SHT211-100707-01 [NXP]

IC SPECIALTY ANALOG CIRCUIT, PDSO6, 3 X 3 MM, 1.10 MM HEIGHT, GREEN, PLASTIC, DFN-6, Analog IC:Other;
SHT211-100707-01
型号: SHT211-100707-01
厂家: NXP    NXP
描述:

IC SPECIALTY ANALOG CIRCUIT, PDSO6, 3 X 3 MM, 1.10 MM HEIGHT, GREEN, PLASTIC, DFN-6, Analog IC:Other

光电二极管
文件: 总12页 (文件大小:487K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Datasheet SHT21  
Humidity and Temperature Sensor  
. Fully calibrated  
. Digital output, I2C interface  
. Low power consumption  
. Excellent long term stability  
. DFN type package – reflow solderable  
Product Summary  
Every sensor is individually calibrated and tested. Lot  
identification is printed on the sensor and an electronic  
identification code is stored on the chip – which can be  
read out by command. Furthermore, the resolution of  
SHT21 can be changed by command (8/12bit up to  
12/14bit for RH/T), low battery can be detected and a  
checksum helps to improve communication reliability.  
SHT21, the new humidity and temperature sensor of  
Sensirion is about to set new standards in terms of size  
and intelligence: Embedded in a reflow solderable Dual  
Flat No leads (DFN) package of 3 x 3mm foot print and  
1.1mm height it provides calibrated, linearized signals in  
digital, true I2C format.  
With a completely new designed CMOSens® chip, a  
reworked capacitive type humidity sensor and an  
improved band gap temperature sensor the performance  
has been lifted even beyond the outstanding level of the  
previous sensor generation (SHT1x and SHT7x). For  
example, measures have been taken to stabilize the  
behavior at high humidity levels.  
With made improvements and the miniaturization of the  
sensor the performance-to-price ratio has been improved  
– and eventually, any device should benefit from the  
cutting edge energy saving operation mode. For testing  
SHT21 a new evaluation Kit EK-H4 is available.  
Dimensions  
Sensor Chip  
3.0  
SHT21 features a generation 4C CMOSens® chip.  
Besides the capacitive relative humidity sensor and the  
band gap temperature sensor, the chip contains an  
amplifier, A/D converter, OTP memory and a digital  
processing unit.  
0.3 typ  
0.8 typ  
1.1  
2.2  
Material Contents  
While the sensor itself is made of Silicon the sensors’  
housing consists of a plated Cu lead-frame and green  
epoxy-based mold compound. The device is fully RoHS  
and WEEE compliant, e.g. free of Pb, Cd and Hg.  
Bottom View  
0.4  
0.3  
NC  
VDD SCL  
2.4  
Additional Information and Evaluation Kits  
Additional information such as Application Notes is  
available from the web page www.sensirion.com/sht21.  
For more information please contact Sensirion via  
info@sensirion.com.  
VSS SDA  
1.0  
1.0  
NC  
Figure 1: Drawing of SHT21 sensor package, dimensions are  
given in mm (1mm = 0.039inch), tolerances are ±0.1mm. Die  
pad (centre pad) is internally connected to VSS. NC are floating.  
VSS = GND, SDA = DATA.  
For SHT21 two Evaluation Kits are available: EK-H4, a  
four-channel device with viewer software, that also serves  
for data-logging, and a simple EK-H5 directly connecting  
one sensor via USB port to a computer.  
www.sensirion.com  
Version 1.0 – January 2010  
1/12  
Sensor Performance  
Relative Humidity1234  
Temperature567  
Parameter  
Parameter  
Condition min  
typ max Units  
Condition min  
typ  
0.01  
max Units  
12 bit  
8 bit  
typ  
0.04  
0.7  
%RH  
%RH  
14 bit  
12 bit  
typ  
°C  
°C  
°C  
°C  
°C  
Resolution 1  
Resolution 1  
0.04  
%RH  
Accuracy  
tolerance 2  
2.0  
see Figure 2  
0.1  
Accuracy  
tolerance 2  
0.3  
see Figure 3  
0.1  
max  
%RH  
max  
Repeatability  
Hysteresis  
%RH  
Repeatability  
-40  
125  
257  
30  
°C  
°F  
%RH  
1  
<0.1  
Operating Range extended 4  
-40  
5
Nonlinearity  
Response time 3  
%RH  
Response Time 7  
Long Term Drift  
s
8
s
63%  
63%  
Operating Range extended 4  
0
100 %RH  
%RH/yr  
< 0.04  
°C/yr  
Long Term Drift 5  
normal  
< 0.5  
T (°C)  
RH (%RH)  
± 10  
± 8  
± 6  
± 4  
± 2  
± 0  
± 3.0  
± 2.5  
± 2.0  
± 1.5  
± 1.0  
± 0.5  
± 0.0  
maximal tolerance  
typical tolerance  
0
10 20 30 40 50 60 70 80 90 100  
-40  
-20  
0
20  
40  
60  
80  
100  
120  
Relative Humidity (%RH)  
Temperature (°C)  
Figure 3 Maximal tolerance for temperature sensor in °C.  
Figure 2 Typical and maximal tolerance at 25°C for relative  
humidity. For extensive information see Users Guide, Sect. 1.2.  
Packaging Information  
Electrical Specification  
Sensor Type  
Packaging  
Tape & Reel  
Tape & Reel  
Tape & Reel  
Quantity  
400  
Order Number  
1-100707-01  
1-100645-01  
1-100694-01  
Parameter  
Conditions min typ max Units  
2.1 3.0 3.6  
0.15 0.4 µA  
270 300 330 µA  
0.5 1.2 µW  
0.8 0.9 1.0 mW  
1.5 µW  
5.5mW, T = + 0.5-1.5°C  
Supply Voltage, VDD  
V
SHT21  
1500  
sleep mode  
measuring  
-
Supply Current, IDD 6  
Power Dissipation 6  
5000  
sleep mode  
measuring  
-
average 8bit  
VDD = 3.0 V  
-
-
Heater  
Communication  
digital 2-wire interface, true I2C protocol  
This datasheet is subject to change and may be amended  
without prior notice.  
Table 1 Electrical specification. For absolute maximum  
values see Chapter 3 of Users Guide.  
1
Default measurement resolution is 14bit (temperature) / 12bit (humidity). It can  
be reduced to 12/8bit, 11/11bit or 13/10bit by command to user register.  
2
5
Accuracies are tested at Outgoing Quality Control at 25°C (77°F) and 3.0V.  
Value may be higher in environments with vaporized solvents, out-gassing  
Values exclude hysteresis and non-linearity and are applicable to non-  
condensing environments only.  
tapes, adhesives, packaging materials, etc. For more details please refer to  
