E2E-X4B3D12-M1TJ0.3M [OMRON]
Inductive Sensor,;型号: | E2E-X4B3D12-M1TJ0.3M |
厂家: | OMRON ELECTRONICS LLC |
描述: | Inductive Sensor, |
文件: | 总108页 (文件大小:32461K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
N
E
W
Proximity Sensors
DC 3-Wire Models
E2E NEXT Series
Exceptional
sensing
range*
9mm
[Quadruple distance model of M12 sized]
standardized design
* Based on December 2018 OMRON investigation.
Proximity Sensors E2E NEXT Series
2
Enables easier and standardi
previously not possible
PREMIUM Model
Easy design
Standardized design
Exceptional
sensing range
The PREMIUM Model, which has a longer detection range compared to
previous models, allows for more spacious designs with less risk of
contact. It also enables you to standardize your designs by letting you
adopt a single one-size model instead of multiple models of different
sizes.
*1
[
]
M12
*2
9
mm
Quadruple distance model
9 mm [M12]
*1. Based on December 2018 OMRON investigation.
Triple distance model
*2. Quadruple distance models of M12 sized
P.4-7
6 mm [M12]
BASIC Model
Double distance model
In addition to our HIGH SPEC Models, we also offer
mid/short-distance BASIC Models, to meet various facility
design requirement specifications.
4 mm [M12]
Single distance model
2 mm [M12]
3
zed designs
New standards for usability
Early error detection
all new E2E Sensors can be monitored
location,
P.8
with IO-Link
1
Quick recovery
replaceable
second
P.10
P.10
(adaptor)
with e-jig
10
view
degree
with high visibility LED indicator
360
Less unexpected facility stoppages
Strong resistance to
cutting oil
P.12
*3
oil resistance
2-year
*3. Pre-wired models and pre-wired connector models.
PREMIUM Model
Proximity Sensors E2E NEXT Series
4
Equipped with exceptional sensing range*
to enable collision-free
sensor installation
Easy design
Enables designs with more distance between the sensor and the sensing object, thereby reducing unexpected
facility stoppages due to collision and false detection, which occurred with previous proximity sensors.
Previous models
[Quadruple distance
ized]
Exceptional
E2E NEXT
sensing range*
9mm
* Based on December 2018 OMRON investigation
Stable detection without collision
5
Allows for more spacious design with
less risk of contact
With previous models, to avoid false detections, you were forced to adopt sensor
installation designs that risked contact. The E2E NEXT PREMIUM Proximity Sensor can
detect accurately from a greater distance, which means you can adopt designs with
more space and less risk of contact.
■
Approximately double the sensing distance of previous models
Sensing distance comparisons (Quadruple distance models)
Shielded
Previous
2 mm
models
M8
E2E NEXT
4 mm
Exceptional sensing range*
Previous
models
4 mm
* Based on December 2018 OMRON investigation.
E2E NEXT
M12
M18
9 mm
8 mm
Previous models
E2E NEXT
14 mm
15 mm
Previous models
E2E NEXT
M30
23 mm
Longest in the series
50 mm
Unshielded
Previous models
E2E NEXT
30 mm
Less false detection even when a stationary gets away from the sensor due to
equipment vibration
Previous models
E2E NEXT
The equipment vibration widens the
Long-distance detection enhances the degree
distance between a stationary and a sensor
to cause false detection and facility stoppages.
of the detection margin.
even when a stationary gets away.
Stable detection
Stable
detection
False
detection
4 mm
9 mm
Spindle presence detection
* Quadruple distance models of M12 sized
PROX3 hybrid circuitry with Thermal Distance Control 2 eliminates ambient temperature influence to enable extended sensing ranges.
Sensing distance fluctuation due to ambient temperature
Proximity sensors with longer sensing distance require increased sensitivity. However, with the increased
sensitivity, temperature changes will have bigger influence in sensing distance, and differences between
individual sensors will be bigger. E2E NEXT Proximity Sensors (3-wire models) solve these issues by newly
implementing Thermal Distance Control 2, a technology to enable extended sensing ranges. It enables
in-line measurements of each sensor’s temperature characteristics, using multiple temperature points, in
IoT-enabled production processes. The optimal correction values are then calculated based on our unique
algorithm. The values are written into the
Before correction
Sensing object
analog digital hybrid IC (PROX3) for shipping
After correction
Before correction
to minimize differences between sensors
and the influence of temperature changes
that may occur in the customer’s environ-
ments.
Corrected with high precision
using measurement data from
multiple temperature points
After correction
Sensing object
-25
+25
+70
℃
℃
℃
Patent Pending
Thermal Distance Control 2 technology reduces the extent of error
Ambient temperature
Proximity Sensors E2E NEXT Series
PREMIUM Model
6
*1
Exceptional sensing range
allows you to standardize your
Standardized
design
design with a single one-size model
Ensures equivalent sensing distance while being one size smaller than previous models. Equipment and facilities formerly designed to use
sensors of multiple sizes can now be designed to use sensors that are all the same size, allowing you to standardize your designs.
Case where either M12 or M18 is used depending on sensing distance
Previous models
Two different types of hole designs were required for the sensing distance of 4 mm and 8 mm.
Required sensing distance
8 mm
Required sensing distance
4 mm
M18
M12
One size
covers both
Sensing distance
2
*
9 mm
E2E NEXT
The sensing distance of M12 is 9 mm,
which means M12 can cover objects
previously covered by M18. Hole designs
can be standardized to fit M12 only.
M12
*1. Based on December 2018 OMRON investigation.
*2. Quadruple distance models
Four types of M12 size sensors are available to meet the need for variable sensing distances for different installation sites.
Quadruple distance model
Triple distance model
Double distance model
Single distance model
7
Easy to install, even where space is limited
E2E NEXT PREMIUM Model Proximity Sensors ensure equivalent sensing distance while being one size smaller
than previous models, allowing you to install them in spaces where conventional sensors were too big to fit.
Proximity sensors could not be
Previous
models
installed due to limited space.
M18
They can be installed due to
E2E NEXT
limited space.
One size smaller to allow you to
install proximity sensors where
space is limited.
M12
Note: When installing proximity sensors, make sure to factor the influence of surrounding metal into your designs.
(Refer to ●Influence of Surrounding Metal upon Design on page 62 and page 80 for details.)
■
One size smaller than previous models
Size comparisons between models with equivalent sensing distance (“E2E NEXT”refers to quadruple distance models)
M12
M8
M18
M12
M30
M18
Previous models
E2E NEXT
Previous models
Sensing distance
8 mm
E2E NEXT
Sensing distance
9 mm
Previous models
Sensing distance
15 mm
E2E NEXT
Sensing distance
14 mm
Sensing distance Sensing distance
4 mm
4 mm
Unifying the model types to reduce the number of parts kept in inventory.
Two models (M12 and M18)
stocked
The extended range of the new sensors
allows you to reduce the sensor size from
M18 down to M12.
Previous
models
E2E NEXT
M18
M12
Sensing distance
8 mm
Sensing distance
M12
9 mm
Sensing distance
4 mm
Proximity Sensors E2E NEXT Series
PREMIUM Model
BASIC Model
8
New standards for usability
Early error detection
Enables facility designs that allow for
early discovery of the site and
substance of failure
Less time required from failure to recovery
(MTTR: Mean Time To Recovery).
Excessive
proximity
Detects sensor failures
When NO cable is disconnected
through two output types,
Normal operation Failure occurred
NO and NC
Enables failure discovery by wiring two
+V
NC
outputs, NO and NC.
0V
NO
9
* Screen is a
conceptual
illustration.
sensor failure from a single location
Sensor No.12 is too
close to the sensing
object.
By using the IO-Link Master to connect proximity sensors to your
controller, you can use your monitor (HMI) for early discovery of the
site and substance of proximity sensor failures.
HMI
Controller
IO-Link Master
Enables predictive maintenance through condition monitoring
Connecting sensors with controllers using IO-Link Master enables to
send information necessary for stable operation to host devices. This
enables condition monitoring and failure detection of sensors, which
in turn contribute to predictive maintenance of equipment and
facilities. You can also increase the productivity of your facility by
accumulating information in databases and feeding analysis results
back to equipment on the site.
Cloud
Factory
Manufacturing site
Setup: Integrated software environment
(Sysmac Studio)
Database
Notify sensor status
Configured and monitored on a one-tool, one-connection basis
Import information on sensors inside equipment
Controller
Feed sensor status analysis
results back to the site
Detection margin and present value
data such as temperature inside the sensor
IO-Link Master
Predictive
maintenance
IO-Link Master
IO-Link Sensor
IO-Link Sensor
Proximity Sensors E2E NEXT Series
PREMIUM Model
BASIC Model
10
* Applies only to the description of the high-brightness LED indicator.
New standards for usability
Quick recovery
Enables facility designs that allow for
quick recovery in case of failure
Less time required from failure to recovery
(MTTR: Mean Time To Recovery).
All around visible high-brightness
LED indicator
Adopts high-brightness LED that is more luminous and
visible than those in previous models. The indicator is visible
from all angles, reducing the time required for operation
checks after sensor replacement.
Visible even in areas deep inside the equipment,
allowing for quicker replacement
11
Replacements in as little as 10 seconds* using e-jig
Using e-jig eliminates the need for adjustment so that anyone can install in the same position.
A lot of time required to adjust to the optimum distance.
Adjustment position varies depending on the worker’s skill and
makes detection unstable.
Previous
models
2. Check the detection status with the
workpiece.
Repeat steps
1 to 3 until
detection is
stabilized.
1. Fasten the sensor temporarily.
4. Finish by fixing the nut.
3. Loosen the nut and adjust the distance.
Replacement time reduced significantly to approx.
*
10 sec.
E2E NEXT
Eliminating the need for adjustment allows for installation in the same position by any worker.
1. Insert the sensor into an e-jig.
Patent Pending
The O-ring blocks the ingress of foreign
O-ring
matter, including cutting oil, into the e-jig
and ensures positioning precision (IP67G).
2. Then just fix the sensor.
* Time required to adjust the distance when installing a sensor.
Based on OMRON investigation.
Easily upgrade existing facilities to enable “10-second* proximity sensor replacements”
The HIGH SPEC Model’s sensing distance is approximately twice that of previous models. For example, the sensing distance of the quadruple distance model of M12 sized is 9 mm, which is about the same as
conventional M18 models. Using these sensors together with the e-jig allows you to easily upgrade your existing facilities so that you can replace their sensors in just 10 seconds.*
1. Dismount the M18 proximity sensor from
the existing facility.
2. Mount an M18-sized e-jig.
3. Insert an E2E NEXT Series M12
Proximity Sensor into the e-jig.
M18
M18
M12
8 mm
9 mm
Proximity sensor
M18
E2E NEXT
M12
e-jig
Proximity Sensors E2E NEXT Series
PREMIUM Model
12
BASIC Model
New standards for usability
Less unexpected facility stoppages
Excellent environmental resistance
enables robust facility design
Reduces sudden facility stoppages by reducing the number of failures, even in severe environments.
Unexpected component failures:
Approx. 30 % are caused by cutting oil.
Other causes
Voltage or
noise
Cutting oil
Dust, dirt, or
spatter
Temperature
Shock or vibration
Environmental Causes of Component Failures
■
(Based on June 2016 OMRON investigation.)
13
Cables with enhanced oil resistance shut out cutting oil for 2 years*
Our new PVC compound protects against damage caused by swelling, deterioration or cracking, preventing oil from seeping into and
destroying internal circuits. Designed to resist oil ingress for up to two years.
■Two years* of stable operation verified by OMRON’s unique evaluation technology
Verified 2-year oil resistance,*
based on IP67G and
Previous
models
E2E NEXT
Cables damaged by cutting oil
OMRON’s oil-resistant mponent evaluation standards
der
environments where
OMRON’s E2E NEXT Series Proximity Sensors use
PVC cables with enhanced oil resistance, and have
been evaluated according to IP67G of JIS C 0920,
and also OMRON’s own, even stricter evaluation
standards for oil-resistant components.
r-soluble cutting oil is used.
Oil resistance:
2 years*
OMRON’s Oil-resistant Component Evaluation Standards
Oil type
A1 (water-soluble cutting oil)
1,000 hours of machining
55 °C
Evaluation time
Evaluation temperature
Dilution concentration
Criteria
IP67G
Oil type
Evaluation time
N3 (water-insoluble cutting oil)
48 hours
Undiluted
Evaluation temperature Room temperature
Appearance, performance, and
no label text loss
Dilution concentration
Criteria
Appearance and performance
(Illustration)
(Illustration)
■Two years* of stable operation verified for pre-wired connector models as well, using
similar oil resistance tests
Delivers 2-year oil resistance* by adopting technologies unique
•
to OMRON and PVC cables with enhanced oil resistance.
Patent Pending
Smartclick connector cables block the ingress of cutting oil,
and with the same torque, no matter who connects them.
•
Fit with just 1/8 of a
is a registered trademark of
OMRON Corporation.
For machining processes where the amount
Oil Resistance:
of splashing cutting oil is large,
oil-resistant
4 years
Proximity Sensors E2ER/E2ERZ
Cat. No. Y215
*•Applicable oil types: specified in JIS K 2241:2000
“2-year oil resistance” refers to median values (=Typical values) of the product designs and the oil-resistance performance evaluation results.
Products to be shipped will have around 2 years of oil resistance; actual oil resistance will vary depending on the product.
•The pre-wired connector model has a verified oil resistance of 2 years when mated with XS5 NEXT series round oil-resistant connectors.
This value has not been verified for connector models(M1/M3/M5).
IP69K compliant for water resistance and wash resistance
IEC 60529 compliant. Ensures water resistance during hot pressure washing, where equipment is washed intensively with high-pressure water
or steam. (8,000 to 10,000 kPa pressure, 80°C hot water, 30 seconds for each angle)
E2E/E2EQ NEXT Series
Selection Guide
E2E/E2EQ NEXT Series
DC 3-wire
(PREMIUM Model)
P15
Premium model capable of
long-sensing distance with
enhanced user-friendliness
3-wire Models
Proximity Sensor
E2E/E2EQ NEXT Series
DC 3-wire
(BASIC Model)
P15
Basic model with the same
sensing distance as the
previous model, but with
enhanced user-friendliness
E2E/E2EQ NEXT Series
DC 2-wire
P67
2-wire Models
Oil-resistant model that minimizes
failures caused by cutting oils
(oil- and bending-resistant type
is also available)
XS5 NEXT Series *
2 years of oil resistance
P87
M12
Connector Cable
XS5 Series
BASIC Model
P94
Previous basic model
XS3W-M8/XS3F-M8 Series
P102
M8
* Applicable oil types: specified in JIS K 2241:2000
“2-year oil resistance” refers to median values (=Typical values) of the product designs and the oil-resistance performance evaluation results.
Products to be shipped will have around 2 years of oil resistance; actual oil resistance will vary depending on the product.
The Pre-wired Connector Model has a verified oil resistance of 2 years when mated with XS5 NEXT Series round oil-resistant connectors.
14
Proximity Sensor
E2E/E2EQ NEXT Series
DC 3-Wire
Enables easier and standardized designs
previously not possible
• The world's longest sensing distance*1
Nearly double the sensing distance of previous
• With high-brightness LED, the indicator is visible anywhere from 360°.
• Only 10 Seconds*2 to Replace a Proximity Sensor with the "e-jig"
(Mounting Sleeve).
• Cables with enhanced oil resistance enabled 2-year oil resistance*3.
4
• IP69K compliant for water resistance and wash resistance
• Comes in a wide variation to make sensor selection easy
*
• UL certification (UL60947-5-2)*5 and CSA certification (CSA
For the most recent information on models that have been
certified for safety standards, refer to your OMRON website.
C22.2 UL60947-5-2-14)
*1. Based on December 2018 OMRON investigation.
*2. Time required to adjust the distance when installing a Sensor. Based on OMRON investigation.
*3. Refer to Ratings and Specifications for details. However, E2E Connector Models and E2EQ series is excluded.
*4. E2EQ series is excluded.
*5. M8 (4-pin) Connector Models are not UL certified.
Be sure to read Safety Precautions on page 61.
Features
PREMIUM Model
Quadruple distance model
Easy design
Standardized design
9mm [M12]
Exceptional
sensing
[M12]
*6
range
9
mm*7
The PREMIUM Model, which has a longer detection
range compared to previous models, allows for
more spacious designs with less risk of contact. It
also enables you to standardize your designs by
letting you adopt a single one-size model instead of
multiple models of different sizes.
Triple distance model
6mm [M12]
*6. Based on December 2018 OMRON investigation.
*7. Quadruple distance models of M12 sized
New standards for usability
Early error detection
Less unexpected
facility stoppages
BASIC Model
all new E2E Sensors
location,
Strong resistance to
cutting oil
can be monitored
In addition to our HIGH SPEC Models, we
also offer mid/short-distance BASIC
Models, to meet various facility design
requirement specifications.
1
*3
2-year
with IO-Link
oil resistance *9
*9. E2E Connector Models and E2EQ series is
excluded.
Quick recovery
Double distance model
replaceable
second
4mm [M12]
with e-jig (adaptor)
*8
10
view
Single distance model
degree
with high visibility
LED indicator
2mm [M12]
360°
*8. Time required to adjust the distance when installing a Sensor. Based on OMRON investigation.
15
E2E/E2EQ NEXT Series
E2E/E2EQ NEXT Series Model Number Legend
DC 3-wire
(1)
(2) (3) (4) (5) (6) (7) (8) (9) (10)
(11)
-
-
-
-
E2E
X
No.
Type
Code
Blank
Q
Meaning
Without spatter-resistant coating
(1)
(2)
(3)
Case
With spatter-resistant coating
Sensing distance (Unit: mm)
(R: Indication of decimal point)
Sensing distance
Shielding
Number
Blank
M
Shielded
Unshielded
B
PNP open collector
NPN open collector
Normally open (NO)
Normally closed (NC)
Normally open, Normally closed (NO+NC)
Non IO-Link compliant
COM2 (38.4 kbps)
COM3 (230.4 kbps)
Standard
(4)
(5)
Output configuration
Operation mode
C
1
2
3
Blank
D
(6)
(7)
IO-Link baud rate
Body size
T
Blank
L
Long Body
8
M8
12
M12
(8)
Size
18
M18
30
M30
Blank
M1
M3
M5
M1TJ
Pre-wired Models
M12 Connector Models
M8 (4-pin) Connector Models
M8 (3-pin) Connector Models
M12 Pre-wired Smartclick Connector Models
(9)
Connection method
M12 Pre-wired Smartclick Connector Models
Robot (bending-resistant) cable
M1TJR
Blank
R
Standard PVC cable
Robot (bending-resistant) cable
Cable length
(10)
(11)
Cable specifications *
Cable length
Number M
* (10) is only shown in the model number of Pre-wired Models.
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
Models are not available for all combinations of code numbers.
16
E2E/E2EQ NEXT Series
Ordering Information
PREMIUM Model
E2E NEXT Series (Quadruple distance model)
DC 3-wire [Refer to Dimensions on page 64.]
Shielded *1
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
E2E-X4B1T8 2M
IO-Link (COM2) *5
E2E-X4B1D8 2M
--- *5
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
E2E-X4C18 2M
38 mm
*3
-
E2E-X4B28 2M
E2E-X4C28 2M
Pre-wired (2 m) *2
E2E-X4B1TL8 2M
E2E-X4B1DL8 2M
E2E-X4C1L8 2M
48 mm
-
E2E-X4B2L8 2M
E2E-X4C2L8 2M
E2E-X4B1T8-M1TJ 0.3M
E2E-X4B1D8-M1TJ 0.3M
E2E-X4B28-M1TJ 0.3M
E2E-X4B1DL8-M1TJ 0.3M
E2E-X4B2L8-M1TJ 0.3M
E2E-X4B1D8-M1
E2E-X4C18-M1TJ 0.3M
E2E-X4C28-M1TJ 0.3M
E2E-X4C1L8-M1TJ 0.3M
E2E-X4C2L8-M1TJ 0.3M
E2E-X4C18-M1
38 mm
*4
M12 Pre-wired
Smartclick
Connector (0.3 m)
-
E2E-X4B1TL8-M1TJ 0.3M
48 mm
43 mm
53 mm
39 mm
49 mm
39 mm
49 mm
-
E2E-X4B1T8-M1
-
E2E-X4B28-M1
E2E-X4C28-M1
M8
(4 mm)
M12 Connector
E2E-X4B1TL8-M1
E2E-X4B1DL8-M1
E2E-X4B2L8-M1
E2E-X4C1L8-M1
-
E2E-X4C2L8-M1
E2E-X4B1T8-M3
E2E-X4B1D8-M3
E2E-X4C18-M3
-
E2E-X4B28-M3
E2E-X4C28-M3
M8 Connector
(4-pin)
E2E-X4B1TL8-M3
E2E-X4B1DL8-M3
E2E-X4B2L8-M3
E2E-X4C1L8-M3
-
E2E-X4C2L8-M3
E2E-X4B1T8-M5
E2E-X4B1D8-M5
E2E-X4C18-M5
-
E2E-X4B28-M5
E2E-X4C28-M5
M8 Connector
(3-pin)
E2E-X4B1TL8-M5
E2E-X4B1DL8-M5
E2E-X4B2L8-M5
E2E-X4C1L8-M5
-
E2E-X4C2L8-M5
E2E-X9B1T12 2M
E2E-X9B1D12 2M
E2E-X9C112 2M
47 mm
*3
-
E2E-X9B212 2M
E2E-X9C212 2M
Pre-wired (2 m) *2
E2E-X9B1TL12 2M
E2E-X9B1DL12 2M
E2E-X9B2L12 2M
E2E-X9C1L12 2M
E2E-X9C2L12 2M
E2E-X9C112-M1TJ 0.3M
E2E-X9C212-M1TJ 0.3M
E2E-X9C1L12-M1TJ 0.3M
E2E-X9C2L12-M1TJ 0.3M
E2E-X9C112-M1
69 mm
-
E2E-X9B1T12-M1TJ 0.3M
E2E-X9B1D12-M1TJ 0.3M
E2E-X9B212-M1TJ 0.3M
E2E-X9B1DL12-M1TJ 0.3M
E2E-X9B2L12-M1TJ 0.3M
E2E-X9B1D12-M1
47 mm
*4
M12 Pre-wired
Smartclick
Connector (0.3 m)
-
M12
(9 mm)
E2E-X9B1TL12-M1TJ 0.3M
69 mm
48 mm
70 mm
-
E2E-X9B1T12-M1
-
E2E-X9B212-M1
E2E-X9C212-M1
M12 Connector
E2E-X9B1TL12-M1
E2E-X9B1DL12-M1
E2E-X9B2L12-M1
E2E-X9C1L12-M1
E2E-X9C2L12-M1
E2E-X14C118 2M
E2E-X14C218 2M
E2E-X14C1L18 2M
E2E-X14C2L18 2M
E2E-X14C118-M1TJ 0.3M
E2E-X14C218-M1TJ 0.3M
E2E-X14C1L18-M1TJ 0.3M
E2E-X14C2L18-M1TJ 0.3M
E2E-X14C118-M1
E2E-X14C218-M1
E2E-X14C1L18-M1
E2E-X14C2L18-M1
-
E2E-X14B1T18 2M
E2E-X14B1D18 2M
E2E-X14B218 2M
55 mm
*3
-
Pre-wired (2 m) *2
E2E-X14B1TL18 2M
E2E-X14B1DL18 2M
E2E-X14B2L18 2M
E2E-X14B1D18-M1TJ 0.3M
E2E-X14B218-M1TJ 0.3M
E2E-X14B1DL18-M1TJ 0.3M
E2E-X14B2L18-M1TJ 0.3M
E2E-X14B1D18-M1
E2E-X14B218-M1
77 mm
-
E2E-X14B1T18-M1TJ 0.3M
-
55 mm
*4
M12 Pre-wired
Smartclick
Connector (0.3 m)
M18
(14 mm)
E2E-X14B1TL18-M1TJ 0.3M
77 mm
53 mm
75 mm
-
E2E-X14B1T18-M1
-
M12 Connector
E2E-X14B1TL18-M1
-
E2E-X14B1DL18-M1
E2E-X14B2L18-M1
17
E2E/E2EQ NEXT Series
PREMIUM Model
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *5
E2E-X23B1D30 2M
--- *5
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
E2E-X23B1T30 2M
E2E-X23C130 2M
60 mm
*4
-
E2E-X23B230 2M
E2E-X23C230 2M
Pre-wired (2 m) *2
E2E-X23B1TL30 2M
E2E-X23B1DL30 2M
E2E-X23B2L30 2M
E2E-X23C1L30 2M
E2E-X23C2L30 2M
E2E-X23C130-M1TJ 0.3M
E2E-X23C230-M1TJ 0.3M
E2E-X23C1L30-M1TJ 0.3M
E2E-X23C2L30-M1TJ 0.3M
E2E-X23C130-M1
E2E-X23C230-M1
E2E-X23C1L30-M1
E2E-X23C2L30-M1
82 mm
-
E2E-X23B1T30-M1TJ 0.3M
-
E2E-X23B1D30-M1TJ 0.3M
E2E-X23B230-M1TJ 0.3M
E2E-X23B1DL30-M1TJ 0.3M
E2E-X23B2L30-M1TJ 0.3M
E2E-X23B1D30-M1
60 mm
*4
M12 Pre-wired
Smartclick
Connector (0.3 m)
M30
(23 mm)
E2E-X23B1TL30-M1TJ 0.3M
82 mm
58 mm
80 mm
-
E2E-X23B1T30-M1
-
E2E-X23B230-M1
M12 Connector
E2E-X23B1TL30-M1
-
E2E-X23B1DL30-M1
E2E-X23B2L30-M1
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 62.
*2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2E-X9B1D12 5M)
*3. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X9B1D12-R 2M/
E2E-X9B1D12-R 5M)
*4. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with "R" in the model number. (Example: E2E-
X9B1D12-M1TJR 0.3M)
*5. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
18
E2E/E2EQ NEXT Series
PREMIUM Model
E2E NEXT Series (Quadruple distance model)
DC 3-wire [Refer to Dimensions on page 64.]
Unshielded
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X8MB1D8 2M
--- *4
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
E2E-X8MB1T8 2M
E2E-X8MC18 2M
38 mm
*2
-
E2E-X8MB28 2M
E2E-X8MC28 2M
Pre-wired (2 m) *1
E2E-X8MB1TL8 2M
E2E-X8MB1DL8 2M
E2E-X8MB2L8 2M
E2E-X8MC1L8 2M
48 mm
-
E2E-X8MC2L8 2M
E2E-X8MB1T8-M1TJ 0.3M
E2E-X8MB1D8-M1TJ 0.3M
E2E-X8MB28-M1TJ 0.3M
E2E-X8MB1DL8-M1TJ 0.3M
E2E-X8MB2L8-M1TJ 0.3M
E2E-X8MB1D8-M1
E2E-X8MC18-M1TJ 0.3M
E2E-X8MC28-M1TJ 0.3M
E2E-X8MC1L8-M1TJ 0.3M
E2E-X8MC2L8-M1TJ 0.3M
E2E-X8MC18-M1
38 mm
*3
M12 Pre-wired
Smartclick
Connector (0.3 m)
-
E2E-X8MB1TL8-M1TJ 0.3M
48 mm
43 mm
53 mm
39 mm
49 mm
39 mm
49 mm
-
E2E-X8MB1T8-M1
-
E2E-X8MB28-M1
E2E-X8MC28-M1
M8
(8 mm)
M12 Connector
E2E-X8MB1TL8-M1
E2E-X8MB1DL8-M1
E2E-X8MB2L8-M1
E2E-X8MC1L8-M1
-
E2E-X8MC2L8-M1
E2E-X8MB1T8-M3
E2E-X8MB1D8-M3
E2E-X8MC18-M3
-
E2E-X8MB28-M3
E2E-X8MC28-M3
M8 Connector
(4-pin)
E2E-X8MB1TL8-M3
E2E-X8MB1DL8-M3
E2E-X8MB2L8-M3
E2E-X8MC1L8-M3
-
E2E-X8MC2L8-M3
E2E-X8MB1T8-M5
E2E-X8MB1D8-M5
E2E-X8MC18-M5
-
E2E-X8MB28-M5
E2E-X8MC28-M5
M8 Connector
(3-pin)
E2E-X8MB1TL8-M5
E2E-X8MB1DL8-M5
E2E-X8MB2L8-M5
E2E-X8MC1L8-M5
-
E2E-X8MC2L8-M5
E2E-X16MB1T12 2M
E2E-X16MB1D12 2M
E2E-X16MB212 2M
E2E-X16MC112 2M
E2E-X16MC212 2M
E2E-X16MC1L12 2M
E2E-X16MC2L12 2M
E2E-X16MC112-M1TJ 0.3M
E2E-X16MC212-M1TJ 0.3M
E2E-X16MC1L12-M1TJ 0.3M
E2E-X16MC2L12-M1TJ 0.3M
E2E-X16MC112-M1
E2E-X16MC212-M1
E2E-X16MC1L12-M1
E2E-X16MC2L12-M1
E2E-X30MC1L18 2M
E2E-X30MC2L18 2M
47 mm
*2
-
Pre-wired (2 m) *1
E2E-X16MB1TL12 2M
-
E2E-X16MB1DL12 2M
E2E-X16MB2L12 2M
E2E-X16MB1D12-M1TJ 0.3M
E2E-X16MB212-M1TJ 0.3M
E2E-X16MB1DL12-M1TJ 0.3M
E2E-X16MB2L12-M1TJ 0.3M
E2E-X16MB1D12-M1
E2E-X16MB212-M1
E2E-X16MB1DL12-M1
E2E-X16MB2L12-M1
E2E-X30MB1DL18 2M
E2E-X30MB2L18 2M
69 mm
E2E-X16MB1T12-M1TJ 0.3M
47 mm
*3
M12 Pre-wired
Smartclick
Connector (0.3 m)
-
M12
(16 mm)
E2E-X16MB1TL12-M1TJ 0.3M
69 mm
48 mm
70 mm
-
E2E-X16MB1T12-M1
-
M12 Connector
E2E-X16MB1TL12-M1
-
E2E-X30MB1TL18 2M
-
77 mm
*2
Pre-wired (2 m) *1
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO
NC
E2E-X30MB1TL18-M1TJ 0.3M
-
E2E-X30MB1DL18-M1TJ 0.3M
E2E-X30MB2L18-M1TJ 0.3M
E2E-X30MC1L18-M1TJ 0.3M
E2E-X30MC2L18-M1TJ 0.3M
M18
(30 mm)
77 mm
*3
NO
NC
NO
NC
E2E-X30MB1TL18-M1
E2E-X30MB1DL18-M1
E2E-X30MB2L18-M1
E2E-X50MB1DL30 2M
E2E-X50MB2L30 2M
E2E-X30MC1L18-M1
E2E-X30MC2L18-M1
E2E-X50MC1L30 2M
E2E-X50MC2L30 2M
M12 Connector
75 mm
-
E2E-X50MB1TL30 2M
-
97 mm
*2
Pre-wired (2 m) *1
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO
NC
E2E-X50MB1TL30-M1TJ 0.3M
-
E2E-X50MB1DL30-M1TJ 0.3M
E2E-X50MB2L30-M1TJ 0.3M
E2E-X50MC1L30-M1TJ 0.3M
E2E-X50MC2L30-M1TJ 0.3M
M30
(50 mm)
97 mm
*3
NO
NC
E2E-X50MB1TL30-M1
-
E2E-X50MB1DL30-M1
E2E-X50MB2L30-M1
E2E-X50MC1L30-M1
E2E-X50MC2L30-M1
M12 Connector
95 mm
*1. Models with 5-m cable length are also available (Example: E2E-X16MB1D12 5M)
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X16MB1D12-R
2M/E2E-X16MB1D12-R 5M)
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-
X16MB1D12-M1TJR 0.3M)
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
19
E2E/E2EQ NEXT Series
PREMIUM Model
E2E NEXT Series (Triple distance model)
DC 3-wire [Refer to Dimensions on page 64.]
