A22E-M-12 [OMRON]

Pushbutton Switch, 3PST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded;
A22E-M-12
型号: A22E-M-12
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Pushbutton Switch, 3PST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded

开关
文件: 总18页 (文件大小:3894K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Emergency Stop Switch (22-dia./25-dia.)  
A22E  
CSM_A22E_DS_E_12_1  
Install in 22-dia. or 25-dia. Panel Cutout  
• Direct opening mechanism to open the circuit when the contact  
welds  
.
• Safety lock mechanism prevents operating errors.  
• Easy mounting and removal of Switch Blocks using a lever.  
• Mount three Switch Units in series to improve wiring efficiency  
(with non-lighted Switch Units, three Units can be mounted for  
multiple contacts).  
• Finger protection mechanism on Switch Unit provided as a  
standard feature.  
• Install using either round, or forked crimp terminals.  
• Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models)  
• A lock plate is provided as a standard feature to ensure that the  
control box and switch are not easily separated.  
Be sure to read the “Safety Precautions” on page 16.  
Model Number Structure  
Model Number Legend (Completely Assembled)........ Shipped as a set which includes the Operation Unit, Lamp  
(lighted models only), and Switch.  
24A 01  
L
M
3. Light Source  
Without Voltage Reduction Unit  
5. Configuration  
1. Lighted/Non-lighted  
Code Description  
None Non-lighted  
Lighted *  
4. Contacts  
Code  
Code  
Configuration  
Description  
Description  
None Non-lighted  
Code  
Operating Voltage  
None Switch only  
01  
11  
SPST-NC  
---  
Switch with Integrated  
Control Box  
B
SPST-NO + SPST-NC  
DPST-NC  
L
6A  
LED  
6 VAC/VDC  
12 VAC/VDC  
24 VAC/VDC  
02  
12  
03  
* Lighted Emergency Stop  
Switches are available only  
for the medium (M).  
12A  
24A  
DPST-NC + SPST-NO  
TPST-NC  
push-lock turn-reset models.  
With Voltage Reduction Unit  
Description  
Code  
Operating Voltage  
2. Head Size  
LED  
T1  
100 VAC  
Code  
Size  
Description  
Push-pull  
Medium  
40 dia.  
T2  
200 VAC  
MP  
Equipped with 24-VAC/DC LED.  
Small  
30 dia.  
Medium  
40 dia.  
S
M
L
Push-lock turn-reset  
Large  
60 dia.  
1
A22E  
Ordering Information  
List of Models (Completely Assembled)  
Non-lighted Models  
Operating  
Set Model  
A22E-MP-01  
Color of cap  
Appearance  
Contact Configuration  
40-dia. head  
Medium Push-pull  
A22E-MP  
SPST-NC  
SPST-NO/SPST-NC  
DPST-NC  
A22E-MP-11  
A22E-MP-02  
30-dia. head  
Small Push-lock  
Turn-reset  
SPST-NC  
A22E-S-01 *  
A22E-S-11 *  
A22E-S-02 *  
A22E-S12 *  
A22E-S-03 *  
A22E-M-01 *  
A22E-M-11 *  
A22E-M-02 *  
A22E-M-12 *  
A22E-M-03 *  
SPST-NO/SPST-NC  
DPST-NC  
A22E-S  
DPST-NC + SPST-NO  
TPST-NC  
Red  
40-dia. head  
Medium Push-lock Turn-reset  
A22E-M  
SPST-NC  
SPST-NO/SPST-NC  
DPST-NC  
DPST-NC + SPST-NO  
TPST-NC  
60-dia. head  
Large Push-lock Turn-reset  
A22E-L  
SPST-NC  
A22E-L-01 *  
A22E-L-11 *  
A22E-L-02 *  
SPST-NO/SPST-NC  
DPST-NC  
* Models with Korean S-mark certification.  
Note: 1. Yellow cap models are also available (not for emergency stop use). Contact your OMRON representative.  
2. The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.)  
With EMO/EMS Indication (non-lighted)  
Operating  
Set Model  
Color of cap  
Appearance  
Contact Configuration  
40-dia. head  
Medium Push-lock Turn-reset  
With EMO Indication  
SPST-NC  
A22E-M-01-EMO *  
A22E-M-11-EMO *  
A22E-M-02-EMO *  
A22E-M-12-EMO *  
A22E-M-03-EMO *  
A22E-M-01-EMS *  
A22E-M-11-EMS *  
A22E-M-02-EMS *  
A22E-M-12-EMS *  
A22E-M-03-EMS *  
SPST-NO/SPST-NC  
DPST-NC  
DPST-NC + SPST-NO  
TPST-NC  
Red  
40-dia. head  
Medium Push-lock Turn-reset  
With EMS Indication  
SPST-NC  
SPST-NO/SPST-NC  
DPST-NC  
DPST-NC + SPST-NO  
TPST-NC  
* Models with Korean S-mark certification.  
Note: The colors of switch blocks are the followings:  
SPST-NO: black  
SPST-NC: red  
