NAND04G-B2D, NAND08G-BxC
4 Gbit, 8 Gbit, 2112 byte/1056 word page
multiplane architecture, 1.8 V or 3 V, NAND Flash memories
Preliminary Data
Features
■ High density NAND Flash Memory
– Up to 8 Gbit memory array
– Cost-effective solution for mass storage
applications
■ NAND interface
TSOP48 12 x 20 mm (N)
– x8 or 16x bus width
– Multiplexed address/data
LGA
■ Supply voltage: 1.8 V or 3.0 V device
■ Page size
LGA52 12 x 17 mm (ZL)
– x8 device: (2048 + 64 spare) bytes
– x16 device: (1024 + 32 spare) words
r
■ Data protection:
■ Block size
– Hardware program/erase disabled during
power transitions
– x8 device: (128K + 4 K spare) bytes
– x16 device: (64K + 2 K spare) words
– Non-volatile protection option
■ ONFI 1.0 compliant command set
■ Data integrity
■ Multiplane architecture
– Array split into two independent planes
– Program/erase operations can be
– 100 000 program/erase cycles (with ECC
(error correction code))
performed on both planes at the same time
■ Page read/program
– 10 years data retention
– Random access: 25 µs (max)
– Sequential access: 25 ns (min)
– Page program time: 200 µs (typ)
®
■ ECOPACK packages
Table 1.
Device Summary
Part number
– Multiplane page program time (2 pages):
200 µs (typ)
Reference
NAND04GR3B2D
NAND04GW3B2D
NAND04GR4B2D(1)
NAND04GW4B2D(1)
NAND08GR3B2C,
NAND08GW3B2C
NAND08GR4B2C(1)
NAND08GW4B2C(1)
NAND08GR3B4C
NAND08GW3B4C
■ Copy back program with automatic error
detection code (EDC)
NAND04G-B2D
NAND08G-BxC
■ Cache read mode
■ Fast block erase
– Block erase time: 1.5 ms (typ)
– Multiblock erase time (2 blocks):
1.5 ms (typ)
■ Status Register
■ Electronic signature
■ Chip Enable ‘don’t care’
■ Serial number option
1. x16 organization only available for MCP products.
December 2007
Rev 3
1/69
This is preliminary information on a new product now in development or undergoing evaluation. Details are subject to
change without notice.
www.numonyx.com
1
Contents
NAND04G-B2D, NAND08G-BxC
Contents
1
2
3
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Memory array organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
3.11
Inputs/outputs (I/O0-I/O7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Inputs/Outputs (I/O8-I/O15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Address Latch Enable (AL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Command Latch Enable (CL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Chip Enable (E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Read Enable (R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Write Enable (W) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Write Protect (WP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Ready/Busy (RB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
V
DD supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SS ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
V
4
Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.1
4.2
4.3
4.4
4.5
4.6
Command input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Address input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Data output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Write protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5
6
Command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Device operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.1
Read memory array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.1.1
6.1.2
Random read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Page read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.2
Cache read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2/69
NAND04G-B2D, NAND08G-BxC
Contents
6.3
Page program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.3.1
6.3.2
Sequential input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Random data input in page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.4
6.5
6.6
6.7
6.8
6.9
Multiplane page program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Copy back program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Multiplane copy back program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Block erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Multiplane block erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Error detection code (EDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.10 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
6.11 Read Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.11.1 Write protection bit (SR7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.11.2 P/E/R Controller and cache ready/busy bit (SR6) . . . . . . . . . . . . . . . . . 34
6.11.3 P/E/R Controller bit (SR5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.11.4 Error bit (SR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.11.5 SR4, SR3, SR2 and SR1 are reserved . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.12 Read status enhanced . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.13 Read EDC Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.14 Read electronic signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
6.15 Read ONFI signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6.16 Read parameter page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
7
8
9
Concurrent operations and extended read status . . . . . . . . . . . . . . . . 43
Data protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Software algorithms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
9.1
9.2
9.3
9.4
9.5
Bad block management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
NAND Flash memory failure modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Garbage collection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Wear-leveling algorithm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Error correction code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
10
Program and erase times and endurance cycles . . . . . . . . . . . . . . . . . 48
3/69
Contents
11
NAND04G-B2D, NAND08G-BxC
Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
12
DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
12.1 Ready/Busy signal electrical characteristics . . . . . . . . . . . . . . . . . . . . . . 63
12.2 Data protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
13
14
15
Package mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
4/69
NAND04G-B2D, NAND08G-BxC
List of tables
List of tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Device Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Product description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Valid Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Address insertion (x8 devices) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Address insertion (x16 devices) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Address definition (x8 devices). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Address definition (x16 devices). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Copy back program addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Address definition for EDC units (x8 devices) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Address definition for EDC units (x16 devices) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Status Register bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
EDC Status Register bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Electronic signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Electronic signature byte 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Electronic signature byte 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Electronic signature byte 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Read ONFI signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Parameter page data structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Extended Read Status Register commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Block failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Program erase times and program erase endurance cycles . . . . . . . . . . . . . . . . . . . . . . . 48
Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Operating and AC measurement conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
DC characteristics (1.8 V devices) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
DC characteristics (3 V devices). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
AC characteristics for command, address, data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
AC characteristics for operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
TSOP48 - 48 lead plastic thin small outline, 12 x 20 mm, package mechanical data. . . . . 65
LGA52 12 x 17 mm, 1 mm pitch, package mechanical data . . . . . . . . . . . . . . . . . . . . . . . 66
Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Table 9.
Table 10.
Table 11.
Table 12.
Table 13.
Table 14.
Table 15.
Table 16.
Table 17.
Table 18.
Table 19.
Table 20.
Table 21.
Table 22.
Table 23.
Table 24.
Table 25.
Table 26.
Table 27.
Table 28.
Table 29.
Table 30.
Table 31.
Table 32.
Table 33.
Table 34.
Table 35.
5/69
List of figures
NAND04G-B2D, NAND08G-BxC
List of figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.
Logic block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
TSOP48 connections for NAND04G-B2D and NAND08G-BxC . . . . . . . . . . . . . . . . . . . . . 11
LGA52 connections for NAND04G-B2D and NAND08G-B2C devices. . . . . . . . . . . . . . . . 12
LGA52 connections for the NAND08G-B4C devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Memory array organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Read operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Random data output during sequential data output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Cache read (sequential) operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 10. Cache read (random) operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 11. Page program operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 12. Random data input during sequential data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 13. Multiplane page program waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 14. Copy back program (without readout of data) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 15. Copy back program (with readout of data) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 16. Page copy back program with random data input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 17. Multiplane copy back program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 18. Block erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 19. Multiplane block erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 20. Page organization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 21. Bad block management flowchart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 22. Garbage collection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 23. Error detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Figure 24. Equivalent testing circuit for AC characteristics measurement. . . . . . . . . . . . . . . . . . . . . . 51
Figure 25. Command latch AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 26. Address latch AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Figure 27. Data input latch AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Figure 28. Sequential data output after read AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Figure 29. Sequential data output after read AC waveforms (EDO mode) . . . . . . . . . . . . . . . . . . . . . 56
Figure 30. Read Status Register or read EDC Status Register AC waveform. . . . . . . . . . . . . . . . . . . 57
Figure 31. Read status enhanced waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 32. Read Electronic Signature AC waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 33. Read ONFI signature waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 34. Page read operation AC waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Figure 35. Page program AC waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 36. Block erase AC waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 37. Reset AC waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 38. Program/erase enable waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 39. Program/erase disable waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 40. Read parameter page waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 41. Ready/Busy AC waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 42. Ready/Busy load circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 43. Resistor value versus waveform timings for Ready/Busy signal. . . . . . . . . . . . . . . . . . . . . 64
Figure 44. Data protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 45. TSOP48 - 48 lead plastic thin small outline, 12 x 20 mm, package outline . . . . . . . . . . . . 65
Figure 46. LGA52 12 x 17 mm, 1 mm pitch, package outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
6/69
NAND04G-B2D, NAND08G-BxC
Description
1
Description
The NAND04G-B2D and NAND08G-BxC are part of the NAND Flash 2112 byte/1056 word
page family of non-volatile Flash memories. They use NAND cell technology have a density
of 4 Gbits and 8 Gbits, respectively.
The NAND04G-B2D memory array is split into 2 planes of 2048 blocks each. This
multiplane architecture makes it possible to program 2 pages at a time (one in each plane),
or to erase 2 blocks at a time (one in each plane). This feature reduces the average program
and erase times by 50%.
The NAND08G-BxC is a stacked device that combines two NAND04G-B2D dice, both of
which feature a multiplane architecture.
In the NAND08G-B2C devices, only one of the memory components can be enabled at a
time, therefore, operations can only be performed on one of the memory components at any
one time.
In the NAND08G-B4C devices, each NAND04G-B2D die can be accessed independently
using two sets of signals.
The devices operate from a 1.8 V or 3 V voltage supply. Depending on whether the device
has a x8 or x16 bus width, the page size is 2112 bytes (2048 + 64 spare) or or 1056 words
(1024 + 32 spare), respectively.
The address lines are multiplexed with the data input/output signals on a multiplexed x8
input/output bus. This interface reduces the pin count and makes it possible to migrate to
other densities without changing the footprint.
Each block can be programmed and erased over 100 000 cycles with ECC (error correction
code) on. To extend the lifetime of NAND Flash devices, the implementation of an ECC is
strongly recommended.
A Write Protect pin is available to provide hardware protection against program and erase
operations.
The devices feature an open-drain ready/busy output that identifies if the P/E/R
(program/erase/read) Controller is currently active. The use of an open-drain output allows
the ready/busy pins from several memories to connect to a single pull-up resistor.
A Copy Back Program command is available to optimize the management of defective
blocks. When a page program operation fails, the data can be programmed in another page
without having to resend the data to be programmed. An embedded error detection code is
automatically executed after each copy back operation: 1 error bit can be detected for every
528 bits. With this feature it is no longer necessary, nor recommended, to use an external 2-
bit ECC to detect copy back operation errors.
The devices have a cache read feature that improves the read throughput for large files.
During cache reading, the device loads the data in a Cache Register while the previous data
is transferred to the I/O buffers to be read.
The devices have the Chip Enable ‘don’t care’ feature, which allows code to be directly
downloaded by a microcontroller. This is possible because Chip Enable transitions during
the latency time do not stop the read operation.
Both the NAND04G-B2D and NAND08G-BxC support the ONFI 1.0 specification.
7/69
Description
NAND04G-B2D, NAND08G-BxC
Two further features are available as options:
●
Extra non-volatile protection.
An individual serial number that acts as an unique identifier.
●
More information is available, upon completion of an NDA (non-disclosure agreement), and
therefore, the details are not described in this datasheet. For more information on these two
options, contact your nearest Numonyx Sales office.
The devices are available in the TSOP48 (12 x 20 mm) and LGA52 (12 x 17 mm) packages.
To meet environmental requirements, Numonyx offers the NAND04G-B2D and NAND08G-
BxC in ECOPACK® packages.
For information on how to order these options, refer to Table 34: Ordering information
scheme. Devices are shipped from the factory with block 0 always valid and the memory
content bits, in valid blocks, erased to ’1’.
Table 2: Product description lists the part numbers and other information for all the devices
able in the family.
Table 2.
