D2AW
Sealed Ultra Subminiature Basic Switch
Long stroke seal switch with
high reliability and high
insulation performance
● <Clipping contact> Double reliability by twin
contacts (=Clipping contact). Foreign materials
are cleaned out by the sliding contacts.
● <Quiet operation> Quiet operating sound by
sliding contact construction is needed for high
grade car.
● <High insulation performance> High performance
of Insulation resistance by unique contact structure.
RoHS Compliant
Model Number Legend
D2AW-
-
@@@@@ @
1
2
3
4
5
6
1. Mounting Structure
A: Without posts
4. Contact Form
2: SPST-NC
BR: Long post on right
BL: Long post on left
C: M3-screw mounting model
ER: Short post on right
EL: Short post on left
3: SPST-NO
5. Terminals
D: Straight PCB terminals
H: Solder terminals
6. Option Code
2. Ratings
Customized Code
0: 0.1 A at 12 VDC
3. Actuator
0: Pin plunger
5: Long straight leaf lever
6: Leaf lever
7: Simulated roller leaf lever
8: Long leaf lever
1
D2AW
Sealed Ultra Subminiature Basic Switch
Due to the idiosyncrasies of the automotive parts industry, a business decision is required on individual items
to determine when to start supply. Contact your OMRON representative for information on individual models.
List of Models
Model Without posts
Long post on
right
Long post on
left
M3-screw
mounting model
Short post on
right
Short post on
left
Terminals
Contact Form
Actuator
Pin plunger
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
D2AW-A002H
D2AW-A003H
D2AW-A002D
D2AW-A003D
D2AW-A052H
D2AW-A053H
D2AW-A052D
D2AW-BR002H
D2AW-BR003H
D2AW-BR002D
D2AW-BR003D
D2AW-BR052H
D2AW-BR053H
D2AW-BR052D
D2AW-BL002H
D2AW-BL003H
D2AW-BL002D
D2AW-BL003D
D2AW-BL052H
D2AW-BL053H
D2AW-BL052D
D2AW-C002H
D2AW-C003H
D2AW-C002D
D2AW-C003D
D2AW-C052H
D2AW-C053H
D2AW-C052D
D2AW-ER002H D2AW-EL002H
D2AW-ER003H D2AW-EL003H
D2AW-ER002D D2AW-EL002D
D2AW-ER003D D2AW-EL003D
D2AW-ER052H D2AW-EL052H
D2AW-ER053H D2AW-EL053H
D2AW-ER052D D2AW-EL052D
Solder
terminals
PCB terminals
Long straight leaf
lever
Solder
terminals
PCB terminals
SPST-NO
D2AW-A053D
D2AW-BR053D
D2AW-BL053D
D2AW-C053D
D2AW-ER053D D2AW-EL053D
Leaf lever
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
D2AW-A062H
D2AW-A063H
D2AW-A062D
D2AW-A063D
D2AW-A072H
D2AW-A073H
D2AW-A072D
D2AW-BR062H
D2AW-BR063H
D2AW-BR062D
D2AW-BR063D
D2AW-BR072H
D2AW-BR073H
D2AW-BR072D
D2AW-BL062H
D2AW-BL063H
D2AW-BL062D
D2AW-BL063D
D2AW-BL072H
D2AW-BL073H
D2AW-BL072D
D2AW-C062H
D2AW-C063H
D2AW-C062D
D2AW-C063D
D2AW-C072H
D2AW-C073H
D2AW-C072D
D2AW-ER062H D2AW-EL062H
D2AW-ER063H D2AW-EL063H
D2AW-ER062D D2AW-EL062D
D2AW-ER063D D2AW-EL063D
D2AW-ER072H D2AW-EL072H
D2AW-ER073H D2AW-EL073H
D2AW-ER072D D2AW-EL072D
Solder
terminals
PCB terminals
Simulated roller
leaf lever
Solder
terminals
PCB terminals
SPST-NO
D2AW-A073D
D2AW-BR073D
D2AW-BL073D
D2AW-C073D
D2AW-ER073D D2AW-EL073D
Long leaf lever
SPST-NC
SPST-NO
SPST-NC
SPST-NO
D2AW-A082H
D2AW-A083H
D2AW-A082D
D2AW-A083D
D2AW-BR082H
D2AW-BR083H
D2AW-BR082D
D2AW-BR083D
D2AW-BL082H
D2AW-BL083H
D2AW-BL082D
D2AW-BL083D
D2AW-C082H
D2AW-C083H
D2AW-C082D
D2AW-C083D
D2AW-ER082H D2AW-EL082H
D2AW-ER083H D2AW-EL083H
D2AW-ER082D D2AW-EL082D
D2AW-ER083D D2AW-EL083D
Solder
terminals
PCB terminals
Contact Specifications
Specification
Material
Minimum applicable load ( see note )
Slide
Contact
Sliver Plated
5 VDC 1 mA
Note: For more information on the minimum applicable load, refer to Using Micro Loads.
Ratings
Rating voltage
Resistive load
12 VDC
0.1 A
Note: The rating values apply under the following test conditions.
