Delay OFF Rocker Switch  
A8GS-T  
Minimum size class in the industry  
Remote Reset Rocker Switch with Delay OFF Function  
• Rocker switch with Delay OFF Function. Switch is kept to turn ON, even  
if button is operated to turn OFF, and Switch is turned OFF by external  
signal.  
• Zero standby power with Reset function, switching OFF by external signal.  
• Preventing from application trouble such as a data lost or circuit damage  
by forced power OFF.  
• Timing control of main power switch turn OFF for safety application  
design with Delay OFF function.  
• Contact gap of 3 mm minimum.  
• UL and cUL standard approved, Conforming to EN standards.  
(Please refer the Precautions)  
RoHS Compliant  
Usage example  
Saving energy by cutting standby power.  
Saving energy by preventing forgetting turn OFF main power.  
Turning OFF main power by remote.  
Turning OFF main power of many equipments at the same time.  
Timing control of main power switch turn OFF for safety design.  
Preventing from circuit and data damage by power flicker.  
*
There are 2 kinds of main models A8GS. (Delay OFF Function model and Remote Reset model) With regard to the models with Delay OFF Function, please refer to the other catalog.  
List of Models  
Signal Contact Terminal: SPST + Power Contact Terminal: DPST  
Contact Form  
Signal Contact Terminal × 1 + Power Contact Terminal × 2  
1 to 4: Power contact terminal  
a, b: Signal contact terminal  
+, -: Coil terminal  
+
1
a
3
2
b
4
Quantity  
per box  
-
Signal Contact Terminal: CT Connector  
Power Contact Terminal: Quick-connect  
terminals #187(t=0.8)  
Signal Contact Terminal: CT Connector  
Power Contact Terminal: Solder termi-  
nals  
Terminals  
No Marking  
A8GS-T1185K  
A8GS-T1115K  
A8GS-T1285K  
A8GS-T1215K  
50  
Marking on caps  
A8GS-T1385K  
A8GS-T1315K  
Note: 1. This is not general 3 pole switch.  
(1) Signal contact terminal is only for detecting button ON/OFF.  
(2) Power contact terminal is for turning ON/OFF of circuit. Switch is turned OFF by external signal only, after turning OFF of button.  
1
A8GS-T  
Ratings  
Contact Ratings  
Rated current  
(Resistive load)  
Rated voltage  
125 VAC  
250 VAC  
5 VDC  
16 A  
10 A  
0.2 A  
Power Contact Terminal  
Signal Contact Terminal  
Note: 1. The above ratings were tested under the following conditions:  
(1) Ambient temperature : 20 ± ±2 °C  
(2) Ambient humidity  
: 65 ± ±5 % RH  
(3) Switching frequency : 7 times/min  
Reset Coil Ratings  
Rated voltage, current  
Operating voltage  
range  
Coil resistance  
(Coil temperature: 20 2 °C)  
Rated usage cycle  
ON: 50 to 100 ms  
OFF: Min 5 sec  
5 VDC 455 mA  
4.5 to 5.5 VDC  
11 Ω±± ±20 %  
Note: 1. Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle.  
Otherwise the performance of the coil may be deteriorated.  
Note: 2. In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMRON sales representative.  
Contact specifications  
Signal contact  
Gold alloy  
3 mm  
Power contact  
Silver alloy  
3 mm  
Material  
Contact gap  
Minimum applicable  
load (Reference value) *  
3 VDC 1 mA  
5 VDC 200 mA  
* Please refer to '' Using Micro loads'' in ''Precautions'' for more information on the minimum applicable load.  
Characteristics  
Mechanical  
Switch operation: 20 times/min max, Coil operation: 7 times/min max  
7 times/min max  
Permissible operating  
frequency  
Electrical  
Insulation resistance  
100 MΩ min (at 500 VDC with insulation tester)  
100 mΩ max (6 VDC to 8 V, 1 A Voltage drop method)  
100 mΩ max (6 VDC to 8 V, 0.1 A Voltage drop method)  
Power contact terminal  
Signal contact terminal  
Contact resistance  
(initial value)  
Between terminals of the  
same polarity  
2,000 VAC 50/60 Hz 1 min  
2,000 VAC 50/60 Hz 1 min  
4,000 VAC 50/60 Hz 1 min  
4,000 VAC 50/60 Hz 1 min  
Between terminals of the  
different polarity  
Dielectric strength  
Between each terminals of the  
switch and terminals of coil  
Between each terminals of  
switch and ground  
Vibration resistance * Malfunction  
10 to 55 Hz 1.5 mm double amplitude (Malfunction 1 ms max)  
300 m/s2 min (Malfunction 1 ms max)  
1000 m/s2 max  
Malfunction  
Shock resistance *  
Destruction  
Ambient operating temperature  
Ambient operating humidity  
10 to +55 °C (with no icing or condensation, 60 % RH max)  
90 % RH max (+5 to 35 °C with no icing or condensation)  
Switch operation: 30,000 operations min, Coil operation: 10,000 operations min  
