LM41CIMT [NSC]
Hardware Monitor with Thermal Diode Inputs and SensorPath⑩ Bus; 硬件监控与热敏二极管输入和SensorPath⑩巴士型号: | LM41CIMT |
厂家: | National Semiconductor |
描述: | Hardware Monitor with Thermal Diode Inputs and SensorPath⑩ Bus |
文件: | 总27页 (文件大小:362K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
May 2004
LM41
Hardware Monitor with Thermal Diode Inputs and
™
SensorPath Bus
General Description
— Internal scaling resistors for all inputs
— Monitors +1.2V, +2.5 V, +3.3 V, +5 V and +12 V
The LM41 is a hardware monitor that measures 2 tempera-
ture zones, 5 voltages and has a single-wire interface com-
patible with National Semiconductor’s SensorPath bus. Sen-
sorPath data is pulse width encoded, thereby allowing the
LM41 to be easily connected to many general purpose
micro-controllers. Several National Semiconductor Super I/O
products include a fully integrated SensorPath master, that
when connected to the LM41 can realize a hardware monitor
function that includes limit checking for measured values,
autonomous fan speed control and many other functions.
n Temperature Sensing
— Remote diode temperature sensor zone
— Internal local temperature zone
— 0.5 ˚C resolution
— Measures temperatures up to 140 ˚C
n 14-lead TSSOP package
Key Specifications
n Voltage Measurement Accuracy
n Temperature Sensor Accuracy
n Temperature Range:
2 % (max)
3 ˚C (max)
The LM41 measures the temperature of its own die as well
as one external device such as a processor thermal diode or
a diode connected transistor. The LM41 can resolve tem-
peratures up to 255˚C and down to -256˚C. The operating
temperature range of the LM41 is 0˚C to +125˚C. Using Σ∆
ADC it measures +1.2V, +2.5V, +3.3V, +5V and +12V analog
input voltages with internal scaling resistors. The address
programming pin allows two LM41’s to be placed on one
SensorPath bus.
— LM41 junction
— Remote Temp Accuracy
n Power Supply Voltage
n Average Power Supply Current
n Conversion Time (all Channels)
0 ˚C to +85 ˚C
0 ˚C to +100 ˚C
+3.0 V to +3.6 V
0.5 mA (typ)
22.1ms to 1456ms
Applications
n Microprocessor based equipment
Features
(Motherboards, Video Cards, Base-stations, Routers,
ATMs, Point of Sale, …)
n Power Supplies
n
SensorPath Interface
— 2 hardware programmable addresses
n Voltage Monitoring
— 9-bit Σ∆ ADC
Typical Application
20070301
™
SensorPath is a trademark of National Semiconductor Corporation
© 2004 National Semiconductor Corporation
DS200703
www.national.com
Connection Diagram
NS
Order
Number
LM41CIMT
Package
Marking
LM41
Package Transport
Number Media
MTC14C 94 units per
rail
TSSOP-14
CIMT
LM41CIMTX
LM41
MTC14C 2500 units in
tape and reel
CIMT
20070302
Top View
National Package Number MTC14C
Pin Description
Pin Number
Pin Name
Description
Typical Connection
1, 10, 13, 14
NC
No Connect
May be tied to V+, GND or left floating. Do
not tie active signals to pin 10.
System ground
2
3
GND
Ground
V+/+3.3V_SBY
Positive power supply pin as well
as a +3.3V voltage monitor
Connected system 3.3 V standby power and
to a 0.1 µF bypass capacitor in parallel with
100 pF. A bulk capacitance of approximately
10 µF needs to be in the near vicinity of the
LM41.
4
5
SWD
ADD
SensorPath Bus line; Open-drain
output
Super I/O, Pull-up resistor, 1.6k
Digital input - device number select Pull-up to 3.3 V or pull-down to GND resistor,
input for the serial bus device
number
10k; must never be left floating
6
7
8
+1.2V
+2.5V
D-
+1.2V voltage monitoring input with Processor core voltage to be monitored
scaling resistors
+2.5V voltage monitoring input with Power supply voltage to be monitored
scaling resistors
Thermal diode analog voltage
output and negative monitoring
input
Remote Thermal Diode cathode
(THERM_DC) - Can be connected to a CPU
or thermal diode, an MMBT3904 or a GPU
thermal diode. A 100 pF capacitor should be
connected between respective D- and D+ for
noise filtering.
9
D+
Thermal diode analog current
Remote Thermal Diode anode (THERM_DA) -
output and positive monitoring input Can be connected to a CPU or thermal diode,
an MMBT3904 or a GPU thermal diode. A
100 pF capacitor should be connected
between respective D- and D+ for noise
filtering.
11
12
+5V
+5V voltage monitoring input with
scaling resistors
Power supply voltage to be monitored
+12V
+12V voltage monitoring input with Power supply voltage to be monitored
scaling resistors
www.national.com
2
Block Diagram
20070303
3
www.national.com
Absolute Maximum Ratings
Soldering process must comply with National’s reflow
temperature profile specifications. Refer to
www.national.com/packaging/. (Note 6)
(Notes 2, 1)
Supply Voltage (V+)
−0.5 V to 6.0 V
Voltage at Any Digital Input or
Output Pin
Operating Ratings
−0.5 V to 6.0 V
−0.5 V to 16 V
−0.5 V to 6.67 V
−0.5 V to (V+ + 0.05 V)
−0.5 V to 6.0 V
1 mA
(Notes 1, 2)
Voltage on 12V Analog Input
Voltage on 5V Analog Input
Voltage on D+
Temperature Range for Electrical Characteristics
LM41CIMT (TMIN≤TA≤TMAX
)
0˚C ≤ TA ≤ +85˚C
0˚C ≤ TA ≤ +125˚C
Voltage on Other Analog Inputs
Current on D-
Operating Temperature Range
Remote Diode Temperature (TD)
Range
Input Current per Pin(Note 3)
Package Input Current (Note 3)
Package Power Dissipation
Output Sink Current
5 mA
-5˚C ≤ TD ≤ +140˚C
30 mA
Supply Voltage Range (V+)
Analog Input Voltage Rage:
+1.2V and +2.5V
+3.0 V to +3.6 V
(Note 4)
10 mA
−0.05V to
(V+ + 0.05V)
ESD Susceptibility (Note 5)
Human Body Model
+3.3V_SBY (V+)
+3.0V to +3.6V
−0.05V to +6.67V
−0.05V to +16V
2500 V
250 V
+5V
Machine Model
+12V
Storage Temperature
−65˚C to +150˚C
DC Electrical Characteristics
The following specifications apply for V+ = +3.0 VDC to +3.6 VDC, and all analog source impedance RS = 50 Ω unless other-
wise specified in the conditions. Boldface limits apply for LM41CIMT TA = TJ = TMIN=0˚C to TMAX=85˚C; all other limits
TA = +25˚C. TA is the ambient temperature of the LM41; TJ is the junction temperature of the LM41; TD is the junction tem-
perature of the remote thermal diode.
POWER SUPPLY CHARACTERISTICS
Typical
(Note 7)
Limits
(Note 8)
3.0
Units
(Limit)
V (min)
V (max)
Symbol
V+
Parameter
Power Supply Voltage
Conditions
3.3
3.6
SensorPath Bus Inactive
(Note 9)
I+Shutdown
Shutdown Power Supply Current
Average Power Supply Current
260
420
900
3.3
µA (max)
µA (max)
mA (max)
SensorPath Bus Inactive; all
sensors enabled;
I+Average
tCONV=182 ms; (Note 9)
SensorPath Bus Inactive
(Note 9)
I+Peak
Peak Power Supply Current
1.6
2.8
V (min)
V (max)
Power-On Reset Threshold Voltage
TEMPERATURE-TO-DIGITAL CONVERTER CHARACTERISTICS
Typical
(Note 7)
Limits
(Note 8)
Units
(Limits)
Parameter
Conditions
Temperature Accuracy Using the Remote Thermal TJ = 0˚C to
Diode, see (Note 12) for Thermal Diode Processor +85˚C
TD = +25˚C
1
2.5
˚C (max)
˚C (max)
˚C (max)
Type.