1. Ambient temperature: 20 ± ±2°C
2. Ambient humidity: 65 ± ±5%
3. Operating frequency: 20 operations/min
2
D2AW
Sealed Ultra Subminiature Basic Switch
Characteristics
Permissible operating speed
30 mm to 500 mm/s (pin plunger models)
30 operations/min max.
20 operations/min max
Mechanical
Electrical
Permissible operating
frequency
Insulation resistance
100 MΩ min. (at 500 VDC)
100 mΩ max.
Contact resistance (initial value)
Between terminals of the same polarity
600 VAC 50/60 Hz 1min
1,500 VAC 50/60 Hz 1min
Between current-carrying metal parts and ground
Dielectric strength *1
Between terminals and non-current-carrying
metal parts
1,500 VAC 50/60 Hz 1min
Vibration resistance
Shock resistance
Malfunction
Destruction
Malfunction
Mechanical
Electrical
10 to 55 Hz, 1.5 mm double amplitude
1,000 m/s2 max.
300 m/s2 max.
200,000 operations min. (30 operations/min)
200,000 operations min. (20 operations/min)
IEC IP67
Durability *2
Degree of protection
Ambient operating temperature
Ambient operation humidity
Weight
-40 to 85°C (at 60%RH max.) (with no icing or condesenation)
95%RH max. (for +5 to +35°C)
Approx. 0.7 g (for pin plunger models with terminals)
Note: The data given above are initial values.
*1. The values for dielectric strength shown are for models with a Separator.
Refer to your OMRON website.
*2. For testing conditions, consult your OMRON sales representative.
Mounting Structure and Reference Positions for Operating Characteristics (Unit: mm)
● Without posts
D2AW-A@
● Short post
D2AW-E@
Mounting Hole Dimensions (Reference)
2.4+0.1 dia. holes
(dep0th:
D2AW-E@: 1.5 mm min.
D2AW-B@: 5 mm min.)
4
0.1
8
1.7 dia.
1.7 dia.
2.6
FP
OP
FP
TTP
3
OP
TTP
7
2.4+0.1
±±.±5
2.6
0
6.5
0.1
8
±
13.3
5.3
1.5–±.2
5.3
13.3
● Long post
D2AW-B@
● M3-screw Mounting Models
D2AW-C@
2.65
8±±.1
13±±.1
1.7 dia.
3 dia.-±±.1
FP
3.3 dia. ±±.15
3
OP
FP
OP
TTP
2.6±±.±5
TTP
6
6.5
6.5
+±.13
3.1
-±.±3
1.5-±±.1
1.5-±±.1
5.3
18.5
5-±±.2
13.3
5.3
3
D2AW
Sealed Ultra Subminiature Basic Switch
Terminals (Unit: mm)
<PCB Mounting Dimensions
(Reference)>
● PCB terminals
SPST-NO
SPST-NC
SPST-NO
SPST-NC
2-1+0.1 dia. holes
2-1+0.1 dia. holes
0
0
± 0.1
10.16
± 0.1
5.08
2.5
2.5
2-0.6
5.08
2-0.6
0.4
10.16
0.4
● Solder terminals
SPST-NO
SPST-NC
3.5
1.8
1.8
2-2
0.4
0.4
2-2
2-1.2
2-1.2
8.76
4.38
4
D2AW
Sealed Ultra Subminiature Basic Switch
Dimensions (Unit: mm) / Operating Characteristics
The following illustrations and drawings are for solder terminal models. PCB terminal models are omitted from the drawings. Refer to Terminals for these terminals.
When ordering, replace @ with the code for the rating that you need. For the combination of models, refer to List of Models.
● Pin plunger
D2AW-@00@@
4
1.7 dia.
Operating
characteristics
Without
posts
Models with
Posts
Type
A
Operating Force
Releasing Force
OF Max.
RF Min.
1.00N {101 gf}
0.10N {10 gf}
FP
OP
TTP
Overtravel
Movement Differential MD Max.
OT
1.4 mm (reference value)
0.25 mm
7
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP
11.2 mm
10.4 ± 0.3 mm 6.4 ± 0.3 mm
9.1 mm
7.2 mm
5.1 mm
●Long straight leaf lever
D2AW-@05@@
Without
posts
Models with
Posts
Operating characteristics
Type
A
3.4
Operating Force
Releasing Force
OF Max.
RF Min.
1.50N {152 gf}
0.10N {10 gf}
2.65
0.1
8
Overtravel
Movement Differential MD Max.
OT
2.5 mm (reference value)
0.7 mm
(0.35)
(1.7)
FP
OP
TTP
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP
15.9 mm
12.1 ± ±0.8 mm
10.0 mm
11.9 mm
8.1 ± ±0.8 mm
6.0 mm
3
6.5
●Leaf lever
D2AW-@06@@
A
2.65
0.1
8
3.4
Operating
characteristics
Without
posts
Models with
Posts
Type
(0.35)
(1.7)
Operating Force
Releasing Force
OF Max.
RF Min.
