D5A-5310 [OMRON]

Snap Acting/Limit Switch, SPST, Momentary, 1.5mm, Wire Terminal, Pin Plunger Actuator, Panel Mount;
D5A-5310
型号: D5A-5310
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap Acting/Limit Switch, SPST, Momentary, 1.5mm, Wire Terminal, Pin Plunger Actuator, Panel Mount

文件: 总8页 (文件大小:445K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
High-precision Switch  
D5A  
CSM_D5A_DS_E_2_1  
High-precision Switch for Detecting Micron-unit  
Displacement  
Ideal for detecting and measuring wear of cutting  
tools or for original point of work.  
Ceramic plungers on M5, M8, and slim models for  
superior abrasion resistance and resistance to  
temperature changes.  
Direct input possible to microprocessors and  
programmable controllers.  
A version with screw-type cable connector available  
for easy installation and maintenance.  
Be sure to read Safety Precautions on page 5 to 6 and Safety  
Precautions for All Limit Switches.  
Application Examples  
Origin Position Control of an X-Y Table  
Coaxiality Inspection  
Checking Turret Indexing Position  
Turret  
Motor  
D5A  
D5A  
D5A  
Motor  
D5A  
Origin can be set to a desired  
position and the origin position  
can be controlled using the D5A.  
Set the D5A on the turret index-  
ing position to check if the turret  
is engaged properly at the spec-  
ified position.  
The D5A can be mounted on a jig  
used for checking deviation to in-  
spect its coaxiality.  
Ordering Information  
Contact Output Models (NC Contact)  
Cable lead outlet  
Operation  
Indicator  
Operating force  
OF max.  
Degree of  
Model  
Actuator  
Type  
Repeat accuracy  
1 µm max.  
protection  
Lead outlet  
Length  
0.29 N  
0.49 N  
0.29 N  
0.49 N  
0.49 N  
0.98 N  
D5A-1100  
D5A-1200  
D5A-2100  
D5A-2200  
D5A-3200  
D5A-3300  
D5A-7400  
D5A-7403  
M5  
IP40  
IP67  
3 µm max.  
Pre-wired  
Pin plunger  
None  
1 m  
M8  
1 µm max.  
M16  
3 µm max.  
2.45 N  
Connector  
Solid-state Output Models (PNP Transistor Output)  
Cable lead outlet  
Operation  
Indicator  
Operating force  
OF max.  
Degree of  
protection  
Actuator  
Type  
M8  
Repeat accuracy  
Model  
Lead outlet  
Length  
0.49 N  
0.98 N  
0.49 N  
0.98 N  
D5A-3210  
D5A-3310  
D5A-5210  
D5A-5310  
D5A-7410  
D5A-7413  
D5A-8511  
D5A-8512  
D5A-8514  
D5A-8515  
D5A-9511  
D5A-9512  
D5A-9514  
D5A-9515  
1 µm max.  
Pre-wired  
Pin plunger  
Slim  
M16  
1 m  
3 µm max.  
2.45 N  
Connector  
Pre-wired  
3 m  
5 m  
3 m  
5 m  
3 m  
5 m  
3 m  
5 m  
Provided  
IP67  
Top plunger  
Bevel plunger  
Connector  
Pre-wired  
Connector  
Limit  
3 µm max.  
3.92 N  
1
D5A  
Specifications  
Ratings  
Characteristics  
Item  
Electrical ratings  
D5A-1@, D5A-2@: IP40  
Degree of protection  
Other than the above models: IP67  
M5, M8, M16 Type: 10 mA at 24 VAC  
10 mA at 12 VDC  
Contact output models  
M5 (D5A-1 @@@ series), M8, slim type:1  
M5 (D5A-2 @@@ series), M16, limit type:3 µm max.  
Mechanical 10,000,000 operations min.  
µm max.  
Repeat accuracy *1  
100 mA at 5 to 24 VDC 10%  
Leakage current: 0.15 mA max.  
Residual voltage: 3 V max.  
Solid-state output models  
1,000,000 operation min.  
Power consumption: 3 mW max.  
Durability *2  
(Contact output models: 24 VAC, 10 mA, resis-  
tive load, Solid-state output models: 24 VAC,  
100 mA, resistive load)  
Electrical  
Engineering Data  
Repeat Accuracy Examples (Reference Data)  
M5 Type (Contact Output) With  
Repeat Accuracy of 1 µm max.  
D5A-1@@@ Series  
Deviation in electrical  
durability after 1,000,000  
operations  