Shielded *1
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
E2E-X3B1T8 2M
IO-Link (COM2) *5
E2E-X3B1D8 2M
--- *5
NO
NC
E2E-X3C18 2M
38 mm
*3
-
E2E-X3B28 2M
E2E-X3C28 2M
Pre-wired (2 m) *2
NO
E2E-X3B1TL8 2M
E2E-X3B1DL8 2M
E2E-X3B2L8 2M
E2E-X3C1L8 2M
48 mm
NC
-
E2E-X3C2L8 2M
NO
E2E-X3B1T8-M1TJ 0.3M
E2E-X3B1D8-M1TJ 0.3M
E2E-X3B28-M1TJ 0.3M
E2E-X3B1DL8-M1TJ 0.3M
E2E-X3B2L8-M1TJ 0.3M
E2E-X3B1D8-M1
E2E-X3C18-M1TJ 0.3M
E2E-X3C28-M1TJ 0.3M
E2E-X3C1L8-M1TJ 0.3M
E2E-X3C2L8-M1TJ 0.3M
E2E-X3C18-M1
38 mm
*4
M12 Pre-wired
Smartclick
Connector (0.3 m)
NC
-
NO
E2E-X3B1TL8-M1TJ 0.3M
48 mm
43 mm
53 mm
39 mm
49 mm
39 mm
49 mm
NC
-
NO
E2E-X3B1T8-M1
NC
-
E2E-X3B28-M1
E2E-X3C28-M1
M8
(3 mm)
M12 Connector
NO
E2E-X3B1TL8-M1
E2E-X3B1DL8-M1
E2E-X3B2L8-M1
E2E-X3C1L8-M1
E2E-X3C2L8-M1
E2E-X3C18-M3
NC
-
NO
E2E-X3B1T8-M3
E2E-X3B1D8-M3
NC
-
E2E-X3B28-M3
E2E-X3C28-M3
M8 Connector
(4-pin)
NO
E2E-X3B1TL8-M3
E2E-X3B1DL8-M3
E2E-X3B2L8-M3
E2E-X3C1L8-M3
E2E-X3C2L8-M3
E2E-X3C18-M5
NC
-
NO
E2E-X3B1T8-M5
E2E-X3B1D8-M5
NC
-
E2E-X3B28-M5
E2E-X3C28-M5
M8 Connector
(3-pin)
NO
E2E-X3B1TL8-M5
E2E-X3B1DL8-M5
E2E-X3B2L8-M5
E2E-X3C1L8-M5
E2E-X3C2L8-M5
E2E-X6C112 2M
NC
-
NO
E2E-X6B1T12 2M
E2E-X6B1D12 2M
E2E-X6B212 2M
47 mm
*3
NC
-
E2E-X6C212 2M
NO+NC
NO
-
E2E-X6B3D12 2M
E2E-X6B1DL12 2M
E2E-X6B2L12 2M
E2E-X6C312 2M
Pre-wired (2 m) *2
E2E-X6B1TL12 2M
E2E-X6C1L12 2M
E2E-X6C2L12 2M
E2E-X6C3L12 2M
E2E-X6C112-M1TJ 0.3M
E2E-X6C212-M1TJ 0.3M
E2E-X6C312-M1TJ 0.3M
E2E-X6C1L12-M1TJ 0.3M
E2E-X6C2L12-M1TJ 0.3M
E2E-X6C3L12-M1TJ 0.3M
E2E-X6C112-M1
69 mm
NC
-
NO+NC
NO
-
E2E-X6B3DL12 2M
E2E-X6B1D12-M1TJ 0.3M
E2E-X6B212-M1TJ 0.3M
E2E-X6B3D12-M1TJ 0.3M
E2E-X6B1DL12-M1TJ 0.3M
E2E-X6B2L12-M1TJ 0.3M
E2E-X6B3DL12-M1TJ 0.3M
E2E-X6B1D12-M1
E2E-X6B212-M1
E2E-X6B1T12-M1TJ 0.3M
47 mm
*4
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M12
(6 mm)
E2E-X6B1TL12-M1TJ 0.3M
69 mm
48 mm
70 mm
NC
-
NO+NC
NO
-
E2E-X6B1T12-M1
NC
-
E2E-X6C212-M1
NO+NC
NO
-
E2E-X6B3D12-M1
E2E-X6B1DL12-M1
E2E-X6B2L12-M1
E2E-X6B3DL12-M1
E2E-X6C312-M1
M12 Connector
E2E-X6B1TL12-M1
E2E-X6C1L12-M1
E2E-X6C2L12-M1
E2E-X6C3L12-M1
NC
-
-
NO+NC
20
E2E/E2EQ NEXT Series
PREMIUM Model
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *5
E2E-X12B1D18 2M
--- *5
NO
NC
E2E-X12B1T18 2M
E2E-X12C118 2M
55 mm
*3
-
E2E-X12B218 2M
E2E-X12C218 2M
NO+NC
NO
-
E2E-X12B3D18 2M
E2E-X12C318 2M
Pre-wired (2 m) *2
E2E-X12B1TL18 2M
E2E-X12B1DL18 2M
E2E-X12B2L18 2M
E2E-X12C1L18 2M
77 mm
NC
-
E2E-X12C2L18 2M
NO+NC
NO
-
E2E-X12B3DL18 2M
E2E-X12B1D18-M1TJ 0.3M
E2E-X12B218-M1TJ 0.3M
E2E-X12B3D18-M1TJ 0.3M
E2E-X12B1DL18-M1TJ 0.3M
E2E-X12B2L18-M1TJ 0.3M
E2E-X12B3DL18-M1TJ 0.3M
E2E-X12B1D18-M1
E2E-X12C3L18 2M
E2E-X12B1T18-M1TJ 0.3M
E2E-X12C118-M1TJ 0.3M
E2E-X12C218-M1TJ 0.3M
E2E-X12C318-M1TJ 0.3M
E2E-X12C1L18-M1TJ 0.3M
E2E-X12C2L18-M1TJ 0.3M
E2E-X12C3L18-M1TJ 0.3M
E2E-X12C118-M1
55 mm
*4
NC
-
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
M18
(12 mm)
E2E-X12B1TL18-M1TJ 0.3M
77 mm
53 mm
75 mm
NC
-
NO+NC
NO
-
E2E-X12B1T18-M1
NC
-
E2E-X12B218-M1
E2E-X12C218-M1
NO+NC
NO
-
E2E-X12B3D18-M1
E2E-X12C318-M1
M12 Connector
E2E-X12B1TL18-M1
E2E-X12B1DL18-M1
E2E-X12B2L18-M1
E2E-X12C1L18-M1
E2E-X12C2L18-M1
E2E-X12C3L18-M1
E2E-X22C130 2M
NC
-
NO+NC
NO
-
E2E-X12B3DL18-M1
E2E-X22B1D30 2M
E2E-X22B1T30 2M
60 mm
*3
NC
-
E2E-X22B230 2M
E2E-X22C230 2M
NO+NC
NO
-
E2E-X22B3D30 2M
E2E-X22C330 2M
Pre-wired (2 m) *2
E2E-X22B1TL30 2M
E2E-X22B1DL30 2M
E2E-X22B2L30 2M
E2E-X22C1L30 2M
82 mm
NC
-
E2E-X22C2L30 2M
NO+NC
NO
-
E2E-X22B3DL30 2M
E2E-X22B1D30-M1TJ 0.3M
E2E-X22B230-M1TJ 0.3M
E2E-X22B3D30-M1TJ 0.3M
E2E-X22B1DL30-M1TJ 0.3M
E2E-X22B2L30-M1TJ 0.3M
E2E-X22B3DL30-M1TJ 0.3M
E2E-X22B1D30-M1
E2E-X22C3L30 2M
E2E-X22B1T30-M1TJ 0.3M
E2E-X22C130-M1TJ 0.3M
E2E-X22C230-M1TJ 0.3M
E2E-X22C330-M1TJ 0.3M
E2E-X22C1L30-M1TJ 0.3M
E2E-X22C2L30-M1TJ 0.3M
E2E-X22C3L30-M1TJ 0.3M
E2E-X22C130-M1
60 mm
*4
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M30
(22 mm)
E2E-X22B1TL30-M1TJ 0.3M
82 mm
58 mm
80 mm
NC
-
NO+NC
NO
-
E2E-X22B1T30-M1
NC
-
E2E-X22B230-M1
E2E-X22C230-M1
NO+NC
NO
-
E2E-X22B3D30-M1
E2E-X22C330-M1
M12 Connector
E2E-X22B1TL30-M1
E2E-X22B1DL30-M1
E2E-X22B2L30-M1
E2E-X22C1L30-M1
E2E-X22C2L30-M1
E2E-X22C3L30-M1
NC
-
-
NO+NC
E2E-X22B3DL30-M1
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 62.
*2. Models with 5-m cable length are also available (Example: E2E-X6B1D12 5M)
*3. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X6B1D12-R 2M/
E2E-X6B1D12-R 5M)
*4. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-
X6B1D12-M1TJR 0.3M)
*5. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
21
E2E/E2EQ NEXT Series
PREMIUM Model
E2E NEXT Series (Triple distance model)
DC 3-wire [Refer to Dimensions on page 64.]
Unshielded
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
--- *4
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X6MB1D8 2M
NO
E2E-X6MB1T8 2M
E2E-X6MC18 2M
38 mm
*2
NC
NO
-
E2E-X6MB28 2M
E2E-X6MC28 2M
Pre-wired (2 m) *1
E2E-X6MB1TL8 2M
E2E-X6MB1DL8 2M
E2E-X6MC1L8 2M
48 mm
NC
-
E2E-X6MB2L8 2M
E2E-X6MC2L8 2M
NO
E2E-X6MB1T8-M1TJ 0.3M
E2E-X6MB1D8-M1TJ 0.3M
E2E-X6MB28-M1TJ 0.3M
E2E-X6MB1DL8-M1TJ 0.3M
E2E-X6MB2L8-M1TJ 0.3M
E2E-X6MB1D8-M1
E2E-X6MC18-M1TJ 0.3M
E2E-X6MC28-M1TJ 0.3M
E2E-X6MC1L8-M1TJ 0.3M
E2E-X6MC2L8-M1TJ 0.3M
E2E-X6MC18-M1
38 mm
*3
M12 Pre-wired
Smartclick
Connector (0.3 m)
NC
-
NO
E2E-X6MB1TL8-M1TJ 0.3M
48 mm
43 mm
53 mm
39 mm
49 mm
39 mm
49 mm
NC
-
NO
E2E-X6MB1T8-M1
NC
-
E2E-X6MB28-M1
E2E-X6MC28-M1
M8
(6 mm)
M12 Connector
NO
E2E-X6MB1TL8-M1
E2E-X6MB1DL8-M1
E2E-X6MB2L8-M1
E2E-X6MC1L8-M1
NC
-
E2E-X6MC2L8-M1
NO
E2E-X6MB1T8-M3
E2E-X6MB1D8-M3
E2E-X6MC18-M3
NC
-
E2E-X6MB28-M3
E2E-X6MC28-M3
M8 Connector
(4-pin)
NO
E2E-X6MB1TL8-M3
E2E-X6MB1DL8-M3
E2E-X6MB2L8-M3
E2E-X6MC1L8-M3
NC
-
E2E-X6MC2L8-M3
NO
E2E-X6MB1T8-M5
E2E-X6MB1D8-M5
E2E-X6MC18-M5
NC
-
E2E-X6MB28-M5
E2E-X6MC28-M5
M8 Connector
(3-pin)
NO
E2E-X6MB1TL8-M5
E2E-X6MB1DL8-M5
E2E-X6MB2L8-M5
E2E-X6MC1L8-M5
NC
-
E2E-X6MC2L8-M5
NO
E2E-X10MB1T12 2M
E2E-X10MB1D12 2M
E2E-X10MB212 2M
E2E-X10MC112 2M
E2E-X10MC212 2M
E2E-X10MC312 2M
E2E-X10MC1L12 2M
E2E-X10MC2L12 2M
E2E-X10MC3L12 2M
E2E-X10MC112-M1TJ 0.3M
E2E-X10MC212-M1TJ 0.3M
E2E-X10MC312-M1TJ 0.3M
E2E-X10MC1L12-M1TJ 0.3M
E2E-X10MC2L12-M1TJ 0.3M
E2E-X10MC3L12-M1TJ 0.3M
E2E-X10MC112-M1
E2E-X10MC212-M1
E2E-X10MC312-M1
E2E-X10MC1L12-M1
E2E-X10MC2L12-M1
E2E-X10MC3L12-M1
E2E-X20MC1L18 2M
E2E-X20MC2L18 2M
E2E-X20MC3L18 2M
E2E-X20MC1L18-M1TJ 0.3M
47 mm
*2
NC
-
NO+NC
NO
-
E2E-X10MB3D12 2M
E2E-X10MB1DL12 2M
E2E-X10MB2L12 2M
E2E-X10MB3DL12 2M
E2E-X10MB1D12-M1TJ 0.3M
E2E-X10MB212-M1TJ 0.3M
E2E-X10MB3D12-M1TJ 0.3M
E2E-X10MB1DL12-M1TJ 0.3M
E2E-X10MB2L12-M1TJ 0.3M
E2E-X10MB3DL12-M1TJ 0.3M
E2E-X10MB1D12-M1
E2E-X10MB212-M1
Pre-wired (2 m) *1
E2E-X10MB1TL12 2M
69 mm
NC
-
-
NO+NC
NO
E2E-X10MB1T12-M1TJ 0.3M
47 mm
*3
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M12
(10 mm)
E2E-X10MB1TL12-M1TJ 0.3M
69 mm
48 mm
70 mm
NC
-
NO+NC
NO
-
E2E-X10MB1T12-M1
NC
-
NO+NC
NO
-
E2E-X10MB3D12-M1
E2E-X10MB1DL12-M1
E2E-X10MB2L12-M1
E2E-X10MB3DL12-M1
E2E-X20MB1DL18 2M
E2E-X20MB2L18 2M
E2E-X20MB3DL18 2M
E2E-X20MB1DL18-M1TJ
M12 Connector
E2E-X10MB1TL12-M1
NC
-
NO+NC
NO
-
E2E-X20MB1TL18 2M
77 mm
*2
Pre-wired (2 m) *1
NC
-
NO+NC
NO
-
E2E-X20MB1TL18-M1TJ
M12 Pre-wired
Smartclick
Connector (0.3 m)
M18
(20 mm)
77 mm
*3
NC
NO+NC
NO
-
E2E-X20MB2L18-M1TJ 0.3M
E2E-X20MB3DL18-M1TJ 0.3M
E2E-X20MB1DL18-M1
E2E-X20MC2L18-M1TJ 0.3M
E2E-X20MC3L18-M1TJ 0.3M
E2E-X20MC1L18-M1
-
E2E-X20MB1TL18-M1
M12 Connector
75 mm
NC
-
-
E2E-X20MB2L18-M1
E2E-X20MC2L18-M1
NO+NC
E2E-X20MB3DL18-M1
E2E-X20MC3L18-M1
22
E2E/E2EQ NEXT Series
PREMIUM Model
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X40MB1DL30 2M
E2E-X40MB2L30 2M
--- *4
NO
NC
E2E-X40MB1TL30 2M
E2E-X40MC1L30 2M
E2E-X40MC2L30 2M
E2E-X40MC3L30 2M
E2E-X40MC1L30-M1TJ 0.3M
E2E-X40MC2L30-M1TJ 0.3M
E2E-X40MC3L30-M1TJ 0.3M
E2E-X40MC1L30-M1
E2E-X40MC2L30-M1
E2E-X40MC3L30-M1
82 mm
*2
Pre-wired (2 m) *1
-
-
NO+NC
NO
E2E-X40MB3DL30 2M
E2E-X40MB1DL30-M1TJ 0.3M
E2E-X40MB2L30-M1TJ 0.3M
E2E-X40MB3DL30-M1TJ 0.3M
E2E-X40MB1DL30-M1
E2E-X40MB2L30-M1
E2E-X40MB1TL30-M1TJ 0.3M
M12 Pre-wired
Smartclick
Connector (0.3 m)
M30
(40 mm)
82 mm
*3
NC
-
NO+NC
NO
-
E2E-X40MB1TL30-M1
M12 Connector
80 mm
NC
-
-
NO+NC
E2E-X40MB3DL30-M1
*1. Models with 5-m cable length are also available (Example: E2E-X10MB1D12 5M)
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X10MB1D12-R
2M/E2E-X10MB1D12-R 5M)
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-
X10MB1D12-M1TJR 0.3M)
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
23
E2E/E2EQ NEXT Series
PREMIUM Model
E2EQ NEXT Series (Spatter-resistant Triple distance model)
DC 3-wire [Refer to Dimensions on page 64.]
Shielded *1
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
--- *3
IO-Link (COM3)
IO-Link (COM2) *3
E2EQ-X3B1D8 2M
E2EQ-X3B28 2M
NO
NC
E2EQ-X3B1T8 2M
-
E2EQ-X3C18 2M
E2EQ-X3C28 2M
Pre-wired (2 m) *2 38 mm
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO
NC
E2EQ-X3B1T8-M1TJ 0.3M
-
E2EQ-X3B1D8-M1TJ 0.3M
E2EQ-X3B28-M1TJ 0.3M
E2EQ-X3C18-M1TJ 0.3M
E2EQ-X3C28-M1TJ 0.3M
M8
(3 mm)
38 mm
NO
NC
E2EQ-X3B1T8-M1
E2EQ-X3B1D8-M1
E2EQ-X3C18-M1
M12 Connector
43 mm
-
E2EQ-X3B28-M1
E2EQ-X3C28-M1
NO
E2EQ-X6B1T12 2M
E2EQ-X6B1D12 2M
E2EQ-X6C112 2M
Pre-wired (2 m) *2 47 mm
M12 Pre-wired
NC
-
E2EQ-X6B212 2M
E2EQ-X6C212 2M
NO+NC
NO
-
E2EQ-X6B3D12 2M
E2EQ-X6C312 2M
E2EQ-X6B1T12-M1TJ 0.3M
E2EQ-X6B1D12-M1TJ 0.3M
E2EQ-X6B212-M1TJ 0.3M
E2EQ-X6B3D12-M1TJ 0.3M
E2EQ-X6B1D12-M1
E2EQ-X6C112-M1TJ 0.3M
E2EQ-X6C212-M1TJ 0.3M
E2EQ-X6C312-M1TJ 0.3M
E2EQ-X6C112-M1
M12
(6 mm)
Smartclick
47 mm
NC
-
Connector (0.3 m)
NO+NC
NO
-
E2EQ-X6B1T12-M1
M12 Connector
48 mm
NC
-
E2EQ-X6B212-M1
E2EQ-X6C212-M1
NO+NC
NO
-
E2EQ-X6B3D12-M1
E2EQ-X6C312-M1
E2EQ-X12B1T18 2M
E2EQ-X12B1D18 2M
E2EQ-X12B218 2M
E2EQ-X12C118 2M
Pre-wired (2 m) *2 55 mm
M12 Pre-wired
NC
-
-
E2EQ-X12C218 2M
NO+NC
NO
E2EQ-X12B3D18 2M
E2EQ-X12B1D18-M1TJ 0.3M
E2EQ-X12B218-M1TJ 0.3M
E2EQ-X12B3D18-M1TJ 0.3M
E2EQ-X12B1D18-M1
E2EQ-X12B218-M1
E2EQ-X12C318 2M
E2EQ-X12B1T18-M1TJ 0.3M
E2EQ-X12C118-M1TJ 0.3M
E2EQ-X12C218-M1TJ 0.3M
E2EQ-X12C318-M1TJ 0.3M
E2EQ-X12C118-M1
E2EQ-X12C218-M1
E2EQ-X12C318-M1
E2EQ-X22C130 2M
M18
(12 mm)
Smartclick
55 mm
NC
-
Connector (0.3 m)
NO+NC
NO
-
E2EQ-X12B1T18-M1
M12 Connector
53 mm
NC
-
NO+NC
NO
-
E2EQ-X12B3D18-M1
E2EQ-X22B1D30 2M
E2EQ-X22B230 2M
E2EQ-X22B1T30 2M
Pre-wired (2 m) *2 60 mm
M12 Pre-wired
NC
-
E2EQ-X22C230 2M
NO+NC
NO
-
E2EQ-X22B3D30 2M
E2EQ-X22B1D30-M1TJ 0.3M
E2EQ-X22B230-M1TJ 0.3M
E2EQ-X22B3D30-M1TJ 0.3M
E2EQ-X22B1D30-M1
E2EQ-X22B230-M1
E2EQ-X22C330 2M
E2EQ-X22B1T30-M1TJ 0.3M
E2EQ-X22C130-M1TJ 0.3M
E2EQ-X22C230-M1TJ 0.3M
E2EQ-X22C330-M1TJ 0.3M
E2EQ-X22C130-M1
E2EQ-X22C230-M1
E2EQ-X22C330-M1
M30
(22 mm)
Smartclick
60 mm
NC
-
Connector (0.3 m)
NO+NC
NO
-
E2EQ-X22B1T30-M1
M12 Connector
58 mm
NC
-
-
NO+NC
E2EQ-X22B3D30-M1
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 62.
*2. Models with 5-m cable length are also available (Example: E2EQ-X6B1D12 5M)
*3. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
24
E2E/E2EQ NEXT Series
BASIC Model
E2E NEXT Series (Double distance model)
DC 3-wire [Refer to Dimensions on page 65.]
Shielded
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
E2E-X2B1T8 2M
IO-Link (COM2) *4
E2E-X2B1D8 2M
--- *4
NO
NC
E2E-X2C18 2M
38 mm
*2
-
E2E-X2B28 2M
E2E-X2C28 2M
Pre-wired (2 m) *1
NO
E2E-X2B1TL8 2M
E2E-X2B1DL8 2M
E2E-X2B2L8 2M
E2E-X2C1L8 2M
48 mm
NC
-
E2E-X2C2L8 2M
NO
E2E-X2B1T8-M1TJ 0.3M
E2E-X2B1D8-M1TJ 0.3M
E2E-X2B28-M1TJ 0.3M
E2E-X2B1DL8-M1TJ 0.3M
E2E-X2B2L8-M1TJ 0.3M
E2E-X2B1D8-M1
E2E-X2C18-M1TJ 0.3M
E2E-X2C28-M1TJ 0.3M
E2E-X2C1L8-M1TJ 0.3M
E2E-X2C2L8-M1TJ 0.3M
E2E-X2C18-M1
38 mm
*3
M12 Pre-wired
Smartclick
Connector (0.3 m)
NC
-
NO
E2E-X2B1TL8-M1TJ 0.3M
48 mm
43 mm
NC
-
NO
E2E-X2B1T8-M1
NC
-
E2E-X2B28-M1
E2E-X2C28-M1
M8
(2 mm)
M12 Connector
NO
E2E-X2B1TL8-M1
E2E-X2B1DL8-M1
E2E-X2B2L8-M1
E2E-X2C1L8-M1
53 mm
NC
-
E2E-X2C2L8-M1
NO+NC
NO
-
E2E-X2B3DL8-M1
E2E-X2B1D8-M3
E2E-X2C3L8-M1
E2E-X2B1T8-M3
E2E-X2C18-M3
39 mm
49 mm
39 mm
49 mm
NC
-
E2E-X2B28-M3
E2E-X2C28-M3
M8 Connector
(4-pin)
NO
E2E-X2B1TL8-M3
E2E-X2B1DL8-M3
E2E-X2B2L8-M3
E2E-X2C1L8-M3
NC
-
E2E-X2C2L8-M3
NO
E2E-X2B1T8-M5
E2E-X2B1D8-M5
E2E-X2C18-M5
NC
-
E2E-X2B28-M5
E2E-X2C28-M5
M8 Connector
(3-pin)
NO
E2E-X2B1TL8-M5
E2E-X2B1DL8-M5
E2E-X2B2L8-M5
E2E-X2C1L8-M5
NC
-
E2E-X2C2L8-M5
NO
E2E-X4B1T12 2M
E2E-X4B1D12 2M
E2E-X4B212 2M
E2E-X4C112 2M
47 mm
*2
NC
-
E2E-X4C212 2M
NO+NC
NO
-
E2E-X4B3D12 2M
E2E-X4B1DL12 2M
E2E-X4B2L12 2M
E2E-X4C312 2M
Pre-wired (2 m) *1
E2E-X4B1TL12 2M
E2E-X4C1L12 2M
E2E-X4C2L12 2M
E2E-X4C3L12 2M
E2E-X4C112-M1TJ 0.3M
E2E-X4C212-M1TJ 0.3M
E2E-X4C312-M1TJ 0.3M
E2E-X4C1L12-M1TJ 0.3M
E2E-X4C2L12-M1TJ 0.3M
E2E-X4C3L12-M1TJ 0.3M
E2E-X4C112-M1
69 mm
NC
-
NO+NC
NO
-
E2E-X4B3DL12 2M
E2E-X4B1D12-M1TJ 0.3M
E2E-X4B212-M1TJ 0.3M
E2E-X4B3D12-M1TJ 0.3M
E2E-X4B1DL12-M1TJ 0.3M
E2E-X4B2L12-M1TJ 0.3M
E2E-X4B3DL12-M1TJ 0.3M
E2E-X4B1D12-M1
E2E-X4B212-M1
E2E-X4B1T12-M1TJ 0.3M
47 mm
*3
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M12
(4 mm)
E2E-X4B1TL12-M1TJ 0.3M
69 mm
48 mm
70 mm
NC
-
NO+NC
NO
-
E2E-X4B1T12-M1
NC
-
E2E-X4C212-M1
NO+NC
NO
-
E2E-X4B3D12-M1
E2E-X4B1DL12-M1
E2E-X4B2L12-M1
E2E-X4B3DL12-M1
E2E-X4C312-M1
M12 Connector
E2E-X4B1TL12-M1
E2E-X4C1L12-M1
E2E-X4C2L12-M1
E2E-X4C3L12-M1
NC
-
-
NO+NC
25
E2E/E2EQ NEXT Series
BASIC Model
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X8B1D18 2M
--- *4
NO
NC
E2E-X8B1T18 2M
E2E-X8C118 2M
55 mm
*2
-
E2E-X8B218 2M
E2E-X8C218 2M
NO+NC
NO
-
E2E-X8B3D18 2M
E2E-X8C318 2M
Pre-wired (2 m) *1
E2E-X8B1TL18 2M
E2E-X8B1DL18 2M
E2E-X8C1L18 2M
77 mm
NC
-
E2E-X8B2L18 2M
E2E-X8C2L18 2M
NO+NC
NO
-
E2E-X8B3DL18 2M
E2E-X8C3L18 2M
E2E-X8B1T18-M1TJ 0.3M
E2E-X8B1D18-M1TJ 0.3M
E2E-X8B218-M1TJ 0.3M
E2E-X8B3D18-M1TJ 0.3M
E2E-X8B1DL18-M1TJ 0.3M
E2E-X8B2L18-M1TJ 0.3M
E2E-X8B3DL18-M1TJ 0.3M
E2E-X8B1D18-M1
E2E-X8C118-M1TJ 0.3M
E2E-X8C218-M1TJ 0.3M
E2E-X8C318-M1TJ 0.3M
E2E-X8C1L18-M1TJ 0.3M
E2E-X8C2L18-M1TJ 0.3M
E2E-X8C3L18-M1TJ 0.3M
E2E-X8C118-M1
55 mm
*3
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M18
(8 mm)
E2E-X8B1TL18-M1TJ 0.3M
77 mm
53 mm
75 mm
NC
-
NO+NC
NO
-
E2E-X8B1T18-M1
NC
-
E2E-X8B218-M1
E2E-X8C218-M1
NO+NC
NO
-
E2E-X8B3D18-M1
E2E-X8C318-M1
M12 Connector
E2E-X8B1TL18-M1
E2E-X8B1DL18-M1
E2E-X8C1L18-M1
NC
-
E2E-X8B2L18-M1
E2E-X8C2L18-M1
NO+NC
NO
-
E2E-X8B3DL18-M1
E2E-X8C3L18-M1
E2E-X15B1T30 2M
E2E-X15B1D30 2M
E2E-X15C130 2M
60 mm
*2
NC
-
E2E-X15B230 2M
E2E-X15C230 2M
NO+NC
NO
-
E2E-X15B3D30 2M
E2E-X15C330 2M
Pre-wired (2 m) *1
E2E-X15B1TL30 2M
E2E-X15B1DL30 2M
E2E-X15B2L30 2M
E2E-X15C1L30 2M
E2E-X15C2L30 2M
E2E-X15C3L30 2M
E2E-X15C130-M1TJ 0.3M
E2E-X15C230-M1TJ 0.3M
E2E-X15C330-M1TJ 0.3M
E2E-X15C1L30-M1TJ 0.3M
E2E-X15C2L30-M1TJ 0.3M
E2E-X15C3L30-M1TJ 0.3M
E2E-X15C130-M1
82 mm
NC
-
NO+NC
NO
-
E2E-X15B3DL30 2M
E2E-X15B1D30-M1TJ 0.3M
E2E-X15B230-M1TJ 0.3M
E2E-X15B3D30-M1TJ 0.3M
E2E-X15B1DL30-M1TJ 0.3M
E2E-X15B2L30-M1TJ 0.3M
E2E-X15B3DL30-M1TJ 0.3M
E2E-X15B1D30-M1
E2E-X15B1T30-M1TJ 0.3M
60 mm
*3
NC
-
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
M30
(15 mm)
E2E-X15B1TL30-M1TJ 0.3M
82 mm
58 mm
80 mm
NC
-
NO+NC
NO
-
E2E-X15B1T30-M1
NC
-
E2E-X15B230-M1
E2E-X15C230-M1
NO+NC
NO
-
E2E-X15B3D30-M1
E2E-X15C330-M1
M12 Connector
E2E-X15B1TL30-M1
E2E-X15B1DL30-M1
E2E-X15B2L30-M1
E2E-X15C1L30-M1
E2E-X15C2L30-M1
E2E-X15C3L30-M1
NC
-
-
NO+NC
E2E-X15B3DL30-M1
*1. Models with 5-m cable length are also available (Example: E2E-X2B1D8 5M)
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X2B1D8-R 2M/
E2E-X2B1D8-R 5M)
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-
X4B1T12-M1TJR 0.3M)
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
26
E2E/E2EQ NEXT Series
BASIC Model
E2E NEXT Series (Double distance model)
DC 3-wire [Refer to Dimensions on page 65.]
Unshielded
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X4MB1D8 2M
--- *4
NO
NC
E2E-X4MB1T8 2M
E2E-X4MC18 2M
38 mm
*2
-
E2E-X4MB28 2M
E2E-X4MC28 2M
Pre-wired (2 m) *1
NO
E2E-X4MB1TL8 2M
E2E-X4MB1DL8 2M
E2E-X4MB2L8 2M
E2E-X4MC1L8 2M
48 mm
NC
-
E2E-X4MC2L8 2M
NO
E2E-X4MB1T8-M1TJ 0.3M
E2E-X4MB1D8-M1TJ 0.3M
E2E-X4MB28-M1TJ 0.3M
E2E-X4MB1DL8-M1TJ 0.3M
E2E-X4MB2L8-M1TJ 0.3M
E2E-X4MB1D8-M1
E2E-X4MC18-M1TJ 0.3M
E2E-X4MC28-M1TJ 0.3M
E2E-X4MC1L8-M1TJ 0.3M
E2E-X4MC2L8-M1TJ 0.3M
E2E-X4MC18-M1
38 mm
*3
M12 Pre-wired
Smartclick
Connector (0.3 m)
NC
-
NO
E2E-X4MB1TL8-M1TJ 0.3M
48 mm
43 mm
NC
-
NO
E2E-X4MB1T8-M1
NC
-
E2E-X4MB28-M1
E2E-X4MC28-M1
M8
(4 mm)
M12 Connector
NO
E2E-X4MB1TL8-M1
E2E-X4MB1DL8-M1
E2E-X4MB2L8-M1
E2E-X4MC1L8-M1
E2E-X4MC2L8-M1
E2E-X4MC3L8-M1
E2E-X4MC18-M3
53 mm
NC
-
NO+NC
NO
-
E2E-X4MB3DL8-M1
E2E-X4MB1D8-M3
E2E-X4MB1T8-M3
39 mm
49 mm
39 mm
49 mm
NC
-
E2E-X4MB28-M3
E2E-X4MC28-M3
M8 Connector
(4-pin)
NO
E2E-X4MB1TL8-M3
E2E-X4MB1DL8-M3
E2E-X4MB2L8-M3
E2E-X4MC1L8-M3
E2E-X4MC2L8-M3
E2E-X4MC18-M5
NC
-
NO
E2E-X4MB1T8-M5
E2E-X4MB1D8-M5
NC
-
E2E-X4MB28-M5
E2E-X4MC28-M5
M8 Connector
(3-pin)
NO
E2E-X4MB1TL8-M5
E2E-X4MB1DL8-M5
E2E-X4MB2L8-M5
E2E-X4MC1L8-M5
E2E-X4MC2L8-M5
E2E-X8MC112 2M
NC
-
NO
E2E-X8MB1T12 2M
E2E-X8MB1D12 2M
E2E-X8MB212 2M
47 mm
*2
NC
-
E2E-X8MC212 2M
NO+NC
NO
-
E2E-X8MB3D12 2M
E2E-X8MB1DL12 2M
E2E-X8MB2L12 2M
E2E-X8MB3DL12 2M
E2E-X8MB1D12-M1TJ 0.3M
E2E-X8MB212-M1TJ 0.3M
E2E-X8MB3D12-M1TJ 0.3M
E2E-X8MB1DL12-M1TJ 0.3M
E2E-X8MB2L12-M1TJ 0.3M
E2E-X8MB3DL12-M1TJ 0.3M
E2E-X8MB1D12-M1
E2E-X8MB212-M1
E2E-X8MC312 2M
Pre-wired (2 m) *1
E2E-X8MB1TL12 2M
E2E-X8MC1L12 2M
E2E-X8MC2L12 2M
E2E-X8MC3L12 2M
E2E-X8MC112-M1TJ 0.3M
E2E-X8MC212-M1TJ 0.3M
E2E-X8MC312-M1TJ 0.3M
E2E-X8MC1L12-M1TJ 0.3M
E2E-X8MC2L12-M1TJ 0.3M
E2E-X8MC3L12-M1TJ 0.3M
E2E-X8MC112-M1
69 mm
NC
-
NO+NC
NO
-
E2E-X8MB1T12-M1TJ 0.3M
47 mm
*3
NC
-
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
M12
(8 mm)
E2E-X8MB1TL12-M1TJ 0.3M
69 mm
48 mm
70 mm
NC
-
NO+NC
NO
-
E2E-X8MB1T12-M1
NC
-
E2E-X8MC212-M1
NO+NC
NO
-
E2E-X8MB3D12-M1
E2E-X8MB1DL12-M1
E2E-X8MB2L12-M1
E2E-X8MB3DL12-M1
E2E-X8MC312-M1
M12 Connector
E2E-X8MB1TL12-M1
E2E-X8MC1L12-M1
E2E-X8MC2L12-M1
E2E-X8MC3L12-M1
NC
-
-
NO+NC
27
E2E/E2EQ NEXT Series
BASIC Model
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X16MB1D18 2M
--- *4
NO
NC
E2E-X16MB1T18 2M
E2E-X16MC118 2M
55 mm
*2
-
E2E-X16MB218 2M
E2E-X16MC218 2M
NO+NC
NO
-
E2E-X16MB3D18 2M
E2E-X16MC318 2M
Pre-wired (2 m) *1
E2E-X16MB1TL18 2M
E2E-X16MB1DL18 2M
E2E-X16MB2L18 2M
E2E-X16MC1L18 2M
E2E-X16MC2L18 2M
E2E-X16MC3L18 2M
E2E-X16MC118-M1TJ 0.3M
E2E-X16MC218-M1TJ 0.3M
E2E-X16MC318-M1TJ 0.3M
E2E-X16MC1L18-M1TJ 0.3M
E2E-X16MC2L18-M1TJ 0.3M
E2E-X16MC3L18-M1TJ 0.3M
E2E-X16MC118-M1
77 mm
NC
-
-
NO+NC
NO
E2E-X16MB3DL18 2M
E2E-X16MB1D18-M1TJ 0.3M
E2E-X16MB218-M1TJ 0.3M
E2E-X16MB3D18-M1TJ 0.3M
E2E-X16MB1DL18-M1TJ 0.3M
E2E-X16MB2L18-M1TJ 0.3M
E2E-X16MB3DL18-M1TJ 0.3M
E2E-X16MB1D18-M1
E2E-X16MB1T18-M1TJ 0.3M
55 mm
*3
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M18
(16 mm)
E2E-X16MB1TL18-M1TJ 0.3M
77 mm
53 mm
75 mm
NC
-
NO+NC
NO
-
E2E-X16MB1T18-M1
NC
-
E2E-X16MB218-M1
E2E-X16MC218-M1
NO+NC
NO
-
E2E-X16MB3D18-M1
E2E-X16MC318-M1
M12 Connector
E2E-X16MB1TL18-M1
E2E-X16MB1DL18-M1
E2E-X16MB2L18-M1
E2E-X16MC1L18-M1
E2E-X16MC2L18-M1
E2E-X16MC3L18-M1
E2E-X30MC1L30 2M
E2E-X30MC2L30 2M
E2E-X30MC3L30 2M
E2E-X30MC1L30-M1TJ 0.3M
E2E-X30MC2L30-M1TJ 0.3M
E2E-X30MC3L30-M1TJ 0.3M
E2E-X30MC1L30-M1
E2E-X30MC2L30-M1
E2E-X30MC3L30-M1
NC
-
NO+NC
NO
-
E2E-X16MB3DL18-M1
E2E-X30MB1DL30 2M
E2E-X30MB2L30 2M
E2E-X30MB1TL30 2M
82 mm
*2
Pre-wired (2 m) *1
NC
-
NO+NC
NO
-
E2E-X30MB3DL30 2M
E2E-X30MB1DL30-M1TJ 0.3M
E2E-X30MB2L30-M1TJ 0.3M
E2E-X30MB3DL30-M1TJ 0.3M
E2E-X30MB1DL30-M1
E2E-X30MB2L30-M1
E2E-X30MB1TL30-M1TJ 0.3M
M12 Pre-wired
Smartclick
Connector (0.3 m)
M30
(30 mm)
82 mm
*3
NC
-
NO+NC
NO
-
E2E-X30MB1TL30-M1
M12 Connector
80 mm
NC
-
-
NO+NC
E2E-X30MB3DL30-M1
*1. Models with 5-m cable length are also available (Example: E2E-X8MB1D12 5M)
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X8MB1D12-R 2M/
E2E-X8MB1D12-R 5M)
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-
X8MB1D12-M1TJR 0.3M)
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
28
E2E/E2EQ NEXT Series
BASIC Model
E2E NEXT Series (Single distance model)
DC 3-wire [Refer to Dimensions on page 65.]
