USB-9472 [NI]

Portable USB-Based High-Voltage Digital I/O; 基于USB的便携式高压数字I / O
USB-9472
型号: USB-9472
厂家: National Instruments    National Instruments
描述:

Portable USB-Based High-Voltage Digital I/O
基于USB的便携式高压数字I / O

高压 便携式
文件: 总2页 (文件大小:185K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Portable USB-Based  
High-Voltage Digital I/O  
NI USB-9421, NI USB-9472, NI USB-9481 NEW!  
• Small, portable devices  
Operating Systems  
(12.1 by 8.6 by 2.5 cm)  
• 4 or 8 channels with 24 V  
logic levels  
• High current-switching capacity  
• 250 Vrms channel-to-earth  
ground isolation  
• Plug-and-play connectivity  
via USBs  
• Screw-terminal and D-Sub  
connectors for direct wiring to  
industrial sensors and actuators  
• Windows 2000/XP  
Recommended Software  
• LabVIEW  
• LabWindows/CVI  
Measurement Services  
Software (included)  
• NI-DAQmx driver software  
• VI Logger Lite data-logging  
software  
Driver Software1  
NI-DAQmx  
NI-DAQmx  
Product  
Bus  
USB  
USB  
USB  
Input Lines  
8 sink  
Output Lines  
8 source  
Isolation  
Bank  
Bank  
Signal Levels  
11 to 30 V  
6 to 30 V  
60 VDC  
250 VAC/VDC  
Output Current per Channel  
Connector  
USB-9421  
USB-9472  
USB-9481  
Screw Terminal, D-Sub  
Screw Terminal, D-Sub  
Screw Terminal  
0.75 A  
2 A (30 VDC)  
1 A (60 VDC)  
4 Form A Relay  
Bank  
NI-DAQmx  
1For up-to-date information on NI-DAQ, visit ni.com/support/daq/versions.htm.  
Table 1. Portable USB DAQ for High-Voltage Digital I/O Selection Guide  
Hardware Description  
Common Applications  
National Instruments USB-9421, USB-9472, and USB-9481 are data The USB-9421, USB-9472, and USB-9481 are ideal for monitoring  
acquisition modules with integrated signal conditioning. They and control applications where easy connectivity and portability are  
provide plug-and-play connectivity via USB for faster setup and essential, such as:  
measurements, offering four or eight digital input or output channels • Portable industrial monitoring and controlling motors, fans,  
specifically designed for monitoring and control applications. The  
pumps, relays, and limit switches  
NI USB-9421 digital input module accepts high-voltage levels • Data logging  
between 11 and 30 V for direct connection to 24 V systems. The • Small form-factor applications  
NI USB-9472 can source up to 30 V externally powered at 0.75 A of • Embedded OEM applications  
current per channel, and the NI USB-9481 uses electromechanical • In-vehicle data acquisition  
relays that can switch 2 A at 30 VDC and 1 A at 60 VDC. In addition, • Academic lab use  
these modules include channel-to-earth ground isolation for safety,  
noise immunity and high common-mode voltage range.  
Information for OEM Customers  
For information on special configurations and pricing, please  
Software Description  
visit ni.com/oem.  
The USB-9421, USB-9472, and USB-9481 all use NI-DAQmx  
high-performance, multithreaded driver software for interactive  
configuration and data acquisition on Windows OSs. Use  
NI-DAQmx to test channels, generate code, and apply custom  
functionality to any of your measurements. All NI data acquisition  
devices shipped with NI-DAQmx also include VI Logger Lite  
configuration-based data-logging software.  
Ordering Information  
NI USB-9421  
Screw Terminals ........................................................779451-01  
D-Sub Connector......................................................779452-01  
NI USB-9472  
Screw Terminals ........................................................779449-01  
D-Sub Connector......................................................779450-01  
NI USB-9481 ................................................................779453-01  
Accessories  
Recommended Accessories  
NI 9934 ......................................................................779104-01  
The USB-9421, USB-9472, and USB-9481 all have built-in screw-  
terminal connectivity, so no additional accessories are required. The  
USB-9421 and USB-9472 are also available with D-Sub connector  
options that connect to the NI 9934 strain relief accessory, or any  
other standard 25-pin D-Sub connector.  
BUY NOW!  
For complete product specifications, pricing, and accessory  
information, call (800) 813 3693 (U.S. only) or go to ni.com/oem.  
NI Services and Support  
NI has the services and support to meet your  
needs around the globe and through the  
application life cycle – from planning  
and development through deployment  
Local Sales and Technical Support  
In offices worldwide, our staff is local to the country, giving you  
access to engineers who speak your language. NI delivers industry-  
leading technical support through online knowledge bases, our  
applications engineers, and access to 14,000 measurement and  
automation professionals within NI Developer Exchange forums.  
Find immediate answers to your questions at ni.com/support.  
We also offer service programs that provide automatic upgrades to  
your application development environment and higher levels of  
technical support. Visit ni.com/ssp.  
and ongoing maintenance. We offer  
services and service levels to meet  
customer requirements in research,  
design, validation, and manufacturing.  
Visit ni.com/services.  
SERVICE  
NEEDS  
Training and Certification  
NI training is the fastest, most certain route to productivity with our Hardware Services  
products. NI training can shorten your learning curve, save NI Factory Installation Services  
development time, and reduce maintenance costs over the NI Factory Installation Services (FIS) is the fastest and easiest way to  
application life cycle. We schedule instructor-led courses in cities use your PXI or PXI/SCXI combination systems right out of the box.  
worldwide, or we can hold a course at your facility. We also offer a Trained NI technicians install the software and hardware and  
professional certification program that identifies individuals who configure the system to your specifications. NI extends the standard  
have high levels of skill and knowledge on using NI products. warranty by one year on hardware components (controllers, chassis,  
Visit ni.com/training.  
modules) purchased with FIS. To use FIS, simply configure your  
system online with ni.com/pxiadvisor.  
Professional Services  
Our Professional Services Team is comprised of NI applications Calibration Services  
engineers, NI Consulting Services, and a worldwide National Instruments NI recognizes the need to maintain properly calibrated devices for  
Alliance Partner program of more than 600 independent consultants high-accuracy measurements. We provide manual calibration  
and integrators. Services procedures, services to recalibrate your products, and automated  
range from start-up assistance calibration software specifically designed for use by metrology  
to turnkey system integration. laboratories. Visit ni.com/calibration.  
Visit ni.com/alliance.  
Repair and Extended Warranty  
OEM Support  
NI provides complete repair services for our products. Express repair  
We offer design-in consulting and product integration assistance and advance replacement services are also available. We offer  
if you want to use our products for OEM applications. For extended warranties to help you meet project life-cycle requirements.  
information about special pricing and services for OEM customers, Visit ni.com/services.  
visit ni.com/oem.  
ni.com • (800) 813 3693  
National Instruments • info@ni.com  
© 2005 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner,  
NI, ni.com, NI-DAQ, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective  
companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.  

相关型号:

USB-9481

Portable USB-Based High-Voltage Digital I/O

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
NI

USB-9AB-080-28N-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AB-080-28S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AB-130-26S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AB-200-24S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AB-300-22N-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AB-300-22S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AB-500-20N-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AO-080-28N-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AO-080-28S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AO-130-26S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT

USB-9AO-200-24S-MO1

Interconnection Device

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ITT