D4F-402-3D [OMRON]

Snap Acting/Limit Switch;
D4F-402-3D
型号: D4F-402-3D
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap Acting/Limit Switch

文件: 总8页 (文件大小:1824K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Small Safety Limit Switch  
D4F  
CSM_D4F_DS_E_3_1  
Note: Contact your sales representative for details on  
models with safety standard certification.  
Smallest Class of Safety Limit Switches in  
the World  
• The world's smallest limit switch with a direct opening  
mechanism (four-contact construction model).  
• High-sensitivity safety limit switch.  
• Built-in switches with two- or four-contact construction are  
available.  
• Degree of protection: IP67 (EN60947-5-1)  
• Certified standards: UL, EN (TÜV), and CCC  
Be sure to read the “Safety Precautions” on page 6  
and the “Precautions for All Safety Limit Switches” .  
Model Number Structure  
Model Number Legend  
D4F-@@-@@  
1 2 3 4  
1. Built-in Switch  
1: 1NC/1NO (slow-action)  
2: 2NC (slow-action)  
3: 2NC/2NO (slow-action)  
4: 4NC (slow-action)  
2. Actuator  
3. Cable Length  
1: 1 m  
3: 3 m  
5: 5 m  
4. Pull-outing direction of cable  
R: Horizontal  
D: Vertical  
02: Roller plunger  
(Metal roller)  
20: Roller lever  
(Metal lever, resin roller)  
Ordering Information  
List of Models  
Safety Limit Switches (with Direct Opening Mechanism)  
Consult with your OMRON representative when ordering any models that are not listed in this table.  
Built-in switch  
1NC/1NO  
2NC  
2NC/2NO  
4NC  
Cable  
Pull-outing  
Actuator  
(slow-action)  
(slow-action)  
(slow-action)  
(slow-action)  
length direction of cable  
Direct  
opening  
Direct  
opening  
Direct  
opening  
Direct  
opening  
Model  
Model  
Model  
Model  
Horizontal  
D4F-120-1R  
D4F-120-1D  
D4F-120-3R  
D4F-120-3D  
D4F-120-5R  
D4F-120-5D  
D4F-102-1R  
D4F-102-1D  
D4F-102-3R  
D4F-102-3D  
D4F-102-5R  
D4F-102-5D  
D4F-220-1R  
D4F-220-1D  
D4F-220-3R  
D4F-220-3D  
D4F-220-5R  
D4F-220-5D  
D4F-202-1R  
D4F-202-1D  
D4F-202-3R  
D4F-202-3D  
D4F-202-5R  
D4F-202-5D  
D4F-320-1R  
D4F-320-1D  
D4F-320-3R  
D4F-320-3D  
D4F-320-5R  
D4F-320-5D  
D4F-302-1R  
D4F-302-1D  
D4F-302-3R  
D4F-302-3D  
D4F-302-5R  
D4F-302-5D  
D4F-420-1R  
D4F-420-1D  
D4F-420-3R  
D4F-420-3D  
D4F-420-5R  
D4F-420-5D  
D4F-402-1R  
D4F-402-1D  
D4F-402-3R  
D4F-402-3D  
D4F-402-5R  
D4F-402-5D  
1 m  
Roller lever  
(Metal lever,  
resin roller)  
Vertical  
Horizontal  
3 m  
Vertical  
Horizontal  
5 m  
Vertical  
Horizontal  
Roller  
plunger  
(Metal roller)  
1 m  
Vertical  
Horizontal  
3 m  
Vertical  
Horizontal  
5 m  
Vertical  
1
D4F  
Specifications  
Standards and EC Directives  
Conforms to the following EC Directives:  
Certified Standard Ratings  
TÜV (EN60947-5-1), CCC (GB14048.5)  
Machinery Directive  
Low Voltage Directive  
EN60204-1  
EN1088  
Item  
Utilization category  
AC-15  
DC-13  
0.27 A  
250 V  
Rated operating current (Ie) 0.75 A  
Rated operating voltage (Ue) 240 V  
EN50047  
EN81  
EN115  
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a  
short-circuit protection device.  
GS-ET-15  
JIS C 8201-5-1  
UL/CSA (UL508, CSA C22.2 No. 14)  
C300  
Current (A)  
Make Break  
Volt-amperes (VA)  
Make Break  
Rated  
Certified Standards  
Carry current  
voltage  
Certification body  
Standards  
File No.  
120 VAC  
240 VAC  
15  
1.5  
0.75  
EN60947-5-1  
(certified direct opening)  
2.5 A  
1,800 180  
TÜV SÜD  
*1  
7.5  
UL508  
CSA C22.2 No.14  
Q300  
UL *2  
E76675  
Current (A)  
Volt-amperes (VA)  
Make Break  
Rated  
20030103050  