Shielded
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X1R5B1D8 2M
E2E-X1R5B28 2M
--- *4
NO
NC
E2E-X1R5B1T8 2M
E2E-X1R5C18 2M
38 mm
*2
-
E2E-X1R5C28 2M
Pre-wired (2 m) *1
NO
E2E-X1R5B1TL8 2M
E2E-X1R5B1DL8 2M
E2E-X1R5B2L8 2M
E2E-X1R5B1D8-M1TJ 0.3M
E2E-X1R5B28-M1TJ 0.3M
E2E-X1R5B1DL8-M1TJ 0.3M
E2E-X1R5B2L8-M1TJ 0.3M
E2E-X1R5B1D8-M1
E2E-X1R5B28-M1
E2E-X1R5C1L8 2M
E2E-X1R5C2L8 2M
E2E-X1R5C18-M1TJ 0.3M
E2E-X1R5C28-M1TJ 0.3M
E2E-X1R5C1L8-M1TJ 0.3M
E2E-X1R5C2L8-M1TJ 0.3M
E2E-X1R5C18-M1
48 mm
NC
-
NO
E2E-X1R5B1T8-M1TJ 0.3M
-
38 mm
*3
M12 Pre-wired
Smartclick
Connector (0.3 m)
NC
NO
E2E-X1R5B1TL8-M1TJ 0.3M
48 mm
43 mm
NC
-
NO
E2E-X1R5B1T8-M1
NC
-
E2E-X1R5C28-M1
M8
(1.5 mm)
M12 Connector
NO
E2E-X1R5B1TL8-M1
E2E-X1R5B1DL8-M1
E2E-X1R5B2L8-M1
E2E-X1R5B3DL8-M1
E2E-X1R5B1D8-M3
E2E-X1R5B28-M3
E2E-X1R5C1L8-M1
E2E-X1R5C2L8-M1
E2E-X1R5C3L8-M1
E2E-X1R5C18-M3
53 mm
NC
-
NO+NC
NO
-
E2E-X1R5B1T8-M3
39 mm
49 mm
39 mm
49 mm
NC
-
E2E-X1R5C28-M3
M8 Connector
(4-pin)
NO
E2E-X1R5B1TL8-M3
E2E-X1R5B1DL8-M3
E2E-X1R5B2L8-M3
E2E-X1R5B1D8-M5
E2E-X1R5B28-M5
E2E-X1R5C1L8-M3
E2E-X1R5C2L8-M3
E2E-X1R5C18-M5
NC
-
NO
E2E-X1R5B1T8-M5
NC
-
E2E-X1R5C28-M5
M8 Connector
(3-pin)
NO
E2E-X1R5B1TL8-M5
E2E-X1R5B1DL8-M5
E2E-X1R5B2L8-M5
E2E-X2B1D12 2M
E2E-X1R5C1L8-M5
E2E-X1R5C2L8-M5
E2E-X2C112 2M
NC
-
NO
E2E-X2B1T12 2M
47 mm
*2
NC
-
E2E-X2B212 2M
E2E-X2C212 2M
NO+NC
NO
-
E2E-X2B3D12 2M
E2E-X2C312 2M
Pre-wired (2 m) *1
E2E-X2B1TL12 2M
E2E-X2B1DL12 2M
E2E-X2B2L12 2M
E2E-X2C1L12 2M
69 mm
NC
-
E2E-X2C2L12 2M
NO+NC
NO
-
E2E-X2B3DL12 2M
E2E-X2B1D12-M1TJ 0.3M
E2E-X2B212-M1TJ 0.3M
E2E-X2B3D12-M1TJ 0.3M
E2E-X2B1DL12-M1TJ 0.3M
E2E-X2B2L12-M1TJ 0.3M
E2E-X2B3DL12-M1TJ 0.3M
E2E-X2B1D12-M1
E2E-X2C3L12 2M
E2E-X2B1T12-M1TJ 0.3M
E2E-X2C112-M1TJ 0.3M
E2E-X2C212-M1TJ 0.3M
E2E-X2C312-M1TJ 0.3M
E2E-X2C1L12-M1TJ 0.3M
E2E-X2C2L12-M1TJ 0.3M
E2E-X2C3L12-M1TJ 0.3M
E2E-X2C112-M1
47 mm
*3
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M12
(2 mm)
E2E-X2B1TL12-M1TJ 0.3M
69 mm
48 mm
70 mm
NC
-
NO+NC
NO
-
E2E-X2B1T12-M1
NC
-
E2E-X2B212-M1
E2E-X2C212-M1
NO+NC
NO
-
E2E-X2B3D12-M1
E2E-X2C312-M1
M12 Connector
E2E-X2B1TL12-M1
E2E-X2B1DL12-M1
E2E-X2B2L12-M1
E2E-X2C1L12-M1
NC
-
-
E2E-X2C2L12-M1
NO+NC
E2E-X2B3DL12-M1
E2E-X2C3L12-M1
29
E2E/E2EQ NEXT Series
BASIC Model
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X5B1D18 2M
--- *4
NO
NC
E2E-X5B1T18 2M
E2E-X5C118 2M
55 mm
*2
-
E2E-X5B218 2M
E2E-X5C218 2M
NO+NC
NO
-
E2E-X5B3D18 2M
E2E-X5C318 2M
Pre-wired (2 m) *1
E2E-X5B1TL18 2M
E2E-X5B1DL18 2M
E2E-X5C1L18 2M
77 mm
NC
-
E2E-X5B2L18 2M
E2E-X5C2L18 2M
NO+NC
NO
-
E2E-X5B3DL18 2M
E2E-X5C3L18 2M
E2E-X5B1T18-M1TJ 0.3M
E2E-X5B1D18-M1TJ 0.3M
E2E-X5B218-M1TJ 0.3M
E2E-X5B3D18-M1TJ 0.3M
E2E-X5B1DL18-M1TJ 0.3M
E2E-X5B2L18-M1TJ 0.3M
E2E-X5B3DL18-M1TJ 0.3M
E2E-X5B1D18-M1
E2E-X5C118-M1TJ 0.3M
E2E-X5C218-M1TJ 0.3M
E2E-X5C318-M1TJ 0.3M
E2E-X5C1L18-M1TJ 0.3M
E2E-X5C2L18-M1TJ 0.3M
E2E-X5C3L18-M1TJ 0.3M
E2E-X5C118-M1
55 mm
*3
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M18
(5 mm)
E2E-X5B1TL18-M1TJ 0.3M
77 mm
53 mm
75 mm
NC
-
NO+NC
NO
-
E2E-X5B1T18-M1
NC
-
E2E-X5B218-M1
E2E-X5C218-M1
NO+NC
NO
-
E2E-X5B3D18-M1
E2E-X5C318-M1
M12 Connector
E2E-X5B1TL18-M1
E2E-X5B1DL18-M1
E2E-X5C1L18-M1
NC
-
E2E-X5B2L18-M1
E2E-X5C2L18-M1
NO+NC
NO
-
E2E-X5B3DL18-M1
E2E-X5C3L18-M1
E2E-X10B1T30 2M
E2E-X10B1D30 2M
E2E-X10C130 2M
60 mm
*2
NC
-
E2E-X10B230 2M
E2E-X10C230 2M
NO+NC
NO
-
E2E-X10B3D30 2M
E2E-X10C330 2M
Pre-wired (2 m) *1
E2E-X10B1TL30 2M
E2E-X10B1DL30 2M
E2E-X10B2L30 2M
E2E-X10C1L30 2M
E2E-X10C2L30 2M
E2E-X10C3L30 2M
E2E-X10C130-M1TJ 0.3M
E2E-X10C230-M1TJ 0.3M
E2E-X10C330-M1TJ 0.3M
E2E-X10C1L30-M1TJ 0.3M
E2E-X10C2L30-M1TJ 0.3M
E2E-X10C3L30-M1TJ 0.3M
E2E-X10C130-M1
82 mm
NC
-
NO+NC
NO
-
E2E-X10B3DL30 2M
E2E-X10B1D30-M1TJ 0.3M
E2E-X10B230-M1TJ 0.3M
E2E-X10B3D30-M1TJ 0.3M
E2E-X10B1DL30-M1TJ 0.3M
E2E-X10B2L30-M1TJ 0.3M
E2E-X10B3DL30-M1TJ 0.3M
E2E-X10B1D30-M1
E2E-X10B1T30-M1TJ 0.3M
60 mm
*3
NC
-
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
M30
(10 mm)
E2E-X10B1TL30-M1TJ 0.3M
82 mm
58 mm
80 mm
NC
-
NO+NC
NO
-
E2E-X10B1T30-M1
NC
-
E2E-X10B230-M1
E2E-X10C230-M1
NO+NC
NO
-
E2E-X10B3D30-M1
E2E-X10C330-M1
M12 Connector
E2E-X10B1TL30-M1
E2E-X10B1DL30-M1
E2E-X10B2L30-M1
E2E-X10C1L30-M1
E2E-X10C2L30-M1
E2E-X10C3L30-M1
NC
-
-
NO+NC
E2E-X10B3DL30-M1
*1. Models with 5-m cable length are also available (Example: E2E-X2B1D12 5M)
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X2B1D12-R 2M/
E2E-X2B1D12-R 5M)
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-
X2B1D12-M1TJR 0.3M)
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
30
E2E/E2EQ NEXT Series
BASIC Model
E2E NEXT Series (Single distance model)
DC 3-wire [Refer to Dimensions on page 65.]
Unshielded
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X2MB1D8 2M
--- *4
NO
NC
E2E-X2MB1T8 2M
E2E-X2MC18 2M
38 mm
*2
-
E2E-X2MB28 2M
E2E-X2MC28 2M
Pre-wired (2 m) *1
NO
E2E-X2MB1TL8 2M
E2E-X2MB1DL8 2M
E2E-X2MB2L8 2M
E2E-X2MC1L8 2M
48 mm
NC
-
E2E-X2MC2L8 2M
NO
E2E-X2MB1T8-M1TJ 0.3M
E2E-X2MB1D8-M1TJ 0.3M
E2E-X2MB28-M1TJ 0.3M
E2E-X2MB1DL8-M1TJ 0.3M
E2E-X2MB2L8-M1TJ 0.3M
E2E-X2MB1D8-M1
E2E-X2MC18-M1TJ 0.3M
E2E-X2MC28-M1TJ 0.3M
E2E-X2MC1L8-M1TJ 0.3M
E2E-X2MC2L8-M1TJ 0.3M
E2E-X2MC18-M1
38 mm
*3
M12 Pre-wired
Smartclick
Connector (0.3 m)
NC
-
NO
E2E-X2MB1TL8-M1TJ 0.3M
48 mm
43 mm
NC
-
NO
E2E-X2MB1T8-M1
NC
-
E2E-X2MB28-M1
E2E-X2MC28-M1
M8
(2mm)
M12 Connector
NO
E2E-X2MB1TL8-M1
E2E-X2MB1DL8-M1
E2E-X2MB2L8-M1
E2E-X2MC1L8-M1
E2E-X2MC2L8-M1
E2E-X2MC3L8-M1
E2E-X2MC18-M3
53 mm
NC
-
NO+NC
NO
-
E2E-X2MB3DL8-M1
E2E-X2MB1D8-M3
E2E-X2MB1T8-M3
39 mm
49 mm
39 mm
49 mm
NC
-
E2E-X2MB28-M3
E2E-X2MC28-M3
M8 Connector
(4-pin)
NO
E2E-X2MB1TL8-M3
E2E-X2MB1DL8-M3
E2E-X2MB2L8-M3
E2E-X2MC1L8-M3
E2E-X2MC2L8-M3
E2E-X2MC18-M5
NC
-
NO
E2E-X2MB1T8-M5
E2E-X2MB1D8-M5
NC
-
E2E-X2MB28-M5
E2E-X2MC28-M5
M8 Connector
(3-pin)
NO
E2E-X2MB1TL8-M5
E2E-X2MB1DL8-M5
E2E-X2MB2L8-M5
E2E-X2MC1L8-M5
E2E-X2MC2L8-M5
E2E-X5MC112 2M
NC
-
NO
E2E-X5MB1T12 2M
E2E-X5MB1D12 2M
E2E-X5MB212 2M
47 mm
*2
NC
-
E2E-X5MC212 2M
NO+NC
NO
-
E2E-X5MB3D12 2M
E2E-X5MB1DL12 2M
E2E-X5MB2L12 2M
E2E-X5MB3DL12 2M
E2E-X5MB1D12-M1TJ 0.3M
E2E-X5MB212-M1TJ 0.3M
E2E-X5MB3D12-M1TJ 0.3M
E2E-X5MB1DL12-M1TJ 0.3M
E2E-X5MB2L12-M1TJ 0.3M
E2E-X5MB3DL12-M1TJ 0.3M
E2E-X5MB1D12-M1
E2E-X5MB212-M1
E2E-X5MC312 2M
Pre-wired (2 m) *1
E2E-X5MB1TL12 2M
E2E-X5MC1L12 2M
E2E-X5MC2L12 2M
E2E-X5MC3L12 2M
E2E-X5MC112-M1TJ 0.3M
E2E-X5MC212-M1TJ 0.3M
E2E-X5MC312-M1TJ 0.3M
E2E-X5MC1L12-M1TJ 0.3M
E2E-X5MC2L12-M1TJ 0.3M
E2E-X5MC3L12-M1TJ 0.3M
E2E-X5MC112-M1
69 mm
NC
-
NO+NC
NO
-
E2E-X5MB1T12-M1TJ 0.3M
47 mm
*3
NC
-
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
M12
(5mm)
E2E-X5MB1TL12-M1TJ 0.3M
69 mm
48 mm
70 mm
NC
-
NO+NC
NO
-
E2E-X5MB1T12-M1
NC
-
E2E-X5MC212-M1
NO+NC
NO
-
E2E-X5MB3D12-M1
E2E-X5MB1DL12-M1
E2E-X5MB2L12-M1
E2E-X5MB3DL12-M1
E2E-X5MC312-M1
M12 Connector
E2E-X5MB1TL12-M1
E2E-X5MC1L12-M1
E2E-X5MC2L12-M1
E2E-X5MC3L12-M1
NC
-
-
NO+NC
31
E2E/E2EQ NEXT Series
BASIC Model
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *4
E2E-X10MB1D18 2M
--- *4
NO
NC
E2E-X10MB1T18 2M
E2E-X10MC118 2M
55 mm
*2
-
E2E-X10MB218 2M
E2E-X10MC218 2M
NO+NC
NO
-
E2E-X10MB3D18 2M
E2E-X10MC318 2M
Pre-wired (2 m) *1
E2E-X10MB1TL18 2M
E2E-X10MB1DL18 2M
E2E-X10MB2L18 2M
E2E-X10MC1L18 2M
E2E-X10MC2L18 2M
E2E-X10MC3L18 2M
E2E-X10MC118-M1TJ 0.3M
E2E-X10MC218-M1TJ 0.3M
E2E-X10MC318-M1TJ 0.3M
E2E-X10MC1L18-M1TJ 0.3M
E2E-X10MC2L18-M1TJ 0.3M
E2E-X10MC3L18-M1TJ 0.3M
E2E-X10MC118-M1
77 mm
NC
-
-
NO+NC
NO
E2E-X10MB3DL18 2M
E2E-X10MB1D18-M1TJ 0.3M
E2E-X10MB218-M1TJ 0.3M
E2E-X10MB3D18-M1TJ 0.3M
E2E-X10MB1DL18-M1TJ 0.3M
E2E-X10MB2L18-M1TJ 0.3M
E2E-X10MB3DL18-M1TJ 0.3M
E2E-X10MB1D18-M1
E2E-X10MB1T18-M1TJ 0.3M
55 mm
*3
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M18
(10mm)
E2E-X10MB1TL18-M1TJ 0.3M
77 mm
53 mm
75 mm
NC
-
NO+NC
NO
-
E2E-X10MB1T18-M1
NC
-
E2E-X10MB218-M1
E2E-X10MC218-M1
NO+NC
NO
-
E2E-X10MB3D18-M1
E2E-X10MC318-M1
M12 Connector
E2E-X10MB1TL18-M1
E2E-X10MB1DL18-M1
E2E-X10MB2L18-M1
E2E-X10MC1L18-M1
E2E-X10MC2L18-M1
E2E-X10MC3L18-M1
E2E-X18MC130 2M
NC
-
NO+NC
NO
-
E2E-X10MB3DL18-M1
E2E-X18MB1D30 2M
E2E-X18MB1T30 2M
60 mm
*2
NC
-
E2E-X18MB230 2M
E2E-X18MC230 2M
NO+NC
NO
-
E2E-X18MB3D30 2M
E2E-X18MC330 2M
Pre-wired (2 m) *1
E2E-X18MB1TL30 2M
E2E-X18MB1DL30 2M
E2E-X18MB2L30 2M
E2E-X18MC1L30 2M
E2E-X18MC2L30 2M
E2E-X18MC3L30 2M
E2E-X18MC130-M1TJ 0.3M
E2E-X18MC230-M1TJ 0.3M
E2E-X18MC330-M1TJ 0.3M
E2E-X18MC1L30-M1TJ 0.3M
E2E-X18MC2L30-M1TJ 0.3M
E2E-X18MC3L30-M1TJ 0.3M
E2E-X18MC130-M1
82 mm
NC
-
NO+NC
NO
-
E2E-X18MB3DL30 2M
E2E-X18MB1D30-M1TJ 0.3M
E2E-X18MB230-M1TJ 0.3M
E2E-X18MB3D30-M1TJ 0.3M
E2E-X18MB1DL30-M1TJ 0.3M
E2E-X18MB2L30-M1TJ 0.3M
E2E-X18MB3DL30-M1TJ 0.3M
E2E-X18MB1D30-M1
E2E-X18MB1T30-M1TJ 0.3M
60 mm
*3
NC
-
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO+NC
NO
-
M30
(18mm)
E2E-X18MB1TL30-M1TJ 0.3M
82 mm
58 mm
80 mm
NC
-
NO+NC
NO
-
E2E-X18MB1T30-M1
NC
-
E2E-X18MB230-M1
E2E-X18MC230-M1
NO+NC
NO
-
E2E-X18MB3D30-M1
E2E-X18MC330-M1
M12 Connector
E2E-X18MB1TL30-M1
E2E-X18MB1DL30-M1
E2E-X18MB2L30-M1
E2E-X18MC1L30-M1
E2E-X18MC2L30-M1
E2E-X18MC3L30-M1
NC
-
-
NO+NC
E2E-X18MB3DL30-M1
*1. Models with 5-m cable length are also available (Example: E2E-X5MB1D12 5M)
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X5MB1D12-R 2M/
E2E-X5MB1D12-R 5M)
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-
X5MB1D12-M1TJR 2M)
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
32
E2E/E2EQ NEXT Series
BASIC Model
E2EQ NEXT Series (Spatter-resistant Double distance model)
DC 3-wire [Refer to Dimensions on page 65.]
Shielded
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
IO-Link (COM3)
IO-Link (COM2) *2
--- *2
E2EQ-X2C18 2M
E2EQ-X2C28 2M
NO
NC
E2EQ-X2B1T8 2M
-
E2EQ-X2B1D8 2M
E2EQ-X2B28 2M
Pre-wired (2 m) *1 38 mm
M12 Pre-wired
NO
NC
E2EQ-X2B1T8-M1TJ 0.3M
-
E2EQ-X2B1D8-M1TJ 0.3M
E2EQ-X2B28-M1TJ 0.3M
E2EQ-X2C18-M1TJ 0.3M
E2EQ-X2C28-M1TJ 0.3M
M8
(2 mm)
Smartclick
38 mm
Connector (0.3 m)
NO
NC
E2EQ-X2B1T8-M1
E2EQ-X2B1D8-M1
E2EQ-X2C18-M1
M12 Connector
43 mm
-
E2EQ-X2B28-M1
E2EQ-X2C28-M1
NO
E2EQ-X4B1T12 2M
E2EQ-X4B1D12 2M
E2EQ-X4C112 2M
Pre-wired (2 m) *1 47 mm
M12 Pre-wired
NC
-
E2EQ-X4B212 2M
E2EQ-X4C212 2M
NO+NC
NO
-
E2EQ-X4B3D12 2M
E2EQ-X4C312 2M
E2EQ-X4B1T12-M1TJ 0.3M
E2EQ-X4B1D12-M1TJ 0.3M
E2EQ-X4B212-M1TJ 0.3M
E2EQ-X4B3D12-M1TJ 0.3M
E2EQ-X4B1D12-M1
E2EQ-X4C112-M1TJ 0.3M
E2EQ-X4C212-M1TJ 0.3M
E2EQ-X4C312-M1TJ 0.3M
E2EQ-X4C112-M1
M12
(4 mm)
Smartclick
47 mm
NC
-
Connector (0.3 m)
NO+NC
NO
-
E2EQ-X4B1T12-M1
M12 Connector
48 mm
NC
-
E2EQ-X4B212-M1
E2EQ-X4C212-M1
NO+NC
NO
-
E2EQ-X4B3D12-M1
E2EQ-X4C312-M1
E2EQ-X8B1T18 2M
E2EQ-X8B1D18 2M
E2EQ-X8C118 2M
Pre-wired (2 m) *1 55 mm
M12 Pre-wired
NC
-
E2EQ-X8B218 2M
E2EQ-X8C218 2M
NO+NC
NO
-
E2EQ-X8B3D18 2M
E2EQ-X8C318 2M
E2EQ-X8B1T18-M1TJ 0.3M
E2EQ-X8B1D18-M1TJ 0.3M
E2EQ-X8B218-M1TJ 0.3M
E2EQ-X8B3D18-M1TJ 0.3M
E2EQ-X8B1D18-M1
E2EQ-X8C118-M1TJ 0.3M
E2EQ-X8C218-M1TJ 0.3M
E2EQ-X8C318-M1TJ 0.3M
E2EQ-X8C118-M1
M18
(8 mm)
Smartclick
55 mm
NC
-
Connector (0.3 m)
NO+NC
NO
-
E2EQ-X8B1T18-M1
M12 Connector
53 mm
NC
-
E2EQ-X8B218-M1
E2EQ-X8C218-M1
NO+NC
NO
-
E2EQ-X8B3D18-M1
E2EQ-X8C318-M1
E2EQ-X15B1T30 2M
E2EQ-X15B1D30 2M
E2EQ-X15B230 2M
E2EQ-X15C130 2M
E2EQ-X15C230 2M
E2EQ-X15C330 2M
E2EQ-X15C130-M1TJ 0.3M
E2EQ-X15C230-M1TJ 0.3M
E2EQ-X15C330-M1TJ 0.3M
E2EQ-X15C130-M1
E2EQ-X15C230-M1
E2EQ-X15C330-M1
Pre-wired (2 m) *1 60 mm
M12 Pre-wired
NC
-
-
NO+NC
NO
E2EQ-X15B3D30 2M
E2EQ-X15B1D30-M1TJ 0.3M
E2EQ-X15B230-M1TJ 0.3M
E2EQ-X15B3D30-M1TJ 0.3M
E2EQ-X15B1D30-M1
E2EQ-X15B230-M1
E2EQ-X15B1T30-M1TJ 0.3M
M30
(15 mm)
Smartclick
60 mm
NC
-
Connector (0.3 m)
NO+NC
NO
-
E2EQ-X15B1T30-M1
M12 Connector
58 mm
NC
-
-
NO+NC
E2EQ-X15B3D30-M1
*1. Models with 5-m cable length are also available (Example: E2EQ-X6B1D12 5M)
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
33
E2E/E2EQ NEXT Series
BASIC Model
E2EQ NEXT Series (Spatter-resistant Single distance model)
DC 3-wire [Refer to Dimensions on page 65.]
Shielded
Model
Size
(Sensing
distance)
Connection
method
Body
size
Operation
mode
PNP
NPN
--- *2
IO-Link (COM3)
IO-Link (COM2) *2
E2EQ-X1R5B1D8 2M
E2EQ-X1R5B28 2M
NO
NC
E2EQ-X1R5B1T8 2M
-
E2EQ-X1R5C18 2M
E2EQ-X1R5C28 2M
Pre-wired (2 m) *1 38 mm
M12 Pre-wired
Smartclick
Connector (0.3 m)
NO
NC
E2EQ-X1R5B1T8-M1TJ 0.3M
-
E2EQ-X1R5B1D8-M1TJ 0.3M
E2EQ-X1R5B28-M1TJ 0.3M
E2EQ-X1R5C18-M1TJ 0.3M
E2EQ-X1R5C28-M1TJ 0.3M
M8
(1.5 mm)
38 mm
NO
NC
E2EQ-X1R5B1T8-M1
E2EQ-X1R5B1D8-M1
E2EQ-X1R5B28-M1
E2EQ-X1R5C18-M1
E2EQ-X1R5C28-M1
E2EQ-X2C112 2M
M12 Connector
43 mm
-
NO
E2EQ-X2B1T12 2M
E2EQ-X2B1D12 2M
Pre-wired (2 m) *1 47 mm
M12 Pre-wired
NC
-
E2EQ-X2B212 2M
E2EQ-X2C212 2M
NO+NC
NO
-
E2EQ-X2B3D12 2M
E2EQ-X2C312 2M
E2EQ-X2B1T12-M1TJ 0.3M
E2EQ-X2B1D12-M1TJ 0.3M
E2EQ-X2B212-M1TJ 0.3M
E2EQ-X2B3D12-M1TJ 0.3M
E2EQ-X2B1D12-M1
E2EQ-X2C112-M1TJ 0.3M
E2EQ-X2C212-M1TJ 0.3M
E2EQ-X2C312-M1TJ 0.3M
E2EQ-X2C112-M1
M12
(2 mm)
Smartclick
47 mm
NC
-
Connector (0.3 m)
NO+NC
NO
-
E2EQ-X2B1T12-M1
M12 Connector
48 mm
NC
-
E2EQ-X2B212-M1
E2EQ-X2C212-M1
NO+NC
NO
-
E2EQ-X2B3D12-M1
E2EQ-X2C312-M1
E2EQ-X5B1T18 2M
E2EQ-X5B1D18 2M
E2EQ-X5C118 2M
Pre-wired (2 m) *1 55 mm
M12 Pre-wired
NC
-
E2EQ-X5B218 2M
E2EQ-X5C218 2M
NO+NC
NO
-
E2EQ-X5B3D18 2M
E2EQ-X5C318 2M
E2EQ-X5B1T18-M1TJ 0.3M
E2EQ-X5B1D18-M1TJ 0.3M
E2EQ-X5B218-M1TJ 0.3M
E2EQ-X5B3D18-M1TJ 0.3M
E2EQ-X5B1D18-M1
E2EQ-X5C118-M1TJ 0.3M
E2EQ-X5C218-M1TJ 0.3M
E2EQ-X5C318-M1TJ 0.3M
E2EQ-X5C118-M1
M18
(5 mm)
Smartclick
55 mm
NC
-
Connector (0.3 m)
NO+NC
NO
-
E2EQ-X5B1T18-M1
M12 Connector
53 mm
NC
-
E2EQ-X5B218-M1
E2EQ-X5C218-M1
NO+NC
NO
-
E2EQ-X5B3D18-M1
E2EQ-X5C318-M1
E2EQ-X10B1T30 2M
E2EQ-X10B1D30 2M
E2EQ-X10B230 2M
E2EQ-X10C130 2M
E2EQ-X10C230 2M
E2EQ-X10C330 2M
E2EQ-X10C130-M1TJ 0.3M
E2EQ-X10C230-M1TJ 0.3M
E2EQ-X10C330-M1TJ 0.3M
E2EQ-X10C130-M1
E2EQ-X10C230-M1
E2EQ-X10C330-M1
Pre-wired (2 m) *1 60 mm
M12 Pre-wired
NC
-
NO+NC
NO
-
E2EQ-X10B3D30 2M
E2EQ-X10B1D30-M1TJ 0.3M
E2EQ-X10B230-M1TJ 0.3M
E2EQ-X10B3D30-M1TJ 0.3M
E2EQ-X10B1D30-M1
E2EQ-X10B230-M1
E2EQ-X10B1T30-M1TJ 0.3M
M30
(10 mm)
Smartclick
60 mm
NC
-
Connector (0.3 m)
NO+NC
NO
-
E2EQ-X10B1T30-M1
M12 Connector
58 mm
NC
-
-
NO+NC
E2EQ-X10B3D30-M1
*1. Models with 5-m cable length are also available (Example: E2EQ-X6B1D12 5M)
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
Note: Operation mode NO can be changed to NC via IO-Link communications.
34
E2E/E2EQ NEXT Series
Accessories (Sold Separately)
Sensor I/O Connectors
(Models for Pre-wired Connectors) A Sensor I/O Connector is not provided with the Sensor. It must be ordered separately
as required.
Round Oil-resistant Connectors XS5 NEXT series
Cable
diameter
(mm)
Cable
specification
Cable connection
direction
Cable
length (m)
Sensor I/O Connector
model number
Applicable Proximity
Sensor model number
Appearance
Type
1
2
XS5F-D421-C80-X
XS5F-D421-D80-X
XS5F-D421-E80-X
XS5F-D421-G80-X
XS5F-D421-J80-X
XS5F-D421-C80-XR
XS5F-D421-D80-XR
XS5F-D421-E80-XR
XS5F-D421-G80-XR
XS5F-D421-J80-XR
XS5W-D421-C81-X
XS5W-D421-D81-X
XS5W-D421-E81-X
XS5W-D421-G81-X
XS5W-D421-J81-X
XS5W-D421-C81-XR
XS5W-D421-D81-XR
XS5W-D421-E81-XR
XS5W-D421-G81-XR
XS5W-D421-J81-XR
Oil-resistant
PVC cable
Sockets on One
Cable End
6 dia.
6 dia.
6 dia.
6 dia.
Straight
Straight
3
5
10
1
M12
Smartclick
Connector Models
2
Oil-resistant
PVC robot cable Cable End
Sockets on One
3
5
Straight type
E2E-X@@@-M1TJ(R)
E2EQ-X@@@-M1TJ
E2E(Q)-X@@@-M1
10
1
2
Oil-resistant
PVC cable
Socket and Plug
on Cable Ends
Straight (Socket)/
Straight (Plug)
3
5
10
1
2
Oil-resistant
PVC robot cable on Cable Ends
Socket and Plug
Straight (Socket)/
Straight (Plug)
3
5
10
Note: For details of the connector, refer to XS5 NEXT Series on page 87.
Round Water-resistant Connectors XS5 series
Cable
diameter
(mm)
Cable
length
(m)
Cable
Specification
Cable Connection
Direction
Sensor I/O Connector
model number
Applicable Proximity
Sensor model number
Appearance
Type
1
2
XS5F-D421-C80-F
XS5F-D421-D80-F
XS5F-D421-E80-F
XS5F-D421-G80-F
XS5F-D421-J80-F
XS5F-D422-C80-F
XS5F-D422-D80-F
XS5F-D422-E80-F
XS5F-D422-G80-F
XS5F-D422-J80-F
XS5W-D421-C81-F
XS5W-D421-D81-F
XS5W-D421-E81-F
XS5W-D421-G81-F
XS5W-D421-J81-F
XS5W-D422-D81-F
XS5W-D422-G81-F
Straight
3
5
10
1
M12
Smartclick
Sockets on One
Cable End
6 dia.
Connector
2
Right-angle
3
Straight type
5
10
1
E2E-X@@@-M1TJ(R)
E2EQ-X@@@-M1TJ
E2E(Q)-X@@@-M1
PVC robot cable
2
Straight (Socket)/
Straight (Plug)
3
5
Right-angle type
10
2
Socket and Plug
on Cable Ends
Right-angle (Socket)/
Right-angle (Plug)
6 dia.
5
2
5
2
5
XS5W-D423-D81-F
XS5W-D423-G81-F
XS5W-D424-D81-F
XS5W-D424-G81-F
Straight (Socket)/
Right-angle (Plug)
Right-angle (Socket)/
Straight (Plug)
Note: For details of the connector, refer to XS5 Series on page 94.
35
E2E/E2EQ NEXT Series
Round Water-resistant Connectors XS3W-M8/XS3F-M8 series
Cable
diameter cablecores
(mm)
No. of
Cable
length
(m)
Applicable
ProximitySensor
model number
Cable
specification
Cable connection
direction
Sensor I/O Connector
model number
Appearance
Type
(Poles)
2
5
XS3F-M8PVC3S2M
XS3F-M8PVC3S5M
XS3F-M8PVC3S10M
XS3F-M8PVC3A2M
XS3F-M8PVC3A5M
XS3F-M8PVC3A10M
XS3F-M8PVC4S2M
XS3F-M8PVC4S5M
XS3F-M8PVC4S10M
XS3F-M8PVC4A2M
XS3F-M8PVC4A5M
XS3F-M8PVC4A10M
XS3W-M8PVC3SS2M
XS3W-M8PVC3SS5M
XS3W-M8PVC3SS10M
XS3W-M8PVC3SA2M
XS3W-M8PVC3SA5M
XS3W-M8PVC3SA10M
XS3W-M8PVC4SS2M
XS3W-M8PVC4SS5M
XS3W-M8PVC4SS10M
XS3W-M8PVC4SA2M
XS3W-M8PVC4SA5M
XS3W-M8PVC4SA10M
Straight
10
2
3
E2E-X@@@-M5
E2E-X@@@-M3
E2E-X@@@-M5
E2E-X@@@-M3
Right-angle
5
10
2
Sockets on One
Cable End
M8 Connector
Straight type
5
Straight
10
2
4
3
4
Right-angle
5
10
2
PVC cable
5 dia.
Straight (Plug)/
Straight (Socket)
Right-angle type
5
10
2
Straight (Plug)/
Right-angle (Socket)
5
10
2
Socket and Plug
on Cable Ends
Straight (Plug)/
Straight (Socket)
5
10
2
Straight (Plug)/
Right-angle (Socket)
5
10
Note: For details of the connector, refer to XS3W-M8/XS3F-M8 Series on page 102.