TJ = 0˚C to
+85˚C
TD = 0˚C to
+100˚C
3
TJ = 0˚C to
+85˚C
TD = +100˚C to
+125˚C
4
3
Temperature Accuracy Using the Local Diode
Remote Diode and Local Temperature Resolution
TJ = 0˚C to +85˚C (Note 10)
1
10
˚C (max)
Bits
˚C
V
0.5
0.7
D− Source Voltage
www.national.com
4
TEMPERATURE-TO-DIGITAL CONVERTER CHARACTERISTICS
Parameter Conditions
Diode Source Current
Typical
(Note 7)
188
Limits
(Note 8)
280
Units
(Limits)
µA (max)
µA
(VD+ − VD−) = +0.65 V; High Current
Low Current
11.75
Diode Source Current High Current to Low Current
Ratio
16
ANALOG TO DIGITAL CONVERTER CHARACTERISTICS
Symbol
Parameter
Conditions
Typical
(Note 7)
Limits
(Note 8)
2
Units
(Limit)
%FS
TUE
DNL
Total Unadjusted Error(Note 11)
(max)
Bits
Resolution
9
Differential Non-linearity
Power Supply Sensitivity
Input Resistance, all analog inputs (total resistance
of divider chain)
1
1
LSB
%/V
210
140
400
kΩ (min)
kΩ (max)
SWD and ADD DIGITAL INPUT CHARACTERISTICS
Typical
(Note 7)
Limits
(Note 8)
2.1
Units
(Limit)
V (min)
V (max)
V (max)
V (min)
V (min)
V (max)
mV
Symbol
Parameter
Conditions
VIH
SWD Logical High Input Voltage
V+ + 0.5
0.8
VIL
SWD Logical Low Input Voltage
-0.5
VIH
VIL
ADD Logical High Input Voltage
ADD Logical Low Input Voltage
Input Hysteresis
90% x V+
10% x V+
VHYST
IL
300
SWD and ADD Input Current
GND ≤ VIN ≤ V+
0.005
0.005
10
µA (max)
µA
SWD Input Current with V+ Open or GND ≤ VIN ≤ 3.6V,
Grounded
and V+ Open or
GND
CIN
Digital Input Capacitance
10
pF
SWD DIGITAL OUTPUT CHARACTERISTICS
Typical
(Note 7)
Limits
(Note 8)
0.4
Units
(Limit)
V (max)
V (max)
µA (max)
pF
Symbol
Parameter
Conditions
VOL
Open-drain Output Logic “Low”
Voltage
I
I
= 4mA
= 50µA
OL
OL
0.2
IOH
Open-drain Output Off Current
Digital Output Capacitance
0.005
10
10
COUT
AC Electrical Characteristics
The following specification apply for V+ = +3.0 VDC to +3.6 VDC, unless otherwise specified. Boldface limits apply for
TA = TJ = TMIN=0˚C to TMAX=85˚C; all other limits TA = TJ = 25˚C. The SensorPath Characteristics conform to the SensorPath
specification revision 0.98. Please refer to that speciation for further details.
Typical
Limits
Units
Symbol
HARDWARE MONITOR CHARACTERISTICS
tCONV Total Monitoring Cycle Time (Note 13)
Parameter
Conditions
(Note 7) (Note 8)
(Limits)
All Voltage and
Temperature readings
(Default)
182
163.8
200.2
ms (min)
ms (max)
5
www.national.com
AC Electrical Characteristics (Continued)
The following specification apply for V+ = +3.0 VDC to +3.6 VDC, unless otherwise specified. Boldface limits apply for
TA = TJ = TMIN=0˚C to TMAX=85˚C; all other limits TA = TJ = 25˚C. The SensorPath Characteristics conform to the SensorPath
specification revision 0.98. Please refer to that speciation for further details.
Typical
Limits
Units
Symbol
Parameter
Conditions
(Note 7) (Note 8)
(Limits)
SensorPath Bus CHARACTERISTICS
tf
tr
SWD fall time (Note 16)
Rpull-up=1.25 kΩ 30%,
CL=400 pF
300
1000
11
ns (max)
ns (max)
µs (min)
SWD rise time (Note 16)
Rpull-up=1.25 kΩ 30%,
CL=400 pF
tINACT
Minimum inactive time (bus at high level)
guaranteed by the slave before an attention
request
tMtr0
tMtr1
Master drive for Data Bit 0 write and for Data
Bit 0-1read
11.8
17.0
35.4
48.9
9.6
µs (min)
µs (max)
µs (min)
µs (max)
µs (max)
µs (min)
µs (max)
µs (min)
µs (max)
µs (min)
µs (max)
µs (min)
ms (max)
Master drive for Data Bit 1 write
tSFEdet
tSLout1
Time allowed for LM41 activity detection
LM41 drive for Data Bit 1 read by master
28.3
38.3
80
tMtrS
Master drive for Start Bit
109
165
228
354
500
tSLoutA
LM41 drive for Attention Request
tRST
Master or LM41 drive for Reset
tRST_MAX
Maximum drive of SWD by an LM41, after the
power supply is raised above 3V
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 2: All voltages are measured with respect to GND, unless otherwise noted.
<
>
V+), the current at that pin should be limited to 5 mA. Parasitic
Note 3: When the input voltage (V ) at any pin exceeds the power supplies (V
GND or V
IN
IN
IN
components and/or ESD protection circuitry are shown below for the LM41’s pins. The nominal breakdown voltage of the zener is 6.5 V. SNP stands for snap-back
device.
www.national.com
6
PIN
#
Pin
Name
Pin
Circuit
All Input Structure Circuits
1
2
NC
A
B
GND
V+/
3
B
3.3V SB
Circuit A
4
5
SWD
ADD
+1.2V
+2.5V
D-
A
A
C
C
D
E
E
Circuit B
6
7
8
9
D+
Circuit C
10
NC
Circuit D
11
12
13
14
+5V
+12V
NC
C
C
none
A
NC
Circuit E
Note 4: Thermal resistance junction-to-ambient in still air when attached to a printed circuit board with 1 oz. foil is 148 ˚C/W.
Note 5: Human body model, 100 pF discharged through a 1.5 kΩ resistor. Machine model, 200 pF discharged directly into each pin.
Note 6: Reflow temperature profiles are different for lead-free and non lead-free packages.
Note 7: “Typicals” are at T = 25˚C and represent most likely parametric norm. They are to be used as general reference values not for critical design calculations.
A
Note 8: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level).
Note 9: The supply current will not increase substantially with a SensorPath transaction.
Note 10: Local temperature accuracy does not include the effects of self-heating. The rise in temperature due to self-heating is the product of the internal power
dissipation of the LM41 and the thermal resistance. See (Note 4) for the thermal resistance to be used in the self-heating calculation.
Note 11: TUE , total unadjusted error, includes ADC gain, offset, linearity and reference errors. TUE is defined as the "actual Vin" to achieve a given code transition
minus the "theoretical Vin" for the same code. Therefore, a positive error indicates that the input voltage is greater than the theoretical input voltage for a given code.
If the theoretical input voltage was applied to an LM41 that has positive error, the LM41’s reading would be less than the theoretical.
Note 12: The accuracy of the LM41CIMT is guaranteed when using the thermal diode of an Intel 90 nm Pentium 4 processor or any thermal diode with a non-ideality
factor of 1.011 and series resistance of 3.33Ω. When using a MMBT3904 type transistor as a thermal diode the error band will be typically shifted by -4.5 ˚C.
Note 13: This specification is provided only to indicate how often temperature and voltage data are updated.
Note 14: The output fall time is measured from (V
) to (V
).
IH min
IL max
Note 15: The output rise time is measured from (V
) to (V
).
IL max
IH min
Note 16: The rise and fall times are not tested but guaranteed by design.
7
www.national.com
Timing Diagrams
20070304
FIGURE 1. Timing for Data Bits 0, 1 and Start Bit. See Section 1.2 "SensorPath BIT SIGNALING" for further details.
www.national.com
8
Timing Diagrams (Continued)
20070305
FIGURE 2. Timing for Attention Request and Reset. See Section 1.2 "SensorPath BIT SIGNALING" for further details.
9
www.national.com
Typical Performance Characteristics
Remote Diode Temperature Reading Sensitivity to Diode
Filter Capacitance
Thermal Diode Capacitor or PCB Leakage Current Effect
on Remote Diode Temperature Reading
20070321
20070322
1.0 Functional Description
The LM41 hardware monitor measures up to 2 temperature
zones and 5 power supply voltages. The LM41 uses a ∆Vbe
temperature sensing method. A differential voltage, repre-
senting temperature, is digitized using a Sigma-Delta analog
to digital converter. Internal scaling resistors allow direct
measurement of the +1.6V, +2.5V, +5V, +3.3V and +12V
power supply inputs. The digitized data can be retrieved over
a simple single-wire interface called SensorPath. Sensor-
Path has been defined by National Semiconductor and is
optimized for hardware monitoring. National offers a royalty-
free license in connection with its intellectual property rights
in the SensorPath bus.
20070307
FIGURE 3. SensorPath SWD simplified schematic
The LM41 has one address pin to allow up to two LM41s to
be connected to one SensorPath bus. The physical interface
of SensorPath’s SWD signal is identical to the familiar indus-
try standard SMBus SMBDAT signal. The digital information
is encoded in the pulse width of the signal being transmitted.
