D4V-8111Z [OMRON]

Small Limit Switch;
D4V-8111Z
型号: D4V-8111Z
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Small Limit Switch

文件: 总8页 (文件大小:346K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Small Limit Switch  
D4V  
Compact Vertical Models Sized for Asian  
Standards  
• Compact new design approximately 1/3 the size of OMRON  
vertical Limit Switches.  
• Structure enables the terminal section to be fully opened for  
easy wiring.  
• RoHS complaint.  
• Degree of protection: IP65  
Model Number Structure  
Model Number Legend  
D4V-81@@Z  
1
1. Actuator type  
04: Roller lever  
12: Roller plunger  
22: Crossroller plunger  
66: Coil spring  
07: Rod lever  
08: Adjustable roller lever  
11: Push plunger  
69: Wire spring  
Ordering Information  
List of Models  
Actuator type  
Model  
Roller lever  
Rod lever  
D4V-8104Z  
D4V-8107Z  
Adjustable roller lever  
D4V-8108Z  
Push plunger  
Roller plunger  
D4V-8111Z  
D4V-8112Z  
Crossroller plunger  
Coil spring  
D4V-8122Z  
D4V-8166Z  
Wire spring  
D4V-8169Z  
Note: Metallic roller levers and metallic variable roller levers can also be manufactured.  
Small Limit Switch D4V  
1
Specifications  
Certified Standards  
Characteristics  
Certification body  
Standard  
File No.  
Degree of protection  
IP65  
CCC  
GB14048.5  
Consult your OMRON  
representative for  
details.  
Durability  
(See note 3.)  
Mechanical 10,000,000 operations min.  
UL (See note.)  
UL508,  
CSA C22.2 No. 14  
Electrical  
300,000 operations min.  
(5 A at 250 VAC, resistive load)  
TÜV  
IEC60947-5-1  
Operating speed  
5 mm to 0.5 m/s  
Operating  
frequency  
Mechanical 120 operations/min  
Note: Certification equivalent to CSA C22.2 No. 14 has been  
Electrical  
30 operations/min  
obtained from UL.  
Insulation resistance  
Contact resistance  
100 Mmin. (at 500 VDC)  
25 mmax. (initial value)  
1,000 VAC, 50/60 Hz for 1 min  
Ratings  
Dielectric  
strength  
Between  
terminalsof  
the same  
polarity  
Rated  
voltage  
(V)  
Non-inductive load (A)  
Inductive load (A)  
Resistive load Lamp load  
Inductive load Motor load  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
Between  
current-  
1,500 VAC, 50/60 Hz for 1 min  
125 VAC  
250 VAC  
5
5
1.5  
1
0.7  
0.5  
3
3
2
1.5  
1
0.8  
carrying  
metal parts  
and ground  
12 VDC  
24 VDC  
5
5
3
3
4
4
3
3
125 VDC  
250 VDC  
0.4  
0.4  
0.2  
0.2  
---  
---  
---  
---  
---  
---  
Rated insulation voltage 250 V  
(Ui)  
Note: 1. The above current ratings are for steady-state current.  
Pollution degree  
(application environment)  
3 (EN 60947-5-1)  
2. Inductive load has a power factor of 0.4 min. (AC) and a time  
constant of 7 ms max. (DC).  
Short-circuit protection  
device  
10-A fuse, gG or gI (IEC 269)  
3. Lamp load has an inrush current of 10 times the steady-  
state current.  
Conditional short-circuit 100 A (EN 60947-5-1)  
current  
4. Motor load has an inrush current of 6 times the steady-state  
current.  
Rated open thermal  
current (lth)  
5 A (EN 60947-5-1)  
Inrush current NC  
NO  
24 A max.  
12 A max.  
Electric shock protection Class I  
class  
Rated frequency  
50/60 Hz  
Ratings for Safety Standard  
Vibration  
Malfunction 10 to 55 Hz, 1.5-mm double amplitude  
Certification  
resistance  
(See note 4.)  
Shock  
Destruction 1,000 m/s2 (free position) min.  
CCC (GB14048.5), TÜV (EN60947-5-1)  
resistance  
Malfunction 300 m/s2 (operation limit position) min.  
(See note 4.)  
Category and rating  
Ambient operating  
temperature range  
20°C to 60°C (with no icing)  
AC-12: 250 VAC at 5 A, resistive load  
DC-12: 125 VDC at 0.4 A, resistive load  
Ambient operating  
humidity range  
90% max.  
UL (UL508, CSA C22.2 No. 14)  
Weight  
Approx. 130 to 190 g  
Ratings  
Note: 1. The above values are initial values.  
5 A, 250 VAC  
0.4 A, 125 VDC  
2. The above characteristics may vary depending on the  
model. Contact your OMRON representative for further  
details.  
