New Product  
Remote Reset Rocker Switch  
A8GS  
Minimum size class in the industry Rocker switch with reset function  
• Zero standby power by Reset function.  
• High inrush-current durability.  
Conforming to TV-8 rating. (Inrush 117A)  
• Model variation for Micro loads.  
Model variation of micro load and high capacity combination. (DPST)  
It is able to operate micro load and high capacity load at the same time.  
• Contact gap of 3 mm minimum.  
• UL and cUL standard approved, Conforming to EN standards.  
• Model variation for 3.3VDC circuit.  
(Please refer the Precautions)  
RoHS Compliant  
Usage example  
Saving energy by cutting the standby power.  
Saving energy by preventing forgetting to turn OFF main power.  
Turning OFF main power by remote.  
Turning OFF main power of many equipments at the same time.  
*
There are 2 kinds of main models A8GS. (Delay OFF Function model and Remote Reset model) With regard to the models with Delay OFF Function, please refer to the other catalog.  
List of Models  
1. Reset function type  
SPST  
Contact Form  
Micro load contact terminal × 1  
Power contact terminal × 1  
1 to 2: Power contact terminal  
a, b: Micro load contact terminal  
+, -: Coil terminal  
+
+
+
1
2
1
2
Quantity  
per box  
a
b
-
-
-
Quick-connect terminals  
#187 (t=0.8)  
Terminals  
CT Connector  
Solder terminals  
Reset voltage  
No Marking  
5V model  
A8GS-S1105  
3.3V model  
A8GS-S1103  
5V model  
A8GS-P1185  
3.3V model  
A8GS-P1183  
5V model  
A8GS-P1115  
3.3V model  
A8GS-P1113  
A8GS-S1205  
A8GS-S1203  
A8GS-S1303  
A8GS-P1285  
A8GS-P1385  
A8GS-P1283  
A8GS-P1383  
A8GS-P1215  
A8GS-P1213  
A8GS-P1313  
Marking on caps  
50  
A8GS-S1305  
A8GS-P1315  
DPST  
Micro load contact terminal × 1 + Power contact terminal × 1  
Contact Form  
1 to 2: Power contact terminal  
a, b: Micro load contact terminal  
+, -: Coil terminal  
+
1
2
Quantity  
per box  
a
b
-
Micro load contact terminal : CT Connector  
Power contact terminal : Quick-connect  
terminals #187 (t=0.8)  
Micro load contact terminal : CT Connector  
Power contact terminal : Solder terminals  
Terminals  
Reset voltage  
No Marking  
5V model  
A8GS-C1185  
3.3V model  
A8GS-C1183  
5V model  
A8GS-C1115  
3.3V model  
A8GS-C1113  
A8GS-C1285  
A8GS-C1385  
A8GS-C1283  
A8GS-C1383  
A8GS-C1215  
A8GS-C1315  
A8GS-C1213  
A8GS-C1313  
Marking on caps  
50  
1
A8GS  
DPST  
Power contact terminal × 2  
Contact Form  
1 to 4: Power contact terminal  
+, -: Coil terminal  
+
1
2
Quantity  
per box  
3
4
-
Quick-connect terminals  
#187 (t=0.8)  
Terminals  
Solder terminals  
Reset voltage  
No Marking  
5V model  
A8GS-D1185  
3.3V model  
A8GS-D1183  
5V model  
A8GS-D1115  
3.3V model  
A8GS-D1113  
A8GS-D1285  
A8GS-D1385  
A8GS-D1283  
A8GS-D1215  
A8GS-D1315  
A8GS-D1213  
A8GS-D1313  
Marking on caps  
50  
A8GS-D1383  
Note: 1. [ V ] is shown at the end of model name for TV-8 approved models. (Example : A8GS-P1185V, A8GS-C1185V, A8GS-D1185V)  
Note: 2. TV-8 approved model is only for Power switch circuit.  
Note: 3. [ 3 ] is shown at the end of model name for reset voltage 3.3 VDC models. (Example : A8GS-P1183).  
[ 5 ] is shown at the end of model name for reset voltage 5 VDC models. (Example : A8GS-P1185).  
2. Without Reset function type  
SPST  
DPST  
Microloadcontact  
Power contact terminal × 1  
Power contact terminal × 2  
Contact Form  
1 to 4: Power contact terminal  
a, b: Micro load contact terminal  