Product description
Timings
Bus
width
Page
size
Block
size
Memory Operating
Part Number
Density
Package
Sequential
access
Random
access
Page
Program Erase
Block
array
voltage
time (min) time (max)
(typ)
(typ)
1.7 to
1.95 V
NAND04GR3B2D
NAND04GW3B2D
NAND04GR4B2D
NAND04GW4B2D
NAND08GR3B2C
NAND08GW3B2C
NAND08GR4B2C
NAND08GW4B2C
NAND08GR3B4C
NAND08GW3B4C
45 ns
LGA52
2048+64
bytes
128 K+
4 K bytes
x8
x16
x8
2.7 to
3.6 V
TSOP48
LGA52
25 ns
25 µs
45 ns
64 pages
x 4096
blocks
4 Gb
200 µs
1.5ms
1.7 to
1.95 V
1024+
32 words 2 K words
64 K +
(1)
2.7 to
3.6 V
25 ns
45 ns
25 ns
1.7 to
1.95 V
(2)
LGA52
2048+64
bytes
128 K +
4 K bytes
2.7 to
3.6 V
TSOP48
(2)
LGA52
1.7 to
1.95 V
45 ns
25 µs
25 ns
64 pages
x 8192
blocks
1024+
32 words 2 K words
64 K +
(1)(2)
8 Gb
x16
200 µs
1.5ms
2.7 to
3.6 V
1.7 to
1.95 V
x8
x8
45 ns
25 ns
2048+64
bytes
128 K +
4 K bytes
(2)
LGA52
2.7 to
3.6 V
1. x16 organization is only available for MCP products.
2. The NAND08G-BxC is composed of two 4-Gbit dice.
8/69
NAND04G-B2D, NAND08G-BxC
Description
Figure 1.
Logic block diagram
Address
Register/Counter
AL
CL
W
NAND Flash
Memory Array
P/E/R Controller,
High Voltage
Generator
Command
Interface
Logic
E
WP
R
Page Buffer
Cache Register
Y Decoder
Command Register
I/O Buffers & Latches
RB
I/O0-I/O7 (x8/x16)
I/O8-I/O15 (x16)
AI13166b
1. The NAND08G-B4C devices have two separate sets of signals for each 4 Gb die.
Figure 2.
Logic diagram
V
DD
I/O0-I/O7 (x8/x16)
I/O8-I/O15 (x16)
E
R
W
NAND FLASH
RB
AL
CL
WP
V
SS
AI13167b
1. The NAND08G-B4C devices have two separate sets of signals for each 4 Gb die.
9/69
Description
NAND04G-B2D, NAND08G-BxC
Direction
(1)
Table 3.
Signal
Signal names
Function
Data input/outputs, address inputs, or command inputs (x8/x16
devices)
I/O0-7
Input/output
I/O8-15
AL
Data input/outputs (x16 devices)
Address Latch Enable
Command Latch Enable
Chip Enable
Input/output
Input
CL
Input
E
Input
R
Read Enable
Input
RB
W
Ready/Busy (open-drain output)
Write Enable
Output
Input
WP
VDD
VSS
NC
DU
Write Protect
Input
Supply Voltage
Power supply
Ground
N/A
Ground
Not connected internally
Do not use
N/A
1. The NAND08G-B4C devices have two separate sets of signals for each 4 Gb die.
10/69
NAND04G-B2D, NAND08G-BxC
Figure 3. TSOP48 connections for NAND04G-B2D and NAND08G-BxC
Description
NC
NC
NC
NC
NC
NC
RB
R
1
48
NC
NC
NC
NC
I/O7
I/O6
I/O5
I/O4
NC
E
NC
NC
NC
NC
V
12
13
37
36
V
V
DD
DD
SS
NAND FLASH
V
SS
NC
NC
CL
AL
NC
NC
NC
I/O3
I/O2
I/O1
I/O0
W
WP
NC
NC
NC
NC
NC
NC
NC
NC
NC
24
25
AI13168b
11/69
Description
NAND04G-B2D, NAND08G-BxC
Figure 4.
LGA52 connections for NAND04G-B2D and NAND08G-B2C devices
0
1
2
3
4
5
6
7
8
OA
OB
NC
NC
NC
NC
A
B
C
NC
CL
E
NC
V
V
DD
SS
NC
NC
AL
R
D
E
OC
NC
NC
NC
NC
NC
NC
W
RB
NC
F
WP
V
SS
I/O7
I/O5
G
NC
I/O0
I/O2
NC
NC
NC
H
J
I/O1
I/O3
I/O6
I/O4
NC
NC
NC
NC
NC
OD
OE
OF
NC
NC
NC
K
L
V
SS
M
N
V
V
SS
DD
NC
NC
NC
NC
AI13634b
12/69
NAND04G-B2D, NAND08G-BxC
Description
Figure 5.
LGA52 connections for the NAND08G-B4C devices
0
1
2
3
4
5
6
7
8
OA
OB
NC
NC
NC
A
NC
AL
CL
E
NC
1
2
1
2
NC
NC
B
C
V
V
DD
SS
CL
W
E
R
1
1
D
E
OC
NC
AL
R
2
2
W
RB
2
RB
2
1
1
F
WP
V
SS
1
G
I/O0
I/O1
I/O2
I/O0
I/O2
V
I/O7
I/O6
I/O5
WP
2
2
2
1
2
2
2
2
H
J
I/O1
I/O3
V
I/O7
I/O5
V
1
1
I/O6
1
1
NC
NC
NC
OD
OE
OF
NC
NC
NC
K
L
1
1
I/O4
1
SS
M
N
SS
DD
I/O4
NC
I/O3
NC
2
2
1. The NAND08G-B4C devices have two separate sets of signals for each 4 Gb die.
13/69
Memory array organization
NAND04G-B2D, NAND08G-BxC
2
Memory array organization
The memory array of the devices is made up of NAND structures where 32 cells are
connected in series. It is organized into blocks where each block contains 64 pages. The
array is split into two areas, the main area, and the spare area. The main area of the array is
used to store data, and the spare area typically stores error correction codes, software flags,
or bad block identification.
In x8 devices, the pages are split into a 2048-byte main area and a spare area of 64 bytes.
In x16 devices, the pages are split into a 1024-word main area and a spare area of 32
words. Refer to Figure 6: Memory array organization.
Bad blocks
In the x8 devices, the NAND Flash 2112 byte/1056 word page devices may contain bad
blocks, which are blocks that contain one or more invalid bits whose reliability is not
guaranteed. Additional bad blocks may develop during the lifetime of the device.
The bad block information is written prior to shipping (refer to Section 9.1: Bad block
management for more details).
Table 4 shows the minimum number of valid blocks. The values shown include both the bad
blocks that are present when the device is shipped and the bad blocks that could develop
later on. Block 0 is guaranteed to be valid up to 1000 write/erase cycles with 1 bit ECC.
These blocks need to be managed using bad blocks management, block replacement, or
error correction codes (refer to Section 9: Software algorithms).
Table 4.
Valid Blocks
Density of Device
Min
Max
4 Gbits
4016
8032
4096
8192
8 Gbits(1)
1. The NAND08G-BxC devices are composed of two 4-Gbit dice. The minimum number of valid blocks is
4016 for each die.
14/69
NAND04G-B2D, NAND08G-BxC
Figure 6. Memory array organization
Memory array organization
x8 bus width
Plane = 2048 blocks, block = 64 pages, page = 2112 bytes (2048 + 64)
First plane
Second plane
Spare area
Spare area
Main area
Main area
Block
Page
8 bits
2048 bytes
2048 bytes
64
bytes
64
bytes
Page buffer, 2112 bytes
64
Page buffer, 2112 bytes
64
2048 bytes
2,048 bytes
bytes
bytes
8 bits
2-page buffer, 2 x 2112 bytes
x16 bus width
Plane = 2048 blocks, block = 64 pages, page = 1056 words (1024 + 32)
First plane
Second plane
Spare area
Spare area
Main area
Main area
Block
Page
16 bits
1024 words
1024 words
32
words
32
words
Page buffer, 1056 bytes
32
Page buffer, 1056 bytes
32
1024 words
1024 words
words
words
16 bits
AI13170b
2-page buffer, 2 x 1056 bytes
15/69
Signal descriptions
NAND04G-B2D, NAND08G-BxC
3
Signal descriptions
See Figure 2: Logic diagram and Table 3: Signal names for a brief overview of the signals
connected to this device. The NAND08G-B4C devices have two separate sets of signals for
each 4 Gb die.
3.1
3.2
Inputs/outputs (I/O0-I/O7)
Input/outputs 0 to 7 input the selected address, output the data during a read operation, or
input a command or data during a write operation. The inputs are latched on the rising edge
of Write Enable. I/O0-I/O7 are left floating when the device is deselected or the outputs are
disabled.
Inputs/Outputs (I/O8-I/O15)
Input/Outputs 8 to 15 are only available in x16 devices. They output the data during a read
operation or input data during a write operation. Command and address inputs only require
I/O0 to I/O7.
The inputs are latched on the rising edge of Write Enable. I/O8-I/O15 are left floating when
the device is deselected or the outputs are disabled.
3.3
3.4
3.5
Address Latch Enable (AL)
The Address Latch Enable activates the latching of the address inputs in the Command
Interface. When AL is high, the inputs are latched on the rising edge of Write Enable.
Command Latch Enable (CL)
The Command Latch Enable activates the latching of the command inputs in the Command
Interface. When CL is high, the inputs are latched on the rising edge of Write Enable.
Chip Enable (E)
The Chip Enable input, E, activates the memory control logic, input buffers, decoders and
sense amplifiers. When Chip Enable is low, V , the device is selected. If Chip Enable goes
IL
high, V , while the device is busy, the device remains selected and does not go into standby
IH
mode.
3.6
Read Enable (R)
The Read Enable pin, R, controls the sequential data output during read operations. Data is
valid t
after the falling edge of R. The falling edge of R also increments the internal
RLQV
column address counter by one.
16/69
NAND04G-B2D, NAND08G-BxC
Signal descriptions
3.7
Write Enable (W)
The Write Enable input, W, controls writing to the Command Interface, input address and
data latches. Both addresses and data are latched on the rising edge of Write Enable.
During power-up and power-down a recovery time of 10 µs (min) is required before the
command interface is ready to accept a command. It is recommended to keep Write Enable
high during the recovery time.
3.8
3.9
Write Protect (WP)
The Write Protect pin is an input that gives a hardware protection against unwanted program
or erase operations. When Write Protect is Low, V , the device does not accept any
program or erase operations.
IL
It is recommended to keep the Write Protect pin Low, V , during power-up and power-down.
IL
Ready/Busy (RB)
The Ready/Busy output, RB, is an open-drain output that identifies if the P/E/R Controller is
currently active.
When Ready/Busy is Low, V , a read, program or erase operation is in progress. When the
OL
operation completes, Ready/Busy goes High, V
.
OH
The use of an open-drain output allows the ready/busy pins from several memories to be
connected to a single pull-up resistor. A Low then indicates that one or more of the
memories is busy.
During power-up and power-down a minimum recovery time of 10 µs is required before the
command interface is ready to accept a command. During this period the RB signal is Low,
V
.
OL
Refer to Section 12.1: Ready/Busy signal electrical characteristics for details on how to
calculate the value of the pull-up resistor.
3.10
3.11
VDD supply voltage
V
provides the power supply to the internal core of the memory device. It is the main
DD
power supply for all operations (read, program and erase).
An internal voltage detector disables all functions whenever V is below V
Table 29) to protect the device from any involuntary program/erase during power-transitions.
(see
LKO
DD
Each device in a system should have V decoupled with a 0.1 µF capacitor. The PCB track
widths should be sufficient to carry the required program and erase currents.
DD
VSS ground
Ground, V
ground.
is the reference for the power supply. It must be connected to the system
SS,
17/69
Bus operations
NAND04G-B2D, NAND08G-BxC
4
Bus operations
There are six standard bus operations that control the memory, as described in this section.
See Table 5: Bus operations for a summary of these operations.
Typically, glitches of less than 5 ns on Chip Enable, Write Enable, and Read Enable are
ignored by the memory and do not affect bus operations.
4.1
Command input
Command input bus operations give commands to the memory.
Commands are accepted when Chip Enable is Low, Command Latch Enable is High,
Address Latch Enable is Low, and Read Enable is High. They are latched on the rising edge
of the Write Enable signal.
Only I/O0 to I/O7 are used to input commands.
See Figure 25 and Table 30 for details of the timings requirements.
4.2
Address input
Address input bus operations input the memory addresses. Five bus cycles are required to
input the addresses (refer to Table 6: Address insertion (x8 devices) and Table 7: Address
insertion (x16 devices)).