Every bit can be synchronized by the master simplifying the
implementation of the master when using a micro-controller.
For micro-controller’s with greater functionality an asynchro-
nous attention signal can be transmitted by the LM41 to
interrupt the micro-controller and notify it that temperature/
voltage data has been updated in the readout registers.
1.2 SensorPath BIT SIGNALING
Signals are transmitted over SensorPath using pulse-width
encoding. There are five types of "bit signals":
•
•
•
•
•
Data Bit 0
Data Bit 1
Start Bit
Attention Request
Reset
All the "bit signals" involve driving the bus to a low level. The
duration of the low level differentiates between the different
"bit-signals". Each "bit signal" has a fixed pulse width. Sen-
sorPath supports a Bus Reset Operation and Clock Training
sequence that allows the slave device to synchronize its
internal clock rate to the master. Since the LM41 meets the
15% timing requirements of SensorPath, the LM41 does
not require the Clock Training sequence and does not sup-
port this feature. This section defines the "bit signal" behav-
ior in all the modes. Please refer to the timing diagrams in
the Electrical Characteristics section (Figure 1 and Figure 2)
while going through this section. Note that the timing dia-
grams for the different types of "bit signals" are shown
together to better highlight the timing relationships between
them. However, the different types of "bit signals" appear on
SWD at different points in time. These timing diagrams show
the signals as driven by the master and the LM41 slave as
well as the signal as seen when probing SWD. Signal labels
that begin with the label Mout_ depict a drive by the master.
To optimize the LM41’s power consumption to the system
requirements, the LM41 has a shutdown mode and supports
multiple conversion rates.
1.1 SensorPath BUS SWD
SWD is the Single Wire Data line used for communication.
SensorPath uses 3.3V single-ended signaling, with a pull-up
resistor and open-drain low-side drive (see Figure 3). For
timing purposes SensorPath is designed for capacitive loads
(CL) of up to 400pF. Note that in many cases a 3.3V standby
rail of the PC will be used as a power supply for both the
sensor and the master. Logic high and low voltage levels for
SWD are TTL compatible. The master may provide an inter-
nal pull-up resistor. In this case the external resistor is not
needed. The minimum value of the pull-up resistor must take
into account the maximum allowable output load current of
4mA.
www.national.com
10
measuring the time SWD is active (low). If an Attention
Request or Reset condition is detected, the current "bit
signal" is not treated as a Start Bit. The master may attempt
to send the Start Bit at a later time.
1.0 Functional Description (Continued)
Signal labels that begin with the label Slv_ depict the drive by
the LM41. All other signals show what would be seen when
probing SWD for a particular function (e.g. "Master Wr 0" is
the Master transmitting a Data Bit with the value of 0).
1.2.4 Attention Request
The LM41 may initiate an Attention Request when the Sen-
sorPath bus is inactive.
1.2.1 Bus Inactive
The bus is inactive when the SWD signal is high for a period
of at least tINACT. The bus is inactive between each "bit
signal".
Note that a Data Bit, or Start Bit, from the master may start
simultaneously with an Attention Request from the LM41. In
addition, two LM41s may start an Attention Request simul-
taneously. Due to its length, the Attention Request has pri-
ority over any other "bit signal", except Reset. Conflict with
Data Bits and Start Bits are detected by all the devices, to
allow the bits to be ignored and re-issued by their originator.
1.2.2 Data Bit 0 and 1
All Data Bit signal transfers are started by the master. A Data
Bit 0 is indicated by a "short" pulse; a Data Bit 1 is indicated
by a longer pulse. The direction of the bit is relative to the
master, as follows:
The LM41 will either check to see that the bus is inactive
before starting an Attention Request, or start the Attention
Request within the tSFEdet time interval after SWD becomes
active. The LM41 will drive the signal low for tSLoutA time.
After this, both the master and the LM41 must monitor the
bus for a Reset Condition. If a Reset condition is detected,
the current "bit signal" is not treated as an Attention Request.
•
Data Write - a Data Bit transferred from the master to the
LM41.
•
Data Read - a Data Bit transferred from the LM41 to the
master.
A master must monitor the bus as inactive before starting a
Data Bit (Read or Write).
After Reset, an Attention Request can not be sent before the
master has sent 14 Data Bits on the bus. See Section 1.3.5
for further details on Attention Request generation.
A master initiates a data write by driving the bus active (low
level) for the period that matches the data value (tMtr0 or tMtr1
for a write of "0" or "1", respectively). The LM41 will detect
that the SWD becomes active within a period of tSFEdet, and
will start measuring the duration that the SWD is active in
order to detect the data value.
1.2.5 Bus Reset
The LM41 issues a Reset at power up. The master must also
generate a Bus Reset at power-up for at least the minimum
reset time, it must not rely on the LM41. SensorPath puts no
limitation on the maximum reset time of the master. Follow-
ing a Bus Reset, the LM41 may generate an Attention Re-
quest only after the master has sent 14 Data Bits on the bus.
See Section 1.3.5 for further details on Attention Request
generation.
A master initiates a data read by driving the bus for a period
of tMtr0. The LM41 will detect that the SWD becomes active
within a period of tSFEdet. For a data read of "0", the LM41
will not drive the SWD. For a data read of "1" the LM41 will
start within tSFEdet to drive the SWD low for a period of
tSLout1. Both master and LM41 must monitor the time at
which the bus becomes inactive to identify a data read of "0"
or "1".
1.3 SensorPath BUS TRANSACTIONS
SensorPath is designed to work with a single master and up
to seven slave devices. Each slave has a unique address.
The LM41 supports up to 2 device addresses that are se-
lected by the state of the address pin ADD. The Register Set
of the LM41 is defined in Section 2.0.
During each Data Bit, both the master and all the LM41s
must monitor the bus (the master for Attention Request and
Reset; the LM41s for Start Bit, Attention Request and Reset)
by measuring the time SWD is active (low). If a Start Bit,
Attention Requests or Reset "bit signal" is detected, the
current "bit signal" is not treated as a Data Bit.
1.3.1 Bus Reset Operation
Note that the bit rate of the protocol varies depending on the
data transferred. Thus, the LM41 has a value of "0" in
reserved or unused register bits for bus bandwidth efficiency.
A Bus Reset Operation is global on the bus and affects only
the communication interface of all the devices connected to
it. The Bus Reset operation does not affect either the con-
tents of the device registers, or device operation, to the
extent defined in LM41 Register Set, see Section 2.0.
1.2.3 Start Bit
A master must monitor the bus as inactive before beginning
a Start Bit.
The Bus Reset operation is performed by generating a Reset
signal on the bus. The master must apply Reset after power-
up, and before it starts operation. The Reset signal end will
be monitored by all the LM41s on the bus.
The master uses a Start Bit to indicate the beginning of a
transfer. LM41s will monitor for Start Bits all the time, to allow
synchronization of transactions with the master. If a Start Bit
occurs in the middle of a transaction, the LM41 being ad-
dressed will abort the current transaction. In this case the
transaction is not "completed" by the LM41 (see Section 1.3
"SensorPath Bus Transactions").
After the Reset Signal the SensorPath specification requires
that the master send a sequence of 8 Data Bits with a value
of "0", without a preceding Start Bit. This is required to
enable slaves that "train" their clocks to the bit timing. The
LM41 does not require nor does it support clock training.
During each Start Bit, both the master and all the LM41s
must monitor the bus for Attention Request and Reset, by
11
www.national.com
1.0 Functional Description (Continued)
20070308
FIGURE 4. Bus Reset Transaction
1.3.2 Read Transaction
•
Acknowledge (ACK) During a read transaction the ACK
bit is sent by the master indicating that the EP bit was
received and was found to be correct, when compared to
the data preceding it, and that no conflict was detected
on the bus (excluding Attention Request - see Section
1.3.5 "Attention Request Transaction"). A read transfer is
considered "complete" only when the ACK bit is received.
A transaction that was not positively acknowledged is not
considered "complete" by the LM41 and following are
performed:
During a read transaction, the master reads data from a
register at a specified address within a slave. A read trans-
action begins with a Start Bit and ends with an ACK bit, as
shown in Figure 5.
•
Device Number This is the address of the LM41 device
accessed. Address "000" is a broadcast address and can
be responded to by all the slave devices. The LM41
ignores the broadcast address during a read transaction.
•
Internal Address The address of a register within the
— The BER bit in the LM41 Device Status register is set
LM41 that is read.
— The LM41 generates an Attention Request before, or
together with the Start Bit of the next transaction
•
•
Read/Write (R/W) A "1" indicates a read transaction.
Data Bits During a read transaction the data bits are
driven by the LM41. Data is transferred serially with the
most significant bit first. This allows throughput optimiza-
tion based on the information that needs to be read.