The above illustration shows the DPST-NC classification.  
2
A22E  
Lighted Models  
Operating  
Lighting  
Push-lock turn-reset system  
Set Model  
Appearance  
Color of cap  
Contact configuration  
Rated voltage  
40-dia. head  
Push-lock  
Turn-reset without Voltage  
Reduction Unit  
A22E  
6 VAC/VDC  
A22EL-M-6A-01 *  
A22EL-M-12A-01 *  
A22EL-M-24A-01 *  
A22EL-M-6A-11 *  
A22EL-M-12A-11 *  
A22EL-M-24A-11 *  
A22EL-M-6A-02 *  
A22EL-M-12A-02 *  
A22EL-M-24A-02 *  
A22EL-M-T1-01  
SPST-NC  
12 VAC/VDC  
24 VAC/VDC  
6 VAC/VDC  
12 VAC/VDC  
24 VAC/VDC  
6 VAC/VDC  
12 VAC/VDC  
24 VAC/VDC  
100 VAC  
SPST-NO/SPST-NC  
DPST-NC  
LED  
Red  
40-dia. head  
Push-lock  
Turn-reset with Voltage  
Reduction  
Unit  
SPST-NC  
200 VAC  
A22EL-M-T2-01  
100 VAC  
A22EL-M-T1-11  
SPST-NO/SPST-NC  
DPST-NC  
A22E  
200 VAC  
A22EL-M-T2-11  
100 VAC  
A22EL-M-T1-02  
200 VAC  
A22EL-M-T2-02  
* Models with Korean S-mark certification.  
Note: The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.)  
Switch with Integrated Control Box  
Appearance  
Contact configuration  
Model  
SPST-NC  
A22E-M-01B *  
SPST-NO/SPST-NC  
DPST-NC  
A22E-M-11B *  
A22E-M-02B *  
* Models with Korean S-mark certification.  
3
A22E  
Subassembled...........The Operation Unit, Lamp, or Switch can be ordered separately. Use them in combination for models that are not  
available as assembled Units. These can also be used as inventory for maintenance parts.  
Non-lighted  
Operation Unit *1  
Lighted (without Voltage Reduction Unit)  
Operation Unit *1  
Lighted (with Voltage Reduction Unit)  
Operation Unit *1  
Lamp  
Lamp  
Incandescent  
LED  
LED  
Switch *2  
Switch (without Voltage Reduction Unit)  
Switch (with Voltage Reduction Unit)  
*1.The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.)  
*2. Up to three Switch Units can be mounted for multiple contacts.  
4
A22E  
Operation Units  
Non-lighted  
IP65 oil-resistant models  
Medium (40 dia.)  
Sealing capability  
Size  
Function  
Push-pull  
Small (30 dia.)  
Large (60 dia.)  
A22E-MP  
---  
---  
A22E-L  
A22E-S  
A22E-M  
Push-lock, turn-reset  
Lighted  
Sealing capability  
Size  
IP65  
Function  
Medium (40 dia.)  
A22EL-M  
Push-lock, turn-reset  
Note: The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.)  
5
A22E  
Lamp  
LED  
Appearance  
LED light  
Rated voltage  
Model  
A22-6AR  
6 VAC/VDC  
Red Standard 12 VAC/VDC  
24 VAC/VDC  
A22-12AR  
A22-24AR  
Note: For voltage-reduction lighting, use the A22-24AR.  
Incandescent  
Appearance  
Rated voltage  
Model  
A22-5  
6 VDC  
14 VAC  
28 VAC  
130 VAC  
A22-12  
A22-24  
A22-H1  
Switch (Standard Load)  
Without Voltage Reduction Unit  
Classification  
Non-lighted  
Lighted  
Appearance  
Switch Action  
Momentary  
Momentary  
Model  
Contacts  
Model  
SPST-NC  
A22-01M  
A22L-01M  
A22L-11M  
A22L-02M  
For standard loads  
SPST-NO + SPST-NC A22-11M  
DPST-NC A22-02M  
With Voltage Reduction Unit  
Classification  
Lighted (110 VAC)  
Lighted (220 VAC)  
Appearance  
Switch Action  
Momentary  
Model  
Momentary  
Model  
Contacts  
SPST-NC  
SPST-NO + SPST-NC A22L-11M-T1  
DPST-NC A22L-02M-T1  
Note: When using with a Voltage Reduction Unit, use the A22-24AR.  
A22L-01M-T1  
A22L-01M-T2  
For standard loads  
A22L-11M-T2  
A22L-02M-T2  
6
A22E  
Accessories (Order Separately)  
Item  
Appearance  
Classification  
Standard load A22-10  
Microload A22-10S  
Standard load A22-01  
Microload A22-01S  
Standard load A22-20  
Microload A22-20S  
Standard load A22-02  
Model  
Remarks  
SPST-NO  
SPST-NC  
Provided as standard.  
Order Switch Blocks only when adding  
or replacing them.  
Switch Blocks  
DPST-NO,  
one-piece  
DPST-NC,  
one-piece  
Microload  
A22-02S  
A22-TN  
A22-T1  
Direct lighting  
Used when changing the lighting  
method.  
Voltage-  
reduction  
lighting  
100 VAC  
200 VAC  
Lamp Sockets  
A22-T2  
Provided as standard.  
Order Mounting Latches only when  
mounting Switch Blocks or Lamp  
