NIPCI-6551 [NI]
100 and 50 MHz, Programmable-Voltage Digital Waveform Generator/Analyzers; 100和50 MHz的可编程电压数字波形发生器/分析仪型号: | NIPCI-6551 |
厂家: | National Instruments |
描述: | 100 and 50 MHz, Programmable-Voltage Digital Waveform Generator/Analyzers |
文件: | 总6页 (文件大小:548K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
100 and 50 MHz, Programmable-Voltage
Digital Waveform Generator/Analyzers
NI 655x
• 100 MHz maximum clock rate
Operating Systems
• Windows 2000/NT/XP
• LabVIEW Real-Time
• -2.0 to 5.5 V programmable voltage
levels in 10 mV steps
• 20 channels with per-channel, per-cycle
bidirectional control
• 1, 8, or 64 Mb/channel onboard memory
• Real-time hardware comparison of
acquired data
Recommended Software
• LabVIEW
• LabWindows/CVI
• SignalExpress
• Complex triggering and pattern
sequencing
• Interactive waveform and script
editor software
• Synchronization and Memory Core
(SMC) for tight synchronization with
other SMC-based devices
Driver and Editing Software
(included)
• NI-HSDIO driver
• Script Editor
• Digital Waveform Editor
(included with 8 and
64 Mb/channel models)
Calibration
• NIST traceable
• 2-year external calibration cycle
Maximum Clock
Rate (MHz)
Memory
(Mb/channel) (Linking/Looping)
Scripting
Programmable Per-Cycle
Hardware
Comparison
Product Platform
Channels
Voltage Levels
Data Delay
Tristate
NI 6552
NI 6551
PCI, PXI
PCI, PXI
20
20
100
50
Programmable, 10 mV steps
Programmable, 10 mV steps
1, 8, or 64
1, 8, or 64
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Table 1. NI 655x Selection Guide
Overview
Design High-Performance Tests
For building high-performance stimulus-response systems, the NI 655x
The National Instruments 6552 and
6551 are 100 and 50 MHz digital
waveform generator/analyzers,
respectively, for characterizing,
validating, and testing digital
Applications
Semiconductor
devices include:
• A sophisticated timing engine to adjust for the timing parameters
of the device under test
Mixed-signal design validation and test
Interfacing to digital electronics
Aerospace/Defense
Subsystem emulation
• Programmable voltage levels for testing multiple devices or
characterizing a single device under changing conditions
• Per-cycle tristate for bidirectional communication
• A versatile memory architecture for maximum flexibility of waveform
and scripting memory
Bit error rate tester (BERT)
electronics. These modules feature
20 channels with per-channel,
Communications
Multimedia chipset emulation
per-cycle direction control and deep
onboard memory with triggering and
pattern sequencing. You can program
the voltage levels on NI 655x devices
Consumer Electronics
CMOS and CCD imaging sensors
Digital display tests
The hardware architecture is designed to preserve high signal quality,
and an eye diagram of the PXI-6552 generation is shown in Figure 1.
You can use the internal clock or an external clock, such as from the
NI PXI-5404, through the front panel. You can also shift the data
generated, data acquired, and exported sample clock relative to the
onboard clock for clock frequencies above 25 MHz, which is critical to
adjust for propagation delays and setup-and-hold times in the device
under test.
with 10 mV resolution. You can use them with the NI Digital Waveform
Editor, an interactive software tool for creating, editing, and importing
digital waveforms. With the SMC, you can create mixed-signal test
systems with digitizers, arbitrary waveform generators, and other digital
waveform generator/analyzers, or you can synchronize multiple digital
waveform devices to build high-channel-count test systems.
Programmable voltage levels are needed when testing different
devices or when characterizing how a given device performs under
changing conditions. With NI 655x devices, the high and low levels for
100 and 50 MHz, Programmable-Voltage
Digital Waveform Generator/Analyzers
acquisition and generation can be set independently. You can program
the voltage levels between -2.0 and 5.5 V with 10 mV resolution for TTL,
LVTTL, LVCMOS, ECL, PECL, and other signal level compatibility.
The SMC memory architecture is designed for maximum flexibility
between waveform memory and scripting memory, the instructions for
pattern linking and looping. Using a single memory bank, you can
allocate as much memory as needed for script and waveform data, giving
you maximum flexibility from test to test.