A transaction that was not positively acknowledged is
also not considered "complete" by the master (i.e. inter-
nal operations related to the transaction are not per-
formed). The transaction may be repeated by the master,
after detecting the source of the Attention Request (the
LM41 that has a set BER bit in the Device Status regis-
ter). Note that the SensorPath protocol neither forces, nor
automates re-execution of the transaction by the master.
The LM41 supports 8-bit or 16-bit data fields, as de-
scribed in Section 2.0 "Register Set".
•
Even Parity (EP) This bit is based on all preceding bits
(device number, internal address, Read/Write and data
bits) and the parity bit itself. The parity -number of 1’s - of
all the preceding bits and the parity bit must be even - i.e.,
the result must be 0. During a read transaction, the EP bit
is sent by the LM41 to the master to allow the master to
check the received data before using it.
The values of the ACK bit are:
— 1: Data was received correctly
— 0: An error was detected (no-acknowledge).
20070309
FIGURE 5. Read Transaction, master reads data from LM41
1.3.3 Write Transaction
•
•
Internal Address This is the register address in the
LM41 that will be written.
In a write transaction, the master writes data to a register at
a specified address in the LM41. A write transaction begins
with a Start Bit and ends with an ACK Data Bit, as show in
Figure 6.
Read/Write (R/W) A "0" data bit directs a write transac-
tion.
•
Device Number This is the address of the slave device
accessed. Address "000" is a broadcast address and is
responded to by all the slave devices. The LM41 re-
sponds to broadcast messages to the Device Control
Register.
www.national.com
12
Request - see Section 1.3.5 "Attention Request Transac-
tion"). A write transfer is considered "completed" only
when the ACK bit is generated. A transaction that was not
positively acknowledged is not considered complete by
the LM41 (i.e. internal operation related to the transaction
are not performed) and the following are performed:
1.0 Functional Description (Continued)
•
Data Bits This is the data written to the LM41 register,
are driven by the master. Data is transferred serially with
the most significant bit first. The number of data bits may
vary from one address to another, based on the size of
the register in the LM41. This allows throughput optimi-
zation based on the information that needs to be written.
— The BER bit in the LM41 Device Status register is set;
— The LM41 generates an Attention Request before, or
together with the Start Bit of the next transaction
The LM41 supports 8-bit or 16-bit data fields, as de-
scribed in Section 2.0 "Register Set".
A transaction that was not positively acknowledged is
also not considered "complete" by the master (i.e. inter-
nal operations related to the transaction are not per-
formed). The transaction may be repeated by the master,
after detecting the source of the Attention Request (the
LM41 that has a set BER bit in the Device Status regis-
ter). Note that the SensorPath protocol neither forces, nor
automates re-execution of the transaction by the master.
•
•
Even Parity (EP) This data bit is based on all preceding
bits (Device Number, Internal Address, Read/Write and
Data bits) and the Even Parity bit itself. The parity (num-
ber of 1’s) of all the preceding bits and the parity bit must
be even - i.e. the result must be 0. During a write trans-
action, the EP bit is sent by the master to the LM41 to
allow the LM41 to check the received data before using it.
Acknowledge (ACK) During the write transaction the
ACK bit is sent by the LM41 indicating to the master that
the EP was received and was found correct, and that no
conflict was detected on the bus (excluding Attention
The values of the ACK bit are:
— 1: Data was received correctly;
— 0: An error was detected (no-acknowledge).
20070310
FIGURE 6. Write Transaction, master write data to LM41
1.3.4 Read and Write Transaction Exceptions
generating a Start Bit, the LM41 aborts the current transac-
tion (the LM41 does not "complete" the current transaction)
and begins the new transaction. The master is not notified by
the LM41 of the incomplete transaction.
This section describes master and LM41 handling of special
bus conditions, encountered during either Read or Write
transactions.
If an LM41 receives a Start Bit in the middle of a transaction,
it aborts the current transaction (the LM41 does not "com-
plete" the current transaction) and begins a new transaction.
Although not recommend for SensorPath normal operation,
this situation is legitimate, therefore it is not flagged as an
error by the LM41 and Attention Request is not generated in
response to it. The master generating the Start Bit, is re-
sponsible for handling the not "complete" transaction at a
"higher level".
1.3.5 Attention Request Transaction
Attention Request is generated by the LM41 when it needs
the attention of the master. The master and all LM41s must
monitor the Attention Request to allow bit re-sending in case
of simultaneous start with a Data Bit or Start Bit transfer.
Refer to the "Attention Request" section, Section 1.2.4 in the
"Bit Signaling" portion of the data sheet.
The LM41 will generate an Attention Request using the
following rules:
If LM41 receives more than the expected number of data bits
(defined by the size of the accessed register), it ignores the
unnecessary bits. In this case, if both master and LM41
identify correct EP and ACK bits they "complete" the trans-
action. However, in most cases, the additional data bits differ
from the correct EP and ACK bits. In this case, both the
master and the LM41 do not "complete" the transaction. In
addition, the LM41 performs the following:
1. A Function event that sets the Status Flag has occurred
and Attention Request is enabled and
2. The "physical" condition for an Attention Request is met
(i.e., the bus is inactive), and
3. At the first time 2 is met after 1 occurred, there has not
been an Attention request on the bus since a read of the
Device Status register, or since a Bus Reset.
•
•
the BER bit in the LM41 Device Status register is set
the LM41 generates an Attention Request
OR
1. A bus error event occurred, and
If the LM41 receives less than the expected number of data
bits (defined by the size of the accessed register), it waits
indefinitely for the missing bits to be sent by the master. If
then the master sends the missing bits, together with the
correct EP/ACK bits, both master and LM41 "complete" the
transaction. However, if the master starts a new transaction
2. the "physical" condition for an Attention Request is met
(i.e., the bus is inactive), and
3. At the first time 2. is met after 1 occurred, there has not
been a Bus Reset.
13
www.national.com
their Device Status register and must handle any pending
event in them before it may assume that there are no
more events to handle.
1.0 Functional Description (Continued)
All devices (master or slave) must monitor the bus for an
Attention Request signal. The following notes clarify the
intended system operation that uses the Attention Request
Indication.
Note: there is no indication of which slave has sent the
request. The requirement that multiple requests are not sent
allows the master to know within one scan of register reads
that there are no more pending events.
•
Masters are expected to use the attention request as a
trigger to read results from the LM41. This is done in a
sequence that covers all LM41s. This sequence is re-
ferred to as "master sensor read sequence".
1.3.6 Fixed Device Number Setting
The LM41 device number is defined by strapping of the ADD
pin. The LM41 will wake (after Device Reset) with the Device
Number field of the Device Number register set to the ad-
dress as designated in Section 2.3 "Device Number". It is the
responsibility of the system designer to avoid having two
devices with the same Device Number on the bus.
•
After an Attention Request is sent by an LM41 until after
the next read from the Device Status register the LM41
does not send Attention Requests for a function event
since it is guaranteed that the master will read the Status
register as part of the master sensor read sequence.
Note that the LM41 will send an attention for BER, re-
gardless of the Status register read, to help the master
with any error recovery operations and prevent dead-
locks.
Devices should be detected by the master by a read opera-
tion of the Device Number register. The read returns "000" if
there is no device at that address on the bus (the EP bit must
be ignored).
