A3PA-90C11-24EO [OMRON]
Pushbutton Switch, DPDT, Momentary, Quick Connect/solder Terminal, Panel Mount;型号: | A3PA-90C11-24EO |
厂家: | OMRON ELECTRONICS LLC |
描述: | Pushbutton Switch, DPDT, Momentary, Quick Connect/solder Terminal, Panel Mount 光电二极管 |
文件: | 总27页 (文件大小:2385K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Lighted Pushbutton Switch (Square)
A3P
CSM_A3P_DS_E_5_1
Large Square-bodied Lighted
Pushbutton Switches
• Excellent operating sensitivity.
• Excellent illumination with even surface brightness.
• Three-color models (green, orange, red; chameleon lighting)
included in lineup.
Refer to Safety Precautions for All Pushbutton Switches
and Safety Precautions on page 24.
List of Models
Model
Appearance
52 max.
6.7
A3PJ
(Rectangular)
25
32
52 max.
6.7
A3PA
(Square)
25
25
52 max.
6.4
A3PT
(Round)
32 dia.
Note: The A3PJ is shown in the figure above as an example.
■ Specifications: Refer to page 15. ■ Panel cutout: Refer to page 21. ■ Dimensions: Refer to page 18.
■ Accessories, replacements, and tools: Refer to pages 13 to 15. ■ Precautions for correct use: Refer to page 24.
1
A3P
Model Number Structure
Model Number Legend ..... The model numbers used to order sets of Units are illustrated below. One set comprises the Pushbutton,
Lamp, and Switch.
For information on combinations, refer to Ordering Information on pages 3 to 7.
(5) (6)
24E R ............... Single screen
Upper Lower
(1)
(2) (3) (4)
A 3 P J - 90 B 1 1 - 24E RW ................... Horizontal 2-split screen
R (Red)
Upper
W (White) Lower
(1) Shape of
Pushbutton
(2) Switch
Specifications
Standard Load
(3) Screen Pattern
(4) Case Color (5) Lighting
(6) Color of Pushbutton
Method
For LED
Illumination-only models
Sym-
bol
Color
Symbol
Shape
Symbol
Screen pattern
LED-lighted Models
(A3PJ and A3PA
Models Only)
Symbol
R
Color
Red
1
Black
Symbol
Operation
Rectan-
gular
J
Single screen
Light
gray
A
B
C
D
Momentary
Alternate
Momentary
Alternate
1
2
O
orange
green
white
SPDT
A
T
Square
Round
G
Rated
Symbol
Note: A3PT
models are
voltage
W
DPDT
2-split screen
Chameleon *1
Momentary opera-
tion: Self-resetting
Alternate opera-
tion: Self-holding
2
available in
light gray
only.
05E
5 VDC
K
Chameleon
12E 12 VDC
24E 24 VDC
• The chameleon
screen pattern is not
available with A3PT
models.
• The chameleon
screen pattern is only
available with 12 or
24-VDC models.
Microload
Symbol
Operation
E
F
Momentary
LED Lamp-
lighted Models
(A3PT Only)
SPDT
Alternate
Momentary
Alternate
G
Note: 1. The chameleon screen pattern
is not available with A3PT models.
2. The chameleon screen pattern
is only available with 12 or 24-VDC
models.
G
H
DPDT
Rated
Symbol
For Incandescent
Lamp
• Standard Load
250 VAC, 3 A
30 VDC, 3 A
• Microload
125 VAC, 0.1 A
30 VDC, 0.1 A
voltage
*1. With chameleon models, the whole
screen lights red, green, or orange.
When not lit, the display is white.
05C
5 VDC
12C 12 VDC
24C 24 VDC
Symbol
Color
•
The available rectangular models are
shown below. Select from among the
individual products shown on page 10.
Red,
orange,
white,
blue,
• A3PJ and A3PA
can also be
ordered
separately. Refer
to page 10 for
details.
Incandescent
Lamp-lighted
Models
No
symbol
Minimum applicable load
5 VDC, 1 mA
Vertical 2-split
screen models
4-split screen
models
green
• 3PDT models are also
available.
Select from among the
individual products shown on
page 12.
• Includes colored
plate. Refer to page
11 for details.
Vertical 3-split
screen models
Horizontal 3-split
screen models
Rated
Symbol
The above diagrams show the Switches
with the " " mark facing down.
voltage
06
14
28
6 VAC/VDC
14 VAC/VDC
28 VAC/VDC
Colored-illumination models up
to the 4-split screen models are
available as individual Units.
Refer to page 8.
“Colored-illumination” models
operate in the way shown below:
Unlit
Lit
White
Color
The built-in LED
is colored.
Number of LED Lamps
Number of Incandescent Lamps
Screen pattern
Single screen
A3PJ
A3PA
A3PT
2
Screen pattern
Single screen
A3PJ
2
A3PA
A3PT
2
1
Models with built-in LED
Horizontal 2-split screen
Vertical 2-split screen
Horizontal 3-split screen
Vertical 3-split screen
4-split screen
---
Horizontal 2-split screen
Vertical 2-split screen
Horizontal 3-split screen
4-split screen
2
---
---
---
---
4(Low-pow-
er incan-
descent
lamp)
---
---
---
4
---
*2
---
Note: Lamp positions for single-screen A3PJ (rectangular model).
*2. These split screen models are available only as individual Units.
They cannot be ordered as sets.
2
A3P
Ordering Information
Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Not all combinations are possible. Ask your OMRON representative for details.)
(Single Screen)
(Single Screen)
(1)
Rectangular
Models
A3PJ
Standard Loads
Contact type
Operation
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Pushbutton
color
Momentary operation (Self-resetting)
Alternate operation (Self-holding)
symbol
Case color
Black
Light gray
Black
Light gray
Output
SPDT
Lighting
5 VDC
A3PJ-90A11-05E(1)
A3PJ-90A11-12E(1)
A3PJ-90A12-05E(1)
A3PJ-90A12-12E(1)
A3PJ-90B11-05E(1)
A3PJ-90B11-12E(1)
A3PJ-90B12-05E(1)
A3PJ-90B12-12E(1)
R
O
G
W
12 VDC
24 VDC
LED
A3PJ-90A11-24E(1)
A3PJ-90A12-24E(1)
A3PJ-90B11-24E(1)
A3PJ-90B12-24E(1)
12 VDC
A3PJ-90AG1-12EK
A3PJ-90AG1-24EK
A3PJ-90A11-06
---
A3PJ-90BG1-12EK
A3PJ-90BG1-24EK
A3PJ-90B11-06
A3PJ-90BG2-12EK
A3PJ-90BG2-24EK
A3PJ-90B12-06
Chameleon
*1
24 VDC
A3PJ-90AG2-24EK
A3PJ-90A12-06
A3PJ-90A12-14
A3PJ-90A12-28
A3PJ-90C12-05E(1)
A3PJ-90C12-12E(1)
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
5 VDC
Incandescent
lamp
A3PJ-90A11-14
A3PJ-90B11-14
A3PJ-90B12-14
*2
A3PJ-90A11-28
A3PJ-90B11-28
A3PJ-90B12-28
A3PJ-90C11-05E(1)
A3PJ-90C11-12E(1)
A3PJ-90D11-05E(1)
A3PJ-90D11-12E(1)
A3PJ-90D12-05E(1)
A3PJ-90D12-12E(1)
R
O
G
W
12 VDC
LED
24 VDC
A3PJ-90C11-24E(1)
A3PJ-90C12-24E(1)
A3PJ-90D11-24E(1)
A3PJ-90D12-24E(1)
12 VDC
A3PJ-90CG1-12EK
A3PJ-90CG1-24EK
A3PJ-90C11-06
A3PJ-90C11-14
A3PJ-90C11-28
A3PJ-90CG2-12EK
A3PJ-90CG2-24EK
A3PJ-90C12-06
A3PJ-90C12-14
A3PJ-90C12-28
A3PJ-90DG1-12EK
A3PJ-90DG1-24EK
A3PJ-90D11-06
A3PJ-90D11-14
A3PJ-90D11-28
---
DPDT
Chameleon
*1
24 VDC
A3PJ-90DG2-24EK
A3PJ-90D12-06
A3PJ-90D12-14
A3PJ-90D12-28
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
Incandescent
lamp
*2
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PJ-90A11-24E R
*1. You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 20 for details.
*2. Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use the appropriate combination.