Handling Instructions.  
3
6
Time for achieving 63% of a step function, valid at 25°C and 1 m/s airflow.  
Min and max values of Supply Current and Power Dissipation are based on  
4
fixed VDD = 3.0V and T<60°C. The average value is based on one 8bit  
measurement per second.  
Normal operating range: 0-80%RH, beyond this limit sensor may read a  
reversible offset with slow kinetics (<3%RH after 200hours at 90%RH). For more  
details please see Section 1.1 of the Users Guide.  
7
Response time depends on heat conductivity of sensor substrate.  
www.sensirion.com  
Version 1.0 – January 2010  
2/12  
Datasheet SHT21  
Users Guide SHT2x  
1 Extended Specifications  
2 Application Information  
1.1 Operating Range  
2.1 Soldering Instructions  
The sensor works stable within recommended Normal  
Range – see Figure 4. Long term exposure to conditions  
outside Normal Range, especially at humidity >80%RH,  
may temporarily offset the RH signal (+3%RH after 60h).  
After return into the Normal Range it will slowly return  
towards calibration state by itself. See Section 2.3 “Recon-  
ditioning Procedure” for eliminating the offset. Prolonged  
exposure to extreme conditions may accelerate ageing.  
The DFN’s die pad (centre pad) and perimeter I/O pads  
are fabricated from a planar copper lead-frame by over-  
molding leaving the die pad and I/O pads exposed for  
mechanical and electrical connection. Both the I/O pads  
and die pad should be soldered to the PCB. In order to  
prevent oxidation and optimize soldering, the bottom side  
of the sensor pads is plated with Ni/Pd/Au.  
On the PCB the I/O lands9 should be 0.2mm longer than  
the package I/O pads. Inward corners may be rounded to  
match the I/O pad shape. The I/O land width should match  
the DFN-package I/O-pads width 1:1 and the land for the  
die pad should match 1:1 with the DFN package – see  
Figure 6.  
100  
80  
60  
Max.  
Range  
Normal  
Range  
40  
20  
0
The solder mask10 design for the land pattern preferably is  
of type Non-Solder Mask Defined (NSMD) with solder  
mask openings larger than metal pads. For NSMD pads,  
the solder mask opening should be about 120µm to  
150µm larger than the pad size, providing a 60µm to 75µm  
design clearance between the copper pad and solder  
mask. Rounded portions of package pads should have a  
matching rounded solder mask-opening shape to minimize  
the risk of solder bridging. For the actual pad dimensions,  
each pad on the PCB should have its own solder mask  
opening with a web of solder mask between adjacent  
pads.  
-40  
-20  
0
20  
40  
60  
80  
100 120  
Temperature (°C)  
Figure 4 Operating Conditions  
1.2 RH accuracy at various temperatures  
Maximal tolerance for RH accuracy at 25°C is defined in  
Figure 2. For other temperatures maximal tolerance has  
been evaluated to be within limits displayed in Figure 58.  
0.4  
0.3  
±5  
±4  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
±6  
±5  
±5  
±7  
±8  
2.4  
±4  
±6  
±3 ±3  
±3  
±4  
±6  
±5  
±4  
±5  
±7  
1.0  
1.0  
±5  
Figure 6 Recommended metal land pattern for SHT2x. Values  
in mm. Die pad (centre pad) and NC pads may be left floating or  
be connected to ground. The outer dotted line represents the  
outer dimension of the DFN package.  
0
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80  
Temperature (°C)  
Figure 5 Maximal tolerance of relative humidity measurements  
given in %RH for temperatures 0 – 80°C.  
For solder paste printing a laser-cut, stainless steel stencil  
with electro-polished trapezoidal walls and with 0.125mm  
stencil thickness is recommended. For the I/O pads the  
stencil apertures should be 0.1mm longer than PCB pads  
and positioned with 0.1mm offset away from the centre of  
Please note that above values are maximal tolerances (not  
including hysteresis) against a high precision reference  
such as a dew point mirror. Typical deviations are at  
±2%RH where maximal tolerance is ±3%RH and about  
half the maximal tolerance at other values.  
9
The land pattern is understood to be the metal layer on the PCB, onto which  
the DFN pads are soldered to.  
8
10  
Details on how Sensirion is specifying and testing accuracy performance are  
The solder mask is understood to be the insulating layer on top of the PCB  
planned to be published on the Sensirion web page.  
covering the connecting lines.  
www.sensirion.com  
Version 1.0 – January 2010  
3/12  
Datasheet SHT21  
the package. The die pad aperture should cover about 70  
– 90% of the pad area – say up to 1.4mm x 2.3mm  
centered on the thermal land area. It can also be split in  
two openings.  
It is of great importance to understand that a humidity  
sensor is not a normal electronic component and needs to  
be handled with care. Chemical vapors at high  
concentration in combination with long exposure times  
may offset the sensor reading.  
Due to the low mounted height of the DFN, “no clean”  
type 3 solder paste11 is recommended as well as Nitrogen  
purge during reflow.  
For this reason it is recommended to store the sensors in  
original packaging including the sealed ESD bag at  
following conditions: Temperature shall be in the range of  
10°C – 50°C and humidity at 20 – 60%RH (sensors that  
are not stored in ESD bags). For sensors that have been  
removed from the original packaging we recommend to  
store them in ESD bags made of PE-HD13.  
tP  
TP  
TL  
tL  
TS (max)  
In manufacturing and transport the sensors shall be  
prevented of high concentration of chemical solvents and  
long exposure times. Out-gassing of glues, adhesive tapes  
and stickers or out-gassing packaging material such as  