3. Durability values are calculated at an operating temperature  
of 5°C to 35°C, and an operating humidity of 40% to 70%.  
4. Except for the coil spring model and wire spring model  
2
Small Limit Switch D4V  
Nomenclature  
Structure  
Contact Form  
Za  
Resin roller  
Lever  
(NO) 4  
3 (NO)  
2 (NC)  
(NC) 1  
Head  
4
NO  
1
3
NO  
2
Cover  
NC  
NC  
Built-in Switch  
Connector  
Engineering Data  
Electrical Durability: cos φ = 1  
(Ambient temperature: 5°C to 35°C; ambient humidity: 40% to 70%)  
Operating frequencies: 30 operations/min  
1,000  
125 VAC, cos φ = 1  
500  
0
1
2
3
4
5
6
Switching current (A)  
Small Limit Switch D4V  
3
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Roller Lever  
Rod Lever  
D4V-8104Z  
D4V-8107Z  
42.8±0.8  
39.6±0.8  
18-dia. × 6.2  
5.7  
2.6 dia. × 125.1  
35.6±  
0.8  
34.4±0.8  
(See note.)  
Four, M5,  
P=0.8,  
Depth:  
(See note.)  
Four, M5,  
P=0.8,  
Depth:  
M4 (length: 10),  
hexagonal hole  
7.5 min.  
115 max.  
7.5 min.  
Three, M3,  
P=0.5  
R30  
Three, M3,  
P=0.5  
M6 (length: 6),  
hexagonal hole  
18.3  
18.3  
M4  
12.5  
12.5  
(125.3)  
(length: 13),  
hexagonal  
hole  
56±0.2  
56±  
0.2  
64  
64  
Four, 4.2-dia  
mounting holes  
4
(14.3)  
Four, 4.2-dia  
mounting holes  
4
(14.3)  
(10.5)  
(3.45)  
7.2  
(10.5)  
(3.45)  
7.2  
14.7  
21  
±
0.2  
21  
±
0.2  
14.7  
25.4  
25.4  
27.8  
27.8  
37.5±0.8  
Note: Resin Roller  
Note: Stainless steel  
Adjustable Roller Lever  
Push Plunger  
D4V-8108Z  
D4V-8111Z  
Four, M5,  
6.6 dia. (See note.)  
R0.2  
46.5±0.8  
41.6±0.8  
18-dia. × 6.2  
10.4  
P=0.8,  
Depth:  
7.5 min.  
PT  
(See note.)  
Four, M5,  
3-M3*P0.5  
P=0.8,  
Depth:  
7.5 min.  
M4 (length: 10),  
hexagonal hole  
18.7  
OP  
Adjustable  
up to R30  
to R75  
Three, M3,  
P=0.5  
M6  
18.3  
(length: 6),  
(113.4)  
56±0.2  
12.5  
hexagonal  
hole  
64  
56±0.2  
64  
Four, 4.2-dia  
mounting holes  
4
(14.3)  
(10.5)  
7.2  
(3.45) 21  
±0.2  
14.7  
25.4  
4
Four, 4.2-dia  
mounting holes  
(14.3)  
27.8  
(10.5)  
(3.45)  
7.2  
Note: Stainless steel  
21  
±0.2  
14.7  
25.4  
27.8  
Note: Resin Roller  
44.7±0.8  
Roller Plunger  
Crossroller Plunger  
D4V-8112Z  
D4V-8122Z  
12.4-dia. × 3.9  
(See note.)  
10.4  
10.4  
Four, M5,  
P=0.8  
Four, M5,  
P=0.8,  
PT  
12.4 dia. × 3.9 (See note.)  
PT  
Depth:  
7.5 min.  
Depth:  
7.5 min.  
Three, M3, P=0.5  
Three, M3, P=0.5  
OP  
OP  
18.7  
18.7  
(113.4)  
(113.4)  
64  
56±0.2  
64  
56±0.2  
Four, 4.2-dia  
mounting holes  
Four, 4.2-dia  
mounting holes  
4
(10.5)  
(3.45)  
(14.3)  
4
(10.5)  
(3.45)  
(14.3)  
7.2  
7.2  
21  
±0.2  
14.7  
25.4  
21  
±0.2  
14.7  
25.4  
27.8  
27.8  
Note: Stainless steel  
Note: Stainless steel  
4
Small Limit Switch D4V  
Coil Spring  
Wire Spring  
D4V-8166Z  
D4V-8169Z  
PT  
3 dia.  
1.2 dia.  
(See note.)  
(See note.)  
83.5  
41.1  
Four, M5,  
P=0.8,  
Depth: 7.5 min.  
5.8 dia.  
Four, M5,  
P=0.8,  
Depth:  
100  
Three, M3,  
P=0.5  
Three, M3, P=0.5  
40  
7.5 min.  
13.6  
(176)  
(177)  
64  
56±0.2  
56±0.2  
64  
Four, 4.2-dia  
mounting holes  
4
(14.3)  
Four, 4.2-dia  
mounting holes  
4
(10.5)  
(3.45)  
(14.3)  
(10.5)  
(3.45)  
7.2  
7.2  
21  
±
0.2  
14.7  
25.4  
21  
±
0.2  
14.7  
25.4  
27.8  
27.8  
Note: The range for operation is between  
the tip of the rod and 1/3 of the length  
of the actuator.  
Note: The range for operation is between  
the tip of the rod and 1/3 of the length  
of the actuator.  
Note: Unless otherwise specified, the tolerances are ±0.4 mm for the above dimensions for each model.  
Operating Characteristics  
Model D4V-8104Z D4V-8107Z D4V-8108Z D4V-8111Z D4V-8112Z D4V-8122Z D4V-8166Z D4V-8169Z  
Operating characteristics  
Operating force  
Release force  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
TT min.  
OP  
5.88 N  
0.49 N  
20°  
75°  
10°  
5.88 N  
0.69 N  
20°  
75°  
10°  
7.84 N  
0.49 N  
20°  
75°  
10°  
9.8 N  
2.94 N  
1.5 mm  
4 mm  
9.8 N  
2.94 N  
1.5 mm  
