D4GL-4GDA-A4-NPT [OMRON]

SWITCH SAFETY 3PST 750MA 240V;
D4GL-4GDA-A4-NPT
型号: D4GL-4GDA-A4-NPT
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

SWITCH SAFETY 3PST 750MA 240V

文件: 总20页 (文件大小:7191K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DGua4rd GLockLSa/fDety-4dooGr SwLitc-hS/SlidKe k1ey 0-LK@  
CSM_D4GL_D4GL-SK10-LK_DS_E_6_1  
Vertically Mounting Guard Lock  
Safety-door Switch Ideal for Limited  
Installation Space  
<Guard Lock Safety-door Switch D4GL>  
• Selectable Operation Key insertion direction.  
• Slim safety-door switch with an electromagnetic lock or  
unlock mechanism .  
• Built-in switches with multiple-contact construction are  
available.  
• A key holding force of 1,000 N minimum.  
• Can be used for either standard loads or microloads.  
• Lineup includes models with a conduit size of M20.  
• Variety of Metallic Heads Available.  
Guard Lock  
Safety-door Switches  
Slide keys  
For the most recent information on models that have been certified for  
safety standards, refer to your OMRON website.  
<Slide key D4GL-SK10-LK@>  
• The D4GL Vertical Electromagnetic Lock and Safety-door  
Switches easily mount to a 40 × 40-mm aluminum frame section.  
• The Switches are made of resin so they are suitable for lightweight doors.  
Be sure to read the “Safety Precautions” on page 17 and  
the “Precautions for All Safety Door Switches”.  
Model Number Structure  
Model Number Legend  
Switch (Standard type)  
Switch (Metallic release key type)  
D4GL-@@@@-@@-SJ  
D4GL-@@@@-@@  
1 2 3 4 5 6  
1 2 3 4 5 6  
1. Conduit Size  
1: Pg13.5  
1. Conduit Size  
2: G1/2 (1-conduit)  
2: G1/2  
4: M20 (1-conduit)  
4: M20  
2. Built-in Switch  
A: 1NC/1NO + 1NC/1NO  
B: 1NC/1NO + 2NC  
2. Built-in Switch (with Door Open/Closed Detection Switch and  
Lock Monitor Switch Contacts)  
A: 1NC/1NO (slow-action contacts) + 1NC/1NO (slow-action  
contacts)  
C: 2NC + 1NC/1NO  
D: 2NC + 2NC  
B: 1NC/1NO (slow-action contacts) + 2NC (slow-action contacts)  
C: 2NC (slow-action contacts) + 1NC/1NO (slow-action contacts)  
D: 2NC (slow-action contacts) + 2NC (slow-action contacts)  
E: 2NC/1NO (slow-action contacts) + 1NC/1NO (slow-action  
contacts)  
F: 2NC/1NO (slow-action contacts) + 2NC (slow-action contacts)  
G: 3NC (slow-action contacts) + 1NC/1NO (slow-action contacts)  
H: 3NC (slow-action contacts) + 2NC (slow-action contacts)  
3. Head Mounting Direction and Material  
F: Four mounting directions possible (Front-side mounting at  
shipping)/plastic  
D: Four mounting directions possible (Front-side mounting at  
shipping)/metal  
4. Door Lock and Release  
A: Mechanical lock/24 VDC solenoid release  
G: 24 VDC solenoid lock/mechanical release  
5. Indicator  
E: 2NC/1NO + 1NC/1NO  
F: 2NC/1NO + 2NC  
G: 3NC + 1NC/1NO  
H: 3NC + 2NC  
3. Head Material  
F: resin  
4. Door Lock and Release  
A: Mechanical lock/24 VDC solenoid release  
G: 24 VDC solenoid lock/ mechanical release  
5. Indicator  
A: 24 VDC (orange/green LED indicator)  
Note: The wiring specification is different from the wiring  
specification for the standard type.  
Please refer to the "Connection" section for details.  
6. Release Key Type  
Blank: Standard release key (metal)  
Operation Key  
A: 24 VDC (orange/green LED indicator)  
6. Release Key Type  
Blank: Standard release key (resin)  
D4DS-K@  
1
4:  
Special release key (resin)  
(Note: Release keys are provided.)  
1. Operation Key Type  
1: Horizontal mounting  
2: Vertical mounting  
3: Adjustable mounting (horizontal)  
5: Adjustable mounting (horizontal/vertical)  
1
D4GL/D4GL-SK10-LK@  
Ordering Information  
List of Models  
Switches (Operation Keys are sold separately.)  
: Models with certified direct opening contacts.  
Consult with your OMRON representative when ordering any models that are not listed in this table.  
Contact configuration  
(door open/closed  
detection switch and lock  
monitor switch contacts)  
(slow-action)  
Head  
material  
Release  
key type  
Solenoid voltage/  
indicator  
Lock and release  
types  
Conduit size  
Model  
Certified direct opening  
NC contact  
Pg13.5  
G1/2  
D4GL-1AFA-A  
D4GL-2AFA-A *  
D4GL-4AFA-A  
D4GL-1BFA-A  
D4GL-2BFA-A  
D4GL-4BFA-A  
D4GL-1CFA-A  
D4GL-2CFA-A  
D4GL-4CFA-A  
D4GL-1DFA-A  
D4GL-2DFA-A *  
D4GL-4DFA-A  
D4GL-1EFA-A  
D4GL-2EFA-A  
D4GL-4EFA-A  
D4GL-1FFA-A  
D4GL-2FFA-A *  
D4GL-4FFA-A  
D4GL-1GFA-A  
D4GL-2GFA-A  
D4GL-4GFA-A  
D4GL-1HFA-A  
D4GL-2HFA-A *  
D4GL-4HFA-A  
D4GL-1AFG-A  
D4GL-2AFG-A *  
D4GL-4AFG-A  
D4GL-1BFG-A  
D4GL-2BFG-A  
D4GL-4BFG-A  
D4GL-1CFG-A  
D4GL-2CFG-A  
D4GL-4CFG-A  
D4GL-1DFG-A  
D4GL-2DFG-A *  
D4GL-4DFG-A  
D4GL-1EFG-A  
D4GL-2EFG-A  
D4GL-4EFG-A  
D4GL-1FFG-A  
D4GL-2FFG-A *  
D4GL-4FFG-A  
D4GL-1GFG-A  
D4GL-2GFG-A  
D4GL-4GFG-A  
D4GL-1HFG-A  
D4GL-2HFG-A *  
D4GL-4HFG-A  
1NC/1NO+1NC/1NO  
1NC/1NO+2NC  
2NC+1NC/1NO  
2NC+2NC  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Mechanical lock  
Solenoid release  
Pg13.5  
G1/2  
2NC/1NO+1NC/1NO  
2NC/1NO+2NC  
3NC+1NC/1NO  
3NC+2NC  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
Solenoid: 24 VDC  
Orange/green LED:  
24 VDC  
M20  
Standard  
(resin)  
Plastic  
Pg13.5  
G1/2  
1NC/1NO+1NC/1NO  
1NC/1NO+2NC  
2NC+1NC/1NO  
2NC+2NC  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Solenoid lock  
Mechanical release  
Pg13.5  
G1/2  
2NC/1NO+1NC/1NO  
2NC/1NO+2NC  
3NC+1NC/1NO  
3NC+2NC  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
* Models with Korean S-mark certification.  
2
D4GL/D4GL-SK10-LK@  
Contact configuration  
(door open/closed  
detection switch and lock  
monitor switch contacts)  
(slow-action)  
Head  
material  
Release  
key type  
Solenoid voltage/  
indicator  
Lock and release  
types  
Conduit size  
Model  
Certified direct opening  
NC contact  
Pg13.5  
G1/2  
D4GL-1AFA-A4  
D4GL-2AFA-A4  
D4GL-4AFA-A4  
D4GL-1BFA-A4  
D4GL-2BFA-A4  
D4GL-4BFA-A4  
D4GL-1CFA-A4  
D4GL-2CFA-A4  
D4GL-4CFA-A4  
D4GL-1DFA-A4  
D4GL-2DFA-A4  
D4GL-4DFA-A4  
D4GL-1EFA-A4  
D4GL-2EFA-A4  
D4GL-4EFA-A4  
D4GL-1FFA-A4  
D4GL-2FFA-A4  
D4GL-4FFA-A4  
D4GL-1GFA-A4  
D4GL-2GFA-A4  
D4GL-4GFA-A4  
D4GL-1HFA-A4  
D4GL-2HFA-A4  
D4GL-4HFA-A4  
D4GL-1AFG-A4  
D4GL-2AFG-A4  
D4GL-4AFG-A4  
D4GL-1BFG-A4  
D4GL-2BFG-A4  
D4GL-4BFG-A4  
D4GL-1CFG-A4  
D4GL-2CFG-A4  
D4GL-4CFG-A4  
D4GL-1DFG-A4  
D4GL-2DFG-A4  
D4GL-4DFG-A4  
D4GL-1EFG-A4  
D4GL-2EFG-A4  
D4GL-4EFG-A4  
D4GL-1FFG-A4  
D4GL-2FFG-A4  
D4GL-4FFG-A4  
D4GL-1GFG-A4  
D4GL-2GFG-A4  
D4GL-4GFG-A4  
D4GL-1HFG-A4  
D4GL-2HFG-A4  
D4GL-4HFG-A4  
1NC/1NO+1NC/1NO  
1NC/1NO+2NC  
2NC+1NC/1NO  
2NC+2NC  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Mechanical lock  
Solenoid release  
Pg13.5  
G1/2  
2NC/1NO+1NC/1NO  
2NC/1NO+2NC  
3NC+1NC/1NO  
3NC+2NC  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
