CS1W-EIP21 [OMRON]

SYSMAC CS-series EtherNet/IP Unit; SYSMAC CS系列的EtherNet / IP单元
CS1W-EIP21
型号: CS1W-EIP21
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

SYSMAC CS-series EtherNet/IP Unit
SYSMAC CS系列的EtherNet / IP单元

文件: 总8页 (文件大小:536K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CSYSSMA1C CWS-se-rieEs EItPherN2et1/IP Unit  
CSM_CS1W-EIP21_DS_E_5_1  
Introducing the New EtherNet/IP Unit.  
More Than 180,000 Words of Tag  
Data Link Capacity!  
• EtherNet/IP is an industrial multivendor network that uses  
Ethernet. Managed by the ODVA (Open DeviceNet  
Vendors Association), it has open standards and is used  
with a wide range of industrial devices.  
• The EtherNet/IP Unit supports tag data links to enable  
sharing data between devices at Ethernet nodes and a  
message service for sending and receiving data when  
required.  
• The EtherNet/IP Unit supports the same FINS/UDP and  
FINS/TCP functionality as Ethernet Units.  
CS1W-EIP21  
Features  
Large-capacity tag data links are easily enabled by simply setting connections, with no programming required.  
Tag data links can be used to exchange data with up to 256 nodes over up to 256 connections.  
Up to 256 connections can be set per Unit with up to 722 words of data per connection, for a total of up to 184,832 words of link data.  
(There is no limit to the data link capacity for the overall network.)  
Data concurrency is maintained within each connection (for up to 722 words).  
Tag data link settings can be changed for individual Units even while tag data links are being used on a network.  
Errors can be diagnosed using the Network Configurator, and system errors can be monitored with a wide array of status flags.  
System Configuration  
Network  
Configurator  
Switching hub  
Twisted-pair cable  
Built-in EtherNet/IP port on  
CJ2 CPU Unit  
(CJ2H-CPU6@-EIP/  
CJ2M-CPU3@)  
100 m  
max.  
CS1W-EIP21 EtherNet/IP  
Unit for CS-series  
CJ1W-EIP21  
EtherNet/IP Unit  
Ethernet (LAN) port  
CS-series  
PLC  
CJ-series  
PLC  
CJ-series  
PLC  
1
CS1W-EIP21  
Ordering Information  
International Standards  
The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus  
(Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.  
Contact your OMRON representative for further details and applicable conditions for these standards.  
EtherNet/IP Unit  
Current  
consumption (A)  
No. of  
unit  
numbers  
allocated  
Specifications  
Product  
name  
Unit type  
Model  
Standards  
Communications  
cable  
Communications  
functions  
Units per CPU  
Unit  
5 V 26 V  
system system  
EtherNet/IP  
Unit  
Tag Data Link  
Functions,  
Message  
Communications  
Functions  
Shielded twisted-pair  
(STP) cable  
Categories: 100 Ω at 5,  
5e  
CS1 CPU  
Bus Unit  
UC1, N, L,  
CE  
8 max.  
1
0.41  
CS1W-EIP21  
Industrial Switching Hubs  
Specifications  
Current  
consumption  
(A)  
Product name  
Appearance  
Accessories  
Model  
Standards  
No. of  
pors  
Failure  
detection  
Functions  
3
No  
0.22  
W4S1-03B  
Power supply  
connector  
UC, CE  
Quality of Service (QoS):  
EtherNet/IP control data priority  
Failure detection:  
Broadcast storm and LSI error detection  
10/100BASE-TX, Auto-Negotiation  
Industrial  
Switching Hubs  
5
5
No  
0.22  
0.22  
W4S1-05B  
W4S1-05C  
Power supply  
connector  
Yes  
Connector  
for informing  
error  
CE  
Recommended Network Devices  
The following table shows the devices recommended for use with the EtherNet/IP.  
Part  
Manufacturer  
Phoenix Contact  
Model number  
FL SWITCH SFN 8TX (8 ports)  
Inquires  
Phoenix Contact USA Customer Service  
CONTEC USA Inc.  
Switching Hub  
Contec USA, Inc.  
Cisco Systems, Inc.  
100BASE-TX  
SH8008(FIT)H (8 ports)  
WS-C2955T-12 (12 ports)  
Cisco Systems, Inc. Main Corporate HQ  
Twisted-pair  
cable  
Fujikura  
F-LINK-E 0.5mm × 4P  
Fujikura America, Inc.  
EtherNet/IP compliant cable  
STP Plug  
Connectors  
(Modular plug)  
Panduit Corporation  
Tsuko Company  
MPS588  
Panduit Corporation US Headquarters  
Tsuko Company Japan Headquarters  
Boots  
MK boot (IV) LB  
Note: 1. Always use a switching hub when using tag data links in the network.  