bubble foils, foams, etc. shall be avoided. Manufacturing  
area shall be well ventilated.  
preheating  
critical zone  
Time  
Figure 7 Soldering profile according to JEDEC standard. TP <=  
260°C and tP < 40sec for Pb-free assembly. TL < 220°C and tL <  
150sec. Ramp-up/down speeds shall be < 5°C/sec.  
For more detailed information please consult the  
document “Handling Instructions” or contact Sensirion.  
It is important to note that the diced edge or side faces of  
the I/O pads may oxidise over time, therefore a solder fillet  
may or may not form. Hence there is no guarantee for  
solder joint fillet heights of any kind.  
2.3 Reconditioning Procedure  
As stated above extreme conditions or exposure to solvent  
vapors may offset the sensor. The following reconditioning  
procedure may bring the sensor back to calibration state:  
For soldering SHT2x, standard reflow soldering ovens may  
be used. The sensor is qualified to withstand soldering  
profile according to IPC/JEDEC J-STD-020D with peak  
temperatures at 260°C during up to 40sec for Pb-free  
assembly in IR/Convection reflow ovens (see Figure 7).  
Baking:  
100 – 105°C at < 5%RH for 10h  
Re-Hydration: 20 – 30°C at ~ 75%RH for 12h 14.  
2.4 Temperature Effects  
Relative humidity reading strongly depends on  
temperature. Therefore, it is essential to keep humidity  
sensors at the same temperature as the air of which the  
relative humidity is to be measured. In case of testing or  
qualification the reference sensor and test sensor must  
show equal temperature to allow for comparing humidity  
readings.  
For manual soldering contact time must be limited to 5  
seconds at up to 350°C12.  
IMPORTANT: After soldering, the devices should be  
stored at >75%RH for at least 12h to allow the sensor  
element to re-hydrate. Otherwise the sensor may read an  
offset that slowly disappears if exposed to ambient  
conditions. Alternatively the re-hydration process may be  
performed at ambient conditions (>40%RH) during more  
than 5 days.  
If the sensor shares a PCB with electronic components  
that produce heat it should be mounted in a way that  
prevents heat transfer or keeps it as low as possible.  
Measures to reduce heat transfer can be ventilation,  
reduction of copper layers between the sensor and the  
rest of the PCB or milling a slit into the PCB around the  
sensor – see Figure 8.  
In no case, neither after manual nor reflow soldering, a  
board wash shall be applied. Therefore, and as mentioned  
above, it is strongly recommended to use “no-clean” solder  
paste. In case of applications with exposure of the sensor  
to corrosive gases the soldering pads shall be sealed to  
prevent loose contacts or short cuts.  
Furthermore, there are self-heating effects in case the  
measurement frequency is too high. To keep self heating  
below 0.1°C, SHT2x should not be active for more than  
10% of the time – e.g. maximum two measurements per  
second at 12bit accuracy shall be made.  
2.2 Storage Conditions and Handling Instructions  
Moisture Sensitivity Level (MSL) is 2; hence storage time  
is limited to one year.  
11  
13  
Solder types are related to the solder particle size in the paste: Type 3 covers  
For example, 3M antistatic bag, product “1910” with zipper.  
14  
the size range of 25 – 45 µm (powder type 42).  
75%RH can conveniently be generated with saturated NaCl solution.  
100 – 105°C correspond to 212 – 221°F, 20 – 30°C correspond to 68 – 86°F  
12  
260°C = 500°F, 350°C = 662°F  
www.sensirion.com  
Version 1.0 – January 2010  
4/12  
Datasheet SHT21  
3 Interface Specifications  
Pin Name  
Comment  
2
1
6
5
VSS Ground  
4
5
6
3
2
1
SDA Serial Data, bidirectional  
SCL Serial Clock, bidirectional  
VDD Supply Voltage  
3,4 NC Not Connected, floating  
Figure 8 Top view of example of mounted SHT2x with slits  
milled into PCB to minimize heat transfer.  
Table 2 SHT2x pin assignment, NC remain floating  
2.5 Light  
3.1 Power Pins (VDD, VSS)  
The SHT2x is not light sensitive. Prolonged direct  
exposure to sunshine or strong UV radiation may age the  
sensor.  
The supply voltage of SHT2x must be in the range of 2.1 –  
3.6V, recommended supply voltage is 3.0V. Power supply  
pins Supply Voltage (VDD) and Ground (VSS) must be  
decoupled with a 100nF capacitor, that shall be placed as  
close to the sensor as possible – see Figure 9.  
2.6 Materials Used for Sealing / Mounting  
Many materials absorb humidity and will act as a buffer  
increasing response times and hysteresis. Materials in the  
vicinity of the sensor must therefore be carefully chosen.  
Recommended materials are: Any metals, LCP, POM  
(Delrin), PTFE (Teflon), PEEK, PP, PB, PPS, PSU, PVDF,  
PVF.  
3.2 Serial clock (SCL)  
SCL is used to synchronize the communication between  
microcontroller (MCU) and the sensor. Since the interface  
consists of fully static logic there is no minimum SCL  
frequency.  
For sealing and gluing (use sparingly): Use high filled  
epoxy for electronic packaging (e.g. glob top, underfill),  
and Silicone. Out-gassing of these materials may also  
contaminate the sensor (see Section 1.3). Therefore try to  
add the sensor as a last manufacturing step to the  
assembly, store the assembly well ventilated after  
manufacturing or bake at >50°C for 24h to outgas  
contaminants before packing.  
3.3 Serial SDA (SDA)  
The SDA pin is used to transfer data in and out of the  
sensor. For sending a command to the sensor, SDA is  
valid on the rising edge of SCL and must remain stable  
while SCL is high. After the falling edge of SCL the SDA  
value may be changed. For safe communication SDA shall  
be valid tSU and tHD before the rising and after the falling  