M5, M8, M16, slim type: 10 µm max.  
Limit type: 20 µm max.  
Operating speed  
Rated frequency  
1 µm/s to 0.5 m/s  
50/60 Hz  
100 Mmin. (at 250 VDC) between each termi-  
nal and non-current-carrying metal part  
Insulation resistance  
800 mmax. (initial) with 1 m cable,  
2.4 max. (initial) with 3 m cable,  
4 max. (initial) with 5 m cable  
Contact resistance  
(Initial value)  
1,000 VAC, 50/60 Hz for 1 min between each  
terminal and non-current-carrying metal part  
Dielectric strength  
Vibration  
Malfunction 10 to 55 Hz, 1.5-mm double amplitude  
resistance  
Mechanical 1,000 m/s2 min.  
Malfunction 300 m/s2 min.  
Shock  
resistance  
M5, M8, slim type: 20 × 10-6/°C max.  
Temperature coefficient  
*
3
M16 type: 40 × 10-6/°C max.  
Limit type: 50 × 10-6/°C max.  
Ambient operating  
temperature  
20°C to +75°C (with no icing)  
35% to 85%RH  
(35% to 95%RH with the seal rubber)  
Ambient operating humidity  
Note: The above figures are initial values.  
*1. Contact your OMRON sales representative for measurement conditions of  
the repeat accuracy.  
*2. Durability values are calculated at an operating temperature of +5°C to  
+35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON  
sales representative for more detailed information on other operating  
environments.  
*3. The value indicates the operating position change rate for a change of 1°C  
in the ambient temperature. The specifications depend on the model.  
Contact your OMRON sales representative for details.  
Structure and Nomenclature  
Structure  
Contact Form/Output Circuit Diagram  
Contact Output Models  
Seal rubber  
Case  
(NBR)  
Spring  
M5, M8, M16 type  
Nameplate  
Spring  
(NC)  
Note: NO Switches are not available with contact output models.  
Solid-state Output Models (PNP Transistor Output)  
M8, Slim, M16, Limit type  
Bearing  
Contact  
Contactor  
Cable  
(V-HKCVV)  
Plunger  
Load  
Brown (White)  
Blue (Black)  
Load  
HIC (hybrid integrated circuit)  
An LED current limit resistor is incorporated.  
The ZD absorbs surge.  
Note: The load may be connected to either the +V or 0 V terminal.  
Core wire colors have been changed accompanying changes in  
standards. The old core wire colors are given in parentheses.  
2
D5A  
Dimensions and Operating Characteristics  
(Unit: mm)  
M5 Type (Contact Output)  
M8 Type (Solid-state Output)  
D5A-1100 D5A-2100  
D5A-1200 D5A-2200  
D5A-3210  
D5A-3310  
S-FLEX V-HKCVV  
0.8  
equal level, 3 dia.  
Two conductors  
0.08 mm2 1m  
0.6  
13  
*1 OP  
(FP)  
4.85R  
2.5  
8
*1 OP  
(FP)  
2.5 M5 × 0.5  
M8 × 0.5 Operation indicator fiber,  
2 dia. (approx. 450 mm)  
3 dia.  
1.3 dia.  
2 dia.  
3 dia.  
3.7R  
10 dia.  
S-FLEX V-HKCVV  
equal level, 3 dia.  
Two conductors 0.08 mm2 1m  
Seal  
rubber  
15 dia.  
18  
Toothed lock washer Two clamping nuts  
Ceramic  
plunger  
21.5  
Ceramic  
plunger  
Toothed lock washer Two clamping nuts  
M8 Type (Contact Output)  
Slim Type (Solid-state Output)  
D5A-3200  
D5A-3300  
D5A-5210  
D5A-5310  
S-FLEX V-HKCVV  
equal level, 3 dia.  
Two conductors  
0.08 mm2 1m  
S-FLEX V-HKCVV  
Seal rubber  
Ceramic  
plunger  
0.8  
OP *1  
(FP)  
equal level, 3 dia.  
Two conductors  
0.08 mm2 1m  
Operation indicator (LED)  
13  
*1 OP  
(FP)  
2.5  
8
4.85R  
4
2 dia.  
3 dia.  
12  
5
3 dia.  
2 dia.  
Seal  
rubber  
15 dia.  
Two, 2.7+0.1 dia.  
4.85R  
0.2  
12  
20  
0
M8 × 0.5  
Toothed lock washer Two clamping nuts  
4
16.5  
Ceramic  
plunger  
M16 Type (Contact Output/Solid-state Output)  
M16 Type (Contact Output/Solid-state Output)  
D5A-7400  
D5A-7410  