•
A master must record the Attention Request event. It
must then scan all slave devices in the system by reading
www.national.com
14
2.0 Register Set
2.1 REGISTER SET SUMMARY
P
O
R
Bit
15
MSb
Bit
0
LSb
Reg
Add
Register
Name
R/
W
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Val
Reserved
0
000 000 Device
00h Number
000 001 Manufacturer
R
R
R
*
Not Available
See Section 2.3
0
0
0
0
0
0
0
1
100Bh
24h
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
1
1
01h
ID
RevID
0
Device ID
1
000 010
02h
Device ID
0
0
0
0
0
0
1
0
0
FuncDescriptor 2
(Voltage-Only)
FuncDescriptor 1
(Temperature)
Reserved
000 011 Capabilities
03h Fixed
R
21h
0
0
0
0
0
0
0
0
0
0
Res
0
1
0
0
0
0
1
Reserved
000 100 Device
04h Status
000 101 Device
05h Control
R
0h
0h
Not Available
BER
ERF2ERF1
EnF2 EnF1
10-Bits
SF2 SF1
0
Res
0
0
Reserved
R/
W
Low Shut Re
Pwr down set
0
0
0
0
0
0
0
0
0
0
0
0
Sign
1
Int Rout
0.5˚C
Reserved
# of Remotes
001 000 Temperature
Sens Size
Resolution
R
0349h
08h
Capabilities
0
0
0
0
1
1
0
0
0
1
0
0
0
1
Processor/
Remote
Temperature
Data
Res
Res
EF
LSb
0.5
˚C
0
0
0
001 001
09h
MSb 128
Sign ˚C
1
S
Readout
Local
R
64˚C 32˚C 16˚C 8˚C 4˚C 2˚C
˚C
NUM
Res
0
Res Res
Temperature
Data
0
0
0
0
0
0
Readout
Reserved
001 010 Temperature R/
0h
EN1 EN0 ATE
0Ah
Control
W
0
0
0
0
0
0
0
0
0
0
0
0
0
0
001 011
-001 111 Reserved
0Bh-0Fh
R
Undefined
Rout
Size
0
Resolution
9-Bits
Reserved
0
# of Voltage Sensors
010 000 Voltage
R
R
0051h
10h
Capabilities
0
0
0
0
0
0
1
0
1
1
0
0
1
Voltage Readout
Reserved
Reserved
010 001 Voltage
11h Readout
SNUM
MSb
LSb
0
0
0
0
1
Low Rate Function
(Read Only)
Reserved
0
010 010 Voltage
R/
W
1Fh
2h
EN4 EN3 EN2 EN1 EN0 ATE
Undefined
12h
Control
0
0
0
1
1
1
010 011
-011 111 Reserved
13h-1Fh
R
Reserved
100 000 Conversion
R/
W
Not Available
CR1 CR0
20h
Rate
0
0
0
0
0
0
100 001
-111 111
21h-3Fh
Undefined
Registers
R
Undefined
15
www.national.com
2.0 Register Set (Continued)
* Depends on state of ADD pins see Section 2.3 "Device Number".
2.2 DEVICE RESET OPERATION
A Device Reset operation is performed in the following conditions:
•
•
At device power-up.
When the Reset bit in the Device Control register is set to 1 (see Section 2.8 "Device Control").
The Device Reset operation performs the following:
•
•
Aborts any device operation in progress and restarts device operation.
Sets all device registers to their "Reset" (default) value.
2.3 DEVICE NUMBER (Addr: 000 000; 00h)
This register is used to specify a unique address for each device on the bus.
P
R/
W
O
R
Bit 0
LSb
Reg Add
Register Name
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Val
Reserved
0
000 000
Device Number
R
7h or 1h
AS2
AS1
AS0
0
0
0
0
The value of [AS2:AS0] is determined by the setting of the ADD input pin:
TABLE 1. Device Number Assignment
ADD
[AS2:AS0]
001
0
1
111
The value of [AS2:AS0] will directly change and follow the value determined by ADD. Since this is a read only register the value
of the address cannot be changed by software.
2.4 MANUFACTURER ID (Addr: 000 001; 01h)
P
Bit
15
Bit
0
LSb
Reg
Add
Register
Name
R/
W
O
R
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
MSb
Val
Manufacturer
ID
000 001
R
100Bh
0
0
0
1
0
0
0
0
0
0
0
0
1
0
1
1
The manufacturer ID matches that assigned to National Semiconductor by the PCI SIG. This register may be used to identify the
manufacturer of the device in order to perform manufacturer specific operations.
www.national.com
16
2.0 Register Set (Continued)
2.5 DEVICE ID (Addr: 000 010; 02h)
P
O
R
Bit
15
MSb
Bit
0
LSb
Reg
Add
Register
Name
R/
W
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Val
RevID
0
DeviceID
1
000 010 Device ID
R
24h
0
0
0
0
0
0
0
0
0
0
0
1
0
0
The device ID is defined by the manufacturer of the device and is unique for each device produced by a manufacturer. Bits 15-11
identify the revision number of the die and will be incremented upon revision of the device.
Bit
Type
Description
10-0
RO DeviceID (Device ID Value) A fixed value that identifies the device.
15-11 RO RevID (Revision ID Value) A fixed value that identifies the device revision.
2.6 CAPABILITIES FIXED (Addr: 000 011; 03h)
P
O
R
Bit
15
MSb
Bit
0
LSb
Reg
Add
Register
Name
R/
W
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Val
Reserved
FuncDescriptor2
FuncDescriptor1
Capabilities
Fixed
000 011
R
21h
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
The value of this register defines the capabilities of the LM41. The LM41 supports two functions, that of Temperature
Measurement type (Function 1) and Voltage-Only Measurement type (Function 2). Please refer to the SensorPath specification
for further details on other FuncDescriptor values.
2.7 DEVICE STATUS (Addr: 000 100; 04h)
This register is set to the reset value by a Device Reset.
P
R/
W
O
R
Bit 0
LSb
Reg Add
Register Name
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Val
Res
0
Res
000 100
Device Status
R
0h
BER
ERF2
ERF1
SF2
SF1
0
0
Bit
Type
Description
0
RO SF1 (Status Function 1) This bit is set by a Function Event within Function 1. Event details are function
dependent and are described within the function. SF1 is cleared by Device Reset or by handling the event
within the Temperature Measurement Function (see Section 2.9 for further details).
0: Status flag for Function 1 is inactive (no event).
1: Status flag for Function 1 is active indicating that a Function Event has occurred.
RO SF2 (Status Function 2) Same as SF1 for Function 2, Voltage-Only Measurement Function. (see Section
2.10 for further details)
1
3-2
4
RO Reserved. Will always read "0".
RO ERF1 (Error Function 1) This bit is set in response to an error indication within Function 1. ERF1 is cleared
by Device Reset or by handling the error condition within the Temperature Measurement Function (see
Section 2.9 for further details).
0: No error occurred in Function 1.
1: Error occurred in Function 1.
5
6
RO ERF2 (Error Function 2) Same as ERF1 for Function 2, Voltage-Only Measurement Function. (see Section
2.10 for further details)
RO Reserved. Will always read "0".
17
www.national.com
2.0 Register Set (Continued)
Bit
Type
Description
7
RO BER (Bus Error) This bit is set when the device either generates, or receives an error indication in the ACK
bit of the transaction (i.e., no-acknowledge). BER is cleared by Device Reset or by reading the Device Status
register.
0: No transaction error occurred.
1: An ACK bit error (no-acknowledge) occurred during the last transaction.
2.8 DEVICE CONTROL (Addr: 000 101; 05h)
This register responds to a broadcast write command (Device Number 000). Write using broadcast address is ignored by bits
15-2. This register is set to the reset value by a Device Reset.
P
O
R
Bit
15
MSb
Bit
0
LSb
Reg
Add
Register
Name
R/
W
Bit Bit Bit Bit Bit
Bit Bit Bit Bit Bit Bit Bit Bit
Bit9
14
13
12
11
10
8
7
6
5
4
3
2
1
Val
Reserved
Device
Control
R/
W
Low Shut Re
Pwr down set
000 101
0h
EnF2 EnF1 Res
0
0
0
0
0
0
0
0
0
0
Bit
Type
Description
0
R/W Reset (Device Reset). When set to "1" this bit initiates a Device Reset operation ( See Section 2.2). This bit
self-clears after the Device Reset operation is completed.
0: Normal device operation. (default)
1: Device Reset
The LM41 does not require a Device Reset command after power.
R/W Shutdown (Shutdown Mode). When set to "1" this bit stops the operation of all functions and places the
device in the lowest power consumption mode.
1
2
0: Device in Active Mode. (default)
1: Device in Shutdown Mode.
R/W LowPwr (Low-Power Mode). When set to "1" this bit slows the operation of all functions and places the
device in a low power consumption mode. In Low-Power Mode, the conversion rate of the LM41 is effected
see Section 2.11 for further details.
0: Device in Active Mode. (default)
1: Device in Low-Power Mode.
3
4
RO Not supported. Will always read "0".
R/W EnF1 (Enable Function 1). When bit is set to "1" this bit Function 1 is enabled for operation. A function may
require setup before this bit is set. The function registers can be accessed even when the function is
disabled.
0: Function 1 is disabled. (default)
1: Function is enabled.
5
R/W EnF2 (Enable Function 2). Same as EnF1 for Function 2.
RO Not supported. Will always read "0".
15-6
2.9 TEMPERATURE MEASUREMENT FUNCTION (TYPE - 0001)
This section defines the register structure and operation of a Temperature Measurement function as it applies to the LM41. The
FuncDescriptor value of this function is ‘0001’.
2.9.1 Operation
The Temperature Measurement function as implemented in the LM41 supports 2 temperature zones, the LM41’s internal
temperature (LM41’s junction temperature) and the remote temperature of a thermal diode (stand alone transistors or integrated
in chips). The function measures multiple temperature points and reports the readout to the master. The measurement of all the
enabled temperature sensors is cyclic and continuous.