2.00N {203 gf}
0.20N {20 gf}
FP
OP
TTP
Overtravel
Movement Differential MD Max.
OT
1.8 mm (reference value)
0.5 mm
3
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP
13.3 mm
11.4 ± ±0.5 mm
9.8 mm
9.3 mm
7.4 ± ±0.5 mm
5.8 mm
6.5
A
●Simulated roller leaf lever
D2AW-@07@@
Operating
characteristics
Without
posts
Models with
Posts
Type
3.4
2.65
0.1
8
Operating Force
Releasing Force
OF Max.
RF Min.
1.80N {183gf}
0.20N {20 gf}
(0.35)
(1.7)
FP
OP
TTP
Overtravel
Movement Differential MD Max.
OT
2.0 mm (reference value)
0.5 mm
3
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP
17.0 mm
14.8 ± ±0.5 mm 10.8 ± ±0.5 mm
12.9 mm
13.0 mm
6.5
8.9 mm
A
●Long leaf lever
D2AW-@08@@
(18)
3.4
Operating
characteristics
Without
posts
Models with
Posts
Type
Operating Force
Releasing Force
OF Max.
RF Min.
0.90N {91 gf}
0.05N {5 gf}
2.65
1
8
FP
Overtravel
Movement Differential MD Max.
OT
2.8 mm (reference value)
0.7 mm
OP
TTP
(0.45)
(1.7)
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP
23.0 mm
19.0 mm
19.4 ± ±1.5 mm 15.4 ± ±1.5 mm
16.8 mm
12.8 mm
3
6.5
Note1. Unless otherwise specified, a tolerance of ± 0.2 mm applies to all dimensions.
Note2. The operating characteristics are for operation in the A direction ( ).
5
D2AW
Sealed Ultra Subminiature Basic Switch
Precautions
Please refer to "Safety Precautions for All Detection Switches" for correct use.
Cautions
Correct Use
●Degree of Protection
●Mounting
• Do not use this product underwater.
• Turn OFF the power supply before mounting or removing the
Switch, wiring, or performing maintenance or inspection.
Failure to do so may result in electric shock or burning.
• For models with posts, secure the posts by thermal caulking or
by pressing into an attached device. When pressed into an
attached device, provide guides on the opposite ends of the
posts to ensure that they do not fall out or rattle.
Although molded lead wire models satisfy the test conditions
for the standard given below, this test is to check the ingress of
water into the switch enclosure after submerging the Switch in
water for a given time. Satisfying this test condition does not
mean that the Switch can be used underwater.
JIS C0920:
Degrees of protection provided by enclosures of electrical
apparatus (IP Code)
Thermal caulking conditions varies according to the equipment,
jig and base used for switch mounting. Consult your OMRON
sales representative for details.
IEC 60529:
Degrees of protection provided by enclosures (IP Code)
Degree of protection: IP67
●Operating Body
• Use an operating body with low frictional resistance and of a
shape that will not interfere with the sealing rubber, otherwise
the plunger may be damaged or the sealing may deteriorate.
(check water intrusion after immersion
for 30 min. submerged 1m underwater)
• Do not operate the Switch when it is exposed to water spray,
or when water drops adhere to the Switch surface, or during
sudden temperature changes, otherwise water may intrude
into the interior of the Switch due to a suction effect.
• Prevent the Switch from coming into contact with oil and
chemicals.
●Handling
• Do not handle the Switch in a way that may cause damage to
the sealing rubber.
• When handling the Switch, ensure that pressure is not applied
to the posts in the directions shown in the following diagram.
Also, ensure that uneven pressure or pressure in a direction
other than the operating direction is not applied to the Actuator
as shown in the following diagram. Otherwise, the post,
Actuator, or Switch may be damaged, or the service life may
be reduced.
Otherwise, damage to or deterioration of Switch materials may
result.
• Do not use the Switch in areas where it is exposed to silicon
adhesives, oil, or grease. Otherwise faulty contact may result
due to the generation of silicon oxide.
●Soldering
When soldering the lead wire to the terminal, first insert the
lead wire conductor through the terminal hole and then
conduct soldering.
Make sure that the temperature of the soldering iron tip does
not exceed 300°C, and complete the soldering within 3
seconds. Do not apply any external force for 1 minute after
soldering.
Soldering at an excessively high temperature or soldering for
more than 3 seconds may deteriorate the characteristics of the
Switch.
●Using Micro Loads
In case of automatic soldering, please do not apply the heat
beyond 260°C within 5 seconds. Pay careful attention so that
flux or solder liquid does not flow over the edge of the PCB
panel.
• Even when using micro load models within the operating
range shown below, if inrush/surge current occurs, it may
increase the contact wear and so decrease durability.
Therefore, insert a contact protection circuit where necessary.
●Side-actuated (Cam/Dog) Operation
• When using a cam or dog to operate the Switch, factors such
as the operating speed, operating frequency, push-button
indentation, and material and shape of the cam or dog will
affect the durability of the Switch. Confirm performance
specifications under actual operating conditions before using
the Switch in applications.
6
MEMO
7
•±Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•±Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. B130-E1-02
0517(1115)