64266  
Carry current  
CQC (CCC) *3  
GB14048.5  
voltage  
Make  
Break  
0.55  
0.27  
*1. Contact your OMRON sales representative.  
125 VDC  
250 VDC  
0.55  
0.27  
2.5 A  
69 69  
*2. Certification has been obtained for CSA C22.2 No. 14 under UL.  
*3. Ask your OMRON representative for information on certified  
models.  
2
D4F  
Characteristics  
Degree of protection *1  
IP67 (EN60947-5-1)  
10,000,000 times min.  
Mechanical  
Durability *2  
1,000,000 times min. (4 mA resistive load at 24 VDC, 4 circuits)  
150,000 times min. (1 A resistive load at 125 VAC, 2 circuits/4 mA resistive load at 24 VDC, 2 circuits) *3  
Electrical  
Operating speed  
1 mm/s to 0.5 m/s  
Mechanical  
Electrical  
120 operations/minute  
Operating frequency  
Contact resistance *5  
30 operations/minute  
300 mΩ max. (with 1 m cable), 500 mΩ max. (with 3 m cable), 700 mΩ max. (with 5 m cable)  
Minimum applicable load *4  
Rated insulation voltage (Ui)  
Rated frequency  
4 mA resistive load at 24 VDC, 4 circuits (N-level reference value)  
250 V  
50/60 Hz  
Protection against electric shock  
Pollution degree (operating environment)  
Class I (with a ground wire)  
3 (EN60947-5-1)  
Between terminals  
of same polarity  
2.5 kV  
4 kV  
Impulse withstand  
voltage (EN60947-5-1)  
Between terminals  
of different polarity  
Between each  
terminal and ground  
4 kV  
100 MΩ min. (at 500 VDC) between terminals of the same polarities, between terminals of different polarities,  
between current-carrying metal parts and grounds, and between each terminal and non-current carrying metal parts  
Insulation resistance  
Contact gap  
2 × 2 mm min.  
Vibration resistance  
Malfunction  
Destruction  
Malfunction  
10 to 55 Hz, 0.75 mm single amplitude  
1,000 m/s2 min.  
300 m/s2 min.  
Shock resistance  
Conditional short-circuit current  
Conventional free air thermal current (Ith)  
Ambient operating temperature  
Ambient operating humidity  
Cable  
100 A (EN60947-5-1)  
2.5 A (EN60947-5-1)  
30 to 70°C (with no icing)  
95% max.  
UL2464 No. 22 AWG, finishing O.D.: 8.3 mm  
Approx. 190 g (D4F-102-1R, with 1 m cable)  
Approx. 220 g (D4F-120-1R, with 1 m cable)  
Weight  
Note: 1. The above values are initial values.  
2. Once the contact is opened or closed with an ordinary load, it cannot be used for a load smaller than that. The contact surface may be  
rough, which impairs the reliability of contacting.  
*1. The degree of protection shown above is based on the test method specified in EN60947-5-1. Be sure to confirm in advance the sealing  
performance under the actual operating environment and conditions.  
*2. Durability values are calculated at an operating temperature of 5 to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON  
sales representative for more detailed information on other operating environments.  
*3. Do not apply 1 A at 125 VAC to more than two circuits.  
*4. The value will vary depending on factors such as the switching frequency, the ambient environment, and the reliability level.  
Be sure to confirm correct operation with the actual load before application.  
*5. The contact resistance was measured with 0.1 A at 5 to 8 VDC with a fall-of-potential method.  
3
D4F  
Structure and Nomenclature  
Structure  
Head  
Lever  
The plunger type of actuator can be used in a  
normal direction and reverse direction.  
Improved safety of the lever-setting (Form lock configuration).  
Many grooves are incised on the lever and the rotating shaft  
that mesh with each other to prevent a slip between the lever  
