E2E-X8B218-R2M [OMRON]

Inductive Sensor,;
E2E-X8B218-R2M
型号: E2E-X8B218-R2M
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Inductive Sensor,

传感器 换能器
文件: 总108页 (文件大小:32461K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
N
E
W
Proximity Sensors  
DC 3-Wire Models  
E2E NEXT Series  
Exceptional  
sensing  
range*  
9mm  
[Quadruple distance model of M12 sized]  
Enables easier and  
standardized design  
* Based on December 2018 OMRON investigation.  
Proximity Sensors E2E NEXT Series  
2
Enables easier and standardi  
previously not possible  
PREMIUM Model  
Easy design  
Standardized design  
Exceptional  
sensing range  
The PREMIUM Model, which has a longer detection range compared to  
previous models, allows for more spacious designs with less risk of  
contact. It also enables you to standardize your designs by letting you  
adopt a single one-size model instead of multiple models of different  
sizes.  
*1  
[
]
M12  
*2  
9
mm  
Quadruple distance model  
9 mm [M12]  
*1. Based on December 2018 OMRON investigation.  
Triple distance model  
*2. Quadruple distance models of M12 sized  
P.4-7  
6 mm [M12]  
BASIC Model  
Double distance model  
In addition to our HIGH SPEC Models, we also offer  
mid/short-distance BASIC Models, to meet various facility  
design requirement specifications.  
4 mm [M12]  
Single distance model  
2 mm [M12]  
3
zed designs  
New standards for usability  
Early error detection  
all new E2E Sensors can be monitored  
location,  
P.8  
with IO-Link  
1
Quick recovery  
replaceable  
second  
P.10  
P.10  
(adaptor)  
with e-jig  
10  
view  
degree  
with high visibility LED indicator  
360  
Less unexpected facility stoppages  
Strong resistance to  
cutting oil  
P.12  
*3  
oil resistance  
2-year  
*3. Pre-wired models and pre-wired connector models.  
PREMIUM Model  
Proximity Sensors E2E NEXT Series  
4
Equipped with exceptional sensing range*  
to enable collision-free  
sensor installation  
Easy design  
Enables designs with more distance between the sensor and the sensing object, thereby reducing unexpected  
facility stoppages due to collision and false detection, which occurred with previous proximity sensors.  
Previous models  
[Quadruple distance  
mo
d
els of
M1
2 s
ized]  
Exceptional  
E2E NEXT  
sensing range*  
9mm  
* Based on December 2018 OMRON investigation
Stable detection without collision  
5
Allows for more spacious design with  
less risk of contact  
With previous models, to avoid false detections, you were forced to adopt sensor  
installation designs that risked contact. The E2E NEXT PREMIUM Proximity Sensor can  
detect accurately from a greater distance, which means you can adopt designs with  
more space and less risk of contact.  
Approximately double the sensing distance of previous models  
Sensing distance comparisons (Quadruple distance models)  
Shielded  
Previous  
2 mm  
models  
M8  
E2E NEXT  
4 mm  
Exceptional sensing range*  
Previous  
models  
4 mm  
* Based on December 2018 OMRON investigation.  
E2E NEXT  
M12  
M18  
9 mm  
8 mm  
Previous models  
E2E NEXT  
14 mm  
15 mm  
Previous models  
E2E NEXT  
M30  
23 mm  
Longest in the series  
50 mm  
Unshielded  
Previous models  
E2E NEXT  
30 mm  
M30  
Less false detection even when a stationary gets away from the sensor due to  
equipment vibration  
Previous models  
E2E NEXT  
The equipment vibration widens the  
Long-distance detection enhances the degree  
distance between a stationary and a sensor  
to cause false detection and facility stoppages.  
of the detection margin.  
even when a stationary gets away.  
Stable detection  
Stable  
detection  
False  
detection  
4 mm  
9 mm  
Spindle presence detection  
* Quadruple distance models of M12 sized  
PROX3 hybrid circuitry with Thermal Distance Control 2 eliminates ambient temperature influence to enable extended sensing ranges.  
Sensing distance fluctuation due to ambient temperature  
Proximity sensors with longer sensing distance require increased sensitivity. However, with the increased  
sensitivity, temperature changes will have bigger influence in sensing distance, and differences between  
individual sensors will be bigger. E2E NEXT Proximity Sensors (3-wire models) solve these issues by newly  
implementing Thermal Distance Control 2, a technology to enable extended sensing ranges. It enables  
in-line measurements of each sensor’s temperature characteristics, using multiple temperature points, in  
IoT-enabled production processes. The optimal correction values are then calculated based on our unique  
algorithm. The values are written into the  
Before correction  
Sensing object  
analog digital hybrid IC (PROX3) for shipping  
After correction  
Before correction  
to minimize differences between sensors  
and the influence of temperature changes  
that may occur in the customer’s environ-  
ments.  
Corrected with high precision  
using measurement data from  
multiple temperature points  
After correction  
Sensing object  
-25  
+25  
+70  
Patent Pending  
Thermal Distance Control 2 technology reduces the extent of error  
Ambient temperature  
Proximity Sensors E2E NEXT Series  
PREMIUM Model  
6
*1  
Exceptional sensing range  
allows you to standardize your  
Standardized  
design  
design with a single one-size model  
Ensures equivalent sensing distance while being one size smaller than previous models. Equipment and facilities formerly designed to use  
sensors of multiple sizes can now be designed to use sensors that are all the same size, allowing you to standardize your designs.  
Case where either M12 or M18 is used depending on sensing distance  
Previous models  
Two different types of hole designs were required for the sensing distance of 4 mm and 8 mm.  
Required sensing distance  
8 mm  
Required sensing distance  
4 mm  
M18  
M12  
One size  
covers both  
Sensing distance  
2
*
9 mm  
E2E NEXT  
The sensing distance of M12 is 9 mm,  
which means M12 can cover objects  
previously covered by M18. Hole designs  
can be standardized to fit M12 only.  
M12  
*1. Based on December 2018 OMRON investigation.  
*2. Quadruple distance models  
Four types of M12 size sensors are available to meet the need for variable sensing distances for different installation sites.  
Quadruple distance model  
Triple distance model  
Double distance model  
Single distance model  
9 mm  
6 mm  
4 mm  
2 mm  
7
Easy to install, even where space is limited  
E2E NEXT PREMIUM Model Proximity Sensors ensure equivalent sensing distance while being one size smaller  
than previous models, allowing you to install them in spaces where conventional sensors were too big to fit.  
Proximity sensors could not be  
Previous  
models  
installed due to limited space.  
M18  
They can be installed due to  
E2E NEXT  
limited space.  
One size smaller to allow you to  
install proximity sensors where  
space is limited.  
M12  
Note: When installing proximity sensors, make sure to factor the influence of surrounding metal into your designs.  
(Refer to Influence of Surrounding Metal upon Design on page 62 and page 80 for details.)  
One size smaller than previous models  
Size comparisons between models with equivalent sensing distance (“E2E NEXTrefers to quadruple distance models)  
M12  
M8  
M18  
M12  
M30  
M18  
Previous models  
E2E NEXT  
Previous models  
Sensing distance  
8 mm  
E2E NEXT  
Sensing distance  
9 mm  
Previous models  
Sensing distance  
15 mm  
E2E NEXT  
Sensing distance  
14 mm  
Sensing distance Sensing distance  
4 mm  
4 mm  
Unifying the model types to reduce the number of parts kept in inventory.  
Two models (M12 and M18)  
stocked  
The extended range of the new sensors  
allows you to reduce the sensor size from  
M18 down to M12.  
Previous  
models  
E2E NEXT  
M18  
M12  
Sensing distance  
8 mm  
Sensing distance  
M12  
9 mm  
Sensing distance  
4 mm  
Proximity Sensors E2E NEXT Series  
PREMIUM Model  
BASIC Model  
8
New standards for usability  
Early error detection  
Enables facility designs that allow for  
early discovery of the site and  
substance of failure  
Less time required from failure to recovery  
(MTTR: Mean Time To Recovery).  
Excessive  
proximity  
Detects sensor failures  
When NO cable is disconnected  
through two output types,  
Normal operation Failure occurred  
NO and NC  
Enables failure discovery by wiring two  
+V  
NC  
outputs, NO and NC.  
0V  
NO  
9
* Screen is a  
conceptual  
illustration.  
Enables real-time identification of the site and substance of  
sensor failure from a single location  
Sensor No.12 is too  
close to the sensing  
object.  
By using the IO-Link Master to connect proximity sensors to your  
controller, you can use your monitor (HMI) for early discovery of the  
site and substance of proximity sensor failures.  
HMI  
Controller  
IO-Link Master  
Enables predictive maintenance through condition monitoring  
Connecting sensors with controllers using IO-Link Master enables to  
send information necessary for stable operation to host devices. This  
enables condition monitoring and failure detection of sensors, which  
in turn contribute to predictive maintenance of equipment and  
facilities. You can also increase the productivity of your facility by  
accumulating information in databases and feeding analysis results  
back to equipment on the site.  
Cloud  
Factory  
Manufacturing site  
Setup: Integrated software environment  
(Sysmac Studio)  
Database  
Notify sensor status  
Configured and monitored on a one-tool, one-connection basis  
Import information on sensors inside equipment  
Controller  
Feed sensor status analysis  
results back to the site  
Detection margin and present value  
data such as temperature inside the sensor  
IO-Link Master  
Predictive  
maintenance  
IO-Link Master  
IO-Link Sensor  
IO-Link Sensor  
Proximity Sensors E2E NEXT Series  
PREMIUM Model  
BASIC Model  
10  
* Applies only to the description of the high-brightness LED indicator.  
New standards for usability  
Quick recovery  
Enables facility designs that allow for  
quick recovery in case of failure  
Less time required from failure to recovery  
(MTTR: Mean Time To Recovery).  
All around visible high-brightness  
LED indicator  
Adopts high-brightness LED that is more luminous and  
visible than those in previous models. The indicator is visible  
from all angles, reducing the time required for operation  
checks after sensor replacement.  
Visible even in areas deep inside the equipment,  
allowing for quicker replacement  
11  
Replacements in as little as 10 seconds* using e-jig  
Using e-jig eliminates the need for adjustment so that anyone can install in the same position.  
A lot of time required to adjust to the optimum distance.  
Adjustment position varies depending on the worker’s skill and  
makes detection unstable.  
Previous  
models  
2. Check the detection status with the  
workpiece.  
Repeat steps  
1 to 3 until  
detection is  
stabilized.  
1. Fasten the sensor temporarily.  
4. Finish by fixing the nut.  
3. Loosen the nut and adjust the distance.  
Replacement time reduced significantly to approx.  
*
10 sec.  
E2E NEXT  
Eliminating the need for adjustment allows for installation in the same position by any worker.  
1. Insert the sensor into an e-jig.  
Patent Pending  
The O-ring blocks the ingress of foreign  
O-ring  
matter, including cutting oil, into the e-jig  
and ensures positioning precision (IP67G).  
2. Then just fix the sensor.  
* Time required to adjust the distance when installing a sensor.  
Based on OMRON investigation.  
Easily upgrade existing facilities to enable “10-second* proximity sensor replacements”  
The HIGH SPEC Model’s sensing distance is approximately twice that of previous models. For example, the sensing distance of the quadruple distance model of M12 sized is 9 mm, which is about the same as  
conventional M18 models. Using these sensors together with the e-jig allows you to easily upgrade your existing facilities so that you can replace their sensors in just 10 seconds.*  
1. Dismount the M18 proximity sensor from  
the existing facility.  
2. Mount an M18-sized e-jig.  
3. Insert an E2E NEXT Series M12  
Proximity Sensor into the e-jig.  
M18  
M18  
M12  
8 mm  
9 mm  
Proximity sensor  
M18  
E2E NEXT  
M12  
e-jig  
Proximity Sensors E2E NEXT Series  
PREMIUM Model  
12  
BASIC Model  
New standards for usability  
Less unexpected facility stoppages  
Excellent environmental resistance  
enables robust facility design  
Reduces sudden facility stoppages by reducing the number of failures, even in severe environments.  
Unexpected component failures:  
Approx. 30 % are caused by cutting oil.  
Other causes  
Voltage or  
noise  
Cutting oil  
Dust, dirt, or  
spatter  
Temperature  
Shock or vibration  
Environmental Causes of Component Failures  
(Based on June 2016 OMRON investigation.)  
13  
Cables with enhanced oil resistance shut out cutting oil for 2 years*  
Our new PVC compound protects against damage caused by swelling, deterioration or cracking, preventing oil from seeping into and  
destroying internal circuits. Designed to resist oil ingress for up to two years.  
Two years* of stable operation verified by OMRON’s unique evaluation technology  
Verified 2-year oil resistance,*  
based on IP67G and  
Previous  
models  
E2E NEXT  
Cables damaged by cutting oil  
OMRON’s oil-resistant
co
mponent evaluation standards  
PUR cables get cracks un
der  
environments where  
OMRON’s E2E NEXT Series Proximity Sensors use  
PVC cables with enhanced oil resistance, and have  
been evaluated according to IP67G of JIS C 0920,  
and also OMRON’s own, even stricter evaluation  
standards for oil-resistant components.  
wate
r-soluble cutting oil is used.  
Oil resistance:  
2 years*  
OMRON’s Oil-resistant Component Evaluation Standards  
Oil type  
A1 (water-soluble cutting oil)  
1,000 hours of machining  
55 °C  
Evaluation time  
Evaluation temperature  
Dilution concentration  
Criteria  
IP67G  
Oil type  
Evaluation time  
N3 (water-insoluble cutting oil)  
48 hours  
Undiluted  
Evaluation temperature Room temperature  
Appearance, performance, and  
no label text loss  
Dilution concentration  
Criteria  
Appearance and performance  
(Illustration)  
(Illustration)  
Two years* of stable operation verified for pre-wired connector models as well, using  
similar oil resistance tests  
Delivers 2-year oil resistance* by adopting technologies unique  
to OMRON and PVC cables with enhanced oil resistance.  
Patent Pending  
Smartclick connector cables block the ingress of cutting oil,  
and with the same torque, no matter who connects them.  
Fit with just 1/8 of a  
turn and a single click!  
is a registered trademark of  
OMRON Corporation.  
For machining processes where the amount  
Oil Resistance:  
of splashing cutting oil is large,  
oil-resistant  
4 years  
Proximity Sensors E2ER/E2ERZ  
Cat. No. Y215  
*•Applicable oil types: specified in JIS K 2241:2000  
“2-year oil resistance” refers to median values (=Typical values) of the product designs and the oil-resistance performance evaluation results.  
Products to be shipped will have around 2 years of oil resistance; actual oil resistance will vary depending on the product.  
•The pre-wired connector model has a verified oil resistance of 2 years when mated with XS5 NEXT series round oil-resistant connectors.  
This value has not been verified for connector models(M1/M3/M5).  
IP69K compliant for water resistance and wash resistance  
IEC 60529 compliant. Ensures water resistance during hot pressure washing, where equipment is washed intensively with high-pressure water  
or steam. (8,000 to 10,000 kPa pressure, 80°C hot water, 30 seconds for each angle)  
E2E/E2EQ NEXT Series  
Selection Guide  
E2E/E2EQ NEXT Series  
DC 3-wire  
(PREMIUM Model)  
P15  
Premium model capable of  
long-sensing distance with  
enhanced user-friendliness  
3-wire Models  
Proximity Sensor  
E2E/E2EQ NEXT Series  
DC 3-wire  
(BASIC Model)  
P15  
Basic model with the same  
sensing distance as the  
previous model, but with  
enhanced user-friendliness  
E2E/E2EQ NEXT Series  
DC 2-wire  
P67  
2-wire Models  
Oil-resistant model that minimizes  
failures caused by cutting oils  
(oil- and bending-resistant type  
is also available)  
XS5 NEXT Series *  
2 years of oil resistance  
P87  
M12  
Connector Cable  
XS5 Series  
BASIC Model  
P94  
Previous basic model  
XS3W-M8/XS3F-M8 Series  
P102  
M8  
* Applicable oil types: specified in JIS K 2241:2000  
“2-year oil resistance” refers to median values (=Typical values) of the product designs and the oil-resistance performance evaluation results.  
Products to be shipped will have around 2 years of oil resistance; actual oil resistance will vary depending on the product.  
The Pre-wired Connector Model has a verified oil resistance of 2 years when mated with XS5 NEXT Series round oil-resistant connectors.  
14  
Proximity Sensor  
E2E/E2EQ NEXT Series  
DC 3-Wire  
Enables easier and standardized designs  
previously not possible  
• The world's longest sensing distance*1  
Nearly double the sensing distance of previous  
• With high-brightness LED, the indicator is visible anywhere from 360°.  
• Only 10 Seconds*2 to Replace a Proximity Sensor with the "e-jig"  
(Mounting Sleeve).  
• Cables with enhanced oil resistance enabled 2-year oil resistance*3.  
4
• IP69K compliant for water resistance and wash resistance  
• Comes in a wide variation to make sensor selection easy  
*
• UL certification (UL60947-5-2)*5 and CSA certification (CSA  
For the most recent information on models that have been  
certified for safety standards, refer to your OMRON website.  
C22.2 UL60947-5-2-14)  
*1. Based on December 2018 OMRON investigation.  
*2. Time required to adjust the distance when installing a Sensor. Based on OMRON investigation.  
*3. Refer to Ratings and Specifications for details. However, E2E Connector Models and E2EQ series is excluded.  
*4. E2EQ series is excluded.  
*5. M8 (4-pin) Connector Models are not UL certified.  
Be sure to read Safety Precautions on page 61.  
Features  
PREMIUM Model  
Quadruple distance model  
Easy design  
Standardized design  
9mm [M12]  
Exceptional  
sensing  
[M12]  
*6  
range  
9
mm*7  
The PREMIUM Model, which has a longer detection  
range compared to previous models, allows for  
more spacious designs with less risk of contact. It  
also enables you to standardize your designs by  
letting you adopt a single one-size model instead of  
multiple models of different sizes.  
Triple distance model  
6mm [M12]  
*6. Based on December 2018 OMRON investigation.  
*7. Quadruple distance models of M12 sized  
New standards for usability  
Early error detection  
Less unexpected  
facility stoppages  
BASIC Model  
all new E2E Sensors  
location,  
Strong resistance to  
cutting oil  
can be monitored  
In addition to our HIGH SPEC Models, we  
also offer mid/short-distance BASIC  
Models, to meet various facility design  
requirement specifications.  
1
*3  
2-year  
with IO-Link  
oil resistance *9  
*9. E2E Connector Models and E2EQ series is  
excluded.  
Quick recovery  
Double distance model  
replaceable  
second  
4mm [M12]  
with e-jig (adaptor)  
*8  
10  
view  
Single distance model  
degree  
with high visibility  
LED indicator  
2mm [M12]  
360°  
*8. Time required to adjust the distance when installing a Sensor. Based on OMRON investigation.  
15  
E2E/E2EQ NEXT Series  
E2E/E2EQ NEXT Series Model Number Legend  
DC 3-wire  
(1)  
(2) (3) (4) (5) (6) (7) (8) (9) (10)  
(11)  
-
-
-
-
E2E  
X
No.  
Type  
Code  
Blank  
Q
Meaning  
Without spatter-resistant coating  
(1)  
(2)  
(3)  
Case  
With spatter-resistant coating  
Sensing distance (Unit: mm)  
(R: Indication of decimal point)  
Sensing distance  
Shielding  
Number  
Blank  
M
Shielded  
Unshielded  
B
PNP open collector  
NPN open collector  
Normally open (NO)  
Normally closed (NC)  
Normally open, Normally closed (NO+NC)  
Non IO-Link compliant  
COM2 (38.4 kbps)  
COM3 (230.4 kbps)  
Standard  
(4)  
(5)  
Output configuration  
Operation mode  
C
1
2
3
Blank  
D
(6)  
(7)  
IO-Link baud rate  
Body size  
T
Blank  
L
Long Body  
8
M8  
12  
M12  
(8)  
Size  
18  
M18  
30  
M30  
Blank  
M1  
M3  
M5  
M1TJ  
Pre-wired Models  
M12 Connector Models  
M8 (4-pin) Connector Models  
M8 (3-pin) Connector Models  
M12 Pre-wired Smartclick Connector Models  
(9)  
Connection method  
M12 Pre-wired Smartclick Connector Models  
Robot (bending-resistant) cable  
M1TJR  
Blank  
R
Standard PVC cable  
Robot (bending-resistant) cable  
Cable length  
(10)  
(11)  
Cable specifications *  
Cable length  
Number M  
* (10) is only shown in the model number of Pre-wired Models.  
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.  
Models are not available for all combinations of code numbers.  
16  
E2E/E2EQ NEXT Series  
Ordering Information  
PREMIUM Model  
E2E NEXT Series (Quadruple distance model)  
DC 3-wire [Refer to Dimensions on page 64.]  
Shielded *1  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
E2E-X4B1T8 2M  
IO-Link (COM2) *5  
E2E-X4B1D8 2M  
--- *5  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
E2E-X4C18 2M  
38 mm  
*3  
-
E2E-X4B28 2M  
E2E-X4C28 2M  
Pre-wired (2 m) *2  
E2E-X4B1TL8 2M  
E2E-X4B1DL8 2M  
E2E-X4C1L8 2M  
48 mm  
-
E2E-X4B2L8 2M  
E2E-X4C2L8 2M  
E2E-X4B1T8-M1TJ 0.3M  
E2E-X4B1D8-M1TJ 0.3M  
E2E-X4B28-M1TJ 0.3M  
E2E-X4B1DL8-M1TJ 0.3M  
E2E-X4B2L8-M1TJ 0.3M  
E2E-X4B1D8-M1  
E2E-X4C18-M1TJ 0.3M  
E2E-X4C28-M1TJ 0.3M  
E2E-X4C1L8-M1TJ 0.3M  
E2E-X4C2L8-M1TJ 0.3M  
E2E-X4C18-M1  
38 mm  
*4  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
-
E2E-X4B1TL8-M1TJ 0.3M  
48 mm  
43 mm  
53 mm  
39 mm  
49 mm  
39 mm  
49 mm  
-
E2E-X4B1T8-M1  
-
E2E-X4B28-M1  
E2E-X4C28-M1  
M8  
(4 mm)  
M12 Connector  
E2E-X4B1TL8-M1  
E2E-X4B1DL8-M1  
E2E-X4B2L8-M1  
E2E-X4C1L8-M1  
-
E2E-X4C2L8-M1  
E2E-X4B1T8-M3  
E2E-X4B1D8-M3  
E2E-X4C18-M3  
-
E2E-X4B28-M3  
E2E-X4C28-M3  
M8 Connector  
(4-pin)  
E2E-X4B1TL8-M3  
E2E-X4B1DL8-M3  
E2E-X4B2L8-M3  
E2E-X4C1L8-M3  
-
E2E-X4C2L8-M3  
E2E-X4B1T8-M5  
E2E-X4B1D8-M5  
E2E-X4C18-M5  
-
E2E-X4B28-M5  
E2E-X4C28-M5  
M8 Connector  
(3-pin)  
E2E-X4B1TL8-M5  
E2E-X4B1DL8-M5  
E2E-X4B2L8-M5  
E2E-X4C1L8-M5  
-
E2E-X4C2L8-M5  
E2E-X9B1T12 2M  
E2E-X9B1D12 2M  
E2E-X9C112 2M  
47 mm  
*3  
-
E2E-X9B212 2M  
E2E-X9C212 2M  
Pre-wired (2 m) *2  
E2E-X9B1TL12 2M  
E2E-X9B1DL12 2M  
E2E-X9B2L12 2M  
E2E-X9C1L12 2M  
E2E-X9C2L12 2M  
E2E-X9C112-M1TJ 0.3M  
E2E-X9C212-M1TJ 0.3M  
E2E-X9C1L12-M1TJ 0.3M  
E2E-X9C2L12-M1TJ 0.3M  
E2E-X9C112-M1  
69 mm  
-
E2E-X9B1T12-M1TJ 0.3M  
E2E-X9B1D12-M1TJ 0.3M  
E2E-X9B212-M1TJ 0.3M  
E2E-X9B1DL12-M1TJ 0.3M  
E2E-X9B2L12-M1TJ 0.3M  
E2E-X9B1D12-M1  
47 mm  
*4  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
-
M12  
(9 mm)  
E2E-X9B1TL12-M1TJ 0.3M  
69 mm  
48 mm  
70 mm  
-
E2E-X9B1T12-M1  
-
E2E-X9B212-M1  
E2E-X9C212-M1  
M12 Connector  
E2E-X9B1TL12-M1  
E2E-X9B1DL12-M1  
E2E-X9B2L12-M1  
E2E-X9C1L12-M1  
E2E-X9C2L12-M1  
E2E-X14C118 2M  
E2E-X14C218 2M  
E2E-X14C1L18 2M  
E2E-X14C2L18 2M  
E2E-X14C118-M1TJ 0.3M  
E2E-X14C218-M1TJ 0.3M  
E2E-X14C1L18-M1TJ 0.3M  
E2E-X14C2L18-M1TJ 0.3M  
E2E-X14C118-M1  
E2E-X14C218-M1  
E2E-X14C1L18-M1  
E2E-X14C2L18-M1  
-
E2E-X14B1T18 2M  
E2E-X14B1D18 2M  
E2E-X14B218 2M  
55 mm  
*3  
-
Pre-wired (2 m) *2  
E2E-X14B1TL18 2M  
E2E-X14B1DL18 2M  
E2E-X14B2L18 2M  
E2E-X14B1D18-M1TJ 0.3M  
E2E-X14B218-M1TJ 0.3M  
E2E-X14B1DL18-M1TJ 0.3M  
E2E-X14B2L18-M1TJ 0.3M  
E2E-X14B1D18-M1  
E2E-X14B218-M1  
77 mm  
-
E2E-X14B1T18-M1TJ 0.3M  
-
55 mm  
*4  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
M18  
(14 mm)  
E2E-X14B1TL18-M1TJ 0.3M  
77 mm  
53 mm  
75 mm  
-
E2E-X14B1T18-M1  
-
M12 Connector  
E2E-X14B1TL18-M1  
-
E2E-X14B1DL18-M1  
E2E-X14B2L18-M1  
17  
E2E/E2EQ NEXT Series  
PREMIUM Model  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *5  
E2E-X23B1D30 2M  
--- *5  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
E2E-X23B1T30 2M  
E2E-X23C130 2M  
60 mm  
*4  
-
E2E-X23B230 2M  
E2E-X23C230 2M  
Pre-wired (2 m) *2  
E2E-X23B1TL30 2M  
E2E-X23B1DL30 2M  
E2E-X23B2L30 2M  
E2E-X23C1L30 2M  
E2E-X23C2L30 2M  
E2E-X23C130-M1TJ 0.3M  
E2E-X23C230-M1TJ 0.3M  
E2E-X23C1L30-M1TJ 0.3M  
E2E-X23C2L30-M1TJ 0.3M  
E2E-X23C130-M1  
E2E-X23C230-M1  
E2E-X23C1L30-M1  
E2E-X23C2L30-M1  
82 mm  
-
E2E-X23B1T30-M1TJ 0.3M  
-
E2E-X23B1D30-M1TJ 0.3M  
E2E-X23B230-M1TJ 0.3M  
E2E-X23B1DL30-M1TJ 0.3M  
E2E-X23B2L30-M1TJ 0.3M  
E2E-X23B1D30-M1  
60 mm  
*4  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
M30  
(23 mm)  
E2E-X23B1TL30-M1TJ 0.3M  
82 mm  
58 mm  
80 mm  
-
E2E-X23B1T30-M1  
-
E2E-X23B230-M1  
M12 Connector  
E2E-X23B1TL30-M1  
-
E2E-X23B1DL30-M1  
E2E-X23B2L30-M1  
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 62.  
*2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2E-X9B1D12 5M)  
*3. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X9B1D12-R 2M/  
E2E-X9B1D12-R 5M)  
*4. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with "R" in the model number. (Example: E2E-  
X9B1D12-M1TJR 0.3M)  
*5. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
18  
E2E/E2EQ NEXT Series  
PREMIUM Model  
E2E NEXT Series (Quadruple distance model)  
DC 3-wire [Refer to Dimensions on page 64.]  
Unshielded  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X8MB1D8 2M  
--- *4  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
NO  
NC  
E2E-X8MB1T8 2M  
E2E-X8MC18 2M  
38 mm  
*2  
-
E2E-X8MB28 2M  
E2E-X8MC28 2M  
Pre-wired (2 m) *1  
E2E-X8MB1TL8 2M  
E2E-X8MB1DL8 2M  
E2E-X8MB2L8 2M  
E2E-X8MC1L8 2M  
48 mm  
-
E2E-X8MC2L8 2M  
E2E-X8MB1T8-M1TJ 0.3M  
E2E-X8MB1D8-M1TJ 0.3M  
E2E-X8MB28-M1TJ 0.3M  
E2E-X8MB1DL8-M1TJ 0.3M  
E2E-X8MB2L8-M1TJ 0.3M  
E2E-X8MB1D8-M1  
E2E-X8MC18-M1TJ 0.3M  
E2E-X8MC28-M1TJ 0.3M  
E2E-X8MC1L8-M1TJ 0.3M  
E2E-X8MC2L8-M1TJ 0.3M  
E2E-X8MC18-M1  
38 mm  
*3  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
-
E2E-X8MB1TL8-M1TJ 0.3M  
48 mm  
43 mm  
53 mm  
39 mm  
49 mm  
39 mm  
49 mm  
-
E2E-X8MB1T8-M1  
-
E2E-X8MB28-M1  
E2E-X8MC28-M1  
M8  
(8 mm)  
M12 Connector  
E2E-X8MB1TL8-M1  
E2E-X8MB1DL8-M1  
E2E-X8MB2L8-M1  
E2E-X8MC1L8-M1  
-
E2E-X8MC2L8-M1  
E2E-X8MB1T8-M3  
E2E-X8MB1D8-M3  
E2E-X8MC18-M3  
-
E2E-X8MB28-M3  
E2E-X8MC28-M3  
M8 Connector  
(4-pin)  
E2E-X8MB1TL8-M3  
E2E-X8MB1DL8-M3  
E2E-X8MB2L8-M3  
E2E-X8MC1L8-M3  
-
E2E-X8MC2L8-M3  
E2E-X8MB1T8-M5  
E2E-X8MB1D8-M5  
E2E-X8MC18-M5  
-
E2E-X8MB28-M5  
E2E-X8MC28-M5  
M8 Connector  
(3-pin)  
E2E-X8MB1TL8-M5  
E2E-X8MB1DL8-M5  
E2E-X8MB2L8-M5  
E2E-X8MC1L8-M5  
-
E2E-X8MC2L8-M5  
E2E-X16MB1T12 2M  
E2E-X16MB1D12 2M  
E2E-X16MB212 2M  
E2E-X16MC112 2M  
E2E-X16MC212 2M  
E2E-X16MC1L12 2M  
E2E-X16MC2L12 2M  
E2E-X16MC112-M1TJ 0.3M  
E2E-X16MC212-M1TJ 0.3M  
E2E-X16MC1L12-M1TJ 0.3M  
E2E-X16MC2L12-M1TJ 0.3M  
E2E-X16MC112-M1  
E2E-X16MC212-M1  
E2E-X16MC1L12-M1  
E2E-X16MC2L12-M1  
E2E-X30MC1L18 2M  
E2E-X30MC2L18 2M  
47 mm  
*2  
-
Pre-wired (2 m) *1  
E2E-X16MB1TL12 2M  
-
E2E-X16MB1DL12 2M  
E2E-X16MB2L12 2M  
E2E-X16MB1D12-M1TJ 0.3M  
E2E-X16MB212-M1TJ 0.3M  
E2E-X16MB1DL12-M1TJ 0.3M  
E2E-X16MB2L12-M1TJ 0.3M  
E2E-X16MB1D12-M1  
E2E-X16MB212-M1  
E2E-X16MB1DL12-M1  
E2E-X16MB2L12-M1  
E2E-X30MB1DL18 2M  
E2E-X30MB2L18 2M  
69 mm  
E2E-X16MB1T12-M1TJ 0.3M  
47 mm  
*3  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
-
M12  
(16 mm)  
E2E-X16MB1TL12-M1TJ 0.3M  
69 mm  
48 mm  
70 mm  
-
E2E-X16MB1T12-M1  
-
M12 Connector  
E2E-X16MB1TL12-M1  
-
E2E-X30MB1TL18 2M  
-
77 mm  
*2  
Pre-wired (2 m) *1  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO  
NC  
E2E-X30MB1TL18-M1TJ 0.3M  
-
E2E-X30MB1DL18-M1TJ 0.3M  
E2E-X30MB2L18-M1TJ 0.3M  
E2E-X30MC1L18-M1TJ 0.3M  
E2E-X30MC2L18-M1TJ 0.3M  
M18  
(30 mm)  
77 mm  
*3  
NO  
NC  
NO  
NC  
E2E-X30MB1TL18-M1  
E2E-X30MB1DL18-M1  
E2E-X30MB2L18-M1  
E2E-X50MB1DL30 2M  
E2E-X50MB2L30 2M  
E2E-X30MC1L18-M1  
E2E-X30MC2L18-M1  
E2E-X50MC1L30 2M  
E2E-X50MC2L30 2M  
M12 Connector  
75 mm  
-
E2E-X50MB1TL30 2M  
-
97 mm  
*2  
Pre-wired (2 m) *1  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO  
NC  
E2E-X50MB1TL30-M1TJ 0.3M  
-
E2E-X50MB1DL30-M1TJ 0.3M  
E2E-X50MB2L30-M1TJ 0.3M  
E2E-X50MC1L30-M1TJ 0.3M  
E2E-X50MC2L30-M1TJ 0.3M  
M30  
(50 mm)  
97 mm  
*3  
NO  
NC  
E2E-X50MB1TL30-M1  
-
E2E-X50MB1DL30-M1  
E2E-X50MB2L30-M1  
E2E-X50MC1L30-M1  
E2E-X50MC2L30-M1  
M12 Connector  
95 mm  
*1. Models with 5-m cable length are also available (Example: E2E-X16MB1D12 5M)  
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X16MB1D12-R  
2M/E2E-X16MB1D12-R 5M)  
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-  
X16MB1D12-M1TJR 0.3M)  
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
19  
E2E/E2EQ NEXT Series  
PREMIUM Model  
E2E NEXT Series (Triple distance model)  
DC 3-wire [Refer to Dimensions on page 64.]  