terminal  
× 1  
1
2
1
2
4
Quantity  
per box  
a
b
3
Quick-connect  
terminals  
#187 (t=0.8)  
Quick-connect  
terminals  
#187 (t=0.8)  
Solder  
terminals  
Solder  
terminals  
Terminals  
CT Connector  
No Marking  
A8GS-S1100  
A8GS-S1200  
A8GS-P1180  
A8GS-P1110  
A8GS-P1210  
A8GS-D1180  
A8GS-D1110  
A8GS-D1210  
A8GS-P1280  
A8GS-P1380  
A8GS-D1280  
A8GS-D1380  
Marking on caps  
50  
A8GS-S1300  
A8GS-P1310  
A8GS-D1310  
DPST  
Micro load contact terminal × 1 + Power contact terminal × 1  
Contact Form  
1 to 2 Power contact terminal  
a, b: Micro load contact terminal  
1
2
Quantity  
per box  
a
b
Micro load contact terminal : CT Connector  
Power contact terminal : Quick-connect  
terminals #187 (t=0.8)  
Micro load contact terminal : CT Connector  
Power contact terminal : Solder terminals  
Terminals  
No Marking  
A8GS-C1180  
A8GS-C1110  
A8GS-C1210  
A8GS-C1280  
Marking on caps  
50  
A8GS-C1380  
A8GS-C1310  
Note: 4. These models are without reset function, it has same function with standard Rocker switch.  
Ratings  
Contact Ratings  
Rated current  
Rated voltage  
(Resistive load)  
125 VAC  
250 VAC  
5 VDC  
16 A  
10 A  
0.2 A  
Power contact terminal  
Micro load contact terminal  
Note: 1. The above ratings were tested under the following conditions:  
(1) Ambient temperature : 20 ± ±2 °C  
(2) Ambient humidity  
: 65 ± ±5 % RH  
(3) Switching frequency : 7 times/min  
Reset Coil Ratings  
Rated voltage,  
Operating  
voltage range  
Coil resistance  
(Coil temperature: 20 ± 2 °C)  
Model  
Rated usage cycle  
current  
Reset voltage : 5V model  
(A8GS-@@@@5)  
Reset voltage : 3.3V model  
ON: 50 to 100 ms  
OFF: Min 5 sec  
5VDC 455 mA  
4.5 to 5.5 VDC  
3.0 to 3.6 VDC  
11 Ω±± ±20 %  
ON: 50 to 100 ms  
OFF: Min 5 sec  
3.3VDC 300 mA  
11 Ω±± ±20 %  
(A8GS-@@@@3)  
Note: 1. Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle.  
Otherwise the performance of the coil may be deteriorated.  
Note: 2. In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMRON sales representative.  
2
A8GS  
Contact specifications  
Micro load contact  
Power contact  
Silver alloy  
3 mm  
Material  
Gold alloy  
3 mm  
Contact gap  
Minimum applicable  
load (Reference value) *  
3 VDC 1 mA  
5 VDC 200 mA  
* Please refer to ''Using Micro loads'' in ''Precautions''(P6) for more information on the minimum applicable load.  
Characteristics  
Mechanical  
Switch operation: 20 times/min max, Coil operation: 7 times/min max  
7 times/min max  
Permissible operating  
frequency  
Electrical  
Insulation resistance  
100 MΩ min (at 500 VDC with insulation tester)  
100 mΩ max (6 VDC to 8 V, 1 A Voltage drop method)  
Micro load contact terminal 100 mΩ max (6 VDC to 8 V, 0.1 A Voltage drop method)  
Power contact terminal  
Contact resistance  
(initial value)  
Between terminals of the  
AC2,000 V 50/60 Hz 1 min  
same polarity  
Between terminals of the  
AC2,000 V 50/60 Hz 1 min  
different polarity  
Dielectric strength  
Between each terminals of the  
AC4,000 V 50/60 Hz 1 min  
switch and terminals of coil  
Between each terminals of  
AC4,000 V 50/60 Hz 1 min  
switch and ground  
Vibration resistance * Malfunction  
10 to 55 Hz 1.5 mm double amplitude (Malfunction within 1 ms)  
300 m/s2 min (Malfunction within 1 ms)  
1000 m/s2 max  
Malfunction  
Shock resistance *  
Destruction  
Ambient operating temperature  
Ambient operating humidity  
10 to +55 °C (with no icing or condensation, 60 % RH max)  
