MR57T00101F [OKI]
P2ROM MultiMediaCard; P2ROM多媒体型号: | MR57T00101F |
厂家: | OKI ELECTRONIC COMPONETS |
描述: | P2ROM MultiMediaCard |
文件: | 总24页 (文件大小:150K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FEDR57T00101F-02-03
Issue Date: September 17, 2004
OKI Semiconductor
MR57T00101F
P2ROM MultiMediaCard
1. GENERAL DESCRIPTION
P2ROM MMC stands for P2ROM MultiMediaCard in which an Oki Original Product P2ROM is embedded.
P2ROM (Production Programmed ROM) utilizes Oki unique memory cell, which is an exclusive Oki technology.
Unlike MASKROM, no mask charges apply; Unlike OTP and Flash memory, no additional programming cost is
required.
ꢀ
Features
Compliant with MMCA standard (Version 3.1)
•
•
Card name/capacity
1MB P2ROM MMC: MR57T00101F-xxxKB
•
•
Operating voltage: 2.7V~3.6V
Outside dimension: 32(D)×24(W)×1.4(H)mm
ꢀ
ꢀ
Notice
This product is different from Secure MMC.
Applications
P2ROM MMC is applied to devices embedded with MultiMediaCard Slot, e.g. Mobile phone,
Electronic dictionary, Game machine, etc.
1/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
2. BLOCK DIAGRAM
1
2
3
4
5
6
7
GND
GND
VDD
Interface Driver
Register
OCR [31:0]
CID[127:0]
RCA [15:0]
CSD[127:0]
Card
Interface
Controller
Memory Controller
P2ROM
2/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
3. PIN DESCRIPTIONS
MMC Mode
SPI Mode
Pin No
1
Symbol
RSV
Type
NC
Function
Reserved
Symbol
CS
Type
Input
Function
Chip select
(50K Pull-up)
Data in
2
CMD
Input/
Output
S
Command/Response
(Output: 8mA)
Supply voltage ground
Supply voltage
Clock
DI
Input
3
4
5
6
7
VSS
VDD
CLK
VSS
DAT
VSS
VDD
SCLK
VSS
DO
S
S
Supply voltage ground
Supply voltage
Clock
S
Input
S
Input
S
Supply voltage ground
Data
(Output: 8mA)
Supply voltage ground
Data out
(Output: 8mA)
Input/
Output
Output
Note: No. 6 pin is used to supply Vpp when writing data into P2ROM. It should be connected to GND for general
use.
3/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
4. COMMAND
4.1 Command Format (MMC Mode/SPI Mode)
Bit position
Bit width
Value
47
1
46
1
[45:40]
[39:08]
[07:01]
00
1
6
x
32
x
7
x
“0”
“1”
“1”
Description
Start bit
Transmission bit Command index
Argument
CRC7
End bit
4.2 Command Class (MMC Mode)
0
+
1
+
2
+
3
+
4
+
7
+
9
+
10 11 12 13 15 16 17 18 20 23
Class 0
Class 1
Basic
+
+
+
+
Stream
read
+
Block
read
Class 2
+
+
+
+
4.3 Command Class (SPI Mode)
0
1
+
9
+
10
12
13
+
16
+
17
+
18
23
58
+
59
+
Class 0
Class 1
Class 2
Basic
+
+
Non support
Block read
+
+
+
4/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
4.4 Command -1/3
MMC mode
SPI mode
CMD
0
Abbreviation
Command Description
Type Argument Resp Argument Resp
GO_IDLE_STATE
Resets all cards to Idle
state.
bc
[31:00]
stuff bits
-
None
R1
When CS signal is set in
Low state, the card transits
to SPI mode after receiving
this command.
1
SEND_OP_COND
Asks the card to send an R3
response including OCR
data. The operation voltage
span of the card can be got
according to OCR data.
Moreover, the highest-order
1 bit of OCR is used to
check whether the internal
processing of the card is
finished or not (Ready /Busy
polling).
bcr
[31:00]
OCR
without
busy
R3
None
R1
2
ALL_SEND_CID
Asks the cards in Ready
state to send their CID
numbers.
bcr
[31:00]
stuff bits
R2
-
-
The numbers are sent to
CMD signal when the card
is in MMC mode. When
every 1 bit is transferred,
the CMD signal state is
compared with the state
within the card. If different,
data transmission stops,
and the card returns to
Ready state. If matched, the
card recognizes itself
selected and transits to
Identification state.
