CGD2.5K-24-220 [NOVA]

PURE-SINEWAVE DC-AC INVERTERS;
CGD2.5K-24-220
型号: CGD2.5K-24-220
厂家: Nova Electric    Nova Electric
描述:

PURE-SINEWAVE DC-AC INVERTERS

文件: 总2页 (文件大小:494K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CGD2.5K SERIES  
PURE-SINEWAVE DC-AC INVERTERS  
» INCLUDES BUILT-IN AUT
TRANSFER SWITCH (ATS) W
INPUT CIRCUIT BREAKER  
» PARALLELABLE FOR INC
POWER  
» 3 PHASE WYE CONFIGUR
» 120/240 CT SPLIT PHASE  
CONFIGURABLE  
APPLICATIONS  
Nova Electric’s CGD-Series inverters are intended for commercial and industrial applications wherever  
pure sinewave power is needed at 50 or 60 Hz. These inverters are ideal for running electronic loads  
such as computers, monitors, printers, telecom systems, radios, fluorescent lamps from batteries,  
field generators, and solar electro-voltaic panels. They can also drive hand drills, motors and small  
compressors – please consult the factory for proper sizing. These CGD models can also be optionally  
ruggedized against shock, vibration, and humidity for military applications including vehicle mounted,  
shipboard, submarine, aircraft, and ground fixed shelters.  
COMPUTERS  
PRINTERS  
SAIL BOATS  
APPLIANCES  
INSTRUMENTS  
RVs  
q
q
q
q
q
q
q
q
q
PHOTO VOLTAIC  
ELECTRIC TOOLS  
MONITORS  
For more information, please visit us at www.novaelectric.com or email us at novasales@theallpower.com  
STANDARD FEATURES  
ELECTRICAL  
SAFETY & EMC  
120V: UL458*; FCC Class B  
220V: EN60950-1; EN55014-1**, EN55014-2**;  
EN61000-3-2, -3-3; EN61204-3;  
EN61000-6-1, -6-2, -6-3, -6-4;  
Microprocessor based design with absolutely Input Voltage: See Table  
accurate and stable frequency.  
Output Voltage 110V model: 100/110/120 VAC  
Output Voltage 220V model: 220/230/240 VAC  
Output Frequency: 50 or 60 HZ 0.1ꢀ Accuracy  
Continuous Power Rating: 2500W/2500VA  
Peak Power (3 seconds): 3000W  
Compact and light weight, yet rugged and  
vehicle rated.  
IEC61000-4-2, 3,4,5,6,8,11  
Tightly regulated output voltage and frequency  
Switch selectable 50 or 60 Hz output, all models  
Capable of driving highly reactive loads such as  
electric tools and appliances.  
ENVIRONMENTAL  
Surge Rating: 4000Wz  
Operating Temp.: -20° to +40°; + 60°C @ 40ꢀ Pwr Load  
Storage Temp. Range: -40° to +71°C  
Humidity: To 90ꢀ non-condensing  
Efficiency: 88ꢀ (12V), 89ꢀ (24V), 90ꢀ (48V)  
Output Waveform Sinewave: <3ꢀ THD  
Output Voltage Regulation: 3ꢀ  
Protection: Overload, Short Circuit, Reverse Polarity  
(Fuse), O.T, Over/Under Input Voltage, Fan Failure  
Output Frequency Regulation: 0.1ꢀ  
Capable of driving highly capacitive loads such  
as switching power supplies.  
INDICATORS, CONTROL & COMMUNICATIONS  
Input level, Fault Status  