Special  
release  
key  
Solenoid: 24 VDC  
Orange/green LED:  
24 VDC  
M20  
Plastic  
Pg13.5  
G1/2  
(resin)  
1NC/1NO+1NC/1NO  
1NC/1NO+2NC  
2NC+1NC/1NO  
2NC+2NC  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Solenoid lock  
Mechanical release  
Pg13.5  
G1/2  
2NC/1NO+1NC/1NO  
2NC/1NO+2NC  
3NC+1NC/1NO  
3NC+2NC  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
Pg13.5  
G1/2  
M20  
3
D4GL/D4GL-SK10-LK@  
Contact configuration  
(door open/closed  
detection switch and lock  
monitor switch contacts)  
Head  
material  
Release  
key type  
Solenoid voltage/  
indicator  
Lock and release  
types  
Conduit size  
Model  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
G1/2  
M20  
D4GL-2AFA-A-SJ  
D4GL-4AFA-A-SJ  
D4GL-2BFA-A-SJ  
D4GL-4BFA-A-SJ  
D4GL-2CFA-A-SJ  
D4GL-4CFA-A-SJ  
D4GL-2DFA-A-SJ  
D4GL-4DFA-A-SJ  
D4GL-2EFA-A-SJ  
D4GL-4EFA-A-SJ  
D4GL-2FFA-A-SJ  
D4GL-4FFA-A-SJ  
D4GL-2GFA-A-SJ  
D4GL-4GFA-A-SJ  
D4GL-2HFA-A-SJ  
D4GL-4HFA-A-SJ  
D4GL-2AFG-A-SJ  
D4GL-4AFG-A-SJ  
D4GL-2BFG-A-SJ  
D4GL-4BFG-A-SJ  
D4GL-2CFG-A-SJ  
D4GL-4CFG-A-SJ  
D4GL-2DFG-A-SJ  
D4GL-4DFG-A-SJ  
D4GL-2EFG-A-SJ  
D4GL-4EFG-A-SJ  
D4GL-2FFG-A-SJ  
D4GL-4FFG-A-SJ  
D4GL-2GFG-A-SJ  
D4GL-4GFG-A-SJ  
D4GL-2HFG-A-SJ  
D4GL-4HFG-A-SJ  
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
1NC/1NO+1NC/1NO  
1NC/1NO+2NC  
2NC+1NC/1NO  
2NC+2NC  
Mechanical lock  
Solenoid release  
2NC/1NO+1NC/1NO  
2NC/1NO+2NC  
3NC+1NC/1NO  
3NC+2NC  
Solenoid: 24 VDC  
Orange/green LED:  
24 VDC  
Standard  
(metal)  
Plastic  
1NC/1NO+1NC/1NO  
1NC/1NO+2NC  
2NC+1NC/1NO  
2NC+2NC  
Solenoid lock  
Mechanical release  
2NC/1NO+1NC/1NO  
2NC/1NO+2NC  
3NC+1NC/1NO  
3NC+2NC  
* These models will receive Korean S-mark certification.  
Operation Keys  
Type  
Model  
Horizontal mounting  
D4DS-K1  
Vertical mounting  
D4DS-K2  
Adjustable mounting  
(Horizontal)  
D4DS-K3  
D4DS-K5  
Adjustable mounting  
(Horizontal/Vertical)  
4
D4GL/D4GL-SK10-LK@  
Slide keys  
Appearance  
Specifications  
Contents  
Model  
Applicable Door Switch  
Slide Key: 1 (not yet mounted)  
D4GL mounting plate: 1  
Door Switch special mounting screws: 4  
Weight: Approx. 0.6 kg D4DS-K1 (operation key): 1  
Mechanical durability: D4DS-K1 special mounting screws: 2  
20,000 operations min. Lockout keys: 2  
Lockout key strap: 1  
D4GL-SK10-LK  
D4GL  
Caution labels (stickers): 2 sheets (English  
and Japanese)  
Weight:Approx.0.1kg  
Inner Lever:1  
D4SL-SK10H*  
-
Slide Key: 1 (not yet mounted)  
D4GL mounting plate: 1  
Door Switch special mounting screws: 4  
D4DS-K1 (operation key): 1  
Mechanical durability: D4DS-K1 special mounting screws: 2  
20,000 operations min. Lockout keys: 2  
Lockout key strap: 1  
Weight:Approx.0.7kg  
D4GL-SK10-LKH  
D4GL  
Caution labels (stickers): 2 sheets (English  
and Japanese)  
Note: 1. The Door Switch is not included. Select the Door Switch depending on the necessary number of contacts and the conduit size.  
The contents are provided as a total set, individual contents cannot be ordered separately.  
2. Perform risk assessment for the equipment in question, configure relay units and other safety circuits, and use properly.  
* The inner lever for D4GL-SK10-LK/D4SL-NSK10-LK that can not be used for other products and applications.  
D4GL-SK10-LK  
+ =  
D4GL-SK10-LK  
D4GL  
D4GL-SK10-LKH  
+ =  
D4GL-SK10-LKH  
D4GL  
5
D4GL/D4GL-SK10-LK@  
Features  
The lockout key prevents workers from becoming trapped without using a padlock.  
Note: Using two-color LEDs enables confirming whether the door is open or closed and locked or unlocked.  
Example: D4GL-2DFA-A with mechanical lock and solenoid release  
Locked (power not  
supplied to solenoid)  
The slide handle is closed.  
Close door.  
The handle-shaped fixture makes  
it easy to use the Door Switch.  
Attach the supplied  
caution labels for display.  
Locked (power not  
supplied to solenoid)  
The slide handle is closed.  
Close door.  
Door Opening to  
the Left.  
Left door  
Lockout Key  
Do not turn the key as in the figure above if the  
slide handle is closed.  
The slide handle can be pulled.  
Open door. The slide handle is open.  
The slide handle is open.  
Open door.  
Open door.  
The slide handle is open.  
The slide handle  
does not move.  
The slide handle is secured at the position  
shown in the figure.  
A worker holding the lockout key will not be  
trapped locked inside the hazardous area by  
another person.  
When the slide handle is open, the  
lockout key can be pulled regardless  
of whether power is being supplied  
to the solenoid or not.  
If the lockout key is not mounted, the  
slide handle will not move and the  
door will not close.  
6
D4GL/D4GL-SK10-LK@  
Specifications  
Standards and EC Directives  
Conforms to the following EC Directives:  
Characteristics  
Degree of protection *1  
IP67 (EN60947-5-1)  
Machinery Directive  
Low Voltage Directive  
EN1088  
EN60204-1  
GS-ET-19  
Mechanical  
1,000,000 operations min.  
500,000 operations min. (4 mA  
resistive load at 24 VDC)  
150,000 operations min. (1 A  
resistive load at 125 VAC, 2  
circuits/4 mA resistive load at  
24 VDC, 2 circuits) *3  
Durability *2  
Electrical  
Certified Standards  
Standard type  
Operating speed  
0.05 to 0.5 m/s  
Certification body  
Standard  
File No.  
Operating frequency  
Direct opening force *4  
Direct opening travel *4  
Holding force *5  
30 operations/minute max.  
60 N min. (EN60947-5-1)  
10 mm min. (EN60947-5-1)  
1,000 N min.  
EN60947-5-1  
(certified direct opening)  
Consult your OMRON  
representative for details.  
TÜV SÜD  
UL *1  
CQC (CCC)  
UL508, CSA C22.2 No.14  
GB14048.5  
E76675  
2003010305064264  
Contact resistance  
100 mΩ max.  
4 mA resistive load at 24 VDC (N-  
level reference value)  
Consult your OMRON  
representative for details.  
KOSHA *2  
EN 60947-5-1  
Minimum applicable load *6  
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.  
*2. Only certain models have been certified.  
Rated insulation voltage (Ui) 300 V (EN60947-5-1)  
Rated frequency 50/60 Hz  
Protection against electric shock Class II (double insulation)  
Metallic release key type  
Pollution degree (operating  
Certification body  
Standard  
File No.  
3 (EN60947-5-1)  
environment)  
EN60947-5-1  
(certified direct opening)  
Consult your OMRON  
representative for details.  
TÜV SÜD  
Between  
terminals of  
same polarity  
2.5 kV  
4 kV  
Consult your OMRON  
representative for details.  
KOSHA  
EN 60947-5-1  
Between  
terminals of  
different polarity  
Certified Standard Ratings  
TÜV (EN60947-5-1), CCC (GB14048.5)  
Impulse  
withstand  
voltage  
(EN60947-5-  
1)  
Between  
solenoid and  
non-current  
carrying  
0.8 kV  
4 kV  
Utilization  