edge of SCL, respectively – see Figure 10. For reading  
data from the sensor, SDA is valid tVD after SCL has gone  
low and remains valid until the next falling edge of SCL.  
2.7 Wiring Considerations and Signal Integrity  
Carrying the SCL and SDA signal parallel and in close  
proximity (e.g. in wires) for more than 10cm may result in  
cross talk and loss of communication. This may be  
resolved by routing VDD and/or VSS between the two  
SDA signals and/or using shielded cables. Furthermore,  
slowing down SCL frequency will possibly improve signal  
integrity. Power supply pins (VDD, VSS) must be  
decoupled with a 100nF capacitor – see next Section.  
VDD  
MCU (master)  
RP RP  
SCL IN  
SCL  
SCL OUT  
SHT2x  
(slave)  
SDA IN  
SDA  
GND  
SDA OUT  
Figure 9 Typical application circuit, including pull-up resistors  
RP and decoupling of VDD and VSS by a capacitor.  
To avoid signal contention the micro-controller unit (MCU)  
must only drive SDA and SCL low. External pull-up  
resistors (e.g. 10kΩ), are required to pull the signal high.  
For the choice of resistor size please take bus capacity  
requirements into account (compare Table 5). It should be  
noted that pull-up resistors may be included in I/O circuits  
www.sensirion.com  
Version 1.0 – January 2010  
5/12  
Datasheet SHT21  
1/fSCK  
of MCUs. See Table 4 and Table 5 for detailed I/O  
characteristic of the sensor.  
tSCKH  
tR  
tF  
tSCKL  
70%  
30%  
SCL  
4 Electrical Characteristics  
4.1 Absolute Maximum Ratings  
SDA valid write  
tSU  
tHD  
DATA IN  
The electrical characteristics of SHT2x are defined in  
Table 1. The absolute maximum ratings as given in Table  
3 are stress ratings only and give additional information.  
Functional operation of the device at these conditions is  
not implied. Exposure to absolute maximum rating  
conditions for extended periods may affect the sensor  
reliability (e.g. hot carrier degradation, oxide breakdown).  
70%  
30%  
SDA  
SDA valid read  
tVD  
tR  
tF  
DATA OUT  
70%  
30%  
SDA  
Figure 10 Timing Diagram for Digital Input/Output Pads,  
abbreviations are explained in Table 5. SDA directions are seen  
from the sensor. Bold SDA line is controlled by the sensor, plain  
SDA line is controlled by the micro-controller. Both valid times  
(SDA read and SDA write) refer to the left SCL toggle.  
Parameter  
min  
-0.3  
max  
5
Units  
V
VDD to VSS  
Digital IO Pins (SDA, SCL)  
to VSS  
-0.3  
VDD + 0.3  
100  
V
Input Current on any Pin  
-100  
mA  
Parameter  
min typ max Units  
Table 3 Electrical absolute maximum ratings  
SCL frequency, fSCL  
SCL High Time, tSCLH  
SCL Low Time, tSCLL  
SDA Set-Up Time, tSU  
SDA Hold Time, tHD  
SDA Valid Time, tVD  
SCL/SDA Fall Time, tF  
SCL/SDA Rise Time, tR  
Capacitive Load on Bus Line, CB  
0
0.6  
1.3  
100  
0
-
-
-
-
-
-
-
-
-
0.4 MHz  
-
µs  
µs  
ns  
ns  
ns  
ns  
ns  
pF  
ESD immunity is qualified according to MIL STD 883E,  
method 3015 (Human Body Model at 2 kV). Latch-up  
immunity is provided at a force current of 100mA with  
Tamb = 80°C according to JEDEC78A. For exposure  
beyond named limits the sensor needs additional  
protection circuit.  
-
-
900  
400  
100  
300  
400  
0
0
0
4.2 Input / Output Characteristics  
0
The electrical characteristics such as power consumption,  
low and high level input and output voltages depend on  
the supply voltage. For proper communication with the  
sensor it is essential to make sure that signal design is  
strictly within the limits given in Table 4 & 5 and Figure 10.  
Table 5 Timing specifications of digital input/output pads for I2C  
fast mode. Entities are displayed in Figure 10. VDD = 2.1V to  
3.6V, T = -40°C to 125°C, unless otherwise noted.  
5 Communication with Sensor  
Parameter  
Conditions  
min typ max Units  
SHT21 communicates with true I2C protocol. For  
information on I2C beyond the information in the following  
Sections please refer to the following website:  
Output Low  
Voltage, VOL  
VDD = 3.0 V,  
-4 mA < IOL < 0mA  
0
-
-
-
-
-
-
0.4  
VDD  
-4  
V
V
Output High  
Voltage, VOH  
70%  
VDD  
http://www.standardics.nxp.com/support/i2c/.  
Please note that all sensors are set to the same I2C  
Output Sink  
Current, IOL  
address, as defined in Section 5.3. 15  
-
mA  
V
Input Low  
Voltage, VIL  
30%  
VDD  
Furthermore, please note, that Sensirion provides a  
sample code on its home page  
www.sensirion.com/sht21.  
0
compare  
Input High  
Voltage, VIH  
70%  
VDD  
VDD  
±1  
V
5.1 Start Up Sensor  
VDD = 3.6 V,  
VIN = 0 V to 3.6 V  
Input Current  
-
uA  
As a first step, the sensor is powered up to the chosen  
supply voltage VDD (between 2.1 V and 3.6 V). After  
power-up, the sensor needs at most 15 ms, while SCL is  
high, for reaching idle state, i.e. to be ready accepting  
Table 4 DC characteristics of digital input/output pads. VDD =  
2.1 V to 3.6 V, T = -40 °C to 125 °C, unless otherwise noted.  
15  
For sensors with alternative I2C address please contact Sensirion via  
info@sensirion.com.  
www.sensirion.com  
Version 1.0 – January 2010  
6/12  
Datasheet SHT21  
commands from the master (MCU). Current consumption  
5.4 Hold / No Hold Master Mode  
during start up is 350µA maximum.  
There are two different operation modes to communicate  
with the sensor: Hold Master mode or No Hold Master  
mode. In the first case the SCL line is blocked (controlled  
by sensor) during measurement process while in the latter  
case the SCL line remains open for other communication  
while the sensor is processing the measurement. No hold  
master mode allows for processing other I2C  
communication tasks on a bus while the sensor is  
