E2E-X2D2-M1TGJ-U0.3M [OMRON]
Standard Proximity Sensor; 标准接近传感器型号: | E2E-X2D2-M1TGJ-U0.3M |
厂家: | OMRON ELECTRONICS LLC |
描述: | Standard Proximity Sensor |
文件: | 总36页 (文件大小:2865K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Standard Proximity Sensor
E2E
CSM_E2E_DS_E_8_1
Your Search for Proximity Sensors
Starts with the World-leading
Performance and Quality of the E2E
• Standard Sensors for detecting ferrous metals.
• Wide array of variations. Ideal for a variety of applications.
• Models with different frequencies are also available to prevent
mutual interference.
• Superior environment resistance with standard cable made of oil-
resistant PVC and sensing surface made of material that resists
cutting oil.
• Useful to help prevent disconnection.
Cable protector provided as a standard feature.
*1, *2
*1: No AC/DC 2-wire models or AC 2-wire M8 models are compliant.
*2: Attach three ferrite clamps to the cable of the E2E-X3@@ and
E2E-X8MD@. (Refer to information on TDK catalog number
ZCAT2035-0930A.)
Be sure to read Safety Precautions on
page 27.
Features
2-Wire Models
Pre-wired Models with Oil-resistant Reinforced PUR Cables Added
to the Lineup and Easy Differentiation with Orange Head
Cable Flexibiliittyy at
Cable Flexibility
Low Temperatures
Oil Resistance
Differentiation from standard
models: Orange Head
Oil Resistance (Insulation service life):
twice or three times
that of oil-resistant vinyl chloride
Cable Flexibility:
approximately twice
that of cinyl chloride cables
More Flexibility at −40°C
Lineup includes models with Smartclick pre-wired connectors for fast connection.
XS5 Smartclick connectors used to
enable checking connector mating
Jacket: Polyester elastomer
Insert all
the way.
1/8 turn
Insulation: Oil-resistant grade PUR (polyurethane)
1
E2E
Lineup includes models with self-diagnostic output to provide notification of failures and
unstable detection conditions, such as coil burnout.
• Contributes to preventive maintenance to keep the line from stopping.
Reduced wiring, fewer resources, and low power consumption contribute to
environmentalism.
• Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models.
• Current consumption drastically reduced to less than 10% (when a DC 2-wire model is compared with a DC 3-wire model).
3-Wire Models
Lineup includes models with small diameter (3 dia., 4 dia., 5.4 dia., M5)
• All small-diameter models use sealed construction. Operation is stable even when the Sensor is mounted in a small space or embedded in metal.
• Bright indicators enable easily checking the installation condition.
Wide range of ambient operating temperatures: −40°C to 85°C (M8 to M30 models)
• Wide range of ambient operating temperatures also for small-diameter models: −25°C to 70°C
• Suitable for low-temperature and high-temperature applications, which are troublesome for photoelectric sensors.
Lineup includes models with flexible cable (4-dia. to M30 models)
• Reduced risk of disconnection in applications with moving parts.
2
E2E
Models Listed by E2E Type
●: Standard Models, ▲: Different frequency, @: Self-diagnosis, ■: Different frequency and self-diagnosis,
---: Not listed
2-Wire Models
Oil-resistant
reinforced
PUR cable
Standard cable and flexible cable
(cable material: oil-resistant PVC)/Connector models
Page
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
●
●
●
●
●
---
●
●
●
---
●
●
●
●
●
---
---
●
●
●
---
●
●
●
●
●
●
●
●
---
---
●
---
●
●
●
●
●
●
●
●
●
---
---
●
●
---
---
●
●
---
---
●
●
●
●
●
●
●
M8
2 m
Yes
Yes
No
●
Refer to
page 7.
●
●
●▲@■
●
●
●▲@
●
---
---
---
---
---
---
---
---
---
---
---
---
●
●
●
---
---
---
●
---
---
---
●
●
M12
3 mm
Refer to
Models
with Self-
diagnostic
Output on
page 8.
---
---
●
---
---
●
---
---
---
●
---
---
●▲@■
●
---
●▲@
●
Shield-
ed
Yes
No
●
●
---
---
---
●
---
---
---
●
●
M18
7 mm
Refer to
Models
---
---
●
---
---
●
---
---
---
●
---
with con-
ventional
connector
pin assign-
ments on
page 9.
---
---
●▲@■
●
●▲@
●
Yes
No
DC
●
●
---
---
---
---
---
●
---
---
---
●
---
---
---
●
M30
10 mm
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Refer to
page 8.
●
●
M8
4 mm
●
---
●
---
●
●
●
Refer to
Models
with Self-
diagnostic
Output or
Models
with con-
ventional
connector
pin assign-
ments on
page 9.
●▲@■
●
●▲@
●
---
---
---
---
---
M12
8 mm
---
●
---
●
---
●
Un-
shield-
ed
Yes
●▲@■
●
●▲@
●
M18
14 mm
---
●
---
●
---
●
●▲@■
●▲@
M30
20 mm
Refer
to page
29.
NC
---
---
---
●
---
---
●
---
---
●
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
●
●
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
●
---
---
●
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
M8
1.5 mm
●▲
●
M12
2 mm
---
●
●
Shield-
ed
●▲
●
●
M18
5 mm
---
●
●
●▲
●
●
M30
10 mm
---
---
---
●
●
AC
---
●
---
---
●
M8
2 mm
●
Refer
to page
10.
●▲
●
M12
5 mm
Un-
shield-
ed
---
---
---
---
---
---
---
●
●
●▲
●
●
M18
10 mm
●
●▲
●
●
M30
18 mm
●
●
---
---
---
---
---
---
M12
2 mm
---
●
Shield-
ed
M18
5 mm
AC/DC
---
---
●
---
---
---
M30
10 mm
---
3
E2E
●: Standard Models, ▲: Different frequency, ---: Not listed
3-Wire Models
Oil-resistant
reinforced
PUR cable
Standard cable and flexible cable
(cable material: oil-resistant PVC)/Connector models
Page
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
●
●
---
---
●
---
---
●
---
---
---
---
---
---
---
---
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
---
---
---
---
---
---
---
---
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
●
3 dia.
0.6 mm
●
4 dia.
0.8 mm
●
---
●
---
●
●
M5
1 mm
●
---
●
---
●
●
5.4 dia.
1 mm
Refer
to page
11.
●
---
●
---
●
Shield-
ed
●
M8
1.5mm
●
---
●
---
●
●
●▲
●
---
---
---
---
---
---
●
M12
2 mm
---
●
---
●
DC
Yes
NPN
●▲
●
M18
5 mm
---
●
---
●
●▲
●
M30
10 mm
---
●
---
---
---
●
●
M8
2 mm
●
---
●
●
●▲
●
---
---
---
---
---
---
---
---
---
---
---
---
---
---
●
M12
5 mm
Refer
topage
12.
Un-
shield-
ed
---
●
---
●
●▲
●
M18
10 mm
---
●
---
●
●▲
●
M30
18 mm
Refer
to page
29.
---
---
---
●
---
---
---
---
---
---
---
---
---
●
●
3 dia.
0.6 mm
●
●
4 dia.
0.8 mm
●
---
●
●
M5
1 mm
●
---
---
---
●
●
5.4 dia.
1 mm
Refer
to page
11.
●
Shield-
ed
●
M8
1.5mm
●
---
●
---
●
●
●▲
●
---
---
---
---
---
---
●
M12
2 mm
---
●
---
●
DC
PNP
Yes
●▲
●
M18
5 mm
---
●
---
---
---
---
---
---
---
---
---
---
---
●
M30
10 mm
●
---
●
●
M8
2 mm
●
---
●
●
●
---
---
---
---
---
---
M12
5 mm
Refer
topage
12.
Un-
shield-
ed
●
---
●
●
M18
10 mm
●
---
●
●
M30
18 mm
●
---
4
E2E
E2E Guide to Selection by Purpose
−40 to 85°C
AC 2-wire: M12 to M30,
DC 3-wire: M8 to M30
Wide operating
Environment
temperature range
−25 to 70°C
Models not listed above.
Resists the influence of surrounding metal
Shielded Models
DC 2-Wire Models
E2E-X@D@
Reducing stocked
NPN/PNP output
Maintenance
models
AC/DC 2-Wire Models
E2E-X@T1
AC/DC
Smartclick Pre-wired
Connector Models
E2E-X@D@-M1TGJ-(U)
Easy replacement
Pre-wired Connector
Models
E2E-X@D1-M1(G)J-(T)
Connector Models
E2E-X@D@-M1(G)
E2E-X@E@-M1
E2E-X@Y@-M1
Reinforced
Standard
Models with Oil-resistor
reinforced PUR cable
E2E-X@D@-U
Higher oil resistance
Reducing troubles
Models with Oil-resistant PVC
cable
Mounting to moving
Robotics Cable Models
E2E-X@D1-R
parts
Robotics cable
E2E-X@E1-R
Mutual interference
prevention
Models with a Different
Frequency (NO Models
only)
E2E-X@@15
Load short-circuit
DC 2-Wire Models
E2E-X@D@
Miswiring measures
protection
DC 3-Wire Models
E2E-X@E@
DC 2-Wire
No-polarity Models
E2E-X@D1-M1J-T
No polarity
Early discovery
of problems
Diagnostic Models
E2E-X@D1S
Note: Refer to Models Not Listed in this Catalog for Long Body Models, Transmission Couplers, and Power Couplers.
5
E2E
E2E Model Number Legend
A B C D E F G - H I - J - K - L
M
E2E-
No.
Classification
Code
Meaning
Remarks
C
X
Cylindrical (not threaded)
Cylindrical (threaded)
A
B
C
Appearance
Number
Sensing distance (Unit: mm)
Example:
R6: 0.6 mm
1R5: 1.5 mm
Sensing distance
Shielding
R
Indication of decimal point
Blank
Shielded Models
M
Unshielded Models
B
DC 3-wire PNP open-collector output
DC 3-wire NPN open-collector output
DC 2-wire polarity/no polarity
DC 3-wire NPN collector load built-in output
DC 3-wire PNP collector load built-in output
AC/DC 2-wire
C
D
Whether D models have
polarity is defined by num-
ber J.
Power supply and output
specifications
D
E
F
T
Y
AC 2-wire
1
2
Normally open (NO)
Form of output switching el-
ement
E
F
G
Normally closed (NC)
Standard frequency
Blank
5
Used to prevent mutual in-
terference.
Oscillation frequency type
Self-diagnosis
Different frequency
Blank
5
No
Yes
Blank
M1
Pre-wired
H
Connection method
M12-size metal connector
M8-size metal connector
M3
Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output,
DC 2-wire with old pin arrangement (polarity)
Blank
G
Connector Models
DC 2-wire with IEC pin arrangement (polarity)
Pre-wired Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with IEC pin arrangement
(polarity), DC 3-wire and AC 2-wire, DC 2-wire with self-diagno-
sis output, DC 2-wire with old pin arrangement (polarity)
J
I
Connector specifications
Pre-wired Connector Models
DC 2-wire with IEC pin arrangement (polarity)
GJ
TJ
Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (no polarity)
Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (polarity)
TGJ
Blank
T
Polarity
J
K
DC 2-wire polarity
No polarity
Blank
R
Standard PVC cable (oil resistant)
Flexible PVC cable (oil resistant)
Polyurethane cable (oil resistant and reinforced)
Cable specifications
U
This is blank if the cable
specification in number K
is R or U.
New model (Applies only to DC 2-wire pre-wired and shielded
models.)
L
M
New model
N
Example:
2M
0.3M
Cable length (Unit: m) (Applicable to Pre-wired Models and Pre-
wired Connector Models.)