Shielded *1  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
E2E-X3B1T8 2M  
IO-Link (COM2) *5  
E2E-X3B1D8 2M  
--- *5  
NO  
NC  
E2E-X3C18 2M  
38 mm  
*3  
-
E2E-X3B28 2M  
E2E-X3C28 2M  
Pre-wired (2 m) *2  
NO  
E2E-X3B1TL8 2M  
E2E-X3B1DL8 2M  
E2E-X3B2L8 2M  
E2E-X3C1L8 2M  
48 mm  
NC  
-
E2E-X3C2L8 2M  
NO  
E2E-X3B1T8-M1TJ 0.3M  
E2E-X3B1D8-M1TJ 0.3M  
E2E-X3B28-M1TJ 0.3M  
E2E-X3B1DL8-M1TJ 0.3M  
E2E-X3B2L8-M1TJ 0.3M  
E2E-X3B1D8-M1  
E2E-X3C18-M1TJ 0.3M  
E2E-X3C28-M1TJ 0.3M  
E2E-X3C1L8-M1TJ 0.3M  
E2E-X3C2L8-M1TJ 0.3M  
E2E-X3C18-M1  
38 mm  
*4  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NC  
-
NO  
E2E-X3B1TL8-M1TJ 0.3M  
48 mm  
43 mm  
53 mm  
39 mm  
49 mm  
39 mm  
49 mm  
NC  
-
NO  
E2E-X3B1T8-M1  
NC  
-
E2E-X3B28-M1  
E2E-X3C28-M1  
M8  
(3 mm)  
M12 Connector  
NO  
E2E-X3B1TL8-M1  
E2E-X3B1DL8-M1  
E2E-X3B2L8-M1  
E2E-X3C1L8-M1  
E2E-X3C2L8-M1  
E2E-X3C18-M3  
NC  
-
NO  
E2E-X3B1T8-M3  
E2E-X3B1D8-M3  
NC  
-
E2E-X3B28-M3  
E2E-X3C28-M3  
M8 Connector  
(4-pin)  
NO  
E2E-X3B1TL8-M3  
E2E-X3B1DL8-M3  
E2E-X3B2L8-M3  
E2E-X3C1L8-M3  
E2E-X3C2L8-M3  
E2E-X3C18-M5  
NC  
-
NO  
E2E-X3B1T8-M5  
E2E-X3B1D8-M5  
NC  
-
E2E-X3B28-M5  
E2E-X3C28-M5  
M8 Connector  
(3-pin)  
NO  
E2E-X3B1TL8-M5  
E2E-X3B1DL8-M5  
E2E-X3B2L8-M5  
E2E-X3C1L8-M5  
E2E-X3C2L8-M5  
E2E-X6C112 2M  
NC  
-
NO  
E2E-X6B1T12 2M  
E2E-X6B1D12 2M  
E2E-X6B212 2M  
47 mm  
*3  
NC  
-
E2E-X6C212 2M  
NO+NC  
NO  
-
E2E-X6B3D12 2M  
E2E-X6B1DL12 2M  
E2E-X6B2L12 2M  
E2E-X6C312 2M  
Pre-wired (2 m) *2  
E2E-X6B1TL12 2M  
E2E-X6C1L12 2M  
E2E-X6C2L12 2M  
E2E-X6C3L12 2M  
E2E-X6C112-M1TJ 0.3M  
E2E-X6C212-M1TJ 0.3M  
E2E-X6C312-M1TJ 0.3M  
E2E-X6C1L12-M1TJ 0.3M  
E2E-X6C2L12-M1TJ 0.3M  
E2E-X6C3L12-M1TJ 0.3M  
E2E-X6C112-M1  
69 mm  
NC  
-
NO+NC  
NO  
-
E2E-X6B3DL12 2M  
E2E-X6B1D12-M1TJ 0.3M  
E2E-X6B212-M1TJ 0.3M  
E2E-X6B3D12-M1TJ 0.3M  
E2E-X6B1DL12-M1TJ 0.3M  
E2E-X6B2L12-M1TJ 0.3M  
E2E-X6B3DL12-M1TJ 0.3M  
E2E-X6B1D12-M1  
E2E-X6B212-M1  
E2E-X6B1T12-M1TJ 0.3M  
47 mm  
*4  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M12  
(6 mm)  
E2E-X6B1TL12-M1TJ 0.3M  
69 mm  
48 mm  
70 mm  
NC  
-
NO+NC  
NO  
-
E2E-X6B1T12-M1  
NC  
-
E2E-X6C212-M1  
NO+NC  
NO  
-
E2E-X6B3D12-M1  
E2E-X6B1DL12-M1  
E2E-X6B2L12-M1  
E2E-X6B3DL12-M1  
E2E-X6C312-M1  
M12 Connector  
E2E-X6B1TL12-M1  
E2E-X6C1L12-M1  
E2E-X6C2L12-M1  
E2E-X6C3L12-M1  
NC  
-
-
NO+NC  
20  
E2E/E2EQ NEXT Series  
PREMIUM Model  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *5  
E2E-X12B1D18 2M  
--- *5  
NO  
NC  
E2E-X12B1T18 2M  
E2E-X12C118 2M  
55 mm  
*3  
-
E2E-X12B218 2M  
E2E-X12C218 2M  
NO+NC  
NO  
-
E2E-X12B3D18 2M  
E2E-X12C318 2M  
Pre-wired (2 m) *2  
E2E-X12B1TL18 2M  
E2E-X12B1DL18 2M  
E2E-X12B2L18 2M  
E2E-X12C1L18 2M  
77 mm  
NC  
-
E2E-X12C2L18 2M  
NO+NC  
NO  
-
E2E-X12B3DL18 2M  
E2E-X12B1D18-M1TJ 0.3M  
E2E-X12B218-M1TJ 0.3M  
E2E-X12B3D18-M1TJ 0.3M  
E2E-X12B1DL18-M1TJ 0.3M  
E2E-X12B2L18-M1TJ 0.3M  
E2E-X12B3DL18-M1TJ 0.3M  
E2E-X12B1D18-M1  
E2E-X12C3L18 2M  
E2E-X12B1T18-M1TJ 0.3M  
E2E-X12C118-M1TJ 0.3M  
E2E-X12C218-M1TJ 0.3M  
E2E-X12C318-M1TJ 0.3M  
E2E-X12C1L18-M1TJ 0.3M  
E2E-X12C2L18-M1TJ 0.3M  
E2E-X12C3L18-M1TJ 0.3M  
E2E-X12C118-M1  
55 mm  
*4  
NC  
-
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
M18  
(12 mm)  
E2E-X12B1TL18-M1TJ 0.3M  
77 mm  
53 mm  
75 mm  
NC  
-
NO+NC  
NO  
-
E2E-X12B1T18-M1  
NC  
-
E2E-X12B218-M1  
E2E-X12C218-M1  
NO+NC  
NO  
-
E2E-X12B3D18-M1  
E2E-X12C318-M1  
M12 Connector  
E2E-X12B1TL18-M1  
E2E-X12B1DL18-M1  
E2E-X12B2L18-M1  
E2E-X12C1L18-M1  
E2E-X12C2L18-M1  
E2E-X12C3L18-M1  
E2E-X22C130 2M  
NC  
-
NO+NC  
NO  
-
E2E-X12B3DL18-M1  
E2E-X22B1D30 2M  
E2E-X22B1T30 2M  
60 mm  
*3  
NC  
-
E2E-X22B230 2M  
E2E-X22C230 2M  
NO+NC  
NO  
-
E2E-X22B3D30 2M  
E2E-X22C330 2M  
Pre-wired (2 m) *2  
E2E-X22B1TL30 2M  
E2E-X22B1DL30 2M  
E2E-X22B2L30 2M  
E2E-X22C1L30 2M  
82 mm  
NC  
-
E2E-X22C2L30 2M  
NO+NC  
NO  
-
E2E-X22B3DL30 2M  
E2E-X22B1D30-M1TJ 0.3M  
E2E-X22B230-M1TJ 0.3M  
E2E-X22B3D30-M1TJ 0.3M  
E2E-X22B1DL30-M1TJ 0.3M  
E2E-X22B2L30-M1TJ 0.3M  
E2E-X22B3DL30-M1TJ 0.3M  
E2E-X22B1D30-M1  
E2E-X22C3L30 2M  
E2E-X22B1T30-M1TJ 0.3M  
E2E-X22C130-M1TJ 0.3M  
E2E-X22C230-M1TJ 0.3M  
E2E-X22C330-M1TJ 0.3M  
E2E-X22C1L30-M1TJ 0.3M  
E2E-X22C2L30-M1TJ 0.3M  
E2E-X22C3L30-M1TJ 0.3M  
E2E-X22C130-M1  
60 mm  
*4  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M30  
(22 mm)  
E2E-X22B1TL30-M1TJ 0.3M  
82 mm  
58 mm  
80 mm  
NC  
-
NO+NC  
NO  
-
E2E-X22B1T30-M1  
NC  
-
E2E-X22B230-M1  
E2E-X22C230-M1  
NO+NC  
NO  
-
E2E-X22B3D30-M1  
E2E-X22C330-M1  
M12 Connector  
E2E-X22B1TL30-M1  
E2E-X22B1DL30-M1  
E2E-X22B2L30-M1  
E2E-X22C1L30-M1  
E2E-X22C2L30-M1  
E2E-X22C3L30-M1  
NC  
-
-
NO+NC  
E2E-X22B3DL30-M1  
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 62.  
*2. Models with 5-m cable length are also available (Example: E2E-X6B1D12 5M)  
*3. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X6B1D12-R 2M/  
E2E-X6B1D12-R 5M)  
*4. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-  
X6B1D12-M1TJR 0.3M)  
*5. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
21  
E2E/E2EQ NEXT Series  
PREMIUM Model  
E2E NEXT Series (Triple distance model)  
DC 3-wire [Refer to Dimensions on page 64.]  
Unshielded  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
--- *4  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X6MB1D8 2M  
NO  
E2E-X6MB1T8 2M  
E2E-X6MC18 2M  
38 mm  
*2  
NC  
NO  
-
E2E-X6MB28 2M  
E2E-X6MC28 2M  
Pre-wired (2 m) *1  
E2E-X6MB1TL8 2M  
E2E-X6MB1DL8 2M  
E2E-X6MC1L8 2M  
48 mm  
NC  
-
E2E-X6MB2L8 2M  
E2E-X6MC2L8 2M  
NO  
E2E-X6MB1T8-M1TJ 0.3M  
E2E-X6MB1D8-M1TJ 0.3M  
E2E-X6MB28-M1TJ 0.3M  
E2E-X6MB1DL8-M1TJ 0.3M  
E2E-X6MB2L8-M1TJ 0.3M  
E2E-X6MB1D8-M1  
E2E-X6MC18-M1TJ 0.3M  
E2E-X6MC28-M1TJ 0.3M  
E2E-X6MC1L8-M1TJ 0.3M  
E2E-X6MC2L8-M1TJ 0.3M  
E2E-X6MC18-M1  
38 mm  
*3  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NC  
-
NO  
E2E-X6MB1TL8-M1TJ 0.3M  
48 mm  
43 mm  
53 mm  
39 mm  
49 mm  
39 mm  
49 mm  
NC  
-
NO  
E2E-X6MB1T8-M1  
NC  
-
E2E-X6MB28-M1  
E2E-X6MC28-M1  
M8  
(6 mm)  
M12 Connector  
NO  
E2E-X6MB1TL8-M1  
E2E-X6MB1DL8-M1  
E2E-X6MB2L8-M1  
E2E-X6MC1L8-M1  
NC  
-
E2E-X6MC2L8-M1  
NO  
E2E-X6MB1T8-M3  
E2E-X6MB1D8-M3  
E2E-X6MC18-M3  
NC  
-
E2E-X6MB28-M3  
E2E-X6MC28-M3  
M8 Connector  
(4-pin)  
NO  
E2E-X6MB1TL8-M3  
E2E-X6MB1DL8-M3  
E2E-X6MB2L8-M3  
E2E-X6MC1L8-M3  
NC  
-
E2E-X6MC2L8-M3  
NO  
E2E-X6MB1T8-M5  
E2E-X6MB1D8-M5  
E2E-X6MC18-M5  
NC  
-
E2E-X6MB28-M5  
E2E-X6MC28-M5  
M8 Connector  
(3-pin)  
NO  
E2E-X6MB1TL8-M5  
E2E-X6MB1DL8-M5  
E2E-X6MB2L8-M5  
E2E-X6MC1L8-M5  
NC  
-
E2E-X6MC2L8-M5  
NO  
E2E-X10MB1T12 2M  
E2E-X10MB1D12 2M  
E2E-X10MB212 2M  
E2E-X10MC112 2M  
E2E-X10MC212 2M  
E2E-X10MC312 2M  
E2E-X10MC1L12 2M  
E2E-X10MC2L12 2M  
E2E-X10MC3L12 2M  
E2E-X10MC112-M1TJ 0.3M  
E2E-X10MC212-M1TJ 0.3M  
E2E-X10MC312-M1TJ 0.3M  
E2E-X10MC1L12-M1TJ 0.3M  
E2E-X10MC2L12-M1TJ 0.3M  
E2E-X10MC3L12-M1TJ 0.3M  
E2E-X10MC112-M1  
E2E-X10MC212-M1  
E2E-X10MC312-M1  
E2E-X10MC1L12-M1  
E2E-X10MC2L12-M1  
E2E-X10MC3L12-M1  
E2E-X20MC1L18 2M  
E2E-X20MC2L18 2M  
E2E-X20MC3L18 2M  
E2E-X20MC1L18-M1TJ 0.3M  
47 mm  
*2  
NC  
-
NO+NC  
NO  
-
E2E-X10MB3D12 2M  
E2E-X10MB1DL12 2M  
E2E-X10MB2L12 2M  
E2E-X10MB3DL12 2M  
E2E-X10MB1D12-M1TJ 0.3M  
E2E-X10MB212-M1TJ 0.3M  
E2E-X10MB3D12-M1TJ 0.3M  
E2E-X10MB1DL12-M1TJ 0.3M  
E2E-X10MB2L12-M1TJ 0.3M  
E2E-X10MB3DL12-M1TJ 0.3M  
E2E-X10MB1D12-M1  
E2E-X10MB212-M1  
Pre-wired (2 m) *1  
E2E-X10MB1TL12 2M  
69 mm  
NC  
-
-
NO+NC  
NO  
E2E-X10MB1T12-M1TJ 0.3M  
47 mm  
*3  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M12  
(10 mm)  
E2E-X10MB1TL12-M1TJ 0.3M  
69 mm  
48 mm  
70 mm  
NC  
-
NO+NC  
NO  
-
E2E-X10MB1T12-M1  
NC  
-
NO+NC  
NO  
-
E2E-X10MB3D12-M1  
E2E-X10MB1DL12-M1  
E2E-X10MB2L12-M1  
E2E-X10MB3DL12-M1  
E2E-X20MB1DL18 2M  
E2E-X20MB2L18 2M  
E2E-X20MB3DL18 2M  
E2E-X20MB1DL18-M1TJ  
M12 Connector  
E2E-X10MB1TL12-M1  
NC  
-
NO+NC  
NO  
-
E2E-X20MB1TL18 2M  
77 mm  
*2  
Pre-wired (2 m) *1  
NC  
-
NO+NC  
NO  
-
E2E-X20MB1TL18-M1TJ  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
M18  
(20 mm)  
77 mm  
*3  
NC  
NO+NC  
NO  
-
E2E-X20MB2L18-M1TJ 0.3M  
E2E-X20MB3DL18-M1TJ 0.3M  
E2E-X20MB1DL18-M1  
E2E-X20MC2L18-M1TJ 0.3M  
E2E-X20MC3L18-M1TJ 0.3M  
E2E-X20MC1L18-M1  
-
E2E-X20MB1TL18-M1  
M12 Connector  
75 mm  
NC  
-
-
E2E-X20MB2L18-M1  
E2E-X20MC2L18-M1  
NO+NC  
E2E-X20MB3DL18-M1  
E2E-X20MC3L18-M1  
22  
E2E/E2EQ NEXT Series  
PREMIUM Model  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X40MB1DL30 2M  
E2E-X40MB2L30 2M  
--- *4  
NO  
NC  
E2E-X40MB1TL30 2M  
E2E-X40MC1L30 2M  
E2E-X40MC2L30 2M  
E2E-X40MC3L30 2M  
E2E-X40MC1L30-M1TJ 0.3M  
E2E-X40MC2L30-M1TJ 0.3M  
E2E-X40MC3L30-M1TJ 0.3M  
E2E-X40MC1L30-M1  
E2E-X40MC2L30-M1  
E2E-X40MC3L30-M1  
82 mm  
*2  
Pre-wired (2 m) *1  
-
-
NO+NC  
NO  
E2E-X40MB3DL30 2M  
E2E-X40MB1DL30-M1TJ 0.3M  
E2E-X40MB2L30-M1TJ 0.3M  
E2E-X40MB3DL30-M1TJ 0.3M  
E2E-X40MB1DL30-M1  
E2E-X40MB2L30-M1  
E2E-X40MB1TL30-M1TJ 0.3M  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
M30  
(40 mm)  
82 mm  
*3  
NC  
-
NO+NC  
NO  
-
E2E-X40MB1TL30-M1  
M12 Connector  
80 mm  
NC  
-
-
NO+NC  
E2E-X40MB3DL30-M1  
*1. Models with 5-m cable length are also available (Example: E2E-X10MB1D12 5M)  
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X10MB1D12-R  
2M/E2E-X10MB1D12-R 5M)  
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-  
X10MB1D12-M1TJR 0.3M)  
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
23  
E2E/E2EQ NEXT Series  
PREMIUM Model  
E2EQ NEXT Series (Spatter-resistant Triple distance model)  
DC 3-wire [Refer to Dimensions on page 64.]  
Shielded *1  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
--- *3  
IO-Link (COM3)  
IO-Link (COM2) *3  
E2EQ-X3B1D8 2M  
E2EQ-X3B28 2M  
NO  
NC  
E2EQ-X3B1T8 2M  
-
E2EQ-X3C18 2M  
E2EQ-X3C28 2M  
Pre-wired (2 m) *2 38 mm  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO  
NC  
E2EQ-X3B1T8-M1TJ 0.3M  
-
E2EQ-X3B1D8-M1TJ 0.3M  
E2EQ-X3B28-M1TJ 0.3M  
E2EQ-X3C18-M1TJ 0.3M  
E2EQ-X3C28-M1TJ 0.3M  
M8  
(3 mm)  
38 mm  
NO  
NC  
E2EQ-X3B1T8-M1  
E2EQ-X3B1D8-M1  
E2EQ-X3C18-M1  
M12 Connector  
43 mm  
-
E2EQ-X3B28-M1  
E2EQ-X3C28-M1  
NO  
E2EQ-X6B1T12 2M  
E2EQ-X6B1D12 2M  
E2EQ-X6C112 2M  
Pre-wired (2 m) *2 47 mm  
M12 Pre-wired  
NC  
-
E2EQ-X6B212 2M  
E2EQ-X6C212 2M  
NO+NC  
NO  
-
E2EQ-X6B3D12 2M  
E2EQ-X6C312 2M  
E2EQ-X6B1T12-M1TJ 0.3M  
E2EQ-X6B1D12-M1TJ 0.3M  
E2EQ-X6B212-M1TJ 0.3M  
E2EQ-X6B3D12-M1TJ 0.3M  
E2EQ-X6B1D12-M1  
E2EQ-X6C112-M1TJ 0.3M  
E2EQ-X6C212-M1TJ 0.3M  
E2EQ-X6C312-M1TJ 0.3M  
E2EQ-X6C112-M1  
M12  
(6 mm)  
Smartclick  
47 mm  
NC  
-
Connector (0.3 m)  
NO+NC  
NO  
-
E2EQ-X6B1T12-M1  
M12 Connector  
48 mm  
NC  
-
E2EQ-X6B212-M1  
E2EQ-X6C212-M1  
NO+NC  
NO  
-
E2EQ-X6B3D12-M1  
E2EQ-X6C312-M1  
E2EQ-X12B1T18 2M  
E2EQ-X12B1D18 2M  
E2EQ-X12B218 2M  
E2EQ-X12C118 2M  
Pre-wired (2 m) *2 55 mm  
M12 Pre-wired  
NC  
-
-
E2EQ-X12C218 2M  
NO+NC  
NO  
E2EQ-X12B3D18 2M  
E2EQ-X12B1D18-M1TJ 0.3M  
E2EQ-X12B218-M1TJ 0.3M  
E2EQ-X12B3D18-M1TJ 0.3M  
E2EQ-X12B1D18-M1  
E2EQ-X12B218-M1  
E2EQ-X12C318 2M  
E2EQ-X12B1T18-M1TJ 0.3M  
E2EQ-X12C118-M1TJ 0.3M  
E2EQ-X12C218-M1TJ 0.3M  
E2EQ-X12C318-M1TJ 0.3M  
E2EQ-X12C118-M1  
E2EQ-X12C218-M1  
E2EQ-X12C318-M1  
E2EQ-X22C130 2M  
M18  
(12 mm)  
Smartclick  
55 mm  
NC  
-
Connector (0.3 m)  
NO+NC  
NO  
-
E2EQ-X12B1T18-M1  
M12 Connector  
53 mm  
NC  
-
NO+NC  
NO  
-
E2EQ-X12B3D18-M1  
E2EQ-X22B1D30 2M  
E2EQ-X22B230 2M  
E2EQ-X22B1T30 2M  
Pre-wired (2 m) *2 60 mm  
M12 Pre-wired  
NC  
-
E2EQ-X22C230 2M  
NO+NC  
NO  
-
E2EQ-X22B3D30 2M  
E2EQ-X22B1D30-M1TJ 0.3M  
E2EQ-X22B230-M1TJ 0.3M  
E2EQ-X22B3D30-M1TJ 0.3M  
E2EQ-X22B1D30-M1  
E2EQ-X22B230-M1  
E2EQ-X22C330 2M  
E2EQ-X22B1T30-M1TJ 0.3M  
E2EQ-X22C130-M1TJ 0.3M  
E2EQ-X22C230-M1TJ 0.3M  
E2EQ-X22C330-M1TJ 0.3M  
E2EQ-X22C130-M1  
E2EQ-X22C230-M1  
E2EQ-X22C330-M1  
M30  
(22 mm)  
Smartclick  
60 mm  
NC  
-
Connector (0.3 m)  
NO+NC  
NO  
-
E2EQ-X22B1T30-M1  
M12 Connector  
58 mm  
NC  
-
-
NO+NC  
E2EQ-X22B3D30-M1  
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 62.  
*2. Models with 5-m cable length are also available (Example: E2EQ-X6B1D12 5M)  
*3. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
24  
E2E/E2EQ NEXT Series  
BASIC Model  
E2E NEXT Series (Double distance model)  
DC 3-wire [Refer to Dimensions on page 65.]  
Shielded  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
E2E-X2B1T8 2M  
IO-Link (COM2) *4  
E2E-X2B1D8 2M  
--- *4  
NO  
NC  
E2E-X2C18 2M  
38 mm  
*2  
-
E2E-X2B28 2M  
E2E-X2C28 2M  
Pre-wired (2 m) *1  
NO  
E2E-X2B1TL8 2M  
E2E-X2B1DL8 2M  
E2E-X2B2L8 2M  
E2E-X2C1L8 2M  
48 mm  
NC  
-
E2E-X2C2L8 2M  
NO  
E2E-X2B1T8-M1TJ 0.3M  
E2E-X2B1D8-M1TJ 0.3M  
E2E-X2B28-M1TJ 0.3M  
E2E-X2B1DL8-M1TJ 0.3M  
E2E-X2B2L8-M1TJ 0.3M  
E2E-X2B1D8-M1  
E2E-X2C18-M1TJ 0.3M  
E2E-X2C28-M1TJ 0.3M  
E2E-X2C1L8-M1TJ 0.3M  
E2E-X2C2L8-M1TJ 0.3M  
E2E-X2C18-M1  
38 mm  
*3  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NC  
-
NO  
E2E-X2B1TL8-M1TJ 0.3M  
48 mm  
43 mm  
NC  
-
NO  
E2E-X2B1T8-M1  
NC  
-
E2E-X2B28-M1  
E2E-X2C28-M1  
M8  
(2 mm)  
M12 Connector  
NO  
E2E-X2B1TL8-M1  
E2E-X2B1DL8-M1  
E2E-X2B2L8-M1  
E2E-X2C1L8-M1  
53 mm  
NC  
-
E2E-X2C2L8-M1  
NO+NC  
NO  
-
E2E-X2B3DL8-M1  
E2E-X2B1D8-M3  
E2E-X2C3L8-M1  
E2E-X2B1T8-M3  
E2E-X2C18-M3  
39 mm  
49 mm  
39 mm  
49 mm  
NC  
-
E2E-X2B28-M3  
E2E-X2C28-M3  
M8 Connector  
(4-pin)  
NO  
E2E-X2B1TL8-M3  
E2E-X2B1DL8-M3  
E2E-X2B2L8-M3  
E2E-X2C1L8-M3  
NC  
-
E2E-X2C2L8-M3  
NO  
E2E-X2B1T8-M5  
E2E-X2B1D8-M5  
E2E-X2C18-M5  
NC  
-
E2E-X2B28-M5  
E2E-X2C28-M5  
M8 Connector  
(3-pin)  
NO  
E2E-X2B1TL8-M5  
E2E-X2B1DL8-M5  
E2E-X2B2L8-M5  
E2E-X2C1L8-M5  
NC  
-
E2E-X2C2L8-M5  
NO  
E2E-X4B1T12 2M  
E2E-X4B1D12 2M  
E2E-X4B212 2M  
E2E-X4C112 2M  
47 mm  
*2  
NC  
-
E2E-X4C212 2M  
NO+NC  
NO  
-
E2E-X4B3D12 2M  
E2E-X4B1DL12 2M  
E2E-X4B2L12 2M  
E2E-X4C312 2M  
Pre-wired (2 m) *1  
E2E-X4B1TL12 2M  
E2E-X4C1L12 2M  
E2E-X4C2L12 2M  
E2E-X4C3L12 2M  
E2E-X4C112-M1TJ 0.3M  
E2E-X4C212-M1TJ 0.3M  
E2E-X4C312-M1TJ 0.3M  
E2E-X4C1L12-M1TJ 0.3M  
E2E-X4C2L12-M1TJ 0.3M  
E2E-X4C3L12-M1TJ 0.3M  
E2E-X4C112-M1  
69 mm  
NC  
-
NO+NC  
NO  
-
E2E-X4B3DL12 2M  
E2E-X4B1D12-M1TJ 0.3M  
E2E-X4B212-M1TJ 0.3M  
E2E-X4B3D12-M1TJ 0.3M  
E2E-X4B1DL12-M1TJ 0.3M  
E2E-X4B2L12-M1TJ 0.3M  
E2E-X4B3DL12-M1TJ 0.3M  
E2E-X4B1D12-M1  
E2E-X4B212-M1  
E2E-X4B1T12-M1TJ 0.3M  
47 mm  
*3  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M12  
(4 mm)  
E2E-X4B1TL12-M1TJ 0.3M  
69 mm  
48 mm  
70 mm  
NC  
-
NO+NC  
NO  
-
E2E-X4B1T12-M1  
NC  
-
E2E-X4C212-M1  
NO+NC  
NO  
-
E2E-X4B3D12-M1  
E2E-X4B1DL12-M1  
E2E-X4B2L12-M1  
E2E-X4B3DL12-M1  
E2E-X4C312-M1  
M12 Connector  
E2E-X4B1TL12-M1  
E2E-X4C1L12-M1  
E2E-X4C2L12-M1  
E2E-X4C3L12-M1  
NC  
-
-
NO+NC  
25  
E2E/E2EQ NEXT Series  
BASIC Model  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X8B1D18 2M  
--- *4  
NO  
NC  
E2E-X8B1T18 2M  
E2E-X8C118 2M  
55 mm  
*2  
-
E2E-X8B218 2M  
E2E-X8C218 2M  
NO+NC  
NO  
-
E2E-X8B3D18 2M  
E2E-X8C318 2M  
Pre-wired (2 m) *1  
E2E-X8B1TL18 2M  
E2E-X8B1DL18 2M  
E2E-X8C1L18 2M  
77 mm  
NC  
-
E2E-X8B2L18 2M  
E2E-X8C2L18 2M  
NO+NC  
NO  
-
E2E-X8B3DL18 2M  
E2E-X8C3L18 2M  
E2E-X8B1T18-M1TJ 0.3M  
E2E-X8B1D18-M1TJ 0.3M  
E2E-X8B218-M1TJ 0.3M  
E2E-X8B3D18-M1TJ 0.3M  
E2E-X8B1DL18-M1TJ 0.3M  
E2E-X8B2L18-M1TJ 0.3M  
E2E-X8B3DL18-M1TJ 0.3M  
E2E-X8B1D18-M1  
E2E-X8C118-M1TJ 0.3M  
E2E-X8C218-M1TJ 0.3M  
E2E-X8C318-M1TJ 0.3M  
E2E-X8C1L18-M1TJ 0.3M  
E2E-X8C2L18-M1TJ 0.3M  
E2E-X8C3L18-M1TJ 0.3M  
E2E-X8C118-M1  
55 mm  
*3  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M18  
(8 mm)  
E2E-X8B1TL18-M1TJ 0.3M  
77 mm  
53 mm  
75 mm  
NC  
-
NO+NC  
NO  
-
E2E-X8B1T18-M1  
NC  
-
E2E-X8B218-M1  
E2E-X8C218-M1  
NO+NC  
NO  
-
E2E-X8B3D18-M1  
E2E-X8C318-M1  
M12 Connector  
E2E-X8B1TL18-M1  
E2E-X8B1DL18-M1  
E2E-X8C1L18-M1  
NC  
-
E2E-X8B2L18-M1  
E2E-X8C2L18-M1  
NO+NC  
NO  
-
E2E-X8B3DL18-M1  
E2E-X8C3L18-M1  
E2E-X15B1T30 2M  
E2E-X15B1D30 2M  
E2E-X15C130 2M  
60 mm  
*2  
NC  
-
E2E-X15B230 2M  
E2E-X15C230 2M  
NO+NC  
NO  
-
E2E-X15B3D30 2M  
E2E-X15C330 2M  
Pre-wired (2 m) *1  
E2E-X15B1TL30 2M  
E2E-X15B1DL30 2M  
E2E-X15B2L30 2M  
E2E-X15C1L30 2M  
E2E-X15C2L30 2M  
E2E-X15C3L30 2M  
E2E-X15C130-M1TJ 0.3M  
E2E-X15C230-M1TJ 0.3M  
E2E-X15C330-M1TJ 0.3M  
E2E-X15C1L30-M1TJ 0.3M  
E2E-X15C2L30-M1TJ 0.3M  
E2E-X15C3L30-M1TJ 0.3M  
E2E-X15C130-M1  
82 mm  
NC  
-
NO+NC  
NO  
-
E2E-X15B3DL30 2M  
E2E-X15B1D30-M1TJ 0.3M  
E2E-X15B230-M1TJ 0.3M  
E2E-X15B3D30-M1TJ 0.3M  
E2E-X15B1DL30-M1TJ 0.3M  
E2E-X15B2L30-M1TJ 0.3M  
E2E-X15B3DL30-M1TJ 0.3M  
E2E-X15B1D30-M1  
E2E-X15B1T30-M1TJ 0.3M  
60 mm  
*3  
NC  
-
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
M30  
(15 mm)  
E2E-X15B1TL30-M1TJ 0.3M  
82 mm  
58 mm  
80 mm  
NC  
-
NO+NC  
NO  
-
E2E-X15B1T30-M1  
NC  
-
E2E-X15B230-M1  
E2E-X15C230-M1  
NO+NC  
NO  
-
E2E-X15B3D30-M1  
E2E-X15C330-M1  
M12 Connector  
E2E-X15B1TL30-M1  
E2E-X15B1DL30-M1  
E2E-X15B2L30-M1  
E2E-X15C1L30-M1  
E2E-X15C2L30-M1  
E2E-X15C3L30-M1  
NC  
-
-
NO+NC  
E2E-X15B3DL30-M1  
*1. Models with 5-m cable length are also available (Example: E2E-X2B1D8 5M)  
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X2B1D8-R 2M/  
E2E-X2B1D8-R 5M)  
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-  
X4B1T12-M1TJR 0.3M)  
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
26  
E2E/E2EQ NEXT Series  
BASIC Model  
E2E NEXT Series (Double distance model)  
DC 3-wire [Refer to Dimensions on page 65.]  
Unshielded  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X4MB1D8 2M  
--- *4  
NO  
NC  
E2E-X4MB1T8 2M  
E2E-X4MC18 2M  
38 mm  
*2  
-
E2E-X4MB28 2M  
E2E-X4MC28 2M  
Pre-wired (2 m) *1  
NO  
E2E-X4MB1TL8 2M  
E2E-X4MB1DL8 2M  
E2E-X4MB2L8 2M  
E2E-X4MC1L8 2M  
48 mm  
NC  
-
E2E-X4MC2L8 2M  
NO  
E2E-X4MB1T8-M1TJ 0.3M  
E2E-X4MB1D8-M1TJ 0.3M  
E2E-X4MB28-M1TJ 0.3M  
E2E-X4MB1DL8-M1TJ 0.3M  
E2E-X4MB2L8-M1TJ 0.3M  
E2E-X4MB1D8-M1  
E2E-X4MC18-M1TJ 0.3M  
E2E-X4MC28-M1TJ 0.3M  
E2E-X4MC1L8-M1TJ 0.3M  
E2E-X4MC2L8-M1TJ 0.3M  
E2E-X4MC18-M1  
38 mm  
*3  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NC  
-
NO  
E2E-X4MB1TL8-M1TJ 0.3M  
48 mm  
43 mm  
NC  
-
NO  
E2E-X4MB1T8-M1  
NC  
-
E2E-X4MB28-M1  
E2E-X4MC28-M1  
M8  
(4 mm)  
M12 Connector  
NO  
E2E-X4MB1TL8-M1  
E2E-X4MB1DL8-M1  
E2E-X4MB2L8-M1  
E2E-X4MC1L8-M1  
E2E-X4MC2L8-M1  
E2E-X4MC3L8-M1  
E2E-X4MC18-M3  
53 mm  
NC  
-
NO+NC  
NO  
-
E2E-X4MB3DL8-M1  
E2E-X4MB1D8-M3  
E2E-X4MB1T8-M3  
39 mm  
49 mm  
39 mm  
49 mm  
NC  
-
E2E-X4MB28-M3  
E2E-X4MC28-M3  
M8 Connector  
(4-pin)  
NO  
E2E-X4MB1TL8-M3  
E2E-X4MB1DL8-M3  
E2E-X4MB2L8-M3  
E2E-X4MC1L8-M3  
E2E-X4MC2L8-M3  
E2E-X4MC18-M5  
NC  
-
NO  
E2E-X4MB1T8-M5  
E2E-X4MB1D8-M5  
NC  
-
E2E-X4MB28-M5  
E2E-X4MC28-M5  
M8 Connector  
(3-pin)  
NO  
E2E-X4MB1TL8-M5  
E2E-X4MB1DL8-M5  
E2E-X4MB2L8-M5  
E2E-X4MC1L8-M5  
E2E-X4MC2L8-M5  
E2E-X8MC112 2M  
NC  
-
NO  
E2E-X8MB1T12 2M  
E2E-X8MB1D12 2M  
E2E-X8MB212 2M  
47 mm  
*2  
NC  
-
E2E-X8MC212 2M  
NO+NC  
NO  
-
E2E-X8MB3D12 2M  
E2E-X8MB1DL12 2M  
E2E-X8MB2L12 2M  
E2E-X8MB3DL12 2M  
E2E-X8MB1D12-M1TJ 0.3M  
E2E-X8MB212-M1TJ 0.3M  
E2E-X8MB3D12-M1TJ 0.3M  
E2E-X8MB1DL12-M1TJ 0.3M  
E2E-X8MB2L12-M1TJ 0.3M  
E2E-X8MB3DL12-M1TJ 0.3M  
E2E-X8MB1D12-M1  
E2E-X8MB212-M1  
E2E-X8MC312 2M  
Pre-wired (2 m) *1  
E2E-X8MB1TL12 2M  
E2E-X8MC1L12 2M  
E2E-X8MC2L12 2M  
E2E-X8MC3L12 2M  
E2E-X8MC112-M1TJ 0.3M  
E2E-X8MC212-M1TJ 0.3M  
E2E-X8MC312-M1TJ 0.3M  
E2E-X8MC1L12-M1TJ 0.3M  
E2E-X8MC2L12-M1TJ 0.3M  
E2E-X8MC3L12-M1TJ 0.3M  
E2E-X8MC112-M1  
69 mm  
NC  
-
NO+NC  
NO  
-
E2E-X8MB1T12-M1TJ 0.3M  
47 mm  
*3  
NC  
-
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
M12  
(8 mm)  
E2E-X8MB1TL12-M1TJ 0.3M  
69 mm  
48 mm  
70 mm  
NC  
-
NO+NC  
NO  
-
E2E-X8MB1T12-M1  
NC  
-
E2E-X8MC212-M1  
NO+NC  
NO  
-
E2E-X8MB3D12-M1  
E2E-X8MB1DL12-M1  
E2E-X8MB2L12-M1  
E2E-X8MB3DL12-M1  
E2E-X8MC312-M1  
M12 Connector  
E2E-X8MB1TL12-M1  
E2E-X8MC1L12-M1  
E2E-X8MC2L12-M1  
E2E-X8MC3L12-M1  
NC  
-
-
NO+NC  
27  
E2E/E2EQ NEXT Series  
BASIC Model  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X16MB1D18 2M  
--- *4  
NO  
NC  
E2E-X16MB1T18 2M  
E2E-X16MC118 2M  
55 mm  
*2  
-
E2E-X16MB218 2M  
E2E-X16MC218 2M  
NO+NC  
NO  
-
E2E-X16MB3D18 2M  
E2E-X16MC318 2M  
Pre-wired (2 m) *1  
E2E-X16MB1TL18 2M  
E2E-X16MB1DL18 2M  
E2E-X16MB2L18 2M  
E2E-X16MC1L18 2M  
E2E-X16MC2L18 2M  
E2E-X16MC3L18 2M  
E2E-X16MC118-M1TJ 0.3M  
E2E-X16MC218-M1TJ 0.3M  
E2E-X16MC318-M1TJ 0.3M  
E2E-X16MC1L18-M1TJ 0.3M  
E2E-X16MC2L18-M1TJ 0.3M  
E2E-X16MC3L18-M1TJ 0.3M  
E2E-X16MC118-M1  
77 mm  
NC  
-
-
NO+NC  
NO  
E2E-X16MB3DL18 2M  
E2E-X16MB1D18-M1TJ 0.3M  
E2E-X16MB218-M1TJ 0.3M  
E2E-X16MB3D18-M1TJ 0.3M  
E2E-X16MB1DL18-M1TJ 0.3M  
E2E-X16MB2L18-M1TJ 0.3M  
E2E-X16MB3DL18-M1TJ 0.3M  
E2E-X16MB1D18-M1  
E2E-X16MB1T18-M1TJ 0.3M  
55 mm  
*3  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M18  
(16 mm)  
E2E-X16MB1TL18-M1TJ 0.3M  
77 mm  
53 mm  
75 mm  
NC  
-
NO+NC  
NO  
-
E2E-X16MB1T18-M1  
NC  
-
E2E-X16MB218-M1  
E2E-X16MC218-M1  
NO+NC  
NO  
-
E2E-X16MB3D18-M1  
E2E-X16MC318-M1  
M12 Connector  
E2E-X16MB1TL18-M1  
E2E-X16MB1DL18-M1  
E2E-X16MB2L18-M1  
E2E-X16MC1L18-M1  
E2E-X16MC2L18-M1  
E2E-X16MC3L18-M1  
E2E-X30MC1L30 2M  
E2E-X30MC2L30 2M  
E2E-X30MC3L30 2M  
E2E-X30MC1L30-M1TJ 0.3M  
E2E-X30MC2L30-M1TJ 0.3M  
E2E-X30MC3L30-M1TJ 0.3M  
E2E-X30MC1L30-M1  
E2E-X30MC2L30-M1  
E2E-X30MC3L30-M1  
NC  
-
NO+NC  
NO  
-
E2E-X16MB3DL18-M1  
E2E-X30MB1DL30 2M  
E2E-X30MB2L30 2M  
E2E-X30MB1TL30 2M  
82 mm  
*2  
Pre-wired (2 m) *1  
NC  
-
NO+NC  
NO  
-
E2E-X30MB3DL30 2M  
E2E-X30MB1DL30-M1TJ 0.3M  
E2E-X30MB2L30-M1TJ 0.3M  
E2E-X30MB3DL30-M1TJ 0.3M  
E2E-X30MB1DL30-M1  
E2E-X30MB2L30-M1  
E2E-X30MB1TL30-M1TJ 0.3M  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
M30  
(30 mm)  
82 mm  
*3  
NC  
-
NO+NC  
NO  
-
E2E-X30MB1TL30-M1  
M12 Connector  
80 mm  
NC  
-
-
NO+NC  
E2E-X30MB3DL30-M1  
*1. Models with 5-m cable length are also available (Example: E2E-X8MB1D12 5M)  
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X8MB1D12-R 2M/  
E2E-X8MB1D12-R 5M)  
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-  
X8MB1D12-M1TJR 0.3M)  
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
28  
E2E/E2EQ NEXT Series  
BASIC Model  
E2E NEXT Series (Single distance model)  
DC 3-wire [Refer to Dimensions on page 65.]  