Sockets that are purchased individually.  
Mounting Latches  
---  
A22-3200  
60-dia. black letters on yellow  
back-ground  
A22Z-3466-1  
A22Z-3476-1  
“EMERGENCY STOP” is indicated on  
the plate. *2  
90-dia. black letters on yellow  
back-ground  
Legend Plates for  
Emergency Stop  
60-dia. black letters on yellow  
back-ground  
“EMERGENCY OFF” is indicated on the  
plate.  
A22Z-3466-2  
A22Z-3530  
Can be plugged into pre-cut panel holes  
for future expansion. The color is black.  
Hole Plug  
Round  
7 to 9 dia.  
Applicable  
A22Z-3500-1  
A22Z-3500-2  
Plastic connector used to extend a cable  
from the Switch Box.  
Connectors  
cablediameter  
9 to 11 dia.  
Can be fit into a 25-dia. hole in the panel.  
Since this is not attached to the main  
body, order separately. (Refer to page  
14.)  
25-dia. Ring  
---  
---  
A22Z-R25  
A22Z-A30  
Can be fit into a 30-dia. hole in the panel.  
(Refer to page 14.)  
30-dia. Resin Attachment  
Lock Plate  
---  
A22Z-3380  
Use to fix the lever on the Switch.  
Control Boxes  
(Enclosures)  
One hole, yellow box  
(for emergency stop)  
A22Z-B101Y  
Material: Polycarbonate resin *2  
Operation Keys  
Lock Ring  
---  
A22K-K  
Two keys are provided.  
The body is equipped with a Lock  
Fitting. This Lock Fitting is used when a  
more secure lock feature is required.  
(Refer to page 14.)  
Rounded shape  
A22Z-3360  
Rubber tool used to replace Lamps  
easily  
Lamp Extractor  
Tightening Tool  
---  
---  
A22Z-3901  
A22Z-3905  
Tool used to tighten rings from the back  
of the panel and to attach caps to lighted  
models.  
7
A22E  
Item  
Appearance  
Classification  
Model  
Remarks  
Provides SEMI-S2/SEMATECH  
Application Guide for SEMI-S2  
compatibility. The SEMI-S2-compatible  
Shroud and legend plate for  
EMERGENCY OFF come as a set. Use  
with an A22E Emergency Stop Switch.  
(for emergency shutoff) *1 *2  
E-stop Shroud for EMO,  
Yellow  
---  
A22Z-EG1  
Provides SEMI-S2/SEMATECH  
Legend plate for  
EMERGENCY OFF is not  
included.  
E-stop Shroud for EMO,  
Yellow  
APPLICATION GUIDE FOR SEMI S2  
compatibility. Use with an A22E with  
EMO indication. (for emergency off) *2  
A22Z-EG10  
Provides SEMI-S2/SEMATECH  
Application Guide for SEMI-S2  
compatibility. The SEMI-S2-compatible  
Shroud and legend plate for  
EMERGENCY STOP come as a set.  
Use with an A22E Emergency Stop  
Switch. (for emergency stop) *1*2  
E-stop Shroud for EMS,  
White  
---  
A22Z-EG1-W  
Provides SEMI-S2/SEMATECH  
Legend plate for  
EMERGENCY STOP is not  
included.  
E-stop Shroud for EMS,  
White  
APPLICATION GUIDE FOR SEMI S2  
compatibility. Use with an A22E with EMS  
indication. (for emergency stop) *2  
A22Z-EG10-W  
A22Z-EG2  
SEMI-S2/SEMATECH Application  
Guide for SEMI S2-compatible Shroud.  
(for emergency shutoff) *1*2  
Use together with an A22E Emergency  
Stop Switch.  
E-stop Shroud, Yellow  
---  
*1. These Shrouds are for use with the equipment only that conforms to SEMI standards. Do not use them for any other applications (e.g.  
emergency stop switches for machines or devices such as Machine tools, Printing presses, Industrial machinery, etc).  
*2. The A22-B101Y cannot be used in combination with the A22Z-3476-1 and the A22Z-EG@.  
Note: 1. Accessories for A22Z-EG1: one “EMERGENCY OFF” label, two rubber washers, and one lock ring  
2. Accessories for A22Z-EG10: one rubber washer and one lock ring (without label)  
Specifications  
Certified Standard Ratings  
Certified Standards  
UL, cUL (File No.E41515)  
6A at 220 VAC, 10 A at 110 VAC  
TÜV (EN60947-5-1) (Low Voltage Directive)  
3 A at 220 VAC  
Certification body  
Standards  
File No.  
E41515  
UL *1  
UL508, C22.2 No.14  
EN60947-5-1,  
EN60947-5-5  
(certified direct  
opening mechanism)  
TÜV SÜD  
Inquire  
CCC (GB14048.5)  
3 A at 240 VAC, 1.5 A at 24 VDC  
CQC (CCC)  
GB14048.5  
2003010303070635  
2004-220, 2007-27  
2009-189  
(A22E-@-@-EMS/EMO)  
KOSHA *2  
EN60947-5-1  
