D3V
Reliable Basic Switch with
External Lever
Miniature Basic Switch
● Available by 21 A, 16 A, 11 A, 6 A and 0.1 A
models, all with self-cleaning contacts.
● Available with internally or externally fitted
levers.
D
3
V
RoHS Compliant
Model Number Legend
1
2
3
4
5
6
7
8
9
D3V-
-
-
-
@ @ @ @ @ @ @ @ @
1. Ratings
21 : 20 (4) A at 250 VAC
5. Contact Form
1
2
3
: SPDT
16 : 16 (3) A at 250 VAC
11 : 11 (3) A at 250 VAC
: SPST-NC
: SPST-NO
6
: 16 (2) A at 250 VAC
6. Terminals
01 : 0.1 A at 125 VAC
A
: Solder terminals
C2 : Quick-connect terminals (#187)
2. Contact Gap
None : 1 mm (F gap)
: 0.5 mm (G gap)
C
: Quick-connect terminals (#250)
7. Maximum Operating Force
: 1.96 N {200 gf}
4A : 1.23 N {125 gf}
G
5
3. Actuator
None : Pin plunger
4
3
2
: 0.98 N {100 gf}
: 0.49 N {50 gf}
: 0.25 N {25 gf}
1
2
3
4
5
6
: Short hinge lever
: Hinge lever
: Long hinge lever
Note. These values are for the pin plunger models.
8. Mounting Hole Size
None : 3.1 mm
: Simulated roller lever
: Short hinge roller lever
: Hinge roller lever
K : 2.9 mm
9. Special Code
None : Standard
4. Hinge Position
None : Internal/Far from plunger
H
E
: High temperature (125°C) (See note)
: Special rating: 21 (8) A
8.1
Note. Consult your OMRON sales representative for high
temperature models.
K
: External/Near plunger
14.3
1
D3V
Miniature Basic Switch
List of Models
●21 A (OF: 1.23 N {125 gf})
Terminals
Maximum operating
Quick-connect
terminals (#250)
(C)
Ratings
Contact gap
Actuators
Pin plunger
Contact form
SPDT
force (OF)
D3V-21G-1C4A
SPDT-NC
SPDT-NO
SPDT
1.23 N {125 gf}
1.23 N {125 gf}
0.78 N {80 gf}
0.44 N {45 gf}
0.83 N {85 gf}
1.42 N {145 gf}
0.79 N {80 gf}
-
-
Short hinge lever
Hinge lever
D3V-21G1-1C4A
SPDT-NC
SPDT-NO
SPDT
-
D
3
V
-
D3V-21G2-1C4A
SPDT-NC
SPDT-NO
SPDT
-
-
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
D3V-21G3-1C4A
0.5 mm
(G gap)
21 A
SPDT-NC
SPDT-NO
SPDT
-
-
D3V-21G4-1C4A
SPDT-NC
SPDT-NO
SPDT
-
-
D3V-21G5-1C4A
SPDT-NC
SPDT-NO
SPDT
-
-
D3V-21G6-1C4A
SPDT-NC
SPDT-NO
-
-
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
●16 A (OF: 1.96 N {200 gf})
Terminals
Maximum operating
Quick-connect
terminals (#187)
(C2)
Quick-connect
terminals (#250)
(C)
Solder terminals
(A)
Ratings
Contact gap
Actuators
Pin plunger
Contact form
SPDT
force (OF)
D3V-16-1A5
D3V-16-2A5
D3V-16-3A5
D3V-161-1A5
D3V-161-2A5
D3V-161-3A5
D3V-162-1A5
D3V-162-2A5
D3V-162-3A5
D3V-163-1A5
D3V-163-2A5
D3V-163-3A5
D3V-164-1A5
D3V-164-2A5
D3V-164-3A5
D3V-165-1A5
D3V-165-2A5
D3V-165-3A5
D3V-166-1A5
D3V-166-2A5
D3V-166-3A5
D3V-16-1C25
D3V-16-2C25
D3V-16-3C25
D3V-161-1C25
D3V-161-2C25
D3V-161-3C25
D3V-162-1C25
D3V-162-2C25
D3V-162-3C25
D3V-163-1C25
D3V-163-2C25
D3V-163-3C25
D3V-164-1C25
D3V-164-2C25
D3V-164-3C25
D3V-165-1C25
D3V-165-2C25
D3V-165-3C25
D3V-166-1C25
D3V-166-2C25
D3V-166-3C25
D3V-16-1C5