Sensor I/O Connectors Oil resistance performance of mating combination
E2E NEXT Series
Applicable connector Model
Connecting method
Pre-wired Connector Models
M12 Connector Models
Model
E2E-X@@-M1TJ(R)
E2E-X@@-M1
E2E-X@@-M3
E2E-X@@-M5
XS5 NEXT Series
XS5 Series
XS3W-M8/XS3F-M8 Series
Oil resistant (2 years) *
Water-resistant (IP67)
---
Water-resistant (IP67)
Water-resistant (IP67)
---
M8 Connector (4-pin) Models
M8 Connector (3-pin) Models
---
---
---
---
Water-resistant (IP67)
Water-resistant (IP67)
* Applicable cutting oil type: specified in JIS K 2241:2000
2 years of oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).
Products to be shipped will have around 2 years of oil resistance, but will very depending on the product.
e-jig (Mounting Sleeves) [Refer to Dimensions on page 66.]
A Mounting Bracket is not provided with the Sensor. It must be ordered separately as required.
Only applicable to standard body-sized E2E NEXT Series Sensors.
Appearance
Model
Applicable Sensors
E2E NEXT M8 Shielded Sensors
Y92E-J8S12
Y92E-J12S18
Y92E-J18S30
E2E NEXT M12 Shielded Sensors
E2E NEXT M18 Shielded Sensors
Note: Not applicable for E2E NEXT Series long-body models and E2EQ NEXT Series (spatter-resistant) models.
36
E2E/E2EQ NEXT Series
Ratings and Specifications
PREMIUM Model
E2E NEXT Series (Quadruple/Triple distance model)
DC 3-wire
Shielded
Types
Size
Quadruple distance model
Triple distance model
M8
M12
M18
M30
M8
M12
M18
M30
Item
Model
E2E-X4@8
4 mm±10%
0 to 3 mm
E2E-X9@12
9 mm±10%
0 to 6.8 mm
E2E-X14@18
14 mm±10%
0 to 10.6 mm
E2E-X23@30
23 mm±10%
0 to 17.6 mm
E2E-X3@8
3 mm±10%
0 to 2.4 mm
E2E-X6@12
6 mm±10%
0 to 4.8 mm
E2E-X12@18
12 mm±10%
0 to 9.6 mm
E2E-X22@30
22 mm±10%
0 to 16.8 mm
Sensing distance
Setting distance
Differential travel
Detectable object
15% max. of sensing distance
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)
Iron, Iron, Iron, Iron, Iron,
12 × 12 × 1 mm 27 × 27 × 1 mm 42 × 42 × 1 mm 69 × 69 × 1 mm 9 × 9 × 1 mm
Standard sensing
object
Iron,
Iron,
Iron,
18 × 18 × 1 mm 36 × 36 × 1 mm 66 × 66 × 1 mm
Response frequency
*1
700 Hz
700 Hz
350 Hz
200 Hz
1,000 Hz
800 Hz 500 Hz 200 Hz
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2
1-output models: 16 mA max.,
2-output models: 20 mA max.
Current consumption 1-output models:16 mA max.
Output configuration
B@ Models: PNP open collector, C@ Models: NPN open collector
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed),
2-output models (B3, C3): NO+NC (Normally open,
Normally closed)
Operation mode
(with sensing object
approaching)
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed)
1-outputmodels: 1-output models:
Load
1-output models:
10 to 30 VDC,
10 to 30 VDC, Class 2, 100 mA max.,
current
10 to 30 VDC, Class 2, 50 mA max.
Class 2, 100 mA 2-output models:
max.
10 to 30 VDC, Class 2, 50 mA max.
Control
output
1-outputmodels:
2 V max.
(Load current:
100 mA, Cable
length: 2 m)
1-output models:
2 V max. (Load current: 100 mA, Cable length: 2 m),
2-output models:
Residual
voltage
1-output models:
2 V max. (Load current: 50 mA, Cable length: 2 m)
2 V max. (Load current: 50 mA, Cable length: 2 m)
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)
Indicator *2
Protection circuits
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection
Operating:
-25 to 60°C
Ambient temperature Storage:
Operating/Storage: -25 to 70°C (with no icing or condensation)
range
-25 to 70°C
(with no icing or
condensation)
Ambient humidity
range
Operating/Storage: 35% to 95% (with no condensation)
-15% to 25%
max. of
sensing
Temperature
influence
distance at
23°C in the
temperature
range of -25 to
60°C
±15% max. of sensing distance at 23°C in the
temperature range of -25 to 70°C
±10% max. of sensing distance at 23°C in the temperature range of
-25 to 70°C
Voltage influence
Insulation resistance
Dielectric strength
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10
times each in
X, Y, and Z
directions
500 m/s2 10
times each in
X, Y, and Z
directions
Shock resistance
(destruction)
1,000 m/s2 10 times each in X, Y, and Z directions
1,000 m/s2 10 times each in X, Y, and Z directions
Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex
1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature:
35°C max.)
Degree of protection
Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12
Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)
Connection method
Pre-wired
Approx. 85 g
Approx. 95 g
Approx. 180 g Approx. 260 g Approx. 85 g
Approx. 95 g
Approx. 180 g Approx. 260 g
M12
Weight*4
Pre-wired
(packed
Approx. 55 g
Approx. 70 g
Approx. 115 g Approx. 200 g Approx. 55 g
Approx. 70 g
Approx. 115 g Approx. 200 g
Smartclick
state)
Connector
Connector Approx. 40 g *5 Approx. 55 g
Approx. 95 g
Approx. 180 g Approx. 40 g *5 Approx. 55 g
Approx. 95 g
Approx. 180 g
37
E2E/E2EQ NEXT Series
Types
Size
Quadruple distance model
Triple distance model
M8
M12
M18
M30
M8
M12
M18
M30
Item
Model
E2E-X4@8
E2E-X9@12
E2E-X14@18
E2E-X23@30
E2E-X3@8
E2E-X6@12
E2E-X12@18
E2E-X22@30
Case
Nickel-plated brass
Sensing
surface
Polybutylene terephthalat (PBT)
Nickel-plated brass
Clamping
nuts
Materials
Toothed
washers
Zinc-plated iron
Cable
Vinyl chloride (PVC)
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating
hours read-out, readout of the sensor internal temperature, and initial reset
Main IO-Link
functions*2
IO-Link
specificati Ver 1.1
on
IO-Link
Commun
ication
specifica
tions *2
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)
Data
length
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)
Minimum
cycle time
COM2: 2.3 ms, COM3: 0.4 ms
Accessories
Instruction manual, Clamping nuts, Toothed washer
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
*3. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards.
2-year oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).
The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round Oil-resistant Connectors XS5 NEXT series correctly.
The degree of protection is not satisfied with the part where cable wires are uncovered for the Pre-wired Models.
*4. Weight of the standard body-sized model.
*5. Both M8 connectors and M12 connectors are available.
38
E2E/E2EQ NEXT Series
PREMIUM Model
E2E NEXT Series (Quadruple/Triple distance model)
DC 3-wire
Unshielded
Types
Size
Quadruple distance model
M12 M18
E2E-X16M@12 E2E-X30M@18 E2E-X50M@30
Triple distance model
M8
M30
M8
M12
M18
M30
Item
Model E2E-X8M@8
E2E-X6M@8
6 mm±10%
0 to 4.8 mm
E2E-X10M@12 E2E-X20M@18 E2E-X40M@30
Sensing distance
Setting distance
Differential travel
Detectable object
8 mm±10%
0 to 6 mm
16 mm±10%
0 to 12.2 mm
30 mm±10%
0 to 23 mm
50 mm±10%
0 to 38.2 mm
10 mm±10%
0 to 8 mm
20 mm±10%
0 to 16 mm
40 mm±10%
0 to 32 mm
15% max. of sensing distance
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)
Iron, Iron, Iron, Iron, Iron,
Standard sensing
object
Iron,
Iron,
Iron,
24 × 24 × 1 mm 48 × 48 × 1 mm 90 × 90 × 1 mm 150 × 150 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm 60 × 60 × 1 mm 120 × 120 × 1 mm
Response frequency
*1
500 Hz 400 Hz 200 Hz 100 Hz 800 Hz 400 Hz 200 Hz 100 Hz
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2
1-output models: 16 mA max.,
2-output models: 20 mA max.
Current consumption 1-output models: 16 mA max.
B@ Models: PNP open collector
Output configuration
C@ Models: NPN open collector
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed),
2-output models (B3, C3):
Operation mode
1-output models (B1, C1): NO (Normally open),
(with sensing object
1-output models (B2, C2): NC (Normally closed)
approaching)
NO+NC (Normally open, Normally closed)
1-outputmodels: 1-output models:
Load
1-output models:
10 to 30 VDC,
10 to 30 VDC, Class 2, 100 mA max.,
current
10 to 30 VDC, Class 2, 50 mA max.
Class 2, 100 mA 2-output models:
max.
10 to 30 VDC, Class 2, 50 mA max.
Control
output
1-outputmodels:
2 V max.
(Load current:
100 mA, Cable
length: 2 m)
1-output models:
2 V max. (Load current: 100 mA, Cable length: 2 m),
2-output models:
Residual
voltage
1-output models:
2 V max. (Load current: 50 mA, Cable length: 2 m)
2 V max. (Load current: 50 mA, Cable length: 2 m)
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)
Indicator *2
Protection circuits
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection
Ambient temperature
range
Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity
range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance at 23°C in the temperature range of ±10% max. of sensing distance at 23°C in the temperature range of
-25 to 70°C
-25 to 70°C
Voltage influence
Insulation resistance
Dielectric strength
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10
times each in
X, Y, and Z
directions
500 m/s2 10
times each in
X, Y, and Z
directions
Shock resistance
(destruction)
1,000 m/s2 10 times each in X, Y, and Z directions
1,000 m/s2 10 times each in X, Y, and Z directions
Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex
1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature:
35°C max.)
Degree of protection
Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12
Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)
Connection method
Pre-wired
Approx. 85 g
Approx. 95 g
Approx. 190 g Approx. 310 g Approx. 85 g
Approx. 95 g
Approx. 190 g Approx. 280 g
Approx. 125 g Approx. 220 g
Approx. 105 g Approx. 200 g
M12
Weight*4
Pre-wired
(packed
Approx. 55 g
Approx. 70 g
Approx. 125 g Approx. 250 g Approx. 55 g
Approx. 70 g
Smartclick
state)
Connector
Connector Approx. 40 g *5 Approx. 55 g
Approx. 105 g Approx. 230 g Approx. 40 g *5 Approx. 55 g
39
E2E/E2EQ NEXT Series
Types
Size
Quadruple distance model
M12 M18
Triple distance model
M12 M18
M8
M30
M8
M30
Item
Model E2E-X8M@8
E2E-X16M@12 E2E-X30M@18 E2E-X50M@30
E2E-X6M@8
E2E-X10M@12 E2E-X20M@18 E2E-X40M@30
Stainless
(SUS303)
Stainless
(SUS303)
Case
Nickel-plated brass
Nickel-plated brass
Sensing
surface
Polybutylene terephthalat (PBT)
Materials Clamping
nuts
Nickel-plated brass
Toothed
washers
Zinc-plated iron
Cable
Vinyl chloride (PVC)
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating
hours read-out, readout of the sensor internal temperature, and initial reset
Main IO-Link
functions*2
IO-Link
specificati Ver1.1
on
IO-Link
Commun
ication
specifica
tions *2
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)
Data
length
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)
Minimum
cycle time
COM2: 2.3 ms, COM3: 0.4 ms
Accessories
Instruction manual, Clamping nuts, Toothed washer
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
*3. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards. 2-year oil resistance indicates the
median value of the product design and the oil-resistance performance criterion result (=Typical value). Actual performance can be expected
to decline after two years on average from shipment. The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round
Oil-resistant Connectors XS5 NEXT series correctly. The degree of protection is not satisfied with the part where cable wires are uncovered
for the Pre-wired Models.
*4. Weight of the standard body-sized model.
*5. Both M8 connectors and M12 connectors are available.
40
E2E/E2EQ NEXT Series
PREMIUM Model
E2EQ NEXT Series (Spatter-resistant Triple distance model)
DC 3-wire
Shielded
Types
Triple distance Models
Size
M8
M12
E2EQ-X6@12
6 mm±10%
0 to 4.8 mm
M18
E2EQ-X12@18
12 mm±10%
0 to 9.6 mm
M30
Item
Model
E2EQ-X3@8
E2EQ-X22@30
Sensing distance
Setting distance
Differential travel
Detectable object
3 mm±10%
22 mm±10%
0 to 2.4 mm
0 to 16.8 mm
15% max. of sensing distance
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)
Standard sensing object
Response frequency *1
Power supply voltage
Iron, 9 × 9 × 1 mm
1,000 Hz
Iron, 18 × 18 × 1 mm
800 Hz
Iron, 36 × 36 × 1 mm
500 Hz
Iron, 66 × 66 × 1 mm
200 Hz
10 to 30 VDC (including 10% ripple (p-p)), Class 2
1-output models: 16 mA max.
2-output models: 20 mA max.
Current consumption
Output configuration
1-output models: 16 mA max.
B@ Models: PNP open collector, C@ Models: NPN open collector
1-output models (B1, C1): NO
(Normally open),
1-output models (B2, C2): NC
(Normally closed)
Operation mode
(with sensing object
approaching)
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed),
2-output models (B3, C3): NO+NC (Normally open, Normally closed)
1-output models: 10 to 30 VDC, 1-output models: 10 to 30 VDC, Class 2, 100 mA max.,,
Load current
Control
Class 2, 100 mA max.
2-output models: 10 to 30 VDC, Class 2, 50 mA max.
1-output models: 2 V max.
(Load current: 100 mA,
Cable length: 2 m)
output
Residual
voltage
1-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m),
2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m)
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s
intervals)
Indicator *2
Protection circuits
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection
Ambient temperature range Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range
Temperature influence
Voltage influence
Operating/Storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Insulation resistance
Dielectric strength
Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10 times each in X, Y,
and Z directions
Shock resistance (destruction)
1,000 m/s2 10 times each in X, Y, and Z directions
Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, JIS C 0920 Annex 1: IP67G
Connector Models: IEC 60529: IP67
Degree of protection
Connection method
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m), M12 Connector Models
Pre-wired
Models
Approx. 85 g
Approx. 95 g
Approx. 180 g
Approx. 260 g
Weight *3
M12 Pre-wired
(packed
Smartclick
state)
Approx. 55 g
Approx. 40 g
Approx. 70 g
Approx. 55 g
Approx. 115 g
Approx. 95 g
Approx. 200 g
Approx. 180 g
Connector
Connector
Case
Fluororesin coating (Base material: brass)
Sensing surface Fluorine resin
Clamping nuts Fluororesin coating (Base material: brass)
Materials
Toothed
Zinc-plated iron
washers
Cable
Vinyl chloride (PVC)
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer
function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor
output, operating hours read-out, readout of the sensor internal temperature, and initial reset
Main IO-Link functions *2
IO-Link
Ver 1.1
specification
IO-Link
Communic
ation
specificati
ons *2
Baud rate
COM2 (38.4 kbps), COM3 (230.4 kbps)
Data length
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)
Minimum cycle
time
COM2: 2.3 ms, COM3: 0.4 ms
Accessories
Instruction manual, Clamping nuts, Toothed washer
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
*3. Weight of the standard body-sized model.
41
E2E/E2EQ NEXT Series
BASIC Model
E2E NEXT Series (Double/Single distance model)
DC 3-wire
Shielded
Types
Size
Double distance
Single distance
M8
M12
M18
M30
M8
M12
M18
M30
Item
Model
E2E-X2@8
E2E-X4@12
4 mm±10%
0 to 3.2 mm
E2E-X8@18
8 mm±10%
0 to 6.4 mm
E2E-X15@30
15 mm±10%
0 to 12 mm
E2E-X1R5@8
1.5 mm±10%
0 to 1.2 mm
E2E-X2@12
2 mm±10%
0 to 1.6 mm
E2E-X5@18
5 mm±10%
0 to 4 mm
E2E-X10@30
10 mm±10%
0 to 8 mm
Sensing distance
Setting distance
Differential travel
Detectable object
2 mm±10%
0 to 1.6 mm
15% max. of sensing distance
10% max. of sensing distance
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)
Standard sensing
object
Iron,
8 × 8 × 1 mm
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
12 × 12 × 1 mm 24 × 24 × 1 mm 45 × 45 × 1 mm 8 × 8 × 1 mm
12 × 12 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm
Response frequency
*1
1,500 Hz
1,000 Hz
500 Hz
250 Hz
2,000 Hz
1,500 Hz
600 Hz
400 Hz
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2
1-output models: 16 mA max.
Current consumption
2-output models: 20 mA max.
B@ Models: PNP open collector
Output configuration
C@ Models: NPN open collector
Operation mode
(with sensing object
approaching)
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed),
2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3
1-output models:
10 to 30 VDC,
Class 2, 200 mA
max., (-40 to
1-output models:
10 to 30 VDC,
Class 2, 200 mA
max., (-40 to
1-output models:
10 to 30 VDC, Class 2, 200 mA max.,
1-output models:
10 to 30 VDC, Class 2, 200 mA max.,
Load
70°C), 100 mA
70°C), 100 mA
current
max., (70 to 85°C) 2-output models:
2-output models: 10 to 30 VDC, Class 2, 100 mA max.
max., (70 to 85°C) 2-output models:
2-output models: 10 to 30 VDC, Class 2, 100 mA max.
10 to 30 VDC,
Class 2, 50 mA
max.
10 to 30 VDC,
Class 2, 50 mA
max.
Control
output
1-output models:
2 V max. (Load
current: 200 mA,
1-output models:
2 V max. (Load
1-output models:
1-output models:
2 V max. (Load current: 200 mA, Cable length: 2
2 V max. (Load current: 200 mA, Cable length: 2 current: 200 mA,
Residual
voltage
Cablelength:2m), m),
2-output models: 2-output models:
Cablelength:2m), m),
2-output models: 2-output models:
2 V max. (Load current: 100 mA, Cable length: 2
m)
2 V max. (Load
current: 50 mA,
Cable length: 2 m)
2 V max. (Load current: 100 mA, Cable length: 2 2 V max. (Load
m)
current: 50 mA,
Cable length: 2 m)
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)
Indicator *2
Protection circuits
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection
Ambient temperature Operating/Storage: -40 to 85°C (with no icing or condensation)
range
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C.
Ambient humidity
range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence
Insulation resistance
Dielectric strength
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10 times
each in X, Y, and
Z directions
500 m/s2 10 times
each in X, Y, and
Z directions
Shock resistance
(destruction)
1,000 m/s2 10 times each in X, Y, and Z
directions
1,000 m/s2 10 times each in X, Y, and Z
directions
Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex
1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature:
35°C max.)
Degree of protection
Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector
Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)
Connection method
Pre-wired
Approx. 85 g
Approx. 95 g
Approx. 70 g
Approx. 55 g
Approx. 170 g Approx. 240 g Approx. 85 g
Approx. 95 g
Approx. 70 g
Approx. 55 g
Approx. 170 g Approx. 240 g
M12
Weight *5
Pre-wired
(packed
Approx. 55 g
Approx. 105 g Approx. 170 g Approx. 55 g
Approx. 105 g Approx. 170 g
Smartclick
state)
Connector
Connector Approx. 40 g *6
Approx. 85 g
Approx. 160 g Approx. 40 g *6
Approx. 85 g
Approx. 160 g
42
E2E/E2EQ NEXT Series
Types
Size
Double distance
Single distance
M8
M12
M18
E2E-X8@18
M30
M8
M12
M18
M30
Item
Model
E2E-X2@8
E2E-X4@12
E2E-X15@30
E2E-X1R5@8
E2E-X2@12
E2E-X5@18
E2E-X10@30
Stainless
(SUS303)
Stainless
(SUS303)
Case
Nickel-plated brass
Nickel-plated brass
Sensing
surface
Polybutylene terephthalat (PBT)
Nickel-plated brass
Materials Clamping
nuts
Toothed
washers
Zinc-plated iron
Cable
Vinyl chloride (PVC)
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating
hours read-out, readout of the sensor internal temperature, and initial reset
Main IO-Link
functions *2
IO-Link
specification
Ver1.1
IO-Link
Commun
ication
specifica
tions *2
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)
Data
length
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)
Minimum
cycle time
COM2: 2.3 ms, COM3: 0.4 ms
Accessories
Instruction manual, Clamping nuts, Toothed washer
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
*3. Dual-output specification for the M8-size models is only applicable to long-size M12 Connector models.
*4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards. 2-year oil resistance indicates the
median value of the product design and the oil-resistance performance criterion result (=Typical value). Actual performance can be expected
to decline after two years on average from shipment. The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round
Oil-resistant Connectors XS5 NEXT series correctly. The degree of protection is not satisfied with the part where cable wires are uncovered
for the Pre-wired Models.
*5. Weight of the standard body-sized model.
*6. Both M8 connectors and M12 connectors are available.
43
E2E/E2EQ NEXT Series
BASIC Model
E2E NEXT Series (Double/Single distance model)
DC 3-wire
Unshielded
Types
Size
Double distance model
M12 M18
E2E-X8M@12 E2E-X16M
Single distance model
M12 M18
E2E-X5M@12 E2E-X10M
M8
E2E-X4M@8
4 mm±10%
0 to 3.2 mm
M30
M8
E2E-X2M@8
2 mm±10%
0 to 1.6 mm
M30
Item
Model
@
18 E2E-X30M
@30
@
18 E2E-X18M@30
Sensing distance
Setting distance
Differential travel
Detectable object
8 mm±10%
0 to 6.4 mm
16 mm±10%
30 mm±10%
5 mm±10%
0 to 4 mm
10 mm±10%
18 mm±10%
0 to 14.4 mm
0 to 12.8 mm 0 to 24 mm
0 to 8 mm
15% max. of sensing distance
10% max. of sensing distance
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)
Standard sensing
object
Iron,
12 × 12 × 1 mm
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
24 × 24 × 1 mm 48 × 48 × 1 mm 90 × 90 × 1 mm 8 × 8 × 1 mm
15 × 15 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm
Response frequency
*1
1,000 Hz
800 Hz
400 Hz
100 Hz
1,000 Hz
800 Hz
400 Hz
100 Hz
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2
1-output models: 16 mA max.
Current consumption
2-output models: 20 mA max.
B@ Models: PNP open collector
Output configuration
C@ Models: NPN open collector
Operation mode
(with sensing object
approaching)
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C3): NC (Normally closed)
2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3
1-output models:
10 to 30 VDC,
Class 2, 200 mA
max., (-40 to
1-output models:
10 to 30 VDC,
Class 2, 200 mA
max., (-40 to
1-output models:
10 to 30 VDC, Class 2, 200 mA max.,
1-output models:
10 to 30 VDC, Class 2, 200 mA max.,
Load
70°C), 100 mA
70°C), 100 mA
current
max., (70 to 85°C) 2-output models:
2-output models: 10 to 30 VDC, Class 2, 100 mA max.
max., (70 to 85°C) 2-output models:
2-output models: 10 to 30 VDC, Class 2, 100 mA max.
10 to 30 VDC,
Class 2, 50 mA
max.
10 to 30 VDC,
Class 2, 50 mA
max.
Control
output
1-output models:
2 V max. (Load
current: 200 mA,
1-output models:
2 V max. (Load
1-output models:
1-output models:
2 V max. (under load current of 200 mA with
2 V max. (Load current: 200 mA, Cable length: 2 current: 200 mA,
Residual
voltage
Cablelength:2m), m),
2-output models: 2-output models:
Cablelength:2m), cable length of 2 m),
2-output models: 2-output models:
2 V max. (under load current of 100 mA with
cable length of 2 m)
2 V max. (Load
current: 50 mA,
Cable length: 2 m)
2 V max. (Load current: 100 mA, Cable length: 2 2 V max. (Load
m)
current: 50 mA,
Cable length: 2 m)
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)
Indicator *2
Protection circuits
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection
Ambient temperature Operating/Storage: -40 to 85°C (with no icing or condensation)
range
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C.
Ambient humidity
range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence
Insulation resistance
Dielectric strength
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10 times
each in X, Y, and
Z directions
500 m/s2 10 times
each in X, Y, and
Z directions
Shock resistance
(destruction)
1,000 m/s2 10 times each in X, Y, and Z
directions
1,000 m/s2 10 times each in X, Y, and Z
directions
Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex
1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature:
35°C max.)
Degree of protection
Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Models (M12 Connector,
M8 (4-pin) Connector and M8 (3-pin) Connector)
Connection method
Pre-wired
Approx. 85 g
Approx. 95 g
Approx. 70 g
Approx. 55 g
Approx. 170 g Approx. 280 g Approx. 85 g
Approx. 95 g
Approx. 70 g
Approx. 55 g
Approx. 170 g Approx. 240 g
M12
Weight *5
Pre-wired
(packed
Approx. 55 g
Approx. 105 g Approx. 220 g Approx. 55 g
Approx. 105 g Approx. 170 g
Smartclick
state)
Connector
Connector Approx. 40 g *6
Approx. 85 g
Approx. 200 g Approx. 40 g *6
Approx. 85 g
Approx. 160 g
44
E2E/E2EQ NEXT Series
Types
Size
Double distance model
M12 M18
Single distance model
M8
M30
M8
M12
M18
M30
Item
Model
E2E-X4M@8
E2E-X8M@12 E2E-X16M@18 E2E-X30M@30
E2E-X2M@8
E2E-X5M@12 E2E-X10M@18 E2E-X18M@30
Stainless
(SUS303)
Stainless
(SUS303)
Case
Nickel-plated brass
Nickel-plated brass
Sensing
surface
Polybutylene terephthalat (PBT)
Nickel-plated brass
Materials Clamping
nuts
Toothed
washers
Zinc-plated iron
Cable
Vinyl chloride (PVC)
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating
hours read-out, readout of the sensor internal temperature, and initial reset
Main IO-Link
functions *2
IO-Link
specificati Ver 1.1
on
IO-Link
Commun
ication
specifica
tions *2
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)
Data
length
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)
Minimum
cycle time
COM2: 2.3 ms, COM3: 0.4 ms
Accessories
Instruction manual, Clamping nuts, Toothed washer
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
*3. Dual-output specification for the M8-size models is only applicable to long-size M12 Connector models.
*4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards. 2-year oil resistance indicates the
median value of the product design and the oil-resistance performance criterion result (=Typical value). Actual performance can be expected
to decline after two years on average from shipment. The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round
Oil-resistant Connectors XS5 NEXT series correctly. The degree of protection is not satisfied with the part where cable wires are uncovered
for the Pre-wired Models.
*5. Weight of the standard body-sized model.
*6. Both M8 connectors and M12 connectors are available.
45
E2E/E2EQ NEXT Series
BASIC Model
E2E Q NEXT Series (Spatter-resistant Double distance/Single distance model)
DC 3-Wire Models
Shielded
Types
Size
Double distance
M12 M18
E2EQ-X4@12 E2EQ-X8@18 E2EQ-X15
Single distance
M12 M18
E2EQ-X2@12 E2EQ-X5@18 E2EQ-X10
M8
E2EQ-X2@8
2 mm±10%
0 to 1.6 mm
M30
M8
M30
Item
Model
@
30
15 mm±10%
0 to 12 mm
E2EQ-X1R5@8
1.5 mm±10%
0 to 1.2 mm
@30
Sensing distance
Setting distance
Differential travel
Detectable object
4 mm±10%
0 to 3.2 mm
8 mm±10%
0 to 6.4 mm
2 mm±10%
0 to 1.6 mm
5 mm±10%
0 to 4 mm
10 mm±10%
0 to 8 mm
15% max. of sensing distance
10% max. of sensing distance
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)
Standard sensing
object
Iron,
8 × 8 × 1 mm
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
12 × 12 × 1 mm 24 × 24 × 1 mm 45 × 45 × 1 mm 8 × 8 × 1 mm
12 × 12 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm
Response frequency
*1
1,500 Hz
1,000 Hz
500 Hz
250 Hz
2,000 Hz
1,500 Hz
600 Hz
400 Hz
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2
1-output models: 16 mA max.
Current consumption
2-output models: 20 mA max.
B@ Models: PNP open collector,
Output configuration
C@ Models: NPN open collector
Operation mode
(with sensing object
approaching)
1-output models (B1, C1): NO (Normally open),
1-output models (B2, C2): NC (Normally closed)
2-output models (B3, C3): NO+NC (Normally open, Normally closed)
1-output models:
10 to 30 VDC,
Class 2, 200 mA
1-output models:
10 to 30 VDC,
Class 2, 200 mA
max., (-40 to
max., (-40 to
1-output models:
1-output models:
10 to 30 VDC, Class 2, 200 mA max.,
Load
70°C), 100 mA
10 to 30 VDC, Class 2, 200 mA max.,
70°C), 100 mA
current
max., (70 to 85°C) 2-output models:
2-output models: 10 to 30 VDC, Class 2, 100 mA max.
max., (70 to 85°C) 2-output models:
2-output models: 10 to 30 VDC, Class 2, 100 mA max.
10 to 30 VDC,
Class 2, 50 mA
max.
10 to 30 VDC,
Class 2, 50 mA
max.
Control
output
1-output models:
2 V max. (Load
current: 200 mA,
1-output models:
2 V max. (Load
1-output models:
1-output models:
2 V max. (Load current: 200 mA, Cable length: 2
2 V max. (Load current: 200 mA, Cable length: 2 current: 200 mA,
Residual
voltage
Cablelength:2m), m),
2-output models: 2-output models:
Cablelength:2m), m),
2-output models: 2-output models:
2 V max. (Load current: 100 mA, Cable length: 2
m)
2 V max. (Load
current: 50 mA,
Cable length: 2 m)
2 V max. (Load current: 100 mA, Cable length: 2 2 V max. (Load
m)
current: 50 mA,
Cable length: 2 m)
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)
Indicator *2
Protection circuits
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection
Ambient temperature Operating/Storage: -40 to 85°C (with no icing or condensation)
range
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C.
Ambient humidity
range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence
Insulation resistance
Dielectric strength
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10 times
each in X, Y, and
Z directions
500 m/s2 10 times
each in X, Y, and
Z directions
Shock resistance
(destruction)
1,000 m/s2 10 times each in X, Y, and Z
directions
1,000 m/s2 10 times each in X, Y, and Z
directions
Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, JIS C 0920 Annex 1: IP67G
Connector Models: IEC 60529 IP67
Degree of protection
Connection method
Pre-wired
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m), M12 Connector Models
Approx. 85 g
Approx. 55 g
Approx. 95 g
Approx. 70 g
Approx. 55 g
Approx. 170 g Approx. 240 g Approx. 85 g
Approx. 105 g Approx. 170 g Approx. 55 g
Approx. 95 g
Approx. 70 g
Approx. 55 g
Approx. 170 g Approx. 240 g
M12
Weight *3
Pre-wired
(packed
Approx. 105 g Approx. 170 g
Smartclick
state)
Connector
Connector Approx. 40 g
Approx. 85 g
Approx. 160 g Approx. 40 g
Approx. 85 g
Approx. 160 g
46
E2E/E2EQ NEXT Series
Types
Size
Double distance
M12 M18
Single distance
M8
M30
M8
M12
M18
M30
Item
Model
E2EQ-X2@8
E2EQ-X4@12 E2EQ-X8@18 E2EQ-X15
@30
E2EQ-X1R5@8
E2EQ-X2@12 E2EQ-X5@18 E2EQ-X10@30
Fluororesin coating
(Base material:
SUS303)
Fluororesin coating
(Base material:
SUS303)
Case
Fluororesin coating (Base material: brass)
Fluororesin coating (Base material: brass)
Sensing
surface
Fluorine resin
Materials
Clamping
nuts
Fluororesin coating (Base material: brass)
Toothed
washers
Zinc-plated iron
Cable
Vinyl chloride (PVC)
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating
hours read-out, readout of the sensor internal temperature, and initial reset
Main IO-Link
functions *2
IO-Link
specificati Ver1.1
on
IO-Link
Commun
ication
specifica
tions *2
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)
Data
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)
length
Minimum
cycle time
COM2: 2.3 ms, COM3: 0.4 ms
Accessories
Instruction manual, Clamping nuts, Toothed washer
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.
*3. Weight of the standard body-sized model.