and the rotating shaft.  
The lever can be set for positioning in steps of 9 degrees.  
Cable  
The cable can be pulled out in a horizontal  
direction or in a vertical direction.  
Built-in Switch  
Has a direct opening mechanism separating  
the contacts when the NC contacts are welded.  
Direct Opening Mechanism  
1NC/1NO Contact (slow-action)  
Fixed contact (NC)  
Contact spring  
Movable contact  
Fixed contact (NO)  
Return spring  
Plunger  
Conforms to EN60947-5-1 Direct Opening  
.
(Only the NC contacts have a direct opening function.)  
When contact welding occurs, the NC contacts are separated from  
each other by pushing in the plunger.  
Contact Form  
Model  
Contact  
Contact form  
Operating pattern  
Remarks  
Only NC contact 11-12 has a certified  
direct opening mechanism.  
Zb  
11-12  
33-34  
1NC/1NO  
(slow-action)  
ON  
ON  
11  
33  
12  
34  
D4F-1@-@@  
The terminals 11-12 and 33-34 can be  
used as unlike poles.  
Stroke  
NC contacts 11-12 and 21-22 have a  
certified direct opening mechanism.  
Zb  
Zb  
11-12  
21-22  
2NC  
(slow-action)  
11  
21  
12  
22  
D4F-2@-@@  
D4F-3@-@@  
The terminals 11-12 and 21-22 can be  
used as unlike poles.  
Stroke  
11-12  
21-22  
33-34  
43-44  
NC contacts 11-12 and 21-22 have a  
certified direct opening mechanism.  
11  
21  
33  
43  
12  
22  
34  
44  
2NC/2NO  
(slow-action)  
ON  
ON  
The terminals 11-12, 21-22, 33-34 and  
43-44 can be used as unlike poles.  
Stroke  
Stroke  
NC contacts 11-12, 21-22, 31-32 and 41-  
42 have a certified direct opening  
mechanism.  
Zb  
11-12  
21-22  
31-32  
41-42  
11  
21  
31  
41  
12  
22  
32  
42  
4NC  
(slow-action)  
D4F-4@-@@  
The terminals 11-12, 21-22, 31-32 and  
41-42 can be used as unlike poles.  
Note: Terminal numbers are according to EN50013; contact symbols are according to IEC60947-5-1.  
4
D4F  
Dimensions and Operating Characteristics  
(Unit: mm)  
Roller lever (Metal lever, resin roller)  
D4F-@20-@R  
Roller plunger (Metal roller)  
D4F-@02-@R  
(30.8)  
25.5  
9
17.5-dia. × 6.8,  
resin roller  
Pretravel  
12-dia. × 4.4,  
Sintered stainless steel roller  
24.7R  
Operating  
position  
Two, 4.4-dia.  
8-dia. countersinking,  
depth 4  
30  
Two, 4.4-dia.  
8-dia. countersinking,  
depth 4  
27.5  
18.5  
8.8  
(14.4-dia.)  
(35)  
0.1  
(14.4-dia.)  
(35)  
20  
0.1  
20  
(42.7)  
(42.7)  
18  
30  
30  
18  
(11.4)  
UL2464  
No. 22 AWG,  
(11.4)  
UL2464  
No. 22 AWG,  
finishing O.D.: 8.3 mm  
finishing O.D.: 8.3 mm  
Roller lever (Metal lever, resin roller)  
D4F-@20-@D  
Roller plunger (Metal roller)  
D4F-@02-@D  
(30.8)  
25.5  
17.5-dia. × 6.8,  
resin roller  
9
Pretravel  
12-dia. × 4.4,  
Sintered stainless steel roller  
24.7R  
Operating  
30  
Two, 4.4-dia.  
8-dia. countersinking,  
depth 4  
Two, 4.4-dia.  
8-dia. countersinking,  
depth 4  
position  
27.5  
18.5  
8.8  
0.1  
20  
0.1  
20  
(42.7)  
(7.9)  
(42.7)  
(16.7)  
(16.7)  
(7.9)  
UL2464  
No. 22 AWG,  
finishing O.D.: 8.3 mm  
UL2464  
No. 22 AWG,  
finishing O.D.: 8.3 mm  
(17.6)  
30  
18  
(17.6)  
30  
18  
2
2
Note: Each dimension has a tolerance of 0.4 mm unless otherwise specified.  
Slow-action (1NC/1NO), (2NC), (2NC/2NO), and (4NC)  
Model  
D4F-@20-@R  
D4F-@20-@D  
D4F-@02-@R  
D4F-@02-@D  
Operating Characteristics  
Operating force  
Release force  
Pretravel  
OF max. *1  
RF min. *2  
PT1 (11-12 and 21-22) 6 3° (NC)  
PT1 (31-32 and 41-42) 9 3° (NC)  
PT2 *3  
5 N  
0.5 N  
12 N  
1.5 N  
1 mm max. (NC)  
1.3 mm max. (NC)  
(1.2 mm) (NO)  
(12°) (NO)  
Overtravel  
OT min.  
40°  