3
SET_RELATIVE_ADDR Assigns Relative Card
Address (RCA) to the card
in Identification state.
ac
[31:16]
RCA
[15:00]
stuff bits
R1
-
-
When RCA is assigned, the
card transits to Stand-by
state, and does not
respond to following CMD2
& CMD3.
5/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
4.5 Command-2/3
MMC mode
SPI mode
CMD
4
Abbreviation
Command Description
Type Argument Resp Argument Resp
NOP (SET_DSR)
This command is for setting
DSR (Drive State Register).
But this card does not
support DSR.
bc
[31:16]
DSR
[15:00]
stuff bits
[31:16]
RCA
-
-
-
7
SELECT/
DESELECT_CARD
Selects a card and toggles
it between the Stand-by and
Transfer states.
ac
R1
-
-
[15:00]
stuff bits
When given an assigned
RCA, the card transits from
Stand-by state to Transfer
state, and responds to the
following read and other
commands. When given an
unassigned RCA, the card
transits to Stand-by state.
When RCA=0000h, the
card transits to Stand-by
state unconditionally.
9
SEND_CSD
SEND_CID
Asks the card to send its
CSD data.
ac
ac
[31:16]
RCA
[15:00]
stuff bits
[31:16]
RCA
R2
R2
R1
None
None
-
R1
R1
-
10
11
Asks the card to send its
CID data.
[15:00]
stuff bits
READ_DAT_UNTIL_STOP Asks the card to transfer adtc [31:00]
P2ROM data from the given
address, until interrupted by
CMD12.
data
address
6/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
4.4 Command-3/3
MMC mode
SPI mode
Resp
CMD
12
Abbreviation
Command Description
Type Argument Resp Argument
STOP
_TRANSMISSION
Forces the card to stop
processing of CMD11 and
CMD18.
ac
ac
[31:00]
stuff bits
R1
R1
None
R1
13
15
SEND_STATUS
Asks the card to send the
information of its status
register.
[31:16]
RCA
[15:00]
stuff bits
None
R2
GO_INACTIVE
_STATE
Sets the card to inactive
state.
ac
ac
[31:16]
RCA
[15:00]
stuff bits
[31:00]
block
-
-
-
16
17
SET_BLOCKLEN
Sets the block length for
following CMD17& CMD18.
R1
R1
[31:00]
block
length
[31:00]
data
R1
R1
length
READ_SINGLE
_BLOCK
Asks the card to transfer a
data block from the address
assigned by argument. (The
block length is set by
CMD16).
adtc [31:00]
data
address
address
18
23
READ_MULTIPLE
_BLOCK
Asks the card to transfer data adtc [31:00]
R1
R1
[31:00]
data
address
R1
R1
blocks continuously from the
address assigned by
data
address
argument until interrupted by
CMD12. (The block length is
set by CMD16)
SET_BLOCK_COUNT
Sets number of blocks to be
transferred for immediately
following CMD18.
ac
[31:16]
set to
[15:00]
[31:16]
set to 0
[15:00]
number of
block
0
number of
block
-
58
59
READ_OCR
Asks the card to transfer OCR
data.
-
-
-
-
None
R3
R1
CRC_ON_OFF
Makes CRC option to be ON
/OFF. The default in SPI
mode is CRC OFF.
[CRC option bit = 1] means
CRC ON;
-
[31:01]
stuff bits
[00:00]
CRC
option
[CRC option bit = 0] means
CRC OFF.