90 %RH max (+5 to 35 °C with no icing or condensation)  
Switch operation: 30,000 operations min, Coil operation: 10,000 operations min  
Switch operation: 10,000 operations min  
117 A max.  
Mechanical  
Durability  
Electrical  
Inrush current  
Degree of protection  
Contact release time **  
IEC IP40  
100 ms max  
A8GS-Sxxxx: around 9 g  
A8GS-Pxxxx: around 10 g  
A8GS-Cxxxx: around 11 g  
A8GS-Dxxxx: around 12 g  
Weight  
Note: 1. Above specification values are initial values.  
*For the testing condition in individual specification, contact your OMRON sales representative.  
**Time from voltage applied to reset coil to actual contacts opening.  
Approved Safety Standards  
UL (UL61058-1)  
TÜV (EN61058-1)  
Approved safety  
TV-8  
Approved safety  
standards ratings  
TV-8  
standards ratings  
16 A 125 VAC  
10 A 250 VAC  
approved ratings *  
approved ratings *  
8/128 A 250 VAC  
0.2 A 5 VDC  
Power contact terminal  
Micro load contact terminal  
10 (4) A 250 VAC  
0.2 A 5 VDC  
Power contact terminal  
Micro load contact terminal  
TV-8  
Note: 1. Approved safety standard ratings for Signal Switch Circuit is only for 'A8GS-Cxxxx' model. 'A8GS-Sxxxx' model is not approved.  
*These ratings are only for TV-8 rating approved models.  
Connector for Signal Switch Circuit and Coil Circuit  
CT connectors produced by Tyco Electronics Corporation or XR connectors produced by JST shall be used  
for connection of Signal and Coil circuit. Other connectors shall not be used.  
Tyco Electronics Corporation: CT connecter  
Pressure welding type  
JST: XR Connector  
AWG #28-26  
Cramping type  
Connector  
Terminal no.  
Connection with  
Switch  
Contact  
Housing  
179228-3  
179228-2  
AWG #30-26  
AWG #26-22  
AWG #28-26  
AWG #24  
1
2
3
1
2
a (Switch COM)  
---  
Micro load  
contact terminal  
173977-3  
173977-2  
2-179694-3  
03XR-6@-P*  
b (Switch NO)  
+ (Coil)  
179609-1  
179227-1  
Coil terminal  
2-179694-2  
02XR-6@-P*  
- (Coil)  
*
@ indicates Housing color.  
3
A8GS  
Operation  
Remote Reset Function  
Button is operated for turning OFF of Power and Micro load contact terminal by applying external signal to coil.  
Manual Operation  
Power and Micro load contact terminal are operated to turn ON/OFF by manual, same as standard Rocker switch.  
OFF  
(1) Manual ON  
(2) Manual OFF  
Button operating  
condition  
Power / Micro load  
contact terminal  
OFF  
ON  
OFF  
Remote Reset Function Operation  
It is able to turn OFF Power and Micro load contact terminal from manual ON condition by applying voltage to coil.  
OFF  
(1) Manual ON  
(3) Remote Reset  
Button is  
returned  
automatically.  
Button operating  
condition  
Power / Micro load  
contact terminal  
OFF  
ON  
OFF  
No voltage applied  
Coil terminal  
No voltage applied  
Voltage applied  
Switch circuit and operating condition  
OFF  
(1) Manual ON  
(2) Manual OFF  
(3) Remote Reset  
1
2
4
1
3
2
4
1
3
2
4
1
2
4
+
+
+
+
Load  
Load  
Load  
Load  
3
3
-
-
-
-
Power  
supply  
Power  
supply  
Power  
supply  
Power  
supply  
* 5VDC applied to coil terminal  
Note: 1. The above circuit is referring to the 'A8GS-Dxxxx' model.  
4
A8GS  
Dimensions (Unit: mm) /Operating Characteristics  
A8GS-S1@05  
A8GS-S1@03  
A8GS-P1@85  
A8GS-P1@15*  
A8GS-P1@83  
A8GS-P1@13*  
14.9  
12.2  
30  
30  
14.9  
12.2  
ON  
OFF  
ON  
OFF  
1.3  
4.75  
27  
14.3  
10  
0.8  
27  
14.3  
CT Connector  
CT Connector  
CT Connector  