Note: Only models with NC contacts have a direct opening mechanism.  
*1. UL-certification for CSA C22.2 No. 14 and bears the mark.  
Certification has been obtained for the Switch Unit and the Lamp Socket.  
*2.Some models have been certified.  
Ratings  
Note: 1. Rated current values are determined according to the  
testing conditions. The above ratings were obtained by  
conducting tests under the following conditions.  
(1) Ambient temperature: 20° 2°C  
Contacts (Standard Load)  
Rated current (A)  
AC12 DC13  
(inductive (resistive (inductive (resistive  
load) load) load) load)  
Rated  
carry  
current  
(A)  
Rated  
voltage  
(V)  
AC15  
DC12  
(2) Ambient humidity: 65 5%  
(3) Operating frequency: 20 operations/minute  
24 VAC  
10  
5
3
10  
10  
6
2. Minimum applicable load: 10 mA at 5 VDC  
110 VAC  
220 VAC  
380 VAC  
440 VAC  
24 VDC  
---  
---  
LED Indicators without Voltage Reduction Unit  
2
3
Rated voltage  
6 VAC/VDC  
Rated current  
Operating voltage  
6 VAC/VDC 5%  
12 VAC/VDC 5%  
24 VAC/VDC 5%  
10  
1
2
1.5  
0.5  
0.2  
0.1  
10  
2
110 VDC  
220 VDC  
380 VDC  
12 VAC/VDC  
24 VAC/VDC  
8 mA  
---  
---  
0.6  
0.2  
8
A22E  
Characteristics  
Type  
Emergency Stop Switches  
Non-lighted model: A22E Lighted model: A22EL  
30 operations/minute *3  
Item  
Mechanical  
Electrical  
Allowable operating  
frequency  
30 operations/minute *3  
100 MΩ min. (at 500 VDC)  
Insulation resistance  
Dielectric strength  
Between terminals of same polarity 2,500 VAC, 50/60 Hz for 1 min  
Between each terminal and ground 2,500 VAC, 50/60 Hz for 1 min  
Vibration resistance *2  
10 to 55 Hz, 1.5-mm double amplitude (within 1 ms)  
1,000 m/s2  
Destruction  
Shock resistance  
Durability  
Malfunction *2  
Mechanical  
Electrical  
250 m/s2 max.  
300,000 operations min. *3  
300,000 operations min. *3  
20 to 70°C  
Ambient operating temperature *1  
Ambient operating humidity  
Ambient storage temperature  
Degree of protection  
20 to 55°C  
IP65 *4  
35% to 85%  
40 to 70°C  
IP65 (oil-resistant) *4  
Class II  
Electric shock protection class  
PTI (tracking characteristic)  
Degree of contamination  
175  
3 (EN60947-5-1)  
*1. With no icing or condensation.  
*2. Malfunction within 1 ms.  
*3. Setting and resetting once is counted as one operation.  
*4. The degree of protection from the front of the panel.  
Structure and Nomenclature  
Operation Unit  
Color: Red  
Non-lighted  
Lighted  
Note: The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.)  
Lamp  
Light source  
LED Lamp  
Incandescent Lamp  
Switch  
Contact Ratings  
10 A at 110 VAC (resistive load)  
10 A at 24 VDC (resistive load)  
Lighting Method  
Non-lighted  
Lighted (without Voltage Reduction Unit)  
Lighted (with Voltage Reduction Unit)  
(The above figures are examples  
of the lighted model.)  
Lock Plate (Attached with the Operation Unit)  
(Refer to the Mounting the Lock Plate on page 16 for use.)  
9
A22E  
Dimensions  
(Unit: mm)  
Non-lighted Models  
A22E-S  
Small Push-lock, Turn-reset (30-dia.)  
A22E-MP  
Medium Push-pull (40-dia.)  
30 dia.  
34  
34  
40 dia.  
1.8  
5.9  
1.8  
5.9  
0.5  
0.5  
54.7  
32  
54.7  
32  
2
A22E-L  
Large Push-lock, Turn-reset (60-dia.)  
A22E-M  
Medium Push-lock, Turn-reset (40-dia.)  
2
1.5  
34  
40 dia.  
34  
60 dia.  
6.5  
1.8  
5.9  
1.8  
5.9  
18.5  
0.5  
0.5  
41.2  
54.7  
32  
54.7  
32  
Note: The dimensions are the same as for EMO/EMS indication  
models.  
Lighted Models  
Switch dimensions when mounted to a DPST-NO  
(or DPST-NC) one-piece Switch Block  
A22EL-M  
Medium Push-lock, Turn-reset (40-dia.)  
2
2
1.5  
24 44  
34  
40 dia.  
57.8  
72.7  
6.5  
1.8  
5.9  
Note: The operation unit is an example for the A22E-M.  
18.5  
0.5  
41.2  
54.7  
32  
Note: The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.)  
10  
A22E  
Dimensions for Accessories  
Hole Plug  
6
30-dia. Resin Attachment  
A22Z-A30  
6.1  
3.8  
20.5  
Round A22Z-3530  
34.7 dia.  
2.8  
30 dia.  