measuring. A communication sequence of the two modes  
is displayed in Figure 13 and Figure 14, respectively.  
5.2 Start / Stop Sequence  
Each transmission sequence begins with Start condition  
(S) and ends with Stop condition (P) as displayed in Figure  
11 and Figure 12.  
70%  
SCL  
30%  
70%  
In the hold master mode, the SHT2x pulls down the SCL  
line while measuring to force the master into a wait state.  
By releasing the SCL line the sensor indicates that internal  
processing is terminated and that transmission may be  
continued.  
SDA  
30%  
Figure 11 Transmission Start Condition (S) - a high to low  
transition on the SDA line while SCL is high. The Start condition  
is a unique state on the bus created by the master, indicating to  
the slaves the beginning of a transmission sequence (bus is  
considered busy after a Start).  
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18  
S 1 0 0 0 0 0 0 0  
1 1 1 0 0 1 0 1  
70%  
I2C address + write  
Command (see Table 6)  
SCL  
30%  
19 20 21 22 23 24 25 26 27  
S 1 0 0 0 0 0 0 1  
Measurement  
70%  
I2C address + read  
Hold during measurement  
SDA  
30%  
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45  
Figure 12 Transmission Stop Condition (P) - a low to high  
transition on the SDA line while SCL is high. The Stop condition  
is a unique state on the bus created by the master, indicating to  
the slaves the end of a transmission sequence (bus is  
considered free after a Stop).  
0 1 1 0 0 0 1 1  
Data (MSB)  
0 1 0 1 0 0 1 0  
Data (LSB) Stat.  
46 47 48 49 50 51 52 53 54  
0 1 1 0 0 0 1 1  
P
5.3 Sending a Command  
Checksum  
After sending the Start condition, the subsequent I2C  
header consists of the 7-bit I2C device address ‘1000’000’  
and an SDA direction bit (Read R: ‘1’, Write W: ‘0’). The  
sensor indicates the proper reception of a byte by pulling  
the SDA pin low (ACK bit) after the falling edge of the 8th  
SCL clock. After the issue of a measurement command  
(‘1110’0011’ for temperature, ‘1110’0101’ for relative  
humidity’), the MCU must wait for the measurement to  
complete. The basic commands are summarized in Table  
6. Hold master or no hold master modes are explained in  
next Section.  
Figure 13 Hold master communication sequence – grey blocks  
are controlled by SHT2x. Bit 45 may be changed to NACK  
followed by Stop condition (P) to omit checksum transmission.  
In no hold master mode, the MCU has to poll for the  
termination of the internal processing of the sensor. This is  
done by sending a Start condition followed by the I2C  
header (1000’0001) as shown in Figure 14. If the internal  
processing is finished, the sensor acknowledges the poll of  
the MCU and data can be read by the MCU. If the  
measurement processing is not finished the sensor  
answers no ACK bit and the Start condition must be  
issued once more.  
Command  
Comment  
Code  
Trigger T measurement  
Trigger RH measurement  
Trigger T measurement  
Trigger RH measurement  
Write user register  
Read user register  
Soft reset  
hold master  
hold master  
1110’0011  
1110’0101  
For both modes, since the maximum resolution of a  
measurement is 14 bit, the two last LSBs (bits 43 and 44)  
are used for transmitting status information. Bit 1 of the  
two LSBs indicates the measurement type (‘0’:  
temperature, ‘1’ humidity). Bit 0 is currently not assigned.  
no hold master 1111’0011  
no hold master 1111’0101  
1110’0110  
1110’0111  
1111’1110  
Table 6 Basic command set, RH stands for relative humidity,  
and T stands for temperature  
www.sensirion.com  
Version 1.0 – January 2010  
7/12  
Datasheet SHT21  
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18  
5.5 Soft Reset  
S 1 0 0 0 0 0 0 0  
1 1 1 1 0 1 0 1  
Command (see Table 6)  
This command (see Table 6) is used for rebooting the  
sensor system without switching the power off and on  
again. Upon reception of this command, the sensor  
system reinitializes and starts operation according to the  
default settings. The soft reset takes less than 15 ms.  
I2C address + write  
19 20 21 22 23 24 25 26 27  
Measurement  
S 1 0 0 0 0 0 0 1  
I2C address + read  
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18  
1 1 1 1 1 1 1 0  
Soft Reset  
measuring  
S 1 0 0 0 0 0 0 0  
P
19 20 21 22 23 24 25 26 27  
I2C address + write  
Measurement  
S 1 0 0 0 0 0 0 1  
I2C address + read  
Figure 15 Soft Reset – grey blocks are controlled by SHT2x.  
continue measuring  
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45  
5.6 User Register  
0 1 1 0 0 0 1 1  
Data (MSB)  
0 1 0 1 0 0 1 0  
The content of user register is described in Table 8.  
Please note that reserved bits must not be changed.  
Data (LSB) Stat.  
46 47 48 49 50 51 52 53 54  
Bit  
# Bits  
2
Description / Coding  
Default  
‘00’  
0 1 1 0 0 0 1 1  
P
7, 0  
Measurement resolution  
Checksum  
RH  
T
‘00’  
‘01’  
‘10’  
‘11’  
12 bit  
8 bit  
10 bit  
11 bit  
14 bit  
12 bit  
13 bit  
11 bit  
Figure 14 No Hold master communication sequence – grey  
blocks are controlled by SHT2x. If measurement is not  
completed upon “read” command, sensor does not provide ACK  
on bit 27 (more of these iterations are possible). If bit 45 is  
changed to NACK followed by Stop condition (P) checksum  
transmission is omitted.  
6
1
Status: End of battery16  
‘0’: VDD > 2.25 V  
‘0’  
‘1’: VDD < 2.25 V  
In the examples given in Figure 13 and Figure 14 the  
sensor output is SRH = ‘0110’0011’0101’0000’. For the  
calculation of physical values Status Bits must be set to ‘0’  
– see Chapter 6.  
3, 4, 5  
3
1
1
Reserved  
2
1
Enable on-chip heater  
Disable OTP reload  
‘0’  
‘1’  