D3V-16-2C5
D3V-16-3C5
D3V-161-1C5
D3V-161-2C5
D3V-161-3C5
D3V-162-1C5
D3V-162-2C5
D3V-162-3C5
D3V-163-1C5
D3V-163-2C5
D3V-163-3C5
D3V-164-1C5
D3V-164-2C5
D3V-164-3C5
D3V-165-1C5
D3V-165-2C5
D3V-165-3C5
D3V-166-1C5
D3V-166-2C5
D3V-166-3C5
SPDT-NC
SPDT-NO
SPDT
1.96 N {200 gf}
1.96 N {200 gf}
1.23 N {125 gf}
0.69 N {70 gf}
1.23 N {125 gf}
2.35 N {240 gf}
1.23 N {125 gf}
Short hinge lever
Hinge lever
SPDT-NC
SPDT-NO
SPDT
SPDT-NC
SPDT-NO
SPDT
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
1 mm
(F gap)
16 A
SPDT-NC
SPDT-NO
SPDT
SPDT-NC
SPDT-NO
SPDT
SPDT-NC
SPDT-NO
SPDT
SPDT-NC
SPDT-NO
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
2
D3V
Miniature Basic Switch
●11 A (OF: 1.96 N {200 gf})
Terminals
Maximum operating
Quick-connect
terminals (#187)
(C2)
Quick-connect
terminals (#250)
(C)
Solder terminals
(A)
Ratings
Contact gap
Actuators
Pin plunger
Contact form
SPDT
force (OF)
D3V-11-1A5
D3V-11-1C25
D3V-11-1C5
SPDT-NC
SPDT-NO
SPDT
1.96N {200 gf}
1.96N {200 gf}
1.23N {125 gf}
0.69N {70 gf}
1.23N {125 gf}
2.35N {240 gf}
1.23N {125 gf}
-
-
-
-
-
-
Short hinge lever
Hinge lever
D3V-111-1A5
D3V-111-1C25
D3V-111-1C5
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D
3
V
D3V-112-1A5
D3V-112-1C25
D3V-112-1C5
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
D3V-113-1A5
D3V-113-1C25
D3V-113-1C5
1 mm
(F gap)
11 A
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-114-1A5
D3V-114-1C25
D3V-114-1C5
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-115-1A5
D3V-115-1C25
D3V-115-1C5
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-116-1A5
D3V-116-1C25
D3V-116-1C5
SPDT-NC
SPDT-NO
-
-
-
-
-
-
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
●11 A (OF: 0.98 N {100 gf})
Terminals
Maximum operating
Quick-connect
terminals (#187)
(C2)
Quick-connect
terminals (#250)
(C)
Solder terminals
(A)
Ratings
Contact gap
Actuators
Pin plunger
Contact form
SPDT
force (OF)
D3V-11-1A4
D3V-11-1C24
D3V-11-1C4
SPDT-NC
SPDT-NO
SPDT
0.98N {100 gf}
0.98N {100 gf}
0.59N {60 gf}
0.34N {35 gf}
0.59N {60 gf}
1.18N {120 gf}
0.59N {60 gf}
-
-
-
-
-
-
Short hinge lever
Hinge lever
D3V-111-1A4
D3V-111-1C24
D3V-111-1C4
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-112-1A4
D3V-112-1C24
D3V-112-1C4
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
D3V-113-1A4
D3V-113-1C24
D3V-113-1C4
1 mm
(F gap)
11 A
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-114-1A4
D3V-114-1C24
D3V-114-1C4
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-115-1A4
D3V-115-1C24
D3V-115-1C4
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-116-1A4
D3V-116-1C24
D3V-116-1C4
SPDT-NC
SPDT-NO
-
-
-
-
-
-
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
3
D3V
Miniature Basic Switch
●6 A (OF: 0.98 N {100 gf})
Terminals
Maximum operating
Quick-connect
terminals (#187)