Sensor Scan The Control register of the function defines which temperature sensors are included in the scan. A sensor is
scanned only if it is enabled by the Sensor Enable bits (EN0 and EN1). The sensors are scanned in an ascending, round-robin
order, based on the sensor number. Disabled sensors are skipped and the next enabled sensor in ascending order is scanned.
www.national.com
18
2.0 Register Set (Continued)
The minimum scan rate is recommended to be 4Hz (i.e. the measurement data is updated at least once in 250 ms), see Section
2.11 for further details. In Low-Power Mode, the scan rate is four times lower than the scan rate in Active Mode. The scan rate
effects the bus bandwidth required to read the results. The sampling rate of the temperature measurements can also be controlled
via the Conversion Rate register, see Section 2.11 for further details.
Data Readout When a new result is stored in the Readout register a Function Event is generated. Reading the Readout
register clears the Status Function 1 flag (SF1). The result is available in the Readout register waiting for the master to read it
during the master sensor read sequence. If a new result is ready before the previous result has been read, the new result
overwrites the previous result and the Error Function 1 flag (ERF1) is set (indicating an overrun event). Reading the Readout
register clears also the Error Function 1 flag (ERF1). The Readout register contains the temperature data, and the sensor number.
Since the LM41 only supports three temperature zones the sensor number field will be zero to two. Other fields in the Readout
register as defined by the SensorPath specification are not supported.
Readout Resolution The resolution of the readout is defined in the Temperature Capabilities register. The resolution of the
LM41 is fixed and cannot be modified by software. The temperature readout type is common to all the sensors and is signed two’s
complement fixed point value. The readout type is specified in the Capabilities register of the function.
Sensor 0 in the Temperature Measurement function is reserved for local temperature measurement (i.e., the junction temperature
of the LM41).
Function Event
The Temperature Measurement function generates a Function Event whenever a conversion cycle is
completed and new data is stored in the Readout Register. When the new data is stored into the Readout register the SF1 bit in
the device Status register is set to "1" and remains set, until it is cleared by reading the Readout register. An Attention Request
is generated on the bus, only if it is enabled by the Attention Enable bit (ATE) in the Temperature Control register.
Setup Before Enabling No setup is required for the Temperature Measurement function before the function is enabled.
2.9.2 Temperature Capabilities (Addr: 001 000; 08h)
P
Bit
15
Bit
0
LSb
Reg
Add
Register
Name
R/
W
O
R
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
MSb
Val
Int Rout
0.5˚C
Reserved
# of Remotes
Sign
1
10-Bits
0
Temperature
Capabilities
Sens Size
Resolution
0 1
001 000
R
0349h
0
0
0
0
0
0
1
1
0
0
1
0
This register defines the format of the temperature data in the readout register. The LM41 only supports one format for all
temperatures as defined by the values of this register.
Bit
Type
Description
2-0
RO Resolution. This field defines the value of 1 LSb of the Temperature Readout field in the Readout Register.
The SensorPath specification defines many different weights for the temperature LSb. The LM41 supports a
resolution of 0.5 ˚C and thus a value of 001 for this field. For a full definition of this field, please refer to the
SensorPath specification.
5-3
RO Number of Bits. This field defines the total number of significant bits of the Temperature Readout field in the
Readout register. The total number of significant bits includes the number of bits representing the integer
part of the temperature data and the fractional part of it, as defined by the Resolution field. The LM41
supports 10-bits and thus a value of 001 for this field. For a full definition of this field please refer to the
SensorPath specification.
6
RO Sign (Signed Data). Defines the type of data in the Temperature Readout field of the Readout register.
0: Unsigned, positive fixed point value.
1: Signed, 2’s complement fixed point value. (value for the LM41)
7
8
RO RoutSize (Readout Register size). Defines the total size of the Readout register.
0: 16 bits. (value for the LM41)
RO IntSens (Internal Sensor Support). Indicates if the device supports internal temperature measurements, as
the LM41 does.
0: No internal temperature measurement
1: Internal temperature sensor implemented. (value for the LM41)
11-9
RO # of Remotes (Number of Remote Sensors). Specifies the number of remote Temperature Sensors
supported by the function.
1: The number of Remote Temperature Sensors. (value for the LM41)
15-12 RO Reserved. Will always read "0".
19
www.national.com
2.0 Register Set (Continued)
2.9.3 Temperature Data Readout (Addr: 001 001; 09h)
P
O
R
Bit
15
MSb
Bit
0
LSb
Reg
Add
Register
Name
R/
W
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Val
Local
Reserved
0
Reserved
Temperature
Data
0
0
0
0
Readout
Processor/
Remote
Temperature
Data
MSb 128
Sign ˚C
0.5
˚C
S
001 001
R
64˚C 32˚C 16˚C 8˚C 4˚C 2˚C 1˚C
NUM
Reserved
0
Res
EF
0
0
0
Readout
Bit
0
Type
Description
RO Reserved. Will always read "0".
RO Reserved for Local Temperature Data Readout. Will always read "0".
1
EF (Error Flag) for Remote Temperature Data Readout. This bit indicates that an error was detected
during the measurement of the current remote Temperature sensor such as a diode fault condition. When a
diode fault occurs the value of the temperature reading will be 200h or -256˚C.
0: No error detected.
1: Error detected.
2
RO SNUM (Sensor Number). This field indicates the number of the current Temperature Sensor, to which the
data in the Temperature Readout field belongs. Temperature Sensor 0 is always assigned to the local
sensor of the LM41.
0: Local temperature sensor (see Table Thermal Diode Input Mapping)
1: Remote sensor (see Table Thermal Diode Input Mapping)
5-3
RO Reserved. Will always read "0".
15-6
RO Temperature Readout. This field holds the result of the temperature measurement. The active size of this
field for the LM41 is 10-bits, left justified. See Table Temperature Data Format for examples.
Thermal Diode Input Mapping
Sensor Number
(SNUM)
Sensor Input
Local
Board Connection
0
1
none
Processor, D+/D-
CPU Thermal Diode, MMBT3904
Thermal Diode or GPU Thermal Diode
All LM41 temperature data has a common format. The LM41’s temperature data format is two’s complement and has 10-bits of
resolution with the LSb having a weight of 0.5 ˚C. The LM41 can resolve temperature between +255.5 ˚C and -256 ˚C, inclusive.
It can measure local temperatures between +85 ˚C and 0 ˚C and remote temperatures between +125 ˚C and 0 ˚C with an
accuracy of 3.0 ˚C.
Temperature Data Format
Temperature
+140 ˚C
+100 ˚C
+1 ˚C
Binary
Hex
118h
0C8h
002h
000h
3FFh
3FEh
3B0h
01 0001 1000
00 1100 1000
00 0000 0010
00 0000 0000
11 1111 1111
11 1111 1110
11 1011 0000
0 ˚C
- 0.5 ˚C
-1 ˚C
- 40 ˚C
www.national.com
20
2.0 Register Set (Continued)
Temperature Data Format (Continued)
Temperature
-255.5 ˚C
-256 ˚C
Binary
Hex
201h
200h
10 0000 0001
10 0000 0000
2.9.4 Temperature Control (Addr: 001 010; 0Ah)
This register is set to the reset value by a Device Reset.
P
O
R
Bit
15
MSb
Bit
0
LSb
Reg
Add
Register
Name
R/
W
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Val
Reserved
0
Temperature R/
001 010
0h
EN1 EN0 ATE
Control
W
0
0
0
0
0
0
0
0
0
0
0
Bit
Type
Description
0
R/W ATE (Attention Enable). When set, this bit enables an Attention Request signal to be generated by the
LM41, if the EN0, EN1 or EN2 bits of this register are set.
0: Attention Request disabled (from enabled Temperature Sensor- default)
1: Attention Request enabled (from enabled Temperature Sensor)
R/W EN0 (Enable Sensor 0). When this bit is set, the Local Temperature Sensor is enabled for temperature
measurements.
1
2
0: Temperature Sensor disabled (default)
1: Temperature Sensor enabled
R/W EN1 (Enable Sensor). When this bit is set, the Remote Thermal Diode Temperature Sensor is enabled for
temperature measurements.
0: Temperature Sensor disabled (default)
1: Temperature Sensor enabled
15-3
RO Reserved. Will always read "0".
2.10 VOLTAGE-ONLY MEASUREMENT FUNCTION (TYPE 0010)
This section defines the register structure and operation of the Voltage-Only Measurement Function. The FuncDescriptor value
of this function is ‘0010’.
2.10.1 Operation
The Voltage-Only measurement function is capable of measuring the voltage of voltage measurement points ("sensors"). These
may be general or dedicated inputs (e.g., for backup battery measurement or the supply voltage to the device). The measurement
of all the enabled voltage sensors is cyclic and continuous.