Driver Software
NI 655x devices include the NI-HSDIO driver with an intuitive, powerful
API based on IVI guidelines. The Windows-compatible NI-HSDIO driver
provides an API for LabVIEW, SignalExpress, LabWindows/CVI, and other
text-based development environments.
Figure 1. Eye Diagram of NI PXI-6552 Generation
Create Digital Waveforms Interactively
with the Digital Waveform Editor
Figure 2. Digital Waveform Editor with ASCII and VCD Import Wizards
With the NI Digital Waveform Editor, an interactive software tool for
creating and editing digital waveforms, you can import existing test
patterns from popular spreadsheet and VHDL simulation packages in
ASCII or value change dump (VCD) formats. Once imported, you can view
the waveforms graphically and edit them interactively for new devices or
new test conditions. You can also build new waveforms with built-in fill
patterns such as pseudorandom bit sequences (PRBS) and count
up/down patterns. When ready to test your device, the waveforms import
seamlessly into NI LabVIEW, SignalExpress, and C. The Digital Waveform
Editor is included with the 8 and 64 Mb/channel memory models, and is
a separate add-on for use with the 1 Mb/channel model.
Ordering Information
NI PCI-6551 ................................................................778950-0M1
NI PCI-6552 ................................................................778951-0M1
NI PXI-6551 ................................................................778538-0M1
NI PXI-6552 ................................................................778539-0M1
1Where M is: 1 (1 Mb/channel), 2 (8 Mb/channel), or 3 (64 Mb/channel)
Includes NI 655x device and NI-HSDIO driver. The 8 and 64 Mb/channel models also
include the Digital Waveform Editor.
Software
NI Digital Waveform Editor ..........................................778724-03
Build Tightly Synchronized Mixed-Signal Test Systems
NI 655x devices use the same SMC architecture as the NI 5122 high-
resolution digitizers and NI 5441 arbitrary waveform generators, so you
can combine these devices to build tightly synchronized mixed-signal
prototyping and test systems. For tight timing requirements, these PXI
modules phase-lock to the 10 MHz reference clock on the PXI backplane.
If you have an external precision reference, you can import it through the
front panel SMB connector.
Cable
SHC68-C68-D2 ..............................................................188142-01
SHC68-HIX38 ..............................................................192681-1R5
Accessories
CB-2162 ........................................................................778592-01
SMB-2163......................................................................778749-01
BUY NOW!
For complete product specifications, pricing, and accessory
information, call (800) 813 3693 (U.S. only) or go to ni.com.
BUY ONLINE at ni.com or CALL (866) 265 9891 (U.S.)
2
100 and 50 MHz, Programmable-Voltage
Digital Waveform Generator/Analyzers
Specifications
These specifications are valid for the following temperature ranges: PXI: 0 to 55 °C, PCI: 0 to 45 °C.
Channel Characteristics
Number of data channels ...................................................... 20
Direction control of data channels........................................ Per-channel, per-cycle
Generation Signal Characteristics (data, DDC ClkOut, and PFI <0..3> channels)
All voltage ranges specified into 1 M
Ω
Generation voltage range...................................................... -2.0 to 5.5 V
Generation signal type .......................................................... Single-ended
Number of programmable voltage levels.............................. 1 voltage low level and 1 voltage high level applies to all data,
Clk Out (sample clock only), and PFI channels
Generation voltage range restrictions................................... -0.5 to 5.5 V (up to 50 MHz clock rate)
-2 to 3.7 V (up to 50 MHz clock rate)
-0.5 to 3.7 V (50 to 100 MHz clock rate; NI 6552 only)
Generation voltage swing ..................................................... 400 mV to 6 V (up to 50 MHz clock rate)
400 mV to 4.2 V (50 to 100 MHz clock rate; NI 6552 only)
Generation voltage-level resolution...................................... 10 mV
DC generation voltage-level accuracy................................... 20 mV (excluding system crosstalk)
Output impedance.................................................................. 50
Maximum DC drive strength.................................................. 50 mA maximum per channel
600 mA maximum for all data, clock, and PFI channels
Channel power-up state ........................................................ Drivers disabled, 10 k input impedance
Ωnominal at 25 °C
Ω
Acquisition Signal Characteristics (data, strobe, and PFI <0..3> channels)
Acquisition voltage range...................................................... -2.0 V to 5.5 V
Number of programmable acquisition thresholds ................ 1 voltage low threshold and a strobe voltage high threshold applies to all data
and PFI channels