1
22.2 dia.  
13  
2.5  
55  
Lamp Extractor  
A22Z-3901  
Tightening Tool  
A22Z-3905  
17.5  
12.5  
11 dia.  
8 dia.  
8.5 dia.  
30 dia.  
4.5  
20  
90  
2
Material: Chloroprene rubber  
Legend Plates for Emergency Stop  
A22Z-3476-1 (90 dia.)  
A22Z-3466-1 (60 dia.)  
A22Z-3466-2 (60 dia.)  
90 dia.  
60 dia.  
60 dia.  
Black letters  
Black letter  
Yellow  
Black letters  
Yellow  
t1  
Yellow  
t1  
22.2 dia.  
22.2 dia.  
t1  
22.2 dia.  
25-dia. Ring  
A22Z-R25  
Lock Ring  
A22Z-3360  
2
1
22.2 dia.  
30 dia.  
0.5  
1.3  
Material: NBR (black)  
2.8  
Material: Nickel plated on iron  
Lamp  
LED A22-6@, 12@, 24@  
Incandescent Lamp A22-5, 12, 24, H1  
20 1.5  
28 max.  
Model indication  
BA9S/13  
BA9S/13  
Control Box  
A22Z-B101Y (1 hole)  
Cable Draw-out Hole (Top View)  
4-4 × 38 tapping screw  
0.3  
0.1  
22.1  
dia.  
Mounting Hole  
2-R3  
Two, 21 dia.  
Side lead draw-out hole  
4.3  
6.3  
16 1 dia.  
(Side lead draw-out hole)  
10  
Two, mounting holes  
20.5 0.1  
32  
39  
20  
(10 × 36) 0.6 depression  
75  
41  
69.5  
11  
A22E  
E-stop Shroud  
A22Z-EG1, A22Z-EG1-W,A22Z-EG10,A22Z-EG10-W  
75  
63  
38  
52.2 max.  
75 min.  
(Determined by the  
height of the Switch  
surface in the  
lock position.)  
Panel Cutout Dimensions  
5R  
2.8  
22.3+0.4  
0
90 dia. 78 dia.  
0.2  
20.5  
24.2  
40  
30  
1.7R+0.1  
22.2 dia.  
0
33 dia.  
Allowable panel thickness: 1 to 3 mm  
Switch Unit  
A22E-M  
Panel  
EMERGENCY OFF  
inscription plate (t=1)  
+0.5  
1.5  
8
2.5  
Note: 1. The dimensions of the Shroud  
conform to the specifications of  
the SEMATECH Application  
Guide for SEMI S2-93.  
Rubber packing (t=0.5)  
Switch guard  
Sunken  
section, 0.2  
2. The Shroud is not provided with  
the Switch.  
Rubber packing (t=0.5)  
Mounting panel  
“EMERGENCY STOP” is indicated  
on A22Z-EG1-W.  
Legend plate is not provided with  
A22Z-EG10 and A22Z-EG10-W.  
2
1
Locking ring  
E-stop Shroud  
A22Z-EG2, A22Z-EG21, A22Z-EG22  
105 dia.  
98 dia.  
79 dia.  
3
35  
12  
2.8  
20.6  
M90  
Detents  
inside  
(One on  
each side)  
22.2 dia.  
2R  
The number of spacers depends  
on the model  
A22Z-EG2 : No Spacer  
A22Z-EG21 : 1 Spacer  
A22Z-EG22 : 2 Spacers  
Mounting with Spacers  
With 1 Spacer  
With 2 Spacers  
Mounting a 1-pole Switch Unit *  
Mounting a 2-pole Switch Unit *  
Spacer  
Spacers  
Panel Cutout Dimensions  
DPST-NC One-piece  
Contact Unit  
NC Contact Unit  
90.3+0.4 dia.  
Position of  
detent  
notch  
Position of  
detent  
notch  
0
5.5+0.2  
0
95+0.2  
0
10  
13  
20  
23  
Panel  
Panel  
Panel  
Panel  
88 max.  
105 max.  
Note: 1. The dimensions of the Shroud conform to the  
specifications of the SEMATECH Application  
Guide for SEMI S2-93.  
2. The Shroud is not provided with the Switch.  
3. Tighten to a torque of 1.96 to 2.94 Nm.  
4. The allowable panel thicknesses are as follows:  
Without Spacers: t=1.3 to 22.5 mm  
With 1 Spacer: t=1.3 to 12.5 mm  
With 2 Spacers: t=1.3 to 2.5 mm  
* These are the dimension from the front of the panel when  
the Switch Unit is attached.  
12  
A22E  
Panel Cutouts  
0.8R max.  
3.2+0.2  
0
24.1+0.4  
0
22.3+0.4 dia.  
25+0.5 dia.  
0
22.3+0.4 dia.  
0
0
With Lock Fitting  
Without Lock Fitting  
A Lock Ring is provided as a standard feature.  
When painting or coating the panel, make sure that the specified  
panel dimensions apply to the panel after painting or coating.  
Use an A22Z-R25 Ring when mounting to a panel with a  
25-mm diameter hole.  
Terminal Arrangement (Bottom View)  
Non-lighted (two contacts)  
Non-lilghted (three contacts)  
Lighted  
Switch  
10  
20.7  
10  
Blocks  
16.7  
16.7  
22  
M3.5 screws  
Switch Blocks  
Switch Blocks  
Lamp Socket  
Terminal Connection  
Terminal connection (BOTTOM VIEW)  
Type  
SPST-NO + SPST-NC  
DPST-NC  
DPST-NC + SPST-NO  
TPST-NC  
1
2
3
1
2
1
2
1
1
3
1
2
1
1
2
Non-lighted  
4
2
2
4
2
1
2
X1  
X2  
3
4
1
2
X1  
1
2
Lighted without Voltage  
Reduction Unit  
X
X
X2  
1
2
X1  