Microloads
Contact type Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A)
Operation
Momentary operation (Self-resetting)
Pushbutton
color symbol
Case color
Black
Light gray
Output
SPDT
Lighting
5 VDC
A3PJ-90E11-05E(1)
A3PJ-90E11-12E(1)
A3PJ-90E12-05E(1)
A3PJ-90E12-12E(1)
R
O
G
W
12 VDC
24 VDC
LED
A3PJ-90E11-24E(1)
A3PJ-90E12-24E(1)
12 VDC
A3PJ-90EG1-12EK
A3PJ-90EG1-24EK
A3PJ-90E11-06
---
A3PJ-90EG2-24EK
A3PJ-90E12-06
---
Chameleon
*1
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
5 VDC
Incandescent
lamp
A3PJ-90E11-14
*2
A3PJ-90E11-28
A3PJ-90E12-28
---
A3PJ-90G11-05E(1)
A3PJ-90G11-12E(1)
R
O
G
W
12 VDC
A3PJ-90G12-12E(1)
LED
24 VDC
A3PJ-90G11-24E(1)
A3PJ-90G12-24E(1)
12 VDC
A3PJ-90GG1-12EK
A3PJ-90GG1-24EK
A3PJ-90G11-06
A3PJ-90G11-14
A3PJ-90G11-28
DPDT
Chameleon
---
*1
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
A3PJ-90G12-06
A3PJ-90G12-14
A3PJ-90G12-28
Incandescent
lamp
*2
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PJ-90E11-24E R
*1. You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 20 for details.
*2. Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use the appropriate combination.
Individual models: Refer to pages 9 to 12.
■ Specifications: Refer to page 15
. ■ Dimensions: Refer to page 18.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■ Accessories: Refer to pages 13 to 15.
3
A3P
Ordering Information
Ordering as a Set..................................The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Not all combinations are possible. Ask your OMRON representative for details.)
(1)
(Horizontal 2-split Screen)
(Horizontal 2-split Screen)
Rectangular
Models
(2)
A3PJ
Standard Loads
Contact type
Operation
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Momentary operation (Self-resetting) Alternate operation (Self-holding)
Pushbutton
color symbol
Case color
Black
Light gray
Black
Light gray
Output
SPDT
Lighting
LED
5 VDC
A3PJ-90A21-24E(1)(2) A3PJ-90A22-24E(1)(2) A3PJ-90B21-24E(1)(2) A3PJ-90B22-24E(1)(2)
R O G W
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
24 VDC
A3PJ-90A21-06
A3PJ-90A21-14
A3PJ-90A21-28
A3PJ-90A22-06
A3PJ-90A22-14
A3PJ-90A22-28
A3PJ-90B21-06
A3PJ-90B21-14
A3PJ-90B21-28
A3PJ-90B22-06
A3PJ-90B22-14
A3PJ-90B22-28
Incandescent
lamp
*
LED
A3PJ-90C21-24E(1)(2) A3PJ-90C22-24E(1)(2) A3PJ-90D21-24E(1)(2) A3PJ-90D22-24E(1)(2)
R O G W
*
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
A3PJ-90C21-06
A3PJ-90C21-14
A3PJ-90C21-28
A3PJ-90C22-06
A3PJ-90C22-14
A3PJ-90C22-28
A3PJ-90D21-06
A3PJ-90D21-14
A3PJ-90D21-28
A3PJ-90D22-06
A3PJ-90D22-14
A3PJ-90D22-28
DPDT
Incandescent
lamp
Note: Enter the desired color symbols for the Pushbutton in (1) and (2). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example:
Red
White Lower
Upper A3PJ-90D21-24E R W
Red White
* Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milky white and transparent). Use the appropriate
combination.
(1)
(Horizontal 2-split Screen)
(Horizontal 2-split Screen)
Rectangular
Models
(2)
A3PJ
Microloads
Contact type
Operation
Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A)
Momentary operation (Self-resetting)
Pushbutton
color symbol
Case color
Black
Light gray
Output
SPDT
Lighting
LED
5 VDC
A3PJ-90E21-24E(1)(2)
A3PJ-90E21-06
A3PJ-90E22-24E(1)(2)
A3PJ-90E22-06
R O G W
6 VDC/VAC
Incandescent
lamp
14 VDC/VAC
28 VDC/VAC
5 VDC
A3PJ-90E21-14
A3PJ-90E22-14
*
A3PJ-90E21-28
A3PJ-90E22-28
LED
A3PJ-90G21-24E(1)(2)
A3PJ-90G21-06
A3PJ-90G21-14
A3PJ-90G21-28
A3PJ-90G22-24E(1)(2)
A3PJ-90G22-06
A3PJ-90G22-14
A3PJ-90G22-28
R O G W
*
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
DPDT
Incandescent
lamp
Note: Enter the desired color symbols for the Pushbutton in (1) and (2). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example:
Red
White Lower
Upper A3PJ-90D21-24E R W
Red White
* Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milky-white and transparent). Use the appropriate
combination.
Individual models: Refer to pages 9 to 12.
■ Specifications: Refer to page 15
. ■ Dimensions: Refer to page 18.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■ Accessories: Refer to pages 13 to 15.
4
A3P
Ordering Information
Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Not all combinations are possible. Ask your OMRON representative for details.)
(Single Screen)
(Single Screen)
Square
Models
(1)
A3PA
Standard Loads
Contact type
Operation
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Momentary operation (Self-resetting)
Alternate operation (Self-holding)
Pushbutton
color symbol
Case color
Black
Light gray
Black
Light gray
Output
SPDT
Lighting
5 VDC
A3PA-90A11-05E(1)
A3PA-90A11-12E(1)
A3PA-90A12-05E(1)
A3PA-90A12-12E(1)
A3PA-90B11-05E(1)
A3PA-90B11-12E(1)
A3PA-90B12-05E(1)
A3PA-90B12-12E(1)
R
O
G
W
12 VDC
24 VDC
LED
A3PA-90A11-24E(1)
A3PA-90A12-24E(1)
A3PA-90B11-24E(1)
A3PA-90B12-24E(1)
12 VDC
A3PA-90AG1-12EK
A3PA-90AG1-24EK
A3PA-90A11-06
A3PA-90AG2-12EK
A3PA-90AG2-24EK
A3PA-90A12-06
A3PA-90BG1-12EK
A3PA-90BG1-24EK
A3PA-90B11-06
A3PA-90BG2-12EK
A3PA-90BG2-24EK
A3PA-90B12-06
Chameleon
*1
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
5 VDC
Incandescent
lamp
A3PA-90A11-14
A3PA-90A12-14
A3PA-90B11-14
A3PA-90B12-14
*2
A3PA-90A11-28
A3PA-90A12-28
A3PA-90B11-28
A3PA-90B12-28
A3PA-90C11-05E(1)
A3PA-90C11-12E(1)
A3PA-90C12-05E(1)
A3PA-90C12-12E(1)
A3PA-90D11-05E(1)
A3PA-90D11-12E(1)
A3PA-90D12-05E(1)
A3PA-90D12-12E(1)
R
O
G
W
12 VDC
LED
24 VDC
A3PA-90C11-24E(1)
A3PA-90C12-24E(1)
A3PA-90D11-24E(1)
A3PA-90D12-24E(1)
12 VDC
A3PA-90CG1-12EK
A3PA-90CG1-24EK
A3PA-90C11-06
A3PA-90C11-14
A3PA-90C11-28
A3PA-90CG2-12EK
A3PA-90CG2-24EK
A3PA-90C12-06
A3PA-90C12-14
A3PA-90C12-28
A3PA-90DG1-12EK
A3PA-90DG1-24EK
A3PA-90D11-06
A3PA-90D11-14
A3PA-90D11-28
A3PA-90DG2-12EK
A3PA-90DG2-24EK
A3PA-90D12-06
A3PA-90D12-14
A3PA-90D12-28
DPDT
Chameleon
*1
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
Incandescent
lamp
*2
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PA-90A11-24E R
*1. You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 20 for details.
*2. Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use the appropriate combination.
Microloads
Contact type Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A)
Operation
Momentary operation (Self-resetting)
Pushbutton
color symbol
Case color
Black Light gray
Output
SPDT
Lighting
5 VDC
A3PA-90E11-05E(1) A3PA-90E12-05E(1)
A3PA-90E11-12E(1) A3PA-90E12-12E(1)
R
O
G
W
12 VDC
24 VDC
LED
A3PA-90E11-24E(1) A3PA-90E12-24E(1)
12 VDC
A3PA-90EG1-12EK
A3PA-90EG1-24EK
A3PA-90E11-06
---
---
Chameleon
*1
24 VDC
A3PA-90EG2-24EK
A3PA-90E12-06
A3PA-90E12-14
A3PA-90E12-28
---
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
5 VDC
Incandescent
lamp
*2
A3PA-90E11-28
---
R
O
G
W
12 VDC
A3PA-90G11-12E(1) A3PA-90G12-12E(1)
A3PA-90G11-24E(1) A3PA-90G12-24E(1)
LED
24 VDC
12 VDC
A3PA-90GG1-12EK
---
DPDT
Chameleon
*1
24 VDC
A3PA-90GG1-24EK
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
A3PA-90G11-06
---
A3PA-90G12-06
---
Incandescent
lamp
*2
A3PA-90G11-28
A3PA-90G12-28
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PA-90E11-24E R
*1. You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 20 for details.