Minimum detectable voltage swing...................................... 50 mV
Acquisition voltage threshold resolution .............................. 10 mV
DC acquisition voltage threshold accuracy........................... 30 mV (excluding system crosstalk)
Input impedance .................................................................... 50
Ω
or 10 kΩ(default), software-selectable per channel;
applies when powered on and within valid voltage range
Timing Characteristics
Sample Clock
Sample clock sources ............................................................ 1. Onboard clock (internal VCXO with divider)
2. CLK IN (SMB jack connector)
3. PXI_STAR (PXI backplane; PXI only)
4. STROBE (DDC Connector) – Acquisition only
Onboard clock frequency range ............................................ NI 6551: 48 Hz to 50 MHz. (settable to 200 MHz/N; 4
NI 6552: 48 Hz to 100 MHz (settable to 200 MHz/N; 2
≤
N
≤
4,194,304)
≤N ≤4,194,304)
Exported sample clock delay range....................................... 0 to 1 sample clock periods for clock frequencies
≥25 MHz
Exported sample clock delay resolution................................ 1/256 of sample clock period for clock frequencies
≥25 MHz
Exported Sample Clock Jitter (typical using onboard clock)
Period jitter
Cycle-to-cycle jitter
20 ps (rms)
35 ps (rms)
BUY ONLINE at ni.com or CALL (866) 265 9891 (U.S.)
3
100 and 50 MHz, Programmable-Voltage
Digital Waveform Generator/Analyzers
Generation Signal Characteristics (data, DDC Clk Out, and PFI <0..3> channels)
Data channel-to-channel skew.............................................. 300 ps (typical across all data channels)
900 ps (maximum across all data channels)
Maximum data channel toggle rate...................................... NI 6551: 25 MHz; NI 6552: 50 MHz
Data formats.......................................................................... NRZ
Data position modes.............................................................. Rising edge, falling edge, delayed relative to sample clock
Generation data delay range................................................. 0 to 1 sample clock period for clock frequencies
≥25 MHz
Generation data delay resolution.......................................... 1/256 of sample clock period for clock frequencies
≥25 MHz
Acquisition Signal Characteristics (data, strobe, and PFI <0..3> channels)
Channel-to-channel skew...................................................... 400 ps (typical across all data channels)
900 ps (maximum across all data channels)
Minimum detectable pulse width ......................................... 4 ns (required at both acquisition voltage thresholds)
Acquisition timing delay range.............................................. 0 to 1 sample clock periods for clock frequencies 25 MHz
25 MHz
≥
Acquisition timing delay resolution....................................... 1/256 of sample clock period for clock frequencies
≥
Waveform Characteristics
Memory and Scripting
Onboard memory size
(assumes no scripting
instructions)
1 Mb/channel
(for generation sessions)
8 Mb/channel
(for generation sessions)
64 Mb/channel
(for generation sessions)
1 Mb/channel
8 Mb/channel
64 Mb/channel
(for acquisition sessions)
(for acquisition sessions)
(for acquisition sessions)
Generation Modes
Waveform: Generate a single waveform once, N times, or continuously.
Scripted: Generate a simple or complex sequence of waveforms. Use scripts to describe the waveforms to be generated,
the order in which the waveforms are generated, how many times the waveforms are generated, and how the device
responds to script triggers.
Triggers (inputs to the NI 655x)
Trigger types .......................................................................... Start Trigger, Pause Trigger, Script Trigger <0..3> (generation sessions only)
Reference Trigger (acquisition sessions only)
Multirecord Advance Trigger (acquisition sessions only)
Sources .................................................................................. 1. PFI <0> (SMB jack connector)
2. PFI <1..3> (DDC connector)
3. PXI_TRIG<0..7> (PXI backplane, PXI only), RTSI <0..7> (PCI only)
4. PXI_STAR (PXI backplane, PXI only)
5. Pattern match (acquisition sessions only)
6. Software (user function call)
7. Disabled (do not wait for a trigger)
Trigger detection.................................................................... 1. Start Trigger (edge detection: rising or falling)
2. Pause Trigger (level detection: high or low)
3. Script Trigger <0..3> (edge detection: rising or falling, Level detection: high or low)
4. Reference Triggers (edge detection: rising or falling)
5. Advance Trigger (edge detection)
Minimum required trigger pulse width ................................. 30 ns
Destinations........................................................................... 1. PFI 0 (SMB jack connector)
2. PFI <1..3> (DDC connector)
3. PXI_TRIG <0..7> (PXI backplane, PXI only), RTSI <0..7> (PCI only)
Each of the triggers can be routed to any of the 13 destinations
except the pause trigger cannot be exported.