The addresses are accepted when Chip Enable is Low, Address Latch Enable is High,
Command Latch Enable is Low, and Read Enable is High. They are latched on the rising
edge of the Write Enable signal.
Only I/O0 to I/O7 are used to input addresses.
See Figure 26 and Table 30 for details of the timings requirements.
4.3
Data input
Data input bus operations input the data to be programmed.
Data is accepted only when Chip Enable is Low, Address Latch Enable is Low, Command
Latch Enable is Low, and Read Enable is High. The data is latched on the rising edge of the
Write Enable signal. The data is input sequentially using the Write Enable signal.
See Figure 27 and Table 30 and Table 31 for details of the timings requirements.
4.4
Data output
Data output bus operations read the data in the memory array, the Status Register, the
electronic signature, and the unique identifier.
Data is output when Chip Enable is Low, Write Enable is High, Address Latch Enable is Low,
and Command Latch Enable is Low.
The data is output sequentially using the Read Enable signal.
18/69
NAND04G-B2D, NAND08G-BxC
If the Read Enable pulse frequency is lower then 33 MHz (t
Bus operations
higher than 30 ns), the
RLRL
output data is latched on the rising edge of Read Enable signal (see Figure 28).
For higher frequencies (t lower than 30 ns), the EDO (extended data out) mode must be
RLRL
used. In this mode, data output bus operations are valid on the input/output bus for a time of
after the falling edge of Read Enable signal (see Figure 29).
t
RLQX
See Table 31 for details on the timings requirements.
4.5
4.6
Write protect
Write protect bus operations protect the memory against program or erase operations.
When the Write Protect signal is Low the device does not accept program or erase
operations, and, therefore, the contents of the memory array cannot be altered. The Write
Protect signal is not latched by Write Enable to ensure protection, even during power-up.
Standby
When Chip Enable is High the memory enters Standby mode, the device is deselected,
outputs are disabled, and power consumption is reduced.
Table 5.
Bus operation
Command input VIL
Bus operations
E
AL
CL
R
W
WP
I/O0 - I/O7
I/O8 - I/O15(1)
VIL
VIH
VIL
VIL
X
VIH
VIL
VIL
VIL
X
VIH
VIH
VIH
Falling
X
Rising
Rising
Rising
VIH
X(2)
X
Command
Address
Data input
Data output
X
X
Address input
Data input
VIL
VIL
VIL
X
X
VIH
Data input
Data output
Write protect
Standby
X
Data output
X
VIL
X
X
VIH
X
X
X
X
VIL/VDD
X
1. Only for x16 devices.
2. WP must be VIH when issuing a program or erase command.
Table 6.
Address insertion (x8 devices)
Bus
I/O7
I/O6
I/O5
I/O4
I/O3
I/O2
I/O1
I/O0
Cycle(1)
1st
2nd
3rd
4th
5th
A7
VIL
A6
VIL
A5
VIL
A4
VIL
A3
A11
A15
A23
VIL
A2
A10
A1
A9
A0
A8
A19
A27
VIL
A18
A26
VIL
A17
A25
VIL
A16
A24
VIL
A14
A13
A21
A29
A12
A20
A28
A22
A30(2)
1. Any additional address input cycles are ignored.
2. A30 is only valid for the NAND08G-BxC devices.
19/69
Bus operations
NAND04G-B2D, NAND08G-BxC
Table 7.
Address insertion (x16 devices)
Bus
I/O7
I/O6
I/O5
I/O4
I/O3
I/O2
I/O1
I/O0
Cycle(1)
1st
2nd
3rd
4th
5th
A7
VIL
A6
VIL
A5
VIL
A4
VIL
A3
VIL
A2
A10
A1
A9
A0
A8
A18
A26
VIL
A17
A25
VIL
A16
A24
VIL
A15
A23
VIL
A14
A22
VIL
A13
A12
A20
A28
A11
A19
A27
A21
A29(2)
1. Any additional address input cycles are ignored.
2. A29 is only valid for the NAND08G-BxC devices.
Table 8.
Address definition (x8 devices)
Address
Definition
A0 - A11
A12 - A17
A18 - A29
A18 - A30
A18 = 0
Column address
Page address
Block address(NAND04G-B2D)
Block address (NAND08G-BxC)
First plane
A18 = 1
Second plane
Table 9.
Address definition (x16 devices)
Address
Definition
A0 - A10
A11 - A16
A17 - A28
A17 - A29
A18 = 0
Column address
Page address
Block address (NAND04G-B2D)
Block address (NAND08G-BxC)
First plane
A18 = 1
Second plane
20/69
NAND04G-B2D, NAND08G-BxC
Command set
5
Command set
All bus write operations to the device are interpreted by the command interface. The
commands are input on I/O0-I/O7 and are latched on the rising edge of Write Enable when
the command Latch Enable signal is high. Device operations are selected by writing specific
commands to the Command Register. The two-step command sequences for program and
erase operations are imposed to maximize data security.
Table 10 summarizes the commands.
Table 10. Commands
Bus write operations
Commands
accepted
during busy
Command(1)
1st cycle 2nd cycle 3rd cycle 4th cycle
Read
00h
05h
31h
00h
3Fh
30h
E0h
–
–
–
–
–
–
–
–
–
–
–
Random Data Output
Cache Read (sequential)
Enhanced Cache Read (random)
Exit Cache Read
31h
–
Yes(2)
Page Program
80h
10h
–
–
(sequential input default)
Random Data Input
85h
80h
80h
00h
85h
85h
85h
60h
60h
60h
FFh
90h
70h
78h
ECh
7Bh
–
11h
11h
35h
10h
11h
11h
D0h
60h
D1h
–
–
81h
80h
–
–
10h
10h
–
Multiplane Page Program(3)
Multiplane Page Program
Copy Back Read
Copy Back Program
–
–
Multiplane Copy Back Program(3)
Multiplane Copy Back Program
Block Erase
81h
85h
–
10h
10h
–
Multiplane Block Erase(3)
Multiplane Block Erase
Reset
D0h
60h
–
–
D0h
–
Yes
Read Electronic Signature
Read Status Register
Read Status Enhanced
Read Parameter Page
Read EDC Status Register
–
–
–
–
–
–
Yes
–
–
–
Yes
–
–
–
–
–
–
1. Commands in bold are referring to ONFI 1.0 specifications.
2. Only during cache read busy.
3. Command maintained for backward compatibility.
21/69
Device operations
NAND04G-B2D, NAND08G-BxC
6
Device operations
This section provides details of the device operations.
6.1
Read memory array
At power-up the device defaults to read mode. To enter read mode from another mode, the
Read command must be issued (see Table 10: Commands).
6.1.1
6.1.2
Random read
Each time the Read command is issued, the first read is random read.
Page read
After the first random read access, the page data (2112 bytes or 1056 words) are
transferred to the page buffer in a time of t
(see Table 31 ). Once the transfer is
WHBH
complete, the Ready/Busy signal goes High. The data can then be read sequentially (from
selected column address to last column address) by pulsing the Read Enable signal.
The device can output random data in a page, instead of consecutive sequential data, by
issuing a Random Data Output command. The Random Data Output command can be used
to skip some data during a sequential data output.
The sequential operation can be resumed by changing the column address of the next data
to be output, to the address which follows the Random Data Output command. The Random
Data Output command can be issued as many times as required within a page.
The Random Data Output command is not accepted during cache read operations.
22/69
NAND04G-B2D, NAND08G-BxC
Device operations
Figure 7.
Read operations
CL
E
W
AL
R
tBLBH1
30h
RB
I/O
Address Input
00h
Data Output (sequentially)
Command
Code
Command
Code
Busy
ai12469
23/69
Device operations
NAND04G-B2D, NAND08G-BxC
Figure 8.
Random data output during sequential data output
tBLBH1
(Read Busy time)
RB
Busy
tRHWL
W
R
Address
Address
Inputs
30h
E0h
I/O
00h
05h
Data Output
Data Output
Inputs
Cmd
Cmd
Cmd
Cmd
Code
Code
Code
Code
5 Add cycles
2 Add cycles
Col Add 1,2
Row Add 1,2,3 Col Add 1,2
Spare
Area
Spare
Main Area
Main Area
Area
ai08658b
6.2
Cache read
The cache read operation improves the read throughput by reading data using the Cache
Register. As soon as the user starts to read one page, the device automatically loads the
next page into the Cache Register.
A Read Page command, as defined in Section 6.1.1: Random read, is issued prior to the
first Read Cache command in a read cache sequence. Once the data output of the Page
Read command terminates, the Cache Read command can be issued as follows:
1. Issue a Sequential Cache Read command to copy the next page in sequential order to
the Cache Register.
2. Issue a Random Cache Read command to copy the page addressed in this command
to the Cache Register.
The two commands can be used interchangeably, in any order. When there are no more
pages are to be read, the final page is copied into the Cache Register by issuing the Exit
Cache Read command. A Read Cache Command must not be issued after the last page of
the device is read.
See Figure 9: Cache read (sequential) operation and Figure 10: Cache read (random)
operation for examples of the two sequences.
24/69
NAND04G-B2D, NAND08G-BxC
Device operations
After the Sequential Cache Read or Random Cache Read command has been issued, the
Ready/Busy signal goes Low and the Status Register bits are set to SR5 =' 0' and SR6 ='0'
for a period of Cache Read busy time, t
Cache Register.
, while the device copies the next page into the
RCBSY
After the cache read busy time has passed, the Ready/Busy signal goes High and the
Status Register bits are set to SR5 = '0' and SR6 = '1', signifying that the Cache Register is
ready to download new data. Data of the previously read page can be output from the page
buffer by toggling the Read Enable signal. Data output always begins at column address
00h, but the Random Data Output command is also supported.
Figure 9.
Cache read (sequential) operation
tBLBH1
tRCBSY
tRCBSY
(Read Busy time)
(Read Cache Busy time)
(Read Cache Busy time)
RB
R
Busy
Data
Data
Outputs
Address
Inputs
31h
I/O0-7
30h
00h
3Fh
Exit
Cache
Read
Code
Outputs
Read
Setup
Code
Read
Code
Cache
Read
Sequential
Code
ai13176b
Repeat as many times as ncessary.
Figure 10. Cache read (random) operation
tBLBH1
tRCBSY
tRCBSY
(Read Busy time)
(Read Cache Busy time)
(Read Cache Busy time)
RB
R
Busy
Address
31h
Data
Outputs
Address
Data
Outputs
00h
3Fh
Exit
Cache
Read
Code
I/O0-7
30h
00h
Inputs
Inputs
Read
Setup
Code
Read
Code
Read
Setup
Code
Enhanced
Cache
Read
(random)
Code
ai13176c
Repeat as many times as ncessary.
25/69
Device operations
NAND04G-B2D, NAND08G-BxC
6.3
Page program
The page program operation is the standard operation to program data to the memory array.
Generally, the page is programmed sequentially, however, the device does support random
input within a page.
It is recommended to address pages sequentially within a given block.
The memory array is programmed by page, however, partial page programming is allowed
where any number of bytes (1 to 2112) or words (1 to 1056) can be programmed.
The maximum number of consecutive, partial-page program operations allowed in the same
page is four. After exceeding four operations a Block Erase command must be issued before
any further program operations can take place in that page.
6.3.1
Sequential input
To input data sequentially the addresses must be sequential and remain in one block.
For sequential input each page program operation consists of the following five steps :
1. One bus cycle is required to set up the Page Program (sequential input) command (see
Table 10: Commands).
2. Five bus cycles are then required to input the program address (refer to Table 6:
Address insertion (x8 devices) and Table 7: Address insertion (x16 devices)).
3. The data is then loaded into the Data Registers.
4. One bus cycle is required to issue the Page Program Confirm command to start the
P/E/R Controller. The P/E/R only starts if the data has been loaded in step 3.
5. the P/E/R Controller then programs the data into the array.
See Figure 11: Page program operation for more information.