category  
AC-15  
DC-13  
Item  
metallic parts  
Rated operating current (Ie)  
Rated operating voltage (Ue)  
0.75 A  
240 V  
0.27 A  
250 V  
Between other  
terminals and  
non-current  
carrying  
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a  
short-circuit protection device.  
metallic parts  
Insulation resistance  
Contact gap  
100 MΩ min. (at 500 VDC)  
2 × 2 mm min.  
UL/CSA (UL508, CSA C22.2 No. 14)  
C300  
Vibration  
10 to 55 Hz, 0.75 mm single  
amplitude  
1,000 m/s2 min.  
300 m/s2 min.  
Current (A)  
Make Break  
15 1.5  
7.5 0.75  
Volt-amperes (VA)  
Rated  
Malfunction  
Carry current  
resistance  
voltage  
Make  
Break  
Destruction  
Malfunction  
Shock  
resistance  
120 VAC  
240 VAC  
2.5 A  
1,800  
180  
Conditional short-circuit  
current  
100 A (EN60947-5-1)  
2.5 A (EN60947-5-1)  
Q300  
Conventional free air thermal  
current (Ith)  
Current (A)  
Volt-amperes (VA)  
Rated  
voltage  
Carry current  
Make  
0.55  
0.27  
Break  
0.55  
Make  
Break  
Ambient operations temperature 10 to 55°C (with no icing)  
Ambient operations humidity 95% max.  
125 VAC  
250 VAC  
2.5 A  
69  
69  
0.27  
Weight  
Approx. 400 g (D4GL-1AFA-A)  
Note: 1. The above values are initial values.  
2. The Switch contacts can be used with either standard loads  
or microloads. Once the contacts have been used to switch a  
load, however, they cannot be used to switch smaller loads.  
The contact surfaces will become rough once they have been  
used and contact reliability for smaller loads may be reduced.  
*1. The degree of protection is tested using the method specified by the  
standard (EN60947-5-1). Confirm that sealing properties are sufficient  
for the operating conditions and environment beforehand. Although the  
switch box is protected from dust or water penetration, do not use the  
D4GL in places where foreign material may enter through the key hole  
on the head, otherwise Switch damage or malfunctioning may occur.  
*2. The durability is for an ambient temperature of 5 to 35°C and an  
ambient humidity of 40% to 70%. For more details, consult your  
OMRON representative.  
*3. Do not pass the 1 A, 125 VAC load through more than 2 circuits.  
*4. These figures are minimum requirements for safe operation.  
*5. This figure is based on the GS-ET-19 evaluation method.  
*6. This value will vary with the switching frequency, environment,  
and reliability level. Confirm that correct operation is possible with  
the actual load beforehand.  
Solenoid Coil Characteristics  
Item  
Type  
24 VDC  
Rated operating voltage  
(100% ED)  
24 VDC 10%  
Current consumption  
Insulation  
Approx. 200 mA  
Class B (130°C max.)  
Indicator Characteristics  
Item  
Type  
LED  
Rated voltage  
Current leakage  
Color (LED)  
24 VDC  
Approx. 3 mA  
Orange/Green  
7
D4GL/D4GL-SK10-LK@  
Connections  
Connection Example for D4GL-1HFA-A  
Internal Circuit Diagram  
Indicator  
51  
Solenoid  
24V DC  
12  
41  
42  
52  
22  
31  
D4GL-@@@@-@@  
Safety  
circuit  
11  
21  
E1 (+)  
D
Auxiliary  
circuit  
LED (Green) (+)  
D
Auxiliary  
circuit  
LED (Orange) (+)  
Auxiliary  
circuit  
E2 ()  
LED  
LED  
32  
E1  
(Green) (Orange)  
O2  
(Black)  
O1 (Green)  
LED  
(Green)  
E2  
5 to 24V DC  
Solenoid  
CRD  
CRD  
ZD  
ZD  
O3 (Orange)  
LED  
(Orange)  
Direct opening contacts used as safety-circuit input are indicated  
with the mark.  
COM ()  
Terminals 11 and 12 and terminals 21 and 22 are direct opening  
contacts.  
Connect the indicators in parallel to the auxiliary circuits or  
terminals E1 and E2.  
D4GL-@@@@-@@-SJ  
D
LED (Green) (+)  
Although the 3 lines are connected at the time of delivery, rewire  
them as necessary for the application.  
LED  
(Green)  
<D4GL-@@@@-@@>  
5 to 24V DC  
Connected  
CRD  
ZD  
Terminal  
number  
Lead wire  
color  
Indicator  
terminal  
number *  
Green indicator (+)  
Orange indicator (+)  
Common (-)  
01  
03  
02  
Green  
Orange  
Black  
31  
E1  
E2  
LED (Green) ()  
LED (Orange) (+)  
D
<D4GL-@@@@-@@-SJ>  
LED  
(Orange)  
Connected  
terminal  
number *  
Terminal  
number  
Lead wire  
color  
Indicator  
Green indicator (+)  
Green indicator (-)  
Orange indicator (+)  
Orange indicator (-)  
01  
04  
03  
05  
Green  
White  
31  
5 to 24V DC  
CRD  
ZD  
Orange  
Black  
E1  
E2  
LED (Orange) ()  
* The terminal number of green indicator will be different according to  
the contact configuration.  
Circuit Connection Example  
D4GL-@@@@-@@  
Terminals 12 and 41 are connected internally and so connect  
terminals 11 and 42 for safety-circuit input. (BIA GS-ET-19)  
Connect terminals 21 and 22 and terminals 51 and 52 in series  
when using as safety-circuit input (redundancy circuit for terminals  
11 and 12 and terminals 41 and 42 above). Connect the terminals  
individually when using as auxiliary-circuit input (e.g., terminals 21  
and 22 for safety-door open/closed monitoring and terminals 51  
and 52 for monitoring the lock status).  
2
2” : A, B, E, or F =33  
2” : C or D  
2” : G or H  
=21  
=31  
If an indicator is connected in parallel to a direct opening contact,  
when the indicator breaks, a short-circuit current will be generated,  
possibly resulting in an installation malfunction.  
Do not switch circuits for two or more standard loads at the same  
time. Doing so may adversely affect insulation performance.  
DC solenoids have polarity. Confirm terminal polarity before wiring.  
In the following connection example, terminals 21 and 22 and  
terminals 51 and 52 are used as auxiliary-circuit input.  
In this case,the green indicator lights when the door is closed and  
the orange indicator lights when the solenoid turns ON.  
8
D4GL/D4GL-SK10-LK@  
Operation Method  
Operation Principles  
Plunger return spring  
Lock spring  
LOCK  
UNLOCK  
Linking arm  
The lock plate  
and monitor  
switch are linked.  
Mechanical  
lock  
models  
Return spring  
OFF  
OFF  
ON  
When the door is closed, it is locked by the The solenoid is released only when the  
lock spring. The door will stay locked even lock is turned ON.  
if there is a power interruption.  
Plunger return spring  
Lock return spring  
LOCK  
UNLOCK  
Linking arm  
The lock plate  
and monitor  
switch are linked.  
Return spring  
Solenoid  
lock  
models  
ON  
OFF  
OFF  
If the solenoid is OFF, the door will not be The door is locked only when the solenoid  
locked when it is closed. This means that is turned ON. This means that the door will  
the door can be opened and closed easily be unlocked if there is a power interruption  
when replacing workpieces or parts.  
and so this model cannot be used in  
systems that would maintain a hazardous  
state (e.g., systems requiring toxic gases,  