D5A-7403  
D5A-7413  
(Connector type)  
1.2  
M16 × 0.5 (Length: 28.5)  
24  
4
1/8-inch  
Nameplate  
Operation indicator (LED) *3  
ultra-hard ball  
Operation indicator (LED) *3  
8 dia.  
3 dia.  
20  
26 dia.  
S-FLEX V-HKCVV  
equal level, 3 dia.  
Two conductors  
0.08 mm2 1m  
PT  
37.5  
45  
Toothed lock washer  
Note: 1. The dimensions are the same as the  
left model's.  
OP  
Two clamping nuts  
2. Cables with connectors are not sold  
separately.  
Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
2. Special screw dimensions apply to the case screws (pitch: 0.5 mm). Mounting is not possible with standard tapping. Use the provided special nuts.  
Operating  
characteristics  
Model D5A-1100  
D5A-2100  
D5A-1200  
D5A-2200  
D5A-3200  
D5A-3210  
D5A-3300  
D5A-3310  
D5A-7400, D5A-7410  
D5A-7403, D5A-7413  
*2  
*2  
*2  
*2  
D5A-5210  
*
2
D5A-5310 *2  
Operating force  
Pretravel  
Overtravel  
Movement  
Differential  
OF max.  
PT max.  
OT min.  
0.29 N  
---  
1.5 mm  
5 µm  
0.49 N  
---  
1.5 mm  
5 µm  
0.49 N  
---  
1.5 mm  
5 µm  
0.98 N  
---  
1.5 mm  
5 µm  
0.49 N  
---  
1.5 mm  
0.98 N  
---  
1.5 mm  
2.45 N  
1 mm  
2 mm  
5 µm  
5 µm  
5 µm  
MD max.  
Operating Position  
Free Position  
OP *1  
FP  
(2 mm)  
---  
(2 mm)  
---  
(6.5 mm)  
---  
(6.5 mm)  
---  
10.5 0.4 mm 10.5 0.4 mm  
--- ---  
(4.4 mm)  
(5 mm)  
*1. The operating position of these types is the same as the free position because of high sensitivity (repeat accuracy: 1 µm max.). This does not apply to M16 limit  
switch types.  
*2. Total movement is 1.9 to 2.1 mm. Set the appropriate stroke (plunging depth) to 1.0 to 1.5 mm from the FP.  
*3. Not available in the contact output type.  
3
D5A  
Limit Type (Solid-state Output)  
Limit Type (Solid-state Output)  
D5A-8511  
D5A-8512  
D5A-8514  
D5A-8515  
(Connector type)  
PT  
OP  
Two, 4.2 dia. holes 8 dia. spot facing depth: 5  
Operation indicator (LED)  
Two, M3 × 0.5  
3
6
Operation indicator (LED)  
Nameplate  
0.2  
0.2  
3 dia.  
30  
20  
15 dia. 8 dia.  
20  
20  
20  
S-FLEX V-HKCVV  
equal level, 3 dia.  
Two conductors  
0.08 mm2 3m/5m  
Note: 1. The dimensions are the same as the  
left model's.  
16  
10  
5
2. Cables with connectors are not sold  
separately.  
37.5  
45  
Limit Type (Solid-state Output)  
Limit Type (Solid-state Output)  
D5A-9511  
D5A-9512  
D5A-9514  
D5A-9515  
(Connector type)  
Operation indicator (LED)  
PT  
OP  
Two, 4.2 dia. holes 8 dia. spot facing depth: 5  
Two, M3 × 0.5  
3
6
Operation indicator (LED)  
Nameplate  
0.2  
0.2  
3 dia.  
30 20  
20  
15 dia. 8 dia.  
20  
20  
S-FLEX V-HKCVV  
equal level, 3 dia.  
Two conductors  
0.08 mm2 3m/5m  
Note: 1. The dimensions are the same as the  
left model's.  
16  
10  
5
37.5  
2. Cables with connectors are not sold  
separately.  
45  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
Operating  
characteristics  
Model  
D5A-8511, -8514  
D5A-8512, -8515  
D5A-9511, -9514  
D5A-9512, -9515  
Operating force  
Pretravel  
OF max.  
PT max.  
OT min.  
3.93 N  
1 mm  
5 mm  
5 µm  
3.93 N  
1 mm  
4 mm  
5 µm  
Overtravel  
Movement Differential MD max.  
Operating Position  
Free Position  
OP  
FP  
21.0 0.4 mm  
(21.8mm)  
15.2 0.4 mm  
(15.8mm)  
4
D5A  
Safety Precautions  
Refer to Safety Precautions for All Limit Switches.  
Precautions for Correct Use  
When mounting the Switch to a panel, be sure to use the toothed  
lock washer attached as an accessory (to M5, M8, and M16 types  
only). Use the washer on the panel surface opposite the object to  