(C2)
Quick-connect
terminals (#250)
(C)
Solder terminals
(A)
Ratings
Contact gap
Actuators
Pin plunger
Contact form
SPDT
force (OF)
D3V-6-1A4
D3V-6-1C24
D3V-6-1C4
SPDT-NC
SPDT-NO
SPDT
0.98 N {100 gf}
0.98 N {100 gf}
0.59 N {60 gf}
0.34 N {35 gf}
0.59 N {60 gf}
1.18 N {120 gf}
0.59 N {60 gf}
-
-
-
-
-
-
Short hinge lever
Hinge lever
D3V-61-1A4
D3V-61-1C24
D3V-61-1C4
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D
3
V
D3V-62-1A4
D3V-62-1C24
D3V-62-1C4
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
D3V-63-1A4
D3V-63-1C24
D3V-63-1C4
1 mm
(F gap)
6 A
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-64-1A4
D3V-64-1C24
D3V-64-1C4
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-65-1A4
D3V-65-1C24
D3V-65-1C4
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-66-1A4
D3V-66-1C24
D3V-66-1C4
SPDT-NC
SPDT-NO
-
-
-
-
-
-
●6 A (OF: 0.49 N {50 gf})
Terminals
Maximum operating
Quick-connect
terminals (#187)
(C2)
Quick-connect
terminals (#250)
(C)
Solder terminals
(A)
Ratings
Contact gap
Actuators
Pin plunger
Contact form
SPDT
force (OF)
D3V-6G-1A3
D3V-6G-1C23
D3V-6G-1C3
SPDT-NC
SPDT-NO
SPDT
0.49 N {50 gf}
0.49 N {50 gf}
0.59 N {60 gf}
0.20 N {20 gf}
0.29 N {30 gf}
0.59 N {60 gf}
0.29 N {30 gf}
-
-
-
-
-
-
Short hinge lever
Hinge lever
D3V-6G1-1A3
D3V-6G1-1C23
D3V-6G1-1C3
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-6G2-1A3
D3V-6G2-1C23
D3V-6G2-1C3
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
D3V-6G3-1A3
D3V-6G3-1C23
D3V-6G3-1C3
0.5 mm
Ggap)
6 A
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-6G4-1A3
D3V-6G4-1C23
D3V-6G4-1C3
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-6G5-1A3
D3V-6G5-1C23
D3V-6G5-1C3
SPDT-NC
SPDT-NO
SPDT
-
-
-
-
-
-
D3V-6G6-1A3
D3V-6G6-1C23
D3V-6G6-1C3
SPDT-NC
SPDT-NO
-
-
-
-
-
-
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
4
D3V
Miniature Basic Switch
●0.1 A (OF: 0.49 N {50 gf})
Terminals
Maximum operating
Quick-connect
terminals (#187)
(C2)
Quick-connect
terminals (#250)
(C)
Solder terminals
(A)
Ratings
Contact gap
Actuators
Pin plunger
Contact form
SPDT
force (OF)
D3V-01-1A3
D3V-01-2A3
D3V-01-3A3
D3V-011-1A3
D3V-011-2A3
D3V-011-3A3
D3V-012-1A3
D3V-012-2A3
D3V-012-3A3
D3V-013-1A3
D3V-013-2A3
D3V-013-3A3
D3V-014-1A3
D3V-014-2A3
D3V-014-3A3
D3V-015-1A3
D3V-015-2A3
D3V-015-3A3
D3V-016-1A3
D3V-016-2A3
D3V-016-3A3
D3V-01-1C23
D3V-01-2C23
D3V-01-3C23
D3V-011-1C23
D3V-011-2C23
D3V-011-3C23
D3V-012-1C23
D3V-012-2C23
D3V-012-3C23
D3V-013-1C23
D3V-013-2C23
D3V-013-3C23
D3V-014-1C23
D3V-014-2C23
D3V-014-3C23
D3V-015-1C23
D3V-015-2C23
D3V-015-3C23
D3V-016-1C23
D3V-016-2C23
D3V-016-3C23
D3V-01-1C3
D3V-01-2C3
D3V-01-3C3
D3V-011-1C3
D3V-011-2C3
D3V-011-3C3
D3V-012-1C3
D3V-012-2C3
D3V-012-3C3
D3V-013-1C3
D3V-013-2C3
D3V-013-3C3
D3V-014-1C3
D3V-014-2C3
D3V-014-3C3
D3V-015-1C3