3.2 mm  
Operating position  
OP (11-12 and 21-22) ---  
OP (31-32 and 41-42) ---  
29.4 1 mm  
29 1 mm  
Total travel  
TT *3  
(55°)  
(4.5 mm)  
1.8 mm  
20 N  
Direct opening travel DOT min. *4  
Direct opening force DOF min.  
18°  
20 N  
Note: Variation occurs in the simultaneity of contact opening/closing operations of 2NC, 2NC/2NO, and 4NC contacts.  
Check contact operation.  
*1. The OF value is the maximum load that opens an NC contact (11-12, 21-22, 31-32, 41-42).  
*2. The RF value is the minimum load that closes an NC contact (11-12, 21-22, 31-32, 41-42).  
*3. The PT2 and TT values are reference values.  
*4. The D4F is used in accordance with EN81 and EN115 at a minimum DOT of 30° and 2.8 mm.  
5
D4F  
Safety Precautions  
Refer to the “Precautions for All Switches” and “Precautions for All Safety Limit Switches” .  
Precautions for Safe Use  
Precautions for Correct Use  
Do not use more than one D4F side-by-side.  
Do not switch circuits for two or more standard loads (250 VAC,  
3 A). Doing so may adversely affect insulation performance.  
The Switch contacts can be used with either standard loads or  
microloads. Once the contacts have been used to switch a load,  
however, they cannot be used to switch smaller loads. The contact  
surfaces will become rough once they have been used and contact  
reliability for smaller loads may be reduced.  
Handling of Cables  
Cables cannot be flexed repeatedly.  
Appropriate Tightening Torque  
Be sure to tighten each screw of the D4F properly, otherwise the D4F  
may soon malfunction  
The cable is fixed with sealing materials on the bottom of the  
switch. When excessive force may be imposed on the cable, fasten  
the cable with a fixing unit at a distance of 50 mm from the bottom  
of the switch as shown.  
Do not pull or press the cable at an excessive force (50 N max.).  
When bending the cable, secure the cable with more than 45 mm  
bending radius so as not to cause damage to the insulator or  
sheath of the cable. Doing so may result in current leakage or  
burning.  
.
No.  
Type  
Appropriate tightening torque  
1
Lever mounting screw (M5) 2.4 to 2.8 N·m  
Body mounting screw (M4) 1.18 to 1.37 N·m  
2
1
2
Bending radius:  
45 mm min.  
50 mm  
Fixing unit  
When wiring, be sure to prevent penetration of a liquid such as  
water or oil through the cable end.  
Mounting  
Use two M4 screws and washers to mount the D4F securely. The D4F  
can be mounted more securely with proper tightening torque.  
Operating Environment  
Do not use the Switch submersed in oil or water or in locations  
continuously subject to splashes of oil or water. Doing so may  
result in oil or water entering the Switch. (The IP67 degree of  
protection of the Switch specifies the amount of water penetration  
after the Switch is submerged in water for a certain period of time.)  
Mounting Holes (Unit: mm)  
Two, 4.2-dia. or M4 screw hole  
0.1  
20  
Changing the Lever Angle  
Unfasten the screw that holds the lever to set the position of the  
lever at any angle through 360° (in steps of 9°).  
After unfastening the screws that hold the lever, mount the lever  
the other way (normal side or reverse side). Set an angle of the  
lever to complete adjustment within a range in which the lever does  
not touch the switch body.  
6
D4F  
Wiring  
Identifying Wires  
Identify wires according to the color (with or without white lines) of the  
insulation on the wire.  
Operating  
To set the plunger stroke correctly, press-fit the plunger until the  
top of the pushing surface comes between two grooves on the  