The maximum duration for measurements depends on the  
type of measurement and resolution chosen – values are  
displayed in Table 7. Maximum values shall be chosen for  
the communication planning of the MCU.  
Table 8 User Register. Cut-off value for End of Battery signal  
may vary by ±0.05V. Reserved bits must not be changed. “OTP  
reload” = ‘0’ loads default settings after each time a  
measurement command is issued.  
The End of Battery alert is activated when the battery  
power falls below 2.25V.  
Resolution RH typ RH max T typ  
T max  
85  
Units  
ms  
14 bit  
13 bit  
12 Bit  
11 bit  
10 bit  
8 bit  
66  
33  
17  
9
The heater is intended to be used for functionality  
43  
ms  
diagnosis  
– relative humidity drops upon rising  
22  
12  
7
29  
15  
9
22  
ms  
temperature. The heater consumes about 5.5mW and  
provides a temperature increase of about 0.5 – 1.5°C.  
11  
ms  
ms  
OTP Reload is a safety feature and loads the entire OTP  
settings to the register before every measurement. This  
feature is disabled per default and is not recommended for  
use. Please use Soft Reset instead – it contains OTP  
Reload.  
3
4
ms  
Table 7 Measurement times for RH and T measurements at  
different resolutions. Typical values are recommended for  
calculating energy consumption while maximum values shall be  
applied for calculating waiting times in communication.  
An example for I2C communication reading and writing the  
User Register is given in Figure 16. It is important that first  
the content of the register is read in order getting the  
default values. Hereafter, the resolution is changed by  
configuring register. Please note that the reserved user-  
register bits must not be changed.  
Please note: I2C communication allows for repeated Start  
conditions (S) without closing prior sequence with Stop  
condition (P) – compare Figures 13, 14 and 16. Still, any  
sequence with adjacent Start condition may alternatively  
be closed with a Stop condition.  
16 This status bit is updated after each measurement  
www.sensirion.com  
Version 1.0 – January 2010  
8/12  
Datasheet SHT21  
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18  
Meteorological Organization (WMO). For relative humidity  
above ice RHi the values need to be transformed from  
relative humidity above water RHw at temperature t. The  
equation is given in the following, compare also  
Application Note “Introduction to Humidity:  
S 1 0 0 0 0 0 0 0  
1 1 1 0 0 1 1 1  
I2C address + write  
Read Register  
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36  
S 1 0 0 0 0 0 0 1  
0 0 0 0 0 0 1 0  
βw t  
λw t  
βi t  
λi t  
exp  
RHi RHw exp  
I2C address + read  
Register content  
37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54  
Units are %RH for relative humidity and °C for  
temperature. The corresponding coefficients are defined  
as follows: βw = 17.62, λw = 243.12°C, βi = 22.46, λi =  
272.62°C.  
S 1 0 0 0 0 0 0 0  
I2C address + write  
1 1 1 0 0 1 1 0  
Write Register  
55 56 57 58 59 60 61 62 63  
0 0 0 0 0 0 1 1  
P
6.2 Temperature Conversion  
Register content to be written  
The temperature T is calculated by inserting temperature  
signal output ST into the following formula (result in °C), no  
matter which resolution is chosen:  
Figure 16 Read and write register sequence – grey blocks are  
controlled by SHT2x. In this example, the resolution is set to 8bit  
/ 12bit.  
ST  
T   46.85 175.72   
216  
5.7 CRC Checksum  
For implementing CRC8 checksum please refer to  
Wikipedia (http://en.wikipedia.org/wiki/crc8).  
7 Environmental Stability  
5.8 Serial Number  
The SHT2x sensor series were tested according to AEC-  
Q100 Rev.  
F qualification test method. Sensor  
SHT21 provides an electronic identification code. For  
instructions on how to read the identification code please  
refer to the Application Note “Electronic Identification  
Code” – to be downloaded from the web page  
www.sensirion.com/SHT21.  
specifications are tested to prevail under the AEC-Q100  
temperature grade 2 test conditions listed in Table 917.  
Sensor performance under other test conditions cannot be  
guaranteed and is not part of the sensor specifications.  
Especially, no guarantee can be given for sensor  
performance in the field or for customer’s specific  
application.  
6 Conversion of Signal Output  
Environment Standard  
Results18  
Default resolution is set to 12 bit relative humidity and 14  
bit temperature reading. Measured data are transferred in  
two byte packages, i.e. in frames of 8 bit length where the  
most significant bit (MSB) is transferred first (left aligned).  
Each byte is followed by an acknowledge bit. The two  
status bits, the last bits of LSB, must be set to ‘0’ before  
calculating physical values. In the example of Figure 13  
and Figure 14, the transferred 16 bit relative humidity data  
is ‘0110’0011’0101’0000’ = 25424.  
HTSL  
125°C, 1000 hours  
Within  
specifications  
TC  
-50°C - 125°C, 1000 cycles  
Acc. JESD22-A104-C  
Within  
specifications  
UHST  
THU  
130°C / 85%RH, 96h  
Within  
specifications  
85°C / 85%RH, 1000h  
Within  
specifications  
ESD immunity MIL STD 883E, method 3015 Qualified  
(Human Body Model at ±2kV)  
6.1 Relative Humidity Conversion  
With the relative humidity signal output SRH the relative  
humidity RH is obtained by the following formula (result in  
%RH), no matter which resolution is chosen:  
Latch-up  
force current of ±100mA with Qualified  
Tamb = 80°C, acc. JEDEC 17  
Table 9: Qualification tests: HTSL = High Temperature Storage  
Lifetime, TC = Temperature Cycles, UHST = Unbiased Highly  
SRH  
216  
RH 6 125   
accelerated Stress Test, THU  