7/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
5. RESPONSES (MMC MODE)
5.1 R1 response
Object commands
CMD3: SET_RELATIVE_ADDR
CMD11: READ_DAT_UNTIL_STOP
CMD12: STOP_TRANSMISSION
CMD13: SEND_STATUS
CMD16: SET_BLOCKLEN
CMD17: READ_SINGLE_BLOCK
CMD18: READ_MULTIPLE_BLOCK
CMD23: SET_BLOCK_COUNT
Bit position
Bit width
Value
47
1
46
1
[45:40]
[39:08]
[07:01]
0
1
6
x
32
x
7
x
“0”
“0”
“1”
Description
Start bit
Transmission bit Command index
Card status
CRC7
End bit
5.2 R2 response
Object commands
CMD2: ALL_SEND_CID
CMD9: SEND_CSD
CMD10: SEND_CID
Bit position
135
1
134
[133:128]
6
[127:1]
0
1
Bit width
Value
1
“0”
127
x
“0”
“111111”
Reserved
“1”
Description
Start bit
Transmission bit
CID or CSD register
Internal CRC
End bit
5.3 R3 response
Object commands
CMD1: SEND_OP_COND
Bit position
47
1
46
[45:40]
6
[39:08]
[07:01]
7
0
1
Bit width
Value
1
“0”
32
“0”
“111111”
Reserved
x
“1111111”
Reserve
“1”
Description
Start bit
Transmission bit
OCR register
End bit
8/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
5.4 Card Status (MMC Mode)
Bit
31
Identifier
type
ER
Value
“0”= no error
“1”= error
Description
CC
C
out_of_range
The command’s argument was out of the
allowed range for this card.
30
29
address_error
ERX “0”= no error
“1”= error
A misaligned address which did not match the
block length was used in the command.
The transferred block length is not allowed for
this card, or the number of transferred bytes
does not match the block length.
Don’t care.
C
C
block_len_error
ER
“0”= no error
“1”= error
[28:24]
23
-
-
x
-
com_CRC_error
illegal_command
-
ER
ER
-
“0”= no error
“1”= error
“0”= no error
“1”= error
x
The CRC check in the immediately previous
command failed.
B
B
-
22
Command is not legal for the card state.
[21:13]
[12:09]
Don’t care.
current_state
SX
“0000”= idle
“0001”= ready
“0010”= ident
“0011”- stby
“0100”= tran
“0101”= data
Others: reserve
x
Current state of the card.
B
[08:00]
-
-
Don’t care.
-
5.5 Card status field / command – cross reference (MMC Mode)
Response Format 1 Status bit #
CMD
31
30
29
23
x
22
x
12:9
3
x
x
x
x
x
x
x
x
x
7
x
x
11
12
13
16
17
18
23
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
9/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
5.6 Card State Transition Table (MMC Mode)
current state
idle
ready ident stby tran data
changes to
ina
command
class independent
CRC error
-
-
-
-
-
-
-
-
-
-
-
-
-
-
command not supported
class 0
CMD0
idle
idle
idle
idle
idle
idle
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CMD1, card VDD range compatible
ready
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CMD1, card is busy
idle
-
-
-
CMD1, card VDD range not compatuble
ina
-
-
-
CMD2, card wins bus
-
-
-
-
-
-
-
-
-
-
-
ident
-
-
-
CMD2, card loses bus
ready
-
CMD3
-
-
-
-
-
-
-
-
-
stby
-
CMD4
-
-
-
-
-
-
-
-
stby
tran
-
CMD7, card is addressed
CMD7, card is not addressed
CMD9
stby stby
stby
stby
-
-
-
-
-
-
CMD10
CMD12
tran
CMD13
stby tran data
CMD15
ina
-
ina
ina
-
class 1
CMD11
-
-
-
data
-
class 2
CMD16
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
tran
data
data
tran
-
-
-
-
-
-
-
-
CMD17
CMD18
CMD23
10/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
6. RESPONSES (SPI MODE)
6.1 R1 response
Object commands
CMD0: GO_IDLE_STATE
CMD1: SEND_OP_COND
CMD9: SEND_CSD
CMD10: SEND_CID
CMD12: STOP_TRANSMISSION
CMD16: SET_BLOCKLEN
CMD17: READ_SINGLE_BLOCK
CMD18: READ_MULTIPLE_BLOCK
CMD23: SET_BLOCK_COUNT
CMD59: CRC_ON_OFF
7
0
6
5
4
3
2
1
0
0
0
in Idle state
illegal command
communication CRC error
address error
parameter error
6.2 R2 response
Object commands
CMD13: SEND_STATUS
15
14
13
12
11
10
9
8
7
6
0
5
0
4
3
0
2
0
1
0
0
0
0
0
0
0
Out of Range
in Idle state
illegal command
communication CRC error
address error
parameter error
6.3 R3 response
Object commands
CMD58: READ_OCR
39
38
37
36
35
34
33
0
32
31
0
0
0
OCR
in Idle state
illegal command
communication CRC error
address error
parameter error
11/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
6.4 Data Tokens (SPI Mode)
Data tokens are 4 to (N+3) bytes long (Where N is the data block length set by SET_BLOCK_LENGTH
Command) and have the following format:
Bit Position
Token Type
Transaction Type
7
1
1
6
1
1
5
1
1
4
1
1
3
1
1
2
1
1
1
1
1
0
0
0
Start Block
Start Block
Single Block Read
Multiple Block Read
6.5 Data Error Token
If a read operation fails or the given data is not accepted, following Data Error Token is sent:
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
Out of Range
Data Response
Token Type
(1byte)
Data
(512Bytes)
CRC
(2bytes)
12/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
6.6 Card Status (SPI Mode)
Bit
15
Identifier
-
type
-
Value
0
Description
CC
-
“0” always
14
13
12
11
10
parameter error
address error
-
ERX “0”= no error
“1”= error
An error occurred in command’s parameters.