2. If a repeater hub is used for EtherNet/IP tag data links (cyclic communications), the network's communications load will increase, data  
collisions will occur frequently, and stable communications will be impossible.  
Mountable Racks  
CS1 System  
CS1D System  
Expansion  
Backplane (including  
Long-distance  
SYSBUS  
Remote  
I/O  
Slave  
Rack  
Expansion  
Backplane  
CPU Rack  
CS1W-BC  
CPU Rack  
C200HX/HG/  
HE Expansion  
I/O Rack  
Model  
Expansion Rack)  
CS1W-BI  
CS1D-BC  
CS1D-BI  
@@3  
@@2  
@@3  
@@2  
052  
042D 082S  
092  
082D  
Not  
supported  
CS1W-EIP21  
Unit version 2.0  
8 Units (per CPU Unit)  
Not supported  
8 Units (per CPU Unit)  
2
CS1W-EIP21  
EtherNet/IP Unit Specifications  
Item  
Specifications  
Model number  
CS1W-EIP21  
Type  
100Base-TX (See note.)  
CS-series PLCs  
Applicable PLCs  
Unit classification  
Mounting location  
Number of Units that can be mounted  
CS-series CPU Bus Unit  
CPU Rack or Expansion Rack  
8 max. (including Expansion Racks)  
25 words/Unit (one unit number’s words)  
Allocated CIO Area words  
(CPU Bus Unit words)  
These words contain control bits and flags, the target node PLC’s operating and error information, Unit status,  
communications status, registered/normal target node information, and FINS/TCP connection status.  
100 words/Unit (one unit number’s words)  
Allocated DM Area words  
(CPU Bus Unit words)  
CPU Unit  
words used  
These words contain the IP address display/setting area  
Any usable data area words  
User-set area  
Target node PLC’s operating and error information, and registered/normal target node information  
CPU Bus Unit System  
Setup  
Not used.  
The following settings are stored in the EtherNet/IP Unit’s non-volatile memory.  
Note: Unlike the regular Ethernet Units, the CPU Bus Unit Setup Area in the CPU Unit is not used for these settings.  
1. Unit setup (communications settings for the EtherNet/IP Unit, such as the IP address, DNS server settings, host  
name, baud rate, FINS/UDP settings, and FINS/TCP settings)  
Non-volatile memory within EtherNet/IP Unit  
(See note.)  
2. Tag data link settings (device parameters)  
Media access method  
Modulation method  
Transmission paths  
CSMA/CD  
Baseband  
Star form  
Baud rate  
100 Mbit/s (100Base-TX)  
Transfer  
specifications  
Shielded twisted-pair (STP) cable  
Categories: 100 Ω at 5, 5e  
Transmission media  
Transmission distance  
100 m (distance between hub and node)  
Number of cascade  
connections  
There is no limitation when a switching hub is used.  
Current consumption (Unit)  
Weight  
410 mA max. at 5 V DC  
171 g max.  
Dimensions  
35 × 130 × 101 mm (W × H × D)  
Other general specifications  
Other specifications conform to the general specifications of the CS-series  
Note: If tag data links are being used, use 100Base-TX. Otherwise, 10Base-T can be used, but this is not recommended.  
3
CS1W-EIP21  
Communications Specifications  
Item  
Specifications  
Number of connections  
256  
0.5 to 10,000 ms (in 0.5-ms units)  
Can be set independently for each connection.  
(Data is refreshed over the network at the preset interval and does not depend on  
Packet interval (refresh cycle)  
the number of nodes.)  
Allowed communications bandwidth  
per Unit  
6000 pps (See note 1.)  
Number of tag sets  
Tag types  
256  
CIO Area, DM Area, EM Area, Holding Area, and Work Area  
Number of tags per connection  
(= 1 tag set)  
8 (7 tags when the tag set contains the PLC status)  
Maximum link data size per node  
Tag data links  
184,832 words  
252 words or 722 words (See note 2.)  
Note: Data synchronicity is maintained within each connection.  
Maximum data size per connection  
(Cyclic  
communications)  
256  
Number of registrable tag sets  
CIP service  
(1 connection = 1 tag set)  
722 words  
Maximum size of 1 tag set  
(The PLC status uses 1 word when the tag set contains the PLC status.)  
Maximum number of tags that can be  
refreshed per CPU Unit cycle  
(See note 3.)  
Output/Transmission (CPU to EtherNet/IP): 19  
Input/Reception (EtherNet/IP to CPU): 20 (See note 4.)  
Data that can be refreshed per CPU  
Unit cycle (See note 3.)  
Output/Transmission (CPU to EtherNet/IP): 7,405 words  