*2. Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use the appropriate combination.
Individual models: Refer to pages 9 to 12.
■ Specifications: Refer to page 15
. ■ Dimensions: Refer to page 18.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■ Accessories: Refer to pages 13 to 15.
5
A3P
Ordering Information
Ordering as a Set..................................The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Not all combinations are possible. Ask your OMRON representative for details.)
(1)
(Horizontal 2-split Screen)
(Horizontal 2-split Screen)
Square
Models
(2)
A3PA
Standard Loads
Contact type
Operation
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Momentary operation (Self-resetting) Alternate operation (Self-holding)
Pushbutton
color symbol
Case color
Black
Light gray
Black
Light gray
Output
SPDT
Lighting
LED
24 VDC
6 VDC/VAC
A3PA-90A21-24E(1)(2) A3PA-90A22-24E(1)(2) A3PA-90B21-24E(1)(2) A3PA-90B22-24E(1)(2) R O G W
A3PA-90A21-06
A3PA-90A21-14
A3PA-90A21-28
A3PA-90C21-24E(1)(2)
A3PA-90C21-06
A3PA-90C21-14
A3PA-90C21-28
A3PA-90A22-06
A3PA-90A22-14
A3PA-90A22-28
A3PA-90B21-06
A3PA-90B21-14
A3PA-90B21-28
A3PA-90B22-06
A3PA-90B22-14
A3PA-90B22-28
Incandescent lamp 14 VDC/VAC
28 VDC/VAC
*
LED
24 VDC
A3PA-90C22-24E(1)(2) A3PA-90D21-24E(1)(2) A3PA-90D22-24E(1)(2) R O G W
6 VDC/VAC
A3PA-90C22-06
A3PA-90C22-14
A3PA-90C22-28
A3PA-90D21-06
A3PA-90D21-14
A3PA-90D21-28
A3PA-90D22-06
A3PA-90D22-14
A3PA-90D22-28
DPDT
Incandescent lamp 14 VDC/VAC
28 VDC/VAC
*
Note: Enter the desired color symbols for the Pushbutton in (1) and (2). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example:
Red
White Lower
Upper A3PA-90D21-24E R W
Red White
*Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use
the appropriate combination.
(1)
(Horizontal 2-split Screen)
(Horizontal 2-split Screen)
Square
Models
(2)
A3PA
Microloads
Contact type Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A)
Operation
Momentary operation (Self-resetting)
Black Light gray
A3PA-90E21-24E(1)(2) A3PA-90E22-24E(1)(2)
Pushbutton
color symbol
Case color
Output
SPDT
Lighting
LED
24 VDC
6 VDC/VAC
R O G W
A3PA-90E21-06
A3PA-90E21-14
A3PA-90E21-28
A3PA-90E22-06
A3PA-90E22-14
A3PA-90E22-28
Incandescent lamp 14 VDC/VAC
28 VDC/VAC
*
LED
24 VDC
A3PA-90G21-24E(1)(2) A3PA-90G22-24E(1)(2)
R O G W
*
6 VDC/VAC
A3PA-90G21-06
A3PA-90G21-14
A3PA-90G21-28
A3PA-90G22-06
A3PA-90G22-14
A3PA-90G22-28
DPDT
Incandescent lamp 14 VDC/VAC
28 VDC/VAC
Note: Enter the desired color symbols for the Pushbutton in (1) and (2). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example:
Red
White Lower
Upper A3PA-90D21-24E R W
Red White
*Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use
the appropriate combination.
Individual models: Refer to pages 9 to 12.
■ Specifications: Refer to page 15
. ■ Dimensions: Refer to page 18.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■ Accessories: Refer to pages 13 to 15.
6
A3P
Ordering Information
Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Single Screen)
(Single Screen)
(1)
Round
A3PT
Standard Loads
Contact type
Operation
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Momentary operation
(Self-resetting)
Alternate operation
(Self-holding)
Pushbutton
color symbol
Case color
Light gray
Light gray
Output
SPDT
Lighting
LED
24 VDC
6 VDC/VAC
A3PT-90A12-24C(1)
A3PT-90A12-06
A3PT-90A12-14
A3PT-90A12-28
A3PT-90C12-24C(1)
A3PT-90C12-06
A3PT-90C12-14
A3PT-90C12-28
A3PT-90B12-24C(1)
A3PT-90B12-06
---
R O G W
Incandescent lamp 14 VDC/VAC
28 VDC/VAC
*
A3PT-90B12-28
A3PT-90D12-24C(1)
A3PT-90D12-06
A3PT-90D12-14
A3PT-90D12-28
LED
24 VDC
R O G W
*
6 VDC/VAC
DPDT
Incandescent lamp 14 VDC/VAC
28 VDC/VAC
Note: Enter the desired color symbols for the Pushbutton in (1) and (2). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PT-90A12-24C R
* Incandescent lamps are supplied with a colored plates (white, red, green, blue, and orange). Use the appropriate combination. Models A3PT (round models), however,
are not supplied with legend plates.
(Single Screen)
(Single Screen)
(1)
Round
A3PT
Microloads
Microload
(125 VAC, 0.1 A; 30 VDC, 0.1 A)
Contact type
Operation
Momentary operation
(Self-resetting)
Pushbutton
color symbol
Case color
Light gray
Output
Lighting
LED
24 VDC
A3PT-90E12-24C(1)
A3PT-90E12-28
R O G W
SPDT
Incandescent lamp 28 VDC/VAC
LED 24 VDC
Incandescent lamp 28 VDC/VAC
*
G W
*
A3PT-90G12-24C(1)
A3PT-90G12-28
DPDT
Note: Enter the desired color symbols for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PT-90E12-24C R
* Incandescent lamps are supplied with a colored plates (white, red, green, blue, and orange). Use the appropriate combination. Models A3PT (round models), however,
are not supplied with legend plates.
Individual models: Refer to pages 9 to 12.
■ Specifications: Refer to page 15
. ■ Dimensions: Refer to page 18.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■ Accessories: Refer to pages 13 to 15.
7
A3P
Ordering Information
Illumination-only and Colored-illumination LED Models
“Illumination only” describes LED models for which the screen color is the same whether the LED is lit or not. The screen simply becomes brighter
when the LED lights.
Example: Red LED
Not lit
Cap (transparent)
Red
Lit
Red
Legend plate (transparent)
Colored plate (red)
Pushbutton
(Display)
Lamp
holder
LED lamp (red) - - - Lamp
“Colored illumination” describes LED models for which the screen color is white when the LED is not lit and changes to the color of the LED lamp
when the LED is lit.
Example: Red LED
Not lit
White
Cap (transparent)
Lit
Legend plate (transparent)
Red
Pushbutton
(Display)
Colored plate (white)
Lamp
holder
LED lamp (red) - - - Lamp
Ordering: With colored-illumination models, order the Pushbutton, Lamp, and Switch as shown in the following table.
Pushbutton
Lamp
Switch
Select the LED lamp-lighted model required
Select the LED lamps to suit your desired col-
from the selection on page 10. Each assembly oration from the selection on page 12. Number
includes the number of white colored plates re- of necessary LED lamps (standard)
quired to enable colored illumination for the
A3PJ (rectangular): 4
Select from the Switches on page 12.
corresponding screen-split configuration. For A3PA (square): 2
example, 4-split screen models include 4 white A3PT (round): 2
colored plates.
8
A3P
Ordering Information
Ordering Individually ............... Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
LED-lighted/Chameleon Models
LED Lamp-lighted Models
Incandescent Lamp-lighted Models
(LED is built into the Pushbutton.)
(LED lamp and Pushbutton are separate.)
(Incandescent lamp and Pushbutton are separate.)
Pushbutton
Pushbutton
Pushbutton
Round (A3PT) models not available.
· For Pushbutton Switch
· For Pushbutton Switch
· For Pushbutton Switch
A3P@-5@@@-@@E
A3P@-502@
A3P@-501@
Lamp (LED Lamp)*1
Lamp (Incandescent Lamp)*2
· Standard lamp
SLL-@@
· Low-power lamp
SLL-@@H
SLL-@@E@
Switch *
Switch *
Switch *
Round (A3PT) models not available.
· For Pushbutton Switch
A3P@-7@@@-@
· For Pushbutton Switch
A3P@-7@@@-@
· For Pushbutton Switch
A3P@-7@@@-@
* The Switch is compatible with LED-lighted models, LED lamp-lighted models, and incandescent lamp-lighted models.
*1. Number of necessary LED lamps.
*2. Number of necessary incandescent lamps.