high temperatures, or gears that would  
continue to turn due to inertia).  
Structure and Nomenclature  
Structure  
Operation key hole  
Indicator (green)  
Indicator (orange)  
Terminal 42  
Release key  
Terminal 21  
Terminal 11  
Terminal 22  
Terminal 31/33  
Terminal 51/53  
Terminal 32/34  
Conduit opening  
Terminal E2 ()  
Terminal 52/54  
Conduit opening  
Terminal E1 (+)  
Cover  
Note: Terminal numbers vary with the model. Confirm terminal numbers by referring to the cover on the back of the Switch.  
9
D4GL/D4GL-SK10-LK@  
Contact Form  
Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41 are connected internally (as per BIA GS-ET-19).  
Contact form  
Contact  
(door open/closed  
detection and lock  
monitor)  
Door open/  
Model  
Operating pattern  
Remarks  
closed  
Lock monitor  
detection  
Lock position  
Only NC contact 11-12  
has a certified direct  
opening mechanism.  
Door open/  
closed detection  
Zb  
Lock monitor  
11-42  
33-34  
53-54  
Zb  
42  
ON  
D4GL-@AF@-@ 1NC/1NO + 1NC/1NO  
11  
12 41  
The terminals 11-42,  
33-34, and 53-54 can  
be used as unlike poles.  
Stroke  
Operation Key insertion  
completion position  
33  
34 53  
54  
Extraction completion  
position  
Lock position  
Only NC contact 11-12,  
has a certified direct  
opening mechanism.  
Door open/  
closed detection  
Zb  
Lock monitor  
Zb  
11-42  
33-34  
51-52  
ON  
D4GL-@BF@-@  
D4GL-@CF@-@  
1NC/1NO + 2NC  
2NC + 1NC/1NO  
11  
12 41  
42  
The terminals 11-42,  
33-34, and 51-52 can  
be used as unlike poles.  
Stroke  
Operation Key insertion  
completion position  
33  
34 51  
52  
Extraction completion  
position  
Lock position  
Only NC contacts 11-12  
and 21-22 have a  
certified direct opening  
mechanism.  
Door open/  
Lock monitor  
Zb  
11-42  
21-22  
53-54  
closed detection  
Zb  
11  
ON  
12 41  
42  
The terminals 11-42,  
21-22, and 53-54 can  
be used as unlike poles.  
Stroke  
Operation Key insertion  
completion position  
21  
22 53  
54  
Extraction completion  
position  
Lock position  
Only NC contacts 11-12  
and 21-22 have a  
certified direct opening  
mechanism.  
Door open/  
closed detection  
Zb  
Lock monitor  
Zb  
11-42  
21-22  
51-52  
ON  
D4GL-@DF@-@  
2NC + 2NC  
11  
12 41  
42  
The terminals 11-42,  
21-22, and 51-52 can  
be used as unlike poles.  
Stroke  
Operation Key insertion  
completion position  
21  
22 51  
52  
Extraction completion  
position  
Lock position  
Only NC contacts 11-12  
and 21-22 have a  
certified direct opening  
mechanism.  
Door open/  
closed detection  
Zb  
Lock monitor  
Zb  
11-42  
21-22  
33-34  
53-54  
ON  
11  
12 41  
42  
D4GL-@EF@-@ 2NC/1NO + 1NC/1NO  
The terminals 11-42,  
21-22, 33-34, and 53-54  
can be used as unlike  
poles.  
21  
33  
22 53  
34  
54  
Stroke  
Operation Key insertion  
completion position  
Extraction completion  
position  
Lock position  
Only NC contacts 11-12  
and 21-22 have a  
certified direct opening  
mechanism.  
Door open/  
closed detection  
Zb  
Lock monitor  
Zb  
11-42  
21-22  
33-34  
51-52  
ON  
11  
12 41  
42  
D4GL-@FF@-@  
D4GL-@GF@-@  
D4GL-@HF@-@  
2NC/1NO + 2NC  
3NC + 1NC/1NO  
3NC + 2NC  
The terminals 11-42,  
21-22, 33-34, and 51-52  
can be used as unlike  
poles.  
21  
33  
22 51  
34  
52  
Stroke  
Operation Key insertion  
completion position  
Extraction completion  
position  
Lock position  
Only NC contacts 11-12,  
21-22, and 31-32 have a  
certified direct opening  
mechanism.  
Door open/  
closed detection  
Zb  
Lock monitor  
Zb  
11-42  
21-22  
31-32  
53-54  
ON  
11  
12 41  
42  
The terminals 11-42,  
21-22, 31-32, and 53-54  
can be used as unlike  
poles.  
21  
31  
22 53  
32  
54  
Stroke  
Operation Key insertion  
completion position  
Extraction completion  
position  
Lock position  
Only NC contacts 11-12,  
21-22, and 31-32 have a  
certified direct opening  
mechanism.  
Door open/  
closed detection  
Zb  
Lock monitor  
Zb  
11-42  
21-22  
31-32  
51-52  
ON  
11  
12 41  
42  
The terminals 11-42,  
21-22, 31-32, and 51-52  
can be used as unlike  
poles.  
21  
31  
22 51  
32  
52  
Stroke  
Operation Key insertion  
completion position  
Extraction completion  
position  
10  
D4GL/D4GL-SK10-LK@  
Dimensions  
(Unit: mm)  
Dimensions and Operating Characteristics  
Switches  
D4GL-@@@@-A4  
D4GL-@@@@-A  
Four, head mounting screws  
Head cap  
Four, head mounting screws  
Head cap  
Pre-travel  
distance  
Pre-travel  
distance  
Operation Key  
47.8  
40  
38  
Operation Key  
47  
40  
38  
34.4  
15.3  
34.4  
15.3  
23.5  
23.5  
Four, 5.2-dia.  
holes  
Four, 5.2-dia.  
holes  
Four, 9.2-dia. spot  
facings (depth: 10)  
Four, 9.2-dia. spot  
facings (depth: 10)  
Four, LED  
indicators  
Four, LED  
indicators  
Release key  
Release key  
Cover mounting  
screw  
Cover mounting  
screw  
Two, cap screws  
Two, cap screws  
(21.5)  
23.5  
30 0.2  
43  
(21.5)  
23.5  
30 0.2  
43  
(3)  
(3)  
(3)  
(3)  
Conduit cap  
Conduit cap  
Operating  
characteristics  
Model  
Operating  
characteristics  
Model  
D4GL-@@@@-A4  
D4GL-@@@@-A  
Key insertion force  
Key extraction force  
15 N max.  
40 N max.  
Key insertion force  
Key extraction force  
15 N max.  
40 N max.  
Pre-travel distance  
10 mm max.  
Pre-travel distance  
10 mm max.  
Movement before  
being locked  
Movement before  
being locked  
4 mm min.  
4 mm min.  
Operation Keys  
D4DS-K3  
D4DS-K1  
17.5 28  
13  
14 28  
Angle adjustment bolt  
9 dia.  
4
8 dia.  
4.5 dia.  
4.3  
7
7
30 15  
13  
13  
30 40 56  
20°  
Four, 2.15R  
Black  
2
2
6.3  
15  
10.5  
Mounting Holes  
(Enlargement)  
17  
13.5  
4.5  
D4DS-K2  
D4DS-K5  
20.9  
4
28  
24.6  
6
7
7
9
28  
22.5  
30  
13  
15  
8
15°  
30  
55  
41  
43  
2
4.3  
13  
18°  
41  
43  
Four, 2.15R  
Black  
6.5  
(7)  
8
1
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
11  
D4GL/D4GL-SK10-LK@  
Slide keys  
D4GL-SK10-LK  
(Open door.)  
(Close door.)  
10  
(98)  
40×40  
40×40  
12.5  
(40)  
Lockout key  
(8)  
(29)  
(230)  
(84)  
(314)  
(28)  
(112)  
(35)  
(147)  
107  
(35)  
(71.8)  
+10  
-5  
15  
(20)  
19.1  
11.5  
17  
Shot bolt  
SLIDE  
LOCK  
(56.5)  
SLIDE  
LOCK  
SLIDE  
FREE  
SLIDE  
FREE  
50 (64) (90.4)  
Guide  
(76.2)  
Four, M6 mounting holes  
Slide base  
(32.5)  
D4DS-K1  
Operation Key  
84.1  
(350)  
UN  
UN  
–LOCK  
–LOCK  
LOCK  
LOCK  
4
30  
4-M5  
Cross-sectional  
view A-A  
(22.7)  
17  
Guard Lock Safety-door  
Switch D4GL  
A
A
11.5  
12.5  
8
Two, M6  
mounting holes  
Switch base  
D4GL-SK10-LKH  
(Open door.)  
(Close door.)  
10  
Aluminum frame  
40×40  
12.5  
Lockout key  
(323)  
(147)  
(40)  
(121)  
(29)  
(239)  
84  
(71.8)  
(35)  
107  
19.1  
37  
(20)  
11.5  
17  
(115)  