X2  
1
2
X1  
X2  
1
2
3
4
Lighted with Voltage  
Reduction Unit  
X
X
Note: The above terminal connection diagrams are examples for SPST-NO + SPST-NC and DPST-NC.  
13  
A22E  
Installation  
Mounting to the Panel  
(1) Preparing the Panel  
(2) Mounting the Operation Unit on the Panel  
• The panel dimensions are shown below.  
• The panel thickness must be 1 to 5 mm.  
• Insert the Operation Unit from the front surface of the panel, insert the Lock Ring and  
the mounting Ring from the terminal side, then tighten the Ring. Before tightening,  
check that the rubber washer is present between the Operation Unit and the panel.  
0.8R max.  
3.2+0.2  
• Align the Lock Ring with the groove in the casing, then insert the Lock Ring so that  
its edge is located on the panel side.  
0
• Tighten the mounting nut at a torque of 0.98 to 1.96 N·m.  
24.1+0.4  
0
• When using a Lock Ring, replace with the supplied Lock Ring, insert the projecting  
part into the lock slot, and then tighten the mounting Ring.  
Hold here  
Panel  
Projecting  
Rubber washer  
Mounting Ring  
22.3+0.4 dia.  
22.3+0.4 dia.  
25+0.5 dia.  
0
0
0
With Lock Ring  
Without Lock Ring  
part  
• Always use a 25-mm-dia. Lock Ring for a 25-mm-dia. hole.  
IP65 degree of protection will be lost if the 25-mm-dia. Lock Ring is not  
used because of the larger size of a 25-mm-dia. hole.  
• When painting or coating the panel, make sure that the specified panel  
dimensions apply to the panel after painting or coating.  
Lock Ring  
(3) Mounting the Switch on the Operation Unit  
Lock Ring  
• Insert the Operation Unit into the Switch Unit, aligning the arrow mark  
inscribed on the Case with the lever on the Switch Blocks, then move the  
lever in the direction indicated by the arrow in the following figure.  
Panel  
1. When the panel cutout dimension is 2. When the panel cutout  
Lever  
25 dia., remove the supplied rubber  
washer and mount the 25-dia. Ring  
as shown below. (Since the A22Z-  
R25 is not attached to the main body,  
order separately.) When using a  
Legend Plate (sold separately), do  
not remove the rubber washer.  
Operation Unit  
dimension is 30 dia., use resin  
attachment A22Z-A30. Since it  
is not attached to the main  
body, order separately.  
Arrow mark  
Operation  
Unit  
Operation Unit  
Rubber washer  
(mounted to  
Operation Unit)  
When not using a  
Legend Plate,  
remove the rubber  
washer.  
Rubber washer  
(mounted to  
Operation Unit)  
(4) Removing the Switch  
(If required)  
Legend Plates for  
Emergency Stop  
(sold separately)  
30-dia.  
Resin Attachment  
(A22Z-A30)  
22 dia.  
• Move the lever in the direction indicated by the arrow in the following  
figure, then pull the Operation Unit or the Switch Blocks.  
Since the lever has a hole with an inside diameter of 6.5 mm, the lever can  
be moved in the specified direction by inserting a screwdriver into the hole  
and then moving the screwdriver.  
Rubber washer  
(included)  
25-dia. Ring  
(A22Z-R25)  
Mounting  
panel  
Lock Ring  
0.5 1.3  
22.3 dia.  
25 dia.  
Mounting  
Ring  
Screwdriver  
25 dia.  
Panel  
22.3 dia.  
Lock Ring  
Mounting Ring  
14  
A22E  
Assembling the Cap  
Emergency Stop Switch  
• Insert the protrusion of the Tightening Wrench (A22Z-3905) into the Cap slot and then turn to remove the Cap.  
Cap slot Protrusion  
Installing/Replacing the Lamp  
(1) Installing/Replacing from the Panel Surface  
(2) Installing/Replacing on the Switch  
• Insert the Lamp Extractor (A22Z-3901) into the lamp, then rotate the Extractor • Grip the indicator with your fingers, then rotate the indicator while pressing it  
while pressing it.  
against the Switch.  
Control Box (Enclosure)  
(1) Mounting the Switch  
(2) Creating a Cable Port Hole  
(3) Securing the Connector Cable  
The Standard-size Legend Plate Frame can Place the tip of a screwdriver on the surface 1. Insert the connector into the cable port hole in the Box and secure  
be mounted.  