Shielded  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X1R5B1D8 2M  
E2E-X1R5B28 2M  
--- *4  
NO  
NC  
E2E-X1R5B1T8 2M  
E2E-X1R5C18 2M  
38 mm  
*2  
-
E2E-X1R5C28 2M  
Pre-wired (2 m) *1  
NO  
E2E-X1R5B1TL8 2M  
E2E-X1R5B1DL8 2M  
E2E-X1R5B2L8 2M  
E2E-X1R5B1D8-M1TJ 0.3M  
E2E-X1R5B28-M1TJ 0.3M  
E2E-X1R5B1DL8-M1TJ 0.3M  
E2E-X1R5B2L8-M1TJ 0.3M  
E2E-X1R5B1D8-M1  
E2E-X1R5B28-M1  
E2E-X1R5C1L8 2M  
E2E-X1R5C2L8 2M  
E2E-X1R5C18-M1TJ 0.3M  
E2E-X1R5C28-M1TJ 0.3M  
E2E-X1R5C1L8-M1TJ 0.3M  
E2E-X1R5C2L8-M1TJ 0.3M  
E2E-X1R5C18-M1  
48 mm  
NC  
-
NO  
E2E-X1R5B1T8-M1TJ 0.3M  
-
38 mm  
*3  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NC  
NO  
E2E-X1R5B1TL8-M1TJ 0.3M  
48 mm  
43 mm  
NC  
-
NO  
E2E-X1R5B1T8-M1  
NC  
-
E2E-X1R5C28-M1  
M8  
(1.5 mm)  
M12 Connector  
NO  
E2E-X1R5B1TL8-M1  
E2E-X1R5B1DL8-M1  
E2E-X1R5B2L8-M1  
E2E-X1R5B3DL8-M1  
E2E-X1R5B1D8-M3  
E2E-X1R5B28-M3  
E2E-X1R5C1L8-M1  
E2E-X1R5C2L8-M1  
E2E-X1R5C3L8-M1  
E2E-X1R5C18-M3  
53 mm  
NC  
-
NO+NC  
NO  
-
E2E-X1R5B1T8-M3  
39 mm  
49 mm  
39 mm  
49 mm  
NC  
-
E2E-X1R5C28-M3  
M8 Connector  
(4-pin)  
NO  
E2E-X1R5B1TL8-M3  
E2E-X1R5B1DL8-M3  
E2E-X1R5B2L8-M3  
E2E-X1R5B1D8-M5  
E2E-X1R5B28-M5  
E2E-X1R5C1L8-M3  
E2E-X1R5C2L8-M3  
E2E-X1R5C18-M5  
NC  
-
NO  
E2E-X1R5B1T8-M5  
NC  
-
E2E-X1R5C28-M5  
M8 Connector  
(3-pin)  
NO  
E2E-X1R5B1TL8-M5  
E2E-X1R5B1DL8-M5  
E2E-X1R5B2L8-M5  
E2E-X2B1D12 2M  
E2E-X1R5C1L8-M5  
E2E-X1R5C2L8-M5  
E2E-X2C112 2M  
NC  
-
NO  
E2E-X2B1T12 2M  
47 mm  
*2  
NC  
-
E2E-X2B212 2M  
E2E-X2C212 2M  
NO+NC  
NO  
-
E2E-X2B3D12 2M  
E2E-X2C312 2M  
Pre-wired (2 m) *1  
E2E-X2B1TL12 2M  
E2E-X2B1DL12 2M  
E2E-X2B2L12 2M  
E2E-X2C1L12 2M  
69 mm  
NC  
-
E2E-X2C2L12 2M  
NO+NC  
NO  
-
E2E-X2B3DL12 2M  
E2E-X2B1D12-M1TJ 0.3M  
E2E-X2B212-M1TJ 0.3M  
E2E-X2B3D12-M1TJ 0.3M  
E2E-X2B1DL12-M1TJ 0.3M  
E2E-X2B2L12-M1TJ 0.3M  
E2E-X2B3DL12-M1TJ 0.3M  
E2E-X2B1D12-M1  
E2E-X2C3L12 2M  
E2E-X2B1T12-M1TJ 0.3M  
E2E-X2C112-M1TJ 0.3M  
E2E-X2C212-M1TJ 0.3M  
E2E-X2C312-M1TJ 0.3M  
E2E-X2C1L12-M1TJ 0.3M  
E2E-X2C2L12-M1TJ 0.3M  
E2E-X2C3L12-M1TJ 0.3M  
E2E-X2C112-M1  
47 mm  
*3  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M12  
(2 mm)  
E2E-X2B1TL12-M1TJ 0.3M  
69 mm  
48 mm  
70 mm  
NC  
-
NO+NC  
NO  
-
E2E-X2B1T12-M1  
NC  
-
E2E-X2B212-M1  
E2E-X2C212-M1  
NO+NC  
NO  
-
E2E-X2B3D12-M1  
E2E-X2C312-M1  
M12 Connector  
E2E-X2B1TL12-M1  
E2E-X2B1DL12-M1  
E2E-X2B2L12-M1  
E2E-X2C1L12-M1  
NC  
-
-
E2E-X2C2L12-M1  
NO+NC  
E2E-X2B3DL12-M1  
E2E-X2C3L12-M1  
29  
E2E/E2EQ NEXT Series  
BASIC Model  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X5B1D18 2M  
--- *4  
NO  
NC  
E2E-X5B1T18 2M  
E2E-X5C118 2M  
55 mm  
*2  
-
E2E-X5B218 2M  
E2E-X5C218 2M  
NO+NC  
NO  
-
E2E-X5B3D18 2M  
E2E-X5C318 2M  
Pre-wired (2 m) *1  
E2E-X5B1TL18 2M  
E2E-X5B1DL18 2M  
E2E-X5C1L18 2M  
77 mm  
NC  
-
E2E-X5B2L18 2M  
E2E-X5C2L18 2M  
NO+NC  
NO  
-
E2E-X5B3DL18 2M  
E2E-X5C3L18 2M  
E2E-X5B1T18-M1TJ 0.3M  
E2E-X5B1D18-M1TJ 0.3M  
E2E-X5B218-M1TJ 0.3M  
E2E-X5B3D18-M1TJ 0.3M  
E2E-X5B1DL18-M1TJ 0.3M  
E2E-X5B2L18-M1TJ 0.3M  
E2E-X5B3DL18-M1TJ 0.3M  
E2E-X5B1D18-M1  
E2E-X5C118-M1TJ 0.3M  
E2E-X5C218-M1TJ 0.3M  
E2E-X5C318-M1TJ 0.3M  
E2E-X5C1L18-M1TJ 0.3M  
E2E-X5C2L18-M1TJ 0.3M  
E2E-X5C3L18-M1TJ 0.3M  
E2E-X5C118-M1  
55 mm  
*3  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M18  
(5 mm)  
E2E-X5B1TL18-M1TJ 0.3M  
77 mm  
53 mm  
75 mm  
NC  
-
NO+NC  
NO  
-
E2E-X5B1T18-M1  
NC  
-
E2E-X5B218-M1  
E2E-X5C218-M1  
NO+NC  
NO  
-
E2E-X5B3D18-M1  
E2E-X5C318-M1  
M12 Connector  
E2E-X5B1TL18-M1  
E2E-X5B1DL18-M1  
E2E-X5C1L18-M1  
NC  
-
E2E-X5B2L18-M1  
E2E-X5C2L18-M1  
NO+NC  
NO  
-
E2E-X5B3DL18-M1  
E2E-X5C3L18-M1  
E2E-X10B1T30 2M  
E2E-X10B1D30 2M  
E2E-X10C130 2M  
60 mm  
*2  
NC  
-
E2E-X10B230 2M  
E2E-X10C230 2M  
NO+NC  
NO  
-
E2E-X10B3D30 2M  
E2E-X10C330 2M  
Pre-wired (2 m) *1  
E2E-X10B1TL30 2M  
E2E-X10B1DL30 2M  
E2E-X10B2L30 2M  
E2E-X10C1L30 2M  
E2E-X10C2L30 2M  
E2E-X10C3L30 2M  
E2E-X10C130-M1TJ 0.3M  
E2E-X10C230-M1TJ 0.3M  
E2E-X10C330-M1TJ 0.3M  
E2E-X10C1L30-M1TJ 0.3M  
E2E-X10C2L30-M1TJ 0.3M  
E2E-X10C3L30-M1TJ 0.3M  
E2E-X10C130-M1  
82 mm  
NC  
-
NO+NC  
NO  
-
E2E-X10B3DL30 2M  
E2E-X10B1D30-M1TJ 0.3M  
E2E-X10B230-M1TJ 0.3M  
E2E-X10B3D30-M1TJ 0.3M  
E2E-X10B1DL30-M1TJ 0.3M  
E2E-X10B2L30-M1TJ 0.3M  
E2E-X10B3DL30-M1TJ 0.3M  
E2E-X10B1D30-M1  
E2E-X10B1T30-M1TJ 0.3M  
60 mm  
*3  
NC  
-
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
M30  
(10 mm)  
E2E-X10B1TL30-M1TJ 0.3M  
82 mm  
58 mm  
80 mm  
NC  
-
NO+NC  
NO  
-
E2E-X10B1T30-M1  
NC  
-
E2E-X10B230-M1  
E2E-X10C230-M1  
NO+NC  
NO  
-
E2E-X10B3D30-M1  
E2E-X10C330-M1  
M12 Connector  
E2E-X10B1TL30-M1  
E2E-X10B1DL30-M1  
E2E-X10B2L30-M1  
E2E-X10C1L30-M1  
E2E-X10C2L30-M1  
E2E-X10C3L30-M1  
NC  
-
-
NO+NC  
E2E-X10B3DL30-M1  
*1. Models with 5-m cable length are also available (Example: E2E-X2B1D12 5M)  
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X2B1D12-R 2M/  
E2E-X2B1D12-R 5M)  
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-  
X2B1D12-M1TJR 0.3M)  
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
30  
E2E/E2EQ NEXT Series  
BASIC Model  
E2E NEXT Series (Single distance model)  
DC 3-wire [Refer to Dimensions on page 65.]  
Unshielded  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X2MB1D8 2M  
--- *4  
NO  
NC  
E2E-X2MB1T8 2M  
E2E-X2MC18 2M  
38 mm  
*2  
-
E2E-X2MB28 2M  
E2E-X2MC28 2M  
Pre-wired (2 m) *1  
NO  
E2E-X2MB1TL8 2M  
E2E-X2MB1DL8 2M  
E2E-X2MB2L8 2M  
E2E-X2MC1L8 2M  
48 mm  
NC  
-
E2E-X2MC2L8 2M  
NO  
E2E-X2MB1T8-M1TJ 0.3M  
E2E-X2MB1D8-M1TJ 0.3M  
E2E-X2MB28-M1TJ 0.3M  
E2E-X2MB1DL8-M1TJ 0.3M  
E2E-X2MB2L8-M1TJ 0.3M  
E2E-X2MB1D8-M1  
E2E-X2MC18-M1TJ 0.3M  
E2E-X2MC28-M1TJ 0.3M  
E2E-X2MC1L8-M1TJ 0.3M  
E2E-X2MC2L8-M1TJ 0.3M  
E2E-X2MC18-M1  
38 mm  
*3  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NC  
-
NO  
E2E-X2MB1TL8-M1TJ 0.3M  
48 mm  
43 mm  
NC  
-
NO  
E2E-X2MB1T8-M1  
NC  
-
E2E-X2MB28-M1  
E2E-X2MC28-M1  
M8  
(2mm)  
M12 Connector  
NO  
E2E-X2MB1TL8-M1  
E2E-X2MB1DL8-M1  
E2E-X2MB2L8-M1  
E2E-X2MC1L8-M1  
E2E-X2MC2L8-M1  
E2E-X2MC3L8-M1  
E2E-X2MC18-M3  
53 mm  
NC  
-
NO+NC  
NO  
-
E2E-X2MB3DL8-M1  
E2E-X2MB1D8-M3  
E2E-X2MB1T8-M3  
39 mm  
49 mm  
39 mm  
49 mm  
NC  
-
E2E-X2MB28-M3  
E2E-X2MC28-M3  
M8 Connector  
(4-pin)  
NO  
E2E-X2MB1TL8-M3  
E2E-X2MB1DL8-M3  
E2E-X2MB2L8-M3  
E2E-X2MC1L8-M3  
E2E-X2MC2L8-M3  
E2E-X2MC18-M5  
NC  
-
NO  
E2E-X2MB1T8-M5  
E2E-X2MB1D8-M5  
NC  
-
E2E-X2MB28-M5  
E2E-X2MC28-M5  
M8 Connector  
(3-pin)  
NO  
E2E-X2MB1TL8-M5  
E2E-X2MB1DL8-M5  
E2E-X2MB2L8-M5  
E2E-X2MC1L8-M5  
E2E-X2MC2L8-M5  
E2E-X5MC112 2M  
NC  
-
NO  
E2E-X5MB1T12 2M  
E2E-X5MB1D12 2M  
E2E-X5MB212 2M  
47 mm  
*2  
NC  
-
E2E-X5MC212 2M  
NO+NC  
NO  
-
E2E-X5MB3D12 2M  
E2E-X5MB1DL12 2M  
E2E-X5MB2L12 2M  
E2E-X5MB3DL12 2M  
E2E-X5MB1D12-M1TJ 0.3M  
E2E-X5MB212-M1TJ 0.3M  
E2E-X5MB3D12-M1TJ 0.3M  
E2E-X5MB1DL12-M1TJ 0.3M  
E2E-X5MB2L12-M1TJ 0.3M  
E2E-X5MB3DL12-M1TJ 0.3M  
E2E-X5MB1D12-M1  
E2E-X5MB212-M1  
E2E-X5MC312 2M  
Pre-wired (2 m) *1  
E2E-X5MB1TL12 2M  
E2E-X5MC1L12 2M  
E2E-X5MC2L12 2M  
E2E-X5MC3L12 2M  
E2E-X5MC112-M1TJ 0.3M  
E2E-X5MC212-M1TJ 0.3M  
E2E-X5MC312-M1TJ 0.3M  
E2E-X5MC1L12-M1TJ 0.3M  
E2E-X5MC2L12-M1TJ 0.3M  
E2E-X5MC3L12-M1TJ 0.3M  
E2E-X5MC112-M1  
69 mm  
NC  
-
NO+NC  
NO  
-
E2E-X5MB1T12-M1TJ 0.3M  
47 mm  
*3  
NC  
-
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
M12  
(5mm)  
E2E-X5MB1TL12-M1TJ 0.3M  
69 mm  
48 mm  
70 mm  
NC  
-
NO+NC  
NO  
-
E2E-X5MB1T12-M1  
NC  
-
E2E-X5MC212-M1  
NO+NC  
NO  
-
E2E-X5MB3D12-M1  
E2E-X5MB1DL12-M1  
E2E-X5MB2L12-M1  
E2E-X5MB3DL12-M1  
E2E-X5MC312-M1  
M12 Connector  
E2E-X5MB1TL12-M1  
E2E-X5MC1L12-M1  
E2E-X5MC2L12-M1  
E2E-X5MC3L12-M1  
NC  
-
-
NO+NC  
31  
E2E/E2EQ NEXT Series  
BASIC Model  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *4  
E2E-X10MB1D18 2M  
--- *4  
NO  
NC  
E2E-X10MB1T18 2M  
E2E-X10MC118 2M  
55 mm  
*2  
-
E2E-X10MB218 2M  
E2E-X10MC218 2M  
NO+NC  
NO  
-
E2E-X10MB3D18 2M  
E2E-X10MC318 2M  
Pre-wired (2 m) *1  
E2E-X10MB1TL18 2M  
E2E-X10MB1DL18 2M  
E2E-X10MB2L18 2M  
E2E-X10MC1L18 2M  
E2E-X10MC2L18 2M  
E2E-X10MC3L18 2M  
E2E-X10MC118-M1TJ 0.3M  
E2E-X10MC218-M1TJ 0.3M  
E2E-X10MC318-M1TJ 0.3M  
E2E-X10MC1L18-M1TJ 0.3M  
E2E-X10MC2L18-M1TJ 0.3M  
E2E-X10MC3L18-M1TJ 0.3M  
E2E-X10MC118-M1  
77 mm  
NC  
-
-
NO+NC  
NO  
E2E-X10MB3DL18 2M  
E2E-X10MB1D18-M1TJ 0.3M  
E2E-X10MB218-M1TJ 0.3M  
E2E-X10MB3D18-M1TJ 0.3M  
E2E-X10MB1DL18-M1TJ 0.3M  
E2E-X10MB2L18-M1TJ 0.3M  
E2E-X10MB3DL18-M1TJ 0.3M  
E2E-X10MB1D18-M1  
E2E-X10MB1T18-M1TJ 0.3M  
55 mm  
*3  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M18  
(10mm)  
E2E-X10MB1TL18-M1TJ 0.3M  
77 mm  
53 mm  
75 mm  
NC  
-
NO+NC  
NO  
-
E2E-X10MB1T18-M1  
NC  
-
E2E-X10MB218-M1  
E2E-X10MC218-M1  
NO+NC  
NO  
-
E2E-X10MB3D18-M1  
E2E-X10MC318-M1  
M12 Connector  
E2E-X10MB1TL18-M1  
E2E-X10MB1DL18-M1  
E2E-X10MB2L18-M1  
E2E-X10MC1L18-M1  
E2E-X10MC2L18-M1  
E2E-X10MC3L18-M1  
E2E-X18MC130 2M  
NC  
-
NO+NC  
NO  
-
E2E-X10MB3DL18-M1  
E2E-X18MB1D30 2M  
E2E-X18MB1T30 2M  
60 mm  
*2  
NC  
-
E2E-X18MB230 2M  
E2E-X18MC230 2M  
NO+NC  
NO  
-
E2E-X18MB3D30 2M  
E2E-X18MC330 2M  
Pre-wired (2 m) *1  
E2E-X18MB1TL30 2M  
E2E-X18MB1DL30 2M  
E2E-X18MB2L30 2M  
E2E-X18MC1L30 2M  
E2E-X18MC2L30 2M  
E2E-X18MC3L30 2M  
E2E-X18MC130-M1TJ 0.3M  
E2E-X18MC230-M1TJ 0.3M  
E2E-X18MC330-M1TJ 0.3M  
E2E-X18MC1L30-M1TJ 0.3M  
E2E-X18MC2L30-M1TJ 0.3M  
E2E-X18MC3L30-M1TJ 0.3M  
E2E-X18MC130-M1  
82 mm  
NC  
-
NO+NC  
NO  
-
E2E-X18MB3DL30 2M  
E2E-X18MB1D30-M1TJ 0.3M  
E2E-X18MB230-M1TJ 0.3M  
E2E-X18MB3D30-M1TJ 0.3M  
E2E-X18MB1DL30-M1TJ 0.3M  
E2E-X18MB2L30-M1TJ 0.3M  
E2E-X18MB3DL30-M1TJ 0.3M  
E2E-X18MB1D30-M1  
E2E-X18MB1T30-M1TJ 0.3M  
60 mm  
*3  
NC  
-
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO+NC  
NO  
-
M30  
(18mm)  
E2E-X18MB1TL30-M1TJ 0.3M  
82 mm  
58 mm  
80 mm  
NC  
-
NO+NC  
NO  
-
E2E-X18MB1T30-M1  
NC  
-
E2E-X18MB230-M1  
E2E-X18MC230-M1  
NO+NC  
NO  
-
E2E-X18MB3D30-M1  
E2E-X18MC330-M1  
M12 Connector  
E2E-X18MB1TL30-M1  
E2E-X18MB1DL30-M1  
E2E-X18MB2L30-M1  
E2E-X18MC1L30-M1  
E2E-X18MC2L30-M1  
E2E-X18MC3L30-M1  
NC  
-
-
NO+NC  
E2E-X18MB3DL30-M1  
*1. Models with 5-m cable length are also available (Example: E2E-X5MB1D12 5M)  
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X5MB1D12-R 2M/  
E2E-X5MB1D12-R 5M)  
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with R" in the model number. (Example: E2E-  
X5MB1D12-M1TJR 2M)  
*4. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
32  
E2E/E2EQ NEXT Series  
BASIC Model  
E2EQ NEXT Series (Spatter-resistant Double distance model)  
DC 3-wire [Refer to Dimensions on page 65.]  
Shielded  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
IO-Link (COM3)  
IO-Link (COM2) *2  
--- *2  
E2EQ-X2C18 2M  
E2EQ-X2C28 2M  
NO  
NC  
E2EQ-X2B1T8 2M  
-
E2EQ-X2B1D8 2M  
E2EQ-X2B28 2M  
Pre-wired (2 m) *1 38 mm  
M12 Pre-wired  
NO  
NC  
E2EQ-X2B1T8-M1TJ 0.3M  
-
E2EQ-X2B1D8-M1TJ 0.3M  
E2EQ-X2B28-M1TJ 0.3M  
E2EQ-X2C18-M1TJ 0.3M  
E2EQ-X2C28-M1TJ 0.3M  
M8  
(2 mm)  
Smartclick  
38 mm  
Connector (0.3 m)  
NO  
NC  
E2EQ-X2B1T8-M1  
E2EQ-X2B1D8-M1  
E2EQ-X2C18-M1  
M12 Connector  
43 mm  
-
E2EQ-X2B28-M1  
E2EQ-X2C28-M1  
NO  
E2EQ-X4B1T12 2M  
E2EQ-X4B1D12 2M  
E2EQ-X4C112 2M  
Pre-wired (2 m) *1 47 mm  
M12 Pre-wired  
NC  
-
E2EQ-X4B212 2M  
E2EQ-X4C212 2M  
NO+NC  
NO  
-
E2EQ-X4B3D12 2M  
E2EQ-X4C312 2M  
E2EQ-X4B1T12-M1TJ 0.3M  
E2EQ-X4B1D12-M1TJ 0.3M  
E2EQ-X4B212-M1TJ 0.3M  
E2EQ-X4B3D12-M1TJ 0.3M  
E2EQ-X4B1D12-M1  
E2EQ-X4C112-M1TJ 0.3M  
E2EQ-X4C212-M1TJ 0.3M  
E2EQ-X4C312-M1TJ 0.3M  
E2EQ-X4C112-M1  
M12  
(4 mm)  
Smartclick  
47 mm  
NC  
-
Connector (0.3 m)  
NO+NC  
NO  
-
E2EQ-X4B1T12-M1  
M12 Connector  
48 mm  
NC  
-
E2EQ-X4B212-M1  
E2EQ-X4C212-M1  
NO+NC  
NO  
-
E2EQ-X4B3D12-M1  
E2EQ-X4C312-M1  
E2EQ-X8B1T18 2M  
E2EQ-X8B1D18 2M  
E2EQ-X8C118 2M  
Pre-wired (2 m) *1 55 mm  
M12 Pre-wired  
NC  
-
E2EQ-X8B218 2M  
E2EQ-X8C218 2M  
NO+NC  
NO  
-
E2EQ-X8B3D18 2M  
E2EQ-X8C318 2M  
E2EQ-X8B1T18-M1TJ 0.3M  
E2EQ-X8B1D18-M1TJ 0.3M  
E2EQ-X8B218-M1TJ 0.3M  
E2EQ-X8B3D18-M1TJ 0.3M  
E2EQ-X8B1D18-M1  
E2EQ-X8C118-M1TJ 0.3M  
E2EQ-X8C218-M1TJ 0.3M  
E2EQ-X8C318-M1TJ 0.3M  
E2EQ-X8C118-M1  
M18  
(8 mm)  
Smartclick  
55 mm  
NC  
-
Connector (0.3 m)  
NO+NC  
NO  
-
E2EQ-X8B1T18-M1  
M12 Connector  
53 mm  
NC  
-
E2EQ-X8B218-M1  
E2EQ-X8C218-M1  
NO+NC  
NO  
-
E2EQ-X8B3D18-M1  
E2EQ-X8C318-M1  
E2EQ-X15B1T30 2M  
E2EQ-X15B1D30 2M  
E2EQ-X15B230 2M  
E2EQ-X15C130 2M  
E2EQ-X15C230 2M  
E2EQ-X15C330 2M  
E2EQ-X15C130-M1TJ 0.3M  
E2EQ-X15C230-M1TJ 0.3M  
E2EQ-X15C330-M1TJ 0.3M  
E2EQ-X15C130-M1  
E2EQ-X15C230-M1  
E2EQ-X15C330-M1  
Pre-wired (2 m) *1 60 mm  
M12 Pre-wired  
NC  
-
-
NO+NC  
NO  
E2EQ-X15B3D30 2M  
E2EQ-X15B1D30-M1TJ 0.3M  
E2EQ-X15B230-M1TJ 0.3M  
E2EQ-X15B3D30-M1TJ 0.3M  
E2EQ-X15B1D30-M1  
E2EQ-X15B230-M1  
E2EQ-X15B1T30-M1TJ 0.3M  
M30  
(15 mm)  
Smartclick  
60 mm  
NC  
-
Connector (0.3 m)  
NO+NC  
NO  
-
E2EQ-X15B1T30-M1  
M12 Connector  
58 mm  
NC  
-
-
NO+NC  
E2EQ-X15B3D30-M1  
*1. Models with 5-m cable length are also available (Example: E2EQ-X6B1D12 5M)  
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
33  
E2E/E2EQ NEXT Series  
BASIC Model  
E2EQ NEXT Series (Spatter-resistant Single distance model)  
DC 3-wire [Refer to Dimensions on page 65.]  
Shielded  
Model  
Size  
(Sensing  
distance)  
Connection  
method  
Body  
size  
Operation  
mode  
PNP  
NPN  
--- *2  
IO-Link (COM3)  
IO-Link (COM2) *2  
E2EQ-X1R5B1D8 2M  
E2EQ-X1R5B28 2M  
NO  
NC  
E2EQ-X1R5B1T8 2M  
-
E2EQ-X1R5C18 2M  
E2EQ-X1R5C28 2M  
Pre-wired (2 m) *1 38 mm  
M12 Pre-wired  
Smartclick  
Connector (0.3 m)  
NO  
NC  
E2EQ-X1R5B1T8-M1TJ 0.3M  
-
E2EQ-X1R5B1D8-M1TJ 0.3M  
E2EQ-X1R5B28-M1TJ 0.3M  
E2EQ-X1R5C18-M1TJ 0.3M  
E2EQ-X1R5C28-M1TJ 0.3M  
M8  
(1.5 mm)  
38 mm  
NO  
NC  
E2EQ-X1R5B1T8-M1  
E2EQ-X1R5B1D8-M1  
E2EQ-X1R5B28-M1  
E2EQ-X1R5C18-M1  
E2EQ-X1R5C28-M1  
E2EQ-X2C112 2M  
M12 Connector  
43 mm  
-
NO  
E2EQ-X2B1T12 2M  
E2EQ-X2B1D12 2M  
Pre-wired (2 m) *1 47 mm  
M12 Pre-wired  
NC  
-
E2EQ-X2B212 2M  
E2EQ-X2C212 2M  
NO+NC  
NO  
-
E2EQ-X2B3D12 2M  
E2EQ-X2C312 2M  
E2EQ-X2B1T12-M1TJ 0.3M  
E2EQ-X2B1D12-M1TJ 0.3M  
E2EQ-X2B212-M1TJ 0.3M  
E2EQ-X2B3D12-M1TJ 0.3M  
E2EQ-X2B1D12-M1  
E2EQ-X2C112-M1TJ 0.3M  
E2EQ-X2C212-M1TJ 0.3M  
E2EQ-X2C312-M1TJ 0.3M  
E2EQ-X2C112-M1  
M12  
(2 mm)  
Smartclick  
47 mm  
NC  
-
Connector (0.3 m)  
NO+NC  
NO  
-
E2EQ-X2B1T12-M1  
M12 Connector  
48 mm  
NC  
-
E2EQ-X2B212-M1  
E2EQ-X2C212-M1  
NO+NC  
NO  
-
E2EQ-X2B3D12-M1  
E2EQ-X2C312-M1  
E2EQ-X5B1T18 2M  
E2EQ-X5B1D18 2M  
E2EQ-X5C118 2M  
Pre-wired (2 m) *1 55 mm  
M12 Pre-wired  
NC  
-
E2EQ-X5B218 2M  
E2EQ-X5C218 2M  
NO+NC  
NO  
-
E2EQ-X5B3D18 2M  
E2EQ-X5C318 2M  
E2EQ-X5B1T18-M1TJ 0.3M  
E2EQ-X5B1D18-M1TJ 0.3M  
E2EQ-X5B218-M1TJ 0.3M  
E2EQ-X5B3D18-M1TJ 0.3M  
E2EQ-X5B1D18-M1  
E2EQ-X5C118-M1TJ 0.3M  
E2EQ-X5C218-M1TJ 0.3M  
E2EQ-X5C318-M1TJ 0.3M  
E2EQ-X5C118-M1  
M18  
(5 mm)  
Smartclick  
55 mm  
NC  
-
Connector (0.3 m)  
NO+NC  
NO  
-
E2EQ-X5B1T18-M1  
M12 Connector  
53 mm  
NC  
-
E2EQ-X5B218-M1  
E2EQ-X5C218-M1  
NO+NC  
NO  
-
E2EQ-X5B3D18-M1  
E2EQ-X5C318-M1  
E2EQ-X10B1T30 2M  
E2EQ-X10B1D30 2M  
E2EQ-X10B230 2M  
E2EQ-X10C130 2M  
E2EQ-X10C230 2M  
E2EQ-X10C330 2M  
E2EQ-X10C130-M1TJ 0.3M  
E2EQ-X10C230-M1TJ 0.3M  
E2EQ-X10C330-M1TJ 0.3M  
E2EQ-X10C130-M1  
E2EQ-X10C230-M1  
E2EQ-X10C330-M1  
Pre-wired (2 m) *1 60 mm  
M12 Pre-wired  
NC  
-
NO+NC  
NO  
-
E2EQ-X10B3D30 2M  
E2EQ-X10B1D30-M1TJ 0.3M  
E2EQ-X10B230-M1TJ 0.3M  
E2EQ-X10B3D30-M1TJ 0.3M  
E2EQ-X10B1D30-M1  
E2EQ-X10B230-M1  
E2EQ-X10B1T30-M1TJ 0.3M  
M30  
(10 mm)  
Smartclick  
60 mm  
NC  
-
Connector (0.3 m)  
NO+NC  
NO  
-
E2EQ-X10B1T30-M1  
M12 Connector  
58 mm  
NC  
-
-
NO+NC  
E2EQ-X10B3D30-M1  
*1. Models with 5-m cable length are also available (Example: E2EQ-X6B1D12 5M)  
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
Note: Operation mode NO can be changed to NC via IO-Link communications.  
34  
E2E/E2EQ NEXT Series  
Accessories (Sold Separately)  
Sensor I/O Connectors  
(Models for Pre-wired Connectors) A Sensor I/O Connector is not provided with the Sensor. It must be ordered separately  
as required.  
Round Oil-resistant Connectors XS5 NEXT series  
Cable  
diameter  
(mm)  
Cable  
specification  
Cable connection  
direction  
Cable  
length (m)  
Sensor I/O Connector  
model number  
Applicable Proximity  
Sensor model number  
Appearance  
Type  
1
2
XS5F-D421-C80-X  
XS5F-D421-D80-X  
XS5F-D421-E80-X  
XS5F-D421-G80-X  
XS5F-D421-J80-X  
XS5F-D421-C80-XR  
XS5F-D421-D80-XR  
XS5F-D421-E80-XR  
XS5F-D421-G80-XR  
XS5F-D421-J80-XR  
XS5W-D421-C81-X  
XS5W-D421-D81-X  
XS5W-D421-E81-X  
XS5W-D421-G81-X  
XS5W-D421-J81-X  
XS5W-D421-C81-XR  
XS5W-D421-D81-XR  
XS5W-D421-E81-XR  
XS5W-D421-G81-XR  
XS5W-D421-J81-XR  
Oil-resistant  
PVC cable  
Sockets on One  
Cable End  
6 dia.  
6 dia.  
6 dia.  
6 dia.  
Straight  
Straight  
3
5
10  
1
M12  
Smartclick  
Connector Models  
2
Oil-resistant  
PVC robot cable Cable End  
Sockets on One  
3
5
Straight type  
E2E-X@@@-M1TJ(R)  
E2EQ-X@@@-M1TJ  
E2E(Q)-X@@@-M1  
10  
1
2
Oil-resistant  
PVC cable  
Socket and Plug  
on Cable Ends  
Straight (Socket)/  
Straight (Plug)  
3
5
10  
1
2
Oil-resistant  
PVC robot cable on Cable Ends  
Socket and Plug  
Straight (Socket)/  
Straight (Plug)  
3
5
10  
Note: For details of the connector, refer to XS5 NEXT Series on page 87.  
Round Water-resistant Connectors XS5 series  
Cable  
diameter  
(mm)  
Cable  
length  
(m)  
Cable  
Specification  
Cable Connection  
Direction  
Sensor I/O Connector  
model number  
Applicable Proximity  
Sensor model number  
Appearance  
Type  
1
2
XS5F-D421-C80-F  
XS5F-D421-D80-F  
XS5F-D421-E80-F  
XS5F-D421-G80-F  
XS5F-D421-J80-F  
XS5F-D422-C80-F  
XS5F-D422-D80-F  
XS5F-D422-E80-F  
XS5F-D422-G80-F  
XS5F-D422-J80-F  
XS5W-D421-C81-F  
XS5W-D421-D81-F  
XS5W-D421-E81-F  
XS5W-D421-G81-F  
XS5W-D421-J81-F  
XS5W-D422-D81-F  
XS5W-D422-G81-F  
Straight  
3
5
10  
1
M12  
Smartclick  
Sockets on One  
Cable End  
6 dia.  
Connector  
2
Right-angle  
3
Straight type  
5
10  
1
E2E-X@@@-M1TJ(R)  
E2EQ-X@@@-M1TJ  
E2E(Q)-X@@@-M1  
PVC robot cable  
2
Straight (Socket)/  
Straight (Plug)  
3
5
Right-angle type  
10  
2
Socket and Plug  
on Cable Ends  
Right-angle (Socket)/  
Right-angle (Plug)  
6 dia.  
5
2
5
2
5
XS5W-D423-D81-F  
XS5W-D423-G81-F  
XS5W-D424-D81-F  
XS5W-D424-G81-F  
Straight (Socket)/  
Right-angle (Plug)  
Right-angle (Socket)/  
Straight (Plug)  
Note: For details of the connector, refer to XS5 Series on page 94.  
35  
E2E/E2EQ NEXT Series  
Round Water-resistant Connectors XS3W-M8/XS3F-M8 series  
Cable  
diameter cablecores  
(mm)  
No. of  
Cable  
length  
(m)  
Applicable  
ProximitySensor  
model number  
Cable  
specification  
Cable connection  
direction  
Sensor I/O Connector  
model number  
Appearance  
Type  
(Poles)  
2
5
XS3F-M8PVC3S2M  
XS3F-M8PVC3S5M  
XS3F-M8PVC3S10M  
XS3F-M8PVC3A2M  
XS3F-M8PVC3A5M  
XS3F-M8PVC3A10M  
XS3F-M8PVC4S2M  
XS3F-M8PVC4S5M  
XS3F-M8PVC4S10M  
XS3F-M8PVC4A2M  
XS3F-M8PVC4A5M  
XS3F-M8PVC4A10M  
XS3W-M8PVC3SS2M  
XS3W-M8PVC3SS5M  
XS3W-M8PVC3SS10M  
XS3W-M8PVC3SA2M  
XS3W-M8PVC3SA5M  
XS3W-M8PVC3SA10M  
XS3W-M8PVC4SS2M  
XS3W-M8PVC4SS5M  
XS3W-M8PVC4SS10M  
XS3W-M8PVC4SA2M  
XS3W-M8PVC4SA5M  
XS3W-M8PVC4SA10M  
Straight  
10  
2
3
E2E-X@@@-M5  
E2E-X@@@-M3  
E2E-X@@@-M5  
E2E-X@@@-M3  
Right-angle  
5
10  
2
Sockets on One  
Cable End  
M8 Connector  
Straight type  
5
Straight  
10  
2
4
3
4
Right-angle  
5
10  
2
PVC cable  
5 dia.  