D3V-015-2C3
D3V-015-3C3
D3V-016-1C3
D3V-016-2C3
D3V-016-3C3
SPDT-NC
SPDT-NO
SPDT
0.49 N {50 gf}
0.49 N {50 gf}
0.59 N {60 gf}
0.20 N {20 gf}
0.29 N {30 gf}
0.59 N {60 gf}
0.29 N {30 gf}
Short hinge lever
Hinge lever
SPDT-NC
SPDT-NO
SPDT
D
3
V
SPDT-NC
SPDT-NO
SPDT
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
1 mm
(F gap)
0.1 A
SPDT-NC
SPDT-NO
SPDT
SPDT-NC
SPDT-NO
SPDT
SPDT-NC
SPDT-NO
SPDT
SPDT-NC
SPDT-NO
Note. If you need mounting hole 2.9 mm, add "-K" at last of model.
Consult your OMRON sales representative when you can't find a model on this List of Models.
Contact Form
●SPDT
●SPST-NC
●SPST-NO
NC
NO
NC
NO
COM
COM
COM
Contact Specifications
Item
Model
D3V-21
D3V-16
D3V-11
D3V-6
D3V-01
Crossbar
Gold alloy
1.0 mm
Specification
Material
Rivet
Silver alloy
Contact
Gap (standard value)
0.5 mm
1.0 mm (F gap) or 0.5 mm (G gap)
NC
NO
Inrush current
50 A max.
40 A max.
24 A max.
15 A max.
---
Minimum applicable load (see note)
160 mA at 5 VDC
1 mA at 5 VDC
Note. For more information on the minimum applicable load, refer to Using Micro Loads on page 11.
5
D3V
Miniature Basic Switch
Ratings
Item
Resistive load
Model
Rated voltage
250 VAC
125 VDC
250 VDC
250 VAC
125 VDC
250 VDC
250 VAC
125 VDC
250 VDC
250 VAC
125 VDC
250 VDC
125 VAC
30 VDC
21 A
0.6 A
0.3 A
16 A
0.6 A
0.3 A
11 A
0.6 A
0.3 A
6 A
D3V-21
D3V-16
D3V-11
D
3
V
D3V-6
0.4 A
0.3 A
0.1 A
0.1 A
D3V-01
Note 1. The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current values of models with
a contact gap of 0.5 mm (gap G).
Note 2. The ratings values apply under the following test conditions:
Ambient temperature: 20 2°C
Ambient humidity: 65 5%
Operating frequency: 30 operations/min
Approved Safety Standards
Consult your OMRON sales representative for specific models with standard approvals.
UL1054 (File No. E41515)/CSA C22.2 No.55 (File No. LR21642)
Rated voltage
125 VAC
Model
D3V-21G
---
D3V-16
16 A, 1/2 HP
16 A, 1/2 HP
0.6 A
D3V-16G
16 A, 1/2 HP
16 A, 1/2 HP
0.1 A
D3V-11
11 A, 1/2 HP
11 A, 1/2 HP
0.6 A
D3V-11G
11 A, 1/2 HP
11 A, 1/2 HP
0.1 A
D3V-6
6 A, 1/4 HP
6 A, 1/4 HP
---
D3V-6G
6 A, 1/4 HP
6 A, 1/4 HP
---
D3V-01
0.1 A
---
250 VAC
125 VDC
250 VDC
20.1 A
---
---
---
0.3 A
---
0.3 A
---
---
---
---
EN 61058-1: 1992+A1: 1993 (License No. 40024894)
Rated voltage
125 VAC
250 VAC
Model
D3V-21G
---
D3V-16
---
D3V-11
D3V-6
---
D3V-01
---
0.1 A
---
20 (4) A
16 (3) A
11 (3) A
6 (2) A
Testing conditions: 5E4 (50,000 operations), T85 (0 to 85°C) for D3V-21/D3V-01, T105 (0 to 105°C) for D3V-16/D3V-11/D3V-6
Rated voltage
250 VAC
Model
D3V-21G
21 (8) A
Testing conditions: 10,000 operations, T85 (0 to 85°C)
6
D3V
Miniature Basic Switch
Characteristics
Item
Model
D3V-21
D3V-16
D3V-11
D3V-6
D3V-01
Permissible operating speed
0.1 mm to 1 m/s (pin plunger models)
Mechanical: 600 operations/min max.