47
E2E/E2EQ NEXT Series
Engineering Data (Reference Value)
Sensing Area
PREMIUM Model
Quadruple distance model
Triple distance model, Spatter-resistant Triple distance model
Shielded
Shielded
30
30
Y
E2E-X23@30
E2E(Q)-X22@30
X
25
Y
25
X
20
20
E2E-X14@18
E2E(Q)-X12@18
15
15
E2E(Q)-X6@12
E2E-X9@12
10
10
E2E-X4@8
E2E(Q)-X3@8
5
0
5
0
-15
-10
-5
0
5
10
15
-15
-10
-5
0
5
10
15
Distance Y (mm)
Distance Y (mm)
Unshielded
Unshielded
45
40
50
45
E2E-X40M@30
E2E-X50M@30
E2E-X30M@18
Y
40
35
Y
X
35
X
30
E2E-X20M@18
30
25
20
15
10
25
20
15
10
5
E2E-X16M@12
E2E-X10M@12
E2E-X6M@8
E2E-X8M@8
5
0
0
-40 -30 -20 -10
0
10 20 30 40
Distance Y (mm)
-30
-20
-10
0
10
20
30
Distance Y (mm)
BASIC Model
Double distance model, Spatter-resistant Double distance model
Shielded
Single distance model, Spatter-resistant Single distance model
Shielded
16
Y
12
Y
X
E2E(Q)-X10@30
X
14
10
8
E2E(Q)-X15@30
12
10
8
E2E(Q)-X8@18
E2E(Q)-X5@18
6
6
E2E(Q)-X4@12
E2E(Q)-X2@8
4
E2E(Q)-X2@12
4
2
2
E2E(Q)-X1R5@8
0
0
-20 -15 -10 -5
0
5
10 15 20
Distance Y (mm)
-20 -15 -10 -5
0
5
10 15 20
Distance Y (mm)
Unshielded
Unshielded
30
18
16
14
12
10
8
E2E-X30M@30
Y
X
Y
25
E2E-X18M@30
E2E-X10M@18
X
E2E-X16M@18
20
15
10
5
E2E-X8M@12
E2E-X4M@8
E2E-X5M@12
E2E-X2M@8
6
4
2
0
0
-40 -30 -20 -10
0
10 20 30 40
Distance Y (mm)
-40 -30 -20 -10
0
10 20 30 40
Distance Y (mm)
48
E2E/E2EQ NEXT Series
Influence of Sensing Object Size and Material
PREMIUM Model
Shielded
Quadruple distance model
Size: M8 E2E-X4@8
Triple distance model, Spatter-resistant Triple distance model
Size: M8 E2E(Q)-X3@8
4.0
5
@d
@d
t=1mm
t=1mm
X
Iron
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
X
Iron
4
Stainless steel
(SUS304)
Stainless steel
(SUS304)
3
Brass
Brass
2
Aluminum
Aluminum
Copper
Copper
1
0
0
5
10
15
20
25
30
0
5
10
15
20
25
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M12 E2E-X9@12
Size: M12 E2E(Q)-X6@12
10
8
Iron
@d
t=1mm
X
7
6
5
8
6
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
4
3
Brass
Brass
4
Aluminum
Aluminum
Copper
2
@d
Copper
t=1mm
2
X
1
0
0
0
0
10
20
30
40
50
10
20
30
40
50
Distance Y (mm)
Side length of sensing object: d (mm)
Size: M18 E2E-X14@18
Size: M18 E2E(Q)-X12@18
14
16
@d
@d
t=1mm
X
t=1mm
Iron
Iron
X
14
12
12
10
8
10
Stainless steel
(SUS304)
Stainless steel
(SUS304)
8
6
4
Brass
Brass
6
4
Aluminum
Aluminum
Copper
Copper
2
0
2
0
0
10
20
30
40
50
60
0
10
20
30
40
50
60
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M30 E2E-X23@30
Size: M30 E2E(Q)-X22@30
30
30
@d
t=1mm
X
@d
t=1mm
X
25
20
25
20
15
10
5
Iron
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
15
10
Brass
Brass
Aluminum
Aluminum
Copper
Copper
5
0
0
0
10 20 30 40 50 60 70 80 90
Side length of sensing object: d (mm)
0
10 20 30 40 50 60 70 80 90
Side length of sensing object: d (mm)
49
E2E/E2EQ NEXT Series
PREMIUM Model
Unshielded
Quadruple distance model
Size: M8 E2E-X8M@8
10
Triple distance model
Size: M8 E2E-X6M@8
8
@d
t=1mm
@
d
t=1mm
X
7
6
5
4
3
2
1
0
Iron
X
Iron
8
Stainless steel
(SUS304)
6
4
2
0
Stainless steel
(SUS304)
Brass
Brass
Aluminum
Aluminum
Copper
Copper
0
10
20
30
40
50
0
10
20
30
40
50
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M12 E2E-X16M@12
Size: M12 E2E-X10M@12
12
20
@d
t=1mm
X
@d
t=1mm
X
Iron
Iron
10
8
16
12
8
Stainless steel
(SUS304)
Stainless steel
(SUS304)
6
Brass
Brass
Aluminum
4
Aluminum
Copper
Copper
4
2
0
0
0
10
20
30
40
50
60
0
10
20
30
40
50
60
70
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M18 E2E-X30M@18
Size: M18 E2E-X20M@18
35
25
@d
@d
t=1mm
X
t=1mm
X
30
Iron
Iron
20
25
20
15
10
5
Stainless steel
(SUS304)
Stainless steel
(SUS304)
15
10
5
Brass
Brass
Aluminum
Copper
Aluminum
Copper
0
0
0
10 20 30 40 50 60 70 80 90
Side length of sensing object: d (mm)
0
10 20 30 40 50 60 70 80 90
Side length of sensing object: d (mm)
Size: M30 E2E-X50M@30
Size: M30 E2E-X40M@30
50
60
@d
t=1mm
X
@d
t=1mm
X
Iron
Iron
50
40
40
Stainless steel
(SUS304)
Stainless steel
(SUS304)
30
20
10
0
30
20
Brass
Brass
Aluminum
Copper
Aluminum
Copper
10
0
0
20
40
60
80 100 120 140 160
0
20
40
60
80
100
120
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
50
E2E/E2EQ NEXT Series
BASIC Model
Shielded
Double distance model, Spatter-resistant Double distance model Single distance model, Spatter-resistant Single distance model
Size: M8 E2E(Q)-X2@8
Size: M8 E2E(Q)-X1R5@8
2.5
3.0
@d
@d
t=1mm
X
t=1mm
X
2.5
2.0
1.5
1.0
0.5
2.0
1.5
1.0
Iron
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Brass
Brass
0.5
Aluminum
Aluminum
Copper
20
Copper
20
0
5
10
15
25
0
5
10
15
25
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M12 E2E(Q)-X4@12
Size: M12 E2E(Q)-X2@12
3.0
5
@d
@d
t=1mm
X
t=1mm
X
Iron
2.5
4
3
2
1
0
Iron
Stainless steel
(SUS304)
2.0
1.5
1.0
0.5
Stainless steel
(SUS304)
Brass
Brass
Aluminum
Aluminum
Copper
Copper
0.0
0
0
5
10
15
20
25
30
5
10
15
20
25
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M18 E2E(Q)-X8@18
Size: M18 E2E(Q)-X5@18
10
6
@d
@d
t=1mm
X
t=1mm
X
Iron
Iron
5
8
6
4
2
0
Stainless steel
(SUS304)
4
3
2
Stainless steel
(SUS304)
Brass
Brass
Aluminum
Aluminum
Copper
Copper
1
0
0
10
20
30
40
50
0
10
20
30
40
50
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M30 E2E(Q)-X15@30
Size: M30 E2E(Q)-X10@30
20
12
@d
@d
t=1mm
X
t=1mm
X
Iron
10
16
12
8
Iron
Stainless steel
(SUS304)
8
6
4
Stainless steel
(SUS304)
Brass
Brass
Aluminum
Aluminum
Copper
4
2
0
Copper
0
10
20
30
40
50
60
0
0
10
20
30
40
50
60
70
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
51
E2E/E2EQ NEXT Series
BASIC Model
Unshielded
Double distance model
Size: M8 E2E-X4M@8
Single distance model
Size: M8 E2E-X2M@8
3.0
5
@d
@d
Iron
t=1mm
X
t=1mm
X
2.5
2.0
1.5
1.0
4
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
3
2
1
0
Brass
Brass
Aluminum
Copper
Aluminum
Copper
0.5
0.0
0
5
10
15
20
25
0
5
10
15
20
25
30
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M12 E2E-X8M@12
Size: M12 E2E-X5M@12
10
6
@d
@d
Iron
t=1mm
X
t=1mm
X
Iron
5
4
3
2
8
6
4
2
0
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Brass
Brass
Aluminum
Aluminum
Copper
Copper
1
0
0
10
20
30
40
50
0
10
20
30
40
50
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M18 E2E-X16M@18
Size: M18 E2E-X10M@18
12
20
@d
@d
t=1mm
X
t=1mm
Iron
X
Iron
10
16
8
6
Stainless steel
(SUS304)
Stainless steel
(SUS304)
12
8
Brass
Brass
4
Aluminum
Aluminum
Copper
Copper
4
2
0
0
0
10
20
30
40
50
60
0
10
20
30
40
50
60
70
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Size: M30 E2E-X30M@30
Size: M30 E2E-X18M@30
25
35
@d
@d
t=1mm
X
t=1mm
Iron
X
30
20
15
10
5
Iron
25
Stainless steel
(SUS304)
20
15
10
5
Stainless steel
(SUS304)
Brass
Aluminum
Brass
Aluminum
Copper
Copper
0
0
0
10 20 30 40 50 60 70 80 90
Side length of sensing object: d (mm)
0
10 20 30 40 50 60 70 80 90
Side length of sensing object: d (mm)
52
E2E/E2EQ NEXT Series
Monitor Output vs. Sensing Distance
PREMIUM Model
Shielded
Quadruple distance model
Size: M8 E2E-X4@8
Triple model, Spatter-resistant Triple distance model
Size: M8 E2E(Q)-X3@8
250
250
@d=9 mm
@d=12 mm
225
225
t=1 mm
X
t=1 mm
X
200
200
Iron
175
Iron
175
Stainless steel
(SUS304)
Stainless steel
(SUS304)
150
150
125
125
Aluminum
Aluminum
100
75
100
75
50
50
25
0
25
0
0
1
2
3
4
5
0
1
2
3
4
5
Distance X (mm)
Distance X (mm)
Size: M12 E2E-X9@12
Size: M12 E2E(Q)-X6@12
250
250
@d=27 mm
@d=18 mm
t=1 mm
225
225
t=1mm
X
X
200
200
Iron
175
175
150
125
100
75
Iron
Stainless steel
(SUS304)
Stainless steel
150
(SUS304)
Aluminum
125
Aluminum
100
75
50
50
25
0
25
0
0
3
6
9
12
0
2
4
6
8
10
Distance X (mm)
Distance X (mm)
Size: M18 E2E-X14@18
Size: M18 E2E(Q)-X12@18
250
250
@d=42 mm
@d=36 mm
t=1 mm
225
225
t=1 mm
X
X
200
Iron
200
175
150
125
100
75
Iron
175
Stainless steel
(SUS304)
Stainless steel
(SUS304)
150
125
100
75
Aluminum
Aluminum
50
50
25
0
25
0
0
3.5
7
10.5
14
17.5
0
3
6
9
12
15
Distance X (mm)
Distance X (mm)
Size: M30 E2E-X23@30
Size: M30 E2E(Q)-X22@30
250
250
225
@d=69 mm
@d=66 mm
t=1 mm
225
t=1 mm
X
X
200
175
150
125
100
75
Iron
Iron
200
175
150
125
100
75
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Aluminum
Aluminum
50
50
25
0
25
0
0
5
10
15
20
25
0
4
8
12
16
20
24
28
Distance X (mm)
Distance X (mm)
53
E2E/E2EQ NEXT Series
PREMIUM Model
Unshielded
Quadruple distance model
Size: M8 E2E-X8M@8
Triple distance model
Size: M8 E2E-X6M@8
250
250
@d=18 mm
t=1 mm
@d=24 mm
225
225
t=1 mm
X
X
200
200
Iron
Iron
175
175
Stainless steel
(SUS304)
Stainless steel
(SUS304)
150
125
100
75
150
125
Aluminum
Aluminum
100
75
50
50
25
0
25
0
0
2
4
6
8
10
0
2
4
6
8
10
Distance X (mm)
Distance X (mm)
Size: M12 E2E-X16M@12
Size: M12 E2E-X10M@12
250
250
225
@d=48 mm
@d=30 mm
225
t=1 mm
t=1mm
X
X
200
175
150
125
100
75
200
175
150
125
100
75
Iron
Iron
Stainless steel
(SUS304)
Aluminum
Stainless steel
(SUS304)
Aluminum
50
50
25
0
25
0
0
4
8
12
16
20
0
2
4
6
8
10
12
14
Distance X (mm)
Distance X (mm)
Size: M18 E2E-X30M@18
Size: M18 E2E-X20M@18
250
250
225
@d=90 mm
@d=60 mm
225
t=1 mm
t=1 mm
X
X
200
175
150
125
100
75
200
175
150
125
100
75
Iron
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Aluminum
Aluminum
50
50
25
0
25
0
0
5
10
15
20
25
30
35
0
5
10
15
20
25
30
Distance X (mm)
Distance X (mm)
Size: M30 E2E-X50M@30
Size: M30 E2E-X40M@30
250
250
@d=150 mm
t=1 mm
@d=120 mm
t=1 mm
225
225
X
X
200
200
Iron
Iron
175
175
Stainless steel
Stainless steel
150
125
100
75
150
125
100
75
(SUS304)
Aluminum
(SUS304)
Aluminum
50
50
25
0
25
0
0
10
20
30
40
50
60
0
8
16
24
32
40
48
Distance X (mm)
Distance X (mm)
54
E2E/E2EQ NEXT Series
BASIC Model
Shielded
Double distance model, Spatter-resistant Double distance model Single distance model, Spatter-resistant Single distance model
Size: M8 E2E(Q)-X2@8
Size: M8 E2E(Q)-X1R5@8
250
250
@d=8 mm
@d=8 mm
225
225
t=1 mm
t=1 mm
X
X
200
175
150
125
100
75
200
175
Iron
Iron
Stainless steel
(SUS304)
150
Stainless steel
(SUS304)
125
Aluminum
100
75
Aluminum
50
50
25
0
25
0
0
0.5
1
1.5
2
2.5
3
3.5
4
0
0.5
1
1.5
2
2.5
3
Distance X (mm)
Distance X (mm)
Size: M12 E2E(Q)-X4@12
Size: M12 E2E(Q)-X2@12
250
250
@d=12 mm
@d=12 mm
225
225
t=1 mm
t=1 mm
X
X
200
200
175
150
125
100
75
175
Iron
Iron
Stainless steel
(SUS304)
150
Stainless steel
(SUS304)
125
100
75
Aluminum
Aluminum
50
50
25
0
25
0
0
0.5
1
1.5
2
2.5
3
3.5
4
0
1
2
3
4
5
6
7
8
Distance X (mm)
Distance X (mm)
Size: M18 E2E(Q)-X8@18
Size: M18 E2E(Q)-X5@18
250
250
@d=18 mm
@d=24 mm
225
225
t=1 mm
t=1mm
X
X
200
200
175
150
125
100
75
Iron
175
150
125
100
75
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Aluminum
Aluminum
50
50
25
0
25
0
0
1
2
3
4
5
6
7
8
9
10
0
2
4
6
8
10
12
14
16
Distance X (mm)
Distance X (mm)
Size: M30 E2E(Q)-X15@30
Size: M30 E2E(Q)-X10@30
250
250
@d=30 mm
@d=45 mm
225
225
t=1mm
t=1 mm
X
X
200
200
Iron
175
175
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
150
125
100
75
150
125
Aluminum
Aluminum
100
75
50
50
25
0
25
0
0
2
4
6
8
10 12 14 16 18 20
Distance X (mm)
0
3
6
9
12 15 18 21 24 27 30
Distance X (mm)
55
E2E/E2EQ NEXT Series
BASIC Model
Unshielded
Double distance model
Single distance model
Size: M8 E2E-X4M@8
250
Size: M8 E2E-X2M@8
250
@d=12 mm
@d=8 mm
225
225
t=1mm
X
t=1mm
X
200
175
150
125
100
75
200
175
150
125
100
75
Iron
Stainless steel
(SUS304)
Iron
Stainless steel
(SUS304)
Aluminum
Aluminum
50
50
25
0
25
0
0
1
2
3
4
5
6
7
8
0
0.5
1
1.5
2
2.5
3
3.5
4
Distance X (mm)
Distance X (mm)
Size: M12 E2E-X8M@12
250
Size: M12 E2E-X5M@12
250
@d=15 mm
@d=24 mm
225
225
t=1mm
t=1mm
X
X
200
175
150
125
100
75
200
Iron
175
Iron
150
125
100
75
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Aluminum
Aluminum
50
50
25
0
25
0
0
1
2
3
4
5
6
7
8
9
10
0
2
4
6
8
10
12
14
16
Distance X (mm)
Distance X (mm)
Size: M18 E2E-X16M@18
Size: M18 E2E-X10M@18
250
250
@d=48 mm
@d=30 mm
225
225
t=1mm
t=1mm
X
X
200
175
150
125
100
75
200
Iron
175
Iron
Stainless steel
(SUS304)
Stainless steel
150
(SUS304)
125
Aluminum
Aluminum
100
75
50
50
25
0
25
0
0
2
4
6
8
10 12 14 16 18 20
Distance X (mm)
0
4
8
12
16
20
24
28
32
Distance X (mm)
Size: M30 E2E-X30M@30
Size: M30 E2E-X18M@30
250
250
@d=90 mm
@d=54 mm
225
225
t=1mm
t=1mm
X
X
200
200
Iron
175
175
Iron
Stainless steel
150
150
125
100
75
Stainless steel
(SUS304)
(SUS304)
125
Aluminum
Aluminum
100
75
50
50
25
0
25
0
0
3
6
9
12 15 18 21 24 27 30 33 36
Distance X (mm)
0
10
20
30
40
50
60
Distance X (mm)
56
E2E/E2EQ NEXT Series
I/O Circuit Diagrams/Timing charts
DC 3-Wire
PNP output
Output circuit
IO-Link Communication mode (COM mode)
When using the Sensor connected to IO-
Link Master Unit *
Operation mode
Model
Standard I/O mode (SIO mode)
When using as a general
DC10 to 30V
Brown (1)
L+ (1)
Brown (1)
+V
Proximity
sensor
Black (4)
Proximity
sensor
main
C/Q (4)
NO
E2E(Q)-@B1
Black (4)
main
circuit
OUT
circuit
Load
Blue (3)
Blue (3)
L- (3)
0V
IO-Link master
DC10 to 30V
Brown (1)
+V
OUT
0V
Proximity
sensor
main
Black (2)
NC
E2E(Q)-@B2
---
circuit
Load
Blue (3)
Note: M8 (3-pin) Connector: (1)(4)(3)
DC10 to 30V
DC10 to 30V
Brown (1)
L+ (1)
Brown (1)
+V
Black (4)
Black (4)
OUT1
C/Q (4)
Proximity
sensor
main
Proximity
sensor
main
NO+NC
E2E(Q)-@B3
Load
circuit
White (3)
OUT2
White (3)
OUT2
circuit
DI (2)
Load
Blue (3)
Blue (3)
L- (3)
0V
IO-Link master
* In the IO-Link mode, the cord between the IO-Link master and sensor must have a length of 20 m or less.
Connector Pin Arrangement
M12 Connector
M8 (4-pin) Connector
M12 Smartclick Connector
M8 (3-pin) Connector
1
3
2
4
4
1
3
1
3
2
4
57
E2E/E2EQ NEXT Series
PNP output
Set position
Excessive proximity judgment distance *7
ProximitySensor
Unstable
Sensing
area
Nonsensing
area
Stable
Sensing area
Operation
mode *1
Output mode
Sensing
object
Rated Sensing distance
100 80
20
0
(%)
ON
Comunication indicator (green) : Always OFF
OFF
ON
Operation indicator (orange)
Control output *3
NO
NC
OFF
ON
OFF
*3. The timer function of the control
output can be set up by the IO-Link
communications. (It is able to select
ON delay, OFF delay, or one-shot
function and select a timer time of 1
to 16,383ms (T).)
ON
Comunication indicator (green) : Always OFF
Operation indicator (orange)
Control output *3
OFF
ON
OFF
ON
Standard
I/O mode
(SIO mode) *2
OFF
ON delay
OFF delay
ON
Comunication indicator (green) : Always OFF
Operation indicator (orange)
Control output 1 *3
Sensing Present
Sensing Present
OFF
ON
object
Not
object
Not
present
present
T
T
ON
1
0
1
0
ON
1
0
1
0
NO
NC
NO
NC
OFF
ON
OFF
ON
NO+NC
OFF
ON
T
T
OFF
OFF
OFF
ON
Control output 2 *3
One shot
OFF
Sensing Present
object
Not
present
Flashing
T
ON
1
0
1
0
(1sec cycle) Comunication indicator (green)
NO
NC
OFF
ON
T
ON
Operation indicator (orange)
OFF
OFF
1
*4. The excessive proximity diagnosis
function can be selected by the IO-
Link communications.
*5. The instability detection diagnosis
can be selected by the IO-Link
communications.
NO
Control output (PD1_bit0) *3
0
1
Instability detection *6 (PD1_bit4)
0
*
5
1
Excessive proximity detection (PD1_bit5)
*4
0
*6. The judgment time for the instability
detection diagnosis can be selected
by the IO-Link communications.
(For the ON delay timer function, the
setting can be selected from 0
(invalid), 10, 50, 100, 300, 500, or
1000 ms.)
*7. The judgment distance of the
excessive proximity diagnosis
function can be selected by the IO-
Link communications.
Flashing
(1sec cycle) Comunication indicator (green)
ON
Operation indicator (orange)
OFF
1
Control output (PD1_bit0) *3
IO-Link
Communication
mode
NC
0
1
Instability detection *6 (PD1_bit4)
*
5
(COM mode)
0
1
0
Excessive proximity detection (PD1_bit5)
*
4
Flashing
(The distance can be selected as a
combination of the material of the
object detected, such as iron,
aluminum, or SUS and the judgment
distance of approximately 10, 20, or
30%. However, it is not allowed to
select a combination of aluminum
and 30%.)
(1sec cycle) Comunication indicator (green)
ON
Operation indicator (orange)
OFF
1
Control output1 (PD1_bit0) *3
0
NO+NC
1
Control output2 (PD1_bit1) *3
0
1
Instability detection *6 (PD1_bit4)
*
5
Please contact your OMRON sales
representative regarding the IO-Link
setup file (IODD file).
0
1
0
Excessive proximity detection (PD1_bit5)
*4
Please contact your OMRON sales representative regarding assignment of data.
*1. For models with IO-Link, the operation mode can be changed by the IO-Link communications.
*2. If using a model with IO-Link as a general sensor or using a model without IO-Link, it operates in the standard I/O mode (SIO mode).
58
E2E/E2EQ NEXT Series
NPN output
Operation mode
Model
Output circuit
DC10 to 30V
Brown (1)
+V
Load
Proximity
sensor
main
NO
E2E(Q)-@C1
OUT
0V
Black (4)
Blue (3)
circuit
DC10 to 30V
Brown (1)
+V
Load
Proximity
sensor
main
OUT
0V
NC
E2E(Q)-@C2
Black (2)
Blue (3)
circuit
Note: M8 (3-pin) Connector: (1)(4)(3)
DC10 to 30V
+V
Brown (1)
Load
Proximity
sensor
main
Black (4)
NO+NC
E2E(Q)-@C3
Load
circuit
OUT2
White (3)
Blue (3)
0V
Connector Pin Arrangement
M12 Connector
M12 Smartclick Connector
M8 (4-pin) Connector
M8 (3-pin) Connector
1
2
4
4
2
4
3
1
1
3
3
Nonsensing
area
Stable
sensing area
ProximitySensor
Sensing
object
Operation mode
Rated Sensing distance
100
0
(%)
ON
Operation indicator (orange)
Control output
OFF
ON
NO
NC
OFF
ON
Operation indicator (orange)
Control output
OFF
ON
OFF
ON
Operation indicator (orange)
Control output 1
OFF
ON
NO+NC
OFF
ON
Control output 2
OFF
59
E2E/E2EQ NEXT Series
Connections for Sensor I/O Connectors
DC 3-Wire
Proximity Sensor
Operation
Sensor I/O Connectors
Connections *
Types
Output
Model
Model
mode
E2E/E2EQ NEXT Series
XS5
*
1
2
3
4
1
2
3
4
Brown (+)
NO
E2E(Q)-X@B1@- M1TJ/ M1
White (not connected)
Blue (–)
Black (Output)
E2E/E2EQ NEXT Series
XS5
*
1
2
3
4
1
2
3
4
Brown (+)
PNP
NC
NO+NC
NO
E2E(Q)-X@B2@-M1TJ/M1
E2E(Q)-X@B3@-M1TJ/M1
E2E(Q)-X@C1@-M1TJ/M1
E2E(Q)-X@C2@-M1TJ/M1
E2E(Q)-X@C3@-M1TJ/M1
E2E(Q)-X@B1@-M3
White (Output)
Blue (-)
Black (not connected)
E2E/E2EQ NEXT Series
XS5
XS5F-D421-@80-X@
XS5F-D42@-@80-F
XS5W-D421-@81-X@
XS5W-D42@-@81-F
*
1
2
3
4
1
2
3
4
Brown (+)
White (Output 2)
Blue (-)
Black (Output 1)
DC 3-Wire
(M12 Connector/
M12 Smartclick
Connector)
Note: For details of the
connector,
E2E/E2EQ NEXT Series
XS5
*
refer to XS5 NEXT
Series on page 87
refer to XS5 Series
on page 94
1
2
3
4
1
2
3
4
Brown (+)
White (not connected)
Blue (-)
Black (Output)
E2E/E2EQ NEXT Series
XS5
*
1
2
3
4
1
2
3
4
Brown (+)
NPN
NC
White (Output)
Blue (-)
Black (not connected)
E2E/E2EQ NEXT Series
XS5
*
1
2
3
4
1
2
3
4
Brown (+)
White (Output 2)
Blue (-)
NO+NC
Black (Output 1)
E2E/E2EQ NEXT Series
XS3
*
1
2
3
4
1
2
3
4
Brown (+)
NO
White (not connected)
Blue (-)
Black (Output)
PNP
E2E/E2EQ NEXT Series
XS3
*
1
2
3
4
1
2
3
4
Brown (+)
NC
E2E(Q)-X@B2@-M3
XS3W-M8PVC4@
XS3F-M8PVC4@
White (Output)
Blue (-)
Black (not connected)
DC 3-Wire
(M8 Connector,
4-pin)
Note: For details of the
connector,
E2E/E2EQ NEXT Series
XS3
refer to XS3W-M8/
XS3F-M8 Series
on page 102.
*
1
2
3
4
1
2
3
4
Brown (+)
NO
E2E(Q)-X@C1@-M3
White (not connected)
Blue (-)
Black (Output)
NPN
E2E/E2EQ NEXT Series
XS3
*
1
2
3
4
1
2
3
4
Brown (+)
NC
E2E(Q)-X@C2@-M3
White (Output)
Blue (-)
Black (not connected)
E2E/E2EQ NEXT Series
XS3
NO
NC
NO
NC
E2E(Q)-X@B1@-M5
E2E(Q)-X@B2@-M5
E2E(Q)-X@C1@-M5
E2E(Q)-X@C2@-M5
*
1
1
Brown (+)
PNP
NPN
XS3W-M8PVC3@
XS3F-M8PVC3@
4
3
4
3
Black (Output)
Blue (-)
DC 3-Wire
(M8 Connector,
3-pin)
Note: For details of the
connector,
E2E/E2EQ NEXT Series
XS3
refer to XS3W-M8/
XS3F-M8 Series
on page 102.
*
1
1
Brown (+)
4
3
4
3
Black (Output)
Blue (-)
Note: Different from Proximity Sensor wire colors.
* If the XS5W Series or XS3W Series Connector which has a socket and plug on the cable ends is connected to the Sensor, this part will be a plug.
60
E2E/E2EQ NEXT Series
Safety Precautions
Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/.
Warning Indications
Precautions for Correct Use
Warning level
Do not use the product in any atmosphere or environment that
Indicates a potentially hazardous situation
exceeds the ratings.
which, if not avoided, will result in minor or
WARNING
Operating Environment
1. Do not install the Sensor in the following locations.
(1) Outdoor locations directly subject to sunlight, rain, snow,
waterdroplets, or oil.
(2) Locations subject to atmospheres with chemical vapors,
inparticular solvents and acids.
moderate injury, or may result in serious
injury or death. Additionally there may be
significant property damage.
Precautions
for Safe Use
Supplementary comments on what to do or
avoid doing, to use the product safely.
(3) Locations subject to corrosive gases.
Supplementary comments on what to do or
avoid doing, to prevent failure to operate,
malfunction or undesirable effect on product
performance.
Precautions
for Correct
Use
2. The Sensor may malfunction if used near ultrasonic cleaning
equipment, high-frequency equipment, transceivers, cellular
phones, inverters, or other devices that generate a high-frequency
electric field. Please refer to the Precautions for Correct Use on
the OMRON website (www.ia.omron.com) for typical measures.
3. Laying the Proximity Sensor wiring in the same conduit or duct as
high-voltage wires or power lines may result in incorrect operation
and damage due to induction. Wire the Sensor using a separate
conduit or independent conduit.
Meaning of Product Safety Symbols
General prohibition
Indicates the instructions of unspecified
prohibited action.
4. Never use thinner or other solvents. Otherwise, the Sensor
surface may be dissolved.
Caution, explosion
Indicates the possibility of explosion under
specific conditions.
5. The following conditions shall be observed if you use the product
under an environment using cutting oil that may affect product’s
life and/or performance.
• Usage under the cutting oil condition designated by the
specification
• Usage under the cutting oil dilution ratio recommended by its
manufacturer
• Usage in oil or water is prohibited
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Impact on the product life may differ depending on the oil you use.
Before using the cutting oil, make sure that it should not cause
deterioration or degradation of sealing components.
6. When turning on the power by influence of temperature
environment, an outputmis-pulse sometimes occurs. After the
sensor has passed for 300 msec after turning on, please use in the
stable state.
Otherwise, explosion may result.
Never use the product with an AC power supply.
7. The sensor is adjusted with a high degree of accuracy, so do not
use in the environment with sudden temperature change.
8. Operation check is performed using an OMRON's IO-Link master.
If using an IO-Link master from another company, perform the
operation check in advance.
Precautions for Safe Use
The following precautions must be observed to ensure safe operation.
1. Do not use the product in environments subject to flammable or
explosive gases.
2. Do not attempt to disassemble, repair, or modify the product.
3. Do not use a voltage that exceeds the rated operating voltage
range.
Applying a voltage that is higher than the operating voltage range
may result in explosion or fire.
4. Be sure that the power supply polarity and other wiring is correct.
Incorrect wiring may cause explosion or fire.
5. If the power supply is connected directly without a load, the
internal elements may explode or burn.
6. Be sure to insert a load when connecting the power supply.
61
E2E/E2EQ NEXT Series
When the Proximity Sensor is mounted in metal, ensure that the
minimum distances given in the following table are maintained.
Design
Influence of Surrounding Metal
When mounting the Proximity Sensor using a nut, only use the
provided nut. And ensure that the minimum distances given in the
following table are maintained.
When mounting the Proximity Sensor using a nut, only use the
provided nut. Nuts that are supplied along with each Sensor are
different. Refer to Dimensions for details on shapes.
(Unit: mm)
Shielded
Models
Model
E2E-X4@8
I
4
d
30
40
60
100
20
20
50
70
8
D
4
m
12
27
42
69
9
n
20
30
70
100
18
20
54
90
12
18
27
45
12
18
27
45
E2E-X9@12
6
6
Quadruple
distance model
(Unit: mm)
E2E-X14@18
7
7
Shielded
E2E-X23@30
9
9
Type
Model
E2E-X4@8
L
3
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
d
30
40
60
100
20
20
50
70
8
D
3
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
m
12
27
42
69
9
n
20
30
70
100
18
20
54
90
12
18
27
45
12
18
27
45
E2E(Q)-X3@8
E2E(Q)-X6@12
E2E(Q)-X12@18
E2E(Q)-X22@30
E2E(Q)-X2@8
E2E(Q)-X4@12
E2E(Q)-X8@18
E2E(Q)-X15@30
E2E(Q)-X1R5@8
E2E(Q)-X2@12
E2E(Q)-X5@18
E2E(Q)-X10@30
2
2
Triple distance
model/
Spatter-resistant
Triple distance
model
4
4
18
36
66
4.5
12
24
45
4.5
8
E2E-X9@12
Quadruple
distance model
4
4
E2E-X14@18
8
8
E2E-X23@30
0
0
Double distance
model/
Spatter-resistant
Double distance
model
E2E(Q)-X3@8
E2E(Q)-X6@12
E2E(Q)-X12@18
E2E(Q)-X22@30
E2E(Q)-X2@8
E2E(Q)-X4@12
E2E(Q)-X8@18
E2E(Q)-X15@30
E2E(Q)-X1R5@8
E2E(Q)-X2@12
E2E(Q)-X5@18
E2E(Q)-X10@30
Triple distance
model/
Spatter-resistant
Triple distance
model
2.4
3.6
6
18
27
45
8
2.4
3.6
6
18
36
66
4.5
12
24
45
4.5
8
0
0
Single distance
model/
Spatter-resistant
Single distance
model
Double distance
model/
Spatter-resistant
Double distance
model
0
12
18
30
0
18
27
45
8
0
0
20
40
0
0
Unshielded
Single distance
model/
Spatter-resistant
Single distance
model
12
18
30
Models
Model
E2E-X8M@8
I
d
40
D
m
24
48
90
n
20
40
15
25
50
65
13
20
35
55
12
15
25
45
6
15
25
50
65
13
20
35
55
12
15
25
45
6
40
E2E-X16M@12
E2E-X30M@18
E2E-X50M@30
E2E-X6M@8
70
80
Quadruple
distance model
130
200
30
110
Unshielded
150 180
Models
Model
E2E-X8M@8
L
d
40
D
m
24
48
90
n
40
18
30
60
30
50
80
12
21
46
60
10
16
31
50
9
12
21
46
60
10
16
31
50
9
E2E-X10M@12
E2E-X20M@18
E2E-X40M@30 *
E2E-X4M@8
50
Triple distance
model
E2E-X16M@12
E2E-X30M@18
E2E-X50M@30
E2E-X6M@8
70
80
Quadruple
distance model
90
130
200
30
110
170
24
120 140
150 180
8
24
40
70
120
24
36
54
90
18
30
60
30
50
80
E2E-X8M@12
E2E-X16M@18
E2E-X30M@30
E2E-X2M@8
40
20
48
90
8
Double distance
model
E2E-X10M@12
E2E-X20M@18
E2E-X40M@30 *
E2E-X4M@8
50
Triple distance
model
70
90
120
24
170
24
120 140
8
24
40
70
120
24
36
54
90
E2E-X5M@12
E2E-X10M@18
E2E-X18M@30
15
22
30
40
15
22
30
20
40
70
Single distance
model
E2E-X8M@12
E2E-X16M@18
E2E-X30M@30
E2E-X2M@8
11
21
40
6
40
11
21
40
6
20
48
90
8
Double distance
model
55
70
90
120
24
* If you use the model E2E-X40M@30, the panel thickness (t) is 4 mm
or less.
E2E-X5M@12
E2E-X10M@18
E2E-X18M@30
11
18
25
40
11
18
25
20
40
70
Single distance
model
55
90
* If you use the model E2E-X40M@30, the panel thickness (t) is 4 mm
or less.
62
E2E/E2EQ NEXT Series
Mutual Interference
When installing two or more Proximity Sensors face-to-face or side-
by-side, ensure that the minimum distances given in the following
table are maintained.
Mounting
Tightening Force
Do not tighten the nut with excessive force.
A washer must be used with the nut.
Shielded Models
Unshielded Models
B
A
Part B Part A
Part B Part A
Note: 1. The allowable tightening strength depends on the distance
from the edge of the head, as shown in the following table.
(A is the distance from the edge of the head. B includes the
nut on the head side. If the edge of the nut is in part A, the
tightening torque for part A applies instead.)
(Unit: mm)
Shielded
Item
Models
Model
E2E-X4@8
A
40
B
2. The following strengths assume washers are being used.
20
35
50
90
20
30
45
90
15
20
35
90
15
20
35
70
Quadruple distance model, Triple distance model,
Spatter-resistant Triple distance model
E2E-X9@12
60
Quadruple
distance model
E2E-X14@18
90
Part A
Part B
E2E-X23@30
150
25
Size
Shielded
Dimension
(mm)
E2E(Q)-X3@8
E2E(Q)-X6@12
E2E(Q)-X12@18
E2E(Q)-X22@30
E2E(Q)-X2@8
E2E(Q)-X4@12
E2E(Q)-X8@18
E2E(Q)-X15@30
E2E(Q)-X1R5@8
E2E(Q)-X2@12
E2E(Q)-X5@18
E2E(Q)-X10@30
Triple distance
model/
Spatter-resistant
Triple distance
model
Torque
Torque
40
Shielded
9
3
70
M8
4 N·m
10 N·m
15 N·m
Unshielded
Shielded
150
20
16
9
Double distance
model/
Spatter-resistant
Double distance
model
M12
M18
M30
6 N·m
15 N·m
40 N·m
Unshielded
Shielded
30
16
3
60 N·m
(30 N·m *)
60
Unshielded
Shielded
110
20
23
8
Single distance
model/
Spatter-resistant
Single distance
model
80 N·m
Unshielded
30
* If using the E2EQ (M18), refer to this torque value.