Straight (Plug)/  
Straight (Socket)  
Right-angle type  
5
10  
2
Straight (Plug)/  
Right-angle (Socket)  
5
10  
2
Socket and Plug  
on Cable Ends  
Straight (Plug)/  
Straight (Socket)  
5
10  
2
Straight (Plug)/  
Right-angle (Socket)  
5
10  
Note: For details of the connector, refer to XS3W-M8/XS3F-M8 Series on page 102.  
Sensor I/O Connectors Oil resistance performance of mating combination  
E2E NEXT Series  
Applicable connector Model  
Connecting method  
Pre-wired Connector Models  
M12 Connector Models  
Model  
E2E-X@@-M1TJ(R)  
E2E-X@@-M1  
E2E-X@@-M3  
E2E-X@@-M5  
XS5 NEXT Series  
XS5 Series  
XS3W-M8/XS3F-M8 Series  
Oil resistant (2 years) *  
Water-resistant (IP67)  
---  
Water-resistant (IP67)  
Water-resistant (IP67)  
---  
M8 Connector (4-pin) Models  
M8 Connector (3-pin) Models  
---  
---  
---  
---  
Water-resistant (IP67)  
Water-resistant (IP67)  
* Applicable cutting oil type: specified in JIS K 2241:2000  
2 years of oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).  
Products to be shipped will have around 2 years of oil resistance, but will very depending on the product.  
e-jig (Mounting Sleeves) [Refer to Dimensions on page 66.]  
A Mounting Bracket is not provided with the Sensor. It must be ordered separately as required.  
Only applicable to standard body-sized E2E NEXT Series Sensors.  
Appearance  
Model  
Applicable Sensors  
E2E NEXT M8 Shielded Sensors  
Y92E-J8S12  
Y92E-J12S18  
Y92E-J18S30  
E2E NEXT M12 Shielded Sensors  
E2E NEXT M18 Shielded Sensors  
Note: Not applicable for E2E NEXT Series long-body models and E2EQ NEXT Series (spatter-resistant) models.  
36  
E2E/E2EQ NEXT Series  
Ratings and Specifications  
PREMIUM Model  
E2E NEXT Series (Quadruple/Triple distance model)  
DC 3-wire  
Shielded  
Types  
Size  
Quadruple distance model  
Triple distance model  
M8  
M12  
M18  
M30  
M8  
M12  
M18  
M30  
Item  
Model  
E2E-X4@8  
4 mm±10%  
0 to 3 mm  
E2E-X9@12  
9 mm±10%  
0 to 6.8 mm  
E2E-X14@18  
14 mm±10%  
0 to 10.6 mm  
E2E-X23@30  
23 mm±10%  
0 to 17.6 mm  
E2E-X3@8  
3 mm±10%  
0 to 2.4 mm  
E2E-X6@12  
6 mm±10%  
0 to 4.8 mm  
E2E-X12@18  
12 mm±10%  
0 to 9.6 mm  
E2E-X22@30  
22 mm±10%  
0 to 16.8 mm  
Sensing distance  
Setting distance  
Differential travel  
Detectable object  
15% max. of sensing distance  
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)  
Iron, Iron, Iron, Iron, Iron,  
12 × 12 × 1 mm 27 × 27 × 1 mm 42 × 42 × 1 mm 69 × 69 × 1 mm 9 × 9 × 1 mm  
Standard sensing  
object  
Iron,  
Iron,  
Iron,  
18 × 18 × 1 mm 36 × 36 × 1 mm 66 × 66 × 1 mm  
Response frequency  
*1  
700 Hz  
700 Hz  
350 Hz  
200 Hz  
1,000 Hz  
800 Hz 500 Hz 200 Hz  
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2  
1-output models: 16 mA max.,  
2-output models: 20 mA max.  
Current consumption 1-output models:16 mA max.  
Output configuration  
B@ Models: PNP open collector, C@ Models: NPN open collector  
1-output models (B1, C1): NO (Normally open),  
1-output models (B2, C2): NC (Normally closed),  
2-output models (B3, C3): NO+NC (Normally open,  
Normally closed)  
Operation mode  
(with sensing object  
approaching)  
1-output models (B1, C1): NO (Normally open),  
1-output models (B2, C2): NC (Normally closed)  
1-outputmodels: 1-output models:  
Load  
1-output models:  
10 to 30 VDC,  
10 to 30 VDC, Class 2, 100 mA max.,  
current  
10 to 30 VDC, Class 2, 50 mA max.  
Class 2, 100 mA 2-output models:  
max.  
10 to 30 VDC, Class 2, 50 mA max.  
Control  
output  
1-outputmodels:  
2 V max.  
(Load current:  
100 mA, Cable  
length: 2 m)  
1-output models:  
2 V max. (Load current: 100 mA, Cable length: 2 m),  
2-output models:  
Residual  
voltage  
1-output models:  
2 V max. (Load current: 50 mA, Cable length: 2 m)  
2 V max. (Load current: 50 mA, Cable length: 2 m)  
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)  
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)  
Indicator *2  
Protection circuits  
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection  
Operating:  
-25 to 60°C  
Ambient temperature Storage:  
Operating/Storage: -25 to 70°C (with no icing or condensation)  
range  
-25 to 70°C  
(with no icing or  
condensation)  
Ambient humidity  
range  
Operating/Storage: 35% to 95% (with no condensation)  
-15% to 25%  
max. of  
sensing  
Temperature  
influence  
distance at  
23°C in the  
temperature  
range of -25 to  
60°C  
±15% max. of sensing distance at 23°C in the  
temperature range of -25 to 70°C  
±10% max. of sensing distance at 23°C in the temperature range of  
-25 to 70°C  
Voltage influence  
Insulation resistance  
Dielectric strength  
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
Vibration resistance  
(destruction)  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
500 m/s2 10  
times each in  
X, Y, and Z  
directions  
500 m/s2 10  
times each in  
X, Y, and Z  
directions  
Shock resistance  
(destruction)  
1,000 m/s2 10 times each in X, Y, and Z directions  
1,000 m/s2 10 times each in X, Y, and Z directions  
Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex  
1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature:  
35°C max.)  
Degree of protection  
Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K  
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12  
Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)  
Connection method  
Pre-wired  
Approx. 85 g  
Approx. 95 g  
Approx. 180 g Approx. 260 g Approx. 85 g  
Approx. 95 g  
Approx. 180 g Approx. 260 g  
M12  
Weight*4  
Pre-wired  
(packed  
Approx. 55 g  
Approx. 70 g  
Approx. 115 g Approx. 200 g Approx. 55 g  
Approx. 70 g  
Approx. 115 g Approx. 200 g  
Smartclick  
state)  
Connector  
Connector Approx. 40 g *5 Approx. 55 g  
Approx. 95 g  
Approx. 180 g Approx. 40 g *5 Approx. 55 g  
Approx. 95 g  
Approx. 180 g  
37  
E2E/E2EQ NEXT Series  
Types  
Size  
Quadruple distance model  
Triple distance model  
M8  
M12  
M18  
M30  
M8  
M12  
M18  
M30  
Item  
Model  
E2E-X4@8  
E2E-X9@12  
E2E-X14@18  
E2E-X23@30  
E2E-X3@8  
E2E-X6@12  
E2E-X12@18  
E2E-X22@30  
Case  
Nickel-plated brass  
Sensing  
surface  
Polybutylene terephthalat (PBT)  
Nickel-plated brass  
Clamping  
nuts  
Materials  
Toothed  
washers  
Zinc-plated iron  
Cable  
Vinyl chloride (PVC)  
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of  
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating  
hours read-out, readout of the sensor internal temperature, and initial reset  
Main IO-Link  
functions*2  
IO-Link  
specificati Ver 1.1  
on  
IO-Link  
Commun  
ication  
specifica  
tions *2  
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)  
Data  
length  
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)  
Minimum  
cycle time  
COM2: 2.3 ms, COM3: 0.4 ms  
Accessories  
Instruction manual, Clamping nuts, Toothed washer  
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard  
sensing object, and a set distance of half the sensing distance.  
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
*3. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards.  
2-year oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).  
The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round Oil-resistant Connectors XS5 NEXT series correctly.  
The degree of protection is not satisfied with the part where cable wires are uncovered for the Pre-wired Models.  
*4. Weight of the standard body-sized model.  
*5. Both M8 connectors and M12 connectors are available.  
38  
E2E/E2EQ NEXT Series  
PREMIUM Model  
E2E NEXT Series (Quadruple/Triple distance model)  
DC 3-wire  
Unshielded  
Types  
Size  
Quadruple distance model  
M12 M18  
E2E-X16M@12 E2E-X30M@18 E2E-X50M@30  
Triple distance model  
M8  
M30  
M8  
M12  
M18  
M30  
Item  
Model E2E-X8M@8  
E2E-X6M@8  
6 mm±10%  
0 to 4.8 mm  
E2E-X10M@12 E2E-X20M@18 E2E-X40M@30  
Sensing distance  
Setting distance  
Differential travel  
Detectable object  
8 mm±10%  
0 to 6 mm  
16 mm±10%  
0 to 12.2 mm  
30 mm±10%  
0 to 23 mm  
50 mm±10%  
0 to 38.2 mm  
10 mm±10%  
0 to 8 mm  
20 mm±10%  
0 to 16 mm  
40 mm±10%  
0 to 32 mm  
15% max. of sensing distance  
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)  
Iron, Iron, Iron, Iron, Iron,  
Standard sensing  
object  
Iron,  
Iron,  
Iron,  
24 × 24 × 1 mm 48 × 48 × 1 mm 90 × 90 × 1 mm 150 × 150 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm 60 × 60 × 1 mm 120 × 120 × 1 mm  
Response frequency  
*1  
500 Hz 400 Hz 200 Hz 100 Hz 800 Hz 400 Hz 200 Hz 100 Hz  
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2  
1-output models: 16 mA max.,  
2-output models: 20 mA max.  
Current consumption 1-output models: 16 mA max.  
B@ Models: PNP open collector  
Output configuration  
C@ Models: NPN open collector  
1-output models (B1, C1): NO (Normally open),  
1-output models (B2, C2): NC (Normally closed),  
2-output models (B3, C3):  
Operation mode  
1-output models (B1, C1): NO (Normally open),  
(with sensing object  
1-output models (B2, C2): NC (Normally closed)  
approaching)  
NO+NC (Normally open, Normally closed)  
1-outputmodels: 1-output models:  
Load  
1-output models:  
10 to 30 VDC,  
10 to 30 VDC, Class 2, 100 mA max.,  
current  
10 to 30 VDC, Class 2, 50 mA max.  
Class 2, 100 mA 2-output models:  
max.  
10 to 30 VDC, Class 2, 50 mA max.  
Control  
output  
1-outputmodels:  
2 V max.  
(Load current:  
100 mA, Cable  
length: 2 m)  
1-output models:  
2 V max. (Load current: 100 mA, Cable length: 2 m),  
2-output models:  
Residual  
voltage  
1-output models:  
2 V max. (Load current: 50 mA, Cable length: 2 m)  
2 V max. (Load current: 50 mA, Cable length: 2 m)  
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)  
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)  
Indicator *2  
Protection circuits  
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection  
Ambient temperature  
range  
Operating/Storage: -25 to 70°C (with no icing or condensation)  
Ambient humidity  
range  
Operating/Storage: 35% to 95% (with no condensation)  
Temperature  
influence  
±15% max. of sensing distance at 23°C in the temperature range of ±10% max. of sensing distance at 23°C in the temperature range of  
-25 to 70°C  
-25 to 70°C  
Voltage influence  
Insulation resistance  
Dielectric strength  
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
Vibration resistance  
(destruction)  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
500 m/s2 10  
times each in  
X, Y, and Z  
directions  
500 m/s2 10  
times each in  
X, Y, and Z  
directions  
Shock resistance  
(destruction)  
1,000 m/s2 10 times each in X, Y, and Z directions  
1,000 m/s2 10 times each in X, Y, and Z directions  
Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex  
1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature:  
35°C max.)  
Degree of protection  
Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K  
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12  
Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)  
Connection method  
Pre-wired  
Approx. 85 g  
Approx. 95 g  
Approx. 190 g Approx. 310 g Approx. 85 g  
Approx. 95 g  
Approx. 190 g Approx. 280 g  
Approx. 125 g Approx. 220 g  
Approx. 105 g Approx. 200 g  
M12  
Weight*4  
Pre-wired  
(packed  
Approx. 55 g  
Approx. 70 g  
Approx. 125 g Approx. 250 g Approx. 55 g  
Approx. 70 g  
Smartclick  
state)  
Connector  
Connector Approx. 40 g *5 Approx. 55 g  
Approx. 105 g Approx. 230 g Approx. 40 g *5 Approx. 55 g  
39  
E2E/E2EQ NEXT Series  
Types  
Size  
Quadruple distance model  
M12 M18  
Triple distance model  
M12 M18  
M8  
M30  
M8  
M30  
Item  
Model E2E-X8M@8  
E2E-X16M@12 E2E-X30M@18 E2E-X50M@30  
E2E-X6M@8  
E2E-X10M@12 E2E-X20M@18 E2E-X40M@30  
Stainless  
(SUS303)  
Stainless  
(SUS303)  
Case  
Nickel-plated brass  
Nickel-plated brass  
Sensing  
surface  
Polybutylene terephthalat (PBT)  
Materials Clamping  
nuts  
Nickel-plated brass  
Toothed  
washers  
Zinc-plated iron  
Cable  
Vinyl chloride (PVC)  
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of  
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating  
hours read-out, readout of the sensor internal temperature, and initial reset  
Main IO-Link  
functions*2  
IO-Link  
specificati Ver1.1  
on  
IO-Link  
Commun  
ication  
specifica  
tions *2  
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)  
Data  
length  
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)  
Minimum  
cycle time  
COM2: 2.3 ms, COM3: 0.4 ms  
Accessories  
Instruction manual, Clamping nuts, Toothed washer  
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard  
sensing object, and a set distance of half the sensing distance.  
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
*3. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards. 2-year oil resistance indicates the  
median value of the product design and the oil-resistance performance criterion result (=Typical value). Actual performance can be expected  
to decline after two years on average from shipment. The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round  
Oil-resistant Connectors XS5 NEXT series correctly. The degree of protection is not satisfied with the part where cable wires are uncovered  
for the Pre-wired Models.  
*4. Weight of the standard body-sized model.  
*5. Both M8 connectors and M12 connectors are available.  
40  
E2E/E2EQ NEXT Series  
PREMIUM Model  
E2EQ NEXT Series (Spatter-resistant Triple distance model)  
DC 3-wire  
Shielded  
Types  
Triple distance Models  
Size  
M8  
M12  
E2EQ-X6@12  
6 mm±10%  
0 to 4.8 mm  
M18  
E2EQ-X12@18  
12 mm±10%  
0 to 9.6 mm  
M30  
Item  
Model  
E2EQ-X3@8  
E2EQ-X22@30  
Sensing distance  
Setting distance  
Differential travel  
Detectable object  
3 mm±10%  
22 mm±10%  
0 to 2.4 mm  
0 to 16.8 mm  
15% max. of sensing distance  
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)  
Standard sensing object  
Response frequency *1  
Power supply voltage  
Iron, 9 × 9 × 1 mm  
1,000 Hz  
Iron, 18 × 18 × 1 mm  
800 Hz  
Iron, 36 × 36 × 1 mm  
500 Hz  
Iron, 66 × 66 × 1 mm  
200 Hz  
10 to 30 VDC (including 10% ripple (p-p)), Class 2  
1-output models: 16 mA max.  
2-output models: 20 mA max.  
Current consumption  
Output configuration  
1-output models: 16 mA max.  
B@ Models: PNP open collector, C@ Models: NPN open collector  
1-output models (B1, C1): NO  
(Normally open),  
1-output models (B2, C2): NC  
(Normally closed)  
Operation mode  
(with sensing object  
approaching)  
1-output models (B1, C1): NO (Normally open),  
1-output models (B2, C2): NC (Normally closed),  
2-output models (B3, C3): NO+NC (Normally open, Normally closed)  
1-output models: 10 to 30 VDC, 1-output models: 10 to 30 VDC, Class 2, 100 mA max.,,  
Load current  
Control  
Class 2, 100 mA max.  
2-output models: 10 to 30 VDC, Class 2, 50 mA max.  
1-output models: 2 V max.  
(Load current: 100 mA,  
Cable length: 2 m)  
output  
Residual  
voltage  
1-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m),  
2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m)  
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)  
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s  
intervals)  
Indicator *2  
Protection circuits  
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection  
Ambient temperature range Operating/Storage: -25 to 70°C (with no icing or condensation)  
Ambient humidity range  
Temperature influence  
Voltage influence  
Operating/Storage: 35% to 95% (with no condensation)  
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C  
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
Insulation resistance  
Dielectric strength  
Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
500 m/s2 10 times each in X, Y,  
and Z directions  
Shock resistance (destruction)  
1,000 m/s2 10 times each in X, Y, and Z directions  
Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, JIS C 0920 Annex 1: IP67G  
Connector Models: IEC 60529: IP67  
Degree of protection  
Connection method  
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m), M12 Connector Models  
Pre-wired  
Models  
Approx. 85 g  
Approx. 95 g  
Approx. 180 g  
Approx. 260 g  
Weight *3  
M12 Pre-wired  
(packed  
Smartclick  
state)  
Approx. 55 g  
Approx. 40 g  
Approx. 70 g  
Approx. 55 g  
Approx. 115 g  
Approx. 95 g  
Approx. 200 g  
Approx. 180 g  
Connector  
Connector  
Case  
Fluororesin coating (Base material: brass)  
Sensing surface Fluorine resin  
Clamping nuts Fluororesin coating (Base material: brass)  
Materials  
Toothed  
Zinc-plated iron  
washers  
Cable  
Vinyl chloride (PVC)  
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer  
function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor  
output, operating hours read-out, readout of the sensor internal temperature, and initial reset  
Main IO-Link functions *2  
IO-Link  
Ver 1.1  
specification  
IO-Link  
Communic  
ation  
specificati  
ons *2  
Baud rate  
COM2 (38.4 kbps), COM3 (230.4 kbps)  
Data length  
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)  
Minimum cycle  
time  
COM2: 2.3 ms, COM3: 0.4 ms  
Accessories  
Instruction manual, Clamping nuts, Toothed washer  
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard  
sensing object, and a set distance of half the sensing distance.  
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
*3. Weight of the standard body-sized model.  
41  
E2E/E2EQ NEXT Series  
BASIC Model  
E2E NEXT Series (Double/Single distance model)  
DC 3-wire  
Shielded  
Types  
Size  
Double distance  
Single distance  
M8  
M12  
M18  
M30  
M8  
M12  
M18  
M30  
Item  
Model  
E2E-X2@8  
E2E-X4@12  
4 mm±10%  
0 to 3.2 mm  
E2E-X8@18  
8 mm±10%  
0 to 6.4 mm  
E2E-X15@30  
15 mm±10%  
0 to 12 mm  
E2E-X1R5@8  
1.5 mm±10%  
0 to 1.2 mm  
E2E-X2@12  
2 mm±10%  
0 to 1.6 mm  
E2E-X5@18  
5 mm±10%  
0 to 4 mm  
E2E-X10@30  
10 mm±10%  
0 to 8 mm  
Sensing distance  
Setting distance  
Differential travel  
Detectable object  
2 mm±10%  
0 to 1.6 mm  
15% max. of sensing distance  
10% max. of sensing distance  
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)  
Standard sensing  
object  
Iron,  
8 × 8 × 1 mm  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
12 × 12 × 1 mm 24 × 24 × 1 mm 45 × 45 × 1 mm 8 × 8 × 1 mm  
12 × 12 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm  
Response frequency  
*1  
1,500 Hz  
1,000 Hz  
500 Hz  
250 Hz  
2,000 Hz  
1,500 Hz  
600 Hz  
400 Hz  
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2  
1-output models: 16 mA max.  
Current consumption  
2-output models: 20 mA max.  
B@ Models: PNP open collector  
Output configuration  
C@ Models: NPN open collector  
Operation mode  
(with sensing object  
approaching)  
1-output models (B1, C1): NO (Normally open),  
1-output models (B2, C2): NC (Normally closed),  
2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3  
1-output models:  
10 to 30 VDC,  
Class 2, 200 mA  
max., (-40 to  
1-output models:  
10 to 30 VDC,  
Class 2, 200 mA  
max., (-40 to  
1-output models:  
10 to 30 VDC, Class 2, 200 mA max.,  
1-output models:  
10 to 30 VDC, Class 2, 200 mA max.,  
Load  
70°C), 100 mA  
70°C), 100 mA  
current  
max., (70 to 85°C) 2-output models:  
2-output models: 10 to 30 VDC, Class 2, 100 mA max.  
max., (70 to 85°C) 2-output models:  
2-output models: 10 to 30 VDC, Class 2, 100 mA max.  
10 to 30 VDC,  
Class 2, 50 mA  
max.  
10 to 30 VDC,  
Class 2, 50 mA  
max.  
Control  
output  
1-output models:  
2 V max. (Load  
current: 200 mA,  
1-output models:  
2 V max. (Load  
1-output models:  
1-output models:  
2 V max. (Load current: 200 mA, Cable length: 2  
2 V max. (Load current: 200 mA, Cable length: 2 current: 200 mA,  
Residual  
voltage  
Cablelength:2m), m),  
2-output models: 2-output models:  
Cablelength:2m), m),  
2-output models: 2-output models:  
2 V max. (Load current: 100 mA, Cable length: 2  
m)  
2 V max. (Load  
current: 50 mA,  
Cable length: 2 m)  
2 V max. (Load current: 100 mA, Cable length: 2 2 V max. (Load  
m)  
current: 50 mA,  
Cable length: 2 m)  
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)  
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)  
Indicator *2  
Protection circuits  
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection  
Ambient temperature Operating/Storage: -40 to 85°C (with no icing or condensation)  
range  
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C.  
Ambient humidity  
range  
Operating/Storage: 35% to 95% (with no condensation)  
Temperature  
influence  
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C  
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C  
Voltage influence  
Insulation resistance  
Dielectric strength  
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
Vibration resistance  
(destruction)  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
500 m/s2 10 times  
each in X, Y, and  
Z directions  
500 m/s2 10 times  
each in X, Y, and  
Z directions  
Shock resistance  
(destruction)  
1,000 m/s2 10 times each in X, Y, and Z  
directions  
1,000 m/s2 10 times each in X, Y, and Z  
directions  
Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex  
1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature:  
35°C max.)  
Degree of protection  
Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K  
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector  
Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)  
Connection method  
Pre-wired  
Approx. 85 g  
Approx. 95 g  
Approx. 70 g  
Approx. 55 g  
Approx. 170 g Approx. 240 g Approx. 85 g  
Approx. 95 g  
Approx. 70 g  
Approx. 55 g  
Approx. 170 g Approx. 240 g  
M12  
Weight *5  
Pre-wired  
(packed  
Approx. 55 g  
Approx. 105 g Approx. 170 g Approx. 55 g  
Approx. 105 g Approx. 170 g  
Smartclick  
state)  
Connector  
Connector Approx. 40 g *6  
Approx. 85 g  
Approx. 160 g Approx. 40 g *6  
Approx. 85 g  
Approx. 160 g  
42  
E2E/E2EQ NEXT Series  
Types  
Size  
Double distance  
Single distance  
M8  
M12  
M18  
E2E-X8@18  
M30  
M8  
M12  
M18  
M30  
Item  
Model  
E2E-X2@8  
E2E-X4@12  
E2E-X15@30  
E2E-X1R5@8  
E2E-X2@12  
E2E-X5@18  
E2E-X10@30  
Stainless  
(SUS303)  
Stainless  
(SUS303)  
Case  
Nickel-plated brass  
Nickel-plated brass  
Sensing  
surface  
Polybutylene terephthalat (PBT)  
Nickel-plated brass  
Materials Clamping  
nuts  
Toothed  
washers  
Zinc-plated iron  
Cable  
Vinyl chloride (PVC)  
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of  
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating  
hours read-out, readout of the sensor internal temperature, and initial reset  
Main IO-Link  
functions *2  
IO-Link  
specification  
Ver1.1  
IO-Link  
Commun  
ication  
specifica  
tions *2  
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)  
Data  
length  
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)  
Minimum  
cycle time  
COM2: 2.3 ms, COM3: 0.4 ms  
Accessories  
Instruction manual, Clamping nuts, Toothed washer  
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard  
sensing object, and a set distance of half the sensing distance.  
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
*3. Dual-output specification for the M8-size models is only applicable to long-size M12 Connector models.  
*4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards. 2-year oil resistance indicates the  
median value of the product design and the oil-resistance performance criterion result (=Typical value). Actual performance can be expected  
to decline after two years on average from shipment. The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round  
Oil-resistant Connectors XS5 NEXT series correctly. The degree of protection is not satisfied with the part where cable wires are uncovered  
for the Pre-wired Models.  
*5. Weight of the standard body-sized model.  
*6. Both M8 connectors and M12 connectors are available.  
43  
E2E/E2EQ NEXT Series  
BASIC Model  
E2E NEXT Series (Double/Single distance model)  
DC 3-wire  
Unshielded  
Types  
Size  
Double distance model  
M12 M18  
E2E-X8M@12 E2E-X16M  
Single distance model  
M12 M18  
E2E-X5M@12 E2E-X10M  
M8  
E2E-X4M@8  
4 mm±10%  
0 to 3.2 mm  
M30  
M8  
E2E-X2M@8  
2 mm±10%  
0 to 1.6 mm  
M30  
Item  
Model  
@
18 E2E-X30M  
@30  
@
18 E2E-X18M@30  
Sensing distance  
Setting distance  
Differential travel  
Detectable object  
8 mm±10%  
0 to 6.4 mm  
16 mm±10%  
30 mm±10%  
5 mm±10%  
0 to 4 mm  
10 mm±10%  
18 mm±10%  
0 to 14.4 mm  
0 to 12.8 mm 0 to 24 mm  
0 to 8 mm  
15% max. of sensing distance  
10% max. of sensing distance  
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)  
Standard sensing  
object  
Iron,  
12 × 12 × 1 mm  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
24 × 24 × 1 mm 48 × 48 × 1 mm 90 × 90 × 1 mm 8 × 8 × 1 mm  
15 × 15 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm  
Response frequency  
*1  
1,000 Hz  
800 Hz  
400 Hz  
100 Hz  
1,000 Hz  
800 Hz  
400 Hz  
100 Hz  
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2  
1-output models: 16 mA max.  
Current consumption  
2-output models: 20 mA max.  
B@ Models: PNP open collector  
Output configuration  
C@ Models: NPN open collector  
Operation mode  
(with sensing object  
approaching)  
1-output models (B1, C1): NO (Normally open),  
1-output models (B2, C3): NC (Normally closed)  
2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3  
1-output models:  
10 to 30 VDC,  
Class 2, 200 mA  
max., (-40 to  
1-output models:  
10 to 30 VDC,  
Class 2, 200 mA  
max., (-40 to  
1-output models:  
10 to 30 VDC, Class 2, 200 mA max.,  
1-output models:  
10 to 30 VDC, Class 2, 200 mA max.,  
Load  
70°C), 100 mA  
70°C), 100 mA  
current  
max., (70 to 85°C) 2-output models:  
2-output models: 10 to 30 VDC, Class 2, 100 mA max.  
max., (70 to 85°C) 2-output models:  
2-output models: 10 to 30 VDC, Class 2, 100 mA max.  
10 to 30 VDC,  
Class 2, 50 mA  
max.  
10 to 30 VDC,  
Class 2, 50 mA  
max.  
Control  
output  
1-output models:  
2 V max. (Load  
current: 200 mA,  
1-output models:  
2 V max. (Load  
1-output models:  
1-output models:  
2 V max. (under load current of 200 mA with  
2 V max. (Load current: 200 mA, Cable length: 2 current: 200 mA,  
Residual  
voltage  
Cablelength:2m), m),  
2-output models: 2-output models:  
Cablelength:2m), cable length of 2 m),  
2-output models: 2-output models:  
2 V max. (under load current of 100 mA with  
cable length of 2 m)  
2 V max. (Load  
current: 50 mA,  
Cable length: 2 m)  
2 V max. (Load current: 100 mA, Cable length: 2 2 V max. (Load  
m)  
current: 50 mA,  
Cable length: 2 m)  
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)  
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)  
Indicator *2  
Protection circuits  
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection  
Ambient temperature Operating/Storage: -40 to 85°C (with no icing or condensation)  
range  
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C.  
Ambient humidity  
range  
Operating/Storage: 35% to 95% (with no condensation)  
Temperature  
influence  
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C  
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C  
Voltage influence  
Insulation resistance  
Dielectric strength  
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
Vibration resistance  
(destruction)  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
500 m/s2 10 times  
each in X, Y, and  
Z directions  
500 m/s2 10 times  
each in X, Y, and  
Z directions  
Shock resistance  
(destruction)  
1,000 m/s2 10 times each in X, Y, and Z  
directions  
1,000 m/s2 10 times each in X, Y, and Z  
directions  
Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex  
1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature:  
35°C max.)  
Degree of protection  
Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K  
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Models (M12 Connector,  
M8 (4-pin) Connector and M8 (3-pin) Connector)  
Connection method  
Pre-wired  
Approx. 85 g  
Approx. 95 g  
Approx. 70 g  
Approx. 55 g  
Approx. 170 g Approx. 280 g Approx. 85 g  
Approx. 95 g  
Approx. 70 g  
Approx. 55 g  
Approx. 170 g Approx. 240 g  
M12  
Weight *5  
Pre-wired  
(packed  
Approx. 55 g  
Approx. 105 g Approx. 220 g Approx. 55 g  
Approx. 105 g Approx. 170 g  
Smartclick  
state)  
Connector  
Connector Approx. 40 g *6  
Approx. 85 g  
Approx. 200 g Approx. 40 g *6  
Approx. 85 g  
Approx. 160 g  
44  
E2E/E2EQ NEXT Series  
Types  
Size  
Double distance model  
M12 M18  
Single distance model  
M8  
M30  
M8  
M12  
M18  
M30  
Item  
Model  
E2E-X4M@8  
E2E-X8M@12 E2E-X16M@18 E2E-X30M@30  
E2E-X2M@8  
E2E-X5M@12 E2E-X10M@18 E2E-X18M@30  
Stainless  
(SUS303)  
Stainless  
(SUS303)  
Case  
Nickel-plated brass  
Nickel-plated brass  
Sensing  
surface  
Polybutylene terephthalat (PBT)  
Nickel-plated brass  
Materials Clamping  
nuts  
Toothed  
washers  
Zinc-plated iron  
Cable  
Vinyl chloride (PVC)  
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of  
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating  
hours read-out, readout of the sensor internal temperature, and initial reset  
Main IO-Link  
functions *2  
IO-Link  
specificati Ver 1.1  
on  
IO-Link  
Commun  
ication  
specifica  
tions *2  
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)  
Data  
length  
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)  
Minimum  
cycle time  
COM2: 2.3 ms, COM3: 0.4 ms  
Accessories  
Instruction manual, Clamping nuts, Toothed washer  
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard  
sensing object, and a set distance of half the sensing distance.  
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
*3. Dual-output specification for the M8-size models is only applicable to long-size M12 Connector models.  
*4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards. 2-year oil resistance indicates the  
median value of the product design and the oil-resistance performance criterion result (=Typical value). Actual performance can be expected  
to decline after two years on average from shipment. The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round  
Oil-resistant Connectors XS5 NEXT series correctly. The degree of protection is not satisfied with the part where cable wires are uncovered  
for the Pre-wired Models.  
*5. Weight of the standard body-sized model.  
*6. Both M8 connectors and M12 connectors are available.  
45  
E2E/E2EQ NEXT Series  
BASIC Model  
E2E Q NEXT Series (Spatter-resistant Double distance/Single distance model)  
DC 3-Wire Models  
Shielded  
Types  
Size  
Double distance  
M12 M18  
E2EQ-X4@12 E2EQ-X8@18 E2EQ-X15  
Single distance  
M12 M18  
E2EQ-X2@12 E2EQ-X5@18 E2EQ-X10  
M8  
E2EQ-X2@8  
2 mm±10%  
0 to 1.6 mm  
M30  
M8  
M30  
Item  
Model  
@
30  
15 mm±10%  
0 to 12 mm  
E2EQ-X1R5@8  
1.5 mm±10%  
0 to 1.2 mm  
@30  
Sensing distance  
Setting distance  
Differential travel  
Detectable object  
4 mm±10%  
0 to 3.2 mm  
8 mm±10%  
0 to 6.4 mm  
2 mm±10%  
0 to 1.6 mm  
5 mm±10%  
0 to 4 mm  
10 mm±10%  
0 to 8 mm  
15% max. of sensing distance  
10% max. of sensing distance  
Ferrous metals (For non-ferrous metals, refer to the Engineering Data on page 48.)  
Standard sensing  
object  
Iron,  
8 × 8 × 1 mm  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
12 × 12 × 1 mm 24 × 24 × 1 mm 45 × 45 × 1 mm 8 × 8 × 1 mm  
12 × 12 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm  
Response frequency  
*1  
1,500 Hz  
1,000 Hz  
500 Hz  
250 Hz  
2,000 Hz  
1,500 Hz  
600 Hz  
400 Hz  
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p)), Class 2  
1-output models: 16 mA max.  
Current consumption  
2-output models: 20 mA max.  
B@ Models: PNP open collector,  
Output configuration  
C@ Models: NPN open collector  
Operation mode  
(with sensing object  
approaching)  
1-output models (B1, C1): NO (Normally open),  
1-output models (B2, C2): NC (Normally closed)  
2-output models (B3, C3): NO+NC (Normally open, Normally closed)  
1-output models:  
10 to 30 VDC,  
Class 2, 200 mA  
1-output models:  
10 to 30 VDC,  
Class 2, 200 mA  
max., (-40 to  
max., (-40 to  
1-output models:  
1-output models:  
10 to 30 VDC, Class 2, 200 mA max.,  
Load  
70°C), 100 mA  
10 to 30 VDC, Class 2, 200 mA max.,  
70°C), 100 mA  
current  
max., (70 to 85°C) 2-output models:  
2-output models: 10 to 30 VDC, Class 2, 100 mA max.  
max., (70 to 85°C) 2-output models:  
2-output models: 10 to 30 VDC, Class 2, 100 mA max.  
10 to 30 VDC,  
Class 2, 50 mA  
max.  
10 to 30 VDC,  
Class 2, 50 mA  
max.  
Control  
output  
1-output models:  
2 V max. (Load  
current: 200 mA,  
1-output models:  
2 V max. (Load  
1-output models:  
1-output models:  
2 V max. (Load current: 200 mA, Cable length: 2  
2 V max. (Load current: 200 mA, Cable length: 2 current: 200 mA,  
Residual  
voltage  
Cablelength:2m), m),  
2-output models: 2-output models:  
Cablelength:2m), m),  
2-output models: 2-output models:  
2 V max. (Load current: 100 mA, Cable length: 2  
m)  
2 V max. (Load  
current: 50 mA,  
Cable length: 2 m)  
2 V max. (Load current: 100 mA, Cable length: 2 2 V max. (Load  
m)  
current: 50 mA,  
Cable length: 2 m)  
In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)  
In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals)  
Indicator *2  
Protection circuits  
Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection  
Ambient temperature Operating/Storage: -40 to 85°C (with no icing or condensation)  
range  
Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C.  
Ambient humidity  
range  
Operating/Storage: 35% to 95% (with no condensation)  
Temperature  
influence  
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C  
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C  
Voltage influence  
Insulation resistance  
Dielectric strength  
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
Vibration resistance  
(destruction)  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
500 m/s2 10 times  
each in X, Y, and  
Z directions  
500 m/s2 10 times  
each in X, Y, and  
Z directions  
Shock resistance  
(destruction)  
1,000 m/s2 10 times each in X, Y, and Z  
directions  
1,000 m/s2 10 times each in X, Y, and Z  
directions  
Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, JIS C 0920 Annex 1: IP67G  
Connector Models: IEC 60529 IP67  
Degree of protection  
Connection method  
Pre-wired  
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m), M12 Connector Models  
Approx. 85 g  
Approx. 55 g  
Approx. 95 g  
Approx. 70 g  
Approx. 55 g  
Approx. 170 g Approx. 240 g Approx. 85 g  
Approx. 105 g Approx. 170 g Approx. 55 g  
Approx. 95 g  
Approx. 70 g  
Approx. 55 g  
Approx. 170 g Approx. 240 g  
M12  
Weight *3  
Pre-wired  
(packed  
Approx. 105 g Approx. 170 g  
Smartclick  
state)  
Connector  
Connector Approx. 40 g  
Approx. 85 g  
Approx. 160 g Approx. 40 g  
Approx. 85 g  
Approx. 160 g  
46  
E2E/E2EQ NEXT Series  
Types  
Size  
Double distance  
M12 M18  
Single distance  
M8  
M30  
M8  
M12  
M18  
M30  
Item  
Model  
E2EQ-X2@8  
E2EQ-X4@12 E2EQ-X8@18 E2EQ-X15  
@30  
E2EQ-X1R5@8  
E2EQ-X2@12 E2EQ-X5@18 E2EQ-X10@30  
Fluororesin coating  
(Base material:  
SUS303)  
Fluororesin coating  
(Base material:  
SUS303)  
Case  
Fluororesin coating (Base material: brass)  
Fluororesin coating (Base material: brass)  
Sensing  
surface  
Fluorine resin  
Materials  
Clamping  
nuts  
Fluororesin coating (Base material: brass)  
Toothed  
washers  
Zinc-plated iron  
Cable  
Vinyl chloride (PVC)  
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of  
the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating  
hours read-out, readout of the sensor internal temperature, and initial reset  
Main IO-Link  
functions *2  
IO-Link  
specificati Ver1.1  
on  
IO-Link  
Commun  
ication  
specifica  
tions *2  
Baud rate COM2 (38.4 kbps), COM3 (230.4 kbps)  
Data  
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)  
length  
Minimum  
cycle time  
COM2: 2.3 ms, COM3: 0.4 ms  
Accessories  
Instruction manual, Clamping nuts, Toothed washer  
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard  
sensing object, and a set distance of half the sensing distance.  