Unbiased.  
= Temperature Humidity  
In the example given in Figure 13 and Figure 14 the  
relative humidity results to be 42.5%RH.  
17  
Sensor operation temperature range is -40 to 105°C according to AEC-Q100  
temperature grade 2.  
The physical value RH given above corresponds to the  
relative humidity above liquid water according to World  
18  
According to accuracy and long term drift specification given on Page 2.  
www.sensirion.com  
Version 1.0 – January 2010  
9/12  
Datasheet SHT21  
If sensors are qualified for reliability and behavior in  
extreme conditions, please make sure that they  
experience same conditions as the reference sensor. It  
should be taken into account that response times in  
assemblies may be longer, hence enough dwell time for  
the measurement shall be granted. For detailed  
information please consult Application Note “Qualification  
Guide”.  
Lot No.:  
Quantity:  
RoHS:  
XXO-NN-YRRRRTTTT  
RRRR  
Compliant  
Lot No.  
Figure 18: First label on reel: XX = Sensor Type (21 for SHT21),  
O = Output mode (D = Digital, P = PWM, S = SDM), NN = Chip  
Version, Y = last digit of year, RRRR = number of sensors on  
reel, TTTT = Traceability Code.  
8 Packaging  
8.1 Packaging Type  
SHT2x sensors are provided in DFN packaging (in  
analogy with QFN packaging). DFN stands for Dual Flat  
No leads.  
The sensor chip is mounted to a lead frame made of Cu  
and plated with Ni/Pd/Au. Chip and lead frame are over  
molded by green epoxy-based mold compound. Please  
note that side walls of sensors are diced and hence lead  
frame at diced edge is not covered with respective  
protective coating. The total weight of the sensor is 25mg.  
Device Type:  
Description:  
1-100PPP-NN  
Humidity & Temperature Sensor  
SHTxx  
Part Order No. 1-100PPP-NN or Customer Number  
Date of Delivery: DD.MM.YYYY  
Order Code:  
45CCCC / 0  
8.2 Filter Cap and Sockets  
For SHT2x a filter cap SF2 will be provided. It is designed  
for fast response times and compact size. Please find the  
datasheet on Sensirion’s web page by February 2010.  
Figure 19: Second label on reel: For Device Type and Part  
Order Number (See Packaging Information on page 2), Delivery  
Date (also Date Code) is date of packaging of sensors (DD =  
day, MM = month, YYYY = year), CCCC = Sensirion order  
number.  
For testing of SHT2x sensors sockets, such as from  
Plastronics, part number 10LQ50S13030  
recommended (see e.g. www.locknest.com).  
are  
8.4 Shipping Package  
SHT2x are provided in tape & reel shipment packaging,  
sealed into antistatic ESD bags. Standard packaging sizes  
are 400, 1500 and 5000 units per reel. For SHT21, each  
reel contains 440mm (55 pockets) header tape and  
200mm (25 pockets) trailer tape.  
8.3 Traceability Information  
All SHT2x are laser marked with an alphanumeric, five-  
digit code on the sensor – see Figure 17.  
The marking on the sensor consists of two lines with five  
digits each. The first line denotes the sensor type  
(SHT21). The first digit of the second line defines the  
output mode (D = digital, Sensibus and I2C, P = PWM, S =  
SDM). The second digit defines the manufacturing year (0  
= 2010, 1 = 2011, etc.). The last three digits represent an  
alphanumeric tracking code. That code can be decoded by  
Sensirion only and allows for tracking on batch level  
through production, calibration and testing – and will be  
provided upon justified request.  
The drawing of the packaging tapes with sensor  
orientation is shown in Figure 20. The reels are provided in  
sealed antistatic bags.  
8.0  
Ø0.15 MIN  
2.0  
4.0  
0.3  
Ø0.15 MIN  
R0.3 MAX  
1.3  
3.3  
0.25  
R0.25  
SHT21  
D0AC4  
Figure 20 Sketch of packaging tape and sensor orientation.  
Header tape is to the right and trailer tape to the left on this  
sketch.  
Figure 17 Laser marking on SHT21. For details see text.  
Reels are also labeled, as displayed in Figure 18 and  
Figure 19, and give additional traceability information.  
www.sensirion.com  
Version 1.0 – January 2010  
10/12  
Datasheet SHT21  
9 Compatibility to SHT1x / 7x protocol  
SHT2x sensors may be run by communicating with the  
Sensirion specific communication protocol used for SHT1x  
and SHT7x. In case such protocol is applied please refer  
to the communication chapter of datasheet SHT1x or  
SHT7x. Please note that reserved status bits of user  
register must not be changed.  
Please understand that with the SHT1x/7x communication  
protocol only functions described in respective datasheets  
can be used with the exception of the OTP reload function  
that is not set to default on SHT2x. As an alternative to  
OTP reload the soft reset may be used. Please note that  
even if SHT1x/7x protocol is applied the timing values of  
Table 5 and Table 7 as well as the calculation of physical  
values in this SHT2x datasheet apply.  
www.sensirion.com  
Version 1.0 – January 2010  
11/12  
Datasheet SHT21  
Revision History  
Date  
Version  
0.3  
Page(s) Changes  
6 May 2009  
7 Sept 2009  
21 January 2010  
1 – 9  
Initial preliminary release  
0.5  
1,3,6,8-9 Revise Section 1.2, Figs. 1, 5 and 9, Table 5. Add Chapter 7  
1.0  
1 – 4, 7 – Complete revision. For complete revision list please require respective document from  
10  
Sensirion.  
Important Notices  
Warning, Personal Injury  
Do not use this product as safety or emergency stop devices or in  
any other application where failure of the product could result in  
personal injury. Do not use this product for applications other  
than its intended and authorized use. Before installing, handling,  
using or servicing this product, please consult the data sheet and  