be detected by the Switch.  
Handling of Fiber Cable  
Do not pull or impose any force exceeding 29.42 N on the fiber  
cable.  
Make sure that the bending radius of the fiber cable is as large as  
possible and at least R20 mm.  
The 40-mm portion of the fiber cable on the connector end as  
shown below must not be bent.  
Nut  
Object  
to be  
detected  
40 mm min.  
Toothed lock washer  
R20 mm min.  
Connection of Contact Output  
Do not impose compressing loads on the fiber cable.  
Load  
Fiber cable  
12 VDC  
10 mA  
Nylon clip  
D5A  
Load  
24 VAC  
10 mA  
D5A  
Consideration of polarity is not required.  
Connection of Solid-state Output  
The fiber cable can be cut with OMRON’s E39-F4 Cutting Tool.  
Do not impose any force exceeding 29.42 N on the cable, otherwise  
the cord may break. Make sure that the bending radius of the cable  
is at least 20 mm.  
Be sure to connect the load to the power source in series.  
The operating state of the Switch can be checked by the LED  
operation indicator (lights when the Switch is in operation)  
incorporated in the solid-state output circuit.  
The output residual voltage is approximately 3 V. Therefore,  
exercise care when selecting the load and setting the supply  
voltage. The residual voltage, however, can be easily calculated  
because it is almost constant and is free from the influence of  
fluctuation in the load current.  
Mounting  
The screw sections of cases for M5, M8, and M16 types have  
special dimensions. Do not use the mounting dimensions specified  
for standard types.  
For the mounting dimensions, refer to the following figures and  
tables.  
100 mA max.  
Brown (White)  
5 to 24 VDC  
Type  
M8  
M5  
M16  
Blue (Black)  
D5A  
Contact Solid-state  
Size  
output  
output  
5.2 0.1  
mm dia.  
16.2 0.1  
mm dia.  
Note: The lead wire colors of the D5A have been changed in compliance with  
the latest applicable JIS standards.  
Colors in parentheses are previous ones.  
[Example]  
(1) In the above circuit, suppose the MY relay rated at 12 VDC is used as the  
load. Since the must operate voltage of the relay is 80% or less than the  
rated voltage, it is 12 × 0.8 = 9.6 V. The supply voltage, in turn, is 3 + 9.6 =  
12.6 V.  
A (Mounting hole)  
B (Panel thickness)  
8.2 0.1 mm dia.  
5 to 8  
mm  
5 to 13  
mm  
3 to 10 mm  
10 mm dia.  
10 to 17 mm  
26 mm dia.  
C
15 mm dia.  
(Toothed lock washer)  
Therefore, the relay may not operate with a 12 V power source.  
(2) However, if the relay rated at 24 VDC is employed, the must operate voltage  
and supply voltage of the relay are respectively 19.2 V and 22.2 V. The relay  
therefore can operate with a 24 V power source.  
Type  
Slim  
Limit  
Size  
A
Mounting pitch  
Tapping  
Mounting hole 2.8 0.2 mm dia. 4.2 0.2 mm dia.  
12 0.2 mm  
M2.6  
20 0.2 mm  
M4  
When a solid-state circuit is turned OFF, leakage current of 0.15  
mA (max.) flows, causing some voltages to remain in the load. For  
this reason, be sure to check the must release voltage of the load  
before using it.  
B
0
0
Do not tighten the nut with too much force. Be sure to apply the  
torque shown in this table.  
Type  
M5  
Appropriate tightening torque  
0.98 N·m max.  
M8  
2.94 N·m max.  
M16  
Slim  
Limit  
9.81 N·m max.  
0.29 N·m max. (M2.6 screw)  
1.47 N·m max. (M4 screw)  
5
D5A  
Series Connection of Switches  
Others  
The Solid-state Output-type Switches must not be connected in  
series. To obtain the same effect as a series connection, form an AND  
gate with a relay inserted between the Switch and load.  