C
C
-
ERX “0”= no error
“1”= error
A misaligned address which did not match the
block length was used in the command.
Don’t care.
-
x
com crc error
illegal command
-
ER
ER
-
“0”= no error
“1”= error
“0”= no error
“1”= error
x
The CRC check in the immediately previous
command failed.
C
C
-
Command is not legal for the card state.
Don’t care.
08
idle state
SR
“0”= card is ready
“1”= card is in
idle state
A
07
out_of_range
-
ER
-
“0”= no error
“1”= error
The command’s argument was out of the
allowed range for this card.
Don’t care.
C
-
[06:00]
x
13/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
7. REGISTERS
7.1 OCR register (Operation conditions register)
OCR-slice
Field
Status after power up
reserved
Value
Remarks
31
0 or 1
0
[31:24]
23
3.5 – 3.6V
3.4 – 3.5V
3.3 – 3.4V
3.2 – 3.3V
3.1 – 3.2V
3.0 – 3.1V
2.9 – 3.0V
2.8 – 2.9V
2.7 – 2.8V
2.6 – 2.7V
2.5 – 2.6V
2.4 – 2.5V
2.3 – 2.4V
2.2 – 2.3V
2.1 – 2.2V
2.0 – 2.1V
1.9 – 2.0V
1.8 – 1.9V
1.7 – 1.8V
1.65 – 1.70V
1.60 – 1.65V
1.55 – 1.60V
1.50 – 1.55V
1.45 – 1.50V
1
22
1
21
1
20
1
19
1
18
1
17
1
16
1
15
1
14
0
13
0
12
0
11
0
10
0
09
0
08
0
07
0
06
0
05
0
04
0
03
0
02
0
01
0
00
0
7.2 CID register (Card identification register)
This register uses the data written in P2ROM’s particular field.
Bit
Width
8
CID-slice
Name
Field
Value
OKI original
[127:120] Manufacture ID
[119:104] OEM/Application ID
[103:56] Product name
MID
OID
0x41
OKI ID Assigned by MMCA
OKI Device Name
16
0x0000
P2 001
PNM
48
Product Name
[55:48]
[47:16]
[15:8]
Product revision
PRV
PSN
MDT
8
32
8
0x10
Rev. of Product (version 1.0)
Product serial numer
Default=1, settable
Product serial number
Manufacturing data
0x00000001
Month of receiving Date OKI recieved Code file
Code file
CRC
1
from customer or Programmed
check sum
[7:1]
[0:0]
7-bit CRC checksum
-
CRC7
-
7
1
” 1” always
14/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
7.3 CSD register (Card-Specific Data register)
This register uses the data written in P2ROM’s particular field.
Bit
width
2
Value
CSD-slice
Name
Filed
Type
Remarks
Bin.
10
Hex.