Electrical: 30 operations/min max.
Permissible operating frequency
Insulation resistance
100 MΩ min. (at 500 VDC with insulation tester)
0.49N {50 gf}: 50 mΩ
max.
0.25N {25 gf}: 100 mΩ
max.
Contact resistance (initial values)
Dielectric strength (see note 2)
50 mΩ max.
30 mΩ max.
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
D
3
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and non-
V
current-carrying metal parts
Vibration resistance (see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 400 m/s2 {approx. 40 G} max.
Malfunction: 100 m/s2 {approx. 10 G} max.
Shock resistance (see note 3)
Mechanical
Durability (see note 4)
Electrical
10,000,000 operations min.
50,000 operations min. 100,000 operations min. 200,000 operations min.
500,000 operations min.
Degree of protection
IEC IP40
Degree of protection against electric shock
Proof tracking index (PTI)
Class I
250
–25 to +85°C
–25 to +85°C
(at ambient humidity
of 60% max.) (with no
icing or condensation)
–25 to +105°C (at ambient humidity of 60% max.)
(at ambient humidity
of 60% max.) (with no
icing or condensation)
Ambient operating temperature
(with no icing or condensation)
Ambient operating humidity
Weight
85% max. (for +5 to +35°C)
Approx. 6.2 g (pin plunger models)
Note 1. The data given above are initial values.
Note 2. The dielectric strength values shown in the table are for models with a Separator.
Note 3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models, they apply at the total travel
position.
Note 4. For testing conditions, contact your OMRON sales representative.
Terminals/Appearances (Unit: mm)
Solder Terminals
(A)
Quick-connect Terminals (#187)
(C2)
Quick-connect Terminals (#250)
(C)
(4.9)
(7.7)
(5.5)
(6.5)
(5.5)
(6.5)
3.2
2.9
2.9
(12.0)
(10)
t = 0.5
(10)
t = 0.5
t = 0.8
Three, quick-connect
terminals (#187)
Three, solder terminals
Three, quick-connect
terminals (#250)
6.35
8
3.2 (see note)
6.35
3.2
3.95
4.75 0.1
1.6 dia.
4.75 0.1
6.35 0.1
2.4 dia.
1.6-dia. terminal hole
Note: Indicates the length to the center of the
1.6-dia. holes
1.65-dia. terminal hole
Note. The table below is for the SPDT contact specifications. Two terminals will be available for SPST-NO or SPST-NC contact specifications. For terminal positions,
refer to Contact Form on page 5.
Mounting Holes (Unit: mm)
Two, 3.1-dia. mounting holes or
M3 screw holes
10.3 0.1
22.2 0.1
7
D3V
Miniature Basic Switch
Dimensions (Unit: mm) and Operating Characteristics
The following illustrations and drawings are for quick-connect terminals (#187) (terminals C2). D3V models incorporate terminals A and C. These models are different
from #187 models in terminal size only. Terminals A and C are omitted from the following drawings. Refer to "Terminals/Appearances" on page 7 for these terminals.
The @ in the model number is for the terminal code.
●Pin Plunger Models
A
D3V-21G-1C4A
D3V-16-1@5
D3V-11-1@5
D3V-11-1@4
D3V-6-1@4
D
3
V
D3V-6G-1@3
D3V-01-1@3
t=0.5
Three, quick-connect
terminals (#187)
Model
D3V-16-1@5
D3V-11-1@5
D3V-11-1@4
D3V-6-1@4
D3V-21G-1C4A
D3V-6G-1@3
D3V-01-1@3
Operating Characteristics
Operating Force
Releasing Force
OF Max.
