only)  
6. Software (user function call)  
7. Disabled (do not wait for a trigger)  
Trigger detection.................................................................... 1. Start Trigger (edge detection: rising or falling)  
2. Pause Trigger (level detection: high or low)  
3. Script Trigger <0..3> (edge detection: rising or falling, Level detection: high or low)  
4. Reference Triggers (edge detection: rising or falling)  
5. Advance Trigger (edge detection)  
Minimum required trigger pulse width ................................. 30 ns  
Destinations........................................................................... 1. PFI 0 (SMB jack connector)  
2. PFI <1..3> (DDC connector)  
3. PXI_TRIG <0..7> (PXI backplane, PXI only), RTSI <0..7> (PCI only)  
Each of the triggers can be routed to any of the 13 destinations  
except the pause trigger cannot be exported.  
BUY ONLINE at ni.com or CALL (866) 265 9891 (U.S.)  
4
100 and 50 MHz, Programmable-Voltage  
Digital Waveform Generator/Analyzers  
Events (outputs from the NI 655x)  
Event types............................................................................. Marker <0..3>, Data Active event, Ready for Start event  
Destinations........................................................................... 1. PFI 0 (SMB jack connectors)  
2. PFI <1..3> (DDC connector)  
3. PXI_TRIG <0..7> (PXI backplane)  
Each of the events can be routed to any of the destinations with the exception of the  
Data Active event. The Data Active event can only be routed to the PFI channels.  
Miscellaneous  
Interval for external calibration............................................. 2 years  
Onboard Clock Characteristics (only valid when PLL reference source is set to “None”)  
Frequency accuracy................................................................ 100 ppm (typical)  
Temperature stability............................................................. 30 ppm (typical)  
Aging...................................................................................... 5 ppm first year (typical)  
Power Requirements  
Typical .................................................................................... 21.6 W  
Maximum ............................................................................... PXI: 26.5 W; PCI: 27 W  
Physical  
Dimensions ............................................................................ PXI: Single 3U CompactPCI Slot. PXI Compatible  
PCI: 12.6 by 35.5 cm (4.95 by 13.9 in.)  
Environment  
I/O Panel Connectors  
Label  
External Function(s)  
Connector Type  
CLK IN  
Sample Clock, External PLL  
Reference Input  
SMB jack  
PFI 0  
Events, Triggers  
SMB jack  
SMB jack  
CLK OUT  
Exported Sample Clock,  
Exported Reference Clock  
Digital Data and  
Control (DDC)  
Digital Data Channels, Exported  
Sample Clock, STROBE, Events, Triggers  
68-pin VHDCI  
Operating temperature .......................................................... PXI: 0 to 55 °C in all NI PXI chassis except the following. 0 to 45 °C when installed  
in an NI PXI-1000/B and PXI-101x chassis (meets IEC-60068-2-1 and IEC-60068-2-2).  
PCI: 0 to 45 °C  
Storage temperature.............................................................. -20 to 70 °C  
Relative humidity................................................................... 10 to 90% relative humidity, noncondensing (meets IEC-60068-2-56)  
Storage relative humidity ...................................................... 5 to 95% relative humidity, noncondensing (meets IEC-60068-2-56)  
Certifications and Compliance  
Safety  
NI 655x devices meet the requirements of the following standards for safety and electrical equipment for measurement, control,  
and laboratory use: IEC 61010-1, EN 61010-1, UL 61010B-1, CAN/CSA C22.2 No. 61010-1  
EMC ....................................................................................... Emissions: EN 55011 Class A at 10 m. FCC Part 15A above 1 GHz Immunity:  
EN 61326:1997 + A2:2001, Table 1, CE, C-Tick, and FCC Part 15 (Class A) Compliant  
BUY ONLINE at ni.com or CALL (866) 265 9891 (U.S.)  
5
NI Services and Support  
NI has the services and support to meet  
your needs around the globe and through  
the application life cycle – from planning  
and development through deployment  
and ongoing maintenance. We offer  
services and service levels to meet  
customer requirements in research,  
design, validation, and manufacturing.  
Visit ni.com/services.  
Local Sales and Technical Support  
In offices worldwide, our staff is local to the country, giving you access  
to engineers who speak your language. NI delivers industry-leading  
technical support through online knowledge bases, our applications  
engineers, and access to 14,000 measurement and automation  
professionals within NI Developer Exchange forums. Find immediate  
answers to your questions at ni.com/support.  
SERVICE  
NEEDS  
We also offer service programs that provide automatic upgrades to  
your application development environment and higher levels of technical  
support. Visit ni.com/ssp.  
Training and Certification  
NI training is the fastest, most certain route to productivity with our  
products. NI training can shorten your learning curve, save development  
time, and reduce maintenance costs over the application life cycle. We  
schedule instructor-led courses in cities worldwide, or we can hold a  
course at your facility. We also offer a professional certification program  
Hardware Services  
NI Factory Installation Services  
NI Factory Installation Services (FIS) is the fastest and easiest way to  
use your PXI or PXI/SCXI combination systems right out of the box.  
that identifies individuals who have high levels of skill and knowledge on Trained NI technicians install the software and hardware and configure  
using NI products. Visit ni.com/training.  
the system to your specifications. NI extends the standard warranty by  
one year on hardware components (controllers, chassis, modules)  
purchased with FIS. To use FIS, simply configure your system online with  
Professional Services  
Our Professional Services Team is comprised of NI applications engineers, ni.com/pxiadvisor.  
NI Consulting Services, and a worldwide National Instruments Alliance  
Calibration Services  
Partner program of more than 600 independent consultants and  
integrators. Services range from  
start-up assistance to turnkey  
NI recognizes the need to maintain properly calibrated devices for  
high-accuracy measurements. We provide manual calibration  
procedures, services to recalibrate your products, and automated  
calibration software specifically designed for use by metrology  
laboratories. Visit ni.com/calibration.  
system integration.  
Visit ni.com/alliance.  
OEM Support  
We offer design-in consulting and product integration assistance if you  
want to use our products for OEM applications. For information about  
special pricing and services for OEM customers, visit ni.com/oem.  
Repair and Extended Warranty  
NI provides complete repair services for our products. Express repair  
and advance replacement services are also available. We offer  
extended warranties to help you meet project life-cycle requirements.  
Visit ni.com/services.  
ni.com • (800) 813 3693  
National Instruments • info@ni.com  
© 2005 National Instruments Corporation. All rights reserved. CVI, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, RTSI, SCXI,  
and SignalExpress are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.  
A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.  
2005-5822-101  