Screen pattern
Single screen
A3PJ
A3PA
A3PT
Screen pattern
Single screen
A3PJ
A3PA
A3PT
2
2
2
2
1
2
2
Horizontal 2-split screen
Vertical 2-split screen
---
Horizontal 2-split screen
Vertical 2-split screen
---
4
4
(low-power
incandes-
cent lamp)
Vertical 3-split screen
Horizontal 3-split screen
Vertical 3-split screen
Horizontal 3-split screen
4-split screen
4-split screen
Ordering set combinations: Refer to page 3 to 7.
■ Specifications: Refer to page 15. ■ Dimensions: Refer to page 18.
■ Accessories: Refer to pages 13 to 15.
9
A3P
Ordering Information
Ordering Individually................Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
Pushbutton
LED-lighted Models (LED is built-in.)
Split-screen color
(color symbol)
Selection precau-
tions
Appearance
White (W)
A3PJ-5701
Red (R)
Green (G)
A3PJ-5703
Orange (O)
A3PJ-5706
A3PJ-5702
@@E
A3PJ-5712
@@E
A3PJ-5722
@@E
A3PJ-5732
@@E
A3PJ-5742
@@E
A3PA-5702
@@E
A3PA-5712
@@E
A3PA-5722
@@E
A3PA-5732
@@E
A3PA-5742
@@E
Single screen
-
@@E
A3PJ-5711
@@E
A3PJ-5721
@@E
A3PJ-5731
@@E
A3PJ-5741
@@E
A3PA-5701
@@E
A3PA-5711
@@E
A3PA-5721
@@E
A3PA-5731
@@E
A3PA-5741
@@E
-
-
@@E
A3PJ-5713
@@E
A3PJ-5723
@@E
A3PJ-5733
@@E
A3PJ-5743
@@E
A3PA-5703
@@E
A3PA-5713
@@E
A3PA-5723
@@E
A3PA-5733
@@E
A3PA-5743
@@E
-
@@E
A3PJ-5716
@@E
A3PJ-5726
@@E
A3PJ-5736
@@E
A3PJ-5746
@@E
A3PA-5706
@@E
A3PA-5716
@@E
A3PA-5726
@@E
A3PA-5736
@@E
A3PA-5746
@@E
• Enter the voltage to
be used in the@@at
the end of the mod-
el number.
Rectangular
models
White
Red
-
-
-
-
-
-
-
-
Horizontal
Examples of voltag-
es used:
2-split screen
Green
Orange
-
-
-
-
5V=@0 @5 E
12V=@1 @2 E
-
-
-
-
24V=@2 @4 E
Horizontal 2-split
screen models sup-
port only 24V.
• For the color of the
shaded part, select
the model accord-
ing to the colors
given at the top of
the table.
Single screen
-
-
-
-
White
Red
Green
Orange
Square models
-
-
-
-
-
-
-
-
Horizontal
2-split screen
-
-
-
-
-
-
-
-
Note: 1. A cap, legend plate (transparent), colored plate, white plunger case, and LED (with a current-limiting resistor) are built into the standard lighting unit.
2. Split-screen coloring configurations are given with the OMRON mark on the Switch facing down.
3. The LED is built-in and cannot be replaced individually.
LED Lamp-lighted Models (LED is not built-in.)
Rectangular models
Square models
Round models
Appearance
Selection precautions
Screen pattern
Screen
Model
Screen
Model
Screen
Model
• Parts included:
Colored plates (white, red, green, and or-
ange), a legend plate (transparent), and a
light baffle (split-screen models only) are in-
cluded. Use the appropriate combination for
the LED coloring required.
• The number of white colored plates required
to enable colored illumination for the corre-
sponding screen-split configuration is includ-
ed. (For example, 4-split screen models
include 4 white colored plates).
Single screen
A3PJ-5021
A3PA-5021
A3PA-5022
A3PT-5021
Horizontal
2- split screen
A3PJ-5022
A3PJ-5023
A3PJ-5024
A3PJ-5025
---
Vertical 2-split
screen
---
---
---
---
• The number of colored plates included for each
model are shown in the following table.
Screen pattern
White Red
Green Orange
Horizontal3-split
screen
---
---
1
2
1
1
1
1
1
1
Single screen
Horizontal 2-
split screens
Vertical 2-split
screens
Vertical 3-split
screen
Horizontal 3-
split screens
Vertical 3-split
screens
3
4
2
1
2
1
2
1
4-split screen
A3PJ-5026
---
---
4-split screen
Ordering set combinations: Refer to page 3 to 7.
■ Specifications: Refer to page 15
. ■ Dimensions: Refer to page 18.
■ Accessories: Refer to pages 13 to 15.
10
A3P
Ordering Information
Ordering Individually ............... Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
Pushbutton
Incandescent Lamp-lighted Models (Incandescent lamp is not built-in.)
Rectangular models Square models
Round models
Appearance
Selection precautions
Screen pattern Screen
Model
Screen
Model
Screen
Model
• Parts included:
Colored plates (white, red, green, orange, and
blue), legend plates (transparent and milk white),
and a light baffle (split-screen models only) are
supplied.
Single screen
A3PJ-5011
A3PA-5011
A3PT-5011 *
Horizontal 2-
split screen
A3PJ-5012
A3PJ-5013
A3PJ-5014
A3PJ-5015
A3PA-5012
---
---
---
---
* A3PT (round) models do not contain a legend plate.
• The number of colored plates included is shown in
the following table.
Vertical 2-split
screen
---
---
---
Screen pattern White Red Green Orange Blue
Single screen
1
1
1
1
1
1
1
1
1
1
Horizontal3-split
screen
Horizontal 2-
split screens
Vertical 2-split
screens
Vertical 3-split
screen
Horizontal 3-
split screens
Vertical 3-split
screens
2
2
2
2
2
2
2
2
2
2
4-split screen
A3PJ-5016
---
---
4-split screen
Chameleon Models (with Built-in LED)
Chameleon pushbutton
switch
Appearance
Rated voltage
Rectangular
12 VDC
A3PJ-5800-12E
A3PJ-5800-24E
A3PA-5800-12E
A3PA-5800-24E
24 VDC
12 VDC
24 VDC
Square
Note: 1. With chameleon models the whole screen lights red, green, or orange
(i.e., red and green simultaneously).
2. A cap, legend plate (transparent), white colored plate, and LED (with a
current-limiting resistor) are built into the Pushbutton.
Ordering set combinations: Refer to page 3 to 7.
■ Specifications: Refer to page 15
. ■ Dimensions: Refer to page 18.
■ Accessories: Refer to pages 13 to 15.
11
A3P
Ordering Information
Ordering Individually..........................Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available
as sets can be created using individual Units. Also, store the parts as spares for maintenance and
repairs.
Pushbutton (For information on mounting, refer to page 25.)
LED Lamp
Voltage
5 VDC
12 VDC
24 VDC
Applicable cap (color)
(colored plate)
Selection precautions
Color
Model (DC only) Model (DC only) Model (DC only)
Red
SLL-05ER
SLL-05EY
SLL-05EG
SLL-05EW
SLL-12ER
SLL-12EY
SLL-12EG
SLL-12EW
SLL-24ER
SLL-24EY
SLL-24EG
SLL-24EW
Red
Orange
Green
White
In the standard setup, 4 LED lamps are used
with A3PJ models and 2 LED lamps are
used with A3PA and A3PT models.
Yellow
Green
White
Incandescent Lamp
Lamp type
Standard lamp
Low-power lamp
Selection precautions
Voltage
• In the standard setup for A3PJ models, 2 lamps are used with sin-
gle screen models, and 4 lamps are used with split-screen models.
If 3 or 4 lamps are lit continuously, use low-power lamps.
• In the standard setup for A3PA models, 1 lamp is used with single
screen models, and 2 lamps are used with split-screen models.
• In the standard setup for A3PT models, 2 lamps are used.
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
SLL-06
SLL-14
SLL-28
SLL-06H
SLL-14H
SLL-28H
Switch (common to both incandescent lamp-lighted models and LED models)
Rectangular models Square models Round models
Appearance
Selection precautions
Switch
Number of
outputs
Contact
type
Model
Model
Model
Operation
• The end digit denotes the
color of the flange: -1
denotes a black flange,
and -2 denotes a light
gray flange. Round
switches are available
only in light gray, and not
in black.
• Use the Switch in combi-
nation with the same
shape Lamp (rectangu-
lar, square or round).
Example:Forrectangular
Lamp A3PJ-5011, select
Switch A3PJ-7@@0-@.