Switch operation: 10,000 operations min, Coil operation: 10,000 operations min  
IEC IP40  
Mechanical  
Durability  
Electrical  
Degree of protection  
Contact release time **  
100 ms max  
Weight  
A8GS-TxxxxK: Around 15 g  
Note: 1. Above specification values are initial values.  
* For the testing condition in individual specification, contact your OMRON sales representative.  
** Time from voltage applied to reset coil to actual contacts opening.  
2
A8GS-T  
Approved Safety Standards  
UL (UL61058-1)  
TÜV (EN61058-1)  
Approved safety  
standards ratings  
16 A 125 VAC  
Approved safety  
standards ratings  
10(4) A 250 VAC  
Power contact terminal  
Signal contact terminal  
Power contact terminal  
10 A 250 VAC  
0.2 A 5 VDC  
Signal contact terminal  
Note: 1. There are no approved models of TV-8 rating for Delay OFF Function models.  
Connector for Signal Switch Circuit and Coil Circuit  
CT connectors produced by Tyco Electronics Corporation or XR connectors produced by JST shall be used  
for connection of Signal and Coil circuit. Other connectors shall not be used.  
Tyco Electronics Corporation: CT connecter  
Pressure welding type  
JST: XR Connector  
Cramping type  
Connector  
Terminal no.  
Connection with  
Switch  
Contact  
Housing  
179228-3  
179228-2  
AWG #30-26  
AWG #26-22  
AWG #28-26  
AWG #24  
AWG #28-26  
1
2
3
1
2
a (Switch COM)  
---  
Signal  
contact terminal  
173977-3  
173977-2  
2-179694-3  
03XR-6@-P*  
b (Switch NO)  
+ (Coil)  
179609-1  
179227-1  
Coil terminal  
2-179694-2  
02XR-6@-P*  
- (Coil)  
*
@ indicates Housing color.  
3
A8GS-T  
Operation  
Delay OFF Function  
Power contacts are kept in ON status, even if button is operated to turn OFF by manual operation of button.  
And Switch is turned OFF by external signal to coil embedded in switch.  
(1) Signal contact terminal and Power contact terminal are turned ON by manual operation of button.  
(2) Power contact terminal is kept in ON status, even if button is operated to turn OFF by manual operation.  
Only Signal contact terminal is turned OFF.  
(3) Power contact terminal is turned OFF when external signal is applied to coil.  
Furthermore, it is able to turn OFF both signal and power contact terminals from manual ON condition at the same time by  
applying voltage to coil as Remote Reset Function.  
Delay OFF Function Operation  
OFF  
(1) Manual ON  
(2) Manual  
(3) Delay OFF  
Button operating  
condition  
Power switch terminal  
is returned automatically.  
Signal contact terminal  
Power contact terminal  
Coil terminal  
OFF  
OFF  
ON  
OFF  
ON  
OFF  
No voltage applied  
No voltage applied  
Voltage applied  
Remote Reset Function Operation  
OFF  
Button operating  
condition  
(1) Manual  
(3) Remote Reset  
Button is  
returned  
automatically.  
Signal contact terminal  
Power contact terminal  
Coil terminal  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
No voltage applied  
No voltage applied  
Voltage applied  
Note: 1. Once switch is turned ON, Power contact terminal is not able to be turned OFF by manual operation.  
Please apply the voltage to the coil in order to turn OFF Power switch circuit.  
Switch circuit and operating condition  
OFF  
(1) Manual ON  
(2) Manual OFF  
(3) Delay OFF / Remote Reset  
1
2
1
2
1
2
1
2
+
+
+
+
a
3
b
4
a
3
b
4
a
3
b
4
a
3
b
4
Load1  
Load1  
Load1  
Load1  
-
-
-
-
Power  
supply 1  
Power  
supply 1  
Power  
supply 1  
Power  
supply 1  
Load2  
Load2  
Load2  
Load2  
Power  
Power  
Power  
Power  
supply 2  
supply 2  
supply 2  
supply 2  
*5 VDC applied to coil terminal  
4
A8GS-T  
Dimensions (Unit: mm) /Operating Characteristics  
A8GS-T1@85K  
19.2  
16.5  
30  
ON  
OFF  
1.3  
4.75  
0.8  
10  
15.8 0.8  
18.6  
27  
CT Connector  
Operating force (OF)  
1.8 ± ±1.4 N  
CT Connector  
Note: 1. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions.  
Note: 2. At initial operation or operation after reset, operating force is increased, due to switch structure.  
Note: 3. Solder terminals model has different hole shape, comparing with Quick-connect terminals. Outline and characteristics are same.  
Note: 4. No models of switch without delay off function (without coil), due to product design.  
Panel Cutout  
27.7 0.1  
Panel thickness: 0.8 to 2.3 mm  
R by cutting  
Panel cutout design is for prevention of false insertion.  
Please be careful about the direction of the protrusion.  
26.5 0.1  
OFF  
ON  
The rollover of the panel shall be on the front face.  