where the cable port hole is to be created  
with the Mounting Ring inside the box.  
2. Pass the tightening cap through the cable, insert the cable into the  
Mount the Frame as shown in the following with the cover attached and strike the  
diagram. Mount the Switch in the same way screwdriver to punch a hole.  
connector, and tighten the tightening cap to secure the cable.  
as for an ordinary panel.  
Attempts to punch a hole on the other side  
of the case will damage the Box.  
Rubber washer  
Mounting  
RIng  
Connector  
Snap-in Legend Plate  
Tightening cap  
Cable  
Cable diameter  
Connector  
Inside  
Outside  
7 to 9 dia.  
A22Z-3500-1  
A22Z-3500-2  
Box  
9 to 11 dia.  
15  
A22E  
Installing/Removing the Switch Blocks  
(1) Installing the Switch Blocks  
(2) Removing the Switch Blocks  
Wiring  
• Hook the small protrusion on the Mounting Latch  
into the groove on the other side of the lever, then  
push up the Switch Block in the direction indicated  
by the arrow in the figure below.  
• Insert a screwdriver between the Mounting Latch  
and the Switch Block, then push down the  
screwdriver in the direction indicated by the arrow  
in the following figure.  
• Loosen the terminal screw from the Switch  
Unit until it completely comes off the groove,  
insert a screwdriver as shown in the following  
figure, then push up the washer in the  
direction indicated by the arrow to temporarily  
secure it.  
Now, a round crimp terminal can be  
connected. After inserting the terminal, tighten  
the screws to complete wiring.  
Lever  
Washer  
Mounting  
Latch  
Screwdriver  
Screw  
Protrusion  
Screwdriver  
Use either of the following screwdrivers.  
Switch block  
3 to 6 mm  
Flat-head screwdriver  
3 to 6 mm dia.  
Phillips screwdriver  
Safety Precautions  
Be sure to read the precautions for all A22E models in the website at: http://www.ia.omron.com/.  
Precautions for Correct Use  
!CAUTION  
Mounting  
Do not apply a voltage exceeding the rated voltage across  
the incandescent lamp terminals.  
Always make sure that the power is turned OFF before wiring the  
Switch. Also, do not touch the terminals or other current-carrying  
ports while power is being supplied. Electric shock may occur.  
Do not tighten the mounting ring more than necessary using tools  
such as pointed-nose pliers. Doing so will damage the mounting  
ring. The tightening torque is 0.98 to 1.96 N·m.  
Recommended panel thickness: 1 to 5 mm.  
When mounting the caps after changing the LED or the caps,  
tighten the caps at a tightening torque of 0.49 tp 0.78 N·m.  
The lamp may be destroyed and the operation unit may fly  
out.  
If the Operation Unit is separated from the Socket Unit, the  
equipment will not stop, creating a hazardous condition.  
Secure the lever on the Socket Unit by using the  
A22Z-3380 Lock Plate so that the Operation Unit cannot  
be easily separated from the Socket Unit.  
(Refer to “Mounting the Lock Plate” at the right.)  
Mounting the Lock Plate  
1. Confirm that the lever on the Mounting Latch is on the side where  
the Operation Unit is secured and then insert the protrusion on the  
Lock Plate into the hole in the lever on the Mounting Latch.  
2. Press the hole on the Lock Plate onto the protrusion on the  
Mounting Latch until it clicks into place.  
Lever  
Lock Plate  
2
1
Operation  
Unit  
Mounting Latch  
16  
A22E  
Wiring  
Using the Microload  
Terminal screws must be Phillips or slotted M3.5 screws with a  
square washer.  
Contact failure may occur if a Switch designed for a standard load is  
used to switch a microload. Use Switches within the application  
ranges shown in the following graph. Even within the application  
range, insert a contact protection circuit, if necessary, to prevent the  
reduction of life expectancy due to extreme wear on the  
contacts caused by loads where inrush current occurs when the  
contact is opened and closed.  
The tightening torque is 1.08 to 1.27 N·m.  