6.3.2
Random data input in page
During a sequential input operation, the next sequential address to be programmed can be
replaced by a random address by issuing a Random Data Input command. The following
two steps are required to issue the command:
1. One bus cycle is required to set up the Random Data Input command (see Table 10:
Commands).
2. Two bus cycles are then required to input the new column address (refer to Table 6:
Address insertion (x8 devices)).
Random data input can be repeated as often as required in any given page.
Once the program operation has started, the Status Register can be read using the Read
Status Register command. During program operations the Status Register only flags errors
for bits set to '1' that have not been successfully programmed to '0'.
During the program operation, only the Read Status Register and Reset commands are
accepted; all other commands are ignored.
Once the program operation has completed, the P/E/R Controller bit SR6 is set to ‘1’ and
the Ready/Busy signal goes High.
The device remains in Read Status Register mode until another valid command is written to
the command interface.
26/69
NAND04G-B2D, NAND08G-BxC
Device operations
Figure 11. Page program operation
tBLBH2
(Program Busy time)
RB
I/O
Busy
Data Input
10h
Address Inputs
80h
70h
SR0
Confirm
Code
Read Status Register
Page Program
Setup Code
ai08659
Figure 12. Random data input during sequential data input
tBLBH2
(Program Busy time)
RB
Busy
Address
Inputs
Address
Inputs
I/O
80h
85h
10h
Data Intput
Data Input
70h
SR0
Cmd
Code
Cmd
Confirm
Code
Read Status Register
Code 2 Add cycles
5 Add cycles
Col Add 1,2
Row Add 1,2,3 Col Add 1,2
Spare
Area
Spare
Area
Main Area
Main Area
ai08664
27/69
Device operations
NAND04G-B2D, NAND08G-BxC
6.4
Multiplane page program
The devices support multiplane page program, which enables the programming of two
pages in parallel, one in each plane.
A multiplane page program operation requires the following two steps:
1. The first step serially loads up to two pages of data (4224 bytes) into the data buffer. It
requires:
–
–
–
–
One clock cycle to set up the Page Program command (see Section 6.3.1:
Sequential input).
5 bus write cycles to input the first page address and data. The address of the first
page must be within the first plane (A18 = 0).
One bus write cycle to issue the Page Program Confirm code. After this, the
device is busy for a time of t
IPBSY.
When the device returns to the ready state (Ready/Busy High), a multiplane page
program setup code must be issued, followed by the 2nd page address (5 write
cycles) and data. The address of the 2nd page must be within the second plane
(A18 = 1).
2. The 2nd step programs in parallel the two pages of data loaded into the data buffer into
the appropriate memory pages. It is started by issuing a the Program Confirm
command.
As for standard page program operation, the device supports random data input during both
data loading phases.
Once the multiplane page program operation has started, that is during a delay of t
Status Register can be read using the Read Status Register command.
, the
IPBSY
Once the multiplane page program operation has completed, the P/E/R Controller bit SR6 is
set to ‘1’ and the Ready/Busy signal goes High.
If the multiplane page program fails, an error is signaled on bit SR0 of the Status Register.
To know which page of the two planes failed, the Read Status Enhanced command must be
issued twice, once for each plane (see Section 6.12).
Figure 13 provides a description of multiplane page program waveforms.
Figure 13. Multiplane page program waveform
tIPBSY
tBLBH2
(Program Busy time)
RB
Busy
Busy
(1)
I/O
Data Input
11h
Data Input
10h
Address Inputs
A18=0
Address Inputs
A18=1
80h
70h
SR0
80h
Confirm
Code
Multiplane Page
Program Setup
code
Confirm
Code
Read Status Register
Page Program
Setup Code
ai13171b
1. The 81h setup code is also accepted for backward compatibility.
28/69
NAND04G-B2D, NAND08G-BxC
Device operations
6.5
Copy back program
The copy back program operation copies the data stored in one page and reprograms it in
another page.
The copy back program operation does not require external memory and so the operation is
faster and more efficient because the reading and loading cycles are not required. The
operation is particularly useful when a portion of a block is updated and the rest of the block
needs to be copied to the newly assigned block.
The NAND04G-B2D and NAND08G-BxC devices feature automatic EDC during a copy
back operation. Consequently, external ECC is no longer required. The errors detected
during copy back operations can be read by performing a read EDC Status Register
operation (see Section 6.13: Read EDC Status Register). See also Section 6.9 for details of
EDC operations.
The copy back program operation requires the following four steps:
1. The first step reads the source page. The operation copies all 2112 bytes from the
page into the data buffer. It requires:
–
–
–
One bus write cycle to set up the command
5 bus write cycles to input the source page address
One bus write cycle to issue the confirm command code
2. When the device returns to the ready state (Ready/Busy High), optional data readout is
allowed by pulsing R; the next bus write cycle of the command is given with the 5 bus
cycles to input the target page address. See Table 11 for the addresses that must be
the same for the source and target page.
3. Issue the confirm command to start the P/E/R Controller.
To see the data input cycle for modifying the source page and an example of the copy back
program operation, refer to Figure 14: Copy back program (without readout of data).
Figure 16: Page copy back program with random data input shows a data input cycle to
modify a portion or a multiple distant portion of the source page.
Table 11. Copy back program addresses
Density
Source and target page addresses
4 Gbits
8 Gbits
Same A18
Same A18 and A30
Figure 14. Copy back program (without readout of data)
Source
Add Inputs
Target
Add Inputs
I/O
10h
70h
SR0
35h
85h
00h
Read
Code
Copy Back
Code
Read Status Register
tBLBH1
tBLBH2
(Read Busy time)
(Program Busy time)
RB
Busy
Busy
ai09858b
1. Copy back program is only permitted between odd address pages or even address pages.
29/69
Device operations
NAND04G-B2D, NAND08G-BxC
Figure 15. Copy back program (with readout of data)
Source
Target
I/O
10h
70h
SR0
35h
85h
00h
Data Outputs
Add Inputs
Add Inputs
Read
Code
Copy Back
Code
Read Status
Register
tBLBH1
tBLBH2
(Read Busy time)
(Program Busy time)
RB
Busy
Busy
ai09858c
Figure 16. Page copy back program with random data input
2 Cycle
Target
Add Inputs
Source
Add Inputs
I/O
35h
SR0
00h
85h
Data 85h
Data 10h
70h
Add Inputs
Read
Code
Copy Back
Code
Unlimited number of repetitions
tBLBH1
tBLBH2
(Read Busy time)
(Program Busy time)
RB
Busy
Busy
ai11001
6.6
Multiplane copy back program
In addition to multiplane page program, the NAND04G-B2D and NAND08G-BxC devices
support multiplane copy back program.
A Multiplane Copy Back Program command requires exactly the same steps as a Multiplane
Page Program command, and must satisfy the same time constraints (see Section 6.4:
Multiplane page program).
Prior to executing the multiplane copy back program operation, two single-page read
operations must be executed to copy back the first page from the first plane and the second
page from the second plane.
The EDC check is also performed during the multiplane copy back program. Errors during
multiplane copy back operations can be detected by performing a Read EDC Status
Register operation (see Section 6.13: Read EDC Status Register).
If the multiplane copy back program fails, an error is signaled on bit SR0 of the Status
Register. To know which page of the two planes failed, the Read Status Enhanced
command must be executed twice, once for each plane (see Section 6.12).
30/69
NAND04G-B2D, NAND08G-BxC
Device operations
Figure 17 provides a description of multiplane copy back program waveform.
Figure 17. Multiplane copy back program
Source
Source
(1)
Target
Target
85h
I/O
35h
10h
Read Status Register
tBLBH2
70h SR0
35h
00h
85h
11h
00h
Add Inputs
A18=0
Add Inputs
Add Inputs
Add Inputs
Read
Code
Read
Code
Copy Back
Code
Copy Back
Code
A18 = 1
A18 = 0
A18 = 1
tBLBH1
tBLBH1
tIPBSY
(Read Busy time)
(Read Busy time)
(Program Busy time)
RB
Busy
Busy
Busy
Busy
ai13172b
1. The 81h setup code is also accepted for backward compatibility.
6.7
Block erase
Erase operations are done one block at a time. An erase operation sets all of the bits in the
addressed block to ‘1’. All previous data in the block is lost.
An erase operation consists of the following three steps (refer to Figure 18: Block erase):
1. One bus cycle is required to set up the Block Erase command. Only addresses A18-
A29 are used; all other address inputs are ignored.
2. Three bus cycles are then required to load the address of the block to be erased. Refer
to Table 8: Address definition (x8 devices) for the block addresses of each device.
3. One bus cycle is required to issue the Block Erase Confirm command to start the P/E/R
Controller.
The operation is initiated on the rising edge of Write Enable, W, after the Confirm command
is issued. The P/E/R Controller handles block erase and implements the verify process.
During the block erase operation, only the Read Status Register and Reset commands are
accepted; all other commands are ignored.
Once the program operation has completed, the P/E/R Controller bit SR6 is set to ‘1’ and
the Ready/Busy signal goes High. If the operation completed successfully, the Write Status
bit SR0 is ‘0’, otherwise it is set to ‘1’.
Figure 18. Block erase
tBLBH3
(Erase Busy time)
RB
Busy
Block Address
Inputs
I/O
60h
D0h
70h
SR0
Confirm
Code
Read Status Register
Block Erase
Setup Code
ai07593
31/69
Device operations
NAND04G-B2D, NAND08G-BxC
6.8
Multiplane block erase
The multiplane block erase operation allows the erasure of two blocks in parallel, one in
each plane.
This operation consists of the following three steps (refer to Figure 19: Multiplane block
erase):
1. 8 bus cycles are required to set up the Block Erase command and load the addresses
of the blocks to be erased. The setup command followed by the address of the block to
be erased must be issued for each block. t
busy time is required between the
IEBSY
insertion of first and the second block addresses. As for multiplane page program
operations, the address of the first and second page must be within the first plane (A18
= 0) and second plane (A8 = 1), respectively.
2. One bus cycle is then required to issue the Multiplane Block Erase Confirm command
and start the P/E/R Controller.
If the multiplane block erase fails, an error is signaled on bit SR0 of the Status Register. To
know which page of the two planes failed, the Read Status Enhanced command must be
issued twice, once for each plane (see Section 6.12).
Figure 19. Multiplane block erase
tBLBH3
tIEBSY
(Erase Busy time)
RB
I/O
Busy
(1)
D1h
Block Address
Inputs
Block Address
Inputs
60h
60h
D0h
70h
SR0
Block Erase
Setup Code
A18 = 0
Multiplane Block Block Erase
Erase Code Setup Code
A18 = 1
Confirm
Code
Read Status
Register
ai13173b
1. The D1h Confirm code is required by the ONFI 1.0 command set. To maintain backward compatibility, the D1h Confirm
code can optionally be ignored, and then the tIEBSY Busy Time does not occur.
6.9
Error detection code (EDC)
The EDC (error detection code) is performed automatically during all program operations. It
starts immediately after the device becomes busy.
The EDC detects 1 single bit error per EDC unit. Each EDC unit has a density of 528 bytes
(or 264 words), split into 512 bytes of main area and 16 bytes of spare area (or 256 + 8
words). Refer to Table 12 and Figure 20 for EDC unit addresses definition.
To properly use the EDC, the following conditions apply:
●
●
Page program operations must be performed on a whole page, or on whole EDC
unit(s).
The modification of the content of an EDC unit using a random data input before the
copy back program, must be performed on the whole EDC unit. It can only be done
once per EDC unit. Any partial modification of the EDC unit results in the corruption of
the on-chip EDCs.
32/69
NAND04G-B2D, NAND08G-BxC
Device operations
EDC results can be retrieved only during copy back program and multiplane copy back
using the Read EDC Status Register command (see Section 6.13).