Cable length
Letter M
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
Models are not available for all combinations of code numbers.
Ask your OMRON representative if you require a customized model.
6
E2E
Ordering Information
2-Wire Models
Shielded DC 2-wire Models with No Self-diagnostic Output [Refer to Dimensions on page 29.]
Opera-
Applicable
connector
code *4
Appear-
ance
Connection
method
Cable
specifications
Polar-
ity
Pin
arrangement
Sensing distance
tion
Model
mode
NO
NC
NO
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
E2E-X2D1-M1TGJ-U 0.3M
E2E-X2D2-M1TGJ-U 0.3M
E2E-X2D1-M1TGJ 0.3M
E2E-X2D1-U 2M
PUR (increased
oil-resistant)
M12 Pre-wired Smart-
click Connector Mod-
els (0.3m)
H
G
PVC (oil-resistant)
PUR (increased
oil-resistant)
E2E-X2D2-U 2M
Pre-wired Models
(2 m)
---
---
M8
Yes
E2E-X2D1-N 2M *2*3
E2E-X2D2-N 2M *3
E2E-X2D1-M1G
2 mm
PVC (oil-resistant)
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
M12 Connector Mod-
els
---
---
E2E-X2D2-M1G
E2E-X2D1-M3G
M8 Connector Models
I
E2E-X2D2-M3G
E2E-X3D1-M1TGJ-U 0.3M
E2E-X3D2-M1TGJ-U 0.3M
E2E-X3D1-M1TGJ 0.3M
E2E-X3D1-U 2M
PUR (increased
oil-resistant)
M12 Pre-wired Smart-
click Connector Mod-
els (0.3m)
H
G
PVC (oil-resistant)
PUR (increased
oil-resistant)
Yes
E2E-X3D2-U 2M
Pre-wired Models
(2 m)
---
---
E2E-X3D1-N 2M *1*2*3
E2E-X3D2-N 2M *3
E2E-X3D1-M1G *1
PVC (oil-resistant)
---
M12
3 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
(3, 4): (+V, 0 V)
(1, 2): (+V, 0 V)
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
A
D
C
D
M12 Connector Mod-
els
E2E-X3D2-M1G
E2E-X3D1-M1GJ 0.3M
E2E-X3D2-M1GJ 0.3M
E2E-X3D1-M1J-T 0.3M
---
E2E-X7D1-M1TGJ-U 0.3M
E2E-X7D2-M1TGJ-U 0.3M
E2E-X7D1-M1TGJ 0.3M
E2E-X7D1-U 2M
Yes
M12 Standard Pre-
wired Connector Mod- PVC (oil-resistant)
els (0.3 m) *6
No *5
PUR (increased
oil-resistant)
M12 Pre-wired Smart-
H
G
click Connector Mod-
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
Yes
E2E-X7D2-U 2M
Pre-wired Models
(2 m)
---
---
E2E-X7D1-N 2M *1*2*3
E2E-X7D2-N 2M *3
E2E-X7D1-M1G *1
PVC (oil-resistant)
M18
7 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
(3, 4): (+V, 0 V)
(1, 2): (+V, 0 V)
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
A
D
C
D
M12 Connector Mod-
els
---
E2E-X7D2-M1G
E2E-X7D1-M1GJ 0.3M
E2E-X7D2-M1GJ 0.3M
E2E-X7D1-M1J-T 0.3M
E2E-X7D2-M1J-T 0.3M
E2E-X10D1-M1TGJ-U 0.3M
E2E-X10D2-M1TGJ-U 0.3M
E2E-X10D1-M1TGJ 0.3M
E2E-X10D1-U 2M
Yes
M12 Standard Pre-
wired Connector Mod- PVC (oil-resistant)
els (0.3 m) *6
No *5
PUR (increased
oil-resistant)
M12 Pre-wired Smart-
H
G
click Connector Mod-
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
Yes
E2E-X10D2-U 2M
Pre-wired Models
(2 m)
---
---
E2E-X10D1-N 2M *1*2*3
E2E-X10D2-N 2M
PVC (oil-resistant)
M30
10 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
(3, 4): (+V, 0 V)
(1, 2): (+V, 0 V)
A
D
A
D
C
D
E2E-X10D1-M1G *1
E2E-X10D2-M1G
M12 Connector Mod-
els
---
E2E-X10D1-M1GJ 0.3M
E2E-X10D2-M1GJ 0.3M
E2E-X10D1-M1J-T 0.3M
E2E-X10D2-M1J-T 0.3M
Yes
M12 Standard Pre-
wired Connector Mod- PVC (oil-resistant)
els (0.3 m) *6
No *5
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X3D15-N 2M).
*2. Models with a flexible cable are also available. Add "-R" rather than "-N" to the end of the model number (example: E2E-X2D1-R 2M).
*3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X3D1-N 5M)
*4. Refer to page 24 for details.
*5. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage). Refer to page 28.
*6. The standard cable length is 300 mm. Cables with a length of 500 mm and 1 m can also be manufactured.
7
E2E
2-Wire Models
Unshielded DC 2-Wire Models with No Self-diagnosis Output [Refer to Dimensions on page 29.]
Opera-
tion
mode
Applicable
connector
code *4
Appear-
ance
Connection
method
Cable
specifications
Polar-
ity
Pin
arrangement
Sensing distance
Model
NO
NC
NO
NC
NO
NC
E2E-X4MD1 2M *2*3
E2E-X4MD2 2M
Pre-wired Models (2 m) PVC (oil-resistant)
---
---
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
A
D
E2E-X4MD1 2M
M8
M12 Connector Models
---
---
4 mm
E2E-X4MD2-M1G
E2E-X4MD1-M3G
E2E-X4MD2-M3G
M8 Connector Models
12M Pre-wired Smart-
click Connector Models PVC (oil-resistant)
(0.3m)
I
NO
1: +V, 4: 0 V
---
G
---
E2E-X8MD1-M1TGJ 0.3M
NO
NC
NO
NC
NO
E2E-X8MD1 2M *1*2*3
E2E-X8MD2 2M
Pre-wired Models (2 m) PVC (oil-resistant)
M12
8 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
A
E2E-X8MD1-M1G *1
E2E-X8MD2-M1G
M12 Connector Models
M12 Standard Pre-
---
E2E-X8MD1-M1GJ 0.3M
wired Connector Mod- PVC (oil-resistant)
els (0.3 m)
NC
1: +V, 2: 0 V
D
---
12M Pre-wired Smart-
click Connector Models PVC (oil-resistant)
(0.3m)
NO
1: +V, 4: 0 V
G
E2E-X14MD1-M1TGJ 0.3M
Yes
NO
NC
NO
NC
NO
E2E-X14MD1 2M *1*2*3
E2E-X14MD2 2M
Pre-wired Models (2 m) PVC (oil-resistant)
---
---
M18
14 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
A
E2E-X14MD1-M1G *1
E2E-X14MD2-M1G
M12 Connector Models
M12 Standard Pre-
---
E2E-X14MD1-M1GJ 0.3M
wired Connector Mod- PVC (oil-resistant)
els (0.3 m)
NC
1: +V, 2: 0 V
D
E2E-X14MD2-M1GJ 0.3M
12M Pre-wired Smart-
click Connector Models PVC (oil-resistant)
(0.3m)
NO
1: +V, 4: 0 V
G
E2E-X20MD1-M1TGJ 0.3M
NO
NC
NO
NC
NO
E2E-X20MD1 2M *1*2*3
E2E-X20MD2 2M
Pre-wired Models (2 m) PVC (oil-resistant)
---
---
M30
20 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
A
E2E-X20MD1-M1G *1
E2E-X20MD2-M1G
M12 Connector Models
M12 Standard Pre-
---
E2E-X20MD1-M1GJ 0.3M
wired Connector Mod- PVC (oil-resistant)
els (0.3 m)
NC
1: +V, 2: 0 V
D
---
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X8MD15 2M).
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X4MD1-R 2M).
*3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X4MD1 5M)
*4. Refer to page 24 for details.
Shielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]
Opera-
tion
mode
Applicable
connector
code *2
Appear-
ance
Connection
method
Cable
specifications
Polar-
ity
Pin
arrangement
Sensing distance
Model
Pre-wired Models
(2 m)
PVC (oil-resistant)
---
---
E2E-X3D1S 2M *1
E2E-X3D1S-M1
E2E-X7D1S 2M *1
E2E-X7D1S-M1
E2E-X10D1S 2M *1
E2E-X10D1S-M1
M12
M18
M30
3 mm
2: +V and diagnostic output
3: 0 V
4: +V and control output
M12 Connector
Models
---
D
Pre-wired Models
(2 m)
PVC (oil-resistant)
---
---
D
Yes
NO
7 mm
2: +V and diagnostic output
3: 0 V
4: +V and control output
M12 Connector
Models
---
PVC (oil-resistant)
---
Pre-wired Models
(2 m)
---
---
D
10 mm
2: +V and diagnostic output
3: 0 V
4: +V and control output
M12 Connector
Models
*1. Models with different frequencies are also available. The model number is E2E-X @D15S (example: E2E-X3D15S 2M).
*2. Refer to page 24 for details.
8
E2E
2-Wire Models
Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 29.]
Opera-
Applicable
connector
code *2
Appear-
ance
Connection
method
Cable
specifications
Polar-
ity
Pin
arrangement
Sensing distance
tion
Model
mode
Pre-wired Mod-
els (2 m)
PVC (oil-resistant)
---
---
E2E-X8MD1S 2M *
E2E-X8MD1S-M1
E2E-X14MD1S 2M *
E2E-X14MD1S-M1
E2E-X20MD1S 2M *
E2E-X20MD1S-M1
M12
M18
M30
8 mm
2: +V and diagnostic output
3: 0 V
4: +V and control output
M12 Connector
Models
---
D
Pre-wired Mod-
els (2 m)
PVC (oil-resistant)
---
---
D
Yes
NO
14 mm
2: +V and diagnostic output
3: 0 V
4: +V and control output
M12 Connector
Models
---
PVC (oil-resistant)
---
Pre-wired Mod-
els (2 m)
---
---
D
20 mm
2: +V and diagnostic output
3: 0 V
4: +V and control output
M12 Connector
Models
*1. Models with different frequencies are also available. The model number is E2E-X @MD15S (example: E2E-X8MD15S 2M).
*2. Refer to page 24 for details.
Connector Pin Assignments of DC 2-Wire Models
• The connector pin assignments of each New E2E DC 2-Wire Model
Cable length
Model
XS2W-D421-BY1
conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have
been changed in comparison to the previous models.)
• The following models with conventional connector pin assignments
are available as well. (Only NO Models can be used.)
The cable at the right should also be used if the XW3A-P@45-G11
Connector Junction Box is already being used.
500 mm
Internal Wiring
(Proximity Sensor end)
(Wired end)
1
4
4
3
Models with conventional connector pin assignments are available as well.
Appearance
Model
NO
Applicable connector code *
NC
Applicable connector code *
M8
E2E-X2D1-M1
C
C
C
C
C
C
C
C
E2E-X2D2-M1
D
Shielded
M12
M18
M30
M8
E2E-X3D1-M1
E2E-X3D2-M1
D
D
D
D
D
D
D
E2E-X7D1-M1
E2E-X7D2-M1
E2E-X10D1-M1
E2E-X4MD1-M1
E2E-X8MD1-M1
E2E-X14MD1-M1
E2E-X20MD1-M1
E2E-X10D2-M1
E2E-X4MD2-M1
E2E-X8MD2-M1
E2E-X14MD2-M1
E2E-X20MD2-M1
Unshielded
M12
M18
M30
Note: Refer to page 24 for details.