Adjust the mounting of the D5A until the stroke of the pin plunger  
and top plunger is aligned with the stroke of the operating body.  
Special attention should be paid to the ceramic pushbutton unit. It  
might be damaged if undue shock is applied.  
Load  
Brown (White)  
Blue (Black)  
D5A  
Brown (White)  
Blue (Black)  
D5A  
Load  
Brown  
Brown  
(White)  
(White)  
The harder the material for the dog and the more solidly the  
mounting base is fitted, the more accurately a minute displacement  
is detected.  
When a limit switch type (D5A-8 @@@, D5A-9 @@@) is used, apply  
grease to the dog to reduce friction between it and the plunger.  
Do not apply grease to pin plungers, otherwise the grease may  
stick to the contacts or generate gas that may cause contact  
failures.  
Be sure to use dogs made of hard materials for bevel or top  
plungers and apply grease to the surface of the dogs. The hardness  
(Hv) of a bevel plunger is 2,000 or over, for which it is  
recommended that a dog that has an Hv value of 1,000 or less be  
used.  
D5A  
D5A  
Blue  
Blue  
(Black)  
(Black)  
Parallel Connection of Switches  
In principle, two or more D5A's should not be used in an OR  
configuration.  
Brown (White) Brown (White)  
Load  
(A)  
(B)  
Do not fail to provide a stopper so as to prevent the enclosure of the  
D5A from being used as the stoppers.  
D5A  
D5A  
Blue (Black) Blue (Black)  
However, they can be connected in parallel provided that both  
switches A and B in the above figure do not operate at the same  
time and that the load does not have to be kept energized. In this  
circuit, however, the leakage current is increased, multiplied by the  
number of Switches connected in parallel. Consequently, the  
Switch may not release properly. To keep the load energized,  
connect a relay to each of the Switches as shown below.  
Dog  
Dog  
Stopper  
Stopper  
Attach an appropriate cover for the protection of the D5A from  
machining oil or cuttings. No protective cover is, however, provided  
together with the Switch.  
Exercise care that excessive force is not applied to the ceramic  
plunger of M5, M8, or slim type.  
Load  
Brown  
Brown  
(White)  
(White)  
If the possibility exists that strong shock may be applied to the  
plunger when the Switch is being mounted, use a protective cap.  
The plunger may not release if it is depressed with too great a force.  
Set its stroke by referring to the OT value indicated in Operating  
Characteristics.  
Blue  
(Black)  
Blue  
(Black)  
Connection to Power Source  
M5, M8  
Slim  
Be sure to connect the Switch to the power source via the load. If  
directly connected to the power source, the internal elements of the  
Switch may be damaged.  
Brown (White)  
Blue (Black)  
Do not mount the Switch with its nameplate facing downwards (i.e.,  
in the direction of gravity), otherwise the oil drain hole will not work  
effectively.  
Correctly connect the white and black lead wires to the positive and  
negative sides, respectively, of the power source. Although the  
D5A will not be damaged even if the polarity is reversed by mistake,  
if this happens, the Switch maintains the ON state (i.e., the contact  
is kept open) regardless of the presence or absence of the object  
to be detected.  
Oil drain hole  
Switch  
Nameplate  
Load  
Blue  
(Black)  
Always close  
Brown  
circuit  
(White)  
The core wire colors have been changed to meet new standards. Make sure  
that the wires are connected correctly.  
6
D5A  
7
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