Figure 20. Page organization
Page = 4 EDC units
Main area (2048 bytes/1024 words)
Spare area (64 bytes/32 words)
A area
B area
C area
D area
E area
F area
G area
H area
(512 bytes/ (512 bytes/ (512 bytes/ (512 bytes/ (16 bytes/ (16 bytes/ (16 bytes/ (16 bytes/
256 words) 256 words) 256 words) 256 words) 8 words)
8 words) 8 words)
8 words)
AI13179b
Table 12. Address definition for EDC units (x8 devices)
Main area
EDC unit
Spare area
Area name
Column address
Area name
Column address
1st 528-byte EDC unit
2nd 528-byte EDC unit
3rd 528-byte EDC unit
4th 528-byte EDC unit
A
B
C
D
0 to 511
E
F
2048 to 2063
2064 to 2079
2080 to 2095
2096 to 2111
512 to 1023
1024 to1535
1536 to 2047
G
H
Table 13. Address definition for EDC units (x16 devices)
Main area
EDC unit
Spare area
Area name
Column address
Area name
Column address
1st 264-word EDC unit
2nd 264-word EDC unit
3rd 264-word EDC unit
4th 264-word EDC unit
A
B
C
D
0 to 255
256 to 511
512 to 767
768 to 1023
E
F
1024 to 1031
1032 to 1039
1040 to 1047
1048 to 1055
G
H
6.10
Reset
The Reset command is used to reset the command interface and Status Register. If the
Reset command is issued during any operation, the operation is aborted. If the aborted
operation is a program or erase, the contents of the memory locations being modified are no
longer valid as the data is partially programmed or erased.
If the device has already been reset, then the new Reset command is not accepted.
The Ready/Busy signal goes Low for t
after the Reset command is issued. The value
BLBH4
of t
depends on the operation that the device was performing when the command was
BLBH4
issued. Refer to Table 31 for the values.
33/69
Device operations
NAND04G-B2D, NAND08G-BxC
6.11
Read Status Register
The devices contain a Status Register that provides information on the current or previous
program or erase operation. The various bits in the Status Register convey information and
errors on the operation.
The Status Register is read by issuing the Read Status Register command. The Status
Register information is present on the output data bus (I/O0-I/O7) on the falling edge of Chip
Enable or Read Enable, whichever occurs last. When several memories are connected in a
system, the use of Chip Enable and Read Enable signals allows the system to poll each
device separately, even when the Ready/Busy pins are common-wired. It is not necessary to
toggle the Chip Enable or Read Enable signals to update the contents of the Status
Register.
After the Read Status Register command has been issued, the device remains in Read
Status Register mode until another command is issued. Therefore, if a Read Status Register
command is issued during a Random Read cycle, a new Read command must be issued to
continue with a page read operation.
The Status Register bits are summarized in Table 14: Status Register bits. Refer to Table 14
in conjunction with the following sections.
6.11.1
6.11.2
Write protection bit (SR7)
The write protection bit identifies if the device is protected or not. If the write protection bit is
set to ‘1’, the device is not protected and program or erase operations are allowed. If the
write protection bit is set to ‘0’ the device is protected and program or erase operations are
not allowed.
P/E/R Controller and cache ready/busy bit (SR6)
Status Register bit SR6 has two different functions depending on the current operation.
During cache operations, SR6 acts as a cache ready/busy bit, which indicates whether the
Cache Register is ready to accept new data. When SR6 is set to '0', the Cache Register is
busy, and when SR6 is set to '1', the Cache Register is ready to accept new data.
During all other operations, SR6 acts as a P/E/R Controller bit, which indicates whether the
P/E/R Controller is active or inactive. When the P/E/R Controller bit is set to ‘0’, the P/E/R
Controller is active (device is busy); when the bit is set to ‘1’, the P/E/R Controller is inactive
(device is ready).
6.11.3
P/E/R Controller bit (SR5)
The Program/Erase/Read Controller bit indicates whether the P/E/R Controller is active or
inactive during cache operations. When the P/E/R Controller bit is set to ‘0’, the P/E/R
Controller is active (device is busy); when the bit is set to ‘1’, the P/E/R Controller is inactive
(device is ready).
Note:
This bit is only valid for cache operations.
6.11.4
Error bit (SR0)
The error bit identifies if any errors have been detected by the P/E/R Controller. The error bit
is set to ’1’ when a program or erase operation has failed to write the correct data to the
memory. If the error bit is set to ‘0’ the operation has completed successfully.
34/69
NAND04G-B2D, NAND08G-BxC
Device operations
6.11.5
SR4, SR3, SR2 and SR1 are reserved
Table 14. Status Register bits
Bit
Name
Logic level
Definition
'1'
'0'
'1'
'0'
'1'
'0'
Not protected
Protected
SR7
Write protection
P/E/R Controller inactive, device ready
P/E/R Controller active, device busy
P/E/R Controller inactive, device ready
P/E/R Controller active, device busy
Program/Erase/Read
Controller
SR6
SR5
Program/Erase/Read
Controller(1)
SR4, SR3,
SR2, SR1
Reserved
‘don’t care’
‘1’
‘0’
Error – operation failed
SR0
Generic error
No error – operation successful
1. Only valid for cache operations.
6.12
Read status enhanced
In NAND Flash devices with multiplane architecture, it is possible to independently read the
Status Register of a single plane using the Read Status Enhanced command. If the Error bit
of the Status Register, SR0, reports an error during or after a multiplane operation, the Read
Status Enhanced command is used to know which of the two planes contains the page that
failed the operation. Three address cycles are required to address the selected block and
page (A18-0).
The output of the Read Status Enhanced command has the same coding as the Read
Status command. See Table 14 for a full description and Figure 31 for the read status
enhanced waveform.
6.13
Read EDC Status Register
The devices contain an EDC Status Register, which provides information on the errors that
occurred during the read cycles of the copy back and multiplane copy back operations. In
the case of multiplane copy back program, it is not possible to distinguish which of the two
read operations caused the error.
The EDCS Status Register is read by issuing the Read EDC Status Register command.
After issuing the Read EDC Status Register command, a read cycle outputs the content of
the EDC Status Register to the I/O pins on the falling edge of Chip Enable or Read Enable
signals, whichever occurs last. The operation is similar to Read Status Register command.
Table 15: EDC Status Register bits summarizes the EDC Status Register bits. See
Figure 30 for a description of Read EDC Status Register waveforms.
35/69
Device operations
NAND04G-B2D, NAND08G-BxC
Definition
Table 15. EDC Status Register bits
Bit
Name
Logic level
Copy back or multiplane copy back
operation failed
‘1’
0
Pass/fail
Copy back or multiplane copy back
operation succeeded
‘0’
‘1’
Error
1
2
EDC status
EDC validity
‘0’
No error
Valid
‘1’
‘0’
Invalid
-
3
4
Reserved
Reserved
‘don’t care’
‘don’t care’
-
‘1’
‘0’
‘1’
‘0’
‘1’
‘0’
Ready
Busy
5
6
7
Ready/busy(1)
Ready/busy(1)
Write protect
Ready
Busy
Not protected
Protected
1. See Table 14: Status Register bits for a description of SR5 and SR6 bits.
6.14
Read electronic signature
The devices contain a manufacturer code and device code. The following three steps are
required to read these codes:
1. One bus write cycle to issue the Read Electronic Signature command (90h)
2. One bus write cycle to input the address (00h)
3. Five bus read cycles to sequentially output the data (as shown in Table 16: Electronic
signature).
36/69
NAND04G-B2D, NAND08G-BxC
Table 16. Electronic signature
Device operations
Byte 5
Byte 3
Byte 4
Root part number
Byte 1
Byte 2
(see Table 17)
(see Table 18)
(see Table 19)
NAND04GR3B2D
20h
20h
ACh
DCh
10h
10h
15h
54h
NAND08GR3B4C(1)
NAND04GW3B2D
95h
54h
NAND08GW3B4C(1)
NAND04GR4B2D
NAND04GW4B2D
NAND08GR3B2C
NAND08GW3B2C
NAND08GR4B2C
NAND08GW4B2C
0020h
0020h
20h
BCh
CCh
A3h
D3h
B3h
C3h
10h
10h
51h
51h
51h
51h
55h
D5h
15h
95h
55h
D5h
54h
54h
58h
58h
58h
58h
20h
0020h
0020h
1. For NAND08G-B4C devices, each 4 Gb die returns its own electronic signature.
Table 17. Electronic signature byte 3
I/O
Definition
Value
Description
0 0
0 1
1 0
1 1
1
2
4
8
I/O1-I/O0
Internal chip number
0 0
0 1
1 0
1 1
2-level cell
4-level cell
8-level cell
I/O3-I/O2
I/O5-I/O4
Cell type
16-level cell
0 0
0 1
1 0
1 1
1
2
4
8
Number of simultaneously
programmed pages
0
1
Not supported
Supported
Interleaved programming
between multiple devices
I/O6
I/O7
0
1
Not supported
Supported
Cache program
37/69
Device operations
NAND04G-B2D, NAND08G-BxC
Description
Table 18. Electronic signature byte 4
I/O
Definition
Value
0 0
0 1
1 0
1 1
1 Kbytes
2 Kbytes
4 Kbytes
8 Kbytes
Page size
I/O1-I/O0
(without spare area)
Spare area size
(byte/512 byte)
0
1
8
I/O2
16
0 0
1 0
0 1
1 1
30/50 ns
25 ns
Minimum sequential access
time
I/O7, I/O3
Reserved
Reserved
0 0
0 1
1 0
1 1
64 Kbytes
128 Kbytes
256 Kbytes
512 Kbytes
Block size
I/O5-I/O4
I/O6
(without spare area)
0
1
x8
Organization
x16
Table 19. Electronic signature byte 5
I/O
Definition
Value
Description
I/O1 - I/O0
Reserved
0 0
0 0
0 1
1 0
1 1
1 plane
2 planes
4 planes
8 planes
I/O3 - I/O2
Plane number
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
64 Mbits
128 Mbits
256 Mbits
512 Mbits
1 Gb
Plane size
I/O6 - I/O4
(without spare area)
2 Gb
4 Gb
8 Gb
I/O7
Reserved
0
38/69
NAND04G-B2D, NAND08G-BxC
Device operations
6.15
Read ONFI signature
To recognize NAND Flash devices that are compatible with the ONFI 1.0 command set, the
Read Electronic Signature can be issued, followed by an address of 20h. The next four
bytes output is the ONFI signature, which is the ASCII encoding of the “ONFI” word.
Reading beyond four bytes produces indeterminate values.
Figure 33 provides a description of the read ONFI signature waveform and Table 20
provides the definition of the output bytes.
Table 20. Read ONFI signature
Byte
Value
ASCII character
1st byte
2nd byte
3rd byte
4th byte
5th byte
4Fh
4Eh
O
N
46h
F
49h
I
Undefined
Undefined
6.16
Read parameter page
The Read Parameter Page command retrieves the data structure that describes the NAND
Flash organization, features, timings and other behavioral parameters. This data structure
enables the host processor to automatically recognize the NAND Flash configuration of a
device. The whole data structure is repeated at least five times.
See Figure 40 for a description of the read parameter page waveform.
The Random Data Read command can be issued during execution of the read parameter
page to read specific portions of the parameter page.
The Read Status command may be used to check the status of read parameter page during
execution. After completion of the Read Status command, 00h is issued by the host on the
command line to continue with the data output flow for the Read Parameter Page command.
Read status enhanced is not be used during execution of the Read Parameter Page
command.
Table 21 defines the parameter page data structure; for parameters that span multiple bytes,
the least significant byte of the parameter corresponds to the first byte.
Values are reported in the parameter page in bytes when referring to items related to the
size of data access (as in an x8 data access device). For example, the chip returns how
many data bytes are in a page. For a device that supports x16 data access, the host is
required to convert byte values to word values for its use. Unused fields are set to 0h.
For more detailed information about parameter page data bits, refer to ONFI
Specification 1.0, section 5.4.1.