9
E2E
2-Wire Models
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]
Appear-
ance
Connection
method
Cable
specifications
Operation
mode
Pin
arrangement
Applicable con-
nector code *3
Sensing distance
Model
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
E2E-X1R5Y1 2M
E2E-X1R5Y2 2M
E2E-X2Y1 2M *1*2
E2E-X2Y2 2M
Pre-wired Models
(2 m)
M8
PVC (oil-resistant)
---
---
---
---
1.5 mm
Pre-wired Models
(2 m)
PVC (oil-resistant)
M12
2 mm
(3, 4): (AC, AC)
(1, 2): (AC, AC)
E
F
E2E-X2Y1-M1
M12 Connector
Models
---
E2E-X2Y2-M1
E2E-X5Y1 2M *1*2
E2E-X5Y2 2M
Pre-wired Models
(2 m)
PVC (oil-resistant)
---
---
M18
M30
5 mm
(3, 4): (AC, AC)
(1, 2): (AC, AC)
E
F
E2E-X5Y1-M1
M12 Connector
Models
---
PVC (oil-resistant)
---
E2E-X5Y2-M1
E2E-X10Y1 2M *1*2
E2E-X10Y2 2M
E2E-X10Y1-M1
E2E-X10Y2-M1
Pre-wired Models
(2 m)
---
---
10 mm
(3, 4): (AC, AC)
(1, 2): (AC, AC)
E
F
M12 Connector
Models
*1. Models with different frequencies are also available. The model number is E2E-X @Y@5 (example: E2E-X5Y15 2M).
*2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2Y1 5M)
*3. Refer to page 24 for details.
Unshielded Models
Appear-
ance
Connection
method
Cable
Operation
mode
Pin
Applicable con-
nector code *3
Sensing distance
Model
E2E-X2MY1 2M
E2E-X2MY2 2M
specifications
arrangement
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
Pre-wired Models
(2 m)
M8
PVC (oil-resistant)
---
---
---
---
2 mm
E2E-X5MY1 2M *1*2
E2E-X5MY2 2M
Pre-wired Models
(2 m)
PVC (oil-resistant)
M12
5 mm
(3, 4): (AC, AC)
(1, 2): (AC, AC)
E
F
E2E-X5MY1 2M
M12 Connector
Models
---
E2E-X5MY2-M1
E2E-X10MY1 2M *1
E2E-X10MY2 2M
E2E-X10MY1-M1
E2E-X10MY2-M1
E2E-X18MY1 2M *1
E2E-X18MY2 2M
E2E-X18MY1-M1
E2E-X18MY2-M1
Pre-wired Models
(2 m)
PVC (oil-resistant)
---
---
M18
M30
10 mm
(3, 4): (AC, AC)
(1, 2): (AC, AC)
E
F
M12 Connector
Models
---
PVC (oil-resistant)
---
Pre-wired Models
(2 m)
---
---
18 mm
(3, 4): (AC, AC)
(1, 2): (AC, AC)
E
F
M12 Connector
Models
*1. Models with different frequencies are also available. The model number is E2E-X @MY@5 (example: E2E-X5MY15 2M).
*2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5MY1 5M)
*3. Refer to page 24 for details.
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 29.]
(There are no unshielded models.)
Appear-
ance
Connection
method
Cable
Operation
mode
Pin
Applicable con-
nector code *3
Sensing distance
Model
E2E-X3T1 2M
specifications
arrangement
Pre-wired Models PVC (oil-resis-
(2 m) tant)
M12
M18
M30
---
---
---
---
---
---
3 mm
7 mm
Pre-wired Models PVC (oil-resis-
(2 m) tant)
NO
E2E-X7T1 2M *
E2E-X10T1 2M
Pre-wired Models PVC (oil-resis-
(2 m) tant)
10 mm
Note: Not compliant with CE.
* The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X7T1 5M)
10
E2E
3-Wire Models
Shielded DC 3-Wire Models [Refer to Dimensions on page 29.]
Appli-
cable
connec-
torcode
*5
Model
Cable
specifica-
tions
Opera-
Appear-
ance
Connection
method
Pin
arrangement
Sensing distance
tion
NPN output
PNP output
mode
NO
NC
NO
NC
NO
NC
NO
NC
E2E-CR6C1 2M
E2E-CR6C2 2M
E2E-CR8C1 2M *1*2
E2E-CR8C2 2M
E2E-X1C1 2M *1*2
E2E-X1C2 2M
E2E-CR6B1 2M
E2E-CR6B2 2M
E2E-CR8B1 2M *2
E2E-CR8B2 2M
E2E-X1B1 2M *2
E2E-X1B2 2M
Pre-wired Models PVC (oil-re-
(2 m) sistant)
3 dia.
4 dia.
M5
---
---
---
---
---
---
---
---
0.6 mm
Pre-wired Models PVC (oil-re-
(2 m) sistant)
0.8 mm
1 mm
Pre-wired Models PVC (oil-re-
(2 m) sistant)
E2E-C1C1 2M *1*2
E2E-C1C2 2M
E2E-C1B1 2M
Pre-wired Models PVC (oil-re-
5.4 dia.
1 mm
(2 m)
sistant)
E2E-C1B2 2M
PVC (oil-re-
sistant)
NO
NC
NO
NC
NO
NC
E2E-X1R5E1 2M *1*2 E2E-X1R5F1 2M *1*2
Pre-wired Models
(2 m)
---
---
PVC (oil-re-
sistant)
E2E-X1R5E2 2M
E2E-X1R5E1-M1
E2E-X1R5E2-M1
E2E-X1R5E1-M3
E2E-X1R5E2-M3
E2E-X1R5F2 2M
E2E-X1R5F1-M1
E2E-X1R5F2-M1
E2E-X1R5F1-M3
E2E-X1R5F2-M3
1: +V, 3: 0 V,
4: Control output
B
D
M12 Connector
Models
M8
---
---
1.5 mm
1: +V, 3: 0 V,
2: Control output
1: +V, 3: 0 V,
4: Control output
M8 Connector
Models
I
1: +V, 3: 0 V,
2: Control output
NO
NC
E2E-X2E1 2M *1*2*3
E2E-X2E2 2M
E2E-X2F1 2M *1*2*3
E2E-X2F2 2M
Pre-wired Models PVC (oil-re-
---
---
(2 m)
sistant)
1: +V, 3: 0 V,
M12
M18
M30
2 mm
5 mm
NO
NC
E2E-X2E1-M1
E2E-X2E2-M1
E2E-X2F1-M1
E2E-X2F2-M1
B
D
4: Control output
M12 Connector
Models
---
1: +V, 3: 0 V,
2: Control output
NO
NC
E2E-X5E1 2M *1*2*3
E2E-X5E2 2M
E2E-X5F1 2M *1*2*3
E2E-X5F2 2M
Pre-wired Models PVC (oil-re-
(2 m)
---
---
sistant)
1: +V, 3: 0 V,
4: Control output
NO
NC
E2E-X5E1-M1
E2E-X5E2-M1
E2E-X5F1-M1
E2E-X5F2-M1
B
D
M12 Connector
Models
---
1: +V, 3: 0 V,
2: Control output
NO
NC
E2E-X10E1 2M *1*2*3 E2E-X10F1 2M *2
Pre-wired Models PVC (oil-re-
(2 m)
---
---
sistant)
E2E-X10E2 2M
E2E-X10F2 2M
1: +V, 3: 0 V,
4: Control output
10 mm
NO
NC
E2E-X10E1-M1
E2E-X10F1-M1
B
D
M12 Connector
Models
---
1: +V, 3: 0 V,
2: Control output
E2E-X10E2-M1
E2E-X10F2-M1
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2E1 5M)
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M).
*3. Models with different frequencies are also available. The model number is E2E-X@@@5 (example: E2E-X5E15 2M).
*4. Refer to page 24 for details.
11
E2E
3-Wire Models
Unshielded DC 3-Wire Models [Refer to Dimensions on page 29.]
Appli-
cable
connec-
torcode
*5
Model
Opera-
tion
mode
Appear-
ance
Connection
method
Cable
specifications
Pin
arrangement
Sensing distance
NPN output
PNP output
NO
NC
E2E-X2ME1 2M *2 E2E-X2MF1 2M *2
Pre-wired Models PVC (oil-resis-
---
---
(2 m)
tant)
E2E-X2ME2 2M
E2E-X2ME1-M1
E2E-X2MF2 2M
E2E-X2MF1-M1
1: +V, 3: 0 V,
4: Control output
NO
NC
NO
NC
B
D
M12 Connector
Models
---
---
1: +V, 3: 0 V,
2: Control output
M8
2 mm
E2E-X2ME2-M1
E2E-X2ME1-M3
E2E-X2ME2-M3
E2E-X2MF2-M1
E2E-X2MF1-M3
E2E-X2MF2-M3
1: +V, 3: 0 V,
4: Control output
M8 Connector
Models
I
1: +V, 3: 0 V,
2: Control output
E2E-X5ME1 2M
*1*2*3
NO
NC
NO
E2E-X5MF1 2M *2
E2E-X5MF2 2M
E2E-X5MF1-M1
Pre-wired Models PVC (oil-resis-
---
---
(2 m)
tant)
E2E-X5ME2 2M
M12
M18
M30
5 mm
1: +V, 3: 0 V,
4: Control output
E2E-X5ME1-M1
B
D
M12 Connector
Models
---
1: +V, 3: 0 V,
2: Control output
NC
E2E-X5ME2-M1
E2E-X5MF2-M1
E2E-X10ME1 2M
*1*2*3
NO
NC
NO
E2E-X10MF1 2M *2
E2E-X10MF2 2M
E2E-X10MF1-M1
Pre-wired Models PVC (oil-resis-
---
---
(2 m)
tant)
E2E-X10ME2 2M
10 mm
1: +V, 3: 0 V,
4: Control output
E2E-X10ME1-M1
B
D
M12 Connector
Models
---
1: +V, 3: 0 V,
2: Control output
NC
E2E-X10ME2-M1
E2E-X10MF2-M1
E2E-X18ME1 2M
*1*2*3
NO
NC
NO
E2E-X18MF1 2M *2
E2E-X18MF2 2M
E2E-X18MF1-M1
Pre-wired Models PVC (oil-resis-
---
---
(2 m)
tant)
E2E-X18ME2 2M
18 mm
1: +V, 3: 0 V,
4: Control output
E2E-X18ME1-M1
B
D
M12 Connector
Models
---
1: +V, 3: 0 V,
2: Control output
NC
E2E-X18ME2-M1
E2E-X18MF2-M1
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5ME1 5M)
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M).
*3. Models with different frequencies are also available. The model number is E2E-X@M@@5 (example: E2E-X5ME15 2M).
*4. Refer to page 24 for details.
12
E2E
Ratings and Specifications
E2E-X@D@ DC 2-Wire Models
Size
M8
M12
M18
M30
Shielded
Shielded
Unshielded
Shielded
E2E-X3D@
3 mm 10%
0 to 2.4 mm
Unshielded
Shielded
E2E-X7D@
7 mm 10%
0 to 5.6 mm
Unshielded
Shielded
Unshielded
Item
Model E2E-X2D@
E2E-X4MD@
4 mm 10%
0 to 3.2 mm
E2E-X8MD@
8 mm 10%
0 to 6.4 mm
E2E-X14MD@ E2E-X10D@
E2E-X20MD@
20 mm 10%
0 to 16 mm
Sensing distance
Set distance *1
2 mm 10%
0 to 1.6 mm
14 mm 10%
0 to 11.2 mm
10 mm 10%
0 to 8 mm
Differential travel
Detectable object
15% max. of sensing distance
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.