*2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs.  
*3. Weight of the standard body-sized model.  
47  
E2E/E2EQ NEXT Series  
Engineering Data (Reference Value)  
Sensing Area  
PREMIUM Model  
Quadruple distance model  
Triple distance model, Spatter-resistant Triple distance model  
Shielded  
Shielded  
30  
30  
Y
E2E-X23@30  
E2E(Q)-X22@30  
X
25  
Y
25  
X
20  
20  
E2E-X14@18  
E2E(Q)-X12@18  
15  
15  
E2E(Q)-X6@12  
E2E-X9@12  
10  
10  
E2E-X4@8  
E2E(Q)-X3@8  
5
0
5
0
-15  
-10  
-5  
0
5
10  
15  
-15  
-10  
-5  
0
5
10  
15  
Distance Y (mm)  
Distance Y (mm)  
Unshielded  
Unshielded  
45  
40  
50  
45  
E2E-X40M@30  
E2E-X50M@30  
E2E-X30M@18  
Y
40  
35  
Y
X
35  
X
30  
E2E-X20M@18  
30  
25  
20  
15  
10  
25  
20  
15  
10  
5
E2E-X16M@12  
E2E-X10M@12  
E2E-X6M@8  
E2E-X8M@8  
5
0
0
-40 -30 -20 -10  
0
10 20 30 40  
Distance Y (mm)  
-30  
-20  
-10  
0
10  
20  
30  
Distance Y (mm)  
BASIC Model  
Double distance model, Spatter-resistant Double distance model  
Shielded  
Single distance model, Spatter-resistant Single distance model  
Shielded  
16  
Y
12  
Y
X
E2E(Q)-X10@30  
X
14  
10  
8
E2E(Q)-X15@30  
12  
10  
8
E2E(Q)-X8@18  
E2E(Q)-X5@18  
6
6
E2E(Q)-X4@12  
E2E(Q)-X2@8  
4
E2E(Q)-X2@12  
4
2
2
E2E(Q)-X1R5@8  
0
0
-20 -15 -10 -5  
0
5
10 15 20  
Distance Y (mm)  
-20 -15 -10 -5  
0
5
10 15 20  
Distance Y (mm)  
Unshielded  
Unshielded  
30  
18  
16  
14  
12  
10  
8
E2E-X30M@30  
Y
X
Y
25  
E2E-X18M@30  
E2E-X10M@18  
X
E2E-X16M@18  
20  
15  
10  
5
E2E-X8M@12  
E2E-X4M@8  
E2E-X5M@12  
E2E-X2M@8  
6
4
2
0
0
-40 -30 -20 -10  
0
10 20 30 40  
Distance Y (mm)  
-40 -30 -20 -10  
0
10 20 30 40  
Distance Y (mm)  
48  
E2E/E2EQ NEXT Series  
Influence of Sensing Object Size and Material  
PREMIUM Model  
Shielded  
Quadruple distance model  
Size: M8 E2E-X4@8  
Triple distance model, Spatter-resistant Triple distance model  
Size: M8 E2E(Q)-X3@8  
4.0  
5
@d  
@d  
t=1mm  
t=1mm  
X
Iron  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
X
Iron  
4
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
3
Brass  
Brass  
2
Aluminum  
Aluminum  
Copper  
Copper  
1
0
0
5
10  
15  
20  
25  
30  
0
5
10  
15  
20  
25  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M12 E2E-X9@12  
Size: M12 E2E(Q)-X6@12  
10  
8
Iron  
@d  
t=1mm  
X
7
6
5
8
6
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
4
3
Brass  
Brass  
4
Aluminum  
Aluminum  
Copper  
2
@d  
Copper  
t=1mm  
2
X
1
0
0
0
0
10  
20  
30  
40  
50  
10  
20  
30  
40  
50  
Distance Y (mm)  
Side length of sensing object: d (mm)  
Size: M18 E2E-X14@18  
Size: M18 E2E(Q)-X12@18  
14  
16  
@d  
@d  
t=1mm  
X
t=1mm  
Iron  
Iron  
X
14  
12  
12  
10  
8
10  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
8
6
4
Brass  
Brass  
6
4
Aluminum  
Aluminum  
Copper  
Copper  
2
0
2
0
0
10  
20  
30  
40  
50  
60  
0
10  
20  
30  
40  
50  
60  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M30 E2E-X23@30  
Size: M30 E2E(Q)-X22@30  
30  
30  
@d  
t=1mm  
X
@d  
t=1mm  
X
25  
20  
25  
20  
15  
10  
5
Iron  
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
15  
10  
Brass  
Brass  
Aluminum  
Aluminum  
Copper  
Copper  
5
0
0
0
10 20 30 40 50 60 70 80 90  
Side length of sensing object: d (mm)  
0
10 20 30 40 50 60 70 80 90  
Side length of sensing object: d (mm)  
49  
E2E/E2EQ NEXT Series  
PREMIUM Model  
Unshielded  
Quadruple distance model  
Size: M8 E2E-X8M@8  
10  
Triple distance model  
Size: M8 E2E-X6M@8  
8
@d  
t=1mm  
@
d
t=1mm  
X
7
6
5
4
3
2
1
0
Iron  
X
Iron  
8
Stainless steel  
(SUS304)  
6
4
2
0
Stainless steel  
(SUS304)  
Brass  
Brass  
Aluminum  
Aluminum  
Copper  
Copper  
0
10  
20  
30  
40  
50  
0
10  
20  
30  
40  
50  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M12 E2E-X16M@12  
Size: M12 E2E-X10M@12  
12  
20  
@d  
t=1mm  
X
@d  
t=1mm  
X
Iron  
Iron  
10  
8
16  
12  
8
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
6
Brass  
Brass  
Aluminum  
4
Aluminum  
Copper  
Copper  
4
2
0
0
0
10  
20  
30  
40  
50  
60  
0
10  
20  
30  
40  
50  
60  
70  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M18 E2E-X30M@18  
Size: M18 E2E-X20M@18  
35  
25  
@d  
@d  
t=1mm  
X
t=1mm  
X
30  
Iron  
Iron  
20  
25  
20  
15  
10  
5
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
15  
10  
5
Brass  
Brass  
Aluminum  
Copper  
Aluminum  
Copper  
0
0
0
10 20 30 40 50 60 70 80 90  
Side length of sensing object: d (mm)  
0
10 20 30 40 50 60 70 80 90  
Side length of sensing object: d (mm)  
Size: M30 E2E-X50M@30  
Size: M30 E2E-X40M@30  
50  
60  
@d  
t=1mm  
X
@d  
t=1mm  
X
Iron  
Iron  
50  
40  
40  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
30  
20  
10  
0
30  
20  
Brass  
Brass  
Aluminum  
Copper  
Aluminum  
Copper  
10  
0
0
20  
40  
60  
80 100 120 140 160  
0
20  
40  
60  
80  
100  
120  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
50  
E2E/E2EQ NEXT Series  
BASIC Model  
Shielded  
Double distance model, Spatter-resistant Double distance model Single distance model, Spatter-resistant Single distance model  
Size: M8 E2E(Q)-X2@8  
Size: M8 E2E(Q)-X1R5@8  
2.5  
3.0  
@d  
@d  
t=1mm  
X
t=1mm  
X
2.5  
2.0  
1.5  
1.0  
0.5  
2.0  
1.5  
1.0  
Iron  
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Brass  
Brass  
0.5  
Aluminum  
Aluminum  
Copper  
20  
Copper  
20  
0
5
10  
15  
25  
0
5
10  
15  
25  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M12 E2E(Q)-X4@12  
Size: M12 E2E(Q)-X2@12  
3.0  
5
@d  
@d  
t=1mm  
X
t=1mm  
X
Iron  
2.5  
4
3
2
1
0
Iron  
Stainless steel  
(SUS304)  
2.0  
1.5  
1.0  
0.5  
Stainless steel  
(SUS304)  
Brass  
Brass  
Aluminum  
Aluminum  
Copper  
Copper  
0.0  
0
0
5
10  
15  
20  
25  
30  
5
10  
15  
20  
25  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M18 E2E(Q)-X8@18  
Size: M18 E2E(Q)-X5@18  
10  
6
@d  
@d  
t=1mm  
X
t=1mm  
X
Iron  
Iron  
5
8
6
4
2
0
Stainless steel  
(SUS304)  
4
3
2
Stainless steel  
(SUS304)  
Brass  
Brass  
Aluminum  
Aluminum  
Copper  
Copper  
1
0
0
10  
20  
30  
40  
50  
0
10  
20  
30  
40  
50  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M30 E2E(Q)-X15@30  
Size: M30 E2E(Q)-X10@30  
20  
12  
@d  
@d  
t=1mm  
X
t=1mm  
X
Iron  
10  
16  
12  
8
Iron  
Stainless steel  
(SUS304)  
8
6
4
Stainless steel  
(SUS304)  
Brass  
Brass  
Aluminum  
Aluminum  
Copper  
4
2
0
Copper  
0
10  
20  
30  
40  
50  
60  
0
0
10  
20  
30  
40  
50  
60  
70  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
51  
E2E/E2EQ NEXT Series  
BASIC Model  
Unshielded  
Double distance model  
Size: M8 E2E-X4M@8  
Single distance model  
Size: M8 E2E-X2M@8  
3.0  
5
@d  
@d  
Iron  
t=1mm  
X
t=1mm  
X
2.5  
2.0  
1.5  
1.0  
4
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
3
2
1
0
Brass  
Brass  
Aluminum  
Copper  
Aluminum  
Copper  
0.5  
0.0  
0
5
10  
15  
20  
25  
0
5
10  
15  
20  
25  
30  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M12 E2E-X8M@12  
Size: M12 E2E-X5M@12  
10  
6
@d  
@d  
Iron  
t=1mm  
X
t=1mm  
X
Iron  
5
4
3
2
8
6
4
2
0
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Brass  
Brass  
Aluminum  
Aluminum  
Copper  
Copper  
1
0
0
10  
20  
30  
40  
50  
0
10  
20  
30  
40  
50  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M18 E2E-X16M@18  
Size: M18 E2E-X10M@18  
12  
20  
@d  
@d  
t=1mm  
X
t=1mm  
Iron  
X
Iron  
10  
16  
8
6
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
12  
8
Brass  
Brass  
4
Aluminum  
Aluminum  
Copper  
Copper  
4
2
0
0
0
10  
20  
30  
40  
50  
60  
0
10  
20  
30  
40  
50  
60  
70  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Size: M30 E2E-X30M@30  
Size: M30 E2E-X18M@30  
25  
35  
@d  
@d  
t=1mm  
X
t=1mm  
Iron  
X
30  
20  
15  
10  
5
Iron  
25  
Stainless steel  
(SUS304)  
20  
15  
10  
5
Stainless steel  
(SUS304)  
Brass  
Aluminum  
Brass  
Aluminum  
Copper  
Copper  
0
0
0
10 20 30 40 50 60 70 80 90  
Side length of sensing object: d (mm)  
0
10 20 30 40 50 60 70 80 90  
Side length of sensing object: d (mm)  
52  
E2E/E2EQ NEXT Series  
Monitor Output vs. Sensing Distance  
PREMIUM Model  
Shielded  
Quadruple distance model  
Size: M8 E2E-X4@8  
Triple model, Spatter-resistant Triple distance model  
Size: M8 E2E(Q)-X3@8  
250  
250  
@d=9 mm  
@d=12 mm  
225  
225  
t=1 mm  
X
t=1 mm  
X
200  
200  
Iron  
175  
Iron  
175  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
150  
150  
125  
125  
Aluminum  
Aluminum  
100  
75  
100  
75  
50  
50  
25  
0
25  
0
0
1
2
3
4
5
0
1
2
3
4
5
Distance X (mm)  
Distance X (mm)  
Size: M12 E2E-X9@12  
Size: M12 E2E(Q)-X6@12  
250  
250  
@d=27 mm  
@d=18 mm  
t=1 mm  
225  
225  
t=1mm  
X
X
200  
200  
Iron  
175  
175  
150  
125  
100  
75  
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
150  
(SUS304)  
Aluminum  
125  
Aluminum  
100  
75  
50  
50  
25  
0
25  
0
0
3
6
9
12  
0
2
4
6
8
10  
Distance X (mm)  
Distance X (mm)  
Size: M18 E2E-X14@18  
Size: M18 E2E(Q)-X12@18  
250  
250  
@d=42 mm  
@d=36 mm  
t=1 mm  
225  
225  
t=1 mm  
X
X
200  
Iron  
200  
175  
150  
125  
100  
75  
Iron  
175  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
150  
125  
100  
75  
Aluminum  
Aluminum  
50  
50  
25  
0
25  
0
0
3.5  
7
10.5  
14  
17.5  
0
3
6
9
12  
15  
Distance X (mm)  
Distance X (mm)  
Size: M30 E2E-X23@30  
Size: M30 E2E(Q)-X22@30  
250  
250  
225  
@d=69 mm  
@d=66 mm  
t=1 mm  
225  
t=1 mm  
X
X
200  
175  
150  
125  
100  
75  
Iron  
Iron  
200  
175  
150  
125  
100  
75  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Aluminum  
Aluminum  
50  
50  
25  
0
25  
0
0
5
10  
15  
20  
25  
0
4
8
12  
16  
20  
24  
28  
Distance X (mm)  
Distance X (mm)  
53  
E2E/E2EQ NEXT Series  
PREMIUM Model  
Unshielded  
Quadruple distance model  
Size: M8 E2E-X8M@8  
Triple distance model  
Size: M8 E2E-X6M@8  
250  
250  
@d=18 mm  
t=1 mm  
@d=24 mm  
225  
225  
t=1 mm  
X
X
200  
200  
Iron  
Iron  
175  
175  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
150  
125  
100  
75  
150  
125  
Aluminum  
Aluminum  
100  
75  
50  
50  
25  
0
25  
0
0
2
4
6
8
10  
0
2
4
6
8
10  
Distance X (mm)  
Distance X (mm)  
Size: M12 E2E-X16M@12  
Size: M12 E2E-X10M@12  
250  
250  
225  
@d=48 mm  
@d=30 mm  
225  
t=1 mm  
t=1mm  
X
X
200  
175  
150  
125  
100  
75  
200  
175  
150  
125  
100  
75  
Iron  
Iron  
Stainless steel  
(SUS304)  
Aluminum  
Stainless steel  
(SUS304)  
Aluminum  
50  
50  
25  
0
25  
0
0
4
8
12  
16  
20  
0
2
4
6
8
10  
12  
14  
Distance X (mm)  
Distance X (mm)  
Size: M18 E2E-X30M@18  
Size: M18 E2E-X20M@18  
250  
250  
225  
@d=90 mm  
@d=60 mm  
225  
t=1 mm  
t=1 mm  
X
X
200  
175  
150  
125  
100  
75  
200  
175  
150  
125  
100  
75  
Iron  
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Aluminum  
Aluminum  
50  
50  
25  
0
25  
0
0
5
10  
15  
20  
25  
30  
35  
0
5
10  
15  
20  
25  
30  
Distance X (mm)  
Distance X (mm)  
Size: M30 E2E-X50M@30  
Size: M30 E2E-X40M@30  
250  
250  
@d=150 mm  
t=1 mm  
@d=120 mm  
t=1 mm  
225  
225  
X
X
200  
200  
Iron  
Iron  
175  
175  
Stainless steel  
Stainless steel  
150  
125  
100  
75  
150  
125  
100  
75  
(SUS304)  
Aluminum  
(SUS304)  
Aluminum  
50  
50  
25  
0
25  
0
0
10  
20  
30  
40  
50  
60  
0
8
16  
24  
32  
40  
48  
Distance X (mm)  
Distance X (mm)  
54  
E2E/E2EQ NEXT Series  
BASIC Model  
Shielded  
Double distance model, Spatter-resistant Double distance model Single distance model, Spatter-resistant Single distance model  
Size: M8 E2E(Q)-X2@8  
Size: M8 E2E(Q)-X1R5@8  
250  
250  
@d=8 mm  
@d=8 mm  
225  
225  
t=1 mm  
t=1 mm  
X
X
200  
175  
150  
125  
100  
75  
200  
175  
Iron  
Iron  
Stainless steel  
(SUS304)  
150  
Stainless steel  
(SUS304)  
125  
Aluminum  
100  
75  
Aluminum  
50  
50  
25  
0
25  
0
0
0.5  
1
1.5  
2
2.5  
3
3.5  
4
0
0.5  
1
1.5  
2
2.5  
3
Distance X (mm)  
Distance X (mm)  
Size: M12 E2E(Q)-X4@12  
Size: M12 E2E(Q)-X2@12  
250  
250  
@d=12 mm  
@d=12 mm  
225  
225  
t=1 mm  
t=1 mm  
X
X
200  
200  
175  
150  
125  
100  
75  
175  
Iron  
Iron  
Stainless steel  
(SUS304)  
150  
Stainless steel  
(SUS304)  
125  
100  
75  
Aluminum  
Aluminum  
50  
50  
25  
0
25  
0
0
0.5  
1
1.5  
2
2.5  
3
3.5  
4
0
1
2
3
4
5
6
7
8
Distance X (mm)  
Distance X (mm)  
Size: M18 E2E(Q)-X8@18  
Size: M18 E2E(Q)-X5@18  
250  
250  
@d=18 mm  
@d=24 mm  
225  
225  
t=1 mm  
t=1mm  
X
X
200  
200  
175  
150  
125  
100  
75  
Iron  
175  
150  
125  
100  
75  
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Aluminum  
Aluminum  
50  
50  
25  
0
25  
0
0
1
2
3
4
5
6
7
8
9
10  
0
2
4
6
8
10  
12  
14  
16  
Distance X (mm)  
Distance X (mm)  
Size: M30 E2E(Q)-X15@30  
Size: M30 E2E(Q)-X10@30  
250  
250  
@d=30 mm  
@d=45 mm  
225  
225  
t=1mm  
t=1 mm  
X
X
200  
200  
Iron  
175  
175  
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
150  
125  
100  
75  
150  
125  
Aluminum  
Aluminum  
100  
75  
50  
50  
25  
0
25  
0
0
2
4
6
8
10 12 14 16 18 20  
Distance X (mm)  
0
3
6
9
12 15 18 21 24 27 30  
Distance X (mm)  
55  
E2E/E2EQ NEXT Series  
BASIC Model  
Unshielded  
Double distance model  
Single distance model  
Size: M8 E2E-X4M@8  
250  
Size: M8 E2E-X2M@8  
250  
@d=12 mm  
@d=8 mm  
225  
225  
t=1mm  
X
t=1mm  
X
200  
175  
150  
125  
100  
75  
200  
175  
150  
125  
100  
75  
Iron  
Stainless steel  
(SUS304)  
Iron  
Stainless steel  
(SUS304)  
Aluminum  
Aluminum  
50  
50  
25  
0
25  
0
0
1
2
3
4
5
6
7
8
0
0.5  
1
1.5  
2
2.5  
3
3.5  
4
Distance X (mm)  
Distance X (mm)  
Size: M12 E2E-X8M@12  
250  
Size: M12 E2E-X5M@12  
250  
@d=15 mm  
@d=24 mm  
225  
225  
t=1mm  
t=1mm  
X
X
200  
175  
150  
125  
100  
75  
200  
Iron  
175  
Iron  
150  
125  
100  
75  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Aluminum  
Aluminum  
50  
50  
25  
0
25  
0
0
1
2
3
4
5
6
7
8
9
10  
0
2
4
6
8
10  
12  
14  
16  
Distance X (mm)  
Distance X (mm)  
Size: M18 E2E-X16M@18  
Size: M18 E2E-X10M@18  
250  
250  
@d=48 mm  
@d=30 mm  
225  
225  
t=1mm  
t=1mm  
X
X
200  
175  
150  
125  
100  
75  
200  
Iron  
175  
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
150  
(SUS304)  
125  
Aluminum  
Aluminum  
100  
75  
50  
50  
25  
0
25  
0
0
2
4
6
8
10 12 14 16 18 20  
Distance X (mm)  
0
4
8
12  
16  
20  
24  
28  
32  
Distance X (mm)  
Size: M30 E2E-X30M@30  
Size: M30 E2E-X18M@30  
250  
250  
@d=90 mm  
@d=54 mm  
225  
225  
t=1mm  
t=1mm  
X
X
200  
200  
Iron  
175  
175  
Iron  
Stainless steel  
150  
150  
125  
100  
75  
Stainless steel  
(SUS304)  
(SUS304)  
125  
Aluminum  
Aluminum  
100  
75  
50  
50  
25  
0
25  
0
0
3
6
9
12 15 18 21 24 27 30 33 36  
Distance X (mm)  
0
10  
20  
30  
40  
50  
60  
Distance X (mm)  
56  
E2E/E2EQ NEXT Series  
I/O Circuit Diagrams/Timing charts  
DC 3-Wire  
PNP output  
Output circuit  
IO-Link Communication mode (COM mode)  
When using the Sensor connected to IO-  
Link Master Unit *  
Operation mode  
Model  
Standard I/O mode (SIO mode)  
When using as a general  
DC10 to 30V  
Brown (1)  
L+ (1)  
Brown (1)  
+V  
Proximity  
sensor  
Black (4)  
Proximity  
sensor  
main  
C/Q (4)  
NO  
E2E(Q)-@B1  
Black (4)  
main  
circuit  
OUT  
circuit  
Load  
Blue (3)  
Blue (3)  
L- (3)  
0V  
IO-Link master  
DC10 to 30V  
Brown (1)  
+V  
OUT  
0V  
Proximity  
sensor  
main  
Black (2)  
NC  
E2E(Q)-@B2  
---  
circuit  
Load  
Blue (3)  
Note: M8 (3-pin) Connector: (1)(4)(3)  
DC10 to 30V  
DC10 to 30V  
Brown (1)  
L+ (1)  
Brown (1)  
+V  
Black (4)  
Black (4)  
OUT1  
C/Q (4)  
Proximity  
sensor  
main  
Proximity  
sensor  
main  
NO+NC  
E2E(Q)-@B3  
Load  
circuit  
White (3)  
OUT2  
White (3)  
OUT2  
circuit  
DI (2)  
Load  
Blue (3)  
Blue (3)  
L- (3)  
0V  
IO-Link master  
* In the IO-Link mode, the cord between the IO-Link master and sensor must have a length of 20 m or less.  
Connector Pin Arrangement  
M12 Connector  
M8 (4-pin) Connector  
M12 Smartclick Connector  
M8 (3-pin) Connector  
1
3
2
4
4
1
3
1
3
2
4
57  
E2E/E2EQ NEXT Series  
PNP output  
Set position  
Excessive proximity judgment distance *7  
ProximitySensor  
Unstable  
Sensing  
area  
Nonsensing  
area  
Stable  
Sensing area  
Operation  
mode *1  
Output mode  
Sensing  
object  
Rated Sensing distance  
100 80  
20  
0
(%)  
ON  
Comunication indicator (green) : Always OFF  
OFF  
ON  
Operation indicator (orange)  
Control output *3  
NO  
NC  
OFF  
ON  
OFF  
*3. The timer function of the control  
output can be set up by the IO-Link  
communications. (It is able to select  
ON delay, OFF delay, or one-shot  
function and select a timer time of 1  
to 16,383ms (T).)  
ON  
Comunication indicator (green) : Always OFF  
Operation indicator (orange)  
Control output *3  
OFF  
ON  
OFF  
ON  
Standard  
I/O mode  
(SIO mode) *2  
OFF  
ON delay  
OFF delay  
ON  
Comunication indicator (green) : Always OFF  
Operation indicator (orange)  
Control output 1 *3  
Sensing Present  
Sensing Present  
OFF  
ON  
object  
Not  
object  
Not  
present  
present  
T
T
ON  
1
0
1
0
ON  
1
0
1
0
NO  
NC  
NO  
NC  
OFF  
ON  
OFF  
ON  
NO+NC  
OFF  
ON  
T
T
OFF  
OFF  
OFF  
ON  
Control output 2 *3  
One shot  
OFF  
Sensing Present  
object  
Not  
present  
Flashing  
T
ON  
1
0
1
0
(1sec cycle) Comunication indicator (green)  
NO  
NC  
OFF  
ON  
T
ON  
Operation indicator (orange)  
OFF  
OFF  
1
*4. The excessive proximity diagnosis  
function can be selected by the IO-  
Link communications.  
*5. The instability detection diagnosis  
can be selected by the IO-Link  
communications.  
NO  
Control output (PD1_bit0) *3  
0
1
Instability detection *6 (PD1_bit4)  
0
*
5
1
Excessive proximity detection (PD1_bit5)  
*4  
0
*6. The judgment time for the instability  
detection diagnosis can be selected  
by the IO-Link communications.  
(For the ON delay timer function, the  
setting can be selected from 0  
(invalid), 10, 50, 100, 300, 500, or  
1000 ms.)  
*7. The judgment distance of the  
excessive proximity diagnosis  
function can be selected by the IO-  
Link communications.  
Flashing  
(1sec cycle) Comunication indicator (green)  
ON  
Operation indicator (orange)  
OFF  
1
Control output (PD1_bit0) *3  
IO-Link  
Communication  
mode  
NC  
0
1
Instability detection *6 (PD1_bit4)  
*
5
(COM mode)  
0
1
0
Excessive proximity detection (PD1_bit5)  
*
4
Flashing  
(The distance can be selected as a  
combination of the material of the  
object detected, such as iron,  
aluminum, or SUS and the judgment  
distance of approximately 10, 20, or  
30%. However, it is not allowed to  
select a combination of aluminum  
and 30%.)  
(1sec cycle) Comunication indicator (green)  
ON  
Operation indicator (orange)  
OFF  
1
Control output1 (PD1_bit0) *3  
0
NO+NC  
1
Control output2 (PD1_bit1) *3  
0
1
Instability detection *6 (PD1_bit4)  
*
5
Please contact your OMRON sales  
representative regarding the IO-Link  
setup file (IODD file).  
0
1
0
Excessive proximity detection (PD1_bit5)  
*4  
Please contact your OMRON sales representative regarding assignment of data.  
*1. For models with IO-Link, the operation mode can be changed by the IO-Link communications.  
*2. If using a model with IO-Link as a general sensor or using a model without IO-Link, it operates in the standard I/O mode (SIO mode).  
58  
E2E/E2EQ NEXT Series  
NPN output  
Operation mode  
Model  
Output circuit  
DC10 to 30V  
Brown (1)  
+V  
Load  
Proximity  
sensor  
main  
NO  
E2E(Q)-@C1  
OUT  
0V  
Black (4)  
Blue (3)  
circuit  
DC10 to 30V  
Brown (1)  
+V  
Load  
Proximity  
sensor  
main  
OUT  
0V  
NC  
E2E(Q)-@C2  
Black (2)  
Blue (3)  
circuit  
Note: M8 (3-pin) Connector: (1)(4)(3)  
DC10 to 30V  
+V  
Brown (1)  
Load  
Proximity  
sensor  
main  
Black (4)  
NO+NC  
E2E(Q)-@C3  
Load  
circuit  
OUT2  
White (3)  
Blue (3)  
0V  
Connector Pin Arrangement  
M12 Connector  
M12 Smartclick Connector  
M8 (4-pin) Connector  
M8 (3-pin) Connector  
1
2
4
4
2
4
3
1
1
3
3
Nonsensing  
area  
Stable  
sensing area  
ProximitySensor  
Sensing  
object  
Operation mode  
Rated Sensing distance  
100  
0
(%)  
ON  
Operation indicator (orange)  
Control output  
OFF  
ON  
NO  
NC  
OFF  
ON  
Operation indicator (orange)  
Control output  
OFF  
ON  
OFF  
ON  
Operation indicator (orange)  
Control output 1  
OFF  
ON  
NO+NC  
OFF  
ON  
Control output 2  
OFF  
59  
E2E/E2EQ NEXT Series  
Connections for Sensor I/O Connectors  
DC 3-Wire  
Proximity Sensor  
Operation  
Sensor I/O Connectors  
Connections *  
Types  
Output  
Model  
Model  
mode  
E2E/E2EQ NEXT Series  
XS5  
*
1
2
3
4
1
2
3
4
Brown (+)  
NO  
E2E(Q)-X@B1@- M1TJ/ M1  
White (not connected)  
Blue (–)  
Black (Output)  
E2E/E2EQ NEXT Series  
XS5  
*
1
2
3
4
1
2
3
4
Brown (+)  
PNP  
NC  
NO+NC  
NO  
E2E(Q)-X@B2@-M1TJ/M1  
E2E(Q)-X@B3@-M1TJ/M1  
E2E(Q)-X@C1@-M1TJ/M1  
E2E(Q)-X@C2@-M1TJ/M1  
E2E(Q)-X@C3@-M1TJ/M1  
E2E(Q)-X@B1@-M3  
White (Output)  
Blue (-)  
Black (not connected)  
E2E/E2EQ NEXT Series  
XS5  
XS5F-D421-@80-X@  
XS5F-D42@-@80-F  
XS5W-D421-@81-X@  
XS5W-D42@-@81-F  
*
1
2
3
4
1
2
3
4
Brown (+)  
White (Output 2)  
Blue (-)  
Black (Output 1)  
DC 3-Wire  
(M12 Connector/  
M12 Smartclick  
Connector)  
Note: For details of the  
connector,  
E2E/E2EQ NEXT Series  
XS5  
*
refer to XS5 NEXT  
Series on page 87  
refer to XS5 Series  
on page 94  
1
2
3
4
1
2
3
4
Brown (+)  
White (not connected)  
Blue (-)  
Black (Output)  
E2E/E2EQ NEXT Series  
XS5  
*
1
2
3
4
1
2
3
4
Brown (+)  
NPN  
NC  
White (Output)  
Blue (-)  
Black (not connected)  
E2E/E2EQ NEXT Series  
XS5  
*
1
2
3
4
1
2
3
4
Brown (+)  
White (Output 2)  
Blue (-)  
NO+NC  
Black (Output 1)  
E2E/E2EQ NEXT Series  
XS3  
*
1
2
3
4
1
2
3
4
Brown (+)  
NO  
White (not connected)  
Blue (-)  
Black (Output)  
PNP  
E2E/E2EQ NEXT Series  
XS3  
*
1
2
3
4
1
2
3
4
Brown (+)  
NC  
E2E(Q)-X@B2@-M3  
XS3W-M8PVC4@  
XS3F-M8PVC4@  
White (Output)  
Blue (-)  
Black (not connected)  
DC 3-Wire  
(M8 Connector,  
4-pin)  
Note: For details of the  
connector,  
E2E/E2EQ NEXT Series  
XS3  
refer to XS3W-M8/  
XS3F-M8 Series  
on page 102.  
*
1
2
3
4
1
2
3
4
Brown (+)  
NO  
E2E(Q)-X@C1@-M3  
White (not connected)  
Blue (-)  
Black (Output)  
NPN  
E2E/E2EQ NEXT Series  
XS3  
*
1
2
3
4
1
2
3
4
Brown (+)  
NC  
E2E(Q)-X@C2@-M3  
White (Output)  
Blue (-)  
Black (not connected)  
E2E/E2EQ NEXT Series  
XS3  
NO  
NC  
NO  
NC  
E2E(Q)-X@B1@-M5  
E2E(Q)-X@B2@-M5  
E2E(Q)-X@C1@-M5  
E2E(Q)-X@C2@-M5  
*
1
1
Brown (+)  
PNP  
NPN  
XS3W-M8PVC3@  
XS3F-M8PVC3@  
4
3
4
3
Black (Output)  
Blue (-)  
DC 3-Wire  
(M8 Connector,  
3-pin)  
Note: For details of the  
connector,  
E2E/E2EQ NEXT Series  
XS3  
refer to XS3W-M8/  
XS3F-M8 Series  
on page 102.  
*
1
1
Brown (+)  
4
3
4
3
Black (Output)  
Blue (-)  
Note: Different from Proximity Sensor wire colors.  
* If the XS5W Series or XS3W Series Connector which has a socket and plug on the cable ends is connected to the Sensor, this part will be a plug.  
60  
E2E/E2EQ NEXT Series  
Safety Precautions  
Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/.  
Warning Indications  
Precautions for Correct Use  
Warning level  
Do not use the product in any atmosphere or environment that  
Indicates a potentially hazardous situation  
exceeds the ratings.  
which, if not avoided, will result in minor or  
WARNING  
Operating Environment  
1. Do not install the Sensor in the following locations.  
(1) Outdoor locations directly subject to sunlight, rain, snow,  
waterdroplets, or oil.  
(2) Locations subject to atmospheres with chemical vapors,  
inparticular solvents and acids.  
moderate injury, or may result in serious  
injury or death. Additionally there may be  
significant property damage.  
Precautions  
for Safe Use  
Supplementary comments on what to do or  
avoid doing, to use the product safely.  
(3) Locations subject to corrosive gases.  
Supplementary comments on what to do or  
avoid doing, to prevent failure to operate,  
malfunction or undesirable effect on product  
performance.  
Precautions  
for Correct  
Use  
2. The Sensor may malfunction if used near ultrasonic cleaning  
equipment, high-frequency equipment, transceivers, cellular  
phones, inverters, or other devices that generate a high-frequency  
electric field. Please refer to the Precautions for Correct Use on  
the OMRON website (www.ia.omron.com) for typical measures.  
3. Laying the Proximity Sensor wiring in the same conduit or duct as  
high-voltage wires or power lines may result in incorrect operation  
and damage due to induction. Wire the Sensor using a separate  
conduit or independent conduit.  
Meaning of Product Safety Symbols  
General prohibition  
Indicates the instructions of unspecified  
prohibited action.  
4. Never use thinner or other solvents. Otherwise, the Sensor  
surface may be dissolved.  
Caution, explosion  
Indicates the possibility of explosion under  
specific conditions.  
5. The following conditions shall be observed if you use the product  
under an environment using cutting oil that may affect product’s  
life and/or performance.  
• Usage under the cutting oil condition designated by the  
specification  
• Usage under the cutting oil dilution ratio recommended by its  
manufacturer  
• Usage in oil or water is prohibited  
WARNING  
This product is not designed or rated for ensuring  
safety of persons either directly or indirectly.  
Do not use it for such purposes.  
Impact on the product life may differ depending on the oil you use.  
Before using the cutting oil, make sure that it should not cause  
deterioration or degradation of sealing components.  
6. When turning on the power by influence of temperature  
environment, an outputmis-pulse sometimes occurs. After the  
sensor has passed for 300 msec after turning on, please use in the  
stable state.  
Otherwise, explosion may result.  
Never use the product with an AC power supply.  
7. The sensor is adjusted with a high degree of accuracy, so do not  
use in the environment with sudden temperature change.  
8. Operation check is performed using an OMRON's IO-Link master.  
If using an IO-Link master from another company, perform the  
operation check in advance.  
Precautions for Safe Use  
The following precautions must be observed to ensure safe operation.  
1. Do not use the product in environments subject to flammable or  
explosive gases.  
2. Do not attempt to disassemble, repair, or modify the product.  
3. Do not use a voltage that exceeds the rated operating voltage  
range.  
Applying a voltage that is higher than the operating voltage range  
may result in explosion or fire.  
4. Be sure that the power supply polarity and other wiring is correct.  
Incorrect wiring may cause explosion or fire.  
5. If the power supply is connected directly without a load, the  
internal elements may explode or burn.  
6. Be sure to insert a load when connecting the power supply.  
61  
E2E/E2EQ NEXT Series  
When the Proximity Sensor is mounted in metal, ensure that the  
minimum distances given in the following table are maintained.  
Design  
Influence of Surrounding Metal  
When mounting the Proximity Sensor using a nut, only use the  
provided nut. And ensure that the minimum distances given in the  
following table are maintained.  
When mounting the Proximity Sensor using a nut, only use the  
provided nut. Nuts that are supplied along with each Sensor are  
different. Refer to Dimensions for details on shapes.  