39/69
Device operations
NAND04G-B2D, NAND08G-BxC
Table 21. Parameter page data structure
Byte
O/M(1)
Description
Parameter page signature
– Byte 0: 4Fh, "O"
– Byte 1: 4Eh, "N"
– Byte 2: 46h, "F"
– Byte 3: 49h, "I"
0-3
M
Revision number
Bit 2 to bit 15 Reserved (0)
4-5
M
Bit 1
Bit 0
1 = supports ONFI version 1.0
Reserved (0)
Features supported
Bit 5 to bit 15 Reserved (0)
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1 = supports odd to even page copyback
6-7
M
1 = supports interleaved operations
1 = supports non-sequential page programming
1 = supports multiple LUN operations
1 = supports 16-bit data bus width
Optional commands supported
Bit 6 to bit 15 Reserved (0)
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1 = supports Read Unique ID
1 = supports Copyback
8-9
M
1 = supports Read Status Enhanced
1 = supports Get Features and Set Features
1 = supports Read Cache commands
1 = supports Page Cache Program command
Reserved (0)
10-31
32-43
44-63
64
M
M
M
O
Device manufacturer (12 ASCII characters)
Device model (20 ASCII characters)
JEDEC manufacturer ID
65-66
67-79
80-83
84-85
86-89
90-91
92-95
Date code
Reserved (0)
M
M
M
M
M
Number of data bytes per page
Number of spare bytes per page
Number of data bytes per partial page
Number of spare bytes per partial page
Number of pages per block
40/69
NAND04G-B2D, NAND08G-BxC
Table 21. Parameter page data structure (continued)
Device operations
Byte
O/M(1)
Description
96-99
100
M
M
Number of blocks per logical unit (LUN)
Number of logical units (LUNs)
Number of address cycles
101
M
Bit 4 to bit 7
Bit 0 to bit 3
Column address cycles
Row address cycles
102
103-104
105-106
107
M
M
M
M
M
M
Number of bits per cell
Bad blocks maximum per LUN
Block endurance
Guaranteed valid blocks at beginning of target
Block endurance for guaranteed valid blocks
Number of programs per page
108-109
110
Partial programming attributes
Bit 5 to bit 7
4
Reserved
1 = partial page layout is partial page data followed by
partial page spare
111
M
Bit 1 to bit 3
0
Reserved
1 = partial page programming has constraints
Number of bits ECC correctability
112
113
M
M
Number of interleaved address bits
Bit 4 to bit 7
Bit 0 to bit 3
Reserved (0)
Number of interleaved address bits
Interleaved operation attributes
Bit 4 to bit 7
Bit 3
Reserved (0)
Address restrictions for program cache
1 = program cache supported
1 = no block address restrictions
Overlapped/concurrent interleaving support
Reserved (0)
114
O
M
Bit 2
Bit 1
Bit 0
115-127
128
I/O pin capacitance
41/69
Device operations
NAND04G-B2D, NAND08G-BxC
Table 21. Parameter page data structure (continued)
Byte
O/M(1)
Description
Timing mode support
Bit 6 to bit 15 Reserved (0)
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1 = supports timing mode 5
1 = supports timing mode 4
1 = supports timing mode 3
1 = supports timing mode 2
1 = supports timing mode 1
1 = supports timing mode 0, shall be 1
129-130
M
Program cache timing mode support
Bit 6 to bit 15 Reserved (0)
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1 = supports timing mode 5
1 = supports timing mode 4
1 = supports timing mode 3
1 = supports timing mode 2
1 = supports timing mode 1
1 = supports timing mode 0
tPROG maximum page program time (µs)
131-132
O
133-134
135-136
137-138
139-163
164-165
166-253
254-255
256-511
512-767
M
M
M
M
M
M
M
M
M
t
BERS maximum block erase time (µs)
tR maximum page read time (µs)
Reserved (0)
Vendor specific revision number
Vendor specific
Integrity CRC
Value of bytes 0-255
Value of bytes 0-255
768+
O
Additional redundant parameter pages
1. O = optional, M = mandatory
42/69
NAND04G-B2D, NAND08G-BxC
Concurrent operations and extended read status
7
Concurrent operations and extended read status
The NAND08G-BxC devices are composed of two 4-Gbit dice stacked together. This
configuration allows the devices to support concurrent operations, which means that while
performing an operation in one die (erase, read, program, etc.), another operation is
possible in the other die.
The standard Read Status Register operation returns the status of the NAND08G-BxC
device. To provide information on each 4-Gbit die, the NAND08G-BxC devices feature an
Extended Read Status Register command that independently checks the status of each
NAND04G-B2D.
The following steps are required to perform concurrent operations:
1. Select one of the two dice by setting the most significant address bit A30 to ‘0’ or ‘1’.
2. Execute one operation on this die.
3. Launch a concurrent operation on the other die.
4. Check the status of these operations by performing an Extended Read Status Register
operation.
All combinations of operations are possible except read while read. This is due to the fact
that the input/output bus is common to both dice.
Refer to Table 22 for the description of the Extended Read Status Register command
sequence, and to Table 14. for the definition of the Status Register bits.
Table 22. Extended Read Status Register commands
Command
Address range
1 bus write cycle
Read 1st die status
Read 2nd die status
Address ≤0x3FFFFFFF
F2h
F3h
0x3FFFFFFF < Address ≤0x7FFFFFF
8
Data protection
The devices feature a Write Protect, WP, pin, which can be used to protect the device
against program and erase operations. It is recommended to keep WP at V during power-
IL
up and power-down.
43/69
Software algorithms
NAND04G-B2D, NAND08G-BxC
9
Software algorithms
This section provides information on the software algorithms that Numonyx recommends
implementing to manage the bad blocks and extend the lifetime of the NAND device.
NAND Flash memories are programmed and erased by Fowler-Nordheim tunnelling using
high voltage. Exposing the device to high voltage for extended periods damages the oxide
layer.
To extend the number of program and erase cycles and increase the data retention, the:
●
●
Number of program and erase cycles is limited (see Table 24: Program erase times and
program erase endurance cycles for the values)
Implementation of a garbage collection, a wear-leveling algorithm and an error
correction code is recommended.
To help integrate a NAND memory into an application, Numonyx provides a file system OS
native reference software, which supports the basic commands of file management.
Contact the nearest Numonyx sales office for more details.
9.1
Bad block management
Devices with bad blocks have the same quality level and the same AC and DC
characteristics as devices that have all valid blocks. A bad block does not affect the
performance of valid blocks because it is isolated from the bit and common source lines by a
select transistor.
The devices are supplied with all the locations inside valid blocks erased (FFh). The bad
block information is written prior to shipping. Any block, where the 1st and 6th bytes or the
1st word in the spare area of the 1st page, does not contain FFh, is a bad block.
The bad block information must be read before any erase is attempted as the bad block
Information may be erased. For the system to be able to recognize the bad blocks based on
the original information, the creation of a bad block table following the flowchart shown in
Figure 21: Bad block management flowchart is recommended.
44/69
NAND04G-B2D, NAND08G-BxC
Software algorithms
9.2
NAND Flash memory failure modes
Over the lifetime of the device bad blocks may develop. To implement a highly reliable
system, the possible failure modes must be considered.
●
Program/erase failure
In this case, the block has to be replaced by copying the data to a valid block. These
additional bad blocks can be identified because attempts to program or erase them
gives errors in the Status Register. As the failure of a page program operation does not
affect the data in other pages in the same block, the block can be replaced by
reprogramming the current data and copying the rest of the replaced block to an
available valid block. The Copy Back Program command can be used to copy the data
to a valid block. See Section 6.5: Copy back program for more details.
●
Read failure
In this case, ECC correction must be implemented. To efficiently use the memory
space, the recovery of a single-bit error in read by ECC, without replacing the whole
block, is recommended.
Refer to Table 23: Block failure for the recommended procedure to follow if an error occurs
during an operation.
Table 23. Block failure
Operation
Procedure
Erase
Program
Read
Block replacement
Block replacement or ECC
ECC
Figure 21. Bad block management flowchart
START
Block Address =
Block 0
Increment
Block Address
Update
Bad Block table
Data
= FFh?
NO
NO
YES
Last
block?
YES
END
AI07588C
45/69
Software algorithms
NAND04G-B2D, NAND08G-BxC
9.3
Garbage collection
When a data page needs to be modified, it is faster to write to the first available page,
resulting in the previous page being marked as invalid. After several updates it is necessary
to remove invalid pages to free memory space.
To free this memory space and allow further program operations, the implementation of a
garbage collection algorithm is recommended. In garbage collection software, the valid
pages are copied into a free area and the block containing the invalid pages is erased as
show in Figure 22.
Figure 22. Garbage collection
Old Area
New Area (After GC)
Valid
Page
Invalid
Page
Free
Page
(Erased)
AI07599B
9.4
Wear-leveling algorithm
For write-intensive applications, the implementation of a wear-leveling algorithm is
recommended to monitor and spread the number of write cycles per block.
In memories that do not use a wear-leveling algorithm, not all blocks get used at the same
rate. The wear-leveling algorithm ensures that equal use is made of all the available write
cycles for each block. There are two wear-leveling levels:
●
First level wear-leveling, where new data is programmed to the free blocks that have
had the fewest write cycles.
●
Second level wear-leveling, where long-lived data is copied to another block so that the
original block can be used for more frequently-changed data.
The second level wear-leveling is triggered when the difference between the maximum and
the minimum number of write cycles per block reaches a specific threshold.
46/69
NAND04G-B2D, NAND08G-BxC
Software algorithms
9.5
Error correction code
An ECC can be implemented in the NAND Flash memories to identify and correct errors in
the data. For every 2048 bits in the device, the implementation of 22 bits of ECC (16 bits for
line parity plus 6 bits for column parity) is recommended.
Figure 23. Error detection
New ECC generated
during read
XOR previous ECC
with new ECC
NO
NO
>1 bit
= zero?
All results
= zero?
YES
YES
22 bit data = 0
11 bit data = 1
1 bit data = 1
ECC Error
Correctable
Error
No Error
ai08332
47/69
Program and erase times and endurance cycles
NAND04G-B2D, NAND08G-BxC
10
Program and erase times and endurance cycles
The program and erase times and the number of program/erase cycles per block are shown
in Table 24.
Table 24. Program erase times and program erase endurance cycles
NAND Flash
Parameters
Unit
Min
Typ
Max
Page Program/Multiplane Program time
Block Erase/Multiplane Erase time
Multiplane Program time (1.8 V)
Multiplane Erase (1.8 V)
200
1.5
250
2
700
2
µs
ms
800
2.5
1
µs
ms
Multiplane Program Busy time (tIPBSY
Multiplane Erase Busy time (tIEBSY
Cache Read Busy time (tRCBSY
)
0.5
0.5
3
µs
)
1
µs
)
tR
µs
Program/erase cycles per block (with ECC)
Data retention
100 000
10
Cycles
Years
48/69
NAND04G-B2D, NAND08G-BxC
Maximum ratings
11
Maximum ratings
Stressing the device above the ratings listed in Table 25: Absolute maximum ratings may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the operating sections of
this specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability. Refer to the Numonyx SURE Program and
other relevant quality documents for more information.
Table 25. Absolute maximum ratings
Value
Symbol
Parameter
Unit
Min
Max
TBIAS
TSTG
Temperature under bias
– 50
– 65
– 0.6
– 0.6
125
150
4.6
°C
°C
V
Storage temperature
Input or output voltage
Supply voltage
(1)
VIO
VDD
4.6
V
1. Minimum voltage may undershoot to –2 V for less than 20 ns during transitions on input and I/O pins.
Maximum voltage may overshoot to VDD + 2 V for less than 20 ns during transitions on I/O pins.
49/69
DC and AC parameters
NAND04G-B2D, NAND08G-BxC
12
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the devices. The parameters in the following DC and AC characteristics
tables are derived from tests performed under the measurement conditions summarized in
Table 26. Designers should check that the operating conditions in their circuit match the
measurement conditions when relying on the quoted parameters.