Single wires, stranded wires, and crimp terminals can be  
connected to the Switch.  
Applicable Wiring Materials:  
Twisted strands: 2 mm2 max.  
Solid wire: 1.6 mm dia. max.  
Naked Crimp Terminals  
The minimum applicable load is the N-level reference value. This  
value indicates the malfunction reference level for the reliability  
level of 60% (λ 60) (conforming to JIS C5003).  
8 mm max.  
8 mm dia. max.  
The equation, λ 60 = 0.5 x 106/time indicates that the estimated  
malfunction rate is less than 1/2,000,000 with a reliability level of 60%.  
16.0 mm max.  
16.0 mm max.  
Crimp Terminals with  
Insulating Sheaths  
8 mm max.  
8 mm dia. max.  
100 mA  
0.16 mA  
1.6 mA  
30  
24  
20.2 mm max.  
20.2 mm max.  
Area of  
use  
Microload area  
Standard  
load area  
After wiring the Switch, maintain an appropriate clearance and  
creepage distance.  
12  
Invalid  
area  
Operating Environment  
The IP65 model is designed with a protective structure so that it will  
not sustain damage if it is subjected to water from any direction to  
the front of the panel.  
5
0
10 mA  
10  
1 mA  
1
0.1  
100  
1,000  
Current (mA)  
The Switch is intended for indoor use only. Using the Switch  
outdoor may cause it to fail.  
Others  
If the panel is to be coated, make sure that the panel meets the  
specified dimensions after coating.  
Due to the structure of the Switch, severe shock or vibration may  
cause malfunctions or damage to the Switch.  
Also, most Switches are made from resin and will be damaged if  
they come into contact with sharp objects. Particularly scratches  
on the Operation Unit may create visual and operational  
obtrusions.  
LEDs  
The LED current-limiting resistor is built-in, so internal resistance is  
not required.  
If commercially available LEDs are used, select the ones that meet  
the following conditions:  
Base: BA9S/13  
Overall length: 26 mm max.  
Power consumption: 2.6 W max.  
Handle the Switches with care, and do not throw or drop them.  
When DC-specific LEDs are used, wire the Switch so that the X1  
terminal is positive.  
Mis-lighting of the LED  
The LED lights with approx. 0.1 mA or less of micro-current. Take  
a countermeasure like adding a resistor to prevent mis-lighting in  
parallel to the LED.  
The micro-current varies with the machine (leak current or stray  
capacity between cables, etc.). Select resistance value and  
allowable power consumption that meet the actual current.  
Do not allow the  
Switch to drop and hit  
the floor.  
(Circuit example)  
In case of using 24 VAC/VDC, Direct lighting  
X1  
LED  
lamp  
R:10kΩ (1W)  
Bleeder resistor  
Do not place or drop  
heavy objects on the  
Switch.  
X2  
Do not operate the  
Switch with hard or  
sharp objects.  
Hammer  
Screwdriver  
17  
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2012.4  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2012 All Right Reserved.  

相关型号:

A22E-M-12-EMO

Pushbutton Switch, 3PST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-M-12-EMS

Pushbutton Switch, 3PST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-MK-02

Pushbutton Switch, DPST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded,
OMRON

A22E-MP-01

Pushbutton Switch, SPST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-MP-02

Pushbutton Switch, DPST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-MP-11

Pushbutton Switch, SPST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-S-01

Pushbutton Switch, SPST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-S-02

Pushbutton Switch, DPST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-S-03

Pushbutton Switch, 3PST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-S-11

Pushbutton Switch, SPST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-S12

Pushbutton Switch, 3PST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded
OMRON

A22E-SK-02

Pushbutton Switch, DPST, Momentary, 10A, 24VDC, Screw Terminal, Panel Mount-threaded,
OMRON