相关型号:

NIPCI-6552

100 MHz Logic Analyzer/Digital Pattern Generators
NI

NIPCI-6561

400 and 200 Mb/s LVDS Digital Waveform Generator/Analyzers
NI

NIPCI-6562

400 and 200 Mb/s LVDS Digital Waveform Generator/Analyzers
NI

NIPCI-6601

32-Bit Counter/Timers
NI

NIPCI-6602

32-Bit Counter/Timers
NI

NIPCI-6624

Industrial, Channel-Channel Isolated,32-Bit Counter/Timers
NI

NIPCI-6703

Software-Timed Analog Output-16-Bit, 16 or 32 Channels
NI

NIPCI-6704

Software-Timed Analog Output-16-Bit, 16 or 32 Channels
NI

NIPCI-6711

High-Speed Voltage Output - up to 1 MS/s/Channel,up to 16 Bits, up to 32 Channels
NI

NIPCI-6713

High-Speed Voltage Output - up to 1 MS/s/Channel,up to 16 Bits, up to 32 Channels
NI

NIPCI-67221

High-Speed Voltage Output - up to 1 MS/s/Channel,up to 16 Bits, up to 32 Channels
NI

NIPCI-67231

High-Speed Voltage Output - up to 1 MS/s/Channel,up to 16 Bits, up to 32 Channels
NI