4 mm  
9.8 N  
2.94 N  
1.5 mm  
4 mm  
0.88 N  
---  
0.88 N  
---  
Pretravel  
30 mm  
---  
30 mm  
---  
Overtravel  
Movement differential  
Total travel  
1.2 mm  
5.5 mm  
1.2 mm  
5.5 mm  
1.2 mm  
5.5 mm  
---  
---  
95°  
---  
95°  
---  
95°  
---  
---  
---  
Operating position  
26 0.8 mm 37 0.8 mm 37 0.8 mm  
---  
---  
Note: The operating characteristics of the D4V-8107 are measured with a lever length of 30 mm. The operating characteristics of the D4V-8108  
are measured with a lever length of R30.  
Small Limit Switch D4V  
5
Precautions  
Applicable Terminals  
The following solderless terminals can be used.  
Precautions for Correct Use  
(Do not use fork or any other type of terminals, otherwise an  
accidental disconnection resulting in a ground fault may result.)  
Wiring  
Terminal with insulated grip  
Wiring Procedure  
6.4 max.  
6.4 max.  
1. Loosen the cover mounting screws and remove the cover.  
2. Run the wiring through the rubber connector on the cover and  
then press-fit the solderless terminals. (The following solderless  
terminals are available.)  
3. After inserting the solderless terminal into the Switch, tighten the  
14 max.  
14 max.  
terminal screws securely.  
3.0 to 3.7 dia.  
3.0 to 3.7 dia.  
4. Mount the cover. (Make sure that the rubber connector is securely  
pressed into the cover slot.)  
5. Tighten the three screws evenly. (The optimum tightening torque  
for each screw is 0.49 to 0.59 N·m.)  
Appropriate Tightening Torque  
If screws are too loose, they can lead to an early malfunction of the  
Switch, so ensure that all screws are tightened using the correct  
torque.  
Cover mounting screw  
Cover  
No.  
Type  
Appropriate  
tightening  
torque  
1
2
3
4
5
Head mounting screw  
0.49 to 0.59 N·m  
0.49 to 0.59 N·m  
2.45 to 2.94 N·m  
0.49 to 0.59 N·m  
Cover mounting screw  
Lever mounting screw  
Terminal screw (M3)  
Rubber connector  
Terminals  
Switch mounting screw (M4 Allen-head bolt) 2.45 to 2.94 N·m  
Applicable Lead Wires  
Note: In particular, when changing the direction of the Head, make  
sure that all screws are tightened again to the correct torque.  
Be careful not to allow any foreign substance to enter the  
Switch.  
Wire name  
Applicable wire  
Number of Conductor Finished  
conductors  
size  
outside  
diameter  
0.75 mm2  
Vinyl cabtire cord (VCTF) 2 conductors  
3 conductors  
Round,  
6 to 9 dia.  
4 conductors  
1
0.75 mm2  
Vinyl cabtire cable (VCT) 2 conductors  
600-V vinyl-insulated  
sheath cable (VVF)  
2 conductors 1 dia.,  
3
1.2 dia.,  
1.6 dia.  
Note: Do not use wires containing silicone, otherwise a contact failure  
4
may result.  
2
5
6
Small Limit Switch D4V  
Mounting  
1. Front Surface Mounting  
2. Rear Surface Mounting  
1. Through-hole Panel Mounting  
Mounting Hole Diagram  
Four, 5.5 dia. holes  
M5 mounting  
bolt  
Mounting Hole Diagram  
Four, 4.5 dia. holes  
M4 mounting nut  
56±0.3  
M4 mounting bolt  
56±0.3  
21±0.3  
21±0.3  
Spring washer  
All units are in millimeters  
unless otherwise indicated.  
Spring washer  
All units are in millimeters  
unless otherwise indicated.  
Note: The tap screws for the body are M5, P=0.8, with a minimum  
depth of 7.5 mm. Use bolts with a length of the panel thickness  
t + 7 mm or less.  
2. Tap Panel Mounting  
Mounting Hole Diagram  
Others  
Four, M4 tapped holes  
(P=0.7)  
Do not use the Limit Switch outdoors, otherwise the Limit Switch  
M4 mounting bolt  
Spring washer  
will be damaged by rust or ozone.  
56±0.2  
The Limit Switch is not suitable in places exposed to the spray of  
rainwater, seawater, or oily water. Contact your OMRON  
representative if such specifications are required.  
21±0.2  
All units are in millimeters  
unless otherwise indicated.  
If high-sealing performance is required along with shielded wiring  
or conduit wiring, use the D4C or WL.  
Using the Switch  
Changing the Actuator Mounting  
Position  
Changing the Head Direction  