(56.5)  
SLIDE  
LOCK  
SLIDE  
LOCK  
(78)  
SLIDE  
FREE  
SLIDE  
FREE  
50 (64) (90.4)  
Guide  
(76.2)  
Ø12  
Ø40  
Inner Lever  
(32.5)  
Slide base  
D4DS-K1  
(35)  
Operation Key  
Four, M6 mounting holes  
Shot bolt  
(350)  
84.1  
UN  
–LOCK  
UN  
4
–LOCK  
LOCK  
LOCK  
Cross-sectional  
view A-A  
30  
4-M5  
Guard Lock Safety-door  
Switch D4GL  
+10  
-5  
15  
Between slyde key unit  
(22.7)  
17  
A
A
11.5  
12.5  
8
Two, M6  
Switch base  
mounting holes  
12  
D4GL/D4GL-SK10-LK@  
With Operation Key Inserted  
D4GL + D4DS-K1  
D4GL + D4DS-K1  
(with Front-inserted Operation Key)  
(with Top-inserted Operation Key)  
Horizontal  
insertion radius:  
R 200  
(38)  
51.5 min. 54 max.  
Key insertion position  
Center  
tolerance of  
key hole:  
1
Vertical  
insertion radius:  
R 200  
Horizontal  
insertion radius:  
R 200  
Vertical  
insertion radius:  
R 200  
Center  
tolerance of  
Center  
tolerance of  
key hole:  
Center  
tolerance of  
key hole: 1  
(15.2)  
key hole:  
1
(15)  
1
52.5 min. 55.0 max.  
Key insertion position  
52.5 min. 55.0 max.  
Key insertion position  
D4GL + D4DS-K2  
D4GL + D4DS-K2  
(with Front-inserted Operation Key)  
(with Top-inserted Operation Key)  
Horizontal  
insertion radius:  
R 200  
(38)  
47.5 min. 50 max.  
Key insertion position  
Center  
tolerance of  
key hole:  
1
Vertical  
insertion radius:  
R 200  
Vertical  
Horizontal  
insertion radius:  
200  
insertion radius:  
200  
R
R
Center  
tolerance of  
Center  
tolerance of  
key hole:  
Center  
tolerance of  
key hole: 1  
(15.2)  
key hole:  
1
(6)  
(15)  
1
48.5 min. 51.0 max.  
Key insertion position  
48.5 min. 51.0 max.  
Key insertion position  
13  
D4GL/D4GL-SK10-LK@  
D4GL + D4DS-K3  
(with Front-inserted Operation Key)  
D4GL + D4DS-K3  
(with Top-inserted Operation Key)  
Horizontal  
insertion radius:  
R 50  
(38)  
52.5 min. 55 max.  
Key insertion position  
Center  
tolerance of  
key hole:  
1
Vertical  
insertion radius:  
R 200  
Vertical  
insertion radius:  
R 200  
Horizontal  
insertion radius:  
R 50  
Center  
tolerance of  
Center  
tolerance of  
key hole:  
Center  
tolerance of  
key hole:  
(15.2)  
key hole:  
1
(40)  
1
1
53.5 min. 56.0 max.  
Key insertion position  
53.5 min. 56.0 max.  
Key insertion position  
D4GL + D4DS-K5  
D4GL + D4DS-K5  
(with Front-inserted Operation Key)  
(with Top-inserted Operation Key)  
Horizontal  
insertion radius:  
R 50  
(38)  
59.5 min. 62 max.  
Key insertion position  
Center  
tolerance of  
key hole:  
1
Vertical  
insertion radius:  
R 50  
Horizontal  
insertion radius:  
R 50  
Horizontal  
insertion radius:  
R 50  
43 0.1  
Center  
tolerance of  
Center  
tolerance of  
key hole:  
(15.2)  
41 0.1  
Center  
1
key hole:  
1
tolerance of  
key hole:  
1
60.4 min. 62.9 max.  
Key insertion position  
60.4 min. 62.9 max.  
Key insertion position  
14  
D4GL/D4GL-SK10-LK@  
Application Examples  
PL/safety category  
Model  
Stop category  
Reset  
Guard Lock Safety-door Switch D4GL-@AFA-@ (Mechanical Lock Type)  
Safety Relay Unit G9SA-321-T@ (24 VAC/VDC)  
PLd/3 equivalent  
1
Manual  
Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions.  
Application Overview  
The stop signal is sent to the motor controller.  
The power supply to the motor M is turned OFF after OFF-delay time.  
The lock release signal enables the guard to be opened.  
The S1 and S2 monitor the guard, and the power supply to the motor M is kept OFF while the guard is opened.  
The power supply to the motor M is turned ON again when the reset switch S3 is pressed while the guard is closed and locked.  
Lock release signal  
KM1  
KM2  
S2  
S4  
42  
54  
S1:  
Safety Limit Switch  
with direct opening mechanism  
(D4B-N, D4N, D4F)  
Guard Lock Safety-door Switch  
Reset switch  
Lock release switch  
41  
12  
53  
34  
33  
S2:  
S3:  
S4:  
11  
KM1 and KM2: Magnetic Contactor  
PLC  
PLC  
M:  
3-phase motor  
Guard  
11  
12  
S1  
Feedback loop  
OPEN  
KM1  
KM2  
S3  
Stop signal  
T31  
T32  
33 43 53  
61  
A1 A2 T11  
T12  
K1  
13 23  
1
3
4
TH  
SA  
K3  
K4  
a
K2  
K3  
K4  
1
2
3
4
a
b
Off delay  
timer  
Control  
circuit  
JP  
5
6
2
5
K1  
K2  
K1  
b
K2  
6
54 62  
PE T21  
T23 T22  
A
B
14 24 34 44  
KM1 KM2  
Guard opens  
Timing Chart  
Limit switch S1  
Operation  
instruction  
Guard Lock  
Safety-door  
Switch S2  
Motor controller  
Lock release  
signal  
KM1  
KM2  
S4  
Guard can be opened  
Stop signal  
Reset switch  
S3  
K1 and K2  
(NC)  
M
K1 and K2  
(NO)  
K3 and K4  
(NC)  
K3 and K4  
(NO)  
KM1 and KM2  
(NC)  
KM1 and KM2  
(NO)  
Operation  
instruction  
Motor rotation  
OFF-delay time  
15  
D4GL/D4GL-SK10-LK@  
PL/safety category  
Model  
Stop category  
Reset  
Guard Lock Safety-door Switch D4GL-@AFG-@ (Solenoid Lock Type)  
Safety Relay Unit G9SA-301 (24 VAC/VDC)  
PLe/4 equivalent  
0
Auto  
Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions.  
Application Overview  
The power supply to the motor M is turned OFF immediately by the stop signal.  
The guard can be opened by turning OFF the lock signal.  
The S1 and S2 monitor the guard, and the power supply to the motor M is kept OFF while the guard is opened.  
The power supply to the motor M is turned ON again when the guard is closed and locked.  
Lock signal  
S2  
42  
41  
S1:  
S2:  
Safety Limit Switch  
with direct opening mechanism  
(D4B-N, D4N, D4F)  
54  
53  
Guard Lock Safety-door Switch  
12  
11  
34  
33  
KM1 and KM2: Magnetic Contactor  
M:  
3-phase motor  
PLC  
PLC  
S1  
Guard  
12  
11  
Feedback loop  
KM1  
OPEN  
KM2  
Operation signal  
A1 A2 T11  
TH  
T12  
T31  
T32  
13 23 33 41  
3
4
1
K1  
K2  
a
K1  
K2  
1
2
3
4
5
SA  
Control  
Circuit  
a
b
2
5
JP  
K1  
6
b
K2  
6
PE T21  
T23 T22  
A
B
14 24 34 42  
KM1 KM2  
Stop  
instruction  
Motor controller  
KM1  
Guard opens  
Timing Chart  
KM2  
Limit switch S1  
Guard Lock Safety-door Switch S2  
Operation signal  
M
Lock signal  
K1 and K2  
(NC)  
Note: The lock can be released at any time. Therefore, do not  
use a model with a solenoid lock in applications where  
the operator may be exposed to danger when the guard  
opens. Use a model with a mechanical lock.  
K1 and K2  
(NO)  
KM1 and KM2  
(NC)  
KM1 and KM2  
(NO)  
16  
D4GL/D4GL-SK10-LK@  
Safety Precautions  
Be sure to read the precautions for All Safety Door Switches in the website at:http://www.ia.omron.com/.  
Indication and Meaning for Safe Use  
Wiring  
Do not switch circuits for two or more standard loads (125 VAC,  
1 A). Doing so may adversely affect insulation performance.  
Always attach the cover after completing wiring and before using  
the Switch. Do not supply power when the cover is not attached.  