Standard sensing
object
Iron,
8 × 8 × 1 mm
Iron,
Iron,
Iron,
Iron,
Iron,
54 × 54 × 1 mm
Iron, 30 × 30 × 1 mm
20 × 20 × 1 mm 12 × 12 × 1 mm 30 × 30 × 1 mm 18 × 18 × 1 mm
Response frequency
*2
1.5 kHz
1 kHz 0.8 kHz 0.5 kHz
0.4 kHz
0.1 kHz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current
0.8 mA max.
Load
current
3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
Control
output
Residual
voltage
*3
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
Indicators
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.
Diagnostic output
delay
0.3 to 1 s
Protection circuits
Surge suppressor, Load short-circuit protection (for control and diagnostic output)
Ambient
temperature range
Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Ambient
Operating/storage: 35% to 95% (with no condensation)
15% max. of sensing distance
humidity range
Temperature
influence
at 23°C in the temperature range
10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
of −25 to 70°C
Voltage influence
1% max. of sensing distance at rated voltage in the rated voltage 15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
Vibration resistance
1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2
Shock resistance
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Degree of protection
Connection method
Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
Pre-wired
Models
Approx. 60 g
Approx. 70 g
Approx. 40 g
Approx. 130 g
Approx. 70 g
Approx. 40 g
Approx. 175 g
Approx. 110 g
Approx. 90 g
Weight
Pre-wired
(pack-
Connector
ed
---
Models
state)
Connector
Models
Approx. 15 g
Approx. 25 g
Case
Stainless steel (SUS303)
PBT
Nickel-plated brass
Sensing sur-
face
Materi-
als
Clamping
nuts
Nickel-plated brass
Toothed
washer
Zinc-plated iron
Accessories
Instruction manual
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 28 for
details.)
13
E2E
E2E-X@Y@ AC 2-Wire Models
Size
M8
M12
M18
M30
Shielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Item
Model E2E-X1R5Y@
E2E-X2MY@
2 mm 10%
0 to 1.6 mm
E2E-X2Y@
E2E-X5MY@
5 mm 10%
0 to 4 mm
E2E-X5Y@
E2E-X10MY@ E2E-X10Y@
10 mm 10%
E2E-X18MY@
18 mm 10%
0 to 14 mm
Sensing distance
Set distance
1.5 mm 10%
0 to 1.2 mm
0 to 8 mm
Differential travel
Detectable object
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 19.)
Standard sensing
object
Iron,
8 × 8 × 1 mm
Iron,
Iron,
Iron,
54 × 54 × 1 mm
Iron, 12 × 12 × 1 mm
Iron, 30 × 30 × 1 mm
15 × 15 × 1 mm 18 × 18 × 1 mm
Response frequency
25 Hz
Power supply voltage
(operating voltage
range)*1
24 to 240 VAC (20 to 264 VAC), 50/60 Hz
1.7 mA max.
Leakage current
Load
5 to 100 mA
5 to 200 mA
5 to 300 mA
current *2
Control
output
Residual
voltage
Refer to Engineering Data on page 20.
Operation indicator (red)
Y1 Models: NO
Indicators
Operation mode
(with sensing object
approaching)
Refer to the timing charts under I/O Circuit Diagrams on page 23 for details.
Y2 Models: NC
Protection circuits
Surge suppressor
Ambient temperature Operating/Storage: −25 to 70°C
Operating/Storage: −40 to 85°C (with no icing or condensation)
range *1*2
(with no icing or condensation)
Ambient
Operating/storage: 35% to 95% (with no condensation)
10% max. of sensing distance
humidity range
Temperature
influence
15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C,
at 23°C in the temperature range
10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
of −25 to 70°C
Voltage influence
1% max. of sensing distance at rated voltage in the rated voltage 15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
Vibration resistance
4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2
Shock resistance
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Degree of protection
Connection method
Pre-wired Models (Standard cable length: 2 m) and Connector Models
Pre-
wired
Models
Approx. 60 g
Approx. 15 g
Approx. 70 g
Approx. 130 g
Approx. 40 g
Approx. 175 g
Approx. 90 g
Model
Weight
Connec-
tor
Models
Approx. 25 g
Case
Stainless steel (SUS303)
PBT
Nickel-plated brass
Sensing
surface
Materials
Clamp-
ing nuts
Nickel-plated brass
Toothed
washer
Zinc-plated iron
Accessories
Instruction manual
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least −25°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of
5 to 200 mA max.
14
E2E
E2E-X@T1 AC/DC 2-Wire Models
Size
M12
M18
M30
Shielded
Shielded
E2E-X7T1
Item
Model
E2E-X3T1
E2E-X10T1
Sensing distance
Set distance
3 mm 10%
0 to 2.4 mm
7 mm 10%
0 to 5.6 mm
10 mm 10%
0 to 8 mm
Differential travel
Detectable object
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.)
Standard sensing object
Iron, 12 × 12 × 1 mm
Iron, 18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
DC
AC
1 kHz
0.5 kHz
0.4 kHz
Response
frequency *1
25 Hz
Power supply voltage
24 to 240 VDC (20 to 264 VDC)
(operating voltage range) *2 48 to 240 VAC (40 to 264 VAC)
DC: 1 mA max.
Leakage current
AC: 2 mA max.
Load
current
5 to 100 mA
Control
output
Residual
voltage
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
Indicators
Operation indicator (red), Setting indicator (green)
Operation mode
(with sensing object
approaching)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.)
Protection circuits
Load short-circuit protection (20 to 40 VDC only), Surge suppressor
Ambient temperature range Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity range
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Case
Operating/Storage: 35% to 95% (with no condensation)
10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
1% max. of sensing distance at rated voltage in the rated voltage 15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m)
Approx. 80 g
Approx. 140 g
Approx. 190 g
Nickel-plated brass
Sensing
surface
PBT
Materials
Clamping
nuts
Nickel-plated brass
Toothed
washer
Zinc-plated iron
Accessories
Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. Power Supply Voltage Waveform:
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
15
E2E
E2E-X@E@/F@ DC 3-Wire Models
Size
M8
M12
M18
M30
Shielded
Shielded
E2E
-X1R5E@/F@
1.5 mm 10%
0 to 1.2 mm
Unshielded
Shielded
E2E
-X2E@/F@
Unshielded
Shielded
E2E
-X5E@/F@
Unshielded
Shielded
Unshielded
E2E
E2E
E2E
E2E-X10E@/
F@
E2E
Item
Model
-X2ME@/F@
2 mm 10%
0 to 1.6 mm
-X5ME@/F@
5 mm 10%
0 to 4 mm
-X10ME@/F@
10 mm 10%
0 to 8 mm
-X18ME@/F@
18 mm 10%
0 to 14 mm
Sensing distance
Set distance
Differential travel
Detectable object
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.)
Standard sensing
object
Iron,
Iron,
Iron,
Iron,
Iron, 12 × 12 × 1 mm
0.8 kHz 1.5 kHz
Iron, 30 × 30 × 1 mm
0.2 kHz 0.4 kHz
8 × 8 × 1 mm
15 ×15 × 1 mm 18 × 18 × 1 mm
54 × 54 × 1 mm
Response frequency
*1
2 kHz
0.4 kHz 0.6 kHz
0.1 kHz
Power supply voltage
(operating voltage
range) *2
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.
Current consumption 13 mA max.
Load
200 mA max.
current *2
Control
output
Residual
2 V max. (Load current: 200 mA, Cable length: 2 m)
voltage
Indicators
Operation indicator (red)
Operation mode
(with sensing object
approaching)
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.
Protection circuits
Load short-circuit protection, Surge suppressor, Reverse polarity protection
Ambient
temperature range *2
Operating/Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity
range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C
10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
1% max. of sensing distance at rated voltage in the rated voltage 15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
Vibration resistance
1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2
Shock resistance
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant
Connector Models : IEC 60529 IP67
Degree of protection
Connection method
Pre-wired Models (Standard cable length: 2 m) and Connector Models
Pre-
wired
Approx. 65 g
Approx. 15 g
Approx. 75 g
Approx. 150 g
Approx. 40 g
Approx. 195 g
Approx. 90 g
Models
Weight
Connec-
tor
Models
Approx. 25 g
Case
Stainless steel (SUS303)
PBT
Nickel-plated brass
Sensing
surface
Materials
Clamp-
ing nuts
Nickel-plated brass
Toothed
washer
Zinc-plated iron
Accessories
Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and make sure that the Sensor has a control output
of 100 mA maximum.
16
E2E
E2E-C@C/B@ and E2E-X1C/B@ DC 3-Wire Models
Size
Shielded
Model
3 dia.
4 dia.
M5
5.4 dia.
Shielded
Item
E2E-CR6C/B@
E2E-CR8C/B@
E2E-X1C/B@
E2E-C1C/B@
Sensing distance
Set distance
0.6 mm 15%
0.8 mm 15%
0 to 0.5 mm
1 mm 15%
0 to 0.7 mm
0 to 0.4 mm
Differential travel
Detectable object
15% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.)
Standard sensing ob-
ject
Iron, 3 × 3 × 1 mm
Iron, 5 × 5 × 1 mm
Response frequency * 2 kHz
3 kHz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 10 mA max.
17 mA max.
Load
current
Open-collector output,
80 mA max. (30 VDC max.)
Open-collector output, 100 mA max. (30 VDC max.)
Control
output
1 V max.
(Load current: 80 mA,
Cable length: 2 m)
Residual
voltage
2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators
Operation indicator (red)
Operation mode
(with sensing object
approaching)
C1/B1 Models: NO
C2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 22 for details.