Table 26. Operating and AC measurement conditions
NAND Flash
Parameter
Units
Min
Max
Supply voltage (VDD
)
2.7
0
3.6
70
85
V
Grade 1
Grade 6
°C
°C
pF
pF
V
Ambient temperature (TA)
–40
30
50
0
1.8 V device
3.0 V device
Load capacitance (CL) (1 TTL GATE
and CL)
Input pulses voltages
VDD
Input and output timing ref. voltages
Output circuit resistor Rref
Input rise and fall times
VDD/2
8.35
5
V
kΩ
ns
(1)
Table 27. Capacitance
Symbol
Parameter
Test condition
Typ
Max
Unit
CIN
Input capacitance
VIN = 0V
10
pF
Input/output
CI/O
VIL = 0V
10
pF
capacitance(2)
1.
TA = 25°C, f = 1MHz. CIN and CI/O are not 100% tested.
2. Input/output capacitances double in stacked devices.
50/69
NAND04G-B2D, NAND08G-BxC
DC and AC parameters
Figure 24. Equivalent testing circuit for AC characteristics measurement
V
DD
2R
ref
NAND Flash
C
L
2R
ref
GND
GND
Ai11085
Table 28. DC characteristics (1.8 V devices)
Symbol
Parameter
Test conditions
Min
Typ
Max
Unit
tRLRL minimum
Sequential
read
IDD1
-
10
20
mA
E=VIL, OUT = 0 mA
I
Operating
current
IDD2
IDD3
Program
Erase
-
-
-
-
10
10
20
20
mA
mA
E=VDD-0.2,
WP=0/VDD
IDD5
Standby current (CMOS(1)
)
-
10
50
µA
ILI
ILO
Input leakage current(1)
Output leakage current(1)
Input high voltage
VIN= 0 to VDDmax
VOUT= 0 to VDDmax
-
-
-
-
-
-
-
-
-
10
µA
µA
V
-
10
VIH
0.8 * VDD
VDD + 0.3
VIL
Input low voltage
-
-0.3
0.2 * VDD
V
VOH
VOL
Output high voltage level
Output low voltage level
Output low current (RB)
IOH = -100 µA
IOL = 100 µA
VOL = 0.1 V
VDD - 0.1
-
0.1
4
V
-
V
IOL (RB)
3
mA
VDD supply voltage (erase and
program lockout)
VLKO
-
-
-
1.2
V
1. Leakage current and standby current double in stacked devices.
51/69
DC and AC parameters
NAND04G-B2D, NAND08G-BxC
Table 29. DC characteristics (3 V devices)
Symbol
Parameter
Test conditions
Min
Typ
Max
Unit
tRLRL minimum
Sequential
read
IDD1
-
15
30
mA
E = VIL, OUT = 0 mA
I
Operating
current
IDD2
IDD3
Program
Erase
-
-
-
-
15
15
30
30
1
mA
mA
mA
I
Standby current (TTL)(1)
E = VIH, WP = 0/VDD
DD4
E = VDD-0.2,
WP = 0/VDD
IDD5
Standby current (CMOS)(1)
-
10
50
µA
ILI
ILO
Input leakage current(1)
Output leakage current(1)
Input High voltage
VIN= 0 to VDDmax
VOUT= 0 to VDDmax
-
-
-
-
-
-
-
-
-
10
10
µA
µA
V
-
VIH
0.8 VDD
VDD+0.3
0.2 VDD
-
VIL
Input Low voltage
-
-0.3
2.4
-
V
VOH
VOL
Output High voltage Level
Output Low voltage Level
Output Low current (RB)
IOH = -400 µA
IOL = 2.1 mA
VOL = 0.4 V
V
0.4
V
IOL (RB)
8
10
mA
VDD supply voltage (erase and
program lockout)
VLKO
-
-
-
1.8
V
1. leakage current and standby current double in stacked devices.
Table 30. AC characteristics for command, address, data input
Alt.
Symbol
Parameter
1.8 V
25
3 V
12
Unit
ns
Symbol
tALLWH
tALHWH
tCLHWH
tCLLWH
tDVWH
tELWH
Address Latch Low to Write Enable high
Address Latch High to Write Enable high
Command Latch High to Write Enable high
Command Latch Low to Write Enable high
Data Valid to Write Enable High
tALS
AL setup time
CL setup time
Min
tCLS
Min
25
12
ns
tDS
tCS
Data setup time
E setup time
AL hold time
Min
Min
Min
20
35
10
12
20
5
ns
ns
ns
Chip Enable Low to Write Enable high
Write Enable High to Address Latch High
Write Enable High to Command Latch High
Write Enable High to Command Latch Low
Write Enable High to Data Transition
Write Enable High to Chip Enable High
Write Enable High to Write Enable Low
Write Enable Low to Write Enable High
Write Enable Low to Write Enable Low
tWHALH
tWHCLH
tWHCLL
tWHDX
tWHEH
tWHWL
tWLWH
tWLWL
tALH
tCLH
CL hold time
Min
10
5
ns
tDH
tCH
tWH
tWP
tWC
Data hold time
E hold time
Min
Min
10
10
15
25
45
5
ns
ns
ns
ns
ns
5
W high hold time Min
10
12
25
W pulse width
Min
Min
Write cycle time
52/69
NAND04G-B2D, NAND08G-BxC
DC and AC parameters
(1)
Table 31. AC characteristics for operations
Alt.
Symbol
Parameter
1.8 V
3 V
Unit
symbol
tALLRL1
tALLRL2
tBHRL
Read electronic signature
Read cycle
Min
Min
10
10
20
25
700
2
10
10
20
25
700
2
ns
ns
ns
µs
µs
ms
µs
µs
µs
µs
ns
ns
ns
Address Latch Low to
Read Enable Low
tAR
tRR
Ready/Busy High to Read Enable Low
Read Busy time
Min
tBLBH1
tBLBH2
tBLBH3
Max
Max
Max
Max
Max
Max
Max
Min
tPROG
tBERS
Program Busy time
Erase Busy time
Ready/Busy Low to
Ready/Busy High
Reset Busy time, during ready
5
5
Reset Busy time, during read
Reset Busy time, during program
Reset Busy time, during erase
5
5
tBLBH4
tRST
10
500
10
0
10
500
10
0
tCLLRL
tDZRL
tCLR
tIR
Command Latch Low to Read Enable Low
Data Hi-Z to Read Enable Low
Min
tEHQZ
tEHALX
tEHCLX
tRHQZ
tELQV
tCHZ
Chip Enable High to Output Hi-Z
Max
30
30
Chip Enable High to Address Latch ‘don’t care’
Chip Enable High to Command Latch ‘don’t care’
Read Enable High to Output Hi-z
tCSD
Min
10
10
ns
tRHZ
tCEA
Max
Max
100
45
100
25
ns
ns
Chip Enable Low to Output Valid
Read Enable High to
Read Enable High Hold time
Read Enable Low
tRHRL
tREH
tCOH
Min
15
10
ns
tEHQX
tRHQX
tRLQX
Chip Enable high to Output Hold
Min
Min
Min
15
15
5
15
15
5
ns
ns
ns
tRHOH Read Enable High to Output Hold
tRLOH Read Enable Low to Output Hold (EDO mode)
Read Enable Low to
tRLRH
tRLRL
tRP
Read Enable pulse width
Min
Min
25
45
12
25
ns
ns
Read Enable High
Read Enable Low to
Read Enable Low
tRC
Read cycle time
Read Enable access time
Read ES access time(2)
Read Enable Low to
Output Valid
tRLQV
tREA
Max
Max
30
25
20
25
ns
µs
Write Enable High to
Ready/Busy High
tWHBH
tR
Read Busy time
tWHBL
tWHRL
tRHWL
tWB
Write Enable High to Ready/Busy Low
Write Enable High to Read Enable Low
Max
Min
Min
100
60
100
60
ns
ns
ns
tWHR
tRHW Read Enable High to Write Enable Low
100
100
53/69
DC and AC parameters
Table 31. AC characteristics for operations (continued)
NAND04G-B2D, NAND08G-BxC
(1)
Last address latched to data loading time during program
operations
(3)
tWHWH
tADL
Min
Min
100
100
70
ns
ns
tVHWH
tVLWH
(4)
tWW
Write protection time
100
1. The time to Ready depends on the value of the pull-up resistor tied to the Ready/Busy pin. See Figure 41, Figure 42 and
Figure 43.
2. ES = Electronic Signature.
3. tADL is the time from W rising edge during the final address cycle to W rising edge during the first data cycle.
4. During a Program/Erase Enable Operation, tWW is the delay from WP high to W High.
During a Program/Erase Disable Operation, tWW is the delay from WP Low to W High.
Figure 25. Command latch AC waveforms
CL
tCLHWH
tWHCLL
(CL Setup time)
(CL Hold time)
tWHEH
tELWH
H(E Setup time)
(E Hold time)
E
tWLWH
W
tALLWH
tWHALH
(ALSetup time)
(AL Hold time)
AL
I/O
tDVWH
tWHDX
(Data Setup time)
(Data Hold time)
Command
ai12470b
54/69
NAND04G-B2D, NAND08G-BxC
DC and AC parameters
Figure 26. Address latch AC waveforms
tCLLWH
(CL Setup time)
CL
tWLWL
tELWH
(E Setup time)
tWLWL
tWLWL
tWLWL
E
tWLWH
tWLWH
tWLWH
tWLWH
tWLWH
W
tWHWL
tWHWL
tWHWL
tWHWL
tWHALL
tALHWH
(AL Setup time)
tWHALL
tWHALL
tWHALL
(AL Hold time)
AL
I/O
tDVWH
tDVWH
tDVWH
tWHDX
tDVWH
tWHDX
tDVWH
(Data Setup time)
tWHDX
tWHDX
tWHDX
ai12471
(Data Hold time)
Adrress
cycle 3
Adrress
cycle 2
Adrress
cycle 4
Adrress
cycle 5
Adrress
cycle 1
Figure 27. Data input latch AC waveforms
tWHCLH
(CL Hold time)
CL
E
tWHEH
(E Hold time)
tALLWH
(ALSetup time)
tWLWL
AL
tWLWH
tWLWH
tWLWH
W
tDVWH
tDVWH
tWHDX
tDVWH
tWHDX
(Data Setup time)
tWHDX
(Data Hold time)
Data In
Last
I/O
Data In 0
Data In 1
ai12472
1. The last data input is the 2112th.
55/69
DC and AC parameters
NAND04G-B2D, NAND08G-BxC
Figure 28. Sequential data output after read AC waveforms
tRLRL
(Read Cycle time)
E
tEHQX
tEHQZ
tRHRL
(R High Holdtime)
R
tRHQZ
tRHQZ
(2)
tRHQX
tRLQV
tRLQV
tRLQV
(R Accesstime)
I/O
RB
Data Out
Data Out
Data Out
tBHRL
ai13174
1. CL = Low, AL = Low, W = High.
2. tRHQX is applicable for frequencies lower than 33MHz (i.e. tRLRL higher than 30ns).
Figure 29. Sequential data output after read AC waveforms (EDO mode)
tRLRL
E
tEHQX
tEHQZ
tRLRH
tRLQV
tRHRL
R
tRHQZ
(2)
tELQV
tRLQX
tRLQV
tRHQX
(R Accesstime)
I/O
RB
Data Out
Data Out
Data Out
tBHRL
ai13175
1. In EDO mode, CL and AL are Low, VIL, and W is High, VIH
.
2. tRLQX is applicable for frequencies high than 33 MHz (i.e. tRLRL lower than 30 ns).
56/69
NAND04G-B2D, NAND08G-BxC
DC and AC parameters
Figure 30. Read Status Register or read EDC Status Register AC waveform
tCLLRL
CL
tWHCLL
tCLHWH
tWHEH
E
tELWH
tWLWH
W
R
tELQV
tRLQV
tEHQZ
tEHQX
tWHRL
tDZRL
tWHDX
tRHQZ
tRHQX
tDVWH
(Data Setup time)
(Data Hold time)
Status Register
Output
I/O
70h or 7Bh
ai13177
Figure 31. Read status enhanced waveform
CL
W
AL
R
Status Register
Output
78h
Address 1 Address 2 Address 3
I/O0-7
ai14408
57/69
DC and AC parameters
NAND04G-B2D, NAND08G-BxC
Figure 32. Read Electronic Signature AC waveform
CL
E
W
AL
tALLRL1
R
tRLQV
(Read ES Access time)
I/O
90h
00h
Byte1
Byte2
Byte3
Byte4
Byte5
Man.
code
Device
code
Read Electronic 1st Cycle
see Note.1
Signature
Command
Address
ai13178
1. Refer to Table 16 for the values of the manufacturer and device codes, and to Table 17, Table 18, and Table 19 for the
information contained in byte 3, byte 4, and byte 5.