50
100
Double distance model, Single distance model,
Spatter-resistant Triple distance model,
Spatter-resistant Single distance model
Unshielded
Item
Part A
Part B
Models
Model
A
B
Size
Shielded
Dimension
(mm)
Torque
Torque
E2E-X8M@8
80
60
E2E-X16M@12
E2E-X30M@18
E2E-X50M@30
E2E-X6M@8
160
360
700
80
120
300
480
60
Shielded
9
Quadruple
distance model
M8
9 N·m
12 N·m
Unshielded
3
M12
M18
M30
---
---
---
---
---
---
30 N·m
70 N·m
E2E-X10M@12
E2E-X20M@18
E2E-X40M@30
E2E-X4M@8
120
200
380
80
100
120
300
60
180 N·m (100 N·m *)
Triple distance
model
* If using the E2EQ (M30), refer to this torque value.
E2E-X8M@12
E2E-X16M@18
E2E-X30M@30
E2E-X2M@8
120
200
350
80
100
120
300
60
Double distance
model
E2E-X5M@12
E2E-X10M@18
E2E-X18M@30
120
200
300
100
110
200
Single distance
model
63
E2E/E2EQ NEXT Series
Dimensions
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensors
PREMIUM Model
E2E/E2EQ NEXT Series
(Quadruple distance/Triple distance/Spatter-resistant, Triple distance model)
DC 3-Wire
Pre-wired Model/Pre-wired Connector Model
Shielded/Unshielded
Connector Models
(M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)
Shielded/Unshielded
B
B
C
D
Indicators
D
F
Indicators
F
Standard I/O mode (SIO mode):
Operation indicator (orange/ON),
comunication indicator (green/OFF)
IO-Link Communication mode (COM mode):
Operation indicator (orange/ON),
comunication indicator
G
H
G
H
E
Standard I/O mode (SIO mode):
Operation indicator (orange/ON),
communication indicator (green/OFF)
IO-Link Communication mode (COM mode):
Operation indicator (orange/ON),
comunication indicator
I
E
I
(green/Flashing (1sec cycle)
(green/Flashing (1sec cycle)
A
C
A
J
Two clamping nuts
Toothed washer
J
Toothed washer
Two clamping nuts
Pre-wired Models
(Operation mode: NO, NC Type)
Pre-wired Connector Models (M1TJ)
M12×P1
Model E2E(Q)-X@8-M1;
Shape of connection.
Shielded
Model
Vinyl-insulated round cable with
3 conductors
M8, M12 size: 4-dia.
M18, M30 size: 6-dia.
(Conductor cross section:
0.2 mm2 (AWG24),
Insulator diameter: 1.05 mm),
Standard length: 2 m
A
B
C
D
E
F
G*
H
4
4
I
J
(Operation mode: NO, NC Type)
Vinyl-insulated round cable with
3 conductors
M8, M12 size: 4-dia.
M18, M30 size: 6-dia.
(Conductor cross section:
0.2 mm2 (AWG24),
Insulator diameter: 1.05 mm),
Standard length: 0.3 m
E2E(Q)-X@8-M3/
M5
M8XP1 39 M8XP1
26
1
10
4
15 13
E2E(Q)-X@8-M1 M8XP1 43 M12XP1 26
E2E(Q)-X@12-M1 M12XP1 48 M12XP1 33
E2E(Q)-X@18-M1 M18XP1 53 M12XP1 38
E2E(Q)-X@30-M1 M30XP1.5 58 M12XP1 43
1
1
1
1
1
1
1
1
1
10
12
12
12
4
4
4
4
15 13
5.5 21 17
6
7
4
4
29 24
42 36
15 13
15 13
(Operation mode: NO+NC Type)
(Operation mode: NO+NC Type)
Vinyl-insulated round cable with
4 conductors
E2E-X@L8-M3/M5 M8XP1 49 M8XP1
36
10 ---
10 ---
E2E-X@L8-M1
E2E-X@L12-M1
E2E-X@L18-M1
E2E-X@L30-M1
M8XP1 53 M12XP1 36
M12 size: 4.3-dia.
Vinyl-insulated round cable with
4 conductors
M12 size: 4.3-dia.
M18/M30 size: 6-dia.
(Conductor cross section: 0.2 mm2
(AWG24),
M18, M30 size: 6-dia.
(Conductor cross section: 0.2 mm2
(AWG24),
Insulator diameter: 1.05 mm),
Standard length: 0.3 m
M12XP1 70 M12XP1 55
M18XP1 75 M12XP1 60
M30XP1.5 80 M12XP1 65
12 --- 5.5 21 17
12 ---
12 ---
6
7
29 24
42 36
Insulator diameter: 1.05 mm),
Standard length: 2 m
Unshielded
Model
A
B
C
D
E
F
8
8
G*
---
---
H
I
J
Shielded
E2E-X@M@8-M3/
M5
M8XP1 39 M8XP1
26
6
3
15 13
Model
A
B
C
D
E
1
1
1
1
1
1
1
1
F
G*
4
H
I
J
E2E(Q)-X@8
M8XP1
37.8 4.4 26
47.1 3.7 33
55.3 8.5 38
10
12
12
12
4
15 13
E2E-X@M@8-M1 M8XP1 43 M12XP1 26
E2E-X 12-M1 M12XP1 48 M12XP1 33
L8-M3/M5 M8XP1 49 M8XP1 36
M8XP1 53 M12XP1 36
L12-M1 M12XP1 70 M12XP1 55
6
7
6
6
7
3
4
3
3
4
4
5
5
15 13
21 17
15 13
15 13
21 17
29 24
42 36
42 36
E2E(Q)-X@12 M12XP1
E2E(Q)-X@18 M18XP1
4
5.5 21 17
@M@
10 ---
4
6
7
4
29 24
42 36
15 13
E2E-X@M@
8
8
---
---
E2E(Q)-X@30 M30XP1.5 60.3 8.3 43
4
E2E-X
E2E-X
E2E-X
@
@
@
M
M
M
@
@
@
L8-M1
E2E-X@L8
E2E-X@L12
E2E-X@L18
E2E-X@L30
M8XP1
47.8 4.4 36
69.1 3.7 55
77.3 8.5 60
10 ---
10 ---
M12XP1
M18XP1
12 --- 5.5 21 17
L18-M1 M18XP1 75 M12XP1 60 13 12 ---
L30-M1 M30XP1.5 80 M12XP1 65 15 10 ---
L30-M1 M30XP1.5 95 M12XP1 80 15 12 ---
12 ---
12 ---
6
7
29 24
42 36
E2E-X40M
@
@
M30XP1.5 82.3 8.3 65
E2E-X50M
* Mounting part of sensor lock O-ring (Y92E-J@S@) ---:Out of a subject.
Unshielded
Model
A
B
C
D
E
6
7
F
G*
H
3
4
I
J
Mounting Hole Dimensions
Angle R of the
Bending Wire
10 mm
Wire pullout position
E2E-X@M@8 M8XP1
E2E-X@M@12 M12XP1
37.8 4.4 26
47.1 3.7 33
8
---
15 13
21 17
Sc
10 ---
---
10 ---
E2E-
F
M8XP1
X@M@L8
47.8 4.4 36
69.1 3.7 55
6
7
8
3
15 13
R
Dimensions
M8
F (mm)
E2E-X
@
M
@
L12 M12XP1
L18 M18XP1
4
4
5
5
21 17
29 24
42 36
42 36
Dimensions Sc (mm)
Dimensions R (mm)
+0.5
0
8.5 dia.
E2E-X@
M
@
77.3 8.5 60 13 12 ---
M8
- (0)
M12
M8
12
+0.5
0
M12
M18
M30
12.5 dia.
18.5 dia.
30.5 dia.
E2E-S05S12
@
@
M30XP1.5 82.3 8.3 65 15 10 ---
M12
+0.5
0
E2E-S05S12
M30X1.5
97.3 8.3 80 15 12 ---
M18
2.5
M18
18
+0.5
0
M30
M30
* Mounting part of sensor lock O-ring (Y92E-J@S@) ---: Out of a subject.
64
E2E/E2EQ NEXT Series
BASIC Model
E2E/E2EQ NEXT Series
(Double distance/Single distance/Spatter-resistant, Double distance/Single distance model)
DC 3-Wire
Connector Models
(M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)
Shielded/Unshielded
Pre-wired Model/Pre-wired Connector Model
Shielded/Unshielded
B
B
D
C
D
Indicators
F
H
G
Standard I/O mode (SIO mode):
Operation indicator (orange/ON),
comunication indicator (green/OFF)
IO-Link Communication mode (COM mode):
Operation indicator (orange/ON),
comunication indicator
F
E
Indicators
I
G
H
E
Standard I/O mode (SIO mode):
Operation indicator (orange/ON),
comunication indicator (green/OFF)
IO-Link Communication mode (COM mode):
Operation indicator (orange/ON),
comunication indicator
I
(green/Flashing (1sec cycle)
A
C
(green/Flashing (1sec cycle)
J
A
J
Two clamping nuts
Toothed washer
Toothed washer
Model E2E(Q)-X@8-M1;
Shape of connection.
Two clamping nuts
Pre-wired Models
Pre-wired Connector Models (M1TJ)
(Operation mode: NO, NC Type)
M12×P1
Shielded
F
G
Model
A
B
C
D
E
H
3
3
4
4
5
I
J
*1 *2
E2E(Q)-X@30
X@8-M3/M5
10
4
Vinyl-insulated round cable with
3 conductors
M8, M12 size: 4-dia.
M18, M30 size: 6-dia.
(Conductor cross section:
0.2 mm2 (AWG24),
Insulator diameter: 1.05 mm),
Standard length: 2 m
M8XP1
39 M8XP1 26 ---
43 M12XP1 26 ---
48 M12XP1 33 ---
53 M12XP1 38 ---
15 13
15 13
21 17
29 24
42 36
(8)
(Operation mode: NO, NC Type)
10
4
Vinyl-insulated round cable with
3 conductors
M8, M12 size: 4-dia.
M18, M30 size: 6-dia.
(Conductor cross section:
0.2 mm2 (AWG24),
E2E(Q)-X@8-M1 M8XP1
(8)
12
4
E2E(Q)-X
E2E(Q)-X
E2E(Q)-X
@
@
@
12-M1 M12XP1
(10)
12
4
18-M1 M18XP1
Insulator diameter: 1.05 mm),
Standard length: 0.3 m
(10)
(Operation mode: NO+NC Type)
12
4
30-M1 M30XP1.5 58 M12XP1 43 ---
(10)
(Operation mode: NO+NC Type)
E2E-X
@
L8-M3/M5 M8XP1
49 M8XP1 36 ---
53 M12XP1 36 ---
8
8
---
---
3
3
4
4
5
15 13
15 13
21 17
29 24
42 36
Vinyl-insulated round cable with
4 conductors
M12 size: 4.3-dia.
M18, M30 size: 6-dia.
(Conductor cross section: 0.2 mm2
(AWG24),
Insulator diameter: 1.05 mm),
Standard length: 0.3 m
Vinyl-insulated round cable with
4 conductors
M12 size: 4.3-dia.
M18, M30 size: 6-dia.
(Conductor cross section: 0.2 mm2
(AWG24),
Insulator diameter: 1.05 mm),
Standard length: 2 m
E2E-X@L8-M1
E2E-X@L12-M1
E2E-X@L18-M1
E2E-X@L30-M1
M8XP1
M12XP1 70 M12XP1 55 --- 10 ---
M18XP1 75 M12XP1 60 --- 10 ---
M30XP1.5
80 M12XP1 65 --- 10 ---
Unshielded
Model
Shielded
E
*3
G
*2
A
B
C
D
F
H
I
J
Model
A
B
C
D
E
F *1
G *2
4
H
3
4
4
5
3
4
4
5
I
J
E2E-X@
M
@8-M3/M5 M8XP1
39 M8XP1 26
43 M12XP1 26
6
6
7
8
8
---
---
3
3
4
4
5
3
3
4
4
15 13
15 13
21 17
29 24
42 36
15 13
15 13
21 17
29 24
E2E(Q)-X@8
M8XP1
37.8 4.4 26 --- 10 (8)
47.1 3.7 33 --- 12 (10)
55.3 8.5 38 --- 12 (10)
15 13
21 17
29 24
42 36
15 13
21 17
29 24
42 36
E2E-X@M@8-M1 M8XP1
E2E(Q)-X@12 M12XP1
E2E(Q)-X@18 M18XP1
4
E2E-X
E2E-X
E2E-X
@
@
@
M
M
M
@12-M1
@18-M1
@30-M1
M12XP1 48 M12XP1 26
10 ---
4
M18XP1 53 M12XP1 38 10 10 ---
M30XP1.5 58 M12XP1 43 13 10 ---
E2E(Q)-X@30 M30XP1.5 60.3 8.3 43 --- 12 (10)
4
E2E-X@L8
E2E-X@L12
E2E-X@L18
E2E-X@L30
M8XP1
47.8 4.4 36 ---
69.1 3.7 55 ---
77.3 8.5 60 ---
8
---
---
---
---
E2E-X@
M
@L8-M3-M5 M8XP1
49 M8XP1 36
53 M12XP1 36
6
6
7
8
8
---
---
E2E-X@
M
M
@L8-M1 M8XP1
M12XP1
M18XP1
10
10
10
E2E-X@
@L12-M1 M12XP1 70 M12XP1 55
10 ---
E2EX@
M
@L18-M1 M18XP1 75 M12XP1 60 10 10 ---
M30XP1.5 82.3 8.3 65 ---
130
(15)
E2E-X@
M
@L30-M1 M30XP1.5 80 M12XP1 65
10 ---
5
42 36
Unshielded
*1. If using the E2EQ, refer to ( ) dimensions.
*2. Mounting part of sensor lock O-ring (Y92E-J
*3. When using X30M@30, refer to (15).
Model
A
B
C
D
E *3
6
F
G *2
H
3
4
4
5
3
4
4
5
I
J
@S
@
) ---: Out of a subject.
E2E-X@M@8
M8XP1
37.8 4.4 26
47.1 3.7 33
55.3 8.5 38
8
---
15 13
21 17
29 24
42 36
15 13
21 17
29 24
42 36
E2E-X@M@12 M12XP1
E2E-X@M@18 M18XP1
7
10 ---
10 ---
10 ---
Mounting Hole Dimensions
Angle R of the
Bending Wire
10 mm
Wire pullout position
10
13
6
Sc
E2E-X@M@30 M30XP1.5 60.3 8.3 43
E2E-X@M@L8 M8XP1
47.8 4.4 36
69.1 3.7 55
77.3 8.5 60
8
---
F
E2E-X
E2E-X
E2E-X
@
@
@
M
M
M
@
@
@
L12 M12XP1
7
10 ---
10 ---
R
Dimensions
M8
F (mm)
L18 M18XP1
10
Dimensions Sc (mm)
Dimensions R (mm)
+0.5
8.5 dia.
L30 M30XP1.5 82.3 8.3 65 130 (15) 10 ---
0
M8
- (0)
M12
M8
12
+0.5
0
M12
M18
M30
12.5 dia.
18.5 dia.
30.5 dia.
*1. If using the E2EQ, refer to ( ) dimensions.
*2. Mounting part of sensor lock O-ring (Y92E-J
*3. When using X30M@30, refer to (15).
M12
@S@) ---: Out of a subject.
+0.5
0
M18
2.5
M18
18
+0.5
0
M30
M30
65
E2E/E2EQ NEXT Series
Accessories (Sold Separately)
e-jig (Mounting Sleeves)
Y92E-J12S18
Y92E-J8S12
35
23.3
28
3
3
18
26.8 dia.
24
19 dia.
26.8 dia.
24
4
4
21.2 dia.
19
17
M12 × 1
Sensor lock nut
Mounting Sleeve
M18 × 1
Two Mounting Sleeve
clamping nuts
Sensor lock nut
Mounting Sleeve
Two Mounting Sleeve
clamping nuts
M16×1
7
0.7
8.8
0.7
M20×1
8 dia.
A
A
12 dia.
Section A-A
A
A
Section A-A
Y92E-J18S30
Material
Polyetheretherketone (PEEK) /
40
Mounting Sleeve
5
23.2
Polybutylene terephthalate (PBT)
Polybutylene terephthalate (PBT)
Polybutylene terephthalate (PBT)
5
40 dia.
36
40.8 dia.
36
Mounting Sleeve
clamping nut
Sensor lock nut
Sensor lock O-ring
Material combining HNBR and fluororubber
M30 × 1.5
Sensor lock nut
Mounting Sleeve
Tightening Force
Two Mounting Sleeve
clamping nuts
Torque
11.9
M30 × 1.5
0.7
Model
Mounting Sleeve
Sensor lock nut
clamping nut
Y92E-J8S12
Y92E-J12S18
Y92E-J18S30
0.6 N·m
1.2 N·m
5 N·m
0.6 N·m
1.2 N·m
3.5 N·m
18 dia.
A
A
Section A-A
66
Proximity Sensor
E2E/E2EQ NEXT Series
DC 2-wire
Long-distance Detection Prevents
Unexpected Facility Stoppages
• The world's longest sensing distance*1
Nearly double the sensing distance of previous
• With high-brightness LED, the indicator is visible
anywhere from 360°.
• Only 10 Seconds*2 to Replace a Proximity Sensor
with the "e-jig" (Mounting Sleeve).
• Cables with enhanced oil resistance enabled 2-year
oil resistance*3.
• UL certification (UL60947-5-2) and CSA certification
(CSA C22.2 UL60947-5-2-14)
*1. Based on July 2017 OMRON investigation.
*2. Time required to adjust the distance when installing a Sensor.
For the most recent information on models that have been certified
for safety standards, refer to your OMRON website.
Based on OMRON investigation.
*3. Refer to page 72 and 74 for details. However, E2EQ series is
excluded.
Be sure to read Safety Precautions on
page 80.
E2E/E2EQ NEXT Series Model Number Legend
DC 2-wire
(1)
(2) (3)
(4) (5) (6) (7) (8) (9) (10)
(11)
-
-
-
-
E2E
X
D
No.
(1)
(2)
(3)
Classification
Code
Meaning
Blank
Without spatter-resistant coating
With spatter-resistant coating
Case
Q
Sensing distance
Shielding
Number
Sensing distance (Unit: mm) (R: Indication of decimal point)
Blank
M
Shielded Models
Unshielded Models
Normally open (NO)
Normally closed (NC)
Standard
1
(4)
(5)
Operation mode
Body size
2
Blank
L
Long Body
M8
8
Size
12
18
30
M12
(6)
(7)
(Omitted for the Single
distance type.)
M18
M30
Blank
M1TGJ
M1TGJR
Pre-wired Models
Connecting method
M12 Pre-wired Smartclick Connector Models
M12 Pre-wired Smartclick Connector Models (Robot (bending-resistant) PVC cable)
Blank
T
Polarity
(8)
(9)
Polarity
No polarity
Blank
R
Standard PVC cable
Cable specifications *
Robot (bending-resistant) PVC cable
Other than Single distance model (Pre-wired Models)
Single distance model (Applicable only to Pre-wired Models)
Blank
N
(10) New model
(11) Cable length
Number M Cable length
* (9) is only shown in the model number of Pre-wired Models.
Note: 1. The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
Models are not available for all combinations of code numbers.
2. Size description of the number 7 is not included in the Single-distance type.
67
E2E/E2EQ NEXT Series
Ordering Information
Sensors
E2E NEXT Series (Triple distance model)
DC 2-wire [Refer to Dimensions on page 82.]
Shielded Models *1
Model
Size
Connection method
(Sensing distance)
Polarity
Operation mode: NO
E2E-X3D18 2M
Operation mode: NC
E2E-X3D28 2M
Yes
No
Pre-wired (2 m) *2 *3
M8
E2E-X3D18-T 2M
E2E-X3D28-T 2M
(3 mm)
Yes
No
E2E-X3D18-M1TGJ 0.3M
E2E-X3D18-M1TGJ-T 0.3M
E2E-X7D112 2M
E2E-X3D28-M1TGJ 0.3M
E2E-X3D28-M1TGJ-T 0.3M
E2E-X7D212 2M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
Yes
No
Pre-wired (2 m) *2 *3
M12
E2E-X7D112-T 2M
E2E-X7D212-T 2M
(7 mm)
Yes
No
E2E-X7D112-M1TGJ 0.3M
E2E-X7D112-M1TGJ-T 0.3M
E2E-X11D118 2M
E2E-X7D212-M1TGJ 0.3M
E2E-X7D212-M1TGJ-T 0.3M
E2E-X11D218 2M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
Yes
No
Pre-wired (2 m) *2 *3
M18
E2E-X11D118-T 2M
E2E-X11D218-T 2M
(11 mm)
Yes
No
E2E-X11D118-M1TGJ 0.3M
E2E-X11D118-M1TGJ-T 0.3M
E2E-X20D130 2M
E2E-X11D218-M1TGJ 0.3M
E2E-X11D218-M1TGJ-T 0.3M
E2E-X20D230 2M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
Yes
No
Pre-wired (2 m) *2 *3
M30
E2E-X20D130-T 2M
E2E-X20D230-T 2M
(20 mm)
Yes
No
E2E-X20D130-M1TGJ 0.3M
E2E-X20D130-M1TGJ-T 0.3M
E2E-X20D230-M1TGJ 0.3M
E2E-X20D230-M1TGJ-T 0.3M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
Unshielded Models
Model
Size
Connection method
(Sensing distance)
Polarity
Operation mode: NO
E2E-X6MD18 2M
Operation mode: NC
E2E-X6MD28 2M
Yes
No
Pre-wired (2 m) *2 *3
M8
E2E-X6MD18-T 2M
E2E-X6MD28-T 2M
(6 mm)
Yes
No
E2E-X6MD18-M1TGJ 0.3M
E2E-X6MD18-M1TGJ-T 0.3M
E2E-X10MD112 2M
E2E-X6MD28-M1TGJ 0.3M
E2E-X6MD28-M1TGJ-T 0.3M
E2E-X10MD212 2M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
Yes
No
Pre-wired (2 m) *2 *3
M12
E2E-X10MD112-T 2M
E2E-X10MD212-T 2M
(10 mm)
Yes
No
E2E-X10MD112-M1TGJ 0.3M
E2E-X10MD112-M1TGJ-T 0.3M
E2E-X20MD1L18 2M
E2E-X10MD212-M1TGJ 0.3M
E2E-X10MD212-M1TGJ-T 0.3M
E2E-X20MD2L18 2M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
Yes
No
Pre-wired (2 m) *2 *3
M18
E2E-X20MD1L18-T 2M
E2E-X20MD2L18-T 2M
(20 mm)
Yes
No
E2E-X20MD1L18-M1TGJ 0.3M
E2E-X20MD1L18-M1TGJ-T 0.3M
E2E-X40MD1L30 2M
E2E-X20MD2L18-M1TGJ 0.3M
E2E-X20MD2L18-M1TGJ-T 0.3M
E2E-X40MD2L30 2M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
Yes
No
Pre-wired (2 m) *2 *3
M30
E2E-X40MD1L30-T 2M
E2E-X40MD2L30-T 2M
(40 mm)
Yes
No
E2E-X40MD1L30-M1TGJ 0.3M
E2E-X40MD1L30-M1TGJ-T 0.3M
E2E-X40MD2L30-M1TGJ 0.3M
E2E-X40MD2L30-M1TGJ-T 0.3M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 81.
*2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2E-X3D18 5M)
*3. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X3D18-R 2M/E2E-
X3D18-R 5M)
*4. Models with M12 Pre-wired Smartclick Connectors and robot (bending-resistant) cables are also available with "R" in the model number.
(Example: E2E-X3D18-M1TGJR 0.3M/E2E-X3D18-M1TGJR-T 0.3M)
68
E2E/E2EQ NEXT Series
Sensors
E2EQ NEXT Series (Spatter-resistant Triple distance model)
DC 2-wire [Refer to Dimensions on page 84.]
Shielded Models *1
Model
Size
Connection method
Polarity
(Sensing distance)
Operation mode: NO
E2EQ-X3D18 2M
Operation mode: NC
Yes
No
E2EQ-X3D28 2M
Pre-wired (2 m) *2
E2EQ-X3D18-T 2M
E2EQ-X3D28-T 2M
M8
(3 mm)
Yes
No
E2EQ-X3D18-M1TGJ 0.3M
E2EQ-X3D18-M1TGJ-T 0.3M
E2EQ-X7D112 2M
E2EQ-X3D28-M1TGJ 0.3M
E2EQ-X3D28-M1TGJ-T 0.3M
E2EQ-X7D212 2M
M12 Pre-wired
Smartclick Connector (0.3 m)
Yes
No
Pre-wired (2 m) *2
E2EQ-X7D112-T 2M
E2EQ-X7D212-T 2M
M12
(7 mm)
Yes
No
E2EQ-X7D112-M1TGJ 0.3M
E2EQ-X7D112-M1TGJ-T 0.3M
E2EQ-X11D118 2M
E2EQ-X7D212-M1TGJ 0.3M
E2EQ-X7D212-M1TGJ-T 0.3M
E2EQ-X11D218 2M
M12 Pre-wired
Smartclick Connector (0.3 m)
Yes
No
Pre-wired (2 m) *2
E2EQ-X11D118-T 2M
E2EQ-X11D218-T 2M
M18
(11 mm)
Yes
No
E2EQ-X11D118-M1TGJ 0.3M
E2EQ-X11D118-M1TGJ-T 0.3M
E2EQ-X20D130 2M
E2EQ-X11D218-M1TGJ 0.3M
E2EQ-X11D218-M1TGJ-T 0.3M
E2EQ-X20D230 2M
M12 Pre-wired
Smartclick Connector (0.3 m)
Yes
No
Pre-wired (2 m) *2
E2EQ-X20D130-T 2M
E2EQ-X20D230-T 2M
M30
(20 mm)
Yes
No
E2EQ-X20D130-M1TGJ 0.3M
E2EQ-X20D130-M1TGJ-T 0.3M
E2EQ-X20D230-M1TGJ 0.3M
E2EQ-X20D230-M1TGJ-T 0.3M
M12 Pre-wired
Smartclick Connector (0.3 m)
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 81.
*2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EQ-X3D18 5M)
E2E NEXT Series (Single distance model)
DC 2-wire [Refer to Dimensions on page 85.]
Shielded Models
Model
Size
Connection method
Polarity
(Sensing distance)
Operation mode: NO
E2E-X1R5D1-N 2M
Operation mode: NC
E2E-X1R5D2-N 2M
Yes
No
Pre-wired (2 m) *2 *3
E2E-X1R5D1-T-N 2M
E2E-X1R5D2-T-N 2M
M8
(1.5 mm)
Yes
No
E2E-X1R5D1-M1TGJ 0.3M
E2E-X1R5D1-M1TGJ-T 0.3M
E2E-X2R5D1-N 2M
E2E-X1R5D2-M1TGJ 0.3M
E2E-X1R5D2-M1TGJ-T 0.3M
E2E-X2R5D2-N 2M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
Yes
No
Pre-wired (2 m) *2 *3
E2E-X2R5D1-T-N 2M
E2E-X2R5D2-T-N 2M
M12
(2.5 mm)
Yes
No
E2E-X2R5D1-M1TGJ 0.3M
E2E-X2R5D1-M1TGJ-T 0.3M
E2E-X5D1-N 2M
E2E-X2R5D2-M1TGJ 0.3M
E2E-X2R5D2-M1TGJ-T 0.3M
E2E-X5D2-N 2M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
Yes
No
Pre-wired (2 m) *2 *3
E2E-X5D1-T-N 2M
E2E-X5D2-T-N 2M
M18
(5 mm)
Yes
No
E2E-X5D1-M1TGJ 0.3M
E2E-X5D1-M1TGJ-T 0.3M
E2E-X5D2-M1TGJ 0.3M
E2E-X5D2-M1TGJ-T 0.3M
M12 Pre-wired
Smartclick Connector (0.3 m) *4
*1. Models with 5-m cable length are also available with "5M" suffix. (Example: E2E-X1R5D1-N 5M)
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X1R5D1-R-N 2M/
E2E-X1R5D1-R-N 5M)
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with "R" in the model number. (Example: E2E-
X1R5D1-M1TGJR 0.3M/E2E-X1R5D1-M1TGJR-T 0.3M)
69
E2E/E2EQ NEXT Series
Accessories (Sold Separately)
Sensor I/O Connectors
(Models for Pre-wired Connectors) A Sensor I/O Connector is not provided with the Sensor. It must be ordered separately as required.
Round Oil-resistant Connectors XS5 NEXT series
Cable
diameter
(mm)
Cable
length
(m)
Cable
Specification
Cable Connection
Direction
Sensor I/O Connector
model number
Applicable Proximity
Sensor model number
Appearance
Type
1
2
XS5F-D421-C80-X
XS5F-D421-D80-X
XS5F-D421-E80-X
XS5F-D421-G80-X
XS5F-D421-J80-X
XS5F-D421-C80-XR
XS5F-D421-D80-XR
XS5F-D421-E80-XR
XS5F-D421-G80-XR
XS5F-D421-J80-XR
XS5W-D421-C81-X
XS5W-D421-D81-X
XS5W-D421-E81-X
XS5W-D421-G81-X
XS5W-D421-J81-X
XS5W-D421-C81-XR
XS5W-D421-D81-XR
XS5W-D421-E81-XR
XS5W-D421-G81-XR
XS5W-D421-J81-XR
Oil-resistant
PVC cable
Sockets on One
Cable End
6 dia.
6 dia.
6 dia.
6 dia.
Straight
Straight
3
5
10
1
M12
Smartclick
Connector
2
Oil-resistant
PVC robot cable Cable End
Sockets on One
3
5
Straight type
10
1
E2E-X@D@-M1TGJ(R)(-T)
E2EQ-X@D@-M1TGJ(-T)
2
Oil-resistant
PVC cable
Socket and Plug
on Cable Ends
Straight (Socket)/
Straight (Plug)
3
5
10
1
2
Oil-resistant
PVC robot cable on Cable Ends
Socket and Plug
Straight (Socket)/
Straight (Plug)
3
5
10
Note: For details of the connector, refer to XS5 NEXT Series on page 87.
Round Water-resistant Connectors XS5 series
Cable
diameter
(mm)
Cable
length
(m)
Cable
Specification
Cable Connection
Direction
Sensor I/O Connector
model number
Applicable Proximity
Sensor model number
Appearance
Type
1
2
XS5F-D421-C80-F
XS5F-D421-D80-F
XS5F-D421-E80-F
XS5F-D421-G80-F
XS5F-D421-J80-F
XS5F-D422-C80-F
XS5F-D422-D80-F
XS5F-D422-E80-F
XS5F-D422-G80-F
XS5F-D422-J80-F
XS5W-D421-C81-F
XS5W-D421-D81-F
XS5W-D421-E81-F
XS5W-D421-G81-F
XS5W-D421-J81-F
XS5W-D422-D81-F
XS5W-D422-G81-F
Straight
3
5
10
1
Sockets on One
Cable End
M12
Smartclick
Connector
6 dia.
2
Right-angle
3
Straight type
5
10
1
E2E-X@D@-M1TGJ(R)(-T)
E2EQ-X@D@-M1TGJ(-T)
PVC robot cable
2
Straight (Socket)/
Straight (Plug)
3
5
Right-angle type
10
2
Socket and Plug
on Cable Ends
Right-angle (Socket)/
Right-angle (Plug)
6 dia.
5
2
5
2
5
XS5W-D423-D81-F
XS5W-D423-G81-F
XS5W-D424-D81-F
XS5W-D424-G81-F
Straight (Socket)/
Right-angle (Plug)
Right-angle (Socket)/
Straight (Plug)
Note: For details of the connector, refer to XS5 Series on page 94.
70
E2E/E2EQ NEXT Series
Sensor I/O Connectors Oil resistance performance of mating combination
Applicable connector Model
E2E NEXT Series
Pre-wired Connector Models
XS5 NEXT series
2 years of oil resistance*
XS5 series
E2E-X@D@-M1TGJ(R)(-T)
Water-resistant (IP67)
* Applicable cutting oil type: specified in JIS K 2241:2000
2 years of oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).
Products to be shipped will have around 2 years of oil resistance, but will very depending on the product.
e-jig (Mounting Sleeves) [Refer to Dimensions on page 86.]
A Mounting Bracket is not provided with the Sensor. It must be ordered separately as required.
Appearance
Model
Y92E-J8S12
Applicable Sensors
E2E NEXT M8 Shielded Sensors
E2E NEXT M12 Shielded Sensors
E2E NEXT M18 Shielded Sensors
Y92E-J12S18
Y92E-J18S30
Note: Not applicable for E2EQ NEXT Series (spatter-resistant) models.
71
E2E/E2EQ NEXT Series
Ratings and Specifications
E2E NEXT Series (Triple distance model)
DC 2-wire
Size
Shielded
Model
M8
M12
M18
M30
Shielded
E2E-X3D@
3 mm ±10%
0 to 2.4 mm
Unshielded
Shielded
E2E-X7D@
7 mm ±10%
0 to 5.6 mm
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Item
E2E-X6MD@
E2E-X10MD@ E2E-X11D@ E2E-X20MD@ E2E-X20D@ E2E-X40MD@
Sensing distance
6 mm ±10%
0 to 4.8 mm
10 mm ±10%
0 to 8 mm
11 mm ±10%
0 to 8.8 mm
20 mm ±10%
0 to 16 mm
20 mm ±10%
0 to 16 mm
40 mm ±10%
0 to 32 mm
Setting distance *1
Differential travel
Detectable object
15% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 75.)
Iron,
9 × 9 × 1 mm
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
Standard sensing object
18 × 18 × 1 mm 21 × 21 × 1 mm 30 × 30 × 1 mm 33 × 33 × 1 mm 60 × 60 × 1 mm 60 × 60 × 1 mm 120 × 120 × 1 mm
Response frequency *2
Power supply voltage
Leakage current
350 Hz
250 Hz 350 Hz 200 Hz 250 Hz 200 Hz 200 Hz 50 Hz
10 to 30 VDC, (including 10% ripple (p-p))
0.8 mA max.
Load current
Control
3 to 100 mA
Residual
output
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m)
voltage
D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange)
Indicator
D1 Models: NO
D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 78 for details.