0x2
[127:126] CSD Structure
[125:122] spec version
[121:120] reserved
CSD_STRUCTURE
SEPC_VERS
R
R
R
R
Version 3.1
Version 3.1
Don’t care
1ns
4
2
8
0011
X
0x3
X
[119:112] data read access
TAAC
00001000
0x08
time1
[111:104] data read access
time2
NSAC
8
8
00000001
00101010
000000000111
1001
0x01
0x2A
0x007
0x9
R
R
R
R
R
100cycles
20Mb/s
[103:96]
[95:84]
[83:80]
79
max data transfer
rate
card command class
TRAN_SPEED
CCC
12
4
Support
Class0,1,2
512bytes
max read data block
length
partial blocks for read READ_BL_PARTIAL
READ_BL_LEN
1
1
0x1
allowed
78
77
reserved
1
1
X
0
X
R
R
Don’t care
read block
misalignment
READ_BLK_MISALIGN
DSR_IMP
0x0
Crossing
block is not
allowed
76
DSR implemented
1
0
0x0
R
DSR:
Non support
Don’t care
[75:74]
[73:62]
[61:59]
[58:56]
[55:50]
[49:47]
[46:31]
[30:29]
reserved
2
12
3
X
X
0x1FE
0x0
0x4
X
R
R
R
R
R
R
R
R
device size
C_CIZE
000111111110
min. read current
max. read current
reserved
VDD_R_CURR_MIN
VDD_R_CURR_MAX
000
100
X
0.5mA
3
35mA
6
Don’t care
device size multiplier
reserved
C_SIZE_MULT
DEFAULT_ECC
3
000
X
0x0
X
16
2
Don’t care
manufacture default
ECC
reserved
00
0x0
ECC:
Non support
Don’t care
[28:26]
[25:22]
3
4
X
X
R
R
Max. write data
block length
reserved
WRITE_BL_LEN
1001
0x9
[21:16]
15
6
1
1
X
0
0
X
R
R
R
Don’t care
file format group
Copy flag (OTP)
FILE_FORMAT_GRP
COPY
0x0
0x0
14
Default=0,
settable
13
12
permanent write
protection
temporary write
protection
PERM_WRITE_PROTEC
T
TMP_WRITE_PROTECT
1
1
2
2
1
1
0x1
0x1
0x0
0x0
R
R
R
R
[11:10]
[9:8]
file format
FILE_FORMAT
ECC
00
00
Default=0,
settable
ECC:
ECC code
Non support
[7:1]
0
CRC
CRC
7
1
CRC
1
CRC
0x1
R
R
reserved
15/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
*1 Card Capacity
Name
Card Capacity
1MB
C_SIZE_MULT
0
C_SIZE
510
MULT
4
BLOCKNR
2044
BLOCK_LEN
512
MR57T00101F
Cross reference of CSD fields vs command class
Command Classes
CSD Field
0
+
+
1
+
+
+
+
+
+
2
+
+
+
+
+
+
+
+
+
+
+
+
+
+
CSD_STRUCTURE
SEPC_VERS
TAAC
NSAC
TRAN_SPEED
CCC
+
+
READ_BL_LEN
READ_BL_PARTIAL
READ_BLK_MISALIGN
DSR_IMP
+
+
+
+
+
C_CIZE
VDD_R_CURR_MIN
VDD_R_CURR_MAX
DEFAULT_ECC
FILE_FORMAT_GRP….