(Unit: mm)  
Shielded  
Models  
Model  
E2E-X4@8  
I
4
d
30  
40  
60  
100  
20  
20  
50  
70  
8
D
4
m
12  
27  
42  
69  
9
n
20  
30  
70  
100  
18  
20  
54  
90  
12  
18  
27  
45  
12  
18  
27  
45  
E2E-X9@12  
6
6
Quadruple  
distance model  
(Unit: mm)  
E2E-X14@18  
7
7
Shielded  
E2E-X23@30  
9
9
Type  
Model  
E2E-X4@8  
L
3
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
d
30  
40  
60  
100  
20  
20  
50  
70  
8
D
3
2
2
2
0
0
0
0
0
0
0
0
0
0
0
0
m
12  
27  
42  
69  
9
n
20  
30  
70  
100  
18  
20  
54  
90  
12  
18  
27  
45  
12  
18  
27  
45  
E2E(Q)-X3@8  
E2E(Q)-X6@12  
E2E(Q)-X12@18  
E2E(Q)-X22@30  
E2E(Q)-X2@8  
E2E(Q)-X4@12  
E2E(Q)-X8@18  
E2E(Q)-X15@30  
E2E(Q)-X1R5@8  
E2E(Q)-X2@12  
E2E(Q)-X5@18  
E2E(Q)-X10@30  
2
2
Triple distance  
model/  
Spatter-resistant  
Triple distance  
model  
4
4
18  
36  
66  
4.5  
12  
24  
45  
4.5  
8
E2E-X9@12  
Quadruple  
distance model  
4
4
E2E-X14@18  
8
8
E2E-X23@30  
0
0
Double distance  
model/  
Spatter-resistant  
Double distance  
model  
E2E(Q)-X3@8  
E2E(Q)-X6@12  
E2E(Q)-X12@18  
E2E(Q)-X22@30  
E2E(Q)-X2@8  
E2E(Q)-X4@12  
E2E(Q)-X8@18  
E2E(Q)-X15@30  
E2E(Q)-X1R5@8  
E2E(Q)-X2@12  
E2E(Q)-X5@18  
E2E(Q)-X10@30  
Triple distance  
model/  
Spatter-resistant  
Triple distance  
model  
2.4  
3.6  
6
18  
27  
45  
8
2.4  
3.6  
6
18  
36  
66  
4.5  
12  
24  
45  
4.5  
8
0
0
Single distance  
model/  
Spatter-resistant  
Single distance  
model  
Double distance  
model/  
Spatter-resistant  
Double distance  
model  
0
12  
18  
30  
0
18  
27  
45  
8
0
0
20  
40  
0
0
Unshielded  
Single distance  
model/  
Spatter-resistant  
Single distance  
model  
12  
18  
30  
Models  
Model  
E2E-X8M@8  
I
d
40  
D
m
24  
48  
90  
n
20  
40  
15  
25  
50  
65  
13  
20  
35  
55  
12  
15  
25  
45  
6
15  
25  
50  
65  
13  
20  
35  
55  
12  
15  
25  
45  
6
40  
E2E-X16M@12  
E2E-X30M@18  
E2E-X50M@30  
E2E-X6M@8  
70  
80  
Quadruple  
distance model  
130  
200  
30  
110  
Unshielded  
150 180  
Models  
Model  
E2E-X8M@8  
L
d
40  
D
m
24  
48  
90  
n
40  
18  
30  
60  
30  
50  
80  
12  
21  
46  
60  
10  
16  
31  
50  
9
12  
21  
46  
60  
10  
16  
31  
50  
9
E2E-X10M@12  
E2E-X20M@18  
E2E-X40M@30 *  
E2E-X4M@8  
50  
Triple distance  
model  
E2E-X16M@12  
E2E-X30M@18  
E2E-X50M@30  
E2E-X6M@8  
70  
80  
Quadruple  
distance model  
90  
130  
200  
30  
110  
170  
24  
120 140  
150 180  
8
24  
40  
70  
120  
24  
36  
54  
90  
18  
30  
60  
30  
50  
80  
E2E-X8M@12  
E2E-X16M@18  
E2E-X30M@30  
E2E-X2M@8  
40  
20  
48  
90  
8
Double distance  
model  
E2E-X10M@12  
E2E-X20M@18  
E2E-X40M@30 *  
E2E-X4M@8  
50  
Triple distance  
model  
70  
90  
120  
24  
170  
24  
120 140  
8
24  
40  
70  
120  
24  
36  
54  
90  
E2E-X5M@12  
E2E-X10M@18  
E2E-X18M@30  
15  
22  
30  
40  
15  
22  
30  
20  
40  
70  
Single distance  
model  
E2E-X8M@12  
E2E-X16M@18  
E2E-X30M@30  
E2E-X2M@8  
11  
21  
40  
6
40  
11  
21  
40  
6
20  
48  
90  
8
Double distance  
model  
55  
70  
90  
120  
24  
* If you use the model E2E-X40M@30, the panel thickness (t) is 4 mm  
or less.  
E2E-X5M@12  
E2E-X10M@18  
E2E-X18M@30  
11  
18  
25  
40  
11  
18  
25  
20  
40  
70  
Single distance  
model  
55  
90  
* If you use the model E2E-X40M@30, the panel thickness (t) is 4 mm  
or less.  
62  
E2E/E2EQ NEXT Series  
Mutual Interference  
When installing two or more Proximity Sensors face-to-face or side-  
by-side, ensure that the minimum distances given in the following  
table are maintained.  
Mounting  
Tightening Force  
Do not tighten the nut with excessive force.  
A washer must be used with the nut.  
Shielded Models  
Unshielded Models  
B
A
Part B Part A  
Part B Part A  
Note: 1. The allowable tightening strength depends on the distance  
from the edge of the head, as shown in the following table.  
(A is the distance from the edge of the head. B includes the  
nut on the head side. If the edge of the nut is in part A, the  
tightening torque for part A applies instead.)  
(Unit: mm)  
Shielded  
Item  
Models  
Model  
E2E-X4@8  
A
40  
B
2. The following strengths assume washers are being used.  
20  
35  
50  
90  
20  
30  
45  
90  
15  
20  
35  
90  
15  
20  
35  
70  
Quadruple distance model, Triple distance model,  
Spatter-resistant Triple distance model  
E2E-X9@12  
60  
Quadruple  
distance model  
E2E-X14@18  
90  
Part A  
Part B  
E2E-X23@30  
150  
25  
Size  
Shielded  
Dimension  
(mm)  
E2E(Q)-X3@8  
E2E(Q)-X6@12  
E2E(Q)-X12@18  
E2E(Q)-X22@30  
E2E(Q)-X2@8  
E2E(Q)-X4@12  
E2E(Q)-X8@18  
E2E(Q)-X15@30  
E2E(Q)-X1R5@8  
E2E(Q)-X2@12  
E2E(Q)-X5@18  
E2E(Q)-X10@30  
Triple distance  
model/  
Spatter-resistant  
Triple distance  
model  
Torque  
Torque  
40  
Shielded  
9
3
70  
M8  
4 N·m  
10 N·m  
15 N·m  
Unshielded  
Shielded  
150  
20  
16  
9
Double distance  
model/  
Spatter-resistant  
Double distance  
model  
M12  
M18  
M30  
6 N·m  
15 N·m  
40 N·m  
Unshielded  
Shielded  
30  
16  
3
60 N·m  
(30 N·m *)  
60  
Unshielded  
Shielded  
110  
20  
23  
8
Single distance  
model/  
Spatter-resistant  
Single distance  
model  
80 N·m  
Unshielded  
30  
* If using the E2EQ (M18), refer to this torque value.  
50  
100  
Double distance model, Single distance model,  
Spatter-resistant Triple distance model,  
Spatter-resistant Single distance model  
Unshielded  
Item  
Part A  
Part B  
Models  
Model  
A
B
Size  
Shielded  
Dimension  
(mm)  
Torque  
Torque  
E2E-X8M@8  
80  
60  
E2E-X16M@12  
E2E-X30M@18  
E2E-X50M@30  
E2E-X6M@8  
160  
360  
700  
80  
120  
300  
480  
60  
Shielded  
9
Quadruple  
distance model  
M8  
9 N·m  
12 N·m  
Unshielded  
3
M12  
M18  
M30  
---  
---  
---  
---  
---  
---  
30 N·m  
70 N·m  
E2E-X10M@12  
E2E-X20M@18  
E2E-X40M@30  
E2E-X4M@8  
120  
200  
380  
80  
100  
120  
300  
60  
180 N·m (100 N·m *)  
Triple distance  
model  
* If using the E2EQ (M30), refer to this torque value.  
E2E-X8M@12  
E2E-X16M@18  
E2E-X30M@30  
E2E-X2M@8  
120  
200  
350  
80  
100  
120  
300  
60  
Double distance  
model  
E2E-X5M@12  
E2E-X10M@18  
E2E-X18M@30  
120  
200  
300  
100  
110  
200  
Single distance  
model  
63  
E2E/E2EQ NEXT Series  
Dimensions  
(Unit: mm)  
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.  
Sensors  
PREMIUM Model  
E2E/E2EQ NEXT Series  
(Quadruple distance/Triple distance/Spatter-resistant, Triple distance model)  
DC 3-Wire  
Pre-wired Model/Pre-wired Connector Model  
Shielded/Unshielded  
Connector Models  
(M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)  
Shielded/Unshielded  
B
B
C
D
Indicators  
D
F
Indicators  
F
Standard I/O mode (SIO mode):  
Operation indicator (orange/ON),  
comunication indicator (green/OFF)  
IO-Link Communication mode (COM mode):  
Operation indicator (orange/ON),  
comunication indicator  
G
H
G
H
E
Standard I/O mode (SIO mode):  
Operation indicator (orange/ON),  
communication indicator (green/OFF)  
IO-Link Communication mode (COM mode):  
Operation indicator (orange/ON),  
comunication indicator  
I
E
I
(green/Flashing (1sec cycle)  
(green/Flashing (1sec cycle)  
A
C
A
J
Two clamping nuts  
Toothed washer  
J
Toothed washer  
Two clamping nuts  
Pre-wired Models  
(Operation mode: NO, NC Type)  
Pre-wired Connector Models (M1TJ)  
M12×P1  
Model E2E(Q)-X@8-M1;  
Shape of connection.  
Shielded  
Model  
Vinyl-insulated round cable with  
3 conductors  
M8, M12 size: 4-dia.  
M18, M30 size: 6-dia.  
(Conductor cross section:  
0.2 mm2 (AWG24),  
Insulator diameter: 1.05 mm),  
Standard length: 2 m  
A
B
C
D
E
F
G*  
H
4
4
I
J
(Operation mode: NO, NC Type)  
Vinyl-insulated round cable with  
3 conductors  
M8, M12 size: 4-dia.  
M18, M30 size: 6-dia.  
(Conductor cross section:  
0.2 mm2 (AWG24),  
Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
E2E(Q)-X@8-M3/  
M5  
M8XP1 39 M8XP1  
26  
1
10  
4
15 13  
E2E(Q)-X@8-M1 M8XP1 43 M12XP1 26  
E2E(Q)-X@12-M1 M12XP1 48 M12XP1 33  
E2E(Q)-X@18-M1 M18XP1 53 M12XP1 38  
E2E(Q)-X@30-M1 M30XP1.5 58 M12XP1 43  
1
1
1
1
1
1
1
1
1
10  
12  
12  
12  
4
4
4
4
15 13  
5.5 21 17  
6
7
4
4
29 24  
42 36  
15 13  
15 13  
(Operation mode: NO+NC Type)  
(Operation mode: NO+NC Type)  
Vinyl-insulated round cable with  
4 conductors  
E2E-X@L8-M3/M5 M8XP1 49 M8XP1  
36  
10 ---  
10 ---  
E2E-X@L8-M1  
E2E-X@L12-M1  
E2E-X@L18-M1  
E2E-X@L30-M1  
M8XP1 53 M12XP1 36  
M12 size: 4.3-dia.  
Vinyl-insulated round cable with  
4 conductors  
M12 size: 4.3-dia.  
M18/M30 size: 6-dia.  
(Conductor cross section: 0.2 mm2  
(AWG24),  
M18, M30 size: 6-dia.  
(Conductor cross section: 0.2 mm2  
(AWG24),  
Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
M12XP1 70 M12XP1 55  
M18XP1 75 M12XP1 60  
M30XP1.5 80 M12XP1 65  
12 --- 5.5 21 17  
12 ---  
12 ---  
6
7
29 24  
42 36  
Insulator diameter: 1.05 mm),  
Standard length: 2 m  
Unshielded  
Model  
A
B
C
D
E
F
8
8
G*  
---  
---  
H
I
J
Shielded  
E2E-X@M@8-M3/  
M5  
M8XP1 39 M8XP1  
26  
6
3
15 13  
Model  
A
B
C
D
E
1
1
1
1
1
1
1
1
F
G*  
4
H
I
J
E2E(Q)-X@8  
M8XP1  
37.8 4.4 26  
47.1 3.7 33  
55.3 8.5 38  
10  
12  
12  
12  
4
15 13  
E2E-X@M@8-M1 M8XP1 43 M12XP1 26  
E2E-X 12-M1 M12XP1 48 M12XP1 33  
L8-M3/M5 M8XP1 49 M8XP1 36  
M8XP1 53 M12XP1 36  
L12-M1 M12XP1 70 M12XP1 55  
6
7
6
6
7
3
4
3
3
4
4
5
5
15 13  
21 17  
15 13  
15 13  
21 17  
29 24  
42 36  
42 36  
E2E(Q)-X@12 M12XP1  
E2E(Q)-X@18 M18XP1  
4
5.5 21 17  
@M@  
10 ---  
4
6
7
4
29 24  
42 36  
15 13  
E2E-X@M@  
8
8
---  
---  
E2E(Q)-X@30 M30XP1.5 60.3 8.3 43  
4
E2E-X  
E2E-X  
E2E-X  
@
@
@
M
M
M
@
@
@
L8-M1  
E2E-X@L8  
E2E-X@L12  
E2E-X@L18  
E2E-X@L30  
M8XP1  
47.8 4.4 36  
69.1 3.7 55  
77.3 8.5 60  
10 ---  
10 ---  
M12XP1  
M18XP1  
12 --- 5.5 21 17  
L18-M1 M18XP1 75 M12XP1 60 13 12 ---  
L30-M1 M30XP1.5 80 M12XP1 65 15 10 ---  
L30-M1 M30XP1.5 95 M12XP1 80 15 12 ---  
12 ---  
12 ---  
6
7
29 24  
42 36  
E2E-X40M  
@
@
M30XP1.5 82.3 8.3 65  
E2E-X50M  
* Mounting part of sensor lock O-ring (Y92E-J@S@) ---:Out of a subject.  
Unshielded  
Model  
A
B
C
D
E
6
7
F
G*  
H
3
4
I
J
Mounting Hole Dimensions  
Angle R of the  
Bending Wire  
10 mm  
Wire pullout position  
E2E-X@M@8 M8XP1  
E2E-X@M@12 M12XP1  
37.8 4.4 26  
47.1 3.7 33  
8
---  
15 13  
21 17  
Sc  
10 ---  
---  
10 ---  
E2E-  
F
M8XP1  
X@M@L8  
47.8 4.4 36  
69.1 3.7 55  
6
7
8
3
15 13  
R
Dimensions  
M8  
F (mm)  
E2E-X  
@
M
@
L12 M12XP1  
L18 M18XP1  
4
4
5
5
21 17  
29 24  
42 36  
42 36  
Dimensions Sc (mm)  
Dimensions R (mm)  
+0.5  
0
8.5 dia.  
E2E-X@  
M
@
77.3 8.5 60 13 12 ---  
M8  
- (0)  
M12  
M8  
12  
+0.5  
0
M12  
M18  
M30  
12.5 dia.  
18.5 dia.  
30.5 dia.  
E2E-S05S12  
@
@
M30XP1.5 82.3 8.3 65 15 10 ---  
M12  
+0.5  
0
E2E-S05S12  
M30X1.5  
97.3 8.3 80 15 12 ---  
M18  
2.5  
M18  
18  
+0.5  
0
M30  
M30  
* Mounting part of sensor lock O-ring (Y92E-J@S@) ---: Out of a subject.  
64  
E2E/E2EQ NEXT Series  
BASIC Model  
E2E/E2EQ NEXT Series  
(Double distance/Single distance/Spatter-resistant, Double distance/Single distance model)  
DC 3-Wire  
Connector Models  
(M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector)  
Shielded/Unshielded  
Pre-wired Model/Pre-wired Connector Model  
Shielded/Unshielded  
B
B
D
C
D
Indicators  
F
H
G
Standard I/O mode (SIO mode):  
Operation indicator (orange/ON),  
comunication indicator (green/OFF)  
IO-Link Communication mode (COM mode):  
Operation indicator (orange/ON),  
comunication indicator  
F
E
Indicators  
I
G
H
E
Standard I/O mode (SIO mode):  
Operation indicator (orange/ON),  
comunication indicator (green/OFF)  
IO-Link Communication mode (COM mode):  
Operation indicator (orange/ON),  
comunication indicator  
I
(green/Flashing (1sec cycle)  
A
C
(green/Flashing (1sec cycle)  
J
A
J
Two clamping nuts  
Toothed washer  
Toothed washer  
Model E2E(Q)-X@8-M1;  
Shape of connection.  
Two clamping nuts  
Pre-wired Models  
Pre-wired Connector Models (M1TJ)  
(Operation mode: NO, NC Type)  
M12×P1  
Shielded  
F
G
Model  
A
B
C
D
E
H
3
3
4
4
5
I
J
*1 *2  
E2E(Q)-X@30  
X@8-M3/M5  
10  
4
Vinyl-insulated round cable with  
3 conductors  
M8, M12 size: 4-dia.  
M18, M30 size: 6-dia.  
(Conductor cross section:  
0.2 mm2 (AWG24),  
Insulator diameter: 1.05 mm),  
Standard length: 2 m  
M8XP1  
39 M8XP1 26 ---  
43 M12XP1 26 ---  
48 M12XP1 33 ---  
53 M12XP1 38 ---  
15 13  
15 13  
21 17  
29 24  
42 36  
(8)  
(Operation mode: NO, NC Type)  
10  
4
Vinyl-insulated round cable with  
3 conductors  
M8, M12 size: 4-dia.  
M18, M30 size: 6-dia.  
(Conductor cross section:  
0.2 mm2 (AWG24),  
E2E(Q)-X@8-M1 M8XP1  
(8)  
12  
4
E2E(Q)-X  
E2E(Q)-X  
E2E(Q)-X  
@
@
@
12-M1 M12XP1  
(10)  
12  
4
18-M1 M18XP1  
Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
(10)  
(Operation mode: NO+NC Type)  
12  
4
30-M1 M30XP1.5 58 M12XP1 43 ---  
(10)  
(Operation mode: NO+NC Type)  
E2E-X  
@
L8-M3/M5 M8XP1  
49 M8XP1 36 ---  
53 M12XP1 36 ---  
8
8
---  
---  
3
3
4
4
5
15 13  
15 13  
21 17  
29 24  
42 36  
Vinyl-insulated round cable with  
4 conductors  
M12 size: 4.3-dia.  
M18, M30 size: 6-dia.  
(Conductor cross section: 0.2 mm2  
(AWG24),  
Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
Vinyl-insulated round cable with  
4 conductors  
M12 size: 4.3-dia.  
M18, M30 size: 6-dia.  
(Conductor cross section: 0.2 mm2  
(AWG24),  
Insulator diameter: 1.05 mm),  
Standard length: 2 m  
E2E-X@L8-M1  
E2E-X@L12-M1  
E2E-X@L18-M1  
E2E-X@L30-M1  
M8XP1  
M12XP1 70 M12XP1 55 --- 10 ---  
M18XP1 75 M12XP1 60 --- 10 ---  
M30XP1.5  
80 M12XP1 65 --- 10 ---  
Unshielded  
Model  
Shielded  
E
*3  
G
*2  
A
B
C
D
F
H
I
J
Model  
A
B
C
D
E
F *1  
G *2  
4
H
3
4
4
5
3
4
4
5
I
J
E2E-X@  
M
@8-M3/M5 M8XP1  
39 M8XP1 26  
43 M12XP1 26  
6
6
7
8
8
---  
---  
3
3
4
4
5
3
3
4
4
15 13  
15 13  
21 17  
29 24  
42 36  
15 13  
15 13  
21 17  
29 24  
E2E(Q)-X@8  
M8XP1  
37.8 4.4 26 --- 10 (8)  
47.1 3.7 33 --- 12 (10)  
55.3 8.5 38 --- 12 (10)  
15 13  
21 17  
29 24  
42 36  
15 13  
21 17  
29 24  
42 36  
E2E-X@M@8-M1 M8XP1  
E2E(Q)-X@12 M12XP1  
E2E(Q)-X@18 M18XP1  
4
E2E-X  
E2E-X  
E2E-X  
@
@
@
M
M
M
@12-M1  
@18-M1  
@30-M1  
M12XP1 48 M12XP1 26  
10 ---  
4
M18XP1 53 M12XP1 38 10 10 ---  
M30XP1.5 58 M12XP1 43 13 10 ---  
E2E(Q)-X@30 M30XP1.5 60.3 8.3 43 --- 12 (10)  
4
E2E-X@L8  
E2E-X@L12  
E2E-X@L18  
E2E-X@L30  
M8XP1  
47.8 4.4 36 ---  
69.1 3.7 55 ---  
77.3 8.5 60 ---  
8
---  
---  
---  
---  
E2E-X@  
M
@L8-M3-M5 M8XP1  
49 M8XP1 36  
53 M12XP1 36  
6
6
7
8
8
---  
---  
E2E-X@  
M
M
@L8-M1 M8XP1  
M12XP1  
M18XP1  
10  
10  
10  
E2E-X@  
@L12-M1 M12XP1 70 M12XP1 55  
10 ---  
E2EX@  
M
@L18-M1 M18XP1 75 M12XP1 60 10 10 ---  
M30XP1.5 82.3 8.3 65 ---  
130  
(15)  
E2E-X@  
M
@L30-M1 M30XP1.5 80 M12XP1 65  
10 ---  
5
42 36  
Unshielded  
*1. If using the E2EQ, refer to ( ) dimensions.  
*2. Mounting part of sensor lock O-ring (Y92E-J  
*3. When using X30M@30, refer to (15).  
Model  
A
B
C
D
E *3  
6
F
G *2  
H
3
4
4
5
3
4
4
5
I
J
@S  
@
) ---: Out of a subject.  
E2E-X@M@8  
M8XP1  
37.8 4.4 26  
47.1 3.7 33  
55.3 8.5 38  
8
---  
15 13  
21 17  
29 24  
42 36  
15 13  
21 17  
29 24  
42 36  
E2E-X@M@12 M12XP1  
E2E-X@M@18 M18XP1  
7
10 ---  
10 ---  
10 ---  
Mounting Hole Dimensions  
Angle R of the  
Bending Wire  
10 mm  
Wire pullout position  
10  
13  
6
Sc  
E2E-X@M@30 M30XP1.5 60.3 8.3 43  
E2E-X@M@L8 M8XP1  
47.8 4.4 36  
69.1 3.7 55  
77.3 8.5 60  
8
---  
F
E2E-X  
E2E-X  
E2E-X  
@
@
@
M
M
M
@
@
@
L12 M12XP1  
7
10 ---  
10 ---  
R
Dimensions  
M8  
F (mm)  
L18 M18XP1  
10  
Dimensions Sc (mm)  
Dimensions R (mm)  
+0.5  
8.5 dia.  
L30 M30XP1.5 82.3 8.3 65 130 (15) 10 ---  
0
M8  
- (0)  
M12  
M8  
12  
+0.5  
0
M12  
M18  
M30  
12.5 dia.  
18.5 dia.  
30.5 dia.  
*1. If using the E2EQ, refer to ( ) dimensions.  
*2. Mounting part of sensor lock O-ring (Y92E-J  
*3. When using X30M@30, refer to (15).  
M12  
@S@) ---: Out of a subject.  
+0.5  
0
M18  
2.5  
M18  
18  
+0.5  
0
M30  
M30  
65  
E2E/E2EQ NEXT Series  
Accessories (Sold Separately)  
e-jig (Mounting Sleeves)  
Y92E-J12S18  
Y92E-J8S12  
35  
23.3  
28  
3
3
18  
26.8 dia.  
24  
19 dia.  
26.8 dia.  
24  
4
4
21.2 dia.  
19  
17  
M12 × 1  
Sensor lock nut  
Mounting Sleeve  
M18 × 1  
Two Mounting Sleeve  
clamping nuts  
Sensor lock nut  
Mounting Sleeve  
Two Mounting Sleeve  
clamping nuts  
M16×1  
7
0.7  
8.8  
0.7  
M20×1  
8 dia.  
A
A
12 dia.  
Section A-A  
A
A
Section A-A  
Y92E-J18S30  
Material  
Polyetheretherketone (PEEK) /  
40  
Mounting Sleeve  
5
23.2  
Polybutylene terephthalate (PBT)  
Polybutylene terephthalate (PBT)  
Polybutylene terephthalate (PBT)  
5
40 dia.  
36  
40.8 dia.  
36  
Mounting Sleeve  
clamping nut  
Sensor lock nut  
Sensor lock O-ring  
Material combining HNBR and fluororubber  
M30 × 1.5  
Sensor lock nut  
Mounting Sleeve  
Tightening Force  
Two Mounting Sleeve  
clamping nuts  
Torque  
11.9  
M30 × 1.5  
0.7  
Model  
Mounting Sleeve  
Sensor lock nut  
clamping nut  
Y92E-J8S12  
Y92E-J12S18  
Y92E-J18S30  
0.6 N·m  
1.2 N·m  
5 N·m  
0.6 N·m  
1.2 N·m  
3.5 N·m  
18 dia.  
A
A
Section A-A  
66  
Proximity Sensor  
E2E/E2EQ NEXT Series  
DC 2-wire  
Long-distance Detection Prevents  
Unexpected Facility Stoppages  
• The world's longest sensing distance*1  
Nearly double the sensing distance of previous  
• With high-brightness LED, the indicator is visible  
anywhere from 360°.  
• Only 10 Seconds*2 to Replace a Proximity Sensor  
with the "e-jig" (Mounting Sleeve).  
• Cables with enhanced oil resistance enabled 2-year  
oil resistance*3.  
• UL certification (UL60947-5-2) and CSA certification  
(CSA C22.2 UL60947-5-2-14)  
*1. Based on July 2017 OMRON investigation.  
*2. Time required to adjust the distance when installing a Sensor.  
For the most recent information on models that have been certified  
for safety standards, refer to your OMRON website.  
Based on OMRON investigation.  
*3. Refer to page 72 and 74 for details. However, E2EQ series is  
excluded.  
Be sure to read Safety Precautions on  
page 80.  
E2E/E2EQ NEXT Series Model Number Legend  
DC 2-wire  
(1)  
(2) (3)  
(4) (5) (6) (7) (8) (9) (10)  
(11)  
-
-
-
-
E2E  
X
D
No.  
(1)  
(2)  
(3)  
Classification  
Code  
Meaning  
Blank  
Without spatter-resistant coating  
With spatter-resistant coating  
Case  
Q
Sensing distance  
Shielding  
Number  
Sensing distance (Unit: mm) (R: Indication of decimal point)  
Blank  
M
Shielded Models  
Unshielded Models  
Normally open (NO)  
Normally closed (NC)  
Standard  
1
(4)  
(5)  
Operation mode  
Body size  
2
Blank  
L
Long Body  
M8  
8
Size  
12  
18  
30  
M12  
(6)  
(7)  
(Omitted for the Single  
distance type.)  
M18  
M30  
Blank  
M1TGJ  
M1TGJR  
Pre-wired Models  
Connecting method  
M12 Pre-wired Smartclick Connector Models  
M12 Pre-wired Smartclick Connector Models (Robot (bending-resistant) PVC cable)  
Blank  
T
Polarity  
(8)  
(9)  
Polarity  
No polarity  
Blank  
R
Standard PVC cable  
Cable specifications *  
Robot (bending-resistant) PVC cable  
Other than Single distance model (Pre-wired Models)  
Single distance model (Applicable only to Pre-wired Models)  
Blank  
N
(10) New model  
(11) Cable length  
Number M Cable length  
* (9) is only shown in the model number of Pre-wired Models.  
Note: 1. The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.  
Models are not available for all combinations of code numbers.  
2. Size description of the number 7 is not included in the Single-distance type.  
67  
E2E/E2EQ NEXT Series  
Ordering Information  
Sensors  
E2E NEXT Series (Triple distance model)  
DC 2-wire [Refer to Dimensions on page 82.]  
Shielded Models *1  
Model  
Size  
Connection method  
(Sensing distance)  
Polarity  
Operation mode: NO  
E2E-X3D18 2M  
Operation mode: NC  
E2E-X3D28 2M  
Yes  
No  
Pre-wired (2 m) *2 *3  
M8  
E2E-X3D18-T 2M  
E2E-X3D28-T 2M  
(3 mm)  
Yes  
No  
E2E-X3D18-M1TGJ 0.3M  
E2E-X3D18-M1TGJ-T 0.3M  
E2E-X7D112 2M  
E2E-X3D28-M1TGJ 0.3M  
E2E-X3D28-M1TGJ-T 0.3M  
E2E-X7D212 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
Yes  
No  
Pre-wired (2 m) *2 *3  
M12  
E2E-X7D112-T 2M  
E2E-X7D212-T 2M  
(7 mm)  
Yes  
No  
E2E-X7D112-M1TGJ 0.3M  
E2E-X7D112-M1TGJ-T 0.3M  
E2E-X11D118 2M  
E2E-X7D212-M1TGJ 0.3M  
E2E-X7D212-M1TGJ-T 0.3M  
E2E-X11D218 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
Yes  
No  
Pre-wired (2 m) *2 *3  
M18  
E2E-X11D118-T 2M  
E2E-X11D218-T 2M  
(11 mm)  
Yes  
No  
E2E-X11D118-M1TGJ 0.3M  
E2E-X11D118-M1TGJ-T 0.3M  
E2E-X20D130 2M  
E2E-X11D218-M1TGJ 0.3M  
E2E-X11D218-M1TGJ-T 0.3M  
E2E-X20D230 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
Yes  
No  
Pre-wired (2 m) *2 *3  
M30  
E2E-X20D130-T 2M  
E2E-X20D230-T 2M  
(20 mm)  
Yes  
No  
E2E-X20D130-M1TGJ 0.3M  
E2E-X20D130-M1TGJ-T 0.3M  
E2E-X20D230-M1TGJ 0.3M  
E2E-X20D230-M1TGJ-T 0.3M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
Unshielded Models  
Model  
Size  
Connection method  
(Sensing distance)  
Polarity  
Operation mode: NO  
E2E-X6MD18 2M  
Operation mode: NC  
E2E-X6MD28 2M  
Yes  
No  
Pre-wired (2 m) *2 *3  
M8  
E2E-X6MD18-T 2M  
E2E-X6MD28-T 2M  
(6 mm)  
Yes  
No  
E2E-X6MD18-M1TGJ 0.3M  
E2E-X6MD18-M1TGJ-T 0.3M  
E2E-X10MD112 2M  
E2E-X6MD28-M1TGJ 0.3M  
E2E-X6MD28-M1TGJ-T 0.3M  
E2E-X10MD212 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
Yes  
No  
Pre-wired (2 m) *2 *3  
M12  
E2E-X10MD112-T 2M  
E2E-X10MD212-T 2M  
(10 mm)  
Yes  
No  
E2E-X10MD112-M1TGJ 0.3M  
E2E-X10MD112-M1TGJ-T 0.3M  
E2E-X20MD1L18 2M  
E2E-X10MD212-M1TGJ 0.3M  
E2E-X10MD212-M1TGJ-T 0.3M  
E2E-X20MD2L18 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
Yes  
No  
Pre-wired (2 m) *2 *3  
M18  
E2E-X20MD1L18-T 2M  
E2E-X20MD2L18-T 2M  
(20 mm)  
Yes  
No  
E2E-X20MD1L18-M1TGJ 0.3M  
E2E-X20MD1L18-M1TGJ-T 0.3M  
E2E-X40MD1L30 2M  
E2E-X20MD2L18-M1TGJ 0.3M  
E2E-X20MD2L18-M1TGJ-T 0.3M  
E2E-X40MD2L30 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
Yes  
No  
Pre-wired (2 m) *2 *3  
M30  
E2E-X40MD1L30-T 2M  
E2E-X40MD2L30-T 2M  
(40 mm)  
Yes  
No  
E2E-X40MD1L30-M1TGJ 0.3M  
E2E-X40MD1L30-M1TGJ-T 0.3M  
E2E-X40MD2L30-M1TGJ 0.3M  
E2E-X40MD2L30-M1TGJ-T 0.3M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 81.  
*2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2E-X3D18 5M)  
*3. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X3D18-R 2M/E2E-  
X3D18-R 5M)  
*4. Models with M12 Pre-wired Smartclick Connectors and robot (bending-resistant) cables are also available with "R" in the model number.  
(Example: E2E-X3D18-M1TGJR 0.3M/E2E-X3D18-M1TGJR-T 0.3M)  
68  
E2E/E2EQ NEXT Series  
Sensors  
E2EQ NEXT Series (Spatter-resistant Triple distance model)  
DC 2-wire [Refer to Dimensions on page 84.]  
Shielded Models *1  
Model  
Size  
Connection method  
Polarity  
(Sensing distance)  
Operation mode: NO  
E2EQ-X3D18 2M  
Operation mode: NC  
Yes  
No  
E2EQ-X3D28 2M  
Pre-wired (2 m) *2  
E2EQ-X3D18-T 2M  
E2EQ-X3D28-T 2M  
M8  
(3 mm)  
Yes  
No  
E2EQ-X3D18-M1TGJ 0.3M  
E2EQ-X3D18-M1TGJ-T 0.3M  
E2EQ-X7D112 2M  
E2EQ-X3D28-M1TGJ 0.3M  
E2EQ-X3D28-M1TGJ-T 0.3M  
E2EQ-X7D212 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m)  
Yes  
No  
Pre-wired (2 m) *2  
E2EQ-X7D112-T 2M  
E2EQ-X7D212-T 2M  
M12  
(7 mm)  
Yes  
No  
E2EQ-X7D112-M1TGJ 0.3M  
E2EQ-X7D112-M1TGJ-T 0.3M  
E2EQ-X11D118 2M  
E2EQ-X7D212-M1TGJ 0.3M  
E2EQ-X7D212-M1TGJ-T 0.3M  
E2EQ-X11D218 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m)  
Yes  
No  
Pre-wired (2 m) *2  
E2EQ-X11D118-T 2M  
E2EQ-X11D218-T 2M  
M18  
(11 mm)  
Yes  
No  
E2EQ-X11D118-M1TGJ 0.3M  
E2EQ-X11D118-M1TGJ-T 0.3M  
E2EQ-X20D130 2M  
E2EQ-X11D218-M1TGJ 0.3M  
E2EQ-X11D218-M1TGJ-T 0.3M  
E2EQ-X20D230 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m)  
Yes  
No  
Pre-wired (2 m) *2  
E2EQ-X20D130-T 2M  
E2EQ-X20D230-T 2M  
M30  
(20 mm)  
Yes  
No  
E2EQ-X20D130-M1TGJ 0.3M  
E2EQ-X20D130-M1TGJ-T 0.3M  
E2EQ-X20D230-M1TGJ 0.3M  
E2EQ-X20D230-M1TGJ-T 0.3M  
M12 Pre-wired  
Smartclick Connector (0.3 m)  
*1. When embedding the Proximity Sensor in metal, refer to Influence of Surrounding Metal on page 81.  
*2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EQ-X3D18 5M)  
E2E NEXT Series (Single distance model)  
DC 2-wire [Refer to Dimensions on page 85.]  
Shielded Models  
Model  
Size  
Connection method  
Polarity  
(Sensing distance)  
Operation mode: NO  
E2E-X1R5D1-N 2M  
Operation mode: NC  
E2E-X1R5D2-N 2M  
Yes  
No  
Pre-wired (2 m) *2 *3  
E2E-X1R5D1-T-N 2M  
E2E-X1R5D2-T-N 2M  
M8  
(1.5 mm)  
Yes  
No  
E2E-X1R5D1-M1TGJ 0.3M  
E2E-X1R5D1-M1TGJ-T 0.3M  
E2E-X2R5D1-N 2M  
E2E-X1R5D2-M1TGJ 0.3M  
E2E-X1R5D2-M1TGJ-T 0.3M  
E2E-X2R5D2-N 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
Yes  
No  
Pre-wired (2 m) *2 *3  
E2E-X2R5D1-T-N 2M  
E2E-X2R5D2-T-N 2M  
M12  
(2.5 mm)  
Yes  
No  
E2E-X2R5D1-M1TGJ 0.3M  
E2E-X2R5D1-M1TGJ-T 0.3M  
E2E-X5D1-N 2M  
E2E-X2R5D2-M1TGJ 0.3M  
E2E-X2R5D2-M1TGJ-T 0.3M  
E2E-X5D2-N 2M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
Yes  
No  
Pre-wired (2 m) *2 *3  
E2E-X5D1-T-N 2M  
E2E-X5D2-T-N 2M  
M18  
(5 mm)  
Yes  
No  
E2E-X5D1-M1TGJ 0.3M  
E2E-X5D1-M1TGJ-T 0.3M  
E2E-X5D2-M1TGJ 0.3M  
E2E-X5D2-M1TGJ-T 0.3M  
M12 Pre-wired  
Smartclick Connector (0.3 m) *4  
*1. Models with 5-m cable length are also available with "5M" suffix. (Example: E2E-X1R5D1-N 5M)  
*2. Models with 2-m and 5-m robot (bending-resistant) cables are also available with "-R" in the model number. (Example: E2E-X1R5D1-R-N 2M/  
E2E-X1R5D1-R-N 5M)  
*3. Models with M12 Smartclick connector model robot (bending-resistant) cables are also available with "R" in the model number. (Example: E2E-  
X1R5D1-M1TGJR 0.3M/E2E-X1R5D1-M1TGJR-T 0.3M)  
69  
E2E/E2EQ NEXT Series  
Accessories (Sold Separately)  
Sensor I/O Connectors  
(Models for Pre-wired Connectors) A Sensor I/O Connector is not provided with the Sensor. It must be ordered separately as required.  