And panel back side shall be Edge shape by processing.  
Edge  
(Operating surface direction)  
Note: 1. Recommendation panel material is "SPCC", however, in case of soft material or Panel back side shape is not edge, mounting  
strength may down. Please check and try by actual mounting panel and set the Panel thickness and hole dimension.  
5
A8GS-T  
Precautions  
Handling  
WARNING  
Do not apply excessive operating force to the switch.  
Do not drop or apply the excessive shock.  
Otherwise the switch may be damaged or deformed.  
Do not impose force to operating part from an angle, Otherwise the  
switch may be damaged or deformed.  
Do not wire the switch or touch any terminal of the  
Switch while power is being supplied. Or it may result in  
electric shock.  
Cautions  
Use the switch within the rated voltage and current ranges, otherwise  
the switch may have deteriorated durability radiate heat, or burn out.  
This particularly applies to the instantaneous voltages and currents  
when switching.  
Correct  
Incorrect  
Caution of usage  
Environment for storage and use  
Mounting  
To prevent the terminals color change and others while storage,  
Do not keep for a long term in the following conditions.  
(1) High temperature, high humid environment  
(2) Corrosive gas  
Easy to mount by snap fitting.  
Do not impose excessive force on switch at the time of panel  
mounting.  
Do not detach the switch after installed. Otherwise, the holding  
strength may be loose.  
Apply the force to housing when installing to panel. Do not apply  
the force to the button (rocker) part when installing to the panel.  
(3) The place where the direct rays of the sun  
(4) The place where the sea breeze  
(5) Environmental with a sudden temperature change  
This switch is not sealed to prevent from entering dust and  
liquid.Do not use under dust and liquid condition.  
Switch shall not be icing or condensation.  
Pushing position  
Strong magnetic field may cause malfunction.  
Check function is recommended under practical use conditions.  
Using Micro Loads  
In case of using the switch under the micro loads, please refer the  
Minimum applicable load and set the load more than minimum  
applicable load.  
Wiring  
Confirm the size of the receptacles and be sure to connect them  
firmly.  
Even when using micro load within the operating range, if inrush  
current occurs, it may increase contact wear and so deteriorate  
durability.Therefore, insert a contact protection circuit where  
necessary.  
Use an appropriate wire allowable to carry current.  
Be sure that there is no mechanical stress on terminals and coil  
terminals.Otherwise, the switch may malfunction and/or damaged.  
(Example: Too strong wiring)  
The minimum applicable load is the L-level reference value.  
This value indicates the malfunction reference level for the  
reliability level of 60 %. (λ±60)  
The equation, λ 60 = 0.5 x 10-6 /operations indicates that the  
estimated malfunction rate is less than 1/2,000,000 operations with  
a reliability level of 60 %.  
RoHS Compliant  
Take appropriate insulation distance between switch terminal and  
other metal parts after wiring.  
Coil has polarity, please confirm polarity when wiring.  
Do not apply continuous voltage more than 10 seconds at any  
time. Otherwise, insulation deterioration may occur by heat of coil.  
Please consider the circuit design.  
Reverse voltage may cause of accurate discrete semiconductor  
devices. In case of controlling by accurate discrete semiconductor  
devices, Please consider the circuit design. (Example : add the  
surge absorbing circuit)  
In case of manual soldering, soldering time is max 4 sec by  
soldering iron (Max 350 °C at the iron tip) and do not add the stress  
to terminals.  
The "RoHS Compliant" designation indicates that the listed models  
do not contain the six hazardous substances covered by the RoHS  
Directive.  
Reference: The following standards are used to determine  
compliance for the six substances.  
Lead  
Mercury  
Cadmium  
Hexavalent chromium : 1,000 ppm max.  
PBB  
PBDE  
: 1,000 ppm max.  
: 1,000 ppm max.  
: 100 ppm max.  
: 1,000 ppm max.  
: 1,000 ppm max.  
In case of touching the soldering iron to the root of terminals, it may  
cause Housing parts melt.  
6
MEMO  
7
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
CSM_2_1_1216  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. A223-E1-02  
1014(0313)(O)  