Sensor Scan The control register of the function defines which voltage sensors (inputs) are included in the scan. A sensor is
scanned only if it is enable by the Sensor Enable bit (EN0, EN1, EN2, EN3 and EN4). The sensors are scanned in an ascending,
round-robin order, based on the sensor number. Disable sensors are skipped and the next enabled sensor in ascending order is
scanned.
The minimum scan rate is recommended to be 4Hz (i.e., the measurement data is updated at least once in 250 ms), see Section
2.11 for further details. In Low-Power Mode, the scan rate is four times lower than the scan rate in Active Mode. The scan rate
effects the bus bandwidth required to read the results. The sampling rate of the voltage measurements can also be controlled via
the Conversion Rate register, see Section 2.11 for further details.
Data Readout When a new result is stored in the Readout register a Function Event is generated. Reading the Readout register
clears the Status Function 2 flag (SF2) for the Voltage-Only Measurement Function in the Device Status register. The result is
available in the Readout register waiting for the master to read it during the master sensor read sequence. The device should
delay or buffer additional conversions to allow the master time to read the result (see Sensor Scan Rate Section 2.11). If a new
result is ready before the previous result has been read, the new results overwrites the previous result and the Error Function 2
flag (ERF2) for the Voltage-Only function in the Device Status register is set (indicating an overrun event). Reading the
Voltage-Only Measurement Readout register clears also the ERF2 flag.
Readout Resolution The resolution of the readout register is defined in the Voltage Capabilities register. The resolution of the
LM41 is fixed and cannot be modified by software. The voltage readout format is common to all voltage sensors and is 9-bits
unsigned. For over or under input voltage conditions the data is guaranteed to saturate at all "1"s or "0"s so long as Operating
Ratings of the LM41 are adhered to.
21
www.national.com
2.0 Register Set (Continued)
Function Event The Voltage-Only Measurement function generates a Function Event to the master whenever a conversion
cycle is completed and new data is stored in the Readout register. When the new data is stored into the Readout register the SF2
bit in the Device Status register is set to 1 and remains set, until it is cleared by reading the Readout register. An Attention Request
is generated on the bus, only if it is enabled by the Attention Enable bit (ATE) in the Control register.
Setup Before Enabling No setup is required for the Voltage-Only Measurement function before it is enabled.
2.10.2 Voltage Capabilities (Addr: 010 000; 10h)
P
O
R
Bit
15
MSb
Bit
0
LSb
Reg
Add
Register
Name
R/
W
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Val
Rout
Size
0
Reserved
0
# of Voltage Sensors
9-bit Resolution
Voltage
010 000
R
0051h
Capabilities
0
0
0
0
0
0
0
0
1
0
1
0
0
1
This register defines the format of the voltage data in the voltage readout register. The LM41 only supports one format for all
voltage measurements as defined by the values of this register.
Bit
Type
Description
2-0
RO Resolution. This field defines the total number of significant bits in the Voltage Readout field in the Readout
register for this function. The voltage data is always aligned to the left in the Voltage Readout filed and is
extended with zeros.
001: 9-bit (value for the LM41 for other field values see the SensorPath specification)
RO RoutSize (Readout Register size). Defines the total size of the Readout register.
0: 16 bits. (value for the LM41 for other field values see the SensorPath specification)
RO # of Voltage Sensors (Number of Voltage Sensors). Specifies the number of Voltage Sensors supported
by this function.
3
8-4
5: The number of Voltage Sensors. (value for the LM41 for other field values see the SensorPath
specification)
15-9
RO Reserved. Will always read "0".
2.10.3 Voltage Readout (Addr: 010 001; 11h)
P
O
R
Bit
15
MSb
Bit
0
LSb
Reg
Add
Register
Name
R/
W
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Val
Voltage Readout
Reserved
Reserved
Voltage
010 001
R
SNUM
Readout
MSb
LSb
0
0
0
0
Bit
0-1
4-2
Type
Description
RO Reserved. Will always read "0".
RO SNUM (Sensor Number). This field indicates the number of the current Voltage Sensor, to which the data in
the Voltage Readout field belongs. See Table Analog Input Voltage Mapping for assignments.
RO Reserved. Will always read "0".
6-5
15-7
RO Voltage Readout. This field holds the result of the voltage measurement. The active size of this field for the
LM41 is 9-bits, left justified. See Table Analog Input Voltage Mapping for voltage mapping details.
www.national.com
22
2.0 Register Set (Continued)
Analog Input Voltage Mapping
Maximum
Input Voltage Input Voltage Register
for Nominal Range (V for Reading at
Register
Sensor
Number
(SNUM)
0
Reading
(code 384 or Max VIN for
Voltage Input 180h)
code 510.5 to Maximum
Reading at
Minimum
Input Voltage Voltage
Voltage
Range
1FFh
Minimum
pin)
Resolution
+2.5V
2.5V
1.2V
3.3V
5V
3.32V to 6V
-0.5V to
3.26mV
-0.5V to
2.63mV
3.0V
00h
00h
15Dh
00h
00h
6.51mV
1
2
3
4
+1.2V
1.6V to 6V
4.39V to 6V
6.65V
1FFh
1FFh
1FFh
5.86mV
8.59mV
13.02mV
31.25mV
+3.3V_SBY
(V+)
+5V
-0.5V to
6.51mV
-0.5V to
15.63mV
+12V
12V
15.95V to 16V 1FFh
2.10.4 Voltage Control (Addr: 010 010; 12h)
This register is set to the reset value by a Device Reset.
P
O
R
Bit
15
MSb
Bit
0
LSb
Reg
Add
Register
Name
R/
W
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Val
Low Rate Function
(Read Only)
Reserved
0
Voltage
Control
R/
W
010 010
1Fh
EN4 EN3 EN2 EN1 EN0 ATE
0
0
0
0
1
1
1
1
1
Bit
4-0
5
Type
Description
RO Low Rate Function This function is not supported by the LM41 and therefore this field is read only.
R/W ATE (Attention Enable). When set, this bit enables an Attention Request signal to be generated by the
LM41, if one or more EN0-EN4 bits of this register are set.
0: Attention Request disabled (from enabled Temperature Sensor- default)
1: Attention Request enabled
6
R/W EN0 (Enable Sensor 0). When this bit is set, the Voltage Sensor 0 is enabled for voltage measurements.
0: Voltage Sensor disabled (default)
1: Voltage Sensor enabled
10-7 R/W EN1-EN4 (Enable Sensor 1-4). Same as EN0 for Voltage sensors 1-4.
0: Voltage Sensor disabled (default)
1: Voltage Sensor enabled
15-11 RO Reserved. Will always read "0".
2.11 CONVERSION RATE (Addr: 100 000; 20h)
P
R/
W
O
R
Bit 0
LSb
Reg Add
Register Name
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Val
Reserved
R/
W
100 000
Conversion Rate
2h
CR1
CR0
0
0
0
0
0
0
23
www.national.com
2.0 Register Set (Continued)
Bit
Type
Description
1-0
RO CR0 and CR1 (Conversion Rate bits 0 and 1) These bits control the conversion rate of the LM41 for
more details see Table Conversion Rate Control and desciption below.
RO Reserved. Will always read "0".
7-2
Conversion Rate Control
LowPwr
[CR1:CR0]
Typical Conversion Rate (ms)
0
1
0
1
0
1
0
1
00
00
01
01
10
10
11
11
Fastest*: continuous
91
91
364
182 (default)
728
364
1456
*Fastest: 7.5ms(remote) + 7.5msec (local) + 5x1.42msec (voltage) = 22.1 ms total
The sensor conversion rate is controlled by this register as well as the Low Power Bit of Device Control Register. This register is
not defined by the SensorPath specification. Therefore, when using a Super I/O host on a motherboard this register must be
modified during BIOS run time. The conversion rate is dependent on system physical requirements and limitations. The thermal
response time of the MSOP package is one such requirement. Most systems will function properly with the default settings. The
master scan rate is related to the conversion rate of the LM41. If attentions are enabled the conversion rate and scan rate will be
equal.
3.0 Application Hints
The LM41 can be applied easily in the same way as other
integrated-circuit temperature sensors, and its remote diode
sensing capability allows it to be used in new ways as well.
It can be soldered to a printed circuit board, and because the
path of best thermal conductivity is between the die and the
pins, its temperature will effectively be that of the printed
circuit board lands and traces soldered to the LM41’s pins.
This presumes that the ambient air temperature is almost the
same as the surface temperature of the printed circuit board;
if the air temperature is much higher or lower than the
surface temperature, the actual temperature of the of the
LM41 die will be at an intermediate temperature between the
surface and air temperatures. Again, the primary thermal
conduction path is through the leads, so the circuit board
temperature will contribute to the die temperature much
20070315
more strongly than will the air temperature.