Round Oil-resistant Connectors XS5 NEXT series  
Cable  
diameter  
(mm)  
Cable  
length  
(m)  
Cable  
Specification  
Cable Connection  
Direction  
Sensor I/O Connector  
model number  
Applicable Proximity  
Sensor model number  
Appearance  
Type  
1
2
XS5F-D421-C80-X  
XS5F-D421-D80-X  
XS5F-D421-E80-X  
XS5F-D421-G80-X  
XS5F-D421-J80-X  
XS5F-D421-C80-XR  
XS5F-D421-D80-XR  
XS5F-D421-E80-XR  
XS5F-D421-G80-XR  
XS5F-D421-J80-XR  
XS5W-D421-C81-X  
XS5W-D421-D81-X  
XS5W-D421-E81-X  
XS5W-D421-G81-X  
XS5W-D421-J81-X  
XS5W-D421-C81-XR  
XS5W-D421-D81-XR  
XS5W-D421-E81-XR  
XS5W-D421-G81-XR  
XS5W-D421-J81-XR  
Oil-resistant  
PVC cable  
Sockets on One  
Cable End  
6 dia.  
6 dia.  
6 dia.  
6 dia.  
Straight  
Straight  
3
5
10  
1
M12  
Smartclick  
Connector  
2
Oil-resistant  
PVC robot cable Cable End  
Sockets on One  
3
5
Straight type  
10  
1
E2E-X@D@-M1TGJ(R)(-T)  
E2EQ-X@D@-M1TGJ(-T)  
2
Oil-resistant  
PVC cable  
Socket and Plug  
on Cable Ends  
Straight (Socket)/  
Straight (Plug)  
3
5
10  
1
2
Oil-resistant  
PVC robot cable on Cable Ends  
Socket and Plug  
Straight (Socket)/  
Straight (Plug)  
3
5
10  
Note: For details of the connector, refer to XS5 NEXT Series on page 87.  
Round Water-resistant Connectors XS5 series  
Cable  
diameter  
(mm)  
Cable  
length  
(m)  
Cable  
Specification  
Cable Connection  
Direction  
Sensor I/O Connector  
model number  
Applicable Proximity  
Sensor model number  
Appearance  
Type  
1
2
XS5F-D421-C80-F  
XS5F-D421-D80-F  
XS5F-D421-E80-F  
XS5F-D421-G80-F  
XS5F-D421-J80-F  
XS5F-D422-C80-F  
XS5F-D422-D80-F  
XS5F-D422-E80-F  
XS5F-D422-G80-F  
XS5F-D422-J80-F  
XS5W-D421-C81-F  
XS5W-D421-D81-F  
XS5W-D421-E81-F  
XS5W-D421-G81-F  
XS5W-D421-J81-F  
XS5W-D422-D81-F  
XS5W-D422-G81-F  
Straight  
3
5
10  
1
Sockets on One  
Cable End  
M12  
Smartclick  
Connector  
6 dia.  
2
Right-angle  
3
Straight type  
5
10  
1
E2E-X@D@-M1TGJ(R)(-T)  
E2EQ-X@D@-M1TGJ(-T)  
PVC robot cable  
2
Straight (Socket)/  
Straight (Plug)  
3
5
Right-angle type  
10  
2
Socket and Plug  
on Cable Ends  
Right-angle (Socket)/  
Right-angle (Plug)  
6 dia.  
5
2
5
2
5
XS5W-D423-D81-F  
XS5W-D423-G81-F  
XS5W-D424-D81-F  
XS5W-D424-G81-F  
Straight (Socket)/  
Right-angle (Plug)  
Right-angle (Socket)/  
Straight (Plug)  
Note: For details of the connector, refer to XS5 Series on page 94.  
70  
E2E/E2EQ NEXT Series  
Sensor I/O Connectors Oil resistance performance of mating combination  
Applicable connector Model  
E2E NEXT Series  
Pre-wired Connector Models  
XS5 NEXT series  
2 years of oil resistance*  
XS5 series  
E2E-X@D@-M1TGJ(R)(-T)  
Water-resistant (IP67)  
* Applicable cutting oil type: specified in JIS K 2241:2000  
2 years of oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).  
Products to be shipped will have around 2 years of oil resistance, but will very depending on the product.  
e-jig (Mounting Sleeves) [Refer to Dimensions on page 86.]  
A Mounting Bracket is not provided with the Sensor. It must be ordered separately as required.  
Appearance  
Model  
Y92E-J8S12  
Applicable Sensors  
E2E NEXT M8 Shielded Sensors  
E2E NEXT M12 Shielded Sensors  
E2E NEXT M18 Shielded Sensors  
Y92E-J12S18  
Y92E-J18S30  
Note: Not applicable for E2EQ NEXT Series (spatter-resistant) models.  
71  
E2E/E2EQ NEXT Series  
Ratings and Specifications  
E2E NEXT Series (Triple distance model)  
DC 2-wire  
Size  
Shielded  
Model  
M8  
M12  
M18  
M30  
Shielded  
E2E-X3D@  
3 mm ±10%  
0 to 2.4 mm  
Unshielded  
Shielded  
E2E-X7D@  
7 mm ±10%  
0 to 5.6 mm  
Unshielded  
Shielded  
Unshielded  
Shielded  
Unshielded  
Item  
E2E-X6MD@  
E2E-X10MD@ E2E-X11D@ E2E-X20MD@ E2E-X20D@ E2E-X40MD@  
Sensing distance  
6 mm ±10%  
0 to 4.8 mm  
10 mm ±10%  
0 to 8 mm  
11 mm ±10%  
0 to 8.8 mm  
20 mm ±10%  
0 to 16 mm  
20 mm ±10%  
0 to 16 mm  
40 mm ±10%  
0 to 32 mm  
Setting distance *1  
Differential travel  
Detectable object  
15% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 75.)  
Iron,  
9 × 9 × 1 mm  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
Iron,  
Standard sensing object  
18 × 18 × 1 mm 21 × 21 × 1 mm 30 × 30 × 1 mm 33 × 33 × 1 mm 60 × 60 × 1 mm 60 × 60 × 1 mm 120 × 120 × 1 mm  
Response frequency *2  
Power supply voltage  
Leakage current  
350 Hz  
250 Hz 350 Hz 200 Hz 250 Hz 200 Hz 200 Hz 50 Hz  
10 to 30 VDC, (including 10% ripple (p-p))  
0.8 mA max.  
Load current  
Control  
3 to 100 mA  
Residual  
output  
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)  
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m)  
voltage  
D1 Models: Operation indicator (orange), Setting indicator (green)  
D2 Models: Operation indicator (orange)  
Indicator  
D1 Models: NO  
D2 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on page 78 for details.  
Operation mode  
Protection circuits  
Surge suppressor, Load short-circuit protection  
Ambient temperature  
range  
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)  
Operating and Storage: 35% to 95% (with no condensation)  
Ambient humidity range  
±20% max. of ±10% max. of  
sensing  
sensing  
distance at  
23°C in the  
temperature  
range of  
distance at  
23°C in the  
temperature  
range of  
±20% max. of sensing distance  
at 23°C in the temperature  
range of -25 to 70°C  
±10% max. of sensing distance at 23°C  
in the temperature range of -25 to 70°C  
Temperature influence  
-25 to 70°C  
-25 to 70°C  
Voltage influence  
Insulation resistance  
Dielectric strength  
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
Vibration resistance  
(destruction)  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Shock resistance  
(destruction)  
500 m/s2 10 times each in X, Y,  
1,000 m/s2 10 times each in X, Y, and Z directions  
and Z directions  
Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant  
Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35 °C max.) and ISO 20653 (old  
standard: DIN 40050 PART9) IP69K  
Degree of protection  
Connecting method  
Pre-wired  
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m)  
Approx. 60 g  
Approx. 70 g  
Approx. 130 g Approx. 150 g Approx. 180 g Approx. 210 g  
Models  
Weight  
(packed  
state)  
Pre-wired  
Connector  
Models  
Approx. 30 g  
Approx. 40 g  
Approx. 70 g  
Approx. 90 g  
Approx.110 g Approx. 140 g  
Nickel-plated  
brass  
Stainless steel  
(SUS303)  
Case  
Nickel-plated brass  
Sensing surface Polybutylene terephthalate (PBT)  
Materials  
Clamping nuts  
Toothed washer Zinc-plated iron  
Cable Vinyl chloride (PVC)  
Accessories Instruction manual, Clamping nuts, Toothed washer  
Nickel-plated brass  
*1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).  
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard  
sensing object, and a set distance of half the sensing distance.  
*3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).  
The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.  
*4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards.  
2-year oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).  
The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round Oil-resistant Connectors XS5 NEXT series correctly.  
The degree of protection is not satisfied with the part where cable wires are uncovered for the Pre-wired Models.  
72  
E2E/E2EQ NEXT Series  
E2EQ NEXT Series (Spatter-resistant Triple distance model)  
DC 2-wire  
Size  
Shielded  
Model  
M8  
M12  
M18  
M30  
Shielded  
Item  
E2EQ-X3D@  
E2EQ-X7D@  
E2EQ-X11D@  
E2EQ-X20D@  
Sensing distance  
Setting distance *1  
Differential travel  
Detectable object  
Standard sensing object  
Response frequency *2  
Power supply voltage  
Leakage current  
3 mm ±10%  
7 mm ±10%  
0 to 5.6 mm  
11 mm ±10%  
0 to 8.8 mm  
20 mm ±10%  
0 to 16 mm  
0 to 2.4 mm  
15% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 75.)  
Iron, 9 × 9 × 1 mm  
250 Hz  
Iron, 21 × 21 × 1 mm  
250 Hz  
Iron, 33 × 33 × 1 mm  
250 Hz  
Iron, 60 × 60 × 1 mm  
200 Hz  
10 to 30 VDC, (including 10% ripple (p-p))  
0.8 mA max.  
Load current  
3 to 100 mA  
Control output  
Indicator  
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)  
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m)  
Residual voltage  
D1 Models: Operation indicator (orange), Setting indicator (green)  
D2 Models: Operation indicator (orange)  
D1 Models: NO  
D2 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on page 78 for details.  
Operation mode  
Protection circuits  
Surge suppressor, Load short-circuit protection  
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)  
Operating and Storage: 35% to 95% (with no condensation)  
Ambient temperature range  
Ambient humidity range  
±10% max. of sensing distance at 23°C  
in the temperature range of -25 to 70°C  
±20% max. of sensing distance at 23°C  
in the temperature range of -25 to 70°C  
Temperature influence  
Voltage influence  
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
Insulation resistance  
Dielectric strength  
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
Vibration resistance (destruction)  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
500 m/s2 10 times each in  
Shock resistance (destruction)  
1,000 m/s2 10 times each in X, Y, and Z directions  
X, Y, and Z directions  
Degree of protection  
Connecting method  
Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529) and IP67G *3 (JIS C 0920 Annex 1)  
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m)  
Pre-wired Models  
Approx. 60 g  
Approx. 70 g  
Approx. 150 g  
Approx. 210 g  
Weight  
(packed state)  
Pre-wired Connector  
Models  
Approx. 30 g  
Approx. 40 g  
Approx. 90 g  
Approx. 140 g  
Case  
Fluororesin coating (Base material: brass)  
Fluororesin  
Sensing surface  
Clamping nuts  
Toothed washer  
Cable  
Materials  
Fluororesin coating (Base material: brass)  
Zinc-plated iron  
Vinyl chloride (PVC)  
Accessories  
Instruction manual, Clamping nuts, Toothed washer  
*1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).  
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard  
sensing object, and a set distance of half the sensing distance.  
*3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).  
The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.  
73  
E2E/E2EQ NEXT Series  
E2E NEXT Series (Single distance model)  
DC 2-wire  
Size  
M8  
M12  
M18  
Shielded  
Shielded  
Item  
Model  
E2E-X1R5D@  
E2E-X2R5D@  
E2E-X5D@  
Sensing distance  
Setting distance *1  
Differential travel  
Detectable object  
Standard sensing object  
Response frequency *2  
Power supply voltage  
Leakage current  
1.5 mm ±10%  
2.5 mm ±10%  
0 to 2 mm  
5 mm ±10%  
0 to 4 mm  
0 to 1.2 mm  
10% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 75.)  
Iron, 10 × 10 × 1 mm  
250 Hz  
Iron, 12 × 12 × 1 mm  
250 Hz  
Iron, 18 × 18 × 1 mm  
250 Hz  
10 to 30 VDC, (including 10% ripple (p-p))  
0.8 mA max.  
Load current  
3 to 100 mA  
Control output  
Indicator  
Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m)  
No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m)  
Residual voltage  
D1 Models: Operation indicator (orange), Setting indicator (green)  
D2 Models: Operation indicator (orange)  
D1 Models: NO  
D2 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on page 78 for details.  
Operation mode  
Protection circuits  
Surge suppressor, Load short-circuit protection  
Ambient temperature range  
Ambient humidity range  
Temperature influence  
Voltage influence  
Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation)  
Operating and Storage: 35% to 95% (with no condensation)  
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C  
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case  
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Insulation resistance  
Dielectric strength  
Vibration resistance (destruction)  
500 m/s2 10 times each in X, Y, and Z  
1,000 m/s2 10 times each in X, Y, and Z directions  
directions  
Shock resistance (destruction)  
Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's  
Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C  
max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K  
Degree of protection  
Connecting method  
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m)  
Pre-wired Models  
Weight  
(packed state)  
Approx. 60 g  
Approx. 70 g  
Approx. 130 g  
Pre-wired Connector  
Models  
Approx. 30 g  
Approx. 40 g  
Approx. 70 g  
Case  
Stainless steel (SUS303)  
Polybutylene terephthalate (PBT)  
Nickel-plated brass  
Nickel-plated brass  
Sensing surface  
Clamping nuts  
Toothed washer  
Cable  
Materials  
Zinc-plated iron  
Vinyl chloride (PVC)  
Accessories  
Instruction manual, Clamping nuts, Toothed washer  
*1. Use the Sensor within the range in which the setting indicator (green LED) is ON (except D2 Models).  
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the  
standard.  
*3. The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).  
The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil.  
*4. The Oil-resistant Component Evaluation Standards are OMRON's own durability evaluation standards.  
2-year oil resistance indicates the median value of the product design and the oil-resistance performance criterion result (=Typical value).  
The Pre-wired Connector Model verifies 2 years of oil resistance when mating with Round Oil-resistant Connectors XS5 NEXT series correctly.  
The degree of protection is not satisfied with the part where cable wires are uncovered for the Pre-wired Models.  
74  
E2E/E2EQ NEXT Series  
Engineering Data (Reference Value)  
Sensing Area  
Triple distance model, Spatter-resistant Triple distance model  
Shielded Models  
Unshielded Models  
E2E(Q)-X@D@  
E2E-X@MD@  
20  
40  
Y
E2E(Q)-X20D@30  
E2E-X40MD@L30  
X
35  
Y
X
15  
30  
25  
E2E(Q)-X11D@18  
E2E-X20MD@L18  
10  
5
20  
15  
10  
5
E2E(Q)-X7D@12  
E2E-X10MD@12  
E2E(Q)-X3D@8  
E2E-X6MD@8  
0
-15  
0
-30  
-10  
-5  
0
5
10  
15  
-20  
-10  
0
10  
20  
30  
Distance Y (mm)  
Distance Y (mm)  
Single distance model  
Shielded Models  
E2E-X1R5D@/-X2R5D@/-X5D@  
6
Y
E2E-X5D@  
X
5
4
E2E-X2R5D@  
3
2
1
0
E2E-X1R5D@  
-10  
-5  
0
5
10  
Distance Y (mm)  
75  
E2E/E2EQ NEXT Series  
Influence of Sensing Object Size and Materials  
Triple distance model, Spatter-resistant Triple distance model  
Single distance model  
Shielded Models  
E2E-X1R5D@  
Shielded Models  
E2E(Q)-X3D@8  
3 5  
Unshielded Models  
E2E-X6MD@8  
7
2.5  
@d  
@d  
@d  
t =1 mm  
Iron  
t =1 mm  
t =1 mm  
X
6
5
4
3
2
1
0
X
3 0  
X
Iron  
2.0  
2 5  
2 0  
1 5  
1 0  
0 5  
0 0  
Iron  
Stainless steel  
(SUS304)  
1.5  
1.0  
0.5  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Brass  
Brass  
Aluminum  
Brass  
Aluminum  
Copper  
Copper  
Aluminum  
20  
0
5
10  
15  
25  
0
5
10  
15  
20  
25  
30  
35  
0
5
10  
15  
20  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
E2E(Q)-X7D@12  
E2E-X10MD@12  
E2E-X2R5D@  
12  
8
3.0  
@d  
@
d
@d  
t =1 mm  
Iron  
t =1 mm  
t =1 mm  
Iron  
X
X
7
6
5
4
3
2
1
0
Iron  
X
10  
8
2.5  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
2.0  
1.5  
1.0  
0.5  
Stainless steel  
(SUS304)  
6
Brass  
Brass  
Brass  
4
Aluminum  
Copper  
Aluminum  
Copper  
Aluminum  
2
0
0
10  
20  
30  
40  
50  
60  
0
5
10  
15  
20  
25  
30  
0
10  
20  
30  
40  
50  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
E2E(Q)-X11D@18  
E2E-X20MD@L18  
E2E-X5D@  
12  
25  
7
Iron  
t =1 mm  
@d  
@d  
@d  
t =1 mm  
t =1 mm  
X
X
6
5
4
3
2
1
X
10  
8
Iron  
20  
15  
10  
5
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
6
Brass  
Aluminum  
Copper  
Brass  
Brass  
4
Aluminum  
Copper  
Aluminum  
2
0
0
0
10  
20  
30  
40  
50  
0
20  
40  
60  
80  
100  
0
10  
20  
30  
40  
50  
60  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
E2E(Q)-X20D@30  
E2E-X40MD@L30  
45  
25  
@d  
Iron  
@d  
t =1 mm  
40  
t =1 mm  
X
X
Iron  
20  
15  
10  
5
35  
30  
25  
20  
15  
10  
5
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Brass  
Brass  
Aluminum  
Copper  
Aluminum  
Copper  
0
0
0
20  
40  
60  
80  
100  
0
50  
100  
150  
200  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
76  
E2E/E2EQ NEXT Series  
Leakage Current  
Triple distance model, Spatter-resistant Triple distance model, Single distance model  
E2E-X@(M)D@(-T)/E2EQ-X@D@(-T)  
1.0  
0.8  
0.6  
0.4  
0.2  
0
5
10  
15  
20  
25  
30  
Power supply voltage (V)  
Residual Output Voltage  
Triple distance model, Spatter-resistant Triple distance model, Single distance model  
E2E-X@(M)D@(-T)/E2EQ-X@D@(-T)  
5
4
E2E-X@(M)D@-T/  
E2EQ-X@D@-T  
3
E2E-X@(M)D@/  
E2EQ-X@D@  
2
1
0
1
10  
100  
Load current (mA)  
77  
E2E/E2EQ NEXT Series  
I/O Circuit Diagrams  
DC 2-Wire Models  
Operation  
Model  
Timing Chart  
Output circuit  
mode  
Brown  
Connector Pin  
Arrangement  
Load  
1
10 to 30 VDC  
Set position  
Proximity  
sensor  
main  
Non-  
sensing  
area  
Unstable  
sensing  
area  
Stable  
sensing area  
E2E(Q)-X@D1@  
Proximity  
Sensor  
circuit  
Blue  
4
Sensing  
object  
Note: Pins 2 and 3  
are not used.  
0 V  
Note: The load can be connected to either the +V or 0 V side.  
(%)  
100 80  
0
Rated  
sensing  
distance  
NO  
Brown  
Connector Pin  
Arrangement  
Setting  
indicator  
(green)  
ON  
4
3
Load  
OFF  
10 to 30 VDC (0V)  
Proximity  
sensor  
main  
Operation  
indicator  
(orange)  
ON  
circuit  
OFF  
E2E(Q)-X@D1@-T  
E2E(Q)-X@D2@  
E2E(Q)-X@D2@-T  
Blue  
0V (10 to 30 VDC)  
Note: Pins 1 and 2  
are not used.  
ON  
Control  
output  
OFF  
Note1. The load can be connected to either the +V or 0 V side.  
2. The E2E@-X@D1@(-M1TGJ)-T has no polarity. There is no need to be  
concerned about the polarity of brown and blue wires, or pins 3 and 4.  
Brown  
Connector Pin  
Arrangement  
Load  
1
10 to 30 VDC  
Proximity  
sensor  
main  
Non-sensing  
area  
Sensing area  
Proximity  
Sensor  
circuit  
Blue  
2
Sensing  
object  
Note: Pins 3 and 4  
are not used.  
0 V  
Note: The load can be connected to either the +V or 0 V side.  
100  
0
(%)  
Brown  
NC  
Connector Pin  
Arrangement  
Rated  
sensing  
distance  
1
2
Load  
10 to 30 VDC (0V)  
Proximity  
sensor  
main  
Operation  
indicator  
(orange)  
ON  
OFF  
circuit  
ON  
Control  
output  
Blue  
0V (10 to 30 VDC)  
OFF  
Note: Pins 3 and 4  
are not used.  
Note1. The load can be connected to either the +V or 0 V side.  
2. The E2E@-X@D1@(-M1TGJ)-T has no polarity. There is no need to be  
concerned about the polarity of brown and blue wires, or pins 1 and 2.  
78  
E2E/E2EQ NEXT Series  
Connections to Sensor I/O Connectors  
Proximity Sensor  
Sensor I/O Connector  
Connections  
Operation  
mode  
model number  
Type  
Polarity  
Model  
E2E/E2EQ NEXT Series  
XS5  
*
1
2
3
4
1
2
3
4
Brown (+)  
E2E-X@D1@-M1TGJ  
E2EQ-X@D1@-M1TGJ  
White (not connected)  
Blue (not connected)  
Black ()  
Yes  
NO  
NC  
NO  
NC  
E2E/E2EQ NEXT Series  
XS5  
XS5F-D421-@80-X@  
XS5F-D42@-@80-F  
XS5W-D421-@81-X@  
XS5W-D42@-@81-F  
*
1
2
3
4
1
2
3
4
Brown (+)  
E2E-X@D2@-M1TGJ  
E2EQ-X@D2@-M1TGJ  
No  
White ()  
Blue (not connected)  
Black (not connected)  
DC 2-wire  
(Smartclick  
Connector)  
Note: For details of the  
connector, refer to  
XS5 NEXT Series on  
page 87.  
E2E/E2EQ NEXT Series  
XS5F  
*
Brown (not connected)  
1
2
3
4
1
2
3
4
E2E-X@D1@-M1TGJ-T  
E2EQ-X@D1@-M1TGJ-T  
Yes  
No  
White (not connected)  
XS5 Series on  
page 94.  
Blue (+) ()  
Black () (+)  
E2E/E2EQ NEXT Series  
XS5F  
*
1
2
3
4
1
2
3
4
Brown (+)()  
E2E-X@D2@-M1TGJ-T  
E2EQ-X@D2@-M1TGJ-T  
White ()(+)  
Blue (not connected)  
Black (not connected)  
Note: Different from Proximity Sensor wire colors.  
* If the XS5W Series Connector which has a socket and plug on the cable ends is connected to the Sensor, this part will be a plug.  
79  
E2E/E2EQ NEXT Series  
Safety Precautions  
Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/.  
Warning Indications  
Precautions for Safe Use  
The following precautions must be observed to ensure safe operation.  
Warning level  
Indicates a potentially hazardous situation  
1. Do not use the product in an environment where flammable or  
which, if not avoided, will result in minor or  
moderate injury, or may result in serious  
injury or death. Additionally there may be  
explosive gas is present.  
WARNING  
2. Do not attempt to disassemble, repair, or modify the product.  
3. Do not use a voltage that exceeds the rated operating voltage  
significant property damage.  
range. Applying a voltage that is higher than the operating voltage  
range may result in damage or burnout.  
4. Be sure that the power supply polarity and other wiring is correct.  
Incorrect wiring may cause explosion or burnout.  
5. If the power supply is connected directly without a load, the  
internal elements may explode or burn. Be sure to insert a load  
when connecting the power supply.  
Precautions for  
Supplementary comments on what to do or  
avoid doing, to use the product safely.  
Safe Use  
Supplementary comments on what to do or  
avoid doing, to prevent failure to operate,  
malfunction or undesirable effect on  
product performance.  
Precautions for  
Correct Use  
6. Dispose of this product as industrial waste.  
Meaning of Product Safety Symbols  
Precautions for Correct Use  
General prohibition  
Do not use this product under ambient conditions that exceed the  
ratings.  
Operating Environment  
Indicates the instructions of unspecified  
prohibited action.  
1. Do not install the product in the following locations.  
Doing so may result in product failure or malfunction.  
(1) Outdoor locations directly subject to sunlight, rain, snow, water  
droplets, or oil.  
Caution, explosion  
Indicates the possibility of explosion under  
specific conditions.  
(2) Locations subject to atmospheres with chemical vapors, in  
particular solvents and acids.  
(3) Locations subject to corrosive gases.  
WARNING  
2. The Sensor may malfunction if used near ultrasonic cleaning  
equipment, high-frequency equipment, transceivers, cellular  
phones, inverters, or other devices that generate a high-frequency  
electric field. Please refer to the Precautions for Correct Use on  
the OMRON website (www.ia.omron.com) for typical measures.  
3. Laying the Proximity Sensor wiring in the same conduit or duct as  
high-voltage wires or power lines may result in incorrect operation  
and damage due to induction. Wire the Sensor using a separate  
conduit or independent conduit.  
This product is not designed or rated for ensuring  
safety of persons either directly or indirectly.  
Do not use it for such purposes.  
Risk of explosion.  
Do not connect sensor to AC power supply.  
4. Never use thinner or other solvents. Otherwise, the Sensor  
surface may be dissolved.  
5. The following conditions shall be observed if you use the product  
under an environment using cutting oil that may affect product’s  
life and/or performance.  
• Usage under the cutting oil condition designated by the  
specification  
• Usage under the cutting oil dilution ratio recommended by its  
manufacturer  
• Usage in oil or water is prohibited  
Impact on the product life may differ depending on the oil you use.  
Before using the cutting oil, make sure that it should not cause  
deterioration or degradation of sealing components.  
80  
E2E/E2EQ NEXT Series  
Design  
Mutual Interference  
When the Proximity Sensor is embedded in metal, ensure that the  
minimum distances given in the following table are maintained.  
Influence of Surrounding Metal  
When mounting the Proximity Sensor using a nut, only use the  
provided nut. And ensure that the minimum distances given in the  
following table are maintained.  
L
L
B
A
(Unit: mm)  
n
d dia.  
m
Type  
Item  
M8  
25  
M12 M18 M30  
D
m
Triple distance model/  
Spatter-resistant Triple  
distance model  
A
40  
30  
70  
45  
140  
70  
*3  
Shielded  
(Unit: mm)  
B
20  
E2E(Q)-X@D@(-T)  
Type  
Item  
L
M8  
M12 M18 M30  
A
B
A
B
80  
60  
20  
15  
120  
100  
30  
200  
120  
50  
380  
280  
Triple distance model  
E2E-X@MD@(-T)  
0
0
20  
4
0
50  
4
0
70  
8
Unshielded  
Shielded  
Triple distance model/  
Spatter-resistant Triple  
distance model  
E2E(Q)-X@D@(-T)  
*1  
d
20  
2
Single distance model  
E2E-X@R5D@(-T)  
E2E-X5D@(-T)  
Shielded  
D
m
n
---  
9
18  
20  
16  
50  
20  
30  
50  
33  
54  
60  
90  
20  
35  
18  
10  
30  
13  
18  
30  
L
31 50 *3  
Mounting  
Tightening Force  
d
90  
35  
60  
80  
170  
55  
Triple distance model  
E2E-X@MD@(-T)  
*2  
Unshielded  
Shielded  
D
m
n
Do not tighten the nut with excessive force.  
A washer must be used with the nut.  
120  
140  
Shielded Models  
Unshielded Models  
L
0
0
0
d
D
m
n
8
0
12  
0
18  
0
Single distance model  
E2E-X@R5D@(-T)  
E2E-X5D@(-T)  
*2  
---  
Part B Part A  
Part B Part A  
4.5  
12  
8
20  
27  
Note: 1. The allowable tightening strength depends on the distance  
from the edge of the head, as shown in the following table. (A  
is the distance from the edge of the head. B includes the nut on  
the head side. If the edge of the nut is in part A, the tightening  
torque for part A applies instead.)  
18  
Note: Nuts that are supplied along with each Sensor (*1, *2) are  
different. Refer to Dimensions for details on shapes.  
*3. If you use the M30 Triple distance model of Unshielded Model, the  
panel thickness (t) is 4 mm or less.  
2. The following strengths assume washers are being used.  
Triple distance model  
When the Proximity Sensor is mounted in metal, ensure that the  
minimum distances given in the following table are maintained.  
Part A  
Dimension(mm)  
Part B  
Model  
Torque  
Torque  
I
Shielded  
9
3
M8  
4 N·m  
10 N·m  
15 N·m  
60 N·m  
80 N·m  
Unshielded  
Shielded  
16  
9
n
m
M12  
M18  
M30  
6 N·m  
15 N·m  
40 N·m  
d dia.  
Unshielded  
Shielded  
D
16  
3
m
I
Unshielded  
Shielded  
(Unit: mm)  
23  
8
Type  
Item  
I
M8  
M12 M18 M30  
Unshielded  
2
4
20  
4
4
50  
4
8
70  
Spatter-resistant Triple distance model  
Triple distance model/  
Spatter-resistant Triple  
distance model  
d
20  
2
Part A  
Model  
Part B  
Torque  
10 N·m  
15 N·m  
30 N·m  
80 N·m  
Shielded  
D
m
n
8
Dimension(mm)  
Torque  
4 N·m  
9
18  
20  
20  
50  
20  
30  
50  
33  
54  
35  
90  
35  
60  
80  
60  
E2E(Q)-X@D@(-T)  
M8  
9
18  
13  
30  
13  
18  
30  
90  
M12  
M18  
M30  
16  
16  
23  
6 N·m  
I
55  
d
170  
55  
15 N·m  
40 N·m  
Triple distance model  
E2E-X@MD@(-T)  
Unshielded  
D
m
n
120  
140  
Single distance model  
Part A  
Dimension(mm)  
Part B  
Torque  
12 N·m  
I
0
0
0
Model  
Torque  
d
8
0
12  
0
18  
0
Single distance model  
E2E-X@R5D@(-T)  
E2E-X5D@(-T)  
M8  
9
9 N·m  
Shielded  
D
m
n
---  
M12  
M18  
30 N·m  
70 N·m  
---  
4.5  
12  
8
20  
27  
18  
81  
E2E/E2EQ NEXT Series  
Dimensions  
(Unit: mm)  
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.  
Sensors  
E2E NEXT Series (Triple distance model)  
DC 2-wire  
Pre-wired Models  
Shielded  
Pre-wired Models  
Unshielded  
E2E-X3D@8  
E2E-X6MD@8  
37.8  
37.8  
4.4  
4.4  
33.4  
33.4  
15 dia.  
15 dia.  
6
20  
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 2 m  
26  
3
8
4
10  
13  
13  
4
1
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 2 m  
Indicators *  
Two clamping nuts  
Toothed washer  
Indicators *  
Two clamping nuts  
Toothed washer  
M8 × P1  
M8 × P1  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
E2E-X10MD@12  
E2E-X7D@12  
47.1  
47.1  
3.7  
3.7  
43.4  
21 dia.  
43.4  
21 dia.  
17  
33  
33  
17  
7
4-dia. vinyl-insulated round cable with  
12  
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 2 m  
26  
5.5  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 2 m  
4
10  
4
1
Indicators *  
Two clamping nuts  
Indicators *  
M12 × P1  
M12 × P1  
Two clamping nuts  
Toothed washer  
Toothed washer  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
E2E-X11D@18  
E2E-X20MD@L18  
77.3  
68.8  
55.3  
46.8  
8.5  
8.5  
60  
29 dia.  
24  
38  
29 dia.  
13  
47  
6-dia. vinyl-insulated round cable  
6-dia. vinyl-insulated round cable  
6
12  
with 2 conductors (Conductor cross  
24  
4
with 2 conductors (Conductor cross  
section: AWG20, Insulator diameter:  
1.5 mm), Standard length: 2 m  
12  
4
1
section: AWG20, Insulator diameter:  
1.5 mm), Standard length: 2 m  
Indicators *  
M18 × P1  
Toothed washer  
Indicators *  
Two clamping nuts  
D1 Models: Operation indicator (Orange), Setting indicator (Green)  
Two clamping nuts  
Toothed washer  
M18 × P1  
*
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
D2 Models: Operation indicator (Orange)  
E2E-X40MD@L30  
E2E-X20D@30  
60.3  
82.3  
8.3  
8.3  
52  
74  
65  
43  
42 dia.  
36  
42 dia.  
36  
15  
50  
7
6-dia. vinyl-insulated round cable  
with 2 conductors (Conductor cross  
section: AWG20, Insulator diameter:  
1.5 mm), Standard length: 2 m  
12  
6-dia. vinyl-insulated round cable  
with 2 conductors (Conductor cross  
section: AWG20, Insulator diameter:  
1.5 mm), Standard length: 2 m  
5
10  
4
1
Indicators *  
Two clamping nuts  
Toothed washer  
Indicators *  
Two clamping nuts  
Toothed washer  
M30 × P1.5  
M30 × P1.5  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
Mounting Hole Dimensions  
Angle R of the Bending Wire  
Wire pullout position  
Sc  
10 mm  
R
(mm)  
Sc  
(mm)  
Dimensions  
M8  
F (mm)  
Dimensions  
Dimensions  
+0.5  
0
8.5 dia.  
12.5 dia.  
18.5 dia.  
30.5 dia.  
M8  
M8  
+0.5  
0
12  
- (0)  
M12  
M12  
M12  
M18  
M30  
+0.5  
0
R
M18  
F
M18  
+0.5  
0
18  
2.5  
M30  
M30  
82  
E2E/E2EQ NEXT Series  
Pre-wired Connector Models  
Shielded  
Pre-wired Connector Models  
Unshielded  
E2E-X3D@8-M1TGJ  
E2E-X6MD@8-M1TGJ  
37.8  
37.8  
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
15 dia.  
4.4  
15 dia.  
13  
4.4  
33.4  
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
33.4  
26  
26  
6
13  
20  
10  
4
3
8
1
4
Indicators *  
Two clamping nuts  
Toothed washer  
Indicators *  
Two clamping nuts  
Toothed washer  
M12 × P1  
M12 × P1  
M8 × P1  
M8 × P1  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
E2E-X10MD@12-M1TGJ  
E2E-X7D@12-M1TGJ  
47.1  
3.7  
43.4  
21 dia.  
17  
47.1  
21 dia.  
17  
3.7  
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
4-dia. vinyl-insulated round cable with  
2 conductors(Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
43.4  
33  
33  
7
26  
5.5  
1
12  
10  
4
4
Indicators *  
Indicators *  
Two clamping nuts  
Toothed washer  
M12 × P1  
M12 × P1  
M12 × P1  
M12 × P1  
Two clamping nuts  
Toothed washer  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
E2E-X11D@18-M1TGJ  
E2E-X20MD@L18-M1TGJ  
55.3  
8.5  
77.3  
46.8  
8.5  
6-dia. vinyl-insulated round cable  
with 2 conductors (Conductor cross  
section: AWG20, Insulator diameter:  
1.5 mm), Standard length: 0.3 m  
68.8  
60  
38  
29 dia.  
6-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG20, Insulator diameter: 1.5 mm),  
Standard length: 0.3 m  
29 dia.  
12  
6
13  
47  
4
24  
24  
4
12  
1
Indicators *  
Indicators *  
M12 × P1  
M12 × P1  
M18 × P1  
Two clamping nuts  
Toothed washer  
M18 × P1  
Two clamping nuts  
Toothed washer  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
E2E-X40MD@L30-M1TGJ  
E2E-X20D@30-M1TGJ  
82.3  
8.3  
60.3  
74  
8.3  
6-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG20, Insulator diameter: 1.5 mm),  
Standard length: 0.3 m  
52  
65  
42 dia.  
36  
6-dia. vinyl-insulated round cable  
with 2 conductors (Conductor cross  
section: AWG20, Insulator diameter:  
1.5 mm), Standard length: 0.3 m  
43  
50  
15  
42 dia.  
36  
7
12  
5 10  
4
1
Indicators *  
M12 × P1  
M12 × P1  
Indicators *  
Two clamping nuts  
Toothed washer  
Two clamping nuts  
Toothed washer  
M30 × P1.5  
M30 × P1.5  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
Mounting Hole Dimensions  
Angle R of the Bending Wire  
Wire pullout position  
Sc  
10 mm  
R
(mm)  
Sc  
(mm)  
Dimensions  
M8  
F (mm)  
Dimensions  
Dimensions  
+0.5  
0
8.5 dia.  