Input/Reception (EtherNet/IP to CPU): 7,405 words  
Changing tag data link parameters  
during operation  
Supported (See note 5.)  
Multicast packet filter function  
(See note 6.)  
Supported  
Class 3 (connected)  
Number of connections: 128  
Explicit  
Number of clients that can communicate at one time: 32 max.  
Number of servers that can communicate at one time: 32 max.  
UCMM (unconnected)  
messaging  
CIP routing  
CS1W-EIP21, CJ1W-EIP21, CJ2H-CPU6@-EIP, CJ2M-CPU3@  
FINS/UDP  
Supported  
FINS service  
FINS/TCP  
16 connections max.  
Conforms to A5  
EtherNet/IP conformance test  
10BASE-T or 100BASE-TX  
Auto Negotiation or fixed settings  
Ethernet interface  
Note: 1. In this case, pps means "packets per second" and indicates the number of packets that can be processed in one second.  
2. To use 505 to 1,444 bytes as the data size, the system must support the Large Forward Open standard (an optional CIP specification).  
The SYSMAC CS/CJ-series Units support this standard, but before connecting to nodes of other companies, confirm that those devices  
also support it.  
3. If the maximum data size is exceeded, the data refreshing with the CPU Unit will extend over two or more cycles.  
4. If status layout is selected in the user settings, the maximum number of tags that can be received is 19 tags.  
5. If parameters are changed in the EtherNet/IP Unit, however, the EtherNet/IP Unit will be restarted. When other nodes are communicating  
with the affected node, the communications will temporarily time out and automatically recover later.  
6. Because the EtherNet/IP Unit is equipped with an IGMP client, unnecessary multicast packets can be filtered by using a switching hub  
that supports IGMP snooping.  
7. The EtherNet/IP Unit uses the TCP/UDP port numbers shown in the following table.  
Service  
Tag data links  
Class 3, UCMM  
DNS  
Protocol  
UDP  
Port number  
2222  
Remarks  
TCP/UDP  
UDP  
44818  
53  
Fixed value  
FINS/UDP service  
FINS/TCP service  
FTP  
UDP  
9600  
9600  
20, 21  
123  
TCP  
TCP  
Port numbers in the Unit Setup can be  
changed with the CX-Programmer.  
SNTP  
UDP  
SNMP  
UDP  
161  
SNMP trap  
UDP  
162  
4
CS1W-EIP21  
Network Configurator Requirements  
The Network Configurator Ver. 3.0 or higher is a software package designed for building, setting, and controlling a multi-vendor EtherNet/IP  
Network using OMRON's EtherNet/IP. It is included in CX-One version 3.0. The Network Configurator provides the following functions for building,  
setting, and controlling EtherNet/IP.  
Item  
Specification  
Refer to the CX-One Setup Manual (Cat. No. W463).  
CXONE-AL@@C-V@/CXONE-AL@@D-V@  
Operating environment  
CS1/CJ1  
CJ2  
Network  
connection  
method  
Serial interface  
Ethernet interface  
CPU Unit’s Peripheral or RS-232C port  
CPU Unit’s USB or RS-232C port  
CPU Unit’s Ethernet port  
EtherNet/IP Unit’s Ethernet port  
EtherNet/IP Unit’s Ethernet port  
Location on Network  
A single node address is used (only when directly connected to EtherNet/IP).  
Number of Units that can be connected to  
Network  
A single Network Configurator per Network (More than one Configurator cannot be used in the same system.)  
The Network configuration can be created and edited regardless of whether the Network Configurator is online or  
Network control functions  
Main functions  
offline.  
The Network configuration can be read from a file or the network.  
Configuration functions  
The EDS files used by the Network Configurator can be installed and deleted.  
Configurator network configuration files (*.ncf)  
Supported file formats  
Configuration files (*.ncf) created using the Network Configurator for EtherNet/IP (version 2) can be imported by  
selecting External Data - Import from the File Menu.  
External Interface  
CS1W-EIP21  
LED Indicators  
These indicators display the Unit and network status.  
Unit number setting switch  
This rotary switch sets the unit number on the CPU Unit with one hexadecimal digit.  
Node address setting switches  
These two rotary switches set the node address for the EtherNet/IP Unit on the  
EtherNet/IP network with two hexadecimal digits.  