D5A-7403

Snap Acting/Limit Switch, SPST, Momentary, 0.01A, 12VDC, 3mm, Connector Terminal, Pin Plunger Actuator, Panel Mount-threaded
OMRON

D5A-7410

Snap Acting/Limit Switch, SPST, Momentary, 3mm, Wire Terminal, Pin Plunger Actuator, Panel Mount-threaded
OMRON

D5A-7413

Snap Acting/Limit Switch, SPST, Momentary, 3mm, Connector Terminal, Pin Plunger Actuator, Panel Mount-threaded
OMRON

D5A9990-16303EFB-G

Parallel - Fundamental Quartz Crystal, 5.999MHz Nom, HC-49/U, 2 PIN
DBLECTRO

D5A9990-17302EFC-G

Parallel - Fundamental Quartz Crystal, 5.999MHz Nom, HC-49/U, 2 PIN
DBLECTRO

D5A9990-18301EFC-G

Parallel - Fundamental Quartz Crystal, 5.999MHz Nom, HC-49/U, 2 PIN
DBLECTRO

D5A9990-18305EFB-G

Parallel - Fundamental Quartz Crystal, 5.999MHz Nom, HC-49/U, 2 PIN
DBLECTRO

D5A9990-20302EFT-G

Parallel - Fundamental Quartz Crystal, 5.999MHz Nom, HC-49/U, 2 PIN
DBLECTRO

D5A9990-30301EFC-G

Parallel - Fundamental Quartz Crystal, 5.999MHz Nom, HC-49/U, 2 PIN
DBLECTRO

D5A9990-30306EFT-G

Parallel - Fundamental Quartz Crystal, 5.999MHz Nom, HC-49/U, 2 PIN
DBLECTRO

D5A9990-S303AFB-G

Series - Fundamental Quartz Crystal, 5.999MHz Nom, HC-49/U, 2 PIN
DBLECTRO

D5A9990C16301EFT-G

Parallel - Fundamental Quartz Crystal, 5.999MHz Nom, HC-49/U, 2 PIN
DBLECTRO