COPY
+
+
+
+
+
+
+
+
+
PERM_WRITE_PROTECT
TMP_WRITE_PROTECT
FILE_FORMAT
ECC
+
+
+
+
CRC
+
16/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
8. ELECTRICAL CHARACTERISTICS
8.1 General
Parameter
Symbol
Min
-0.3
Max
4.6
Unit
V
Remarks
Absolute maximum
rating
Peak voltage on all line
Input Leakage Current
-10
-10
10
200
10
µA
µA
µA
Input Leakage Current for CS signal
Output Leakage Current
8.2 Recommended operating conditions
Parameter
Symbol
VDD
FOD
Fpp
Min
2.7
Max
3.6
400
20
Unit
V
Remarks
Power supply voltage
Operating frequency (Identification Mode)
Operating frequency (Data Transfer Mode)
Operating temperature
KHz
MHz
°C
Ta
-10
-40
85
Storage temperature
Tstg
85
°C
Absolute maximum
rating
8.3 Open-Drain Bus Signal Level
Parameter
Symbol
VOL
Min
Min
Max
Unit
Condition
IOL=2mA
Output LOW voltage
0.3
V
8.4 Push-Pull bus signal level
Parameter
Symbol
VOH
Max
Unit
V
Condition
IOH=-100µA
@VDD min
IOL=100µA
@VDD min
Output HIGH voltage
VDD-0.2
Output LOW voltage
VOL
0.125*VDD
V
Input HIGH voltage
Input LOW voltage
VIH
VIL
0.625*VDD
VSS-0.3
VDD+0.3
0.25*VDD
V
V
17/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
8.5 Bus Signal Line Load
Parameter
Symbol
Rcs
Min
TYP
50
Max
Unit
KΩ
pF
Condition
Pull-up resistance for CS
Bus signal line capacitance
Bus signal line capacitance
Signal card capacitance
CL
250
100
19
Fpp<= 5MHz
Fpp<= 20MHz
CL
pF
C_CARD
pF
8.6 Supply Current
Parameter
Symbol
IDD
Min
Max
30
Unit
Condition
Supply Current
mA
VDD=2.7~3.6V,
Ta=-10~85°C
at 20MHz
Supply Current
IDDS
200
µA
VDD=2.7~3.6V, CS=VDD,
VIH=VDD, VIL=Vss,
Ta=-10~85°C
at 0MHz (standby)
18/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
8.7 AC Characteristics
(VDD=2.7~3.6V,Ta =-10~+85°C)
Parameter
Clock frequency (Identification Mode)
Clock frequency (Data Transfer Mode)
Clock Low time
Symbol
FOD
Fpp
Min
0
Max
400
20
Unit
KHz
MHz
ns
Remarks
tWL
10
10
CL<=100pF
Clock High time
tWH
tTLH
tTHL
Fpp
ns
Clock rise time
10
10
5
ns
Clock fall time
ns
Clock frequency (Data Transfer Mode)
Clock Low time
MHz
ns
tWL
50
50
CL<=250pF
Clock High time
tWH
tTLH
tTHL
tISU
tIH
ns
Clock rise time
50
50
ns
Clock fall time
ns
Input set-up time
3
3
0
ns
Input hold time
ns
Output set-up time
tdly
15
ns
tPP
CLOCK
tTHL
tTLH
tWL
tWH
tISU
tIH
INPUT
tdly
tdly
OUTPUT
19/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
9. POWER UP
Power up sequence is shown below.
Circuit for detecting power-supply voltage is embedded in this MMC. When the voltage is below a certain value,
power-on reset is generated in order to prevent operation error. As long as enough voltage is reached, the internal
initialization is done automatically.
Vcc
System supply voltage
Minimum operation voltage
for card logic (Vmin)
Time
t3
t2
t1
stable
Parameter
Symbol
Vmin
t1
Min
Max
1.5
Unit
V
Remarks
Min VCC for logic
Power up time-1
Power up time-2
Initialize time
Clock-supply is not allowed
t1+t2
t2+t3
1
ms
37
clock
10. SHORTCUT PROTECTION
Cards shall be inserted/removed into/from the bus without damage. If one of the supply pins (VDD or VSS) is not
connected properly, then the current is drawn through a command line or a data line. In such case, the card cannot
work normally.
The device connector for P2ROM MMC insertion should be connected as following steps, for the length of contact
pins is different (length of VSS, VDD > length of other signals).