Very low harmonic distortion  
Optional Remote Control  
Suitable for vehicle or wall mounting  
Standard outputs 110V/60Hz, 230V/50Hz  
Switch selectable 10V output change  
RS-232 communication (RJ11 Connector)  
Built in mechanical transfer switch (ATS)  
Optional Ethernet Communications  
Synchronous Frequency: 47-57 / 53 - 63 Hz  
ATS: Inverter to utility AC: 8 ~ 10ms.  
Utility AC to inverter: 16 ~ 50 ms.  
* UL-458 only support CGD2500W-12-120 and CGD2500W-24-120  
** EN55014-1, EN55014-2 Class B: output cable less than 6.5 ft (2 meters)  
12V - 120V  
24V - 120V  
48V - 120V  
12V - 220V  
24V - 220V  
48V - 220V  
No Load Power Consumption  
@12VDC  
@24VDC  
@48VDC  
@12VDC  
@24VDC  
@48VDC  
On Mode @ Save Mode  
On Mode @ No Load Mode  
0.9A  
<2.9A  
0.35A  
<1.4A  
0.3A  
<0.8A  
1.1A  
<3.6A  
0.7A  
<1.8A  
0.4A  
<1A  
Fuse  
40A x 9  
10.5 VDC  
10.0 VDC  
12.5 VDC  
15.5 VDC  
16.0 VDC  
15.0 VDC  
20A x 9  
21.0 VDC  
20.0 VDC  
25.0 VDC  
31.0 VDC  
32.0 VDC  
30.0 VDC  
15A x 6  
42.0 VDC  
40.0 VDC  
50.0 VDC  
62.0 VDC  
64.0 VDC  
60.0 VDC  
40A x 9  
10.5 VDC  
10.0 VDC  
12.5 VDC  
15.5 VDC  
16.0 VDC  
15.0 VDC  
20A x 9  
21.0 VDC  
20.0 VDC  
25.0 VDC  
31.0 VDC  
32.0 VDC  
30.0 VDC  
15A x 6  
42.0 VDC  
40.0 VDC  
50.0 VDC  
62.0 VDC  
64.0 VDC  
60.0 VDC  
BAT. Low Alarm 3ꢀ  
BAT. Low Shut-down 3ꢀ  
BAT. Low Restart 3ꢀ  
BAT. High Alarm 3ꢀ  
BAT. High Shut-down 3ꢀ  
BAT. High Restart 3ꢀ  
MODEL SELECTION  
INPUT  
VDC  
120 V MODELS  
220 V MODELS  
50 Hz or 60 Hz  
DIMENSIONS  
(L” x W” x H”) [mm]  
WEIGHT  
50 Hz or 60 Hz  
CGD2.5K-12-120  
CGD2.5K-24-120  
CGD2.5K-48-120  
10 - 16 V  
20 - 32 V  
40 - 60 V  
CGD2.5K-12-220  
CGD2.5K-24-220  
CGD2.5K-24-220  
17.17 x 11.14 x 5.04 [436 x 283 x 128]  
17.17 x 11.14 x 5.04 [436 x 283 x 128]  
17.17 x 11.14 x 5.04 [436 x 283 x 128]  
18 lbs [8 kg]  
18 lbs [8 kg]  
18 lbs [8 kg]  
MECHANICAL SPECIFICATIONS  
GROUND  
AS9100  
Leader in power conversion technology since 1966  
NOVA ELECTRIC  
Certiꢀcate No: US008267-1  

相关型号:

CGD2.5K-48-120

PURE-SINEWAVE DC-AC INVERTERS
NOVA

CGD3.5K

PURE-SINEWAVE DC-AC INVERTERS
NOVA

CGD3.5K-12-120

PURE-SINEWAVE DC-AC INVERTERS
NOVA

CGD3.5K-12-220

PURE-SINEWAVE DC-AC INVERTERS
NOVA

CGD3.5K-24-120

PURE-SINEWAVE DC-AC INVERTERS
NOVA

CGD3.5K-24-220

PURE-SINEWAVE DC-AC INVERTERS
NOVA

CGD3.5K-48-120

PURE-SINEWAVE DC-AC INVERTERS
NOVA

CGD888C

RF Manual 16th edition
NXP

CGD914

CATV amplifier module
NXP

CGD914,112

RF/Microwave Amplifier, 40 MHz - 870 MHz RF/MICROWAVE WIDE BAND HIGH POWER AMPLIFIER, SOT-115J, 7 PIN
NXP

CGD914MI

860 MHz, 20 dB gain power doubler amplifier
NXP

CGD914_01

860 MHz, 20 dB gain power doubler amplifier
NXP