On the Switch itself, how-
ever, only 3 digits are
shown, as follows:
Momentary operation
Alternate operation
Momentary operation
Alternate operation
Momentary operation
Alternate operation
Momentary operation
Alternate operation
Momentary operation
Alternate operation
Momentary operation
Alternate operation
A3PJ-7010-1
A3PJ-7020-1
A3PJ-7030-1
A3PJ-7040-1
A3PJ-7150-1
A3PJ-7160-1
A3PJ-7050-1
A3PJ-7060-1
A3PJ-7070-1
A3PJ-7080-1
A3PJ-7170-1
A3PJ-7180-1
A3PA-7010-1
A3PA-7020-1
A3PA-7030-1
A3PA-7040-1
---
A3PT-7010-2
A3PT-7020-2
A3PT-7030-2
A3PT-7040-2
---
1
2
3
1
2
3
Silver alloy
contact
---
---
A3PA-7050-1
A3PA-7060-1
A3PA-7070-1
A3PA-7080-1
---
A3PT-7050-2
A3PT-7060-2
A3PT-7070-2
A3PT-7080-2
---
Gold alloy
contact
A3PJ-7@@.
• Momentary operation is
self-resetting, and alter-
nate operation is self-
holding (i.e., push-on,
push-off).
---
---
Ordering set combinations: Refer to page 3 to 7.
■ Specifications: Refer to page 15
. ■ Dimensions: Refer to page 18.
■ Accessories: Refer to pages 13 to 15.
12
A3P
Ordering Information
Accessories, Replacements, and Tools
Accessories
Name
Appearance
Classification
Rectangular
A3PJ-4101
Square
Application precautions
Wire-wrap terminal
A3PA-4101
• The Socket cannot be used
with when mounting multi-
ple Switches or with 3C
models.
Socket
PCB terminal
A3PJ-4102
A3PJ-4103
A3PJ-4001
A3PA-4102
A3PA-4103
A3PA-4001
Solder terminal
Short edge
barrier (Hori-
zontal mount-
ing) (1 pair)
Black
• The purpose of the barrier
is to prevent malfunction-
ing and to improve design
image of the mounting
panel.
• Intermediate barrier × 1.
• Edge barriers × 1 pair (2
Units).
• Mount short barriers hori-
zontally.
• Mount long barriers verti-
cally.
Light gray
Black
A3PJ-4002
A3PJ-4004
A3PA-4002
Long edge
barrier (Verti-
cal mounting)
(1 pair)
---
Light gray
A3PJ-4005
Barrier
Short inter-
mediate barri-
er (Horizontal
mounting)
Black
Light gray
Black
A3PJ-4007
A3PJ-4008
A3PJ-4010
A3PJ-4011
A3PA-4007
A3PA-4008
• For details on mounting, re-
fer to page 25.
Long interme-
diate barrier
(Vertical
---
Light gray
mounting)
• Can be used by exchang-
ing with the cap.
• Cannot be used with seal
cover.
For horizontal mounting (with
OMRON logo facing down)
A3PJN-5050
A3PJN-5055
A3PAN-5050
• Can be used with barrier.
• Use horizontal mounting
guard for consecutive hori-
zontal mounting, and use
vertical mounting guard for
consecutive vertical
mounting.
• Cannot be used with barrier
and/or switch guard.
• For details on mounting, re-
fer to page 25.
Switch guard
For vertical mounting (with
OMRON logo facing to the
right)
A3PAN-5055
A3PA-5060
Seal cover
---
---
A3PJ-5060
A3PJ-3002
• Cap is manufactured from
vinyl chloride.
• Use when vertically mount-
ing individual (with barrier)
or multiple Switches (in
standard mounting style
and with barrier). Since a
short mounting plate is at-
tached to the Switch, re-
place it with the long one.
Longmounting
plate
---
13
A3P
Ordering Information
Accessories
Name
Appearances
Classification
White
A3PJ
A3PA
A3PA-5101
A3PA-5102
A3PA-5103
A3PA-5104
A3PA-5105
A3PA-5106
A3PA-5121
A3PA-5122
A3PA-5123
A3PA-5124
A3PA-5125
Application precautions
A3PJ-5101
A3PJ-5102
A3PJ-5103
A3PJ-5104
A3PJ-5105
A3PJ-5106
A3PJ-5121
A3PJ-5122
A3PJ-5123
A3PJ-5124
A3PJ-5125
A3PJ-5126
A3PJ-5131
A3PJ-5132
A3PJ-5133
A3PJ-5134
---
Red
Green
Blue
Single screen
Yellow
Orange
White
Red
Green
Blue
Horizontal 2-
split screen
• Keep mounted at all times.
• Contact your OMRON repre-
sentative for color changes
or other specifications.
• For details on mounting, refer
to page 25.
Yellow
Orange
White
Red
Green
Blue
Colored plate
for incandes-
cent lamp
A3PA-5126
---
---
---
---
---
---
---
---
---
---
---
---
Vertical 2-split
screen
Yellow
Orange
White
Red
Green
Blue
Yellow
Orange
White
Red
A3PJ-5136
A3PJ-5161
A3PJ-5162
A3PJ-5163
---
4-split screen
Single screen
A3PJ-5165
A3PJ-5166
A3PJ-5301
A3PJ-5302
A3PJ-5303
A3PJ-5305
A3PJ-5306
A3PJ-5321
A3PJ-5322
A3PJ-5323
A3PJ-5325
A3PJ-5326
A3PJ-5331
A3PJ-5332
A3PJ-5333
A3PJ-5335
A3PJ-5336
A3PJ-5361
A3PJ-5362
A3PJ-5363
A3PJ-5365
A3PJ-5366
A3PJ-4302
A3PJ-4303
A3PJ-4304
A3PJ-4305
A3PJ-4306
A3PJ-4307
A3PJ-4304
A3PJ-4308
A3PA-5301
A3PA-5302
A3PA-5303
A3PA-5305
A3PA-5306
A3PA-5321
A3PA-5322
A3PA-5323
Green
Yellow
Orange
White
Red
Horizontal 2-
split screen
• Keep mounted at all times.
If the colored plate is lost or
damaged, contact OMRON.
• Use in accordance with color-
ing of the built-in LED.
• For details on mounting, refer
to page 25.
Green
Yellow
Orange
White
Red
A3PA-5325
A3PA-5326
Colored plate
for LED
---
---
---
---
---
---
---
---
Vertical 2-split
screen
Green
Yellow
Orange
White
Red
4-split screen
Green
Yellow
Orange
---
---
Horizontal 2-split screen
Vertical 2-split screen
A3PA-4302
---
---
---
---
---
---
---
• Keep mounted at all times.
If the light baffle is lost, con-
tact OMRON.
• Used in LED lamp-lighted
models. Cannot be used in
LED-lighted models.
Long axis
Horizontal 3-
split screen
Short axis
Long axis
Short axis
Long axis
Short axis
Light baffle
Vertical 3-split
screen
4-split screen
Transparent legend plate
Milk-white legend plate
A3PJ-5202
A3PJ-5201
A3PA-5202
A3PA-5201
• A transparent legend plate is
mounted on the Pushbutton.
Legend plate
Cap
Transparent cap
A3PJ-5600
A3PA-5600
---
• The surface is crimp-pro-
cessed, so there is no reflec-
tion.
Crimp-processed transpar-
ent cap
A3PJ-5600-A
A3PA-5600-A
14
A3P
Ordering Information
Tools
Name
Appearance
Classification
Model
Application precautions
• Use to extract components when
replacing the Pushbutton.
Extractor
---
A3PJ-5080
Specifications
Approved Standard Ratings
UL (File No. E41515), CSA (File No. LR45258)
Ratings
Contact Ratings
Standard Load:
Microload:
5 A at 125 VAC
3 A at 250 VAC
0.1 A at 125 VAC
0.1 A at 30 VDC
Silver Alloy Contacts (for Standard Loads)
Non-inductive load (A)
Resistive load Lamp load
NC NO NC NO
0.7
Inductive load (A)
Inductive load Motor load
NC NO NC NO
1.3
Rated
voltage
(V)
Note: Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received
certification, consult your supplier.
125 VAC
250 VAC
5
3
3
2
0.5
0.8
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5
5
4
0.4
0.2
2
2
2
0.05
0.03
4
4
3
0.4
0.2
3
3
3
0.05
0.03
CCC (GB14048.5)
Standard Load:
3 A at 250 VAC
4 A at 30 VDC
Microload:
0.1 A at 125 VAC
0.1 A at 30 VDC
Note: 1. The above values are for steady-state currents.
2. Inductive load: Power factor = 0.4; time constant = 7 ms.
3. The lamp load has an inrush current of 10 times the steady-state current.
4. The motor load has an inrush current of 6 times the steady-state current.
Standard testing condition
(1) Ambient temperature: 20 2°C
(2) Ambient humidity: 65 5%RH
(3) Operating frequency: 20 times/min.