RF Min.
1.23 N {125 gf}
0.20 N {20 gf}
1.96 N {200 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.15 N {15 gf}
0.49 N {50 gf}
0.05 N {5 gf}
Pretravel
Overtravel
Movement Differential MD Max.
PT Max.
OT Min.
1.2 mm
1.0 mm
0.3 mm
1.2 mm
1.0 mm
0.4 mm
1.2 mm
1.0 mm
0.3 mm
1.2 mm
1.0 mm
0.4 mm
Operating Position OP
14.7 0.4 mm
A
●Short Hinge Lever Models
D3V-21G1-1C4A
D3V-161-1@5
22.1
t=0.5
+0.13
2.85 4.2
3.1
dia. hole
1.6
−0.03
PT
8.1
0.7
4
2.8
D3V-111-1@5
OP
10.3 0.1
15.9
7.2
D3V-111-1@4
18.7
D3V-61-1@4
+0.13
3.1
−0.03
D3V-6G1-1@3
3.4 0.15 dia. hole
22.2 0.1
27.8
2.8
(10)
10.3
t=0.5
D3V-011-1@3
Three, #187 series tab
37.8 0.8
Model
D3V-161-1@5
D3V-111-1@5
D3V-111-1@4
D3V-61-1@4
D3V-21G1-1C4A
D3V-6G1-1@3
D3V-011-1@3
Operating Characteristics
Operating Force
Releasing Force
OF Max.
RF Min.
1.23 N {125 gf}
0.20 N {20 gf}
1.96 N {200 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.15 N {15 gf}
0.49 N {50 gf}
0.05 N {5 gf}
Pretravel
Overtravel
Movement Differential MD Max.
PT Max.
OT Min.
1.6 mm
0.8 mm
0.5 mm
1.6 mm
0.8 mm
0.6 mm
1.6 mm
0.8 mm
0.5 mm
1.6 mm
0.8 mm
0.6 mm
Operating Position OP
15.2 0.5 mm
●Hinge Lever Models
D3V-21G2-1C4A
D3V-162-1@5
A
35.6 0.8
2.85 4.2
+0.13
3.1
dia. hole
1.6
−0.03
t=0.5
PT
8.1
D3V-112-1@5
0.7
4
2.8
D3V-112-1@4
D3V-62-1@4
OP
10.3 0.1
7.2
15.9
18.8
D3V-6G2-1@3
D3V-012-1@3
+0.13
3.1
−0.03
3.4 0.15 dia. hole
22.2 0.1
27.8
10.3
2.8
(10)
t=0.5
Three, #187 series tab
37.8 0.8
Model
D3V-162-1@5
D3V-112-1@5
D3V-112-1@4
D3V-62-1@4
D3V-21G2-1C4A
D3V-6G2-1@3
D3V-012-1@3
Operating Characteristics
Operating Force
Releasing Force
OF Max.
RF Min.
0.78 N {80 gf}
0.06 N {6 gf}
1.23 N {125 gf}
0.14 N {14 gf}
0.59 N {60 gf}
0.06 N {6 gf}
0.29 N {30 gf}
---
Pretravel
Overtravel
Movement Differential MD Max.
PT Max.
OT Min.
4.0 mm
1.6 mm
0.8 mm
4.0 mm
1.6 mm
1.5 mm
4.0 mm
1.6 mm
0.8 mm
4.0 mm
1.6 mm
1.5 mm
Operating Position OP
15.2 1.2 mm
Note 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
8
D3V
Miniature Basic Switch
●Long Hinge Lever Models
D3V-21G3-1C4A
D3V-163-1@5
A
+0.13
59.4 0.8
t=0.5
3.1
dia. hole
−0.03
4.2
2.85
1.6
PT
8.1
0.7
4
D3V-113-1@5
2.8
D3V-113-1@4
OP
15.9
10.3 0.1
7.2
18.7
D3V-63-1@4
D3V-6G3-1@3
+0.13
−0.03
3.1
3.4 0.15 dia. hole
22.2 0.1
D3V-013-1@3
2.8
(10)
10.3
t=0.5
Three, #187 series tab
27.8
37.8 0.8
D
3
V
Model
D3V-163-1@5
D3V-113-1@5
D3V-113-1@4
D3V-63-1@4
D3V-21G3-1C4A
D3V-6G3-1@3
D3V-013-1@3
Operating Characteristics
Operating Force
Releasing Force
OF Max.