Electric shock may occur if the Switch is used without the cover  
attached.  
Indicates an imminently hazardous  
situation which, if not avoided, is likely to  
result in serious injury or may result in  
death. Additionally there may be severe  
property damage.  
DANGER  
Indicates a potentially hazardous situation  
which, if not avoided, may result in minor  
Installation  
CAUTION  
Make sure the Switch is mounted securely to prevent it from falling  
off. Otherwise injury may result.  
or moderate injury or in property damage.  
Do not use a Switch as a stopper.  
Precautions  
for Safe Use  
Supplementary comments on what to do  
or avoid doing, to use the product safely.  
Be sure to install a stopper as shown in the following illustration  
when mounting the Switch and adjust the stopper so that the  
Operation Key is within the setting zone. (Setting zone: 0.5 to 3.0  
mm)  
Supplementary comments on what to do  
or avoid doing, to prevent failure to  
operate, or undesirable effect on product  
performance.  
Precautions  
for Correct  
Use  
Set zone  
(0.5 to 3 mm)  
Stopper  
DANGER  
Injury may occasionally occur. Always check to make  
sure that the safety functions operate correctly before  
using the machine. The safety functions may not operate  
correctly because of wiring mistakes, setting mistakes,  
or Switch malfunction, causing some machines to  
continue operating in situations where they should be  
stopped.  
Operation Key  
Do not subject the Switch to a shock that exceeds the Switch's  
shock resistance of 1,000 m/s2.  
Injury may occasionally occur. If the machine is used  
with the release key in the UNLOCK position, the  
electromagnetic lock may not operate, causing some  
machines to continue operating in situations where they  
should be stopped. Be sure to put the release key in the  
LOCK position before using the machine. Also, check  
the condition of the lock and safety circuits.  
Precautions for Correct Use  
The Switch contacts can be used with either standard loads or  
microloads. Once the contacts have been used to switch a load,  
however, they cannot be used to switch smaller loads. The contact  
surfaces will become rough once they have been used and contact  
reliability for smaller loads may be reduced.  
Injury may occasionally occur. Always ensure that the  
release key is set to "UNLOCK" or that the Operation  
Key is inserted before changing the direction of the head.  
Not doing so may damage the Switch, causing some  
machines to continue operating in situations where they  
should be stopped. Refer to “Release Key” on page 17.  
Release Key  
The release key is used to unlock the Switch in case of emergency  
or if the power supply to the Switch stops.  
If the release key setting is changed from LOCK to UNLOCK, the  
lock will be released and the safety door can be opened  
(mechanical lock models only).  
After setting the release key to UNLOCK to, for example, perform  
maintenance, be sure to return it to LOCK setting before resuming  
operation.  
Do not use the release key to start or stop machines.  
The auxiliary lock must be released only by authorized personnel.  
Do not impose a force exceeding 0.5 N·m on the release key  
screws. The release key may be damaged and may not operate  
properly.  
The release key is set in the unlock position at the factory for the  
D4GL-@@@A and to the lock position for the D4GL-@@@G.  
To prevent the release key from being used by unauthorized  
personnel, set it to LOCK and seal it with sealing wax.  
Injury may occasionally occur. When the  
electromagnetic lock function or Switch function is  
damaged, some machines may continue operating in  
situations where they should be stopped. Do not use the  
electromagnetic lock function of the Switch in place of a  
door lock. Always provide a lock separate from the  
Switch, attach a warning seal to prevent people from  
using excessive force to open the door when it is locked,  
or provide an indicator lamp to show the locked/unlocked  
status of the door.  
!CAUTION  
Electric shock may occasionally occur.  
Do not use metal connectors or metal conduits.  
Figure 1  
Precautions for Safe Use  
Installation Environment  
Do not use the Switch submersed in oil or water or in locations  
continuously subject to splashes of oil or water. Doing so may  
result in oil or water entering the Switch. (The IP67 degree of  
protection of the Switch specifies the amount of water penetration  
after the Switch is submerged in water for a certain period of time.)  
D4GL-@@@A-@  
D4GL-@@@A-@4  
D4GL-@@@G-@  
D4GL-@@@G-@4  
17  
D4GL/D4GL-SK10-LK@  
Head Direction  
Hinged Door  
Remove the four screws of the head to enable changing the  
mounting direction of the head. The head can be mounted in four  
directions. Ensure that no foreign material enters the interior of the  
Switch. Also, insert the head until the insertion line engraved on the  
head is hidden by the reference line on the Switch, as shown in the  
following diagram.  
Do not insert or remove the Operation Key with the Switch head  
removed. Doing so may make it impossible to insert the Operation  
Key.  
If the Switch is mounted too close to the hinge, the force imposed on  
the lock will be much larger than for locations far from the hinge and  
the lock may be damaged. Mount the Switch close to the handle.  
Solenoid Lock Models  
The solenoid lock locks the door only when power is supplied to the  
solenoid. Therefore, the door will be unlocked if the power supply to  
the solenoid stops. Therefore, do not use solenoid lock models for  
machines that may be operating and dangerous even after the  
machine stops operating.  
Insertion line  
Mounting  
Appropriate Tightening Torque  
Reference line  
Be sure to tighten each screw of the Switch properly. Loose screws  
may result in malfunction.  
Terminal screw  
0.4 to 0.5 N·m  
0.5 to 0.7 N·m  
0.5 to 0.6 N·m  
Cover mounting screw  
Head mounting screw  
Securing the Door  
When the door is closed (with the Operation Key inserted), the  
Operation Key may exceed the set zone because of, for example, the  
door's own weight, machine vibration, or the door cushion rubber.  
Then, when an attempt is made to open the door, it may result in  
damage or malfunction. Also, it may not be possible to unlock the  
Switch if there is weight placed on the Operation Key. Do not rely on  
the Switch to substitute for a door locking device. Secure the door with  
a stopper so that the Operation Key remains within the set zone.  
Operation Key mounting  
screw  
2.4 to 2.8 N·m  
Switch mounting screw  
1.3 to 1.5 N·m  
1.8 to 2.1 N·m  
1.4 to 1.8 N·m  
1.3 to 1.7 N·m  
Connector  
Cap screw  
When loosening a screw with an electrical screwdriver or similar  