Protection circuits
Reverse polarity protection, Surge suppressor
Ambient
temperature range
Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient humidity
range
Operating/Storage: 35% to 95% (with no condensation)
Temperature influ-
ence
15% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
5% max. of sensing distance at
rated voltage in the rated voltage
10% range
Voltage influence
2.5% max. of sensing distance at rated voltage in the rated voltage 15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
Vibration resistance
Shock resistance
500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection
Connection method
IEC 60529 IP66
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 60 g
Case
Stainless steel (SUS303)
Nickel-plated brass
Sensing
surface
Heat-resistant ABS
Materials
Clamping
nuts
Nickel-plated brass (E2E-X1C/B@ only)
Toothed
washer
Zinc-plated iron (E2E-X1C/B@ only)
Accessories
Instruction manual
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
17
E2E
Engineering Data (Typical)
Sensing Area
Shielded Models
E2E-X@D@/-X@T1
12
E2E-C@C@/-X@C@
E2E-C@B1/-X@B@
E2E-X@E@/-X@Y@/-X@F@
12
1.6
Y
E2E-X10
1.4
E2E-X10
X
10
8
10
1.2
1.0
0.8
0.6
0.4
Y
8
X
E2E-X1/E2E-C1
E2E-CR8
E2E-X7
6
6
E2E-X3
E2E-X5
E2E-X2
E2E-X2
Y
4
4
E2E-CR6
X
E2E
-X1R5
2
0
2
0.2
0
0
−20 −15 −10
−5
0
5
10
15
−15
−10
−5
0
5
10
−3.0
−2.0
−1.0
0
1.0
2.0
Distance Y (mm)
Distance Y (mm)
Distance Y (mm)
Unshielded Models
E2E-X@MD@
E2E-X@ME@/-X@MY@/-X@MF@
30
30
Y
X
25
20
15
25
20
E2E-X18M
E2E
-X20M
15
E2E
-X14M
E2E-X10M
Y
10
10
X
E2E-X5M
E2E
-X8M
E2E-X2M
5
5
E2E
-X4M
0
−30
0
−30
−20
−10
0
10
20
−20
−10
0
10
20
Distance Y (mm)
Distance Y (mm)
Influence of Sensing Object Size and Material
E2E-X2D@
E2E-X3D@/-X3T1
E2E-X7D@/-X7T1
3.0
d ×
d
4.0
8
d ×
d ×
d
t
= 1 mm
d
t = 1 mm
t = 1 mm
Iron
3.5
X
7
6
5
4
3
2
1
X
X
2.5
2.0
1.5
1.0
0.5
3.0
2.5
2.0
1.5
1.0
0.5
Iron
Iron
Stainless
steel
(SUS304)
Stainless
steel
(SUS304)
Stainless
steel
(SUS304)
Brass
Brass
Aluminum
Copper
Aluminum
Copper
Brass
Aluminum
Copper
0
5
10
15
20
25
0
5
10
15
20
25
30
35 40
0
10
20
30
40
50
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
E2E-X10D@/-X10T1
E2E-X4MD@
E2E-X8MD@
6
12
d ×
d
12
d ×
d
d ×
d
t = 1 mm
t = 1 mm
t = 1 mm
X
X
X
Iron
5
4
3
2
1
10
10
8
Iron
8
6
4
2
Iron
Stainless
steel
(SUS304)
6
Stainless
steel
(SUS304)
Stainless
steel
(SUS304)
Brass
Aluminum
Copper
4
Brass
Aluminum
Copper
Brass
Aluminum
Copper
2
0
10
20
30
40
50
60
70
0
10
20
30
40
50
60
70
0
10 15 20
30
40
50
60
70
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
18
E2E
E2E-X14MD@
E2E-X20MD@
E2E-X1R5E@/-X1R5Y@/-X1R5F@
25
25
2.5
d ×
d ×
d ×
d
d
d
t = 1 mm
t = 1 mm
X
t = 1 mm
X
X
Iron
20
15
10
5
20
15
10
5
2.0
Iron
1.5
1.0
0.5
Iron
Stainless
steel
(SUS304)
Stainless steel
(SUS304)
Stainless
steel
(SUS304)
Brass
Aluminum
Brass
Aluminum
Copper
Brass
Aluminum
Copper
0
10
20
30
40
50
60
70
0
10 20 30 40 50 60 70 80 90100
Side length of sensing object: d (mm)
0
5
10
15
20
25
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
E2E-X2E@/-X2Y@/-X2F@
E2E-X5E@/-X5Y@/-X5F@
E2E-X10E@/-X10Y@/-X10F@
7
12
2.5
d ×
d ×
d ×
d
d
d
t = 1 mm
t = 1 mm
t = 1 mm
Iron
6
5
4
3
2
1
X
X
X
Iron
10
2.0
Iron
Stainless steel
(SUS304)
8
Stainless steel (SUS304)
Stainless steel
(SUS304)
1.5
1.0
0.5
6
4
2
Brass
Brass
Brass
Aluminum
Aluminum
Aluminum
0
10
20
30
40
50
0
10
20
30
40
50
60
0
5
10
15
20
25
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
E2E-X2ME@/-X2MY@/-X2MF@
E2E-X5ME@/-X5MY@/-X5MF@
E2E-X10ME@/-X10MY@/-X10MF@
12
2.5
7
d ×
d ×
d ×
d
d
d
t = 1 mm
t = 1 mm
Iron
t = 1 mm
X
X
6
5
4
3
2
1
X
10
8
Iron
2.0
1.5
1.0
0.5
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Stainless steel (SUS304)
6
Brass
Aluminum
Brass
4
Brass
Copper
Aluminum
Aluminum
2
0
10
20
30
40
50
60
0
5
10
15
20
25
30
0
10
20
30
40
50
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
E2E-X18ME@/-X18MY@/-X18MF@
E2E-CR6@
E2E-CR8@
1.2
25
0.7
d ×
d ×
d
d
t = 1 mm
t = 1 mm
X
X
Iron
0.6
0.5
0.4
1.0
0.8
0.6
0.4
0.2
20
Iron
Stainless steel (SUS304)
Iron
15
Brass
Stainless steel (SUS304)
Aluminum
Stainless steel (SUS304)
Brass
0.3
0.2
0.1
10
Brass
d ×
d
Aluminum
Copper
t = 1 mm
X
5
0
Aluminum
0
5
10
15
20
25
30
20
40
60
80
100
0
5
10
15
20
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
19
E2E
E2E-X1@/-C1@
1.2
d ×
d
t = 1 mm
X
Iron
1.0
0.8
0.6
0.4
0.2
Stainless steel
(SUS304)
Brass
Aluminum
0
5
10
15
20
25
Side length of sensing object: d (mm)
Leakage Current
E2E-X@D@
E2E-X@Y@
E2E-X@T1
1.0
1.4
1.4
1.2
1.0
0.8
0.6
0.4
1.2
1.0
0.8
0.6
0.4
0.2
AC power
0.8
E2E-X10D1-N
0.6
E2E-X3D1-N
DC power
0.4
0.2
Protective
resistance
E2E-X2D1-N
mA
~
E2E-X7D1-N
V
AC
power
~
0.2
Proximity
Sensor (OFF)
0
5
10
15
20
25
30
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Power supply voltage (V)
Power supply voltage (V)
Power supply voltage (V)
Residual Output Voltage
E2E-X@D@
E2E-X@T1
5
6
200 VAC
4
100 VAC
5
4
3
2
E2E-X@D1-M1J-T
24 VDC
3
2
E2E-X@D@
1
0
1
3
5
10
30
50 100
1
3
5
10
30
50 100
Load current (mA)
Load current (mA)
E2E-X@Y@ at 24 VAC
E2E-X@Y@ at 100 VAC
E2E-X@Y@ at 200 VAC
30
120
240
Residual output voltage
100
Residual output voltage
200
25
20
15
10
ON
ON
80
160
Residual output voltage
V
~
V
~
ON
60
120
V
L
VL
V
200 VAC
~
100 VAC
A
A
~
~
40
20
0
80
40
0
VL
24 VAC
OFF
A
~
5
Residual
load voltage
Residual load
voltage
Residual load
voltage
OFF
300 500
Load current (mA)
OFF
0
1
3
5
10
30 50 100
300 500
1
3
5
10
30 50 100
1
3
5
10
30 50 100
300 500
Load current (mA)
Load current (mA)
20
E2E
I/O Circuit Diagrams
E2E-X@D@ DC 2-Wire Models
Operation
mode
Model
Timing Chart
Output circuit
Polarity: Yes
1
Load
+V
Brown
E2E-X@D1-N
Prox-
imity
Sensor
main
E2E-X@D1-M1G(J)
E2E-X@D1-(M1TGJ)-U
E2E-X@D1-M3G
Set position
Unstable
sensing
area
Non-sensing
area
circuit
Stable sensing area
Proximity Sensor
4
0 V
Blue
Sensing
object
Note: The load can be connected to either the
+V or 0 V side.
Without
self-
diagnostic
output:
NO
100 80
0
(%)
Rated
sensing
distance
Polarity: None
ON
Setting indicator
(green)
4
OFF
ON
Load
+V
(0 V)
Operation
indicator (red)
Prox-
imity
Sensor
main
circuit
OFF
ON
Control output
OFF
E2E-X@D1-M1J-T
3
0 V
(+V)
Note 1. The load can be connected to either the +V or
0 V side.
2. The E2E-X@D1-M1J-T has no polarity.
Therefore, terminals 3 and 4 have no polarity.
Non-sensing
area
Sensing area
Proximity Sensor
1
Load
Brown
Sensing
object
+V
Prox-
imity
Sensor
main
circuit
2
Without
E2E-X@D2-N
self-
100
0
(%)
E2E-X@D2-M1G
diagnostic
E2E-X@D2-(M1TGJ)-U
output:
Rated
E2E-X@D2-M3G
NC
sensing
distance
0 V
Blue
ON
OFF
Note: The load can be connected to either the +V
or 0 V side.
Operation
indicator (red)
ON
Control output
OFF
Unstable
Non-sensing sensing
Set position
area
area
Stable sensing area
Proximity Sensor
Sensing
object
Brown (4)
Load
+V
100 80
0
(%)
Load
Rated
sensing
distance
Prox-
+V
Orange (2)
imity
ON
With self-
diagnostic E2E-X@D1S
Sensor
main
circuit
(diagnostic
output)
OFF Setting indicator
(green)
ON
output:
NO
E2E-X@D1S-M1
Blue (3)
OFF Operation
indicator (red)
ON
0
OFF
ON
Control output
Note: Connect both the loads to the +V side of
the control output and diagnostic output.
Diagnostic output*
OFF
* The diagnostic output is ON when there is a coil
burnout or the sensing object is located in the
unstable sensing area for 0.3 s or longer.
21
E2E
DC 3-Wire Models
Output
specifica-
tions
Operation
mode
Model
Timing Chart
Output circuit
Sensing
object
Present
Not present
ON
1
Operation
indicator (red)
+V
Brown
100 Ω
OFF
ON
Control output
(between brown
and black leads)
NO
Load
Constant
current*
Proximity
Sensor
main
OFF
High
Low
4
2
Output voltage
(between black
and blue leads)
Black
circuit
Tr
E2E-X@E@
NPN output E2E-X@E@-M1
E2E-X@E@-M3
3
0 V
Present
Sensing object
Blue
Not present
*Constant current output is 1.5 to 3 mA.
Note: For Connector Models, the
Operation indicator
ON
OFF
ON
(red)
NC
connection between pins 1, 4 and 3
uses an NO contact, and the
connection between pins 1, 2 and 3
uses an NC contact.
Control output
(between brown and
black leads)
OFF
High
Low
Output voltage
(between black and
blue leads)
Present
Sensing object
1
Not present
Brown
Operation indicator
(red)
+V
ON
OFF
ON
NO
Control output
(Between blue and
black leads)
Tr
Proximity
Sensor
main
*
2
4
OFF
High
Low
Output voltage
(between brown
and black leads)
Black
circuit
E2E-X@F@
PNP output E2E-X@F@-M1
E2E-X@F@-M3
Load
3
100 Ω
Blue
0 V
Present
Sensing object
Not present
Operation indicator
(red)
*When a transistor is connected
Note: For Connector Models, the
ON
OFF
ON
Control output
(Between blue and
black leads)
NC
connection between pins 1, 4 and 3
uses an NO contact, and the
connection between pins 1, 2 and 3
uses an NC contact.
OFF
High
Low
Output voltage
(between brown
and black leads)
Present
Not present
ON
Sensing
object
Brown
+V
Operation
NO
NC
NO
100 Ω *
indicator (red)
OFF
ON
Load
Control output
Proximity
Sensor
main
NPN open-
collector
output
OFF
Black
E2E-C/X@C@
circuit
Present
Not present
ON
Sensing
object
Blue
0 V
Operation
indicator (red)
OFF
ON
*The E2E-CR6@ does not have 100-Ω resistance.
Control
output
OFF
Present
Not present
ON
Sensing
object
Brown
+V
Operation
indicator (red)
OFF
ON
Proximity
Sensor
main
Control output
PNP open-
collector
output
OFF
Black
E2E-C/X@B@
circuit
Present
Not present
ON
Load
Sensing
object
100 Ω *
Blue
0 V
Operation
NC
indicator (red)
OFF
ON
*The E2E-CR6@ does not have 100-Ω resistance.