Gold Alloy Contacts (for Microloads)
0.1 A at 30 VDC (resistive load);
Rated voltage (V)
0.1 A at 125 VAC (resistive load)
Minimum applicable load 1 mA at 5 VDC
LED and Incandescent Lamp Ratings
LED for LED-lighted Models
Characteristics
Mechanical
Electrical
120 operations/minute max. *1
30 operations/minute max.
100 MΩ min. (at 500 VDC)
Operating frequency
Model
A3PJ/M2PJ
A3PA/M2PA
Insulation resistance
Rated current
Rated current
Between terminals of same polarity
Between terminals of different polarity
1,000 VAC, 50/60 Hz for 1 minute *2
Applied
voltage
Rated
voltage
Single
2-split
screen
Single
2-split
screen
2,000 VAC, 50/60 Hz for 1 minute
screen
80 mA
40 mA
20 mA
screen
80 mA
40 mA
20 mA
Between current-carrying metal part and
ground
Dielectric
strength
2,000 VAC, 50/60 Hz for 1 minute
5 VDC 5%
5 VDC
---
---
---
---
12 VDC 5% 12 VDC
24 VDC 5% 24 VDC
Between each terminal and
non-current-carrying metal part
2,000 VAC, 50/60 Hz for 1 minute
15 mA × 2
13 mA × 2
Between lamp terminals
1,000 VAC, 50/60 Hz for 1 minute *3
10 to 55 Hz, 1.5 mm double amplitude
500 m/s2
Vibration resistance
Malfunction
Destruction
Malfunction
LED for Chameleon Models
Shock resistance
Rated current
200 m/s2
Applied voltage
Rated voltage
Green
Red
Momentary operation models:
1,000,000 operations min.
Alternate operation models:
200,000 operations min.
(One operation consists of set and
reset operations.)
12 VDC 5%
24 VDC 5%
12 VDC
24 VDC
26 mA
13 mA
20 mA
10 mA
Mechanical
Electrical
Life expectancy
Incandescent Lamp
100,000 operations min.
Approx. 30 g
Item
Standard lamp
Model
Low-power lamp
Weight
Applied voltage Rated voltage Rated current
Rated current
100 mA
40 mA
Model
SLL-06H
SLL-14H
SLL-28H
NC
NO
Silver contact: 10 A max.
Silver contact: 10 A max.
Inrush current
5 VDC
6 V
200 mA
80 mA
40 mA
SLL-06
SLL-14
SLL-28
12 VDC
24 VDC
14 V
28 V
LED-lighted models:
(with no icing or condensation)
Incandescent lamp-lighted models:
10 C to 50
−10°C to 40°C
25 mA
Ambient operating temperature
−
°
°C
LED Lamp (for LED Lamp-lighted Models)
(with no icing or condensation)
35% to 85%RH
−25°C to 65°C
IP40
Ambient operating humidity
Ambient storage temperature
Degree of protection
Electric shock protection class
PTI (proof tracking index)
Pollution degree
Type
Applied voltage Rated voltage Rated current
Model
5 VDC 5%
12 VDC 5%
24 VDC 5%
5 VDC
30 mA
15 mA
SLL-05E@
SLL-12E@
SLL-24E@
DC only
12 VDC
24 VDC
Class II
12.5 mA
175
3 (IEC947-5-1)
*1. With alternate operation models, 60 operations/minute max. One operation
cycle consists of set and reset operations.
*2. 600 VAC for microloads.
*3. With no incandescent lamp or LED lamp mounted.
15
A3P
Specifications
Operating Characteristics
Model
A3PJ series
A3PA series
A3PT series
Operating
Characteristics
Momentary
Alternate
Momentary
Alternate
Momentary
Alternate
operation models operation models operation models operation models operation models operation models
Operating force
Releasing force
Total travel
OF max.
RF min.
TT
5.88 N
0.39 N
6.86 N
0.29 N
5.88 N
0.39 N
6.86 N
0.29 N
3.92 N
0.39 N
4.90 N
0.29 N
Approx. 3.5 mm Approx. 3.5 mm Approx. 3.5 mm Approx. 3.5 mm Approx. 3.5 mm Approx. 3.5 mm
Pretravel
PT max.
3 mm
---
3 mm
3 mm
---
3 mm
3 mm
---
3 mm
Lock travel alternate LTA min.
0.5 mm
0.5 mm
0.5 mm
Nomenclature
Model Structure
Lighting
method
LED-lighted models
(LED is built-in.)
LED lamp-lighted models
(LED lamp is not built-in.)
Incandescent lamp-lighted models
(Incandescent lamp is not built-in.)
Models
A3PJ
A3PA
A3PJ
A3PA
A3PT
A3PJ
A3PA
A3PT
Single
screen
Single
screen
Single
screen
Single
screen
Single
screen
Vertical 3-split
screen
Single
screen
Vertical 3-split
screen
Single
screen
Single
screen
Horizontal 2-split
screen
Horizontal 2-split
screen
Horizontal 2-split
screen
Horizontal 2-split
screen
Horizontal 2-split Horizontal 3-split
Horizontal 2-split Horizontal 3-split
Screen
patterns
screen
screen
screen
screen
Chameleon
(3-color)
Chameleon
(3-color)
Vertical 2-split
screen
Vertical 2-split
screen
4-split screen
4-split screen
LED-lighted models
Incandescent lamp-lighted models
LED lamp-lighted models
Chameleon models (full screen
illumination in one of three colors)
LED-lighted models
Cap
(transparent)
Cap
(transparent)
Cap
(transparent)
Pushbutton
Legend plate *
(transparent)
(Split-screen models
contain a light
baffle.)
Legend plate
(transparent)
Legend plate
(transparent)
●Pushbutton colors
Colored
plate
· LED-lighted models and
LED lamp-lighted models
Colored
plate
Colored
plate
White, Red, Green, Orange
Lamp
holder
LED Unit
LED Unit
3-color emitter
·
Incandescent lamp-lighted model
Built-in LED
White, Red, Green, Blue,
Orange
* Incandescent lamp-lighted
A3PT models do not contain
a legend plate.
●
Switch Specifications
Standard load
Lamp
●Case Color
· 250 VAC, 3 A
Select either black or light
30 VDC, 4A
Microload
· 125 VAC, 0.1 A
30 VDC, 0.1 A
gray to suit your panel design.
(The round A3PT
models are available in
light gray only.)
Switch
Minimum applicable load: 5 VDC, 1 mA
16
A3P
Nomenclature
A3P Lighting Method Diagram
The following diagram shows
the Switches with the
mark facing down.
Single screen Horizontal 2-split
models screen models
LED-lighted
models
•
As a set: See page 3.
• Individually: See page 9.
Single screen Horizontal 2-split Vertical 2-split
models screen models screen models
LED
lamp-lighted
models
LED
models
• Individually: See page 9.
(Not available as a set.)
Vertical 3-split Horizontal 3-split 4-split screen
screen models screen models
A3PJ
(rectangular)
Single screen
models
Chameleon
models
•
•
As a set: See page 3.
Individually: See page 9.
(Full screen illumination
in one of three colors)
Single screen Horizontal 2-split Vertical 2-split
models
screen models screen models*
Incandescent lamplighted
models
•
•
As a set: See page 3.
Individually: See page 9.
*Models indicated with an asterisk are only
available individually.
Vertical 3-split Horizontal 3-split 4-split screen
screen models* screen models*
models*
Single screen Horizontal 2-split
models
screen models
•
•
As a set: See page 5.
Individually: See page 9.
LED-lighted
models
Single screen Horizontal 2-split
LED
models
screen models
•
Individually: See page 9.
(Not available as a set.)
LED
models
lamp-lighted
models
A3PA
(square)
Single screen
models
Chameleon
models
•
•
As a set: See page 5.
Individually: See page 9.
Single screen Horizontal 2-split
models
screen models
Incandescent lamplighted
models
•
•
As a set: See page 5.
Individually: See page 9.
Single screen
models
LED
lamp-lighted
models
LED
models
•
•
As a set: See page 7.
Individually: See page 9.
A3PT
(round)
Single screen
models
Incandescent lamplighted
models
•
•
As a set: See page 7.
Individually: See page 9.
17
A3P
Dimensions The Dimension shows 2-switch outputs.
(Unit: mm)
A3PJ (Rectangular) Models
A3PA (Square) Models
2.8
22
26.1
29.9 0.2
0.5
OMRON logo
#110 quick connect terminal/
solder terminal
#110 quick connect terminal/
solder terminal
OMRON logo
19.1 × 19.1
25 0.1
22.9 0.2
25 0.1
22.9 0.2
18.9
Separator
Separator
43.6
52 max.
52.6
6.7
25 0.1
43.6
6.7
32 0.1
52 max.
52.6
A3PT (Round) Models
#110 quick connect terminal/solder terminal
22.4 28.5 dia.
OMRON logo
24.9 dia.