tool while pressing down on the screw head, do not continue  
turning the screw past the point where the threads disengage.  
Doing so may strip the end of the threads.  
Set zone  
(0.5 to 3 mm)  
Switch and Operation Key Mounting  
Operation key  
Mount the Switch and Operation Key securely to the applicable  
tightening torque with M5 screws for the Switch and M4 screws for  
the Operation Key. Always use spring washers. To ensure safety,  
use screws that cannot be easily removed or another means to  
prevent the Switch and Operation Key from easily being removed.  
Do not operate the Switch with anything other than the special  
OMRON Operation Key. Otherwise, the Switch may be damaged  
Solenoid  
The solenoid will heat when it carries current. Do not touch it.  
The solenoid has polarity. Confirm terminal polarity before wiring it.  
Wiring  
Circuit Connection Example for the D4GL-@H@@-A  
Direct opening contacts used as safety-circuit inputs are indicated  
with the  
have direct opening contacts.  
and the safety of the system may not be maintained.  
]
mark. Terminals 11 and 42, and terminals 21 and 22  
D4DS-K1/-K2  
Four, M5  
Two, M4  
Connect terminals 21 and 22 and terminals 51 and 52 in series  
when using as safety-circuit inputs (redundancy circuit for  
terminals 11 and 12 and terminals 41 and 42 below). Connect the  
terminals individually when using as auxiliary-circuit inputs (e.g.,  
terminals 21 and 22 for safety-door open/closed monitoring and  
terminals 51 and 52 for monitoring the lock status).  
In the following connection example, terminals 21 and 22 and  
terminals 51 and 52 are used as auxiliary-circuit inputs.  
Connect the indicators in parallel to the auxiliary circuits or  
terminals E1 and E2.  
0.1  
15  
Two, M4  
D4DS-K3  
0.2  
84  
0.1  
40  
Two, M4  
D4DS-K5  
0.1 or  
0.1  
43  
41  
0.1  
30  
Although the 3 lines are connected at the time of delivery, rewire  
them as necessary for the application.  
Ensure that the alignment offset between the Operation Key and  
the key hole does not exceed 1 mm. If the Operation Key is offset  
or at an angle, accelerated wear or damage to the Switch may  
result.  
Observe the specified insertion radius for the Operation Key and  
insert it in a direction perpendicular to the key hole.  
Do not impose excessive force on the Operation Key while the Key  
is inserted into the Switch or drop the Switch with the Operation  
Key inserted. Doing either of these may deform the Key or break  
the Switch.  
18  
D4GL/D4GL-SK10-LK@  
The following table shows the connection configuration required to  
make the green indicator light when the door is closed and the  
orange indicator light when the solenoid turns ON.  
Processing the Conduit Opening  
Connect a recommended connector to the opening of the conduit  
and tighten the connector to the proper torque. The case may be  
damaged if excessive tightening torque is applied.  
Make sure that the outer diameter of the cable connected to the  
connector is correct.  
Connected  
Terminal  
number  
Lead wire  
color  
Indicator  
terminal  
number  
Attach a conduit cap to the unused conduit opening when wiring  
and tighten it to a suitable torque. The conduit cap is provided with  
the Switch.  
Green indicator O1  
Orange indicator O3  
Green  
Orange  
Black  
31  
E1  
E2  
Common  
O2  
Recommended Connectors  
Use a connector with a screw section not exceeding 10 mm.  
Otherwise the screws will protrude into the case interior.  
The connectors given in the following table have connectors with  
screw sections not exceeding 10 mm.  
51  
12  
41  
42  
Safety  
11  
21  
circuit  
52  
22  
31  
Auxiliary  
circuit  
Use the following connectors to ensure conformance to IP67.  
Auxiliary  
circuit  
Applicable  
Auxiliary  
circuit  
32  
E1  
Size  
Manufacturer  
Model  
ST-PF1/2  
5380-1002  
OA-W1609  
OA-W1611  
cable  
O2  
(Black)  
diameter  
O1 (Green)  
LED  
(Green)  
E2  
LAPP  
6.0 to 12.0 mm  
Solenoid  
O3 (Orange)  
LED  
G1/2  
(Orange)  
7.0 to 9.0 mm  
9.0 to 11.0 mm  
OHM ELECTRIC  
CO.  
S-13.5  
5301-5030  
Wiring Precautions  
Do not wire the Switch while power is being supplied. Doing so may  
result in electric shock.  
Do not let particles, such as small pieces of lead wire, enter the  
switch body when wiring.  
Applicable lead wire size: AWG24 to AWG22 (0.2 to 0.3 mm2).  
Use lead wires of an appropriate length. Not doing so may result in  
excess length causing the cover to rise and not fit properly.  
Do not push crimp terminals into gaps in the case interior. Doing so  
may cause damage or deformation of the case.  
Use crimp terminals that will not interfere with other components  
inside the case.  
Pg13.5  
M20  
LAPP  
LAPP  
6.0 to 12.0 mm  
7.0 to 13.0 mm  
ST-M20 × 1.5  
5311-1020  
Use LAPP connectors together with Seal Packing (JPK-16,  
GP-13.5, or GPM20), and tighten to the applicable torque. Seal  
Packing is sold separately.  
LAPP is a German manufacturer.  
OHM Electric Co. is a Japanese manufacturer.  
Recommended Crimp Terminals  
Manufacturer  
Model  
FN0.5-3 (F Type)  
No. 5-3 (Straight Type)  
J.S.T. Mfg Co.  
The terminal block screws and contact numbers correspond as  
shown in the following diagram. The numbers are provided on the  
terminal cover. Confirm terminal numbers against the terminal  
block terminal symbols when wiring.  
19  
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron  
disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER  
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at  
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount  
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,  
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products  
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate  
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall  
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,  
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above  
warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself  
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,  
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product  
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence  
thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate  
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our  
practice to change part numbers when published ratings or features are changed, or when significant construction changes are  
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers  
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at  
any time to confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
2014.9  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2014 All Right Reserved.  