Control output
OFF
22
E2E
AC 2-Wire Models
Operation
Model
Timing Chart
Output circuit
mode
Present
Not present
ON
Sensing
object
Brown 3 (or 1)
Load
Operation
NO
OFF
indicator (red)
Proximity
Sensor
main
Operate
Control output
Reset
circuit
E2E-X@Y@
E2E-X@Y@-M1
Blue 4 (or 2)
Present
Not present
ON
Sensing
object
Operation
Note: For Connector Models, the connection
between pins 3 and 4 uses an NO
contact, and the connection between
pins 1 and 2 uses an NC contact.
NC
indicator (red)
OFF
Operate
Reset
Control
output
AC/DC 2-Wire Models
Operation
Model
Timing Chart
Output circuit
mode
Unstable
sensing
area
Brown
Load
Set position
Non-sensing
area
Stable sensing area
Proximity Sensor
Proximity
Sensor
main
Power
supply
Sensing
object
24 to 240 VDC
48 to 240 VAC
circuit
100 80
0
(%)
NO
E2E-X@T1
Blue
Rated
sensing
distance
ON
Setting indicator
(green)
OFF
ON
Note: The load can be connected to either the +V or
0 V side.
Operation
indicator (red)
OFF
ON
There is no need to be concerned about the
polarity (brown/blue) of the Proximity Sensor.
Control output
OFF
23
E2E
Sensor I/O Connectors
Model for Connectors and Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.
[Refer to Dimensions for the XS2, XS3, and XS5.]
Connector
Cable length 2m
Applicable
connector
code
ApplicableProximity Connection
Cable length 5m
Sensor model
number
diagram
No. *2
Screw
Appearance *1
CablConnector
model number
CablConnector
model number
Straight
L-shape
Straight
L-shape
XS2F-D421-DA0-A
XS2F-D422-DA0-A
XS2F-D421-DC0-A
XS2F-D422-DC0-A
XS2F-D421-GA0-A
XS2F-D422-GA0-A
XS2F-D421-GC0-A
XS2F-D422-GC0-A
A
B
E2E-X@D1-M1G(J)
1
E2E-X@E1-M1
E2E-X@F1-M1
10
E2E-X@D1-M1J-T
E2E-X@D1-M1
E2E-X@D1-M1J-T
E2E-X@D1-M1
E2E-X@D2-M1G(J)
E2E-X@D2-M1J-T
E2E-X@D2-M1
E2E-X@D1S-M1
E2E-X@E2-M1
E2E-X@F2-M1
E2E-X@D2-M1G(J)
E2E-X@D2-M1J-T
E2E-X@D2-M1
3
2
3
2
6
8
7
5
Straight
L-shape
XS2F-D421-DD0
XS2F-D422-DD0
XS2F-D421-GD0
XS2F-D422-GD0
C
Straight
L-shape
XS2F-D421-D80-A
XS2F-D422-D80-A
XS2F-D421-G80-A
XS2F-D422-G80-A
11
D
E
6
8
7
5
M12
E2E-X@D1S-M1
E2E-X@E2-M1
E2E-X@F2-M1
11
14
Straight
L-shape
Straight
XS2F-A421-DB0-A
XS2F-A422-DB0-A
XS2F-A421-D90-A
XS2F-A421-GB0-A
XS2F-A422-GB0-A
XS2F-A421-G90-A
E2E-X@Y1-M1
F
E2E-X@Y2-M1
15
16
Smartclick Connector,
Straight
G
XS5F-D421-D80-A
XS5F-D421-G80-A
E2E-X@D1-M1TGJ
Smartclick Connector,
Straight
Oil-resistant
Reinforced Cables
E2E-X@D1-M1TGJ-U
E2E-X@D2-M1TGJ-U
17
18
H
XS5F-D421-D80-P
XS5F-D421-G80-P
E2E-X@D1-M3G
E2E-X@D2-M3G
4
9
E2E-X@E1-M3
E2E-X@F1-M3
E2E-X@E2-M3
E2E-X@F2-M3
E2E-X@D1-M3G
E2E-X@D2-M3G
E2E-X@E1-M3
E2E-X@F1-M3
Straight
L-shape
XS3F-M421-402-A
XS3F-M422-402-A
XS3F-M421-405-A
XS3F-M422-405-A
12
13
I
M8
4
9
12
13
E2E-X@E2-M3
E2E-X@F2-M3
Note: Refer to Introduction to Sensor I/O Connectors for details and for information on Cable length and Robotics Cables.
*1. Images of straight and L-shaped connectors.
M12 Straight
M8 Straight
M8 L-shape
M12 L-shape
*2. Refer to Connection Diagrams on page 25 for information on Proximity Sensor and I/O Connector connections.
24
E2E
Connections for Sensor I/O Connectors
Proximity Sensor
Connection
diagram No.
Sensor I/O Connector
Connections
Operation
mode
model number
Type
Model
1: Straight
2: L-shape
E2E
XS2F
1
2
3
4
1
2
3
4
DC 2-wire
Brown (+)
1
2
3
4
5
6
7
8
9
E2E-X@D1-M1G(J) XS2F-D42@-@A0-A
(IEC pin wiring)
D: 2-m cable
G: 5-m cable
Blue (−)
1: Straight
2: L-shape
E2E
XS2F
DC 2-wire
(previous pin
wiring)
1
2
3
4
1
2
3
4
E2E-X@D1-M1
XS2F-D42@-@D0
Blue (−)
Brown (+)
D: 2-m cable
G: 5-m cable
1: Straight
2: L-shape
E2E
XS2F
1
2
3
4
1
2
3
4
DC 2-wire
(no polarity)
NO
E2E-X@D1-M1J-T
E2E-X@D1-M3G
E2E-X@D1S-M1
XS2F-D42@-@D0
Blue (+) (−)
Brown (−) (+)
D: 2-m cable
G: 5-m cable
1: Straight
2: L-shape
E2E
XS3F
*
1
1
2
3
4
Brown (+)
DC 2-wire
(M8 connector)
XS3F-M42@-40@-A
2
3
4
White (not connected)
Blue (not connected)
Black (−)
2: 2-m cable
5: 5-m cable
1: Straight
2: L-shape
E2E
XS2F
*
DC 2-wire
(diagnostic
type)
1
2
3
4
1
2
3
4
Brown (not connected)
White (diagnostic output) (+)
Blue (0 V)
XS2F-D42@-@80-A
Black (control output) (+)
D: 2-m cable
G: 5-m cable
1: Straight
2: L-shape
E2E
E2E
E2E
E2E
XS2F
*
*
1
2
3
4
1
2
3
4
Brown (+)
DC 2-wire
(IEC pin wiring)
E2E-X@D2-M1G(J) XS2F-D42@-@80-A
White (−)
Blue (not connected)
Black (not connected)
D: 2-m cable
G: 5-m cable
1: Straight
2: L-shape
XS2F
DC 2-wire
(previous pin
wiring)
1
2
3
4
1
2
3
4
Brown (not connected)
White (+)
Blue (−)
Black (not connected)
E2E-X@D2-M1
XS2F-D42@-@80-A
D: 2-m cable
G: 5-m cable
NC
1: Straight
2: L-shape
XS2F
*
1
1
2
3
4
Brown (+)(−)
White (−)(+)
Blue (not connected)
Black (not connected)
DC 2-wire
(no polarity)
E2E-X@D2-M1J-T
E2E-X@D2-M3G
XS2F-D42@-@80-A
2
3
4
D: 2-m cable
G: 5-m cable
1: Straight
2: L-shape
XS3F
*
1
1
2
3
4
Brown (+)
White (−)
Blue (not connected)
Black (not connected)
DC 2-wire
(M8 connector)
2
3
4
XS3F-M42@-40@-A
2: 2-m cable
5: 5-m cable
* Different from Proximity Sensor wire colors.
25
E2E
Proximity Sensor
Connection
diagram No.
Sensor I/O Connector
model number
Connections
Operation
mode
Type
Model
1: Straight
2: L-shape
E2E
XS2F
1
2
3
4
1
2
3
4
Brown (+V)
10
11
12
13
14
15
16
17
18
NO
NC
NO
NC
NO
NC
E2E-X@E/F1-M1
XS2F-D42@-@C0-A
Blue (0 V)
Black (output)
D: 2-m cable
G: 5-m cable
DC 3-wire
1: Straight
2: L-shape
E2E
XS3F
1
1
2
3
4
Brown (+V)
White (not connected)
Blue (0 V)
E2E-X@E2/F2-M1 XS2F-D42@-@80-A
2
3
4
D: 2-m cable
G: 5-m cable
Black (output)
1: Straight
2: L-shape
E2E
XS3F
1
1
2
3
4
Brown (+V)
White (not connected)
Blue (0 V)
2
3
4
E2E-X@E1/F1-M3
E2E-X@E2/F2-M3
E2E-X@Y1-M1
XS3F-M42@-40@-A
2: 2-m cable
5: 5-m cable
Black (output)
DC 3-wire
(M8 connector)
1: Straight
2: L-shape
E2E
E2E
E2E
XS3F
1
1
2
3
4
Brown (+V)
White (output)
Blue (0 V)
XS3F-M42@-40@-A
2
3
4
2: 2-m cable
5: 5-m cable
Black (not connected)
1: Straight
2: L-shape
XS2F
1
1
2
3
4
XS2F-A42@-@B0-A
2
3
4
Brown
Blue
D: 2-m cable
G: 5-m cable
AC 2-wire
XS2F
*
XS2F-A421-@90-A
1
2
3
4
1
2
3
4
Brown
White
E2E-X@Y2-M1
D: 2-m cable
G: 5-m cable
Blue (not connected)
Black (not connected)
E2E
E2E
E2E
XS5F
XS5F-D421-@80-A
1
1
2
3
4
Brown (+)
E2E-X@D1-M1TGJ
2
3
4
White (not connected)
Blue (not connected)
Black (−)
D: 2-m cable
G: 5-m cable
NO
XS5F
XS5F-D421-@80-P
DC 2-wire
(Smartclick
connector)
1
2
3
4
1
2
3
4
Brown (+)
E2E-X@D1-
White (not connected)
Blue (not connected)
Black (−)
M1TGJ-U
D: 2-m cable
G: 5-m cable
XS5F
XS5F-D421-@80-P
1
2
3
4
1
2
3
4
Brown (+)
White (−)
Blue (not connected)
Black (not connected)
E2E-X@D2-
NC
M1TGJ-U
D: 2-m cable
G: 5-m cable
* Different from Proximity Sensor wire colors.
Refer to Introduction to Sensor I/O Connectors for details.
26
E2E
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
CAUTION
• Do not short the load. Explosion or burning may
result.
• Do not supply power to the Sensor with no load,
otherwise Sensor may be damaged.
Applicable Models
E2E-CR6@
E2E-CR8@
E2E-X1@
E2E-C1@
Relationship between Sizes and
Models
Model
Model
E2E-CR6C/B
E2E-CR8C@
E2E-CR8B@
E2E-X1C@
Precautions for Correct Use
Do not use this product under ambient conditions that exceed the
ratings.
3 dia.
4 dia.
● Design
Shielded
M5
Influence of Surrounding Metal
E2E-X1B@
E2E-C1C@
E2E-C1B@
E2E-X2D@
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
5.4
dia.