Operating force (OF)  
1.0 ± ±0.6 N  
Operating force (OF)  
1.5 ± ±0.9 N  
A8GS-C1@85  
A8GS-C1@15*  
A8GS-C1@83  
A8GS-C1@13*  
A8GS-D1@85  
A8GS-D1@15*  
A8GS-D1@83  
A8GS-D1@13*  
30  
30  
14.9  
14.9  
12.2  
12.2  
ON  
OFF  
ON  
OFF  
1.3  
4.75  
1.3  
4.75  
0.8  
10  
0.8  
10  
11.5 0.8  
14.3  
27  
27  
14.3  
CT Connector  
CT Connector  
CT Connector  
Operating force (OF)  
2.0 ± ±1.2 N  
Operating force (OF)  
2.0 ± ±1.2 N  
A8GS-@@@@0  
(No reset function model)  
Accessories parts (Sold Separately)  
Protector can improve resistance against external force to  
the actuator from side (angled) direction.  
30  
14.9  
12.2  
Protector  
Model: A8GS-211(P)  
Color: Black  
Mounting image  
ON  
OFF  
8.8  
33.6  
22.5  
27  
14.3  
The above model is referring the 'A8GS-S1100'.  
No reset function models are without coil circuit.  
Specifications are same with reset function models.  
Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
Note: 2. When initial operation or operation after reset, operating force is increased, due to switch structure.  
Note: 3. TV-8 approved models are same outline and characteristics with standard models.  
* Solder terminals model has different hole shape, compare with Quick-connect terminals. Outline and characteristics are same.  
5
A8GS  
Panel Cutout  
Panel thickness: 0.8 to 2.3 mm  
27.7 0.1  
R by cutting  
ON  
Panel cutout design is for prevention of false insertion.  
Please be careful about the direction of the protrusion.  
OFF  
26.5 0.1  
The rollover of the panel shall be on the front face.  
And panel back side shall be Edge shape by processing.  
Edge  
(Operating surface direction)  
Note: 1. Recommendation panel material is "SPCC", however, in case of soft material or Panel back side shape is not edge,  
mounting strength may down. Please check and try by actual mounting panel and set the Panel thickness and hole dimension.  
Precautions  
Handling  
WARNING  
Do not apply excessive operating force to the switch.  
Do not drop or apply the excessive shock.  
Do not wire the switch or touch any terminal of the  
Switch while power is being supplied. Or it may result in  
electric shock.  
Otherwise the switch may be damaged or deformed.  
Do not impose force to operating part from an angle, Otherwise the  
switch may be damaged or deformed.  
Cautions  
Use the switch within the rated voltage and current ranges, otherwise  
the switch may have deteriorated durability. Radiate heat, or burn out.  
This particularly applies to the instantaneous voltages and currents  
when switching.  
Correct  
Incorrect  
Caution of usage  
Environment for storage and use  
Mounting  
To prevent the terminals color change and others while storage,  
Do not keep for a long term in the following conditions.  
(1) High temperature, high humid environment  
(2) Corrosive gas  
Easy to mount by snap fitting.  
Do not impose excessive force on switch at the time of panel mounting.  
Do not detach the switch after installed. Otherwise, the holding  
strength may be loose.  
(3) The place where the direct rays of the sun  
(4) The place where the sea breeze  
Apply the force to housing when installing to panel. Do not apply  
the force to the button (rocker) part when installing to the panel.  
(5) Environmental with a sudden temperature change  
This switch is not sealed to prevent from entering dust and liquid.  
Do not use under dust and liquid condition.  
Pushing position  