相关型号:

D4GL-4GDG-A4-NPT

SWITCH SAFETY 3PST 750MA 240V
OMRON

D4GL-4HFG-A

SWITCH SAFETY 3PST 750MA 240V
OMRON

D4GL-4HFG-A4-NPT

SWITCH SAFETY 3PST 750MA 240V
OMRON

D4GS-N2R-3

Snap Acting/Limit Switch
OMRON

D4H-SERIES

Interface IC
ETC

D4JB10

Bridge Rectifier
YANGJIE

D4JB100

Bridge Rectifier
YANGJIE

D4JL-1NFA-C6

Snap Acting/Limit Switch, 4PST, Momentary, Screw Terminal, Panel Mount,
OMRON

D4JL-1NFA-D5

Snap Acting/Limit Switch, 4PST, Momentary, Screw Terminal, Panel Mount,
OMRON

D4JL-1PFA-C5

Snap Acting/Limit Switch, 5PST, Momentary, Screw Terminal, Panel Mount,
OMRON

D4JL-2NFA-C7-01

Snap Acting/Limit Switch, 4PST, Momentary, Screw Terminal, Panel Mount
OMRON

D4JL-2NFA-D7-01

Snap Acting/Limit Switch, 4PST, Momentary, Screw Terminal, Panel Mount
OMRON