E2E-X1R5E@
E2E-X1R5F@
E2E-X1R5Y@
E2E-X4MD@
E2E-X2ME@
E2E-X2MF@
E2E-X2MY@
E2E-X3D@
E2E-X2E@
E2E-X2F@
E2E-X2Y@
E2E-X3T1
Shielded
l
M8
n
d dia.
m
D
m
Influence of Surrounding Metal
Model
l
Unshielded
(Unit: mm)
Item
l
M8
M12
M18
M30
0
0
Shielded
d
8
12
18
30
Shielded
D
m
n
M12
4.5
12
12
24
12
8
8
18
15
40
15
20
40
20
27
22
70
22
40
70
40
45
30
90
30
70
90
DC 2-Wire Models
E2E-X@D@
E2E-X8MD@
E2E-X5ME@
E2E-X5MF@
E2E-X5MY@
E2E-X7D@
E2E-X5E@
E2E-X5F@
E2E-X5Y@
E2E-X7T1
l
AC/DC 2-Wire Models
Unshielded
Shielded
E2E-X@T1
d
Unshielded
D
m
n
24
l
0
0
d
8
12
18
30
M18
Shielded
DC 3-Wire Models
E2E-X@E@
D
m
n
E2E-X14MD@
E2E-X10ME@
E2E-X10MF@
E2E-X10MY@
E2E-X10D@
E2E-X10E@
E2E-X10F@
E2E-X10Y@
E2E-X10T1
E2E-X20MD@
E2E-X18ME@
E2E-X18MF@
E2E-X18MY@
4.5
12
6
8
18
15
40
15
20
36
20
27
22
55
22
40
54
40
45
30
90
30
70
90
E2E-X@F@
Unshielded
Shielded
l
AC 2-Wire Models
E2E-X@Y@
d
24
6
Unshielded
D
m
n
8
24
Model
Item
3 dia.
4 dia.
M5
5.4 dia.
M30
l
0
0
d
3
2
4
5
5.4
DC 3-Wire Models
Unshielded
E2E-X@C/B@
E2E-C@C/B@
Shielded
D
m
n
2.4
3
8
6
27
E2E
Mutual Interference
Mutual Interference
(Unit: mm)
When installing Sensors face-to-face or
side-by-side, ensure that the minimum
distances given in the following table are
maintained.
Model
Item
A
M8
20
15
80
60
20
15
80
60
M12
M18
M30
30 (20)
20 (12)
120 (60)
100 (50)
30 (20)
20 (12)
120 (60)
100 (50)
50 (30)
100 (50)
70 (35)
DC 2-Wire Models
Shielded
E2E-X@D@
B
35 (18)
A
200 (100)
110 (60)
50 (30)
300 (100)
200 (100)
100 (50)
70 (35)
AC/DC 2-Wire Models
Unshielded
Shielded
E2E-X@T1
B
A
DC 3-Wire Models
E2E-X@E@/X@F@
B
35 (18)
A
A
200 (100)
110 (60)
300 (100)
200 (100)
AC 2-Wire Models
Unshielded
E2E-X@Y@
B
Model
Item
A
3 dia.
4 dia.
M5
5.4 dia.
B
DC 3-Wire Models
E2E-X@C/B@
20
15
Shielded
B
E2E-C@C/B@
Note: Values in parentheses apply to Sensors operating at different frequencies.
Loads with Large Surge Currents (E2E-X@T@)
If a load with a large surge current is connected, such as a relay, lamp, or motor, the surge current may cause the load short-circuit protection
circuit to operate, resulting in operating errors.
● Mounting
Tightening Force
Do not tighten the nut with excessive force.
A washer must be used with the nut.
Refer to the following to mount the E2E-CR6, E2E-CR8 and E2E-C1
Unthreaded Cylindrical Models.
E2E-CR6
E2E-CR8, E2E-C1 8 to 21 mm
9 to 21 mm
Shielded Models
Unshielded Models
Dimpled end of
set screw (M3)
(No screws are provided
with the E2E-CR8 or
E2E-C1.)
Part B Part A
Part B Part A
Note: 1. The allowable tightening strength depends on the distance from the
edge of the head, as shown in the following table. (A is the distance
from the edge of the head. B includes the nut on the head side. If the
edge of the nut is in part A, the tightening torque for part A applies
instead.)
When using a set screw, tighten it to a torque of 0.2 N·m max.
(E2E-C1: 0.4 N·m max.)
2. The following strengths assume washers are being used.
Part A
Part B
Model
Dimension
Torque
Torque
M5
M8
1 N·m
Shielded
9
3
9 N·m
12 N·m
Unshielded
M12
M18
M30
30 N·m
70 N·m
180 N·m
Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller)
Required Conditions
Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following
conditions. (The meanings of the symbols are given at the right.)
1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following.
VON ≤ VCC− VR
VON:ON voltage of PLC (14.4 V)
ION: ON current of PLC (typically 7 mA)
IOFF: OFF current of PLC (1.3 mA)
RIN: Input impedance of PLC (3 kΩ)
VPC: Internal residual voltage of PLC (4 V)
VR: Output residual voltage of Proximity Sensor
(3 V)
Ileak: Leakage current of Proximity Sensor
(0.8 mA)
IOUT Control output of Proximity Sensor (3 to
2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following.
IOFF ≥ Ileak
(If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.)
3. The ON current of the PLC and the control output of the Proximity Sensor must satisfy the following.
IOUT (min.) ≤ ION ≤ IOUT (max.)
The ON current of the PLC will vary, however, with the power supply voltage and the input impedance, as
shown in the following equation.
ION = (VCC − VR − VPC)/RIN
100 mA)
VCC:Power supply voltage (PLC: 20.4 to 26.4 V)
Values in parentheses apply to the following PLC
model and Proximity Sensor model.
Example
In this example, the above conditions are checked when the PLC Unit is the C200H-ID212, the Proximity
Sensor is the E2E-X7D1-N, and the power supply voltage is 24 V.
1. VON (14.4 V) ≤ VCc (20.4 V) − VR (3 V) = 17.4 V:OK
PLC:
C200H-ID212
Sensor: E2E-X7D1-N
2. IOFF (1.3 mA) ≥ Ileak (0.8 mA):
OK
3. ION = [VCC (20.4 V) − VR (3 V) − VPLC (4 V)]/RIN (3 kΩ) = Approx. 4.5 mA
Therefore, IOUT (min.) (3 mA) ≤ ION (4.5 mA):
Connection is thus possible.
OK
28
E2E
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Main Units
Model Number-Dimensions Drawing Number Lookup Table
Model
Shielded
DC 2-Wire Models
Model
DC 3-Wire Models
Model
AC 2-Wire Models
Model
AC/DC 2-Wire Models
Model
No.
No.
1
No.
Model
No.
3 dia.
4 dia.
M5
E2E-CR6@
E2E-CR8@
2
---
---
E2E-X1@
4
---
5.4 dia.
M8
E2E-C1@
3
Shielded
E2E-X2D@
5
9
E2E-X1R5E@/F@
E2E-X2E@/F@
5
E2E-X1R5Y@
E2E-X2Y@
7
M12
M18
M30
M8
E2E-X3D@
9
11 E2E-X3T1
13
14
16
Pre-wired Models
E2E-X7D@
14 E2E-X5E@/F@
16 E2E-X10E@/F@
14 E2E-X5Y@
16 E2E-X10Y@
14 E2E-X7T1
E2E-X10D@
16 E2E-X10T1
E2E-X4MD@
6
E2E-X2ME@/F@
6
E2E-X2MY@
8
M12
M18
M30
M8
E2E-X8MD@
10 E2E-X5ME@/F@
15 E2E-X10ME@/F@
17 E2E-X18ME@/F@
18 E2E-X1R5E/F@-M1
20 E2E-X2E/F@-M1
24 E2E-X5E/F@-M1
26 E2E-X10E/F@-M1
19 E2E-X2ME/F@-M1
21 E2E-X5ME/F@-M1
25 E2E-X10ME/F@-M1
27 E2E-X18ME/F@-M1
28 E2E-X1R5E/F@-M3
10 E2E-X5MY@
15 E2E-X10MY@
17 E2E-X18MY@
12
15
17
Unshielded
Shielded
---
---
E2E-X14MD@
E2E-X20MD@
E2E-X2D@-M1(G)
E2E-X3D@-M1(G)
E2E-X7D@-M1(G)
E2E-X10D@-M1(G)
E2E-X4MD@-M1(G)
E2E-X8MD@-M1(G)
E2E-X14MD@-M1(G)
E2E-X20MD@-M1(G)
E2E-X2D@-M3G
18
---
M12
M18
M30
M8
20 E2E-X2Y@-M1
24 E2E-X5Y@-M1
26 E2E-X10Y@-M1
22
24
26
Connector
Models
(M12)
19
---
M12
M18
M30
21 E2E-X5MY@-M1
25 E2E-X10MY@-M1
27 E2E-X18MY@-M1
28
23
25
27
Unshielded
---
---
---
Connector
Models
(M8)
Shielded
M8
---
Unshielded
E2E-X4MD@-M3G
29 E2E-X2ME/F@-M3
29
M8
E2E-X2D@-M1(T)GJ(-U) 30
E2E-X3D@-M1(T)GJ(-U) 31
E2E-X7D@-M1(T)GJ(-U) 33
E2E-X10D@-M1(T)GJ(-U) 35
M12
M18
M30
M12
Shielded
---
---
Pre-wired
Connector
Models
E2E-X8MD1-M1(T)GJ
E2E-X14MD1-M1(T)GJ
E2E-X20MD1-M1(T)GJ
E2E-X3D1-M1J-T
32
34
36
31
33
35
Unshielded M18
M30
---
---
---
---
---
---
Pre-wired
Connector
Models
M12
Shielded M18
M30
E2E-X7D@-M1J-T
E2E-X10D@-M1J-T
(no polarity)
Note 1. Two clamping nuts and one toothed washer are provided with M8 to M30 Models.
2. The model numbers of M8 to M30 Pre-wired Models are laser-marked on the milled section and cable section. This does not apply, however, to models that
end in -U.
Pre-wired Models (Shielded)
Diagram 1 E2E-CR6B@/CR6C@
Diagram 3 E2E-C1B@/C1C@
25
0.1
27
3
dia.
5.4 dia.
17.5
17
*
*
Operation indicator (red)
Operation indicator (red)
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
*2.4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.08 mm2, Insulator diameter: 0.7 mm)
Diagram 2 E2E-CR8B@/CR8C@
Mounting Hole Dimensions
4 dia.
25
17.5
*
Operation indicator (red)
F
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
Dimension
3 dia.
4 dia.
5.4 dia.
F (mm)
3.3+0.3 dia. 4.2+0.5 dia. 5.7+0.5 dia.
0
0
0
29
E2E
Pre-wired Models
(Shielded)
Mounting Hole Dimensions
Dimension
F (mm)
M5
M8
M12
5.5+0.5 dia. 8.5+0.5 dia. 12.5+0.5 dia.
0
0
0
F
Diagram 4 E2E-X1B@/X1C@
Pre-wired Models (Unshielded)
25
10 dia.
17.5
8
15
*
Operation indicator (red)
Two clamping nuts
Two toothed washers
4
M5 × 0.5
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
Diagram 5 E2E-X2D@
E2E-X1R5E@/F@
Diagram 6 E2E-X4MD@
E2E-X2ME@/F@
7
30
30
7
15 dia.
15 dia.
13
26
26
13
3
8
6
3
8
6.1 dia.
M8 × 1
*1
Indicators *2
Two clamping nuts
Toothed washer
*1
M8 × 1
Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3
mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
The cable can be extended up to 200 m (separate metal conduit).
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
Diagram 8 E2E-X2MY@
Diagram 7 E2E-X1R5Y@
7
40
36
40
7
15 dia.
36
15 dia.
13
3
8
13
8
6
3
6.1 dia.
M8 × 1
*
*
Operation indicator (red)
Two clamping nuts
Operation indicator (red)
Two clamping nuts
M8 × 1
4-dia. vinyl-insulated round cable with 2 conductors
4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Toothed
washer
Toothed
washer
(Conductor cross section: 0.3 mm2, Insulator
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Diagram 10 E2E-X8MD@
E2E-X5ME@/F@
Diagram 9 E2E-X3D@
E2E-X2E@/F@
38
33
9
38
9
21 dia.