BUY ONLINE at ni.com or CALL (866) 265 9891 (U.S.)
4
100 and 50 MHz, Programmable-Voltage
Digital Waveform Generator/Analyzers
Events (outputs from the NI 655x)
Event types............................................................................. Marker <0..3>, Data Active event, Ready for Start event
Destinations........................................................................... 1. PFI 0 (SMB jack connectors)
2. PFI <1..3> (DDC connector)
3. PXI_TRIG <0..7> (PXI backplane)
Each of the events can be routed to any of the destinations with the exception of the
Data Active event. The Data Active event can only be routed to the PFI channels.
Miscellaneous
Interval for external calibration............................................. 2 years
Onboard Clock Characteristics (only valid when PLL reference source is set to “None”)
Frequency accuracy................................................................ 100 ppm (typical)
Temperature stability............................................................. 30 ppm (typical)
Aging...................................................................................... 5 ppm first year (typical)
Power Requirements
Typical .................................................................................... 21.6 W
Maximum ............................................................................... PXI: 26.5 W; PCI: 27 W
Physical
Dimensions ............................................................................ PXI: Single 3U CompactPCI Slot. PXI Compatible
PCI: 12.6 by 35.5 cm (4.95 by 13.9 in.)
Environment
I/O Panel Connectors
Label
External Function(s)
Connector Type
CLK IN
Sample Clock, External PLL
Reference Input
SMB jack
PFI 0
Events, Triggers
SMB jack
SMB jack
CLK OUT
Exported Sample Clock,
Exported Reference Clock
Digital Data and
Control (DDC)
Digital Data Channels, Exported
Sample Clock, STROBE, Events, Triggers
68-pin VHDCI
Operating temperature .......................................................... PXI: 0 to 55 °C in all NI PXI chassis except the following. 0 to 45 °C when installed
in an NI PXI-1000/B and PXI-101x chassis (meets IEC-60068-2-1 and IEC-60068-2-2).
PCI: 0 to 45 °C
Storage temperature.............................................................. -20 to 70 °C
Relative humidity................................................................... 10 to 90% relative humidity, noncondensing (meets IEC-60068-2-56)
Storage relative humidity ...................................................... 5 to 95% relative humidity, noncondensing (meets IEC-60068-2-56)
Certifications and Compliance
Safety
NI 655x devices meet the requirements of the following standards for safety and electrical equipment for measurement, control,
and laboratory use: IEC 61010-1, EN 61010-1, UL 61010B-1, CAN/CSA C22.2 No. 61010-1
EMC ....................................................................................... Emissions: EN 55011 Class A at 10 m. FCC Part 15A above 1 GHz Immunity:
EN 61326:1997 + A2:2001, Table 1, CE, C-Tick, and FCC Part 15 (Class A) Compliant
BUY ONLINE at ni.com or CALL (866) 265 9891 (U.S.)
5
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
SERVICE
NEEDS
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
that identifies individuals who have high levels of skill and knowledge on Trained NI technicians install the software and hardware and configure
using NI products. Visit ni.com/training.
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online with
Professional Services
Our Professional Services Team is comprised of NI applications engineers, ni.com/pxiadvisor.
NI Consulting Services, and a worldwide National Instruments Alliance
Calibration Services
Partner program of more than 600 independent consultants and
integrators. Services range from
start-up assistance to turnkey
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • (800) 813 3693
National Instruments • info@ni.com
© 2005 National Instruments Corporation. All rights reserved. CVI, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, RTSI, SCXI,
and SignalExpress are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.
A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
2005-5822-101
相关型号:
©2020 ICPDF网 联系我们和版权申明