32 dia.
23.8
6.4
43.6
52 max.
52.6
Note: The thickness of tab terminals #110 and solder terminals is 0.5 mm.
18
A3P
Dimensions
(Unit: mm)
Terminal connections
LED-lighted Models
(The terminal arrangement diagram shows a 1-switch output. Connections to terminals from the lighting block are the same for 2 outputs.)
Rated voltage
5 VDC
12 VDC
24 VDC
Screen
pattern
Model
Bottom view
Top view
Bottom view
Top view
Bottom view
Top view
Single screen
NO1
NC1
NO1
NC1
NO1
NC1
LC+
LC+
LC+
C1
C1
C1
Terminal
arrangement
Lighting block
Top view
Terminal
arrangement
Lighting block
Bottom view
Terminal
arrangement
Lighting block
A3PJ
Bottom view
Top view
Horizontal
2-split screen
NO1
L2
NO1
NC1
NC1
LC+
LC+
C1
C1
Terminal
Lighting block
Terminal
Lighting block
arrangement
arrangement
Bottom view Top view
Bottom view Top view
Bottom view Top view
Single screen
NO1
LC+
NO1
LC+
NO1
LC+
NC1
C1
NC1
C1
NC1
C1
Terminal
arrangement
Lighting block
Terminal
arrangement
Lighting block
Terminal
arrangement
Lighting block
A3PA
Bottom view Top view
Bottom view Top view
2-split screen
NO1
LC+
NC1
C1
NO1
LC+
NC1
C1
Terminal
Lighting block
Terminal
Lighting block
arrangement
arrangement
19
A3P
Dimensions
(Unit: mm)
Incandescent Lamp-lighted/LED Lamp-lighted Models
(All are shown with the OMRON logo facing down. The terminal arrangements are the same as for the LED-lighted models.)
Model
Rectangular A3PJ models
Square A3PA models
Round A3PT models
Type
Bottom view
Top view
Bottom view
Top view
Bottom view Top view
NO1
LC+
NO1
NC1
NO1
LC+
NC1
Silver/gold alloy
contacts
(1 output)
NC1
LC+
C1
C1
C1
Terminal
arrangement
Lighting block
Top view
Terminal
arrangement
Lighting block
Top view
Terminal
arrangement
Lighting block
Top view
Bottom view
Bottom view
Bottom view
NO1 NO2
NO1 NO2
NC1 NC2
Silver/gold alloy
contacts
(2 outputs)
NO1 NO2
LC+
LC+
NC1 NC2
NC1 NC2
C1 C2
LC+
C1
C2
C1 C2
Terminal
arrangement
Lighting block
Top view
Terminal
arrangement
Lighting block
Terminal
arrangement
Lighting block
Bottom view
NO1 NO2 NO3
NC1 NC2 NC3
Silver/gold alloy
contacts
(3 outputs)
---
---
C1 C2 C3
LC+
Terminal
Lighting block
arrangement
LED Chameleon Models
(The terminal arrangement diagram shows a 1-switch output. Connections to terminals from the lighting block are the same for 2 outputs.)
Rated voltage
24 VDC
Model
Rectangular
A3PJ model
L2−
L1−
NO1
NC1
L4−
LC+
C1
L3−
Square A3PA
model
NO1
LC+
NC1
L1−
L2−
C1
Terminal Arrangement and Coloring
Chameleon Models
LC+
L1−
LC+
L2−
Red
LC+
Wiring
L1− and L2−
shorted
Coloring
Green
Orange
20
A3P
Dimensions
(Unit: mm)
Panel Cutout (If using a Switch Guard or Seal Cover, refer to the panel cutout diagrams on page 23.)
A3PJ (Rectangular) Models
Classification
Mounting design
Panel cutout
Remarks
0.3
Individual
mounting
(Horizontal)
30.5
0.1
25
0.3
23.5
23.5
0.1
32
0.3
Multiple
mounting
(Horizontal)
32n−1.5
0.1
0.1
25
32
1
2
n
Panel cutout spacing between rows of Units:
0.3
0.5
32n
3 min.
Flange
mount
Mount to long
mounting plate
(A3PJ-3002)
before use.
0.3
23.5
models
Individual
mounting
(Vertical)
6 min.
0.3
30.5
30.5
0.1
25
Mount to long
mounting plate
(A3PJ-3002)
before use.
0.3
25n−1.5
Multiple
mounting
(Vertical)
0.1
32
1
2
n
0.3
0.5
25n
Individual
mounting
(Horizontal)
0.3
36.4
27
0.3
0.3
23.5
23.5
39
For barrier mount models, refer to Accessories on
page 13.
Multiple
mounting
(Horizontal)
0.3
32.9n+3.5
27
34
1
2
n
Panel cutout spacing between rows of Units:
(Dotted line indicates the position of each mounting
barrier.)
1
33n+6
Barrier
mount
models
Mount to long
mounting plate
(A3PJ-3002)
before use.
0.3
29.4
Individual
mounting
(Horizontal)
1.3
6 min.
0.3
30.5
30.5
6 min.
0.1
32
Mount to long
mounting plate
(A3PJ-3002)
before use.
0.3
25.9n+3.5
Multiple
mounting
(Vertical)
34
1
2
26n+6
n
0.3
1
Note: 1. n: Number of Units
2. Recommended panel thickness: 1 to 5 mm
3. Mount the panel before mounting the Switch Guard.
4. If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating.
A3PA (Square) Models
Classification
Mounting design
Panel cutout
Remarks
0.3
0.1
0.1
Panel cutout spacing between rows of Units:
23.5
25
Individual
mounting
3 min.
Flange
mount
models
0.3
0.1
22.5
25
6 min.
0.3
0.3
Multiple
mounting
25
27
27
23.5
23.5
1
2
n
0.3
0.1
25n−2.5
25n
Panel cutout spacing between rows of Units:
(Dotted line indicates the position of each mounting barrier.)
Individual
mounting
Barrier
mount
models
0.3
32
1
27.8
1.3
6 min.
6 min.
Multiple
0.3
2
n
23.5
mounting
0.3
26n+2.5
1
26n+6.5
Note: 1. n: Number of Units
2. Recommended panel thickness: 1 to 5 mm
3. Mount the panel before mounting the Switch Guard.
4. If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating.
A3PT (Round) Models
6.4 dia.
+0.2
11.8R
−0
29 0.3 dia.
Note: 1. Recommended panel thickness: 1 to 5 mm
2. If the panel is to be finished (e.g., coated), make sure that the panel
meets the specified dimensions after the coating.
4 min.
21
A3P
Dimensions
(Unit: mm)
Accessory Mounting Dimensions
Legend Plate
Extractor
Rectangular Models
Square Models
A3PJ-5080
20
A3PJ-5201/-5202
A3PA-5201/-5202
2.5
2.5
5
25.1
17.2
10
15
16.9
17.2
50
0.3
Plate surface 1.2
1.5
2
25
1.5
Note: Made from stainless steel.
24
Socket-mounting Dimensions
Rectangular Models A3PJ (M2PJ)
Square Models A3PA (M2PA)
25.6
25.6
Wire-wrap Terminal
A3PJ-4101
Wire-wrap Terminal
A3PA-4101
18
18
24
31.8
1 × 1 Wire-wrap Terminal
1 × 1 Wire-wrap Terminal
22.8
22.8
61.6
0.8
18.5
61.6
0.8
18.5
PCB Terminal
A3PA-4102
25.6
18
25.6
PCB Terminal
A3PJ-4102
18
1.2
0.3
3
1.2
0.3
3
24
31.8
22.8
22.8
61.6
3.6
61.6
0.5
3.6
0.5
PCB Cutout
(bottom view)
1.5
PCB Cutout
(bottom view)
8.8
5.25
17.6
8.4
8.7
1.25
5.2
10.5
10.4
17.4
2.05
8.65
3.5
Nine, 1.5-dia. holes
7
Eleven, 1.5-dia. holes
6.15
10.2
20.45
7
11.65
25.6
18
25.6
18
Solder Terminal
A3PJ-4103
Solder Terminal
A3PA-4103
Terminal Hole
Dimensions
0.8
3.2
3
3
Terminal Hole
24
Dimensions
31.8
0.3
0.8
3.2
0.3
3
3
0.9R
0.6R
22.8
0.9R
0.6R
22.8
61.6
61.6
8.2
8.2
Note: PCB cutout dimensions show the switch mounted to the socket with the OMRON logo facing down.
22
A3P
Dimensions
(Unit: mm)
Switch and Guard Mounting Dimensions
Rectangular Models
Square Models
A3PJN-5050 (Horizontal Mounting)
A3PJN-5055 (Vertical Mounting)
A3PAN-5050 (Horizontal Mounting)
A3PAN-5055 (Vertical Mounting)
52.6
52 max.