application notes. Failure to comply with these instructions could  
result in death or serious injury.  
such defects shall be found, to SENSIRION’s reasonable  
satisfaction, to have arisen from SENSIRION’s faulty design,  
material, or workmanship;  
the defective product shall be returned to SENSIRION’s factory at  
the Buyer’s expense; and  
the warranty period for any repaired or replaced product shall be  
limited to the unexpired portion of the original period.  
This warranty does not apply to any equipment which has not been  
installed and used within the specifications recommended by  
SENSIRION for the intended and proper use of the equipment.  
EXCEPT FOR THE WARRANTIES EXPRESSLY SET FORTH  
HEREIN, SENSIRION MAKES NO WARRANTIES, EITHER EXPRESS  
OR IMPLIED, WITH RESPECT TO THE PRODUCT. ANY AND ALL  
WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES  
If the Buyer shall purchase or use SENSIRION products for any  
unintended or unauthorized application, Buyer shall defend, indemnify  
and hold harmless SENSIRION and its officers, employees,  
subsidiaries, affiliates and distributors against all claims, costs,  
damages and expenses, and reasonable attorney fees arising out of,  
directly or indirectly, any claim of personal injury or death associated  
with such unintended or unauthorized use, even if SENSIRION shall be  
allegedly negligent with respect to the design or the manufacture of the  
product.  
OF MERCHANTABILITY OR FITNESS FOR  
A PARTICULAR  
PURPOSE, ARE EXPRESSLY EXCLUDED AND DECLINED.  
SENSIRION is only liable for defects of this product arising under the  
conditions of operation provided for in the data sheet and proper use of  
the goods. SENSIRION explicitly disclaims all warranties, express or  
implied, for any period during which the goods are operated or stored  
not in accordance with the technical specifications.  
SENSIRION does not assume any liability arising out of any application  
or use of any product or circuit and specifically disclaims any and all  
liability, including without limitation consequential or incidental  
damages. All operating parameters, including without limitation  
recommended parameters, must be validated for each customer’s  
applications by customer’s technical experts. Recommended  
parameters can and do vary in different applications.  
ESD Precautions  
The inherent design of this component causes it to be sensitive to  
electrostatic discharge (ESD). To prevent ESD-induced damage and/or  
degradation, take customary and statutory ESD precautions when  
handling this product.  
See application note “ESD, Latchup and EMC” for more information.  
Warranty  
SENSIRION warrants solely to the original purchaser of this product for  
a period of 12 months (one year) from the date of delivery that this  
product shall be of the quality, material and workmanship defined in  
SENSIRION’s published specifications of the product. Within such  
period, if proven to be defective, SENSIRION shall repair and/or  
replace this product, in SENSIRION’s discretion, free of charge to the  
Buyer, provided that:  
SENSIRION reserves the right, without further notice, (i) to change the  
product specifications and/or the information in this document and (ii) to  
improve reliability, functions and design of this product.  
Copyright © 2010, by SENSIRION.  
notice in writing describing the defects shall be given to  
SENSIRION within fourteen (14) days after their appearance;  
CMOSens® is a trademark of Sensirion  
All rights reserved  
Headquarter and Sales Offices  
Headquarter  
SENSIRION AG  
Laubisruetistr. 50  
CH-8712 Staefa ZH  
Switzerland  
Phone:  
Fax:  
info@sensirion.com  
+41 44 306 40 00  
+41 44 306 40 30  
Sales Office Korea:  
SENSIRION KOREA Co. Ltd.  
#1414, Anyang Construction Tower B/D, Fax:  
1112-1, Bisan-dong, Anyang-city  
Gyeonggi-Province  
Phone:  
+82 31 440 9925~27  
+82 31 440 9927  
http://www.sensirion.com/  
info@sensirion.co.kr  
http://www.sensirion.co.kr  
Sales Office USA:  
SENSIRION Inc.  
2801 Townsgate Rd., Suite 204  
Westlake Village, CA 91361  
USA  
South Korea  
Phone:  
Fax:  
+1 805 409 4900  
+1 805 435 0467  
Sales Office China:  
michael.karst@sensirion.com  
http://www.sensirion.com/  
Sensirion China Co. Ltd.  
Room 2411, Main Tower  
Jin Zhong Huan Business Building,  
Futian District, Shenzhen,  
Postal Code 518048  
phone:  
fax:  
info@sensirion.com.cn  
+86 755 8252 1501  
+86 755 8252 1580  
Sales Office Japan:  
www.sensirion.com.cn  
SENSIRION JAPAN Co. Ltd.  
Postal Code: 108-0074  
Shinagawa Station Bldg. 7F,  
4-23-5, Takanawa, Minato-ku  
Tokyo, Japan  
Phone:  
Fax:  
info@sensirion.co.jp  
+81 3 3444 4940  
+81 3 3444 4939  
PR China  
http://www.sensirion.co.jp  
Find your local representative at: http://www.sensirion.com/reps  
www.sensirion.com  
Version 1.0 – January 2010  
12/12  

相关型号:

SHT25

Humidity and Temperature Sensor
ETC

SHT50V221MD102

Surface Mount Aluminum Electrolytic Capacitors
MERITEK

SHT50V221ME102

Surface Mount Aluminum Electrolytic Capacitors
MERITEK

SHT50V221MF102

Surface Mount Aluminum Electrolytic Capacitors
MERITEK

SHT50V221MH102

Surface Mount Aluminum Electrolytic Capacitors
MERITEK

SHT50V221MJ102

Surface Mount Aluminum Electrolytic Capacitors
MERITEK

SHT6.3X32

Cartridge Fuse, 6.3x32 mm, 400-500 VAC, 400 VDC, 1-32 A, High Breaking Capacity up to 3500 A
SCHURTER

SHT6.3X32_18

Cartridge Fuse, 6.3x32 mm, 400-500 VAC, 400 VDC, 1-32 A, High Breaking Capacity up to 3500 A
SCHURTER

SHT71

Humidity & Temperature Sensor
ETC

SHT75

Humidity & Temperature Sensor
ETC

SHT7X

Humidity & Temperature Sensor
ETC

SHT842

Three phase Solid State Relay for printed circuit board
CELDUC