21 dia.
33
17
17
7
4
10
4
10
9 dia.
*1
*1
Indicators * 2
Two clamping nuts
Toothed washer
Indicators *2
Two clamping nuts
Toothed washer
M12 × 1
M12 × 1
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
,
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2 Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3
mm), Standard length: 2 m
Robotics Cable Models:
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the
diagnostic output.
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the
diagnostic output.
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
30
E2E
Diagram 12 E2E-X5MY@
Diagram 11 E2E-X2Y@
43
9
43
9
21 dia.
17
21 dia.
17
38
38
7
4
10
4
10
9 dia.
*
*
Operation indicator (red)
Two clamping nuts
Operation indicator (red)
Two clamping nuts
Toothed
washer
M12 × 1
M12 × 1
4-dia. vinyl-insulated round cable with 2
4-dia. vinyl-insulated round cable with 2
Toothed
washer
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Pre-wired Models (Shielded)
Mounting Hole Dimensions
Dimension
F (mm)
M8
M12
M18
M30
8.5+0.5 dia. 12.5+0.5 dia. 18.5+0.5 dia. 30.5+0.5 dia.
0 0 0 0
F
Diagram 13 E2E-X3T1
Pre-wired Models (Unshielded)
60
9
21 dia.
17
55
4
10
*1
Indicators *2
M12 × 1
Two clamping nuts
*1 4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Toothed
washer
*2 Operation indicator (red), Setting indicator (green)
Diagram 14 E2E-X7D@/E2E-X5E@/F@
E2E-X5Y@/E2E-X7T1
Diagram 15 E2E-X14MD@/E2E-X10ME@/F@
E2E-X10MY@
43
38
43
38
12
12
29 dia.
24
29 dia.
24
4
10
4
10
10
14.8 dia.
*1
*1
Indicators *2
*1
Indicators *2
M18 × 1
M18 × 1
Two clamping nuts
Toothed washer
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
Models with Highly Oil-resistant Cables:
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.5
mm2, Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and
up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
31
E2E
Diagram 16 E2E-X10D@/E2E-X10E@/F@
E2E-X10Y@/E2E-X10T1
Diagram 17 E2E-X20MD@/E2E-X18ME@/F@
E2E-X18MY@
48
43
48
43
12
12
42 dia.
36
42 dia.
36
5
10
13
5
10
26.8 dia.
*1
*1
Indicators *2
Indicators *2
M30 × 1.5
Two clamping nuts
Toothed washer
M30 × 1.5
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
Models with Highly Oil-resistant:
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section:
0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
M8 Connector Models
(Shielded)
M8 Connector Models
(Unshielded)
Diagram 28 E2E-X2D@-M3G/E2E-X1R5E@-M3/X1RF@-M3
Diagram 29 E2E-X4MD@-M3G/E2E-X2ME@-M3/X2MF@-M3
39
31
39
31
15 dia.
13
15 dia.
13
26
26
8
3
M8 × 1
M8 × 1
* D Models:
8
6
3
* D Models:
Operation indicator (red),
Setting indicator (green)
Operation indicator (red),
Setting indicator (green)
6.1 dia.
M8 × 1
D2/E/F Models: Operation indicator (red)
D2/E/F Models: Operation indicator (red)
M8 × 1
Indicators*
Two clamping nuts
Toothed washer
Indicators*
Two clamping nuts
Toothed washer
M12 Connector Models
(Shielded)
M12 Connector Models
(Unshielded)
Diagram 19 E2E-X4MD@-M1(G)
E2E-X2ME@-M1/E2E-X2MF@-M1
Diagram 18 E2E-X2D@-M1(G)
E2E-X1R5E@-M1/E2E-X1R5F@-M1
43
43
30
26
30
26
15 dia.
13
15 dia.
13
M12 × 1
M12 × 1
8
6
3
8
3
6.1 dia.
M8 × 1
Indicators*
Two clamping nuts
Toothed washer
Indicators*
Two clamping nuts
Toothed washer
M8 × 1
* D1 Models:
Operation indicator (red),
Setting indicator (green)
* D1 Models:
Operation indicator (red),
Setting indicator (green)
D2/E/F Models: Operation indicator (red)
D2/E/F Models: Operation indicator (red)
32
E2E
Diagram 20 E2E-X3D@-M1(G)
E2E-X2E@-M1/E2E-X2F@-M1
Diagram 21 E2E-X8MD@-M1(G)
E2E-X5ME@-M1/E2E-X5MF@-M1
48
48
21 dia.
17
21 dia.
17
33
33
4
10
M12 × 1
4
10
7
M12 × 1
9 dia.
Indicators *
Two clamping nuts
Toothed washer
Indicators*
Two clamping nuts
Toothed washer
M12 × 1
M12 × 1
* D1 Models:
Operation indicator (red),
Setting indicator (green)
* D1 Models:
D2/E/F Models:Operation indicator (red)
Operation indicator (red), Setting indicator (green)
D2/E/F Models:Operation indicator (red)
Diagram 22 E2E-X2Y@-M1
Diagram 23 E2E-X5MY@-M1
53
53
21 dia.
17
21 dia.
38
38
M12 × 1
4
10
7
4
10
17
M12 × 1
9 dia.
Operation indicator (red)
Two clamping nuts
Operation indicator (red)
Two clamping nuts
Toothed washer
M12 × 1
M12 × 1
Toothed washer
Diagram 24 E2E-X7D@-M1(G)/E2E-X5E@-M1/X5F@-M1
E2E-X5Y@-M1
Diagram 25 E2E-X14MD@-M1(G)/E2E-X10ME@-M1
X10MF@-M1
E2E-X10MY@-M1
53
53
29 dia.
38
38
29 dia.
24
4
10
24
4
10
M12 × 1
10
M12 × 1
14.8 dia.
Indicators*
M18 × 1
Indicators*
Two clamping nuts
Toothed washer
M18 × 1
Two clamping nuts
Toothed washer
* D1 Models:
Operation indicator (red), Setting indicator (green)
D2/E/Y Models: Operation indicator (red)
* D1 Models:
Operation indicator (red), Setting indicator (green)
D2/E/Y Models: Operation indicator (red)
Diagram 27 E2E-X20MD@-M1(G)/E2E-X18ME@-M1/
X18MF@-M1
Diagram 26 E2E-X10D@-M1(G)/E2E-X10E@-M1/X10F@-M1
E2E-X10Y@-M1
E2E-X18MY@-M1
58
42 dia.
36
58
43
42 dia.
43
5
10
13
5
10
36
26.8 dia.
M12 × 1
Indicators*
M12 × 1
Indicators*
M30 × 1.5
Two clamping nuts
Toothed washer
M30 × 1.5
Two clamping nuts
Toothed washer
Operation indicator (red), Setting indicator (green)
* D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/Y Models: Operation indicator (red)
* D1 Models:
D2/E/Y Models: Operation indicator (red)
Mounting Hole Dimensions
Dimensions
F (mm)
M8
M12
M18
M30
8.5+0.5 dia. 12.5+0.5 dia. 18.5+0.5 dia. 30.5+0.5 dia.
0
0
0
0
F
33
E2E
Pre-wired Connector Models (Shielded)
Mounting Hole Dimensions
F
Dimension
M12
M18
M30
F (mm)
12.5+0.5 dia. 18.5+0.5 dia. 30.5+0.5 dia.
0
0
0
Diagram 30 E2E-X2D@-M1TGJ-U *3
30
26
7
15 dia.
13
E2E-X2D1-M1TGJ
8
3
*1
Indicators *2
Two clamping nuts
M8 × 1
M12 × 1
*1. No U suffix: 4-dia. Vinyl-insulated round cable
U suffix: 4-dia. Polyurethane insulated round cable,
Standard length: 300 mm
Toothed washer
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
Diagram 31 E2E-X3D@-M1GJ
E2E-X3D1-M1J-T
38
33
9
21 dia.
17
4
10
E2E-X3D@-M1TGJ-U *3
E2E-X3D1-M1TGJ
*1
Indicators *2
M12 × 1
M12 × 1
Two clamping nuts *1. No U suffix: 4-dia. Vinyl-insulated round cable
U suffix: 4-dia. Polyurethane insulated round cable,
Standard length: 300 mm
Toothed washer
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
43
38
12
Diagram 33 E2E-X7D@-M1GJ
E2E-X7D@-M1J-T
29 dia.
24
4
10
E2E-X7D@-M1TGJ-U *3
E2E-X7D1-M1TGJ
*1
M12 × 1
Indicators *2
Two clamping nuts
M18 × 1
*1. No U suffix: 6-dia. Vinyl-insulated round cable
U suffix: 6-dia. Polyurethane insulated round cable,
Standard length: 300 mm
Toothed washer
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
Diagram 35 E2E-X10D@-M1GJ
E2E-X10D@-M1J-T
48
12
42 dia.
43
36
5
10
E2E-X10D@-M1TGJ-U *3
E2E-X10D1-M1TGJ
*1
M12 × 1
Indicators *2
*1. No U suffix: 6-dia. Vinyl-insulated round cable
U suffix: 6-dia. Polyurethane insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
M30 × 1.5
Two clamping nuts
Toothed washer
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
Pre-wired Connector Models (Unshielded)
38
33
9
Diagram 32 E2E-X8MD1-M1GJ
E2E-X8MD1-M1TGJ
21 dia.
17
7
4
10
9 dia.
*1
Indicators *2
Two clamping nuts
Toothed washer
M12 × 1
*1. 4-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
M12 × 1
34
E2E
43
38
12
Diagram 34 E2E-X14MD@-M1GJ
E2E-X14MD1-M1TGJ
29 dia.
24
4
10
10
14.8 dia.
*1
M12 × 1
Indicators*2
M18 × 1
*1. 6-dia. vinyl-insulated round cable, Standard
length: 300 mm
Two clamping nuts
Toothed washer
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)
Diagram 36 E2E-X20MD1-M1GJ
E2E-X20MD1-M1TGJ
48
43
12
42 dia.
36
13
5
10
26.8 dia.
*1
M12 × 1
Indicators*2
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable,
Two clamping nuts
Toothed washer
Standard length: 300 mm
*2. Operation indicator (red),
Setting indicator (green)
Dimensions for Proximity Sensors with Sensor I/O Connectors
Dimensions with the XS2F Connected (Unit:mm)
Shielded Models
Unshielded Models
Dimension
Sensor diameter
L1
L2
Straight Connectors
Straight Connectors
M8
Approx. 75
Approx. 80
Approx. 85
Approx. 85
Approx. 90
Approx. 62
Approx. 67
Approx. 72
Approx. 72
Approx. 77
DC
M12*
AC
L1
L1
L-shape Connectors
L-shape Connectors
M18
M30
* The overall length of the Sensor is different between AC and DC
Models for Sensors with diameters of M12. This will change the
dimension when the I/O Connector is connected.
Dimensions with the XS3F Connected (Unit:mm)
Dimension
Sensor diameter
L2
L2
L1
L2
M8
Approx. 65
Approx. 54
Accessories (Order Separately)
Sensor I/O Connectors
Refer to Introduction to Sensor I/O Connectors for details.
Mounting Brackets
Protective Covers
Sputter Protective Covers
Refer to Y92@ for details.
35
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.
相关型号:
E2E-X2D2-N
Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E
OMRON
E2E-X2D2-U
Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E
OMRON
E2E-X2E1-M1
Your Search for Proximity Sensors Starts with the World-leading Performance and Quality of the E2E
OMRON
©2020 ICPDF网 联系我们和版权申明