(D4V-8104Z, D4V-8107Z, D4V-8108Z)  
By loosening one screw (black) at a time, the head can be changed  
at 90° increments in any of the four directions.  
(D4V-8104Z, D4V-8108Z, D4V-8107Z)  
By loosening the Allen-head bolt on the actuator lever, the position of  
the actuator can be set anywhere within the 360°.  
Rotation screw  
(black)  
Operation  
Operate the coil spring and wire spring models between the tip of  
the actuator and 1/3 the length of the actuator and parallel to the  
direction of operation.  
Loosen the  
Allen-head  
bold.  
Handling the bottom of the actuator or excessively pushing in the  
tip may lead to bending damage, deformation, malfunction, and  
deterioration of service life.  
Contact bouncing, chattering, or telegraphing may occur.  
Take steps so that incorrect signals are not detected on the circuit  
side if doing so will cause problems with the application.  
Note: Telegraphing refers to the phenomenon of the actuator being  
used and bouncing back after the operating body has passed,  
and moving to the operation point on the opposite side, which  
causes the contact to operate.  
Small Limit Switch D4V  
7
READ AND UNDERSTAND THIS DOCUMENT  
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.  
WARRANTY  
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of  
sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS  
FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT  
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR  
IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY  
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S  
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO  
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
SUITABILITY FOR USE  
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF  
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate  
catalogs for OMRON's safety rated products.  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use  
of the product.  
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This  
information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other  
application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the  
products, nor is it intended to imply that the uses listed may be suitable for the products:  
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.  
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment,  
and installations subject to separate industry or government regulations.  
• Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A  
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED  
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PERFORMANCE DATA  
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of  
OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of  
Liability.  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some  
specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your  
application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or  
proofreading errors, or omissions.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.  
COPYRIGHT AND COPY PERMISSION  
This document shall not be copied for sales or promotions without permission.  
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in  
any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
Cat. No. C139-E1-01  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
Sensing Devices Division H.Q.  
Industrial Sensors Division  
Shiokoji Horikawa, Shimogyo-ku,  
Kyoto, 600-8530 Japan  
Tel: (81)75-344-7022/Fax: (81)75-344-7107  
Printed in Japan  
0306-2M (0306) (O)  

相关型号:

D4V-8112Z

Small Limit Switch
OMRON

D4V-8122Z

Small Limit Switch
OMRON

D4V-8166Z

Small Limit Switch
OMRON

D4V-8169Z

Small Limit Switch
OMRON

D4V5H1U2LP1610-7

Trans Voltage Suppressor Diode,
DIODES

D5-15

Analog IC
ETC

D5-15-230

Analog IC
ETC

D5-1C

DIODE NETWORKS D SERIES
TTELEC

D5-25

Analog IC
ETC

D5-25-230

Analog IC
ETC

D5-2C

DIODE NETWORKS D SERIES
TTELEC

D5-3C

DIODE NETWORKS D SERIES