43.6
52.6
52 max.
43.6
Spring
Guard
Spring
9.6
9.6
25 0.1
25.4
25 0.1
25.2
25 0.1
Switch Guard
(A3AN-5050)
32 0.1
Switch Guard
(A3PJN-5050)
OMRON logo
OMRON logo
19.1
26.2 0.2
Panel Cutouts
Individual Mounting
(Horizontal)
22.5 0.3
Multiple Mounting
(Horizontal)
Panel Cutouts
Individual Mounting
(Horizontal)
Multiple Mounting
(Horizontal)
0.3
25n-2.5
0.3
32n-1.5
30.5 0.3
23.5 0.3
23.5 0.3
23.5 0.3
23.5 0.3
n = Number of mountings
n = Number of mountings
Note: Multiple vertical mounting is not possible.
Note: Multiple vertical mounting is not possible.
Seal Cover Mounting Dimensions
Cover A (transparent) Cover B (black)
Rectangular Models
A3PJ-5060
Square Models
Cover A (transparent) Cover B (black)
A3PA-5060
OMRON logo
Seal Cover
(A3PJ-5060)
OMRON logo
Seal cover
(A3PA-5060)
32.5
32.5
39.5
9.3
42.9
32.5
8.7
42.9
51.3 max.
51.9
51.3 max.
51.9
Panel Cutouts
Individual Mounting
(Horizontal)
Multiple Mounting
(Horizontal)
Panel Cutouts
Individual Mounting
Multiple Mounting
9.5 min.
0.3
10.5 min.
22.5
30.5 0.3
0.3
22.5
0.3
30.5
23.5 0.3
23.5 0.3
23.5 0.3
23.5 0.3
9.5 min.
9.5 min.
Note: 1. Recommended panel thickness: 1 to 5 mm
2. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.
23
A3P
Safety Precautions
Refer to Safety Precautions for all Pushbutton Switches.
Caution
Do not apply a voltage higher than the maximum
rated operating voltage between the lamp
terminals, as there is a risk that the incandescent
lamp or LED will be damaged, and the Pushbutton
will be ejected.
Using Microloads
• Using a standard load switch when a microload circuit is opened or
closed may cause contact failure on the contacts. Use the switch
within the operating range. (Refer to the diagram below.) Even
when using microload models within the operating range shown
below, if inrush current occurs when the contact is opened or
closed, it may cause the contact surface to become rough, and so
decrease life expectancy. Therefore, insert a contact protection
circuit where necessary. The minimum applicable load is the N-
level reference value. This value indicates the malfunction
reference level for the reliability level of 60% (λ 60) (conforming to
JIS C5003). The equation, λ 60 = 0.5 x 10−4/time indicates that the
estimated malfunction rate is less than 1/2,000,000 with a reliability
level of 60%.
When replacing the incandescent lamp, first turn
OFF the power supply, and then wait 10 minutes
before performing replacement, as the lamp is still
hot immediately after the power is turned OFF, so
there is a risk of burns.
Precautions for Correct Use
1. Always make sure that the power is turned OFF before mounting,
removing, or wiring the Switch, or performing maintenance.
Electric shock or fire may occur.
2. After wiring the Switch, make sure that there is a suitable isolation
distance.
Wiring
100 mA
26 mA
0.15 mA
30
24
• Solder quickly and correctly at 350°C max and for 3 s or less.
Wait for one minute after soldering before exerting any external
force on the solder.
Standard
load area
Microload
area
Operating Environment
12
Invalid
area
• Do not use in locations that are subject to dust, oil, or metal filings
as these may penetrate the interior of the Switch and cause
malfunction.
5
0
1 mA
1
100 mA 150 mA
LED (for VDC)
0.1
10
100
1,000
• Check the terminal polarity when wiring.
• The rated voltage is shown on the plate on the back of the lighting
unit, so be sure to use within the voltage shown.
• An LED current-limiting resistor is built in, so there is no need to
mount an external resistor.
Current (mA)
Others
• If the panel is to be finished (e.g., coated), make sure that the panel
meets the specified dimensions after the coating.
Incandescent Lamp
• Apply 80% of the rated voltage (operating voltage) to the
incandescent lamp to improve life expectancy and incandescence.
Character Plate (Character Film)
• If preparing the character plate separately, use a heat-resistant film
with a thickness of 0.1 to 0.3 mm.
24.1+0
17.1+0
−0.1
−0.3
17.1+0
17.1+0
−0.3
−0.3
24.8 +−00.3dia.
23. 0.1dia.
5.2+0
−0.3
24
A3P
Assembly/Disassembly
A3PJ/M2PJ (Rectangular Models), A3PA/M2PA (Square Models)
Locking/Unlocking Positive Cap Lock Mechanism
Mounting and Replacing LED and Incandescent Lamps
If using an A3PA (square) model with one incandescent lamp, insert
the lamp in the center hole.
Unlock
Lock
Positive cap stopper
Mounting Pushbutton
• Be sure to mount the Pushbutton with the correct orientation. Align
the groove on the Pushbutton, the projections in the Switch, and the
LED contact piece before pushing the Pushbutton into the Switch.
• When dismounting the Pushbutton, use the Extractor (A3PJ-5080)
for easy dismounting.
Note: Built-in LEDs cannot be replaced.
LED Rated Voltage Display (LED Models Only)
The LED rated voltage is shown between the built-in resistors on the
back of the lighting unit. Use within a range of 5%.
OMRON logo
Groove
A3PJ
Rated
voltage display
A3PA
LED contact piece
Diagram shows A3PA model.
Removing/Mounting Cap
Insert the A3PA from the open side into the theft-prevention stopper.
Note: Display is on the back.
Mounting Switch onto Panel
• Individual Mounting
and Barrier Mounting
When mounting the Switch,
push it into the panel cutout
from the front of the
mounting panel by holding it
with the logo mark
• Multiple Barrier Mounting (A3PJ)
When mounting a number of Switches in
line on the panel, link the Switches with
spacing barriers in between, attach
mounting barriers at both sides of this block
of Switches and, pushing in on the
mounting barriers at the side, insert the
Switches into the panel cutout together.
Mounting Colored Plate
Place the colored plate on the plunger case with the dull side of the
colored plate facing downward.
With A3PJ split-screen models, be sure that the projections on the
upper surface of the colored plate face outward. For the A3PA, make
sure that the flat plate is facing upwards.
“OMRON” facing downward.
Flat plate
Projection
OMRON
logo
OMRON
logo
A3PA
A3PJ
Mounting Barriers
Mount each part by pushing it in the direction of the arrow shown in
the corresponding illustration below.
Barrier mounting
Mounting Character Plate (Character Frame) and Legend
Plate
Mount the legend plate for the A3PJ under the layered surfaces and
mount the cap, as shown below.
Transparent cap
Legend plate
(Character plate)
Colored plate
(Light baffle)
25
A3P
Mounting Seal Cover
After mounting the seal cover onto the flange of the Switch, push the
Switch into the panel cutout.
Inscribing the Legend Plate
• Inscribe the legend plate to a depth of 0.5 mm max.
• The legend plate is made from polycarbonate resin. To coat the
legend plate, use an alcohol-based coating such as melamine,
phthalic acid, or acrylic.
Maintenance Lock
1. First, when you insert the transparent lens while pressing the
center, the maintenance lock mechanism will be activated, and the
Switch will not operate. Lamp replacement and other maintenance
can be performed without turning OFF the power supply to devices
and equipment. Use an insertion force of 4 kg.
2. Next, when you remove your finger from the Switch, the lock will be
released.
3. The Switch will start to operate when the lighting unit is pressed the
second time.
26
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
·
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2011.5
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2011 All Right Reserved.
相关型号:
A3PA-90C11-24EW
Pushbutton Switch, DPDT, Momentary, Quick Connect/solder Terminal, Panel Mount
OMRON
A3PA-90C12-05EO
Pushbutton Switch, DPDT, Momentary, Quick Connect/solder Terminal, Panel Mount
OMRON
A3PA-90C12-05ER
Pushbutton Switch, DPDT, Momentary, 3A, 30VDC, Quick Connect/solder Terminal, Panel Mount
OMRON
A3PA-90C12-12EG
Pushbutton Switch, DPDT, Momentary, Quick Connect/solder Terminal, Panel Mount
OMRON
A3PA-90C12-12EO
Pushbutton Switch, DPDT, Momentary, Quick Connect/solder Terminal, Panel Mount
OMRON
A3PA-90C12-12ER
Pushbutton Switch, DPDT, Momentary, 3A, 30VDC, Quick Connect/solder Terminal, Panel Mount
OMRON
A3PA-90C12-12EW
Pushbutton Switch, DPDT, Momentary, Quick Connect/solder Terminal, Panel Mount
OMRON