OCGL2K-48-220 [NOVA]
DC-AC INVERTERS;型号: | OCGL2K-48-220 |
厂家: | Nova Electric |
描述: | DC-AC INVERTERS |
文件: | 总2页 (文件大小:724K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
RUGGED PORTABLE OUTDOOR
OCGL - SERIES
DC-AC INVERTERS
Input: 12, 24, or 48VDC
Outppuutt:: 120V or 220V 11ØØ
5500 oorr 6600HHzz
Poowweerr:: 2KW / 3KW
APPPLLICCATTIIOONNSS
Utilizing field proven technology, this family of rugged
pure sinewave DC-AC Inverters is suitable for harsh
environments and can be customized for unique
applications including:
NOVA ELECTRIC
www.novaelectric.com
novasales@theallpower.com
Military Shelters
Tactical Systems
Ground support
MIL-STD-810
Utility Applications
Mobile Systems
Communications
MIL-STD-461
A Leader in INVERTER Technology since 1966 - 500VA to 500+KVA
MADE IN USA
PURE SINEWAVE DC-AC INVERTER
SPECIFICATIONS
FEATURES
ELECTRICAL
ENVIRONMENTAL
Operating Temperature: -20°C to +50°C
Storage Temperature: -40°C to + 71°C
Shock: 20g / 11mS per MIL-STD-810
Vibration: per MIL-STD-810 (Munson
Road Test)
Humidity: per MIL-STD-810 to 95% non
condensing
EMI: per MIL-STD-461 CE102, CS101,
CS114, CS115, CS116, RE102, and RS103
Input Voltage: 12, 24 or 48 V
• Microprocessor based design with absolutely
accurate and stable frequency.
• Compact and light weight, yet rugged
and vehicle rated.
Output Voltage 110V model: 100/110/120 VAC
Output Voltage 220V model: 220/230/240 VAC
Output Frequency: 50 or 60 HZ
± 0.05% Accuracy
2KW Surge Rating: 4000W
3KW Surge Rating: 6000W
No load Current: <1.0W Sleep Mode
Output Waveform Sinewave: <3% THD
Output Regulation: -10% / +4% All models
MTBF: over 100,000 hours per field data
MTTR: 30 minutes
• 89-95% efficient.
• Tightly regulated output voltage and frequency
• Switch selectable 50 or 60 Hz output
• Capable of driving highly reactive loads such
as electric tools and appliances.
• Capable of driving highly capacitive loads
such as switching power supplies.
• Very low harmonic distortion, THD<3%.
• Suitable for vehicle or wall mounting.
• IP Rating: 54 (higher ratings optional)
PROTECTIVE FEATURES
Overload, Short Circuit, Reverse Polarity
(Fuse), O.T, Over/Under Input Voltage.
MODEL SELECTION
CONTINUOUS
OUTPUT POWER
SIZE (HxWxL)
(INCHES)
OUTPUT
APPROX.
WEIGHT (LB)
INPUT RANGE OUTPUT
MODEL
EFFICIENCY
(FULL LOAD)
FREQ. (HZ)
50 OR 60
50 OR 60
VDC
10.5-15
10.5-15
VDC
120
OCGL2K-12-120
OCGL2K-12-220
2KW
2KW
89%
29 LB
29 LB
6.8 x 10 x 17.9
6.8 x 10 x 17.9
220
91%
OCGL2K-24-120
OCGL3K-24-120
OCGL2K-24-220
OCGL3K-24-220
21-30
21-30
21-30
21-30
120
120
220
220
50 OR 60
50 OR 60
50 OR 60
50 OR 60
2KW
3KW
2KW
3KW
92%
91%
94%
93%
29 LB
34 LB
29 LB
34 LB
6.8 x 10 x 17.9
9 x 12 x 17.9
6.8 x 10 x 17.9
9 x 12 x 17.9
OCGL2K-48-120
OCGL3K-48-120
OCGL2K-48-220
OCGL3K-48-220
42-60
42-60
42-60
42-60
120
120
220
220
50 OR 60
50 OR 60
50 OR 60
50 OR 60
2KW
3KW
2KW
3KW
93%
92%
95%
94%
29 LB
34 LB
29 LB
34 LB
6.8 x 10 x 17.9
9 x 12 x 17.9
6.8 x 10 x 17.9
9 x 12 x 17.9
MECHANICAL SPECIFICATIONS
TYPICAL 2KW OUTLINE
(OPTIOONALL)
NOVA ELECTRIC
A Division of
WEB : www.novaelectric.com
TECHNOLOGY DYNAMICS, INC.
100 School St., Bergenfield NJ 07621
E-Mail : novasales@theallpower.com
PHONE : (201) 385-0500 FAX : (201) 385-0702
相关型号:
©2020 ICPDF网 联系我们和版权申明