This setting is also used as the host ID in the default IP address (192.168.250.@).  
Label showing IP address  
A label that can be used to show the IP address and subnet mask is provided.  
Ethernet connector  
The network is connected with shielded twisted-pair cable.  
Ethernet Connectors  
The following standards and specifications apply to the connectors for the Ethernet twisted-pair cable.  
Electrical specifications: Conforming to IEEE802.3 standards.  
Connector structure:  
RJ45 8-pin Modular Connector  
(conforming to ISO 8877)  
Connector pin  
Signal name  
Transmission data +  
Abbr.  
TD+  
Signal direction  
Output  
1
2
Transmission data −  
Reception data +  
Not used.  
TD−  
RD+  
Output  
3
Input  
4
5
Not used.  
6
Reception data −  
Not used.  
RD−  
Input  
7
8
Not used.  
Hood  
Frame ground  
FG  
5
CS1W-EIP21  
Ethernet Unit Function Comparison  
Support for function  
EtherNet/IP Unit or built-in EtherNet/IP port  
Unit version 1.0 Unit version 2.0  
Item  
Ethernet Unit  
Tag data link communications service  
CIP message communications service  
FINS/UDP service  
No  
Yes  
Yes  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
FINS/TCP service  
Socket service  
File transfer (FTP)  
No  
Yes  
No  
Mail send/receive  
No  
Web functions  
No  
No  
Automatic adjustment of PLC’s internal clock  
Simple backup function  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
Error log  
Response to PING command  
SNMP/SNMP trap  
CIDR function for IP addresses  
Online connection by EtherNet/IP using CX-One  
Online connection by Ethernet (FINS) using CX-One  
Online connection by EtherNet/IP using Network Configurator  
No  
No  
No  
No  
Yes  
No  
Yes  
Yes  
Dimensions  
(Unit: mm)  
CS1W-EIP21  
130mm  
35mm  
101mm  
6
CS1W-EIP21  
Related Manuals  
Manual  
Model  
Name  
Contents  
number  
Provides information on operating and installing EtherNet/IP Units, including  
details on basic settings, tag data links, and FINS communications.  
Refer to the Communications Commands Reference Manual (W342) for details  
on FINS commands that can be sent to CS-series and CJ-series CPU Units  
when using the FINS communications service.  
Refer to the Ethernet Units Operation Manual Construction of Applications  
(W421) for details on constructing host applications that use FINS  
communications.  
CS1W-EIP21  
CJ1W-EIP21  
CJ2H-CPU@@-EIP  
CJ2M-CPU3@  
W465  
EtherNet/IP Units Operation Manual  
Provides information on constructing host applications for 100Base-TX Ethernet  
Units, including functions for sending/receiving mail, socket service, automatic  
clock adjustment, FTP server functions, and FINS communications.  
CS1W-ETN21  
W421  
Ethernet Units Operation Manual  
Construction of Applications  
CJ1W-ETN21  
CS1G/H-CPU@@H  
CS1G/H-CPU-@@V1  
CS1W-SCU21  
CS1W-SCB21/41  
CJ1G/H-CPU@@H  
CJ1G-CPU@@  
CJ1W-SCU41  
Describes the C-series (Host Link) and FINS communications commands used  
when sending communications commands to CS-series and CJ-series CPU  
Units.  
Communications Commands  
Reference Manual  
W342  
W463  
Describes the setup procedures for the CX-One. Information is also provided on  
the operating environment for the CX-One.  
CXONE-AL@@C/D-V@  
CX-One Setup Manual  
7
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2010.3  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2010 All Right Reserved.  

相关型号:

CS1W-ETN21

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON

CS1W-HCA12-V1

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON

CS1W-HCA22-V1

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON

CS1W-HCP22-V1

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON

CS1W-HIO01-V1

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON

CS1W-KS001-E

CJ1 Ordering Guide
OMRON

CS1W-MC221-V1

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON

CS1W-MC421-V1

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON

CS1W-MCH71

Improve Equipment Design Efficiency and Shorten Tact Time
OMRON

CS1W-NC113

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON

CS1W-NC133

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON

CS1W-NC213

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
OMRON