相关型号:

A8GS-T1285K

Minimum size class in the industry Remote Reset Rocker Switch with Delay OFF Function
OMRON

A8GS-T1315K

Minimum size class in the industry Remote Reset Rocker Switch with Delay OFF Function
OMRON

A8GS-T1385K

Minimum size class in the industry Remote Reset Rocker Switch with Delay OFF Function
OMRON

A8H

BIAS RESISTOR TRANSISTOR, NPN SILICON SURFACE MOUNT TRANSISTOR WITH MONOLITHIC BIAS RESISTOR NETWORK
LRC

A8J

BIAS RESISTOR TRANSISTOR, NPN SILICON SURFACE MOUNT TRANSISTOR WITH MONOLITHIC BIAS RESISTOR NETWORK
LRC

A8K

BIAS RESISTOR TRANSISTOR, NPN SILICON SURFACE MOUNT TRANSISTOR WITH MONOLITHIC BIAS RESISTOR NETWORK
LRC

A8L

Miniature Rocker Switch
OMRON

A8L

BIAS RESISTOR TRANSISTOR, NPN SILICON SURFACE MOUNT TRANSISTOR WITH MONOLITHIC BIAS RESISTOR NETWORK
LRC

A8L-11-11N1

Miniature Rocker Switch
OMRON

A8L-11-11N2

Miniature Rocker Switch
OMRON

A8L-11-11N3

Miniature Rocker Switch
OMRON

A8L-11-11N6

Miniature Rocker Switch
OMRON