Figure 33. Read ONFI signature waveform
CL
E
W
AL
tALLRL1
R
tRLQV
(Read ES access time)
I/O
90h
20h
4Fh
4Eh
46h
49h
XXh
Read Electronic 1st cycle
Signature
command
address
ai13178b
58/69
NAND04G-B2D, NAND08G-BxC
DC and AC parameters
Figure 34. Page read operation AC waveform
tEHALX
tEHCLX
CL
E
tWLWL
tEHQZ
W
tWHBL
AL
tALLRL2
tWHBH
tRLRL
tRHQZ
(Read Cycle time)
R
tRLRH
tBLBH1
RB
Data
N
Data
N+1
Data
N+2
Data
Last
Add.N Add.N Add.N Add.N
cycle 1 cycle 2 cycle 3 cycle 4
Add.N
cycle 5
I/O
30h
00h
Data Output
from Address N to Last Byte or Word in Page
Command Address N Input
Code
Busy
ai12474b
59/69
DC and AC parameters
NAND04G-B2D, NAND08G-BxC
Figure 35. Page program AC waveform
CL
E
tWLWL
tWLWL
tWLWL
(Write Cycle time)
W
tWHBL
tWHWH
tWHRL
tBLBH2
(Program Busy time)
AL
R
Add.N Add.N
cycle 4 cycle 5
Add.N
Add.N
Add.N
I/O
RB
80h
Last
N
10h
70h
SR0
cycle 1 cycle 2
cycle 3
Confirm
Code
Page Program
Setup Code
Page
Program
Address Input
Data Input
Read Status Register
ai12475b
60/69
NAND04G-B2D, NAND08G-BxC
DC and AC parameters
Figure 36. Block erase AC waveform
CL
E
tWLWL
(Write Cycle time)
W
AL
R
tBLBH3
tWHBL
(Erase Busy time)
tWHRL
Add.
Add.
Add.
I/O
RB
70h
SR0
60h
D0h
cycle 1 cycle 2
cycle 3
Block Erase
Setup Command
Confirm
Code
Block Erase
Read Status Register
Block Address Input
ai08038c
Figure 37. Reset AC waveform
W
AL
CL
R
I/O
RB
FFh
tBLBH4
(Reset Busy time)
ai08043
61/69
DC and AC parameters
NAND04G-B2D, NAND08G-BxC
Figure 38. Program/erase enable waveform
W
tVHWH
WP
RB
I/O
80h
10h
ai12477
Figure 39. Program/erase disable waveform
W
tVLWH
WP
High
RB
I/O
80h
10h
ai12478
Figure 40. Read parameter page waveform
CL
W
AL
R
I/O0-7
R/B
ECh
00h
P0
P1
...
P0
P1
1
...
0
0
1
tBLBH1
ai14409
62/69
NAND04G-B2D, NAND08G-BxC
DC and AC parameters
12.1
Ready/Busy signal electrical characteristics
Figure 42, Figure 41 and Figure 43 show the electrical characteristics for the Ready/Busy
signal. The value required for the resistor R can be calculated using the following equation:
P
(
–
)
V
V
DDmax
OLmax
L
R min= -------------------------------------------------------------
P
+ I
I
OL
This is an example for 3 V devices:
3,2V
R min= ---------------------------
P
+
8mA
I
L
where I is the sum of the input currents of all the devices tied to the Ready/Busy signal. R
L
P
max is determined by the maximum value of t .
r
Figure 41. Ready/Busy AC waveform
ready V
DD
V
OH
V
OL
busy
t
t
f
r
AI07564B
Figure 42. Ready/Busy load circuit
ibusy
R
P
V
DD
DEVICE
RB
Open Drain Output
V
SS
AI07563B
63/69
DC and AC parameters
NAND04G-B2D, NAND08G-BxC
Figure 43. Resistor value versus waveform timings for Ready/Busy signal
V
= 3.3 V, C = 50 pF
L
DD
200
150
100
4
200
2.4
3
2
1
150
1.2
100
0.8
50
0
50
0.6
1.8
1.8
1.8
1.8
1
2
3
4
R
(KΩ)
P
t
t
ibusy
f
r
ai12476
1. T = 25°C.
12.2
Data protection
The Numonyx NAND devices aredesigned to guarantee data protection during power
transitions.
A V detection circuit disables all NAND operations, if V is below the V threshold.
LKO
DD
DD
In the V range from V
to the lower limit of nominal range, the WP pin should be kept
DD
LKO
low (V ) to guarantee hardware protection during power transitions as shown in the below
IL
figure.
Figure 44. Data protection
Nominal Range
V
DD
V
LKO
Locked
Locked
W
Ai11086
64/69
NAND04G-B2D, NAND08G-BxC
Package mechanical
13
Package mechanical
Figure 45. TSOP48 - 48 lead plastic thin small outline, 12 x 20 mm, package outline
1
48
e
D1
B
L1
24
25
A2
A
E1
E
A1
α
L
DIE
C
CP
TSOP-G
1. Drawing is not to scale.
Table 32. TSOP48 - 48 lead plastic thin small outline, 12 x 20 mm, package mechanical data
Millimeters
Min
Inches
Min
Symbol
Typ
Max
Typ
Max
A
A1
A2
B
1.200
0.150
1.050
0.270
0.210
0.080
12.100
20.200
18.500
–
0.0472
0.0059
0.0413
0.0106
0.0083
0.0031
0.4764
0.7953
0.7283
0.100
1.000
0.220
0.050
0.950
0.170
0.100
0.0039
0.0394
0.0087
0.0020
0.0374
0.0067
0.0039
C
CP
D1
E
12.000
20.000
18.400
0.500
0.600
0.800
3°
11.900
19.800
18.300
–
0.4724
0.7874
0.7244
0.0197
0.0236
0.0315
3°
0.4685
0.7795
0.7205
–
E1
e
L
0.500
0.700
0.0197
0.0276
5°
L1
a
0°
5°
0°
65/69
Package mechanical
NAND04G-B2D, NAND08G-BxC
Figure 46. LGA52 12 x 17 mm, 1 mm pitch, package outline
D
D2
D1
FD1
FD
FE1
FE
BALL "A1"
eE1
e
E
E2 E1
ddd
e
b1 b2
A2
A
LGA-9G
Table 33. LGA52 12 x 17 mm, 1 mm pitch, package mechanical data
Millimeters
Symbol
Inches
Min
Typ
Min
Max
Typ
Max
A
A2
b1
0.650
0.650
0.750
1.050
12.100
0.0256
0.0256
0.0295
0.0413
0.4764
0.700
1.000
0.650
0.950
0.0276
0.0394
0.4724
0.2362
0.3937
0.0256
0.0374
0.4685
b2
D
12.000
6.000
11.900
D1
D2
ddd
E
10.000
0.100
0.0039
0.6732
17.000
12.000
13.000
1.000
2.000
3.000
1.000
2.500
2.000
16.900
17.100
0.6693
0.4724
0.5118
0.0394
0.0787
0.1181
0.0394
0.0984
0.0787
0.6654
E1
E2
e
–
–
–
–
–
–
–
–
eE1
FD
FD1
FE
FE1
66/69
NAND04G-B2D, NAND08G-BxC
Part numbering
14
Part numbering
Table 34. Ordering information scheme
Example:
NAND04GW3B2D N
6
E
Device type
NAND Flash memory
Density
04 G = 4 Gb
08 G = 8 Gb
Operating voltage
W = VDD = 2.7 to 3.6 V
R = VDD = 1.7 to 1.95 V
Bus width
3 = x8
4 = x16(1)
Family identifier
B = 2112 byte page
Device options
2 = Chip Enable ‘don't care’ enabled
4 = Chip Enable ‘don’t care’ enabled with dual interface
Product version
C= Third version (NAND08G-BxC)
D = Fourth version (NAND04G-B2D)
Package
N = TSOP48 12 x 20 mm
ZL = LGA52 12 x 17 mm
Temperature range
1 = 0 to 70 °C
6 = –40 to 85 °C
Option
E = ECOPACK package, standard packing
F = ECOPACK package, tape and reel packing
1. x16 organization only available for MCP products
Devices are shipped from the factory with the memory content bits, in valid blocks, erased to
’1’. For further information on any aspect of this device, please contact your nearest
Numonyx Sales Office.
67/69
Revision history
NAND04G-B2D, NAND08G-BxC
15
Revision history
Table 35. Document revision history
Date
Revision
Changes
22-June-2007
1
Initial release.
Added the part numbers NAND08GR3B4C, NAND08GW3B4C,
therefore referring to the 8 Gbit devices as the NAND08G-BxC.
Modified all data throughout this document to reflect the addition
of these part numbers, namely:
17-Sep-2007
10-Dec-2007
2
3
– Table 1, Table 2, Table 6, and Table 34.
– Added Figure 5: LGA52 connections for the NAND08G-B4C
devices.
Changed VLKO value in Table 28 from 1.1 to 1.2.
Applied Numonyx branding.
68/69
NAND04G-B2D, NAND08G-BxC
Please Read Carefully:
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH NUMONYX™ PRODUCTS. NO LICENSE, EXPRESS OR
IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT
AS PROVIDED IN NUMONYX'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NUMONYX ASSUMES NO LIABILITY
WHATSOEVER, AND NUMONYX DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF
NUMONYX PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE,
MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
Numonyx products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility
applications.
Numonyx may make changes to specifications and product descriptions at any time, without notice.
Numonyx, B.V. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the
presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied,
by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights.
Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Numonyx reserves
these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
Contact your local Numonyx sales office or your distributor to obtain the latest specifications and before placing your product order.
Copies of documents which have an order number and are referenced in this document, or other Numonyx literature may be obtained by
visiting Numonyx's website at http://www.numonyx.com.
Numonyx StrataFlash is a trademark or registered trademark of Numonyx or its subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 11/5/7, Numonyx, B.V., All Rights Reserved.
69/69
相关型号:
NAND04GR3B4DN1E
4 Gbit, 8 Gbit, 2112 byte/1056 word page multiplane architecture, 1.8 V or 3 V, NAND Flash memories
NUMONYX
NAND04GR3B4DN1F
4 Gbit, 8 Gbit, 2112 byte/1056 word page multiplane architecture, 1.8 V or 3 V, NAND Flash memories
NUMONYX
NAND04GR3B4DN6E
4 Gbit, 8 Gbit, 2112 byte/1056 word page multiplane architecture, 1.8 V or 3 V, NAND Flash memories
NUMONYX
NAND04GR3B4DN6F
4 Gbit, 8 Gbit, 2112 byte/1056 word page multiplane architecture, 1.8 V or 3 V, NAND Flash memories
NUMONYX
NAND04GR3B4DZL1E
4 Gbit, 8 Gbit, 2112 byte/1056 word page multiplane architecture, 1.8 V or 3 V, NAND Flash memories
NUMONYX
NAND04GR3B4DZL1F
4 Gbit, 8 Gbit, 2112 byte/1056 word page multiplane architecture, 1.8 V or 3 V, NAND Flash memories
NUMONYX
NAND04GR3B4DZL6E
4 Gbit, 8 Gbit, 2112 byte/1056 word page multiplane architecture, 1.8 V or 3 V, NAND Flash memories
NUMONYX
NAND04GR3B4DZL6F
4 Gbit, 8 Gbit, 2112 byte/1056 word page multiplane architecture, 1.8 V or 3 V, NAND Flash memories
NUMONYX