RF Min.
0.44 N {45 gf}
0.03 N {3 gf}
0.69 N {70 gf}
0.06 N {6 gf}
0.34 N {35 gf}
0.20 N {20 gf}
---
---
Pretravel
Overtravel
Movement Differential MD Max.
PT Max.
OT Min.
9.0 mm
2.0 mm
2.0 mm
9.0 mm
2.0 mm
2.8 mm
9.0 mm
3.2 mm
2.0 mm
9.0 mm
3.2 mm
2.8 mm
+2.6
Operating Position OP
15.2 2.6 mm
15.2
mm
−3.2
A
●Simulated Roller Lever Models
D3V-21G4-1C4A
D3V-164-1@5
32.5 0.8
t=0.5
2.85 4.2
+0.13
PT
3.1
−0.03
dia. hole
1.6
8.1
D3V-114-1@5
0.7
D3V-114-1@4
2.8
4
OP
D3V-64-1@4
10.3 0.1
15.9
7.2
18.8
D3V-6G4-1@3
D3V-014-1@3
+0.13
3.1
−0.03
3.4 0.15 dia. hole
2.8
(10)
10.3
t=0.5
Three, #187 series tab
22.2 0.1
27.8
37.8 0.8
Model
D3V-164-1@5
D3V-114-1@5
D3V-114-1@4
D3V-64-1@4
D3V-21G4-1C4A
D3V-6G4-1@3
D3V-014-1@3
Operating Characteristics
Operating Force
Releasing Force
OF Max.
RF Min.
0.83 N {85 gf}
0.07 N {7 gf}
1.23 N {125 gf}
0.14 N {14 gf}
0.59 N {60 gf}
0.06 N {6 gf}
0.29 N {30 gf}
---
Pretravel
Overtravel
Movement Differential MD Max.
PT Max.
OT Min.
4.0 mm
1.6 mm
1.4 mm
4.0 mm
1.6 mm
1.5 mm
4.0 mm
1.6 mm
1.4 mm
4.0 mm
1.6 mm
1.5 mm
Operating Position OP
18.7 1.2 mm
●Short Hinge Roller Lever Models
D3V-21G5-1C4A
D3V-165-1@5
A
20.1 0.8
5.1
PT
+0.13
3.1
−0.03
dia. hole
1.6
4.8
t=0.5
D3V-115-1@5
8.1
0.7
4
D3V-115-1@4
2.8
OP
10.3 0.1
D3V-65-1@4
15.9
7.2
18.8
D3V-6G5-1@3
D3V-015-1@3
+0.13
3.1
−0.03
3.4 0.15 dia. hole
2.8
22.2 0.1
27.8
37.8 0.8
t=0.5
Three, #187 series tab
10.3
(10)
Model
D3V-165-1@5
D3V-115-1@5
D3V-115-1@4
D3V-65-1@4
D3V-21G5-1C4A
D3V-6G5-1@3
D3V-015-1@3
Operating Characteristics
Operating Force
Releasing Force
OF Max.
RF Min.
1.42 N {145 gf}
0.2 N {20 gf}
2.35 N {240 gf}
0.49 N {50 gf}
1.18 N {120 gf}
0.15 N {15 gf}
0.59 N {60 gf}
0.06 N {6 gf}
Pretravel
Overtravel
Movement Differential MD Max.
PT Max.
OT Min.