Operation mode
Protection circuits
Surge suppressor, Load short-circuit protection
Ambient temperature
range
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)
Operating and Storage: 35% to 95% (with no condensation)
Ambient humidity range
±20% max. of ±10% max. of
sensing
sensing
distance at
23°C in the
temperature
range of
distance at
23°C in the
temperature
range of
±20% max. of sensing distance
at 23°C in the temperature
range of -25 to 70°C
±10% max. of sensing distance at 23°C
in the temperature range of -25 to 70°C
Temperature influence
-25 to 70°C
-25 to 70°C
Voltage influence
Insulation resistance
Dielectric strength
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction)
500 m/s2 10 times each in X, Y,
1,000 m/s2 10 times each in X, Y, and Z directions
and Z directions
Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant
Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35 °C max.) and ISO 20653 (old
standard: DIN 40050 PART9) IP69K
Degree of protection
Connecting method
Pre-wired
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m)
Approx. 60 g
Approx. 70 g
Approx. 130 g Approx. 150 g Approx. 180 g Approx. 210 g
Models
Weight
(packed
state)
Pre-wired
Connector
Models
Approx. 30 g
Approx. 40 g
Approx. 70 g
Approx. 90 g
Approx.110 g Approx. 140 g
Nickel-plated
brass
Stainless steel
(SUS303)
Case
Nickel-plated brass
Sensing surface Polybutylene terephthalate (PBT)
Materials
Clamping nuts
Toothed washer Zinc-plated iron
Cable Vinyl chloride (PVC)
Accessories Instruction manual, Clamping nuts, Toothed washer
Nickel-plated brass
*1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
*3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.
*4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards.
2-year oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).
The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round Oil-resistant Connectors XS5 NEXT series correctly.
The degree of protection is not satisfied with the part where cable wires are uncovered for the Pre-wired Models.
72
E2E/E2EQ NEXT Series
E2EQ NEXT Series (Spatter-resistant Triple distance model)
DC 2-wire
Size
Shielded
Model
M8
M12
M18
M30
Shielded
Item
E2EQ-X3D@
E2EQ-X7D@
E2EQ-X11D@
E2EQ-X20D@
Sensing distance
Setting distance *1
Differential travel
Detectable object
Standard sensing object
Response frequency *2
Power supply voltage
Leakage current
3 mm ±10%
7 mm ±10%
0 to 5.6 mm
11 mm ±10%
0 to 8.8 mm
20 mm ±10%
0 to 16 mm
0 to 2.4 mm
15% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 75.)
Iron, 9 × 9 × 1 mm
250 Hz
Iron, 21 × 21 × 1 mm
250 Hz
Iron, 33 × 33 × 1 mm
250 Hz
Iron, 60 × 60 × 1 mm
200 Hz
10 to 30 VDC, (including 10% ripple (p-p))
0.8 mA max.
Load current
3 to 100 mA
Control output
Indicator
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m)
Residual voltage
D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange)
D1 Models: NO
D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 78 for details.
Operation mode
Protection circuits
Surge suppressor, Load short-circuit protection
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)
Operating and Storage: 35% to 95% (with no condensation)
Ambient temperature range
Ambient humidity range
±10% max. of sensing distance at 23°C
in the temperature range of -25 to 70°C
±20% max. of sensing distance at 23°C
in the temperature range of -25 to 70°C
Temperature influence
Voltage influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Insulation resistance
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance (destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10 times each in
Shock resistance (destruction)
1,000 m/s2 10 times each in X, Y, and Z directions
X, Y, and Z directions
Degree of protection
Connecting method
Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529) and IP67G *3 (JIS C 0920 Annex 1)
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m)
Pre-wired Models
Approx. 60 g
Approx. 70 g
Approx. 150 g
Approx. 210 g
Weight
(packed state)
Pre-wired Connector
Models
Approx. 30 g
Approx. 40 g
Approx. 90 g
Approx. 140 g
Case
Fluororesin coating (Base material: brass)
Fluororesin
Sensing surface
Clamping nuts
Toothed washer
Cable
Materials
Fluororesin coating (Base material: brass)
Zinc-plated iron
Vinyl chloride (PVC)
Accessories
Instruction manual, Clamping nuts, Toothed washer
*1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
*3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.
73
E2E/E2EQ NEXT Series
E2E NEXT Series (Single distance model)
DC 2-wire
Size
M8
M12
M18
Shielded
Shielded
Item
Model
E2E-X1R5D@
E2E-X2R5D@
E2E-X5D@
Sensing distance
Setting distance *1
Differential travel
Detectable object
Standard sensing object
Response frequency *2
Power supply voltage
Leakage current
1.5 mm ±10%
2.5 mm ±10%
0 to 2 mm
5 mm ±10%
0 to 4 mm
0 to 1.2 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 75.)
Iron, 10 × 10 × 1 mm
250 Hz
Iron, 12 × 12 × 1 mm
250 Hz
Iron, 18 × 18 × 1 mm
250 Hz
10 to 30 VDC, (including 10% ripple (p-p))
0.8 mA max.
Load current
3 to 100 mA
Control output
Indicator
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m)
Residual voltage
D1 Models: Operation indicator (orange), Setting indicator (green)
D2 Models: Operation indicator (orange)
D1 Models: NO
D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 78 for details.
Operation mode
Protection circuits
Surge suppressor, Load short-circuit protection
Ambient temperature range
Ambient humidity range
Temperature influence
Voltage influence
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)
Operating and Storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Insulation resistance
Dielectric strength
Vibration resistance (destruction)
500 m/s2 10 times each in X, Y, and Z
1,000 m/s2 10 times each in X, Y, and Z directions
directions
Shock resistance (destruction)
Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's
Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C
max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K
Degree of protection
Connecting method
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m)
Pre-wired Models
Weight
(packed state)
Approx. 60 g
Approx. 70 g
Approx. 130 g
Pre-wired Connector
Models
Approx. 30 g
Approx. 40 g
Approx. 70 g
Case
Stainless steel (SUS303)
Polybutylene terephthalate (PBT)
Nickel-plated brass
Nickel-plated brass
Sensing surface
Clamping nuts
Toothed washer
Cable
Materials
Zinc-plated iron
Vinyl chloride (PVC)
Accessories
Instruction manual, Clamping nuts, Toothed washer
*1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the
standard.
*3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.
*4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards.
2-year oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).
The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round Oil-resistant Connectors XS5 NEXT series correctly.
The degree of protection is not satisfied with the part where cable wires are uncovered for the Pre-wired Models.
74
E2E/E2EQ NEXT Series
Engineering Data (Reference Value)
Sensing Area
Triple distance model, Spatter-resistant Triple distance model
Shielded Models
Unshielded Models
E2E(Q)-X@D@
E2E-X@MD@
20
40
Y
E2E(Q)-X20D@30
E2E-X40MD@L30
X
35
Y
X
15
30
25
E2E(Q)-X11D@18
E2E-X20MD@L18
10
5
20
15
10
5
E2E(Q)-X7D@12
E2E-X10MD@12
E2E(Q)-X3D@8
E2E-X6MD@8
0
-15
0
-30
-10
-5
0
5
10
15
-20
-10
0
10
20
30
Distance Y (mm)
Distance Y (mm)
Single distance model
Shielded Models
E2E-X1R5D@/-X2R5D@/-X5D@
6
Y
E2E-X5D@
X
5
4
E2E-X2R5D@
3
2
1
0
E2E-X1R5D@
-10
-5
0
5
10
Distance Y (mm)
75
E2E/E2EQ NEXT Series
Influence of Sensing Object Size and Materials
Triple distance model, Spatter-resistant Triple distance model
Single distance model
Shielded Models
E2E-X1R5D@
Shielded Models
E2E(Q)-X3D@8
3 5
Unshielded Models
E2E-X6MD@8
7
2.5
@d
@d
@d
t =1 mm
Iron
t =1 mm
t =1 mm
X
6
5
4
3
2
1
0
X
3 0
X
Iron
2.0
2 5
2 0
1 5
1 0
0 5
0 0
Iron
Stainless steel
(SUS304)
1.5
1.0
0.5
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Brass
Brass
Aluminum
Brass
Aluminum
Copper
Copper
Aluminum
20
0
5
10
15
25
0
5
10
15
20
25
30
35
0
5
10
15
20
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
E2E(Q)-X7D@12
E2E-X10MD@12
E2E-X2R5D@
12
8
3.0
@d
@
d
@d
t =1 mm
Iron
t =1 mm
t =1 mm
Iron
X
X
7
6
5
4
3
2
1
0
Iron
X
10
8
2.5
Stainless steel
(SUS304)
Stainless steel
(SUS304)
2.0
1.5
1.0
0.5
Stainless steel
(SUS304)
6
Brass
Brass
Brass
4
Aluminum
Copper
Aluminum
Copper
Aluminum
2
0
0
10
20
30
40
50
60
0
5
10
15
20
25
30
0
10
20
30
40
50
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
E2E(Q)-X11D@18
E2E-X20MD@L18
E2E-X5D@
12
25
7
Iron
t =1 mm
@d
@d
@d
t =1 mm
t =1 mm
X
X
6
5
4
3
2
1
X
10
8
Iron
20
15
10
5
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Stainless steel
(SUS304)
6
Brass
Aluminum
Copper
Brass
Brass
4
Aluminum
Copper
Aluminum
2
0
0
0
10
20
30
40
50
0
20
40
60
80
100
0
10
20
30
40
50
60
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
E2E(Q)-X20D@30
E2E-X40MD@L30
45
25
@d
Iron
@d
t =1 mm
40
t =1 mm
X
X
Iron
20
15
10
5
35
30
25
20
15
10
5
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Brass
Brass
Aluminum
Copper
Aluminum
Copper
0
0
0
20
40
60
80
100
0
50
100
150
200
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
76
E2E/E2EQ NEXT Series
Leakage Current
Triple distance model, Spatter-resistant Triple distance model, Single distance model
E2E-X@(M)D@(-T)/E2EQ-X@D@(-T)
1.0
0.8
0.6
0.4
0.2
0
5
10
15
20
25
30
Power supply voltage (V)
Residual Output Voltage
Triple distance model, Spatter-resistant Triple distance model, Single distance model
E2E-X@(M)D@(-T)/E2EQ-X@D@(-T)
5
4
E2E-X@(M)D@-T/
E2EQ-X@D@-T
3
E2E-X@(M)D@/
E2EQ-X@D@
2
1
0
1
10
100
Load current (mA)
77
E2E/E2EQ NEXT Series
I/O Circuit Diagrams
DC 2-Wire Models
Operation
Model
Timing Chart
Output circuit
mode
Brown
Connector Pin
Arrangement
Load
1
10 to 30 VDC
Set position
Proximity
sensor
main
Non-
sensing
area
Unstable
sensing
area
Stable
sensing area
E2E(Q)-X@D1@
Proximity
Sensor
circuit
Blue
4
Sensing
object
Note: Pins 2 and 3
are not used.
0 V
Note: The load can be connected to either the +V or 0 V side.
(%)
100 80
0
Rated
sensing
distance
NO
Brown
Connector Pin
Arrangement
Setting
indicator
(green)
ON
4
3
Load
OFF
10 to 30 VDC (0V)
Proximity
sensor
main
Operation
indicator
(orange)
ON
circuit
OFF
E2E(Q)-X@D1@-T
E2E(Q)-X@D2@
E2E(Q)-X@D2@-T
Blue
0V (10 to 30 VDC)
Note: Pins 1 and 2
are not used.
ON
Control
output
OFF
Note1. The load can be connected to either the +V or 0 V side.
2. The E2E@-X@D1@(-M1TGJ)-T has no polarity. There is no need to be
concerned about the polarity of brown and blue wires, or pins 3 and 4.
Brown
Connector Pin
Arrangement
Load
1
10 to 30 VDC
Proximity
sensor
main
Non-sensing
area
Sensing area
Proximity
Sensor
circuit
Blue
2
Sensing
object
Note: Pins 3 and 4
are not used.
0 V
Note: The load can be connected to either the +V or 0 V side.
100
0
(%)
Brown
NC
Connector Pin
Arrangement
Rated
sensing
distance
1
2
Load
10 to 30 VDC (0V)
Proximity
sensor
main
Operation
indicator
(orange)
ON
OFF
circuit
ON
Control
output
Blue
0V (10 to 30 VDC)
OFF
Note: Pins 3 and 4
are not used.
Note1. The load can be connected to either the +V or 0 V side.
2. The E2E@-X@D1@(-M1TGJ)-T has no polarity. There is no need to be
concerned about the polarity of brown and blue wires, or pins 1 and 2.
78
E2E/E2EQ NEXT Series
Connections to Sensor I/O Connectors
Proximity Sensor
Sensor I/O Connector
Connections
Operation
mode
model number
Type
Polarity
Model
E2E/E2EQ NEXT Series
XS5
*
1
2
3
4
1
2
3
4
Brown (+)
E2E-X@D1@-M1TGJ
E2EQ-X@D1@-M1TGJ
White (not connected)
Blue (not connected)
Black ()
Yes
NO
NC
NO
NC
E2E/E2EQ NEXT Series
XS5
XS5F-D421-@80-X@
XS5F-D42@-@80-F
XS5W-D421-@81-X@
XS5W-D42@-@81-F
*
1
2
3
4
1
2
3
4
Brown (+)
E2E-X@D2@-M1TGJ
E2EQ-X@D2@-M1TGJ
No
White (−)
Blue (not connected)
Black (not connected)
DC 2-wire
(Smartclick
Connector)
Note: For details of the
connector, refer to
XS5 NEXT Series on
page 87.
E2E/E2EQ NEXT Series
XS5F
*
Brown (not connected)
1
2
3
4
1
2
3
4
E2E-X@D1@-M1TGJ-T
E2EQ-X@D1@-M1TGJ-T
Yes
No
White (not connected)
XS5 Series on
page 94.
Blue (+) (−)
Black (−) (+)
E2E/E2EQ NEXT Series
XS5F
*
1
2
3
4
1
2
3
4
Brown (+)(−)
E2E-X@D2@-M1TGJ-T
E2EQ-X@D2@-M1TGJ-T
White (−)(+)
Blue (not connected)
Black (not connected)
Note: Different from Proximity Sensor wire colors.
* If the XS5W Series Connector which has a socket and plug on the cable ends is connected to the Sensor, this part will be a plug.
79
E2E/E2EQ NEXT Series
Safety Precautions
Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/.
Warning Indications
Precautions for Safe Use
The following precautions must be observed to ensure safe operation.
Warning level
Indicates a potentially hazardous situation
1. Do not use the product in an environment where flammable or
which, if not avoided, will result in minor or
moderate injury, or may result in serious
injury or death. Additionally there may be
explosive gas is present.
WARNING
2. Do not attempt to disassemble, repair, or modify the product.
3. Do not use a voltage that exceeds the rated operating voltage
significant property damage.
range. Applying a voltage that is higher than the operating voltage
range may result in damage or burnout.
4. Be sure that the power supply polarity and other wiring is correct.
Incorrect wiring may cause explosion or burnout.
5. If the power supply is connected directly without a load, the
internal elements may explode or burn. Be sure to insert a load
when connecting the power supply.
Precautions for
Supplementary comments on what to do or
avoid doing, to use the product safely.
Safe Use
Supplementary comments on what to do or
avoid doing, to prevent failure to operate,
malfunction or undesirable effect on
product performance.
Precautions for
Correct Use
6. Dispose of this product as industrial waste.
Meaning of Product Safety Symbols
Precautions for Correct Use
General prohibition
Do not use this product under ambient conditions that exceed the
ratings.
● Operating Environment
Indicates the instructions of unspecified
prohibited action.
1. Do not install the product in the following locations.
Doing so may result in product failure or malfunction.
(1) Outdoor locations directly subject to sunlight, rain, snow, water
droplets, or oil.
Caution, explosion
Indicates the possibility of explosion under
specific conditions.
(2) Locations subject to atmospheres with chemical vapors, in
particular solvents and acids.
(3) Locations subject to corrosive gases.
WARNING
2. The Sensor may malfunction if used near ultrasonic cleaning
equipment, high-frequency equipment, transceivers, cellular
phones, inverters, or other devices that generate a high-frequency
electric field. Please refer to the Precautions for Correct Use on
the OMRON website (www.ia.omron.com) for typical measures.
3. Laying the Proximity Sensor wiring in the same conduit or duct as
high-voltage wires or power lines may result in incorrect operation
and damage due to induction. Wire the Sensor using a separate
conduit or independent conduit.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Risk of explosion.
Do not connect sensor to AC power supply.
4. Never use thinner or other solvents. Otherwise, the Sensor
surface may be dissolved.
5. The following conditions shall be observed if you use the product
under an environment using cutting oil that may affect product’s
life and/or performance.
• Usage under the cutting oil condition designated by the
specification
• Usage under the cutting oil dilution ratio recommended by its
manufacturer
• Usage in oil or water is prohibited
Impact on the product life may differ depending on the oil you use.
Before using the cutting oil, make sure that it should not cause
deterioration or degradation of sealing components.
80
E2E/E2EQ NEXT Series
● Design
● Mutual Interference
When the Proximity Sensor is embedded in metal, ensure that the
minimum distances given in the following table are maintained.
Influence of Surrounding Metal
When mounting the Proximity Sensor using a nut, only use the
provided nut. And ensure that the minimum distances given in the
following table are maintained.
L
L
B
A
(Unit: mm)
n
d dia.
m
Type
Item
M8
25
M12 M18 M30
D
m
Triple distance model/
Spatter-resistant Triple
distance model
A
40
30
70
45
140
70
*3
Shielded
(Unit: mm)
B
20
E2E(Q)-X@D@(-T)
Type
Item
L
M8
M12 M18 M30
A
B
A
B
80
60
20
15
120
100
30
200
120
50
380
280
Triple distance model
E2E-X@MD@(-T)
0
0
20
4
0
50
4
0
70
8
Unshielded
Shielded
Triple distance model/
Spatter-resistant Triple
distance model
E2E(Q)-X@D@(-T)
*1
d
20
2
Single distance model
E2E-X@R5D@(-T)
E2E-X5D@(-T)
Shielded
D
m
n
---
9
18
20
16
50
20
30
50
33
54
60
90
20
35
18
10
30
13
18
30
L
31 50 *3
● Mounting
Tightening Force
d
90
35
60
80
170
55
Triple distance model
E2E-X@MD@(-T)
*2
Unshielded
Shielded
D
m
n
Do not tighten the nut with excessive force.
A washer must be used with the nut.
120
140
Shielded Models
Unshielded Models
L
0
0
0
d
D
m
n
8
0
12
0
18
0
Single distance model
E2E-X@R5D@(-T)
E2E-X5D@(-T)
*2
---
Part B Part A
Part B Part A
4.5
12
8
20
27
Note: 1. The allowable tightening strength depends on the distance
from the edge of the head, as shown in the following table. (A
is the distance from the edge of the head. B includes the nut on
the head side. If the edge of the nut is in part A, the tightening
torque for part A applies instead.)
18
Note: Nuts that are supplied along with each Sensor (*1, *2) are
different. Refer to Dimensions for details on shapes.
*3. If you use the M30 Triple distance model of Unshielded Model, the
panel thickness (t) is 4 mm or less.
2. The following strengths assume washers are being used.
Triple distance model
When the Proximity Sensor is mounted in metal, ensure that the
minimum distances given in the following table are maintained.
Part A
Dimension(mm)
Part B
Model
Torque
Torque
I
Shielded
9
3
M8
4 N·m
10 N·m
15 N·m
60 N·m
80 N·m
Unshielded
Shielded
16
9
n
m
M12
M18
M30
6 N·m
15 N·m
40 N·m
d dia.
Unshielded
Shielded
D
16
3
m
I
Unshielded
Shielded
(Unit: mm)
23
8
Type
Item
I
M8
M12 M18 M30
Unshielded
2
4
20
4
4
50
4
8
70
Spatter-resistant Triple distance model
Triple distance model/
Spatter-resistant Triple
distance model
d
20
2
Part A
Model
Part B
Torque
10 N·m
15 N·m
30 N·m
80 N·m
Shielded
D
m
n
8
Dimension(mm)
Torque
4 N·m
9
18
20
20
50
20
30
50
33
54
35
90
35
60
80
60
E2E(Q)-X@D@(-T)
M8
9
18
13
30
13
18
30
90
M12
M18
M30
16
16
23
6 N·m
I
55
d
170
55
15 N·m
40 N·m
Triple distance model
E2E-X@MD@(-T)
Unshielded
D
m
n
120
140
Single distance model
Part A
Dimension(mm)
Part B
Torque
12 N·m
I
0
0
0
Model
Torque
d
8
0
12
0
18
0
Single distance model
E2E-X@R5D@(-T)
E2E-X5D@(-T)
M8
9
9 N·m
Shielded
D
m
n
---
M12
M18
30 N·m
70 N·m
---
4.5
12
8
20
27
18
81
E2E/E2EQ NEXT Series
Dimensions
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensors
E2E NEXT Series (Triple distance model)
DC 2-wire
Pre-wired Models
Shielded
Pre-wired Models
Unshielded
E2E-X3D@8
E2E-X6MD@8
37.8
37.8
4.4
4.4
33.4
33.4
15 dia.
15 dia.
6
20
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
26
3
8
4
10
13
13
4
1
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
Indicators *
Two clamping nuts
Toothed washer
Indicators *
Two clamping nuts
Toothed washer
M8 × P1
M8 × P1
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2E-X10MD@12
E2E-X7D@12
47.1
47.1
3.7
3.7
43.4
21 dia.
43.4
21 dia.
17
33
33
17
7
4-dia. vinyl-insulated round cable with
12
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
26
5.5
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
4
10
4
1
Indicators *
Two clamping nuts
Indicators *
M12 × P1
M12 × P1
Two clamping nuts
Toothed washer
Toothed washer
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2E-X11D@18
E2E-X20MD@L18
77.3
68.8
55.3
46.8
8.5
8.5
60
29 dia.
24
38
29 dia.
13
47
6-dia. vinyl-insulated round cable
6-dia. vinyl-insulated round cable
6
12
with 2 conductors (Conductor cross
24
4
with 2 conductors (Conductor cross
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 2 m
12
4
1
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 2 m
Indicators *
M18 × P1
Toothed washer
Indicators *
Two clamping nuts
D1 Models: Operation indicator (Orange), Setting indicator (Green)
Two clamping nuts
Toothed washer
M18 × P1
*
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
D2 Models: Operation indicator (Orange)
E2E-X40MD@L30
E2E-X20D@30
60.3
82.3
8.3
8.3
52
74
65
43
42 dia.
36
42 dia.
36
15
50
7
6-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 2 m
12
6-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 2 m
5
10
4
1
Indicators *
Two clamping nuts
Toothed washer
Indicators *
Two clamping nuts
Toothed washer
M30 × P1.5
M30 × P1.5
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
Mounting Hole Dimensions
Angle R of the Bending Wire
Wire pullout position
Sc
10 mm
R
(mm)
Sc
(mm)
Dimensions
M8
F (mm)
Dimensions
Dimensions
+0.5
0
8.5 dia.
12.5 dia.
18.5 dia.
30.5 dia.
M8
M8
+0.5
0
12
- (0)
M12
M12
M12
M18
M30
+0.5
0
R
M18
F
M18
+0.5
0
18
2.5
M30
M30
82
E2E/E2EQ NEXT Series
Pre-wired Connector Models
Shielded
Pre-wired Connector Models
Unshielded
E2E-X3D@8-M1TGJ
E2E-X6MD@8-M1TGJ
37.8
37.8
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 0.3 m
15 dia.
4.4
15 dia.
13
4.4
33.4
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 0.3 m
33.4
26
26
6
13
20
10
4
3
8
1
4
Indicators *
Two clamping nuts
Toothed washer
Indicators *
Two clamping nuts
Toothed washer
M12 × P1
M12 × P1
M8 × P1
M8 × P1
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2E-X10MD@12-M1TGJ
E2E-X7D@12-M1TGJ
47.1
3.7
43.4
21 dia.
17
47.1
21 dia.
17
3.7
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 0.3 m
4-dia. vinyl-insulated round cable with
2 conductors(Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 0.3 m
43.4
33
33
7
26
5.5
1
12
10
4
4
Indicators *
Indicators *
Two clamping nuts
Toothed washer
M12 × P1
M12 × P1
M12 × P1
M12 × P1
Two clamping nuts
Toothed washer
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2E-X11D@18-M1TGJ
E2E-X20MD@L18-M1TGJ
55.3
8.5
77.3
46.8
8.5
6-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 0.3 m
68.8
60
38
29 dia.
6-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG20, Insulator diameter: 1.5 mm),
Standard length: 0.3 m
29 dia.
12
6
13
47
4
24
24
4
12
1
Indicators *
Indicators *
M12 × P1
M12 × P1
M18 × P1
Two clamping nuts
Toothed washer
M18 × P1
Two clamping nuts
Toothed washer
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2E-X40MD@L30-M1TGJ
E2E-X20D@30-M1TGJ
82.3
8.3
60.3
74
8.3
6-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG20, Insulator diameter: 1.5 mm),
Standard length: 0.3 m
52
65
42 dia.
36
6-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross
section: AWG20, Insulator diameter:
1.5 mm), Standard length: 0.3 m
43
50
15
42 dia.
36
7
12
5 10
4
1
Indicators *
M12 × P1
M12 × P1
Indicators *
Two clamping nuts
Toothed washer
Two clamping nuts
Toothed washer
M30 × P1.5
M30 × P1.5
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
Mounting Hole Dimensions
Angle R of the Bending Wire
Wire pullout position
Sc
10 mm
R
(mm)
Sc
(mm)
Dimensions
M8
F (mm)
Dimensions
Dimensions
+0.5
0
8.5 dia.
12.5 dia.
18.5 dia.
30.5 dia.
M8
M8
+0.5
0
12
- (0)
M12
M12
M18
M30
M12
M18
M30
+0.5
0
R
M18
F
+0.5
0
18
2.5
M30
83
E2E/E2EQ NEXT Series
Sensors
E2EQ NEXT Series (Spatter-resistant Triple distance model)
DC 2-wire
Pre-wired Models
Shielded
E2EQ-X3D@8
E2EQ-X7D@12
47.1
37.8
15 dia.
4.4
43.4
33
21 dia.
17
3.7
4-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
33.4
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
26
13
5.5
4
8
10
1
1
Indicators *
Indicators *
Two clamping nuts
M8 × P1
Two clamping nuts
Toothed washer
M12 × P1
Toothed washer
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2EQ-X11D@18
E2EQ-X20D@30
60.3
55.3
52
43
8.3
46.8
38
8.5
29 dia.
24
42 dia.
36
6-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG20, Insulator diameter: 1.5 mm),
Standard length: 2 m
6-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG20, Insulator diameter: 1.5 mm),
Standard length: 2 m
7
12
6
12
1
1
Indicators
*
Indicators *
Two clamping nuts
Toothed washer
M18 × P1
Two clamping nuts
Toothed washer
M30 × P1.5
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
Pre-wired Connector Models
Shielded
E2EQ-X7D@12-M1TGJ
E2EQ-X3D@8-M1TGJ
47.1
21 dia.
3.7
4-dia. vinyl-insulated round cable with
2 conductors(Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 0.3 m
43.4
37.8
4-dia. vinyl-insulated round cable with
2 conductors(Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 0.3 m
15 dia.
33.4
4.4
17
33
26
5.5
13
4
10
8
1
1
Indicators *
Two clamping nuts
Toothed washer
Indicators *
Two clamping nuts
Toothed washer
M8 × P1
M12 × P1
M12 × P1
M12 × P1
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2EQ-X20D@30-M1TGJ
E2EQ-X11D@18-M1TGJ
60.3
55.3
52
8.3
8.5
6-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG20, Insulator diameter: 1.5 mm),
Standard length: 0.3 m
46.8
38
6-dia. vinyl-insulated round cable with
2 conductors(Conductor cross section:
AWG20, Insulator diameter: 1.5 mm),
Standard length: 0.3 m
42 dia.
43
29 dia.
36
7
12
6
1
12
24
1
Indicators*
Indicators *
Two clamping nuts
Toothed washer
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
M12 × P1
M18 × P1
Two clamping nuts
Toothed washer
M30 × P1.5
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
Mounting Hole Dimensions
Angle R of the Bending Wire
Wire pullout position
Sc
10 mm
R
(mm)
Sc
Dimensions
M8
F (mm)
Dimensions
Dimensions
(mm)
+0.5
0
8.5 dia.
12.5 dia.
18.5 dia.
30.5 dia.
M8
M8
- (0)
M12
+0.5
0
12
18
M12
M12
M18
M30
+0.5
0
R
M18
F
M18
2.5
+0.5
0
M30
M30
84
E2E/E2EQ NEXT Series
Sensors
E2E NEXT Series (Single distance model)
DC 2-wire
Pre-wired Models
Shielded
E2E-X1R5D@
E2E-X2R5D@
47
37.6
3.7
43.3
32.9
4.4
33.2
21 dia.
17
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
15 dia.
13
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 2 m
25.8
4
10
3
8
Indicators *
Two clamping nuts
Toothed washer
Indicators *
Two clamping nuts
* D1 Models: Operation indicator (Orange),
Setting indicator (Green)
D2 Models: Operation indicator (Orange)
M8 × P1
M12 × P1
* D1 Models: Operation indicator (Orange),
Setting indicator (Green)
D2 Models: Operation indicator (Orange)
Toothed washer
E2E-X5D@
54.3
8.5
45.8
29 dia.
24
37
6-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG20, Insulator diameter: 1.5 mm),
Standard length: 2 m
4
12
Indicators *
M18 × P1
* D1 Models: Operation indicator (Orange),
Setting indicator (Green)
D2 Models: Operation indicator (Orange)
Two clamping nuts
Toothed washer
Pre-wired Connector Models
Shielded
E2E-X2R5D@-M1TGJ
E2E-X1R5D@-M1TGJ
47
37.6
4-dia. vinyl-insulated round cable
with 2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 0.3 m
3.7
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG24, Insulator diameter: 1.05 mm),
Standard length: 0.3 m
4.4
43.3
21 dia.
17
33.2
15 dia.
32.9
25.8
4
10
3
8
13
Indicators *
Two clamping nuts
Toothed washer
Indicators *
Two clamping nuts
Toothed washer
M12 × P1
M8 × P1
M12 × P1
M12 × P1
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
E2E-X5D@-M1TGJ
54.3
8.5
6-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
AWG20, Insulator diameter: 1.5 mm),
Standard length: 0.3 m
45.8
37
29 dia.
4
12
24
Indicators *
Two clamping nuts
Toothed washer
M12 × P1
M18 × P1
* D1 Models: Operation indicator (Orange), Setting indicator (Green)
D2 Models: Operation indicator (Orange)
Mounting Hole Dimensions
Angle R of the Bending Wire
Wire pullout position
Sc
10 mm
R
(mm)
Sc
(mm)
Dimensions
M8
F (mm)
Dimensions
Dimensions
+0.5
0
8.5 dia.
12.5 dia.
18.5 dia.
30.5 dia.
M8
M8
+0.5
0
12
- (0)
2.5
M12
M12
M12
M18
M30
+0.5
0
R
M18
F
M18
+0.5
0
18
M30
M30
85
E2E/E2EQ NEXT Series
Accessories (Sold Separately)
e-jig (Mounting Sleeves)
Y92E-J12S18
Y92E-J8S12
35
23.3
28
3
3
18
26.8 dia.
24
19 dia.
26.8 dia.
24
4
4
21.2 dia.
19
17
M12 × 1
Sensor lock nut
Mounting Sleeve
M18 × 1
Two Mounting Sleeve
clamping nuts
Sensor lock nut
Mounting Sleeve
Two Mounting Sleeve
clamping nuts
M16×1
7
0.7
8.8
0.7
M20×1
8 dia.
A
A
12 dia.
Section A-A
A
A
Section A-A
Y92E-J18S30
Material
Polyetheretherketone (PEEK) /
40
Mounting Sleeve
5
23.2
Polybutylene terephthalate (PBT)
Polybutylene terephthalate (PBT)
Polybutylene terephthalate (PBT)
5
40 dia.
36
40.8 dia.
36
Mounting Sleeve
clamping nut
Sensor lock nut
Sensor lock O-ring
Material combining HNBR and fluororubber
M30 × 1.5
Sensor lock nut
Mounting Sleeve
Tightening Force
Two Mounting Sleeve
clamping nuts
Torque
11.9
M30 × 1.5
0.7
Model
Mounting Sleeve
Sensor lock nut
clamping nut
Y92E-J8S12
Y92E-J12S18
Y92E-J18S30
0.6 N·m
1.2 N·m
5 N·m
0.6 N·m
1.2 N·m
3.5 N·m
18 dia.
A
A
Section A-A
86
Round Oil-resistant Connectors (M12 Smartclick)
XS5 NEXT Series
RoundOil-resistiveSmartclickConnectors
for E2E NEXT Series proximity sensors,
that are Resistant to Oil,
and that Reduce Installation Work
• Uses unique OMRON technology*1 and the same PVC cable with
increased oil resistance as the E2E NEXT Series proximity sensors.
Oil-resistance performance values of 2 years*2 when used in
combination with E2E NEXT Series proximity sensors.
• Oil-resistant robot cables for use with moving parts such as
loaders and cableveyors
For the most recent information on models that have been
certified for safety standards, refer to your OMRON website.
• OMRON's unique lock mechanism (Smartclick) that is compatible
with round M12 connectors.
• Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
• A positive click indicates locking.
• IP67, IP69K degree of protection.
• UL approved products.
*1. Patent pending (as of July, 2018)
*2. Covered types of oil: Cutting oil specified in JIS K 2241:2000
The oil-resistance performance value (2 years) indicates the median value (=Typ) at product design, and in evaluation testing results of oil-
resistance performance. Shipped products will show some variance around this 2 year value in actual usage.
Features
Better Cable Oil Resistance, and Improved Overall Oil Resistance with New Rubber
Material in Mating Sections
The XS5 NEXT Series uses a special PVC cable that limits deterioration of the cable sheath due to both water-soluble and water-insoluble cutting oil.
Omron's proprietary molding technique prevents cutting oil intrusion from mating sections. Moreover, using the same new HNBR/fluoride rubber
as in oil-resistant components of connector mating sections helps improve the overall oil resistance.
Special PVC Cable +
Molding Sealing Method
Special
Smartclick Structure + O-ring
Smartclick
+ O-ring
Cable /
Molded
Seal
Unique Smartclick Structure
Cable sheath
(Special PVC cable)
Connector tabs
Blocked.
Cutting oil
O-ring Seal
Blocked. O-ring (New rubber material combining HNBR
Cutting oil
Plug
and fluororubber)
Socket
Cover
O-ring (New rubber material combining HNBR
and fluororubber)
Cutting oil
Patented
This new material combines the benefits of HNBR and fluororubber
New
Rubber
New Rubber Material Combining
and Fluororubber
Hydrogenated nitrile butadiene rubber (HNBR), which provides
superior resistance to oil, was blended with fluororubber in a unique
OMRON compound to develop a new rubber that provides superior
resistance to both swelling and deterioration due to cutting oil.