Switch shall not be icing or condensation.  
Strong magnetic field may cause malfunction.  
Check function is recommended under practical use conditions.  
Using Micro Loads  
In case of using the switch under the micro loads, please refer the  
Minimum applicable load and set the load more than minimum  
applicable load.  
Wiring  
Confirm the size of the receptacles and be sure to connect them firmly.  
Use an appropriate wire allowable to carry current.  
Be sure that there is no mechanical stress on terminals and coil terminals.  
Otherwise, the switch may malfunction and/or damaged.  
(Example: Too strong wiring)  
Even when using micro load within the operating range, if inrush  
current occurs, it may increase contact wear and so deteriorate  
durability. Therefore, insert a contact protection circuit where  
necessary.  
The minimum applicable load is the L-level reference value.  
This value indicates the malfunction reference level for the  
reliability level of 60 %. (λ±60)  
The equation, λ 60 = 0.5 x 10-6 /operations indicates that the  
estimated malfunction rate is less than 1/2,000,000 operations with  
a reliability level of 60 %.  
Take appropriate insulation distance between switch terminal and  
other metal parts after wiring.  
Coil has polarity, please confirm polarity when wiring.  
Do not apply continuous voltage more than 10 seconds at any  
time. Otherwise, insulation deterioration may occur by heat of coil.  
Please consider the circuit design.  
Reverse voltage may cause of accurate discrete semiconductor  
devices. In case of controlling by accurate discrete semiconductor  
devices, Please consider the circuit design. (Example : add the  
surge absorbing circuit)  
RoHS Compliant  
The "RoHS Compliant" designation indicates that the listed models  
do not contain the six hazardous substances covered by the RoHS  
Directive.  
Reference: The following standards are used to determine  
compliance for the six substances.  
Lead  
Mercury  
Cadmium  
: 1,000 ppm max.  
: 1,000 ppm max.  
: 100 ppm max.  
In case of manual soldering, soldering time is max 4 sec by soldering  
iron (Max 350 C at the iron tip) and do not add the stress to terminals.  
Hexavalent chromium : 1,000 ppm max.  
°
PBB  
PBDE  
: 1,000 ppm max.  
: 1,000 ppm max.  
In case of touching the soldering iron to the root of terminals, it may  
cause Housing parts melt.  
6
MEMO  
7
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
CSM_3_1_1216  
Cat. No. A222-E1-03  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
1014(0313)(O)  

相关型号:

A8GS-P1213

Minimum size class in the industry Rocker switch with reset function
OMRON

A8GS-P1215

Minimum size class in the industry Rocker switch with reset function
OMRON

A8GS-P1280

Rocker Switch,
OMRON

A8GS-P1283

Minimum size class in the industry Rocker switch with reset function
OMRON

A8GS-P1285

Minimum size class in the industry Rocker switch with reset function
OMRON

A8GS-P1310

Rocker Switch,
OMRON

A8GS-P1313

Minimum size class in the industry Rocker switch with reset function
OMRON

A8GS-P1315

Minimum size class in the industry Rocker switch with reset function
OMRON

A8GS-P1380

Rocker Switch,
OMRON

A8GS-P1383

Minimum size class in the industry Rocker switch with reset function
OMRON

A8GS-P1385

Minimum size class in the industry Rocker switch with reset function
OMRON

A8GS-S1103

Minimum size class in the industry Rocker switch with reset function
OMRON