1.6 mm
0.8 mm
0.5 mm
1.6 mm
0.8 mm
0.6 mm
1.6 mm
0.8 mm
0.5 mm
1.6 mm
0.8 mm
0.6 mm
Operating Position OP
20.7 0.6 mm
Note 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
9
D3V
Miniature Basic Switch
●Hinge Roller Lever Models
D3V-21G6-1C4A
D3V-166-1@5
A
5.1
PT
33.0 0.8
t=0.5
+0.13
3.1
−0.03
dia. hole
1.6
4.8
D3V-116-1@5
8.1
0.7
D3V-116-1@4
2.8
OP
4
D3V-66-1@4
10.3 0.1
15.9
7.2
18.7
D3V-6G6-1@3
+0.13
D3V-016-1@3
3.1
−0.03
3.4 0.15 dia. hole
2.8
(10)
10.3
t=0.5
22.2 0.1
27.8
Three, #187 series tab
D
3
V
37.8 0.8
Model
D3V-166-1@5
D3V-116-1@5
D3V-116-1@4
D3V-66-1@4
D3V-21G6-1C4A
D3V-6G6-1@3
D3V-016-1@3
Operating Characteristics
Operating Force
Releasing Force
OF Max.
RF Min.
0.79 N {80 gf}
0.05 N {5 gf}
1.23 N {125 gf}
0.14 N {14 gf}
0.59 N {60 gf}
0.06 N {6 gf}
0.29 N {30 gf}
---
Pretravel
Overtravel
Movement Differential MD Max.
PT Max.
OT Min.
4.0 mm
1.6 mm
0.8 mm
4.0 mm
1.6 mm
1.5 mm
4.0 mm
1.6 mm
0.8 mm
4.0 mm
1.6 mm
1.5 mm
Operating Position OP
20.7 1.2 mm
Note 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
10
D3V
Miniature Basic Switch
Precautions
★Please refer to "Common Precautions" for correct use.
Cautions
●Handling
Be careful not to drop the switch. Doing so may cause damage to
the switch's internal components because it is designed for a
small load.
Correct Use
D
3
V
●Mounting
●Using Micro Loads
Use two M3 mounting screws with an appropriate screwdriver to
mount the switch. Tighten the screws to a torque of 0.39 to 0.59
N·m {4 to 6 kgf·cm}.
Using a model for ordinary loads to open or close the contact of
a micro load circuit may result faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the operating range shown below, if inrush
current occurs when the contact is opened or closed, it may
increase contact wear and so decrease durability. Therefore,
insert a contact protection circuit where necessary.
●Mounting Direction
Mount lever-operated switches with a maximum operating force
of 0.49 N in a direction where the actuator weight will not be
applied to the switch. Since the switch is designed for a small
load, its resetting force is small. Therefore, resetting failure may
occur if unnecessary load is applied to the switch.
The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level of 60% (λ 60). The equation, λ 60 = 0.5 × 10-6/operations
indicates that the estimated malfunction rate is less than
1/2,000,000 operations with a reliability level of 60%.
●Insulation Distance
According to EN61058-1, the minimum insulation thickness for
this switch should be 1.1 mm and minimum clearance distance
between the terminal and mounting plate should be 1.9 mm. If
the insulation distance cannot be provided in the product
incorporating the switch, either use a switch with insulation
barrier or use a Separator to ensure sufficient insulation
distance.
Operating
range for
Operating range
general-
for micro load
load models
models D3V-01
Inoperable
range
Current (mA)
●Solder Terminal Approval Conditions
Soldering iron can be used.
Soldering hook hole available.
Soldering terminal types 1 and 2 are met.
Actuator (Sold Separately)
Various Actuators are available as shown on D3V/V/VX/D2MV/D2RV Common Accessories.
Connector (Sold Separately)
Refer to Terminal Connectors.
11
D3V
Miniature Basic Switch
D
3
V
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No.B103-E1-05
0815(0207)(O)
12
相关型号:
D3V-011M-1C23-K
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 8VDC, 2.4mm, Quick Connect Terminal, Short Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012-1A3
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012-1A3-K
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012-1C23
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012-1C23-K
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012-1C3
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012-2C23-K
Snap Acting/Limit Switch, SPST, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012-3A3
Snap Acting/Limit Switch, SPST, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012-3C23
Snap Acting/Limit Switch, SPST, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012M-1A3
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012M-1C23
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
D3V-012M-1C23-K
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Lever Actuator, Panel Mount, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明