It is used in seals for joints and moving sections that prevent ingress
to prevent deterioration and destruction of the seal due to cutting oil,
resulting in increased oil resistance performance.
Material
Deterioration occurs less frequently,
but cutting oil causes swelling.
30
25
20
15
10
5
HNBR
Swelling occurs less frequently,
but cutting oil causes deterioration.
Fluororubber
New material
0
0
5
10
15
20
25
30
35
40
Deterioration (%)
87
XS5 NEXT Series
P67G quality and Omron's Oil Resistance Component Evaluation System
for two years of proven oil resistant capability
*
Oil resistance: 2 years
OMRON’s Oil-resistant Component
Evaluation Standards
Oil type
A1 (water-soluble cutting oil)
1,000 hours of machining
55 °C
Evaluation
time
IP67G
Oil type N3 (water-insoluble cutting oil)
Evaluation
Evaluation
48 hours
temperature
time
Evaluation
Room temperature
Dilution
temperature
Undiluted
concentration
Dilution
---
concentration
Appearance, performance,
and no label text loss
Criteria
Criteria
Appearance and performance
(Illustration)
(Illustration)
* Applicable oil types: specified in JIS K 2241:2000
“2-year oil resistance” refers to median values (=Typical values) of the product designs and the oil-resistance performance evaluation results.
Products to be shipped will have around 2 years of oil resistance; actual oil resistance will vary depending on the product.
Varied product lineup to suit the application
Fixed Parts
XS5@-D421-@8@-X
Moving Parts
XS5@-D421-@8@-XR
Installation with moving parts
such as loaders and cableveyors
Fixed installation
Model Number Structure
Model Number Legend
Use this legend when determining the product specifications from the model number. When ordering, use a model number from the table in
Ordering Information.
XS5@-D 4 2 1 - @ 8 @ - X@
1
2
3
4
5
6
7
8
9
1. Type
6. Cable Length
W: Connectors connected to cable, socket and plug on cable ends
F: Connectors connected to cable, socket on one cable end
2. Mating Section Form
C: 1 m
D: 2 m
E: 3 m
G: 5 m
D: A-coding (for DC sensor)
3. Connector Poles
J: 10 m
4: 4 poles
7. Connections (Numbers inside circles are terminal numbers)
8: A Brown, B White, C Blue, DBlack
8. Connectors on One End/Both Ends
0: Sockets on One Cable End
1: Socket and Plug on Cable Ends
9. Cable Specifications
4. Contact Plating
2: Gold plating
5. Cable Connection Direction
XS5W 1: Straight (Socket)/Straight (Plug)
XS5F 1: Straight
X: Oil-resistant PVC cable
XR: Oil-resistant PVC robot cable
is registered trademark of OMRON Corporation.
88
XS5 NEXT Series
Ordering Information
Connectors
Cable outer
diameter (mm)
Type
Cable specifications
Cable length (m)
Model
UL
1
2
XS5W-D421-C81-X
XS5W-D421-D81-X
XS5W-D421-E81-X
XS5W-D421-G81-X
XS5W-D421-J81-X
XS5W-D421-C81-XR
XS5W-D421-D81-XR
XS5W-D421-E81-XR
XS5W-D421-G81-XR
XS5W-D421-J81-XR
XS5F-D421-C80-X
XS5F-D421-D80-X
XS5F-D421-E80-X
XS5F-D421-G80-X
XS5F-D421-J80-X
XS5F-D421-C80-XR
XS5F-D421-D80-XR
XS5F-D421-E80-XR
XS5F-D421-G80-XR
XS5F-D421-J80-XR
6 dia.
Oil-resistant PVC cable
3
5
10
1
Socket and Plug
on Cable Ends
2
6 dia.
6 dia.
Oil-resistant PVC robot cable
Oil-resistant PVC cable
3
5
10
1
UL2238 certified
(File no. E207683)
2
3
5
10
1
Sockets on One
Cable End
2
6 dia.
Oil-resistant PVC robot cable
3
5
10
Accessories (Sold Separately)
Connector Covers
Water-resistive Covers
Suitable connector
Model Mounting portion
Model
Material
Remarks
This provides IP67 levels of protection.
When mounting the Water-resistive Cover to a
Connector, be sure to apply a torque range between
0.39 and 0.49 N·m to tighten the Water-resistive Cover.
XS2Z-11
Brass/nickel plated
XS5W
M12 male screw
This provides IP67 levels of protection.
This uses the Smart click mechanism. There’s no need
to keep track of locking torque.
XS5Z-11
PBT
XS5F/XS5W
M12 female screw
Water-resistive Covers
XS2Z-11
XS5Z-11
M12 female screw
XS5Z-11
M12 male screw
XS2Z-11
M12×1
Dust Covers
Model
Suitable connector
Material
Remarks
Model
XS5W
Mounting portion
XS2Z-13
XS2Z-14
XS2Z-15
M12 male screw
The Dust Cover is for dust prevention and does not
ensure IP67 degree of protection.
When mounting the Dust Cover to a connector, be sure
to press the Dust Cover onto the Connector until the
Connector is fully inserted into the Dust Cover.
Contact blocks
(female contact)
Rubber/black
XS5F/XS5W
M12 female screw
Dust Covers
XS2Z-13
XS2Z-15/XS2Z-14
M12 male screw
M12 female screw
XS2Z-13
XS2Z-15
XS2Z-14
Contact blocks (female contact)
89
XS5 NEXT Series
Ratings and Specifications
Rated current
4 A
Rated voltage
250 VDC
Contact resistance (connector)
Insulation resistance
Dielectric strength (connector)
40 mΩ max. (at 20 mV max., 100 mA max.)
1,000 MΩ min. (at 500 VDC) *1
1,500 VAC for 1 minute (leakage current: 1 mA max.)
IP67 (IEC60529)
IP69K (ISO20653 (formerly DIN Standard 40050 PART9))
OMRON’s Oil-resistant Component Evaluation Standards *2
(Cutting oil type JIS K 2241:2000-specification cutting oil, at 35°C or below)
Degree of protection
Insertion tolerance
Lock strength
50 times
Tensile: 100 N/15 s, Torsion: 1 N·m/15 s
Tensile: 100 N/15 s, Torsion: 1 N·m/15 s
0.1 to 0.25 N·m
Cable holding strength
Lock operating force
Ambient operating temperature range -25 to +70°C *3
Ambient humidity range
20 to 85%RH
*1. State at shipping.
*2. “OMRON’s Oil-resistant Component Evaluation Standards” are OMRON’s own durability evaluation standards.
Protection performance with oil-resistive connector (XS5F/W-X) correctly mated.
This performance does not apply if an oil-resistive connector (XS5F/W-X) is missing, and cord wiring is exposed.
*3. Use the robot cable within a temperature range of 0 to 70°C to avoid the wire breakage when moving.
Materials and Finishes
Model
XS5F/W-X
XS5F/W-XR
Item
Oil-resistant PVC cable
Oil-resistant PVC robot cable
Contacts
Fixtures
Fixtures (Lock) *
Pin block
O-ring
Copper alloy/Gold plating
Zinc alloy/Nickel plating
Stainless
PBT resin
Material combining HNBR and fluororubber
PBT resin
Cover
UL 758 (AWM) 6 mm dia.
AWG20
UL 758 (AWM) 6 mm dia.
AWG21
Cable
* Only plug
Connector Pinout Diagram (from Mating Side)
Item
No. of poles
4 poles
1
4
Male (plug)
contacts
2
3
A-coding
(For DC
sensors)
2
Female(socket)
contacts
1
3
4
90
XS5 NEXT Series
Connection Combinations
Plug
Smartclick Plug Connectors
M12 Plug Connectors
XS5H, XS5G,
XS5W (plug side),
XS5R (plug side), XS5M *
XS2H, XS2G,
XS2W (plug side),
XS2R (plug side), XS2M *
Socket
OMRON model No.
XS5F, XS5C
Smartclick Socket
Connectors
XS5W (socket side),
XS5R (socket side),
XS5P *
XS2F, XS2C,
XS2W (socket side),
XS2R (socket side),
XS2P *
M12 Socket Connectors
* XS2P/XS5P and XS5M, XS2M cannot mate with each other.
Note: : Connected by twisting.
: Connected by screwing.
Dimensions
(Unit: mm)
Both end connector type
XS5W-D421-□81-X
XS5W-D421-□81-XR
L (Cable Length)
44.7
40.7
2
1
4
6 dia.
4
3
2
14.9 dia.
3
1
M12×1
M12×1
Cover (Black)
Cover (Black)
Wiring Diagram for 4 Cores
Pin No.
Cable color of
core sheath
1
2
3
4
1
Brown
2 White
3 Blue
4
Black
One end connector type
XS5F-D421-□80-X
XS5F-D421-□80-XR
L (Cable Length)
40.7
2
1
4
6 dia.
14.9 dia.
3
30
5
Cover (Black)
M12×1
50
Wiring Diagram for 4 Cores
Pin No.
Cable color of
core sheath
1
2
3
4
1
Brown
2 White
3 Blue
4
Black
91
XS5 NEXT Series
Safety Precautions
Meaning of Display
Precautions for Correct Use
Precautions for
• Do not use the Connectors in an atmosphere or environment that
exceeds the specifications.
Supplementary comments on what to do
or avoid doing, to use the product safely.
Safe Use
• Always turn OFF the power supply before wiring. Failure to turn OFF
the power supply may lead to electric shock or damage to devices.
• As usage in environments in which cutting oil is used may impact service
life and performance, ensure the following requirements are met.
• Usage with cutting oil requirements as defined in specifications.
• Usage at a dilution ratio as recommended by cutting oil manufacturers.
• Usage immersed in oil or water is prohibited.
Supplementary comments on what to do
or avoid doing, to prevent failure to
operate, malfunction, or undesirable
effects on product performance.
Precautions for
Correct Use
Precautions for Safe Use
The cutting oil used may have a different impact on product service
life. Ensure that the product is used only after confirming with the
customer that there has been no deformation or deterioration of
seal material from the cutting oil.
• The mating coupler will impact the oil-resistance performance
values (years). Confirm mating of the couplers before use.
Degree of Protection
Do not use the product if its protective capabilities have been
compromised, such as through swelling or cracks to housing or seal
materials.
If products in this state continue to be used, then cutting oil or other
contaminants may enter the product, leading to breakages or damage
from fire.
Mating Combinations
Other XS5/
Connector Connection and Disconnection
• When connecting or disconnecting Connectors, be sure to hold the
Connectors by hand.
XS5@R
XS5@-X/XR
XS2 Series
Oil-resistance
performance
values
Oil-resistance
performance
values
• Do not hold the cable when disconnecting Connectors.
Check the alignment using the slot in the polarity key.
• Do not wiring the Connector when your hands are wet. Malfunctions
or device damage may occur when power is supplied to a device.
• When mating Connectors, be sure to insert the plug all the way to the
back of the socket before attempting to lock the Connectors.
After you lock a Connector, always confirm that it is mated properly.
• Do not use tools of any sort to mate the Connectors. Always use
your hands. Pliers or other tools may damage the Connectors.
• When you replace a Connector, make sure that there is no liquid,
cutting oil, or other foreign matter on the mating surfaces before
you mate the Connector.
XS5@R
Water-resistance
4 years
2 years
Oil-resistance
performance
values
Oil-resistance
performance
values
XS5@-X/XR
Water-resistance
Water-resistance
2 years
2 years
Other
XS5/XS2
Series *
Water-
resistance
Water-
resistance
* Oil-resistant (polyurethane) cable products (XS5F-P, XS5H-P,
XS5W-P) as well as oil-resistant (polyurethane) robot cables
(XS5F-PR, XS5W-PR) are excluded. Please consult with OMRON
for details of these products.
Disposal
• Environments with corrosive gases and high temperature and
humidity can cause bad connections and damage through
corrosion, leading to degraded performance, therefore do not use
these products in such environments.
Dispose of this product as industrial waste.
• Do not pull on the Connectors or cables with excessive force.
• Do not step on or place any objects on the Connectors. Doing so
may damage the Connectors.
• Lay the cable where it will not be stepped on to prevent the wires
in the cable from being disconnected and to protect the Connectors
from being damaged. If the cable must be placed where it will be
stepped on, install a protective cover.
• At installation, if not installing sensors or switches, and not mating
plug connectors, then use water-resistant covers (XS5Z-11, XS2Z-
11) or dust-resistant covers (XS2Z-13/14/15) in order to ensure
correct connector mating.
Wiring
• Do not wire cables in environments in which the cable terminal
sections will be subject to fluids such as water or cutting oil.
• When wiring cables, ensure this is carried out in accordance with
the wiring diagram.
• Lay the cables so that external force is not applied to the
Connectors. Otherwise, the degree of protection (IP67G) may not
be achieved.
Degree of Protection (IP67)
• The degree of protection of Connectors (IP67) is not for a fully
watertight structure. Do not use the Connectors underwater.
• Do not step on or place any objects on the Connectors. Doing so
may damage the Connectors.
92
XS5 NEXT Series
Setup
• Do not install the Connectors with a load placed directly on the joint
or at the point where the wires connect to the Connector.
The Connector may be damaged or the wires in the cable may be
disconnected.
• If bending cables, ensure that these use a minimum bend radius of
40 mm.
Please do not bend
from the root portion on the cable
Providing a straight section
from the root portion on the cable
The radius of
40 mm or more
Connecting
1. Connecting the XS5 Plug and Socket
2. Connecting the XS5 and XS2
• Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
• Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
• In the same way as when connecting two XS2 Connectors, screw
the knurled grip in the clockwise direction.
• When mating the products to XS2 or other M12 Connectors,
Polarity key
Protrusion on
cover aligns with
polarity key.
tighten the lock to a torque of 0.39 to 0.49 N
-m.
• Hold the knurled socket grip, then insert the projection on the plug
into the groove of the socket.
Socket
Plug
Fixtures (grip)
• Turn the knurled grips of the socket clockwise approximately 1/8
turn in respect to the plug. A click will indicate that the Connectors
are locked. The locking condition can also be confirmed by the
alignment marks on the plug and socket.
Alignment marks
93
Round Water-resistant Connectors (M12 Smartclick)
XS5
Round Water-resistive Smartclick
Connectors for E2E NEXT Series
proximity sensors that
Reduce Installation Work
• A newly developed lock mechanism that is compatible
with round M12 connectors.
• Simply insert the Connectors, then turn them
approximately 1/8 of a turn to lock.
• A positive click indicates locking.
• IP67 degree of protection.
• UL approved products.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
page 100.
Model Number Structure
Model Number Legend
Use this legend when determining the product specifications from the model number. When ordering, use a model number from the table in
Ordering Information.
XS5@-D 4 2 @ - @ 8 @ - F
1
2
3
4
5
6
7
8
9
1. Type
6. Cable Length
C: 1 m
W: Connectors connected to cable, socket and plug on cable ends
F: Connectors connected to cable, socket on one cable end
D: 2 m
E: 3 m
G: 5 m
J: 10 m
2. Mating Section Form
D: A-coding (for DC sensor)
3. Connector Poles
7. Connections (Numbers inside circles are terminal numbers)
8: ABrown, BWhite, CBlue, DBlack
4: 4 poles
4. Contact Plating
2: Gold plating
8. Connectors on One End/Both Ends
0: Sockets on One Cable End
5. Cable Connection Direction
XS5W
1: Socket and Plug on Cable Ends
1: Straight (Socket)/Straight (Plug)
2: Right-angle (Socket)/Right-angle (Plug)
3: Straight (Socket)/Right-angle (Plug)
4: Right-angle (Socket)/Straight (Plug)
9. Cable Specifications
F: Robot cable
XS5F
1: Straight
2: Right-angle
is registered trademark of OMRON Corporation.
94
XS5
Ordering Information
Connectors
Cable outer
diameter
(mm)
Cable
length (m)
Type
Cable Connection Direction
Model
UL
1
2
XS5W-D421-C81-F
XS5W-D421-D81-F
XS5W-D421-E81-F
XS5W-D421-G81-F
XS5W-D421-J81-F
XS5W-D422-D81-F
XS5W-D422-G81-F
XS5W-D423-D81-F
XS5W-D423-G81-F
XS5W-D424-D81-F
XS5W-D424-G81-F
XS5F-D421-C80-F
XS5F-D421-D80-F
XS5F-D421-E80-F
XS5F-D421-G80-F
XS5F-D421-J80-F
XS5F-D422-C80-F
XS5F-D422-D80-F
XS5F-D422-E80-F
XS5F-D422-G80-F
XS5F-D422-J80-F
Straight (Socket)/Straight (Plug)
3
5
10
2
Socket and Plug
on Cable Ends
XS5W
6 dia.
Right-angle (Socket)/Right-angle (Plug)
Straight (Socket)/Right-angle (Plug)
Right-angle (Socket)/Straight (Plug)
5
2
5
2
UL2238 certified
(File no.
5
E207683)
1
2
Straight type
3
5
Sockets on One
Cable End
XS5F
10
1
6 dia.
2
Right-angle type
3
5
10
95
XS5
Accessories (Sold Separately)
Connector Covers
Water-resistive Covers
Suitable connector
Model Mounting portion
Model
Material
Remarks
This provides IP67 levels of protection.
Brass/
Nickel plated
When mounting the Water-resistive Cover to a Connector, be sure to
apply a torque range between 0.39 and 0.49 N·m to tighten the Water-
resistive Cover.
XS2Z-11
XS5W
M12 male screw
This provides IP67 levels of protection.
M12 female screw This uses the Smart click mechanism. There’s no need to keep track
of locking torque.
XS5Z-11
PBT
XS5F/XS5W
Water-resistive Covers
XS2Z-11
XS5Z-11
M12 female screw
XS5Z-11
M12 male screw
XS2Z-11
M12×1
Dust Covers
Suitable connector
Model
Material
Remarks
Model
XS5W
Mounting portion
XS2Z-13
XS2Z-14
XS2Z-15
M12 male screw
The Dust Cover is for dust prevention and does not ensure IP67
degree of protection.
When mounting the Dust Cover to a connector, be sure to press the
Dust Cover onto the Connector until the Connector is fully inserted
into the Dust Cover.
Contact blocks
(female contact)
Rubber/Black
XS5F/XS5W
M12 female screw
Dust Covers
XS2Z-13
XS2Z-15/XS2Z-14
M12 male screw
M12 female screw
XS2Z-13
XS2Z-15
XS2Z-14
Contact blocks (female contact)
96
XS5
Ratings and Specifications
Rated current
4 A
Rated voltage
250 VDC
Contact resistance (connector)
Insulation resistance
Dielectric strength (connector)
Degree of protection
Insertion tolerance
40 mΩ max. (at 20 mV max., 100 mA max.)
1,000 MΩ min. (at 500 VDC) *1
1,500 VAC for 1 minute (leakage current: 1 mA max.)
IP67 (IEC 60529)
50 times
Lock strength
Tensile: 100 N/15 s, Torsion: 1 N·m/15 s
Tensile: 100 N/15 s, Torsion: 1 N·m/15
0.1 to 0.25 N·m
Cable holding strength
Lock operating force
Ambient operating temperature range -25 to 70°C *2
Ambient humidity range
20 to 85%RH
*1. State at shipping.
*2. Use the robot cable within a temperature range of 0 to 70°C to avoid the wire breakage when moving.
Materials and Finishes
Connector Pinout Diagram
(from Mating Side)
Model
XS5W/XS5F
Item
Item
No. of poles
4 poles
Contacts
Fixtures
Pin block
O-ring
Copper alloy/Gold plating
Zinc alloy/Nickel plationg
PBT resin
1
4
Male (plug)
contacts
2
3
A-coding
(For DC
sensors)
Rubber
Cover
PBT resin
2
Female(socket)
contacts
UL13 (CL3), UL758 (AWM), 6 mm dia.,
AWG20
Cable
1
3
4
Connection
Plug
Smartclick Plug Connectors
M12 Plug Connectors
XS5H, XS5G,
XS5W (plug side),
XS5R (plug side), XS5M *
XS2H, XS2G,
XS2W (plug side),
XS2R (plug side), XS2M *
Socket
OMRON model No.
XS5F, XS5C
Smartclick Socket
Connectors
XS5W (socket side),
XS5R (socket side),
XS5P *
XS2F, XS2C,
XS2W (socket side),
XS2R (socket side),
XS2P *
M12 Socket Connectors
* XS2P/XS5P and XS5M, XS2M cannot mate with each other.
Note: : Connected by twisting.
: Connected by screwing.
97
XS5
Dimensions
(Unit: mm)
Socket and Plug on Cable Ends XS5W
Straight (Socket)/straight (Plug)
XS5W-D421-@81-F
M12×1
1
2
3
4
3
14.9 dia.
14.9 dia.
2
1
4
40.7
44.7
M12×1.0
L (Cable Length)
Right-angle (Socket)/right-angle (Plug)
XS5W-D422-@81-F
L (Cable Length
)
25.3
25.3
28.3
32.3
M12×1
14.9 dia.
14.9 dia.
2
3
4
3
2
1
Wiring Diagram for 4 Cores
1
4
Pin No.
Cable color of
core sheath
M12×1.0
1
2
3
4
1
Brown
2 White
3 Blue
Straight (Socket)/right-angle (Plug)
XS5W-D423-@81-F
4
Black
L (Cable Length
)
40.7
25.3
1
2
3
14.9 dia.
4
32.3
M12×1.0
M12×1
14.9 dia.
2
3
1
4
Right-angle (Socket)/straight (Plug)
XS5W-D424-@81-F
L (Cable Length
)
44.7
25.3
4
3
14.9 dia.
2
1
28.3
M12×1
14.9 dia.
3
4
2
1
M12×1.0
98
XS5
Sockets on One Cable End XS5F
Straight type
XS5F-D421-@80-F
L (Cable Length)
40.7
1
2
3
14.9 dia.
4
30
5
Wiring Diagram for 4 Cores
M12×1.0
50
Cable color of
core sheath
Pin No.
Right-angle type
XS5F-D422-@80-F
1
Brown
White
Blue
1
2
3
4
2
3
4
Black
L (Cable Length
)
25.3
28.3
30
5
50
14.9 dia.
3
4
2
1
M12×1.0
99
XS5
Safety Precautions
Wiring
Meaning of Display
• Do not wire cables in environments in which the cable terminal
sections will be subject to fluids such as water or cutting oil.
• When wiring cables, ensure this is carried out in accordance with
the wiring diagram.
• Lay the cables so that external force is not applied to the
Connectors. Otherwise, the degree of protection (IP67G) may not
be achieved.
Precautions for
Supplementary comments on what to do
or avoid doing, to use the product safely.
Safe Use
Supplementary comments on what to do
or avoid doing, to prevent failure to
operate, malfunction, or undesirable
effects on product performance.
Precautions for
Correct Use
Degree of Protection (IP67)
• The degree of protection of Connectors (IP67) is not for a fully
watertight structure. Do not use the Connectors underwater.
• Do not step on or place any objects on the Connectors. Doing so
may damage the Connectors.
Precautions for Safe Use
Degree of Protection
Do not use the product if its protective capabilities have been
compromised, such as through swelling or cracks to housing or seal
materials.
Setup
Breakages or damage from fire may occur when products in this state
continue to be used.
• Do not install the Connectors with a load placed directly on the joint
or at the point where the wires connect to the Connector.
The Connector may be damaged or the wires in the cable may be
disconnected.
• If bending cables, ensure that these use a minimum bend radius of
40 mm.
Connector Connection and Disconnection
• When connecting or disconnecting Connectors, be sure to hold the
Connectors by hand.
• Do not hold the cable when disconnecting Connectors.
Check the alignment using the slot in the polarity key.
• Do not wiring the Connector when your hands are wet. Malfunctions
or device damage may occur when power is supplied to a device.
• When mating Connectors, be sure to insert the plug all the way to the
back of the socket before attempting to lock the Connectors.
After you lock a Connector, always confirm that it is mated properly.
• Do not use tools of any sort to mate the Connectors. Always use
your hands. Pliers or other tools may damage the Connectors.
• When you replace a Connector, make sure that there is no liquid,
cutting oil, or other foreign matter on the mating surfaces before
you mate the Connector.
Please do not bend
from the root portion on the cable
Disposal
Dispose of this product as industrial waste.
Providing a straight section
from the root portion on the cable
Precautions for Correct Use
• Do not use the Connectors in an atmosphere or environment that
exceeds the specifications.
• Always turn OFF the power supply before wiring. Failure to turn OFF
the power supply may lead to electric shock or damage to devices.
• Environments with corrosive gases and high temperature and
humidity can cause bad connections and damage through
corrosion, leading to degraded performance, therefore do not use
these products in such environments.
The radius of
40 mm or more
• Do not pull on the Connectors or cables with excessive force.
• Do not step on or place any objects on the Connectors. Doing so
may damage the Connectors.
• Lay the cable where it will not be stepped on to prevent the wires
in the cable from being disconnected and to protect the Connectors
from being damaged. If the cable must be placed where it will be
stepped on, install a protective cover.
• At installation, if not installing sensors or switches, and not mating
plug connectors, then use water-resistant covers (XS5Z-11, XS2Z-
11) or dust-resistant covers (XS2Z-13/14/15) in order to ensure
correct connector mating.
100
XS5
Connecting
1. Connecting the XS5 Plug and Socket
• Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
Polarity key
Protrusion on
cover aligns with
polarity key.
• Hold the knurled socket grip, then insert the projection on the plug
into the groove of the socket.
Socket
Plug
Fixtures (grip)
• Turn the knurled grips of the socket clockwise approximately 1/8
turn in respect to the plug. A click will indicate that the Connectors
are locked. The locking condition can also be confirmed by the
alignment marks on the plug and socket.
Alignment marks
2. Connecting the XS5 and XS2
• Align the projection on the plug cover with the polarity key on the
socket, then insert the plug all the way in.
• In the same way as when connecting two XS2 Connectors, screw
the knurled grip in the clockwise direction.
• Use your fingers to tighten the Connectors sufficiently.
101
Round Water-resistant Connectors (M8)
XS3W-M8/XS3F-M8
Small Round Water-resistive
Connectors
• Water-resistive, compact connector meets IP67
requirements.
• M8 Screw-on Connectors
• Connectors on both cable ends require no harness
work.
• Compliant with IEC61076-2-104
• UL approved products.
Refer to Safety Precautions on page 106.
Model Number Structure
Model Number Legend
Use this model number legend to identify products from their model number. Use this model number legend to identify products from their model
number. When ordering, use a model number from the table in Ordering Information.
XS3@ - M 8 P V C @ @ @
3
1
2
5
6
4
1. Type
5. Cable Connection Direction
XS3W-M8
W: Socket and Plug on Cable Ends
F: Sockets on One Cable End
SS: Straight (Plug)/Straight (Socket)
SA: Straight (Plug)/Right-angle (Socket)
2. Fastening Method
XS3F-M8
S: Straight
A: Right-angle
M8: M8 type
3. Cable Material
PVC: PVC Cable
6. Cable Length
2M: 2 m
4. Connector Poles
3: 3 poles
5M: 5 m
10M: 10 m
4: 4 poles
102
XS3W-M8/XS3F-M8
Ordering Information
Cable
specifications
Cable outer
diameter (mm)
No. of cable
cores (Poles)
Cable connection
direction
Cable length
(m)
Type
Model
UL
2
5
XS3W-M8PVC3SS2M
XS3W-M8PVC3SS5M
XS3W-M8PVC3SS10M
XS3W-M8PVC3SA2M
XS3W-M8PVC3SA5M
XS3W-M8PVC3SA10M
XS3W-M8PVC4SS2M
XS3W-M8PVC4SS5M
XS3W-M8PVC4SS10M
XS3W-M8PVC4SA2M
XS3W-M8PVC4SA5M
XS3W-M8PVC4SA10M
XS3F-M8PVC3S2M
XS3F-M8PVC3S5M
XS3F-M8PVC3S10M
XS3F-M8PVC3A2M
XS3F-M8PVC3A5M
XS3F-M8PVC3A10M
XS3F-M8PVC4S2M
XS3F-M8PVC4S5M
XS3F-M8PVC4S10M
XS3F-M8PVC4A2M
XS3F-M8PVC4A5M
XS3F-M8PVC4A10M
Straight (Plug)/
Straight (Socket)
10
2
3
4
3
4
Straight (Plug)/
Right-angle (Socket)
5
10
2
Socket and Plug
on Cable Ends
Straight (Plug)/
Straight (Socket)
5
10
2
Straight (Plug)/
Right-angle (Socket)
5
UL2238
certified
(File no.
E207683)
10
2
PVC cable
5.0 dia.
Straight type
5
10
2
Right-angle type
Straight type
5
10
2
Sockets on One
Cable End
5
10
2
Right-angle type
5
10
Ratings and Specifications
Item
Model
XS3W-M8/XS3F-M8
Rated current
Rated voltage
1 A
125 VDC
Contact resistance (connector) 40 mΩ max. (20 mV max., 100 mA max.)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength (connector) 1,000 VAC for 1 min (leakage current: 1 mA max.)
Degree of protection
Insertion tolerance
Cable tensile strength
IP67 (IEC60529)
200 times
49 N/15 s
Ambient operating temperature
range
-10 to 80°C
Ambient humidity range
20 to 85%RH
Materials and Finish
Pin Arrangement (Engaged Side)
Item
Model
XS3W-M8/XS5F-M8
Copper alloy/Gold plating
Copper alloy/Nickel plating
PBT resin
Item
Poles
3 poles
4 poles
Contacts
Fixture
Contact block
O-ring
4
2
1
4
Male (plug)
1
3
3
contacts
DC
Rubber
4
Cover
PBT resin
4
3
2
Female(socket)
contacts
3
1
1
Cable
5 mm dia, AWG23, PVC
103
XS3W-M8/XS3F-M8
Dimensions
(Unit: mm)
Connectors on both cable ends XS3W-M8
Straight (Plug)/Straight (Socket)
XS3W-M8PCV3SS@M (3 poles)
L
32
31.4
4
4
10 dia.
9 dia.
1
3
3
1
M8×1
M8×1
XS3W-M8PCV4SS@M (4 poles)
L
32
31.4
4
2
4
3
2
10 dia.
9 dia.
3
1
1
M8×1
M8×1
Straight (Plug)/Right-angle (Socket)
XS3W-M8PCV3SA@M (3 poles)
L
32
23.1
4
10 dia.
3
1
20.5
M8×1
9 dia.
3
4
1
M8×1
XS3W-M8PCV4SA@M (4 poles)
L
32
23.1
4
3
2
10 dia.
1
20.5
M8×1
9 dia.
3
4
1
2
M8×1
Wiring Diagram
3 Cores
4 Cores
Pin No.
Cable lead colors
Pin No.
Cable lead colors
1
2
1
2
1
1
Brown
White
Blue
Brown
3
4
3
4
3
4
3
Blue
Black
4
Black
104
XS3W-M8/XS3F-M8
Connectors on both cable ends XS3F-M8
Straight Connectors
XS3F-M8PCV3S@M (3 poles)
L
31.4
4
9 dia.
3
1
5
30
M8×1
50
XS3F-M8PCV4S@M (4 poles)
L
31.4
4
2
1
9 dia.
3
5
30
M8×1
50
Right-Angle Connectors
XS3F-M8PCV3A@M (3 poles)
L
23.1
5
20.5
30
50
9 dia.
1
4
3
M8×1
XS3F-M8PCV4A@M (4 poles)
L
23.1
5
20.5
30
50
9 dia.
2
4
1
3
M8×1
Wiring Diagram
3 Cores
4 Cores
Wiring Diagram
Wiring Diagram
Pin No.
Cable lead colors
Pin No.
Cable lead colors
Brown
1
2
3
4
Brown
White
Blue
1
3
4
Blue
Black
Black
105
XS3W-M8/XS3F-M8
Safety Precautions
Degree of Protection
Meaning of Display
• Do not impose external force continuously on the joints of pin
blocks and covers, otherwise the Connectors may not keep its
proper degree of protection (i.e., IP67).
• The degree of protection of connectors (IP67) is not for a fully
watertight structure. Do not use them underwater.
• The Connectors are not oil-resistant. Do not use them where they
would be subject to oil.
Supplementary comments on what to
do or avoid doing, to use the product
safely.
Precautions for
Safe Use
Supplementary comments on what to
do or avoid doing, to prevent failure to
operate, malfunction, or undesirable
effects on product performance.
Precautions for
Correct Use
• If Connectors are used in places with vibration or shock, secure the
mating section of each Connector, otherwise the Connectors may
be disconnected or fail to maintain their proper degree of
protection.
• Connectors are of resin mold construction. Do not impose
excessive force on them.
Precautions for Safe Use
Disposal
Dispose of this product as industrial waste.
Precautions for Correct Use
Storage
Do not store Connectors for long periods of time in the following
locations
• Locations subject to dust or high humidity
• Locations subject to ammonia gas or sulfide gas
Do not use the product in atmospheres or environments that exceed
product ratings.
Connections
• The XS3 and XS2 Sensor I/O Connectors cannot be connected to
each other.
Setup
• Do not make any cable bends near the base of the Unit.
• Any bends made must have a minimum radius of 36 mm.
• You cannot mate Connectors that have a different number of
poles.
• When using Sensors with Connectors or Limit Switches, use the
Sensor I/O Connectors specified in the catalog.
Connector Connection and Disconnection
• Before connecting or disconnecting Connectors, make sure that no
power is being supplied to the Connectors.
• When connecting or disconnecting Connectors, be sure to hold the
Connectors by hand. Do not disconnect the Connectors by pulling
the cable.
• Do not touch the mating surface of the connectors with wet hands.
If there is any water on the Connector or near the Connector, be
sure to wipe off the water before connecting or disconnecting the
Connector, otherwise the Connector may short-circuit internally or
not ensure good insulation.
• Make sure that mating section of any Connector is free of metal
dust or power.
• Do not use tools of any sort to mate the Connectors. Always use
your hands. Pliers or other tools may damage the Connectors. Be
sure to tighten each thread bracket by hand within a torque of 0.2
N·m. If the thread bracket is not tightened securely, the Connector
may not maintain its proper degree of protection or the thread
bracket may fall off due to vibration.
• When you tighten or loosen a thread bracket, hold onto only the
thread bracket.
If you hold onto the cover or cable, excessive rotational force will
be applied to the Connector and may damage it.
106
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
is a registered trademark of OMRON Corporation.
●
●
●
Company names and product names in this document are the trademarks or registered trademarks of their respective companies.
The product photographs and figures that are used in this catalog may vary somewhat from the actual products.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Kyoto, JAPAN
Industrial Automation Company
Authorized Distributor:
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
© OMRON Corporation 2018-2019 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
CSM_1_5_0819
Cat. No. D121-E1-03
0819(1218)