Step-1: VSS (pin 3), VDD (pin 4) connection
Step-2: Other signals (pin 1~2, 5~7) connection
20/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
11. CARD DIMENSION DIAGRAM
21/24
FEDR57T00101F-02-03
OKI Semiconductor
MR57T00101F / P2ROM MMC
12. STATE TRANSITION DIAGRAM
Power ON
CS signal="0"
CMD0
SPI mode
MMC mode
GO_IDLE_STATE
CMD1
Idle State
Non compatible voltage range
(idle)
SEND_OP_COND
CMD58
READ_OCR
CMD1
Inactive
SEND_OP_COND
card loose bus
State(ina)
CMD9
SEND_CSD
SEND_CID
Ready State
(ready)
CMD10
CMD15
GO_INACTIVE_STATE
CMD2
ALL_SEND_CID
Identification
State(ident)
CMD18
CMD12
CMD23
CMD59
CMD16
CMD17
CMD13
READ_MULTIPLE
_BLOCK
SET_BLOCK
_COUNT
SEND_STATUS
READ_SINGL
E_BLOCK
SET
CRC_ON_OFF
_BLOCKLEN
CMD3
SET_RELATIVE_ADDR
STOP_TRANSMISSION
Stand-by
State(stby)
CMD10
CMD13
SEND_STATUS
CMD4
NOP
CMD9
CMD7
SEND_CID
SELECT/DESELECT_CARD
SEND_CSD
Transfer
State(tran)
CMD18
CMD13
READ_SINGLE_BLOCK
CMD11
READ_DAT
CMD17
CMD7
CMD23
CMD16
SET_BLOCKLEN
SEND_STATUS
SELECT/DESELE
CT_CARD
READ_MULTIPL
E_BLOCK
SET_BLOCK
_COUNT
_UNTIL_STOP
Sending-data
State(data)
Sending-data
State(data)
CMD12
CMD7
CMD7
STOP
_TRANSMISSION
SELECT/DESELECT
_CARD
SELECT/DESELECT
_CARD
22/24
FEDR57T00101F-02-03
OKI Semiconductor
REVISION HISTORY
Document No.
MR57T00101F / P2ROM MMC
Page
Date
Description
Previous Current
Edition
Edition
FEDR57T00101F-02-01 June 8, 2004
–
1
–
1
Final edition 01
Change headline
8.5 Bus Signal Line Load change following:
Bus signal line capacitance:
Condition: delete “30 cards”
Bus signal line capacitance:
18
18
FEDR57T00101F-02-02 June 25, 2004
Condition: delete “10 cards”
Signal card capacitance: Max 17->19.
8.7 AC Characteristics change following:
Remarks: delete (10cards)
Remarks: delete (30cards)
19
1
19
1
Card name/capacity
change following:
FEDR57T00101F-02-03 Sept. 17, 2004
MR57T00101F -> MR57T00101F-xxxKB
23/24
FEDR57T00101F-02-03
OKI Semiconductor
NOTICE
MR57T00101F / P2ROM MMC
1. The information contained herein can change without notice owing to product and/or technical improvements.
Before using the product, please make sure that the information being referred to is up-to-date.
2. The outline of action and examples for application circuits described herein have been chosen as an explanation
for the standard action and performance of the product. When planning to use the product, please ensure that the
external conditions are reflected in the actual circuit, assembly, and program designs.
3. When designing your product, please use our product below the specified maximum ratings and within the
specified operating ranges including, but not limited to, operating voltage, power dissipation, and operating
temperature.
4. Oki assumes no responsibility or liability whatsoever for any failure or unusual or unexpected operation
resulting from misuse, neglect, improper installation, repair, alteration or accident, improper handling, or
unusual physical or electrical stress including, but not limited to, exposure to parameters beyond the specified
maximum ratings or operation outside the specified operating range.
5. Neither indemnity against nor license of a third party’s industrial and intellectual property right, etc. is granted
by us in connection with the use of the product and/or the information and drawings contained herein. No
responsibility is assumed by us for any infringement of a third party’s right which may result from the use
thereof.
6. The products listed in this document are intended for use in general electronics equipment for commercial
applications (e.g., office automation, communication equipment, measurement equipment, consumer
electronics, etc.). These products are not, unless specifically authorized by Oki, authorized for use in any
system or application that requires special or enhanced quality and reliability characteristics nor in any system
or application where the failure of such system or application may result in the loss or damage of property, or
death or injury to humans.
Such applications include, but are not limited to, traffic and automotive equipment, safety devices, aerospace
equipment, nuclear power control, medical equipment, and life-support systems.
7. Certain products in this document may need government approval before they can be exported to particular
countries. The purchaser assumes the responsibility of determining the legality of export of these products and
will take appropriate and necessary steps at their own expense for these.
8. No part of the contents contained herein may be reprinted or reproduced without our prior permission.
Copyright 2004 Oki Electric Industry Co., Ltd.
24/24
相关型号:
©2020 ICPDF网 联系我们和版权申明