To measure temperature external to the LM41’s die, use a
remote diode. This diode can be located on the die of a
target IC, allowing measurement of the IC’s temperature,
FIGURE 7. 90 nm Pentium 4 Temperature vs LM41
Temperature Reading
independent of the LM41’s temperature. The LM41 has been
Most silicon diodes do not lend themselves well to this
optimized to measure the remote diode of a 90 nm Pentium
application. It is recommended that a 2N3904 transistor
4 processor as shown in Figure 7. A discrete diode can also
base emitter junction be used with the collector tied to the
base.
be used to sense the temperature of external objects or
ambient air. Remember that a discrete diode’s temperature
A diode connected 2N3904 approximates the junction avail-
will be affected, and often dominated, by the temperature of
able on a Pentium microprocessor for temperature measure-
its leads.
ment. Therefore, the LM41 can sense the temperature of this
diode effectively. Although, an offset will be observed. The
temperature reading will be offset by approximately −4.5˚C,
therefore a correction factor of +4.5˚C should be added to all
temperature readings when using a 2N3904 transistor.
www.national.com
24
3.0 Application Hints (Continued)
3.1 DIODE NON-IDEALITY
Processor Family
η, non-ideality
Series
R
min
typ
max
3.1.1 Diode Non-Ideality Factor Effect on Accuracy
Pentium II
1
1
1.0065 1.0173
1.0065 1.0125
When a transistor is connected as a diode, the following
relationship holds for variables VBE, T and If:
Pentium III CPUID 67h
Pentium III CPUID
1.0057 1.008 1.0125
68h/PGA370Socket/Celeron
Pentium 4, 423 pin
Pentium 4, 478 pin
Pentium 4 on 0.13
micron process,
2-3.06GHz
0.9933 1.0045 1.0368
0.9933 1.0045 1.0368
1.0011 1.0021 1.0030 3.64 Ω
where:
Pentium 4 on 90 nm
process
1.011
3.33 Ω
•
•
•
•
q = 1.6x10−19 Coulombs (the electron charge),
T = Absolute Temperature in Kelvin
k = 1.38x10−23joules/K (Boltzmann’s constant),
Pentium M Processor 1.00151 1.00220 1.00289 3.06 Ω
(Centrino)
MMBT3904
1.003
η is the non-ideality factor of the process the diode is
manufactured on,
AMD Athlon MP model 1.002 1.008 1.016
6
•
•
•
IS = Saturation Current and is process dependent,
If= Forward Current through the base emitter junction
VBE = Base Emitter Voltage drop
3.2 PCB LAYOUT for MINIMIZING NOISE
In the active region, the -1 term is negligible and may be
eliminated, yielding the following equation
In the above equation, η and IS are dependant upon the
process that was used in the fabrication of the particular
diode. By forcing two currents with a very controlled ration
(N) and measuring the resulting voltage difference, it is
possible to eliminate the IS term. Solving for the forward
voltage difference yields the relationship:
20070317
FIGURE 8. Ideal Diode Trace Layout
In a noisy environment, such as a processor mother board,
layout considerations are very critical. Noise induced on
traces running between the remote temperature diode sen-
sor and the LM41 can cause temperature conversion errors.
Keep in mind that the signal level the LM41 is trying to
measure is in microvolts. The following guidelines should be
followed:
The non-ideality factor, η, is the only other parameter not
accounted for and depends on the diode that is used for
measurement. Since ∆VBE is proportional to both η and T,
the variations in η cannot be distinguished from variations in
temperature. Since the non-ideality factor is not controlled by
the temperature sensor, it will directly add to the inaccuracy
of the sensor. For the Pentium III Intel specifies a 1%
variation in η from part to part. As an example, assume a
temperature sensor has an accuracy specification of 3˚C at
room temperature of 25 ˚C and the process used to manu-
facture the diode has a non-ideality variation of 1%. The
resulting accuracy of the temperature sensor at room tem-
perature will be:
1. Place the 100 pF and 0.1 µF power supply bypass
capacitors as close as possible to the LM41’s power pin.
Place the recommended thermal diode 100 pF capacitor
as close as possible to the LM41’s D+ and D− pins.
Make sure the traces to the thermal diode 100 pF ca-
pacitor are matched.
2. The recommended 100 pF diode capacitor actually has
a range of 0 pF to 3.3 nF (see curve in Typical Perfor-
mance Characteristics for effect on accuracy). The av-
erage temperature accuracy will not degrade. Increasing
the capacitance will lower the corner frequency where
differential noise error affects the temperature reading
thus producing a reading that is more stable. Con-
versely, lowering the capacitance will increase the cor-
ner frequency where differential noise error affects the
temperature reading thus producing a reading that is
less stable.
TACC
=
3˚C + ( 1% of 298 ˚K) = 6 ˚C
The additional inaccuracy in the temperature measurement
caused by η, can be eliminated if each temperature sensor is
calibrated with the remote diode that it will be paired with.
The following table shows the variations in non-ideality for a
variety of processors.
25
www.national.com
8. The ideal place to connect the LM41’s GND pin is as
close as possible to the Processors GND associated
with the sense diode.
3.0 Application Hints (Continued)
3. Ideally, the LM41 should be placed within 10cm of the
Processor diode pins with the traces being as straight,
short and identical as possible. Trace resistance of 0.7Ω
can cause as much as 1˚C of error. This error can be
compensated for by adding or subtracting an offset to
the remote temperature reading(s).
9. Leakage current between D+ and GND should be kept
to a minimum. Seventeen nano-amperes of leakage can
cause as much as 0.2˚C of error in the diode tempera-
ture reading (see curve in Section Typical Performance
Characteristics). Keeping the printed circuit board as
clean as possible will minimize leakage current.
4. Diode traces should be surrounded by a GND guard ring
to either side, above and below if possible. This GND
guard should not be between the D+ and D− lines. In the
event that noise does couple to the diode lines it would
be ideal if it is coupled common mode. That is equally to
the D+ and D− lines.
The SensorPath Bus is less sensitive to noise than its pre-
decessor the SMBus due to the inherent filtering present in
the pulse-width encoding of the data. Care still needs to be
taken such that induced noise is analyzed and minimized.
SensorPath Bus corrupt data is the most common symptom
for noise coupled in SWD. A no-ACK is the symptom for
noise coupled into the Device Number Select pin (ADD). An
RC lowpass filter as well as a debouncing circuit are in-
cluded in the LM41 that filter noise spikes less than 2.5 µsec
in duration on the SWD signal.
5. Avoid routing diode traces in close proximity to power
supply switching or filtering inductors.
6. Avoid running diode traces close to or parallel to high
speed digital and bus lines. Diode traces should be kept
at least 2cm apart from the high speed digital traces.
7. If it is necessary to cross high speed digital traces, the
diode traces and the high speed digital traces should
cross at a 90 degree angle.
www.national.com
26
Physical Dimensions inches (millimeters)
unless otherwise noted
14-Lead Molded Thin Shrink Small Outline Package (TSSOP,
JEDEC Registration Number MO-153 Variation AB Ref Note 6 dated 7/93,
Order Number LM41CIMT, or LM41CIMTX,
NS Package Number MTC14C
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL
COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical implant
into the body, or (b) support or sustain life, and
whose failure to perform when properly used in
accordance with instructions for use provided in the
labeling, can be reasonably expected to result in a
significant injury to the user.
2. A critical component is any component of a life
support device or system whose failure to perform
can be reasonably expected to cause the failure of
the life support device or system, or to affect its
safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor certifies that the products and packing materials meet the provisions of the Customer Products
Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification
(CSP-9-111S2) and contain no ‘‘Banned Substances’’ as defined in CSP-9-111S2.
National Semiconductor
Americas Customer
Support Center
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
National Semiconductor
Asia Pacific Customer
Support Center
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: new.feedback@nsc.com
Tel: 1-800-272-9959
Email: europe.support@nsc.com
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
Email: ap.support@nsc.com
Email: jpn.feedback@nsc.com
Tel: 81-3-5639-7560
www.national.com
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.
相关型号:
LM422-100.00M
LVDS Output Clock Oscillator, 100MHz Nom, ROHS COMPLIANT, HERMETIC SEALED, CERAMIC PACKAGE-6
CONNOR-WINFIE
LM422-670.00M
LVDS Output Clock Oscillator, 670MHz Nom, ROHS COMPLIANT, HERMETIC SEALED, CERAMIC PACKAGE-6
CONNOR-WINFIE
LM423-670.00M
LVDS Output Clock Oscillator, 670MHz Nom, ROHS COMPLIANT, HERMETIC SEALED, CERAMIC PACKAGE-6
CONNOR-WINFIE
©2020 ICPDF网 联系我们和版权申明