plunger.  
Core Insulator Colors  
Blue/white, Orange/white,  
Pink/white, Brown/white,  
Green/yellow, Brown, Pink,  
Orange, and Blue  
Cross section  
Pushing surface  
Proper range  
Insulation  
1
3
9
2
8
7
Grooves  
4
6
5
External insulation sheath  
Example: Blue/white is a blue  
insulator with a white line.  
Dummy insulator (black)  
To set the roller lever stroke correctly, push the dog and cam until  
the lance point comes within the range of the convex part that is the  
correct setting position.  
Terminal Numbers  
Identify terminal numbers based on the color (with or without white  
lines) of the insulation on the wire.  
The safety and auxiliary contacts of D4F models of four-terminal  
contact construction and those of two-terminal contact  
construction are described below.  
Convex part  
Lance point  
Proper range  
The safety contacts are direct-opening NC contacts (11-12 and 21-  
22); they are used for safety circuits, and each of them is indicated  
with the appropriate mark  
.
Auxiliary contacts are used to check (to monitor) the operating  
state of the switch, which are equivalent to NO contacts (33-34 and  
43-44) or NC contacts (31-32 and 41-42).  
The NC contacts 31-32 and 41-42 of auxiliary contacts (orange or  
pink) can be used as safety contacts.  
Others  
Actuating the switch from an angle other than 90 degrees to the  
switch face may deform or damage the actuator, or deform or  
damage the rotary spindle, so make sure that the dog is straight.  
Dog  
Incorrect  
Correct  
Dog  
<1NC/1NO>  
Zb  
Safety contact Blue 11  
Auxiliary contact Orange 33  
Green/yellow ground  
12 Blue/white  
34 Orange/white  
Dog  
Incorrect  
Correct  
Dog  
<2NC>  
Zb  
Safety contact Blue 11  
Auxiliary contact Brown 21  
Green/yellow ground  
12 Blue/white  
22 Brown/white  
<2NC/2NO>  
Do not remove the head. Otherwise, a failure may occur.  
To avoid telegraphing, take the following precautions.  
Zb  
Safety contact Blue 11  
Safety contact Brown 21  
Auxiliary contact Orange 33  
Auxiliary contact Pink 43  
Green/yellow ground  
12 Blue/white  
22 Brown/white  
34 Orange/white  
44 Pink/white  
1. Modify the rear end of the dog to an angle of 15° to 30° as  
shown below or to a secondary-degree curve.  
θ
θ
θ≥30°  
15°θ≤30°  
2. Modify the circuit so as not to detect the wrong operating  
signals.  
<4NC>  
Zb  
Safety contact Blue 11  
Safety contact Brown 21  
Auxiliary contact Orange 31  
Auxiliary contact Pink 41  
Green/yellow ground  
12 Blue/white  
22 Brown/white  
32 Orange/white  
42 Pink/white  
Note: Safety Contacts:  
The safety contacts are direct opening contacts certified by EN  
and each of them is indicated with the mark  
.
Cut the dummy core insulator and all unused wires at the end of  
the external insulation sheath when wiring the cable.  
7
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2009.3  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2009 All Right Reserved.  

相关型号:

D4F-420-3D

Snap Acting/Limit Switch
OMRON

D4F-420-5R

Snap Acting/Limit Switch
OMRON

D4F60

General Purpose Rectifiers(600V 4A)
SHINDENGEN

D4F60-5063

600V 4A
SHINDENGEN

D4FAU

Audio/RCA Connector,
SWITCH

D4FBAU

Audio/RCA Connector, 4 Pole(s), Printed Wiring Pin and Solid Lead Terminal, Receptacle,
SWITCH

D4FBSAU

Audio/RCA Connector,
SWITCH

D4FBXAU

Circular Connector,
SWITCH

D4FBXS

Circular Connector,
SWITCH

D4FDBAU

Audio/RCA Connector,
SWITCH

D4FS

Audio/RCA Connector, 4 Pole(s), Solid Lead Terminal,
SWITCH

D4G

1.0A GLASS PASSIVATED RECTIFIER
DIODES