12.5 dia.  
18.5 dia.  
30.5 dia.  
M8  
M8  
+0.5  
0
12  
- (0)  
M12  
M12  
M18  
M30  
M12  
M18  
M30  
+0.5  
0
R
M18  
F
+0.5  
0
18  
2.5  
M30  
83  
E2E/E2EQ NEXT Series  
Sensors  
E2EQ NEXT Series (Spatter-resistant Triple distance model)  
DC 2-wire  
Pre-wired Models  
Shielded  
E2EQ-X3D@8  
E2EQ-X7D@12  
47.1  
37.8  
15 dia.  
4.4  
43.4  
33  
21 dia.  
17  
3.7  
4-dia. vinyl-insulated round cable  
with 2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 2 m  
33.4  
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 2 m  
26  
13  
5.5  
4
8
10  
1
1
Indicators *  
Indicators *  
Two clamping nuts  
M8 × P1  
Two clamping nuts  
Toothed washer  
M12 × P1  
Toothed washer  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
E2EQ-X11D@18  
E2EQ-X20D@30  
60.3  
55.3  
52  
43  
8.3  
46.8  
38  
8.5  
29 dia.  
24  
42 dia.  
36  
6-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG20, Insulator diameter: 1.5 mm),  
Standard length: 2 m  
6-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG20, Insulator diameter: 1.5 mm),  
Standard length: 2 m  
7
12  
6
12  
1
1
Indicators  
*
Indicators *  
Two clamping nuts  
Toothed washer  
M18 × P1  
Two clamping nuts  
Toothed washer  
M30 × P1.5  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
Pre-wired Connector Models  
Shielded  
E2EQ-X7D@12-M1TGJ  
E2EQ-X3D@8-M1TGJ  
47.1  
21 dia.  
3.7  
4-dia. vinyl-insulated round cable with  
2 conductors(Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
43.4  
37.8  
4-dia. vinyl-insulated round cable with  
2 conductors(Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
15 dia.  
33.4  
4.4  
17  
33  
26  
5.5  
13  
4
10  
8
1
1
Indicators *  
Two clamping nuts  
Toothed washer  
Indicators *  
Two clamping nuts  
Toothed washer  
M8 × P1  
M12 × P1  
M12 × P1  
M12 × P1  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
E2EQ-X20D@30-M1TGJ  
E2EQ-X11D@18-M1TGJ  
60.3  
55.3  
52  
8.3  
8.5  
6-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG20, Insulator diameter: 1.5 mm),  
Standard length: 0.3 m  
46.8  
38  
6-dia. vinyl-insulated round cable with  
2 conductors(Conductor cross section:  
AWG20, Insulator diameter: 1.5 mm),  
Standard length: 0.3 m  
42 dia.  
43  
29 dia.  
36  
7
12  
6
1
12  
24  
1
Indicators*  
Indicators *  
Two clamping nuts  
Toothed washer  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
M12 × P1  
M18 × P1  
Two clamping nuts  
Toothed washer  
M30 × P1.5  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
Mounting Hole Dimensions  
Angle R of the Bending Wire  
Wire pullout position  
Sc  
10 mm  
R
(mm)  
Sc  
Dimensions  
M8  
F (mm)  
Dimensions  
Dimensions  
(mm)  
+0.5  
0
8.5 dia.  
12.5 dia.  
18.5 dia.  
30.5 dia.  
M8  
M8  
- (0)  
M12  
+0.5  
0
12  
18  
M12  
M12  
M18  
M30  
+0.5  
0
R
M18  
F
M18  
2.5  
+0.5  
0
M30  
M30  
84  
E2E/E2EQ NEXT Series  
Sensors  
E2E NEXT Series (Single distance model)  
DC 2-wire  
Pre-wired Models  
Shielded  
E2E-X1R5D@  
E2E-X2R5D@  
47  
37.6  
3.7  
43.3  
32.9  
4.4  
33.2  
21 dia.  
17  
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 2 m  
15 dia.  
13  
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 2 m  
25.8  
4
10  
3
8
Indicators *  
Two clamping nuts  
Toothed washer  
Indicators *  
Two clamping nuts  
* D1 Models: Operation indicator (Orange),  
Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
M8 × P1  
M12 × P1  
* D1 Models: Operation indicator (Orange),  
Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
Toothed washer  
E2E-X5D@  
54.3  
8.5  
45.8  
29 dia.  
24  
37  
6-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG20, Insulator diameter: 1.5 mm),  
Standard length: 2 m  
4
12  
Indicators *  
M18 × P1  
* D1 Models: Operation indicator (Orange),  
Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
Two clamping nuts  
Toothed washer  
Pre-wired Connector Models  
Shielded  
E2E-X2R5D@-M1TGJ  
E2E-X1R5D@-M1TGJ  
47  
37.6  
4-dia. vinyl-insulated round cable  
with 2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
3.7  
4-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG24, Insulator diameter: 1.05 mm),  
Standard length: 0.3 m  
4.4  
43.3  
21 dia.  
17  
33.2  
15 dia.  
32.9  
25.8  
4
10  
3
8
13  
Indicators *  
Two clamping nuts  
Toothed washer  
Indicators *  
Two clamping nuts  
Toothed washer  
M12 × P1  
M8 × P1  
M12 × P1  
M12 × P1  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
E2E-X5D@-M1TGJ  
54.3  
8.5  
6-dia. vinyl-insulated round cable with  
2 conductors (Conductor cross section:  
AWG20, Insulator diameter: 1.5 mm),  
Standard length: 0.3 m  
45.8  
37  
29 dia.  
4
12  
24  
Indicators *  
Two clamping nuts  
Toothed washer  
M12 × P1  
M18 × P1  
* D1 Models: Operation indicator (Orange), Setting indicator (Green)  
D2 Models: Operation indicator (Orange)  
Mounting Hole Dimensions  
Angle R of the Bending Wire  
Wire pullout position  
Sc  
10 mm  
R
(mm)  
Sc  
(mm)  
Dimensions  
M8  
F (mm)  
Dimensions  
Dimensions  
+0.5  
0
8.5 dia.  
12.5 dia.  
18.5 dia.  
30.5 dia.  
M8  
M8  
+0.5  
0
12  
- (0)  
2.5  
M12  
M12  
M12  
M18  
M30  
+0.5  
0
R
M18  
F
M18  
+0.5  
0
18  
M30  
M30  
85  
E2E/E2EQ NEXT Series  
Accessories (Sold Separately)  
e-jig (Mounting Sleeves)  
Y92E-J12S18  
Y92E-J8S12  
35  
23.3  
28  
3
3
18  
26.8 dia.  
24  
19 dia.  
26.8 dia.  
24  
4
4
21.2 dia.  
19  
17  
M12 × 1  
Sensor lock nut  
Mounting Sleeve  
M18 × 1  
Two Mounting Sleeve  
clamping nuts  
Sensor lock nut  
Mounting Sleeve  
Two Mounting Sleeve  
clamping nuts  
M16×1  
7
0.7  
8.8  
0.7  
M20×1  
8 dia.  
A
A
12 dia.  
Section A-A  
A
A
Section A-A  
Y92E-J18S30  
Material  
Polyetheretherketone (PEEK) /  
40  
Mounting Sleeve  
5
23.2  
Polybutylene terephthalate (PBT)  
Polybutylene terephthalate (PBT)  
Polybutylene terephthalate (PBT)  
5
40 dia.  
36  
40.8 dia.  
36  
Mounting Sleeve  
clamping nut  
Sensor lock nut  
Sensor lock O-ring  
Material combining HNBR and fluororubber  
M30 × 1.5  
Sensor lock nut  
Mounting Sleeve  
Tightening Force  
Two Mounting Sleeve  
clamping nuts  
Torque  
11.9  
M30 × 1.5  
0.7  
Model  
Mounting Sleeve  
Sensor lock nut  
clamping nut  
Y92E-J8S12  
Y92E-J12S18  
Y92E-J18S30  
0.6 N·m  
1.2 N·m  
5 N·m  
0.6 N·m  
1.2 N·m  
3.5 N·m  
18 dia.  
A
A
Section A-A  
86  
Round Oil-resistant Connectors (M12 Smartclick)  
XS5 NEXT Series  
RoundOil-resistiveSmartclickConnectors  
for E2E NEXT Series proximity sensors,  
that are Resistant to Oil,  
and that Reduce Installation Work  
• Uses unique OMRON technology*1 and the same PVC cable with  
increased oil resistance as the E2E NEXT Series proximity sensors.  
Oil-resistance performance values of 2 years*2 when used in  
combination with E2E NEXT Series proximity sensors.  
• Oil-resistant robot cables for use with moving parts such as  
loaders and cableveyors  
For the most recent information on models that have been  
certified for safety standards, refer to your OMRON website.  
• OMRON's unique lock mechanism (Smartclick) that is compatible  
with round M12 connectors.  
• Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.  
• A positive click indicates locking.  
• IP67, IP69K degree of protection.  
• UL approved products.  
*1. Patent pending (as of July, 2018)  
*2. Covered types of oil: Cutting oil specified in JIS K 2241:2000  
The oil-resistance performance value (2 years) indicates the median value (=Typ) at product design, and in evaluation testing results of oil-  
resistance performance. Shipped products will show some variance around this 2 year value in actual usage.  
Features  
Better Cable Oil Resistance, and Improved Overall Oil Resistance with New Rubber  
Material in Mating Sections  
The XS5 NEXT Series uses a special PVC cable that limits deterioration of the cable sheath due to both water-soluble and water-insoluble cutting oil.  
Omron's proprietary molding technique prevents cutting oil intrusion from mating sections. Moreover, using the same new HNBR/fluoride rubber  
as in oil-resistant components of connector mating sections helps improve the overall oil resistance.  
Special PVC Cable +  
Molding Sealing Method  
Special  
Smartclick Structure + O-ring  
Smartclick  
+ O-ring  
Cable /  
Molded  
Seal  
Unique Smartclick Structure  
Cable sheath  
(Special PVC cable)  
Connector tabs  
Blocked.  
Cutting oil  
O-ring Seal  
Blocked. O-ring (New rubber material combining HNBR  
Cutting oil  
Plug  
and fluororubber)  
Socket  
Cover  
O-ring (New rubber material combining HNBR  
and fluororubber)  
Cutting oil  
Patented  
This new material combines the benefits of HNBR and fluororubber  
New  
Rubber  
New Rubber Material Combining
and Fluororubber  
Hydrogenated nitrile butadiene rubber (HNBR), which provides  
superior resistance to oil, was blended with fluororubber in a unique  
OMRON compound to develop a new rubber that provides superior  
resistance to both swelling and deterioration due to cutting oil.  
It is used in seals for joints and moving sections that prevent ingress  
to prevent deterioration and destruction of the seal due to cutting oil,  
resulting in increased oil resistance performance.  
Material  
Deterioration occurs less frequently,  
but cutting oil causes swelling.  
30  
25  
20  
15  
10  
5
HNBR  
Swelling occurs less frequently,  
but cutting oil causes deterioration.  
Fluororubber  
New material  
0
0
5
10  
15  
20  
25  
30  
35  
40  
Deterioration (%)  
87  
XS5 NEXT Series  
P67G quality and Omron's Oil Resistance Component Evaluation System  
for two years of proven oil resistant capability  
*
Oil resistance: 2 years  
OMRON’s Oil-resistant Component  
Evaluation Standards  
Oil type  
A1 (water-soluble cutting oil)  
1,000 hours of machining  
55 °C  
Evaluation  
time  
IP67G  
Oil type N3 (water-insoluble cutting oil)  
Evaluation  
Evaluation  
48 hours  
temperature  
time  
Evaluation  
Room temperature  
Dilution  
temperature  
Undiluted  
concentration  
Dilution  
---  
concentration  
Appearance, performance,  
and no label text loss  
Criteria  
Criteria  
Appearance and performance  
(Illustration)  
(Illustration)  
* Applicable oil types: specified in JIS K 2241:2000  
“2-year oil resistance” refers to median values (=Typical values) of the product designs and the oil-resistance performance evaluation results.  
Products to be shipped will have around 2 years of oil resistance; actual oil resistance will vary depending on the product.  
Varied product lineup to suit the application  
Fixed Parts  
XS5@-D421-@8@-X  
Moving Parts  
XS5@-D421-@8@-XR  
Installation with moving parts  
such as loaders and cableveyors  
Fixed installation  
Model Number Structure  
Model Number Legend  
Use this legend when determining the product specifications from the model number. When ordering, use a model number from the table in  
Ordering Information.  
XS5@-D 4 2 1 - @ 8 @ - X@  
1
2
3
4
5
6
7
8
9
1. Type  
6. Cable Length  
W: Connectors connected to cable, socket and plug on cable ends  
F: Connectors connected to cable, socket on one cable end  
2. Mating Section Form  
C: 1 m  
D: 2 m  
E: 3 m  
G: 5 m  
D: A-coding (for DC sensor)  
3. Connector Poles  
J: 10 m  
4: 4 poles  
7. Connections (Numbers inside circles are terminal numbers)  
8: A Brown, B White, C Blue, DBlack  
8. Connectors on One End/Both Ends  
0: Sockets on One Cable End  
1: Socket and Plug on Cable Ends  
9. Cable Specifications  
4. Contact Plating  
2: Gold plating  
5. Cable Connection Direction  
XS5W 1: Straight (Socket)/Straight (Plug)  
XS5F 1: Straight  
X: Oil-resistant PVC cable  
XR: Oil-resistant PVC robot cable  
is registered trademark of OMRON Corporation.  
88  
XS5 NEXT Series  
Ordering Information  
Connectors  
Cable outer  
diameter (mm)  
Type  
Cable specifications  
Cable length (m)  
Model  
UL  
1
2
XS5W-D421-C81-X  
XS5W-D421-D81-X  
XS5W-D421-E81-X  
XS5W-D421-G81-X  
XS5W-D421-J81-X  
XS5W-D421-C81-XR  
XS5W-D421-D81-XR  
XS5W-D421-E81-XR  
XS5W-D421-G81-XR  
XS5W-D421-J81-XR  
XS5F-D421-C80-X  
XS5F-D421-D80-X  
XS5F-D421-E80-X  
XS5F-D421-G80-X  
XS5F-D421-J80-X  
XS5F-D421-C80-XR  
XS5F-D421-D80-XR  
XS5F-D421-E80-XR  
XS5F-D421-G80-XR  
XS5F-D421-J80-XR  
6 dia.  
Oil-resistant PVC cable  
3
5
10  
1
Socket and Plug  
on Cable Ends  
2
6 dia.  
6 dia.  
Oil-resistant PVC robot cable  
Oil-resistant PVC cable  
3
5
10  
1
UL2238 certified  
(File no. E207683)  
2
3
5
10  
1
Sockets on One  
Cable End  
2
6 dia.  
Oil-resistant PVC robot cable  
3
5
10  
Accessories (Sold Separately)  
Connector Covers  
Water-resistive Covers  
Suitable connector  
Model Mounting portion  
Model  
Material  
Remarks  
This provides IP67 levels of protection.  
When mounting the Water-resistive Cover to a  
Connector, be sure to apply a torque range between  
0.39 and 0.49 N·m to tighten the Water-resistive Cover.  
XS2Z-11  
Brass/nickel plated  
XS5W  
M12 male screw  
This provides IP67 levels of protection.  
This uses the Smart click mechanism. There’s no need  
to keep track of locking torque.  
XS5Z-11  
PBT  
XS5F/XS5W  
M12 female screw  
Water-resistive Covers  
XS2Z-11  
XS5Z-11  
M12 female screw  
XS5Z-11  
M12 male screw  
XS2Z-11  
M12×1  
Dust Covers  
Model  
Suitable connector  
Material  
Remarks  
Model  
XS5W  
Mounting portion  
XS2Z-13  
XS2Z-14  
XS2Z-15  
M12 male screw  
The Dust Cover is for dust prevention and does not  
ensure IP67 degree of protection.  
When mounting the Dust Cover to a connector, be sure  
to press the Dust Cover onto the Connector until the  
Connector is fully inserted into the Dust Cover.  
Contact blocks  
(female contact)  
Rubber/black  
XS5F/XS5W  
M12 female screw  
Dust Covers  
XS2Z-13  
XS2Z-15/XS2Z-14  
M12 male screw  
M12 female screw  
XS2Z-13  
XS2Z-15  
XS2Z-14  
Contact blocks (female contact)  
89  
XS5 NEXT Series  
Ratings and Specifications  
Rated current  
4 A  
Rated voltage  
250 VDC  
Contact resistance (connector)  
Insulation resistance  
Dielectric strength (connector)  
40 mΩ max. (at 20 mV max., 100 mA max.)  
1,000 MΩ min. (at 500 VDC) *1  
1,500 VAC for 1 minute (leakage current: 1 mA max.)  
IP67 (IEC60529)  
IP69K (ISO20653 (formerly DIN Standard 40050 PART9))  
OMRON’s Oil-resistant Component Evaluation Standards *2  
(Cutting oil type JIS K 2241:2000-specification cutting oil, at 35°C or below)  
Degree of protection  
Insertion tolerance  
Lock strength  
50 times  
Tensile: 100 N/15 s, Torsion: 1 N·m/15 s  
Tensile: 100 N/15 s, Torsion: 1 N·m/15 s  
0.1 to 0.25 N·m  
Cable holding strength  
Lock operating force  
Ambient operating temperature range -25 to +70°C *3  
Ambient humidity range  
20 to 85%RH  
*1. State at shipping.  
*2. “OMRON’s Oil-resistant Component Evaluation Standards” are OMRON’s own durability evaluation standards.  
Protection performance with oil-resistive connector (XS5F/W-X) correctly mated.  
This performance does not apply if an oil-resistive connector (XS5F/W-X) is missing, and cord wiring is exposed.  
*3. Use the robot cable within a temperature range of 0 to 70°C to avoid the wire breakage when moving.  
Materials and Finishes  
Model  
XS5F/W-X  
XS5F/W-XR  
Item  
Oil-resistant PVC cable  
Oil-resistant PVC robot cable  
Contacts  
Fixtures  
Fixtures (Lock) *  
Pin block  
O-ring  
Copper alloy/Gold plating  
Zinc alloy/Nickel plating  
Stainless  
PBT resin  
Material combining HNBR and fluororubber  
PBT resin  
Cover  
UL 758 (AWM) 6 mm dia.  
AWG20  
UL 758 (AWM) 6 mm dia.  
AWG21  
Cable  
* Only plug  
Connector Pinout Diagram (from Mating Side)  
Item  
No. of poles  
4 poles  
1
4
Male (plug)  
contacts  
2
3
A-coding  
(For DC  
sensors)  
2
Female(socket)  
contacts  
1
3
4
90  
XS5 NEXT Series  
Connection Combinations  
Plug  
Smartclick Plug Connectors  
M12 Plug Connectors  
XS5H, XS5G,  
XS5W (plug side),  
XS5R (plug side), XS5M *  
XS2H, XS2G,  
XS2W (plug side),  
XS2R (plug side), XS2M *  
Socket  
OMRON model No.  
XS5F, XS5C  
Smartclick Socket  
Connectors  
XS5W (socket side),  
XS5R (socket side),  
XS5P *  
XS2F, XS2C,  
XS2W (socket side),  
XS2R (socket side),  
XS2P *  
M12 Socket Connectors  
* XS2P/XS5P and XS5M, XS2M cannot mate with each other.  
Note: : Connected by twisting.  
: Connected by screwing.  
Dimensions  
(Unit: mm)  
Both end connector type  
XS5W-D421-□81-X  
XS5W-D421-□81-XR  
L (Cable Length)  
44.7  
40.7  
2
1
4
6 dia.  
4
3
2
14.9 dia.  
3
1
M12×1  
M12×1  
Cover (Black)  
Cover (Black)  
Wiring Diagram for 4 Cores  
Pin No.  
Cable color of  
core sheath  
1
2
3
4
1
Brown  
2 White  
3 Blue  
4
Black  
One end connector type  
XS5F-D421-□80-X  
XS5F-D421-□80-XR  
L (Cable Length)  
40.7  
2
1
4
6 dia.  
14.9 dia.  
3
30  
5
Cover (Black)  
M12×1  
50  
Wiring Diagram for 4 Cores  
Pin No.  
Cable color of  
core sheath  
1
2
3
4
1
Brown  
2 White  
3 Blue  
4
Black  
91  
XS5 NEXT Series  
Safety Precautions  
Meaning of Display  
Precautions for Correct Use  
Precautions for  
• Do not use the Connectors in an atmosphere or environment that  
exceeds the specifications.  
Supplementary comments on what to do  
or avoid doing, to use the product safely.  
Safe Use  
• Always turn OFF the power supply before wiring. Failure to turn OFF  
the power supply may lead to electric shock or damage to devices.  
• As usage in environments in which cutting oil is used may impact service  
life and performance, ensure the following requirements are met.  
• Usage with cutting oil requirements as defined in specifications.  
• Usage at a dilution ratio as recommended by cutting oil manufacturers.  
• Usage immersed in oil or water is prohibited.  
Supplementary comments on what to do  
or avoid doing, to prevent failure to  
operate, malfunction, or undesirable  
effects on product performance.  
Precautions for  
Correct Use  
Precautions for Safe Use  
The cutting oil used may have a different impact on product service  
life. Ensure that the product is used only after confirming with the  
customer that there has been no deformation or deterioration of  
seal material from the cutting oil.  
• The mating coupler will impact the oil-resistance performance  
values (years). Confirm mating of the couplers before use.  
Degree of Protection  
Do not use the product if its protective capabilities have been  
compromised, such as through swelling or cracks to housing or seal  
materials.  
If products in this state continue to be used, then cutting oil or other  
contaminants may enter the product, leading to breakages or damage  
from fire.  
Mating Combinations  
Other XS5/  
Connector Connection and Disconnection  
• When connecting or disconnecting Connectors, be sure to hold the  
Connectors by hand.  
XS5@R  
XS5@-X/XR  
XS2 Series  
Oil-resistance  
performance  
values  
Oil-resistance  
performance  
values  
• Do not hold the cable when disconnecting Connectors.  
Check the alignment using the slot in the polarity key.  
• Do not wiring the Connector when your hands are wet. Malfunctions  
or device damage may occur when power is supplied to a device.  
• When mating Connectors, be sure to insert the plug all the way to the  
back of the socket before attempting to lock the Connectors.  
After you lock a Connector, always confirm that it is mated properly.  
• Do not use tools of any sort to mate the Connectors. Always use  
your hands. Pliers or other tools may damage the Connectors.  
• When you replace a Connector, make sure that there is no liquid,  
cutting oil, or other foreign matter on the mating surfaces before  
you mate the Connector.  
XS5@R  
Water-resistance  
4 years  
2 years  
Oil-resistance  
performance  
values  
Oil-resistance  
performance  
values  
XS5@-X/XR  
Water-resistance  
Water-resistance  
2 years  
2 years  
Other  
XS5/XS2  
Series *  
Water-  
resistance  
Water-  
resistance  
* Oil-resistant (polyurethane) cable products (XS5F-P, XS5H-P,  
XS5W-P) as well as oil-resistant (polyurethane) robot cables  
(XS5F-PR, XS5W-PR) are excluded. Please consult with OMRON  
for details of these products.  
Disposal  
• Environments with corrosive gases and high temperature and  
humidity can cause bad connections and damage through  
corrosion, leading to degraded performance, therefore do not use  
these products in such environments.  
Dispose of this product as industrial waste.  
• Do not pull on the Connectors or cables with excessive force.  
• Do not step on or place any objects on the Connectors. Doing so  
may damage the Connectors.  
• Lay the cable where it will not be stepped on to prevent the wires  
in the cable from being disconnected and to protect the Connectors  
from being damaged. If the cable must be placed where it will be  
stepped on, install a protective cover.  
• At installation, if not installing sensors or switches, and not mating  
plug connectors, then use water-resistant covers (XS5Z-11, XS2Z-  
11) or dust-resistant covers (XS2Z-13/14/15) in order to ensure  
correct connector mating.  
Wiring  
• Do not wire cables in environments in which the cable terminal  
sections will be subject to fluids such as water or cutting oil.  
• When wiring cables, ensure this is carried out in accordance with  
the wiring diagram.  
• Lay the cables so that external force is not applied to the  
Connectors. Otherwise, the degree of protection (IP67G) may not  
be achieved.  
Degree of Protection (IP67)  
• The degree of protection of Connectors (IP67) is not for a fully  
watertight structure. Do not use the Connectors underwater.  
• Do not step on or place any objects on the Connectors. Doing so  
may damage the Connectors.  
92  
XS5 NEXT Series  
Setup  
• Do not install the Connectors with a load placed directly on the joint  
or at the point where the wires connect to the Connector.  
The Connector may be damaged or the wires in the cable may be  
disconnected.  
• If bending cables, ensure that these use a minimum bend radius of  
40 mm.  
Please do not bend  
from the root portion on the cable  
Providing a straight section  
from the root portion on the cable  
The radius of  
40 mm or more  
Connecting  
1. Connecting the XS5 Plug and Socket  
2. Connecting the XS5 and XS2  
Align the projection on the plug cover with the polarity key on the  
socket, then insert the plug all the way in.  
Align the projection on the plug cover with the polarity key on the  
socket, then insert the plug all the way in.  
In the same way as when connecting two XS2 Connectors, screw  
the knurled grip in the clockwise direction.  
• When mating the products to XS2 or other M12 Connectors,  
Polarity key  
Protrusion on  
cover aligns with  
polarity key.  
tighten the lock to a torque of 0.39 to 0.49 N  
-m.  
Hold the knurled socket grip, then insert the projection on the plug  
into the groove of the socket.  
Socket  
Plug  
Fixtures (grip)  
Turn the knurled grips of the socket clockwise approximately 1/8  
turn in respect to the plug. A click will indicate that the Connectors  
are locked. The locking condition can also be confirmed by the  
alignment marks on the plug and socket.  
Alignment marks  
93  
Round Water-resistant Connectors (M12 Smartclick)  
XS5  
Round Water-resistive Smartclick  
Connectors for E2E NEXT Series  
proximity sensors that  
Reduce Installation Work  
• A newly developed lock mechanism that is compatible  
with round M12 connectors.  
• Simply insert the Connectors, then turn them  
approximately 1/8 of a turn to lock.  
• A positive click indicates locking.  
• IP67 degree of protection.  
• UL approved products.  
For the most recent information on models that have been certified for  
safety standards, refer to your OMRON website.  
Be sure to read Safety Precautions on  
page 100.  
Model Number Structure  
Model Number Legend  
Use this legend when determining the product specifications from the model number. When ordering, use a model number from the table in  
Ordering Information.  
XS5@-D 4 2 @ - @ 8 @ - F  
1
2
3
4
5
6
7
8
9
1. Type  
6. Cable Length  
C: 1 m  
W: Connectors connected to cable, socket and plug on cable ends  
F: Connectors connected to cable, socket on one cable end  
D: 2 m  
E: 3 m  
G: 5 m  
J: 10 m  
2. Mating Section Form  
D: A-coding (for DC sensor)  
3. Connector Poles  
7. Connections (Numbers inside circles are terminal numbers)  
8: ABrown, BWhite, CBlue, DBlack  
4: 4 poles  
4. Contact Plating  
2: Gold plating  
8. Connectors on One End/Both Ends  
0: Sockets on One Cable End  
5. Cable Connection Direction  
XS5W  
1: Socket and Plug on Cable Ends  
1: Straight (Socket)/Straight (Plug)  
2: Right-angle (Socket)/Right-angle (Plug)  
3: Straight (Socket)/Right-angle (Plug)  
4: Right-angle (Socket)/Straight (Plug)  
9. Cable Specifications  
F: Robot cable  
XS5F  
1: Straight  
2: Right-angle  
is registered trademark of OMRON Corporation.  
94  
XS5  
Ordering Information  
Connectors  
Cable outer  
diameter  
(mm)  
Cable  
length (m)  
Type  
Cable Connection Direction  
Model  
UL  
1
2
XS5W-D421-C81-F  
XS5W-D421-D81-F  
XS5W-D421-E81-F  
XS5W-D421-G81-F  
XS5W-D421-J81-F  
XS5W-D422-D81-F  
XS5W-D422-G81-F  
XS5W-D423-D81-F  
XS5W-D423-G81-F  
XS5W-D424-D81-F  
XS5W-D424-G81-F  
XS5F-D421-C80-F  
XS5F-D421-D80-F  
XS5F-D421-E80-F  
XS5F-D421-G80-F  
XS5F-D421-J80-F  
XS5F-D422-C80-F  
XS5F-D422-D80-F  
XS5F-D422-E80-F  
XS5F-D422-G80-F  
XS5F-D422-J80-F  
Straight (Socket)/Straight (Plug)  
3
5
10  
2
Socket and Plug  
on Cable Ends  
XS5W  
6 dia.  
Right-angle (Socket)/Right-angle (Plug)  
Straight (Socket)/Right-angle (Plug)  
Right-angle (Socket)/Straight (Plug)  
5
2
5
2
UL2238 certified  
(File no.  
5
E207683)  
1
2
Straight type  
3
5
Sockets on One  
Cable End  
XS5F  
10  
1
6 dia.  
2
Right-angle type  
3
5
10  
95  
XS5  
Accessories (Sold Separately)  
Connector Covers  
Water-resistive Covers  
Suitable connector  
Model Mounting portion  
Model  
Material  
Remarks  
This provides IP67 levels of protection.  
Brass/  
Nickel plated  
When mounting the Water-resistive Cover to a Connector, be sure to  
apply a torque range between 0.39 and 0.49 N·m to tighten the Water-  
resistive Cover.  
XS2Z-11  
XS5W  
M12 male screw  
This provides IP67 levels of protection.  
M12 female screw This uses the Smart click mechanism. There’s no need to keep track  
of locking torque.  
XS5Z-11  
PBT  
XS5F/XS5W  
Water-resistive Covers  
XS2Z-11  
XS5Z-11  
M12 female screw  
XS5Z-11  
M12 male screw  
XS2Z-11  
M12×1  
Dust Covers  
Suitable connector  
Model  
Material  
Remarks  
Model  
XS5W  
Mounting portion  
XS2Z-13  
XS2Z-14  
XS2Z-15  
M12 male screw  
The Dust Cover is for dust prevention and does not ensure IP67  
degree of protection.  
When mounting the Dust Cover to a connector, be sure to press the  
Dust Cover onto the Connector until the Connector is fully inserted  
into the Dust Cover.  
Contact blocks  
(female contact)  
Rubber/Black  
XS5F/XS5W  
M12 female screw  
Dust Covers  
XS2Z-13  
XS2Z-15/XS2Z-14  
M12 male screw  
M12 female screw  
XS2Z-13  
XS2Z-15  
XS2Z-14  
Contact blocks (female contact)  
96  
XS5  
Ratings and Specifications  
Rated current  
4 A  
Rated voltage  
250 VDC  
Contact resistance (connector)  
Insulation resistance  
Dielectric strength (connector)  
Degree of protection  
Insertion tolerance  
40 mΩ max. (at 20 mV max., 100 mA max.)  
1,000 MΩ min. (at 500 VDC) *1  
1,500 VAC for 1 minute (leakage current: 1 mA max.)  
IP67 (IEC 60529)  
50 times  
Lock strength  
Tensile: 100 N/15 s, Torsion: 1 N·m/15 s  
Tensile: 100 N/15 s, Torsion: 1 N·m/15  
0.1 to 0.25 N·m  
Cable holding strength  
Lock operating force  
Ambient operating temperature range -25 to 70°C *2  
Ambient humidity range  
20 to 85%RH  
*1. State at shipping.  
*2. Use the robot cable within a temperature range of 0 to 70°C to avoid the wire breakage when moving.  
Materials and Finishes  
Connector Pinout Diagram  
(from Mating Side)  
Model  
XS5W/XS5F  
Item  
Item  
No. of poles  
4 poles  
Contacts  
Fixtures  
Pin block  
O-ring  
Copper alloy/Gold plating  
Zinc alloy/Nickel plationg  
PBT resin  
1
4
Male (plug)  
contacts  
2
3
A-coding  
(For DC  
sensors)  
Rubber  
Cover  
PBT resin  
2
Female(socket)  
contacts  
UL13 (CL3), UL758 (AWM), 6 mm dia.,  
AWG20  
Cable  
1
3
4
Connection  
Plug  
Smartclick Plug Connectors  
M12 Plug Connectors  
XS5H, XS5G,  
XS5W (plug side),  
XS5R (plug side), XS5M *  
XS2H, XS2G,  
XS2W (plug side),  
XS2R (plug side), XS2M *  
Socket  
OMRON model No.  
XS5F, XS5C  
Smartclick Socket  
Connectors  
XS5W (socket side),  
XS5R (socket side),  
XS5P *  
XS2F, XS2C,  
XS2W (socket side),  
XS2R (socket side),  
XS2P *  
M12 Socket Connectors  
* XS2P/XS5P and XS5M, XS2M cannot mate with each other.  
Note: : Connected by twisting.  
: Connected by screwing.  
97  
XS5  
Dimensions  
(Unit: mm)  
Socket and Plug on Cable Ends XS5W  
Straight (Socket)/straight (Plug)  
XS5W-D421-@81-F  
M12×1  
1
2
3
4
3
14.9 dia.  
14.9 dia.  
2
1
4
40.7  
44.7  
M12×1.0  
L (Cable Length)  
Right-angle (Socket)/right-angle (Plug)  
XS5W-D422-@81-F  
L (Cable Length  
)
25.3  
25.3  
28.3  
32.3  
M12×1  
14.9 dia.  
14.9 dia.  
2
3
4
3
2
1
Wiring Diagram for 4 Cores  
1
4
Pin No.  
Cable color of  
core sheath  
M12×1.0  
1
2
3
4
1
Brown  
2 White  
3 Blue  
Straight (Socket)/right-angle (Plug)  
XS5W-D423-@81-F  
4
Black  
L (Cable Length  
)
40.7  
25.3  
1
2
3
14.9 dia.  
4
32.3  
M12×1.0  
M12×1  
14.9 dia.  
2
3
1
4
Right-angle (Socket)/straight (Plug)  
XS5W-D424-@81-F  
L (Cable Length  
)
44.7  
25.3  
4
3
14.9 dia.  
2
1
28.3  
M12×1  
14.9 dia.  
3
4
2
1
M12×1.0  
98  
XS5  
Sockets on One Cable End XS5F  
Straight type  
XS5F-D421-@80-F  
L (Cable Length)  
40.7  
1
2
3
14.9 dia.  
4
30  
5
Wiring Diagram for 4 Cores  
M12×1.0  
50  
Cable color of  
core sheath  
Pin No.  
Right-angle type  
XS5F-D422-@80-F  
1
Brown  
White  
Blue  
1
2
3
4
2
3
4
Black  
L (Cable Length  
)
25.3  
28.3  
30  
5
50  
14.9 dia.  
3
4
2
1
M12×1.0  
99  
XS5  
Safety Precautions  
Wiring  
Meaning of Display  
• Do not wire cables in environments in which the cable terminal  
sections will be subject to fluids such as water or cutting oil.  
• When wiring cables, ensure this is carried out in accordance with  
the wiring diagram.  
• Lay the cables so that external force is not applied to the  
Connectors. Otherwise, the degree of protection (IP67G) may not  
be achieved.  
Precautions for  
Supplementary comments on what to do  
or avoid doing, to use the product safely.  
Safe Use  
Supplementary comments on what to do  
or avoid doing, to prevent failure to  
operate, malfunction, or undesirable  
effects on product performance.  
Precautions for  
Correct Use  
Degree of Protection (IP67)  
• The degree of protection of Connectors (IP67) is not for a fully  
watertight structure. Do not use the Connectors underwater.  
• Do not step on or place any objects on the Connectors. Doing so  
may damage the Connectors.  
Precautions for Safe Use  
Degree of Protection  
Do not use the product if its protective capabilities have been  
compromised, such as through swelling or cracks to housing or seal  
materials.  
Setup  
Breakages or damage from fire may occur when products in this state  
continue to be used.  
• Do not install the Connectors with a load placed directly on the joint  
or at the point where the wires connect to the Connector.  
The Connector may be damaged or the wires in the cable may be  
disconnected.  
• If bending cables, ensure that these use a minimum bend radius of  
40 mm.  
Connector Connection and Disconnection  
• When connecting or disconnecting Connectors, be sure to hold the  
Connectors by hand.  
• Do not hold the cable when disconnecting Connectors.  
Check the alignment using the slot in the polarity key.  
• Do not wiring the Connector when your hands are wet. Malfunctions  
or device damage may occur when power is supplied to a device.  
• When mating Connectors, be sure to insert the plug all the way to the  
back of the socket before attempting to lock the Connectors.  
After you lock a Connector, always confirm that it is mated properly.  
• Do not use tools of any sort to mate the Connectors. Always use  
your hands. Pliers or other tools may damage the Connectors.  
• When you replace a Connector, make sure that there is no liquid,  
cutting oil, or other foreign matter on the mating surfaces before  
you mate the Connector.  
Please do not bend  
from the root portion on the cable  
Disposal  
Dispose of this product as industrial waste.  
Providing a straight section  
from the root portion on the cable  
Precautions for Correct Use  
• Do not use the Connectors in an atmosphere or environment that  
exceeds the specifications.  
• Always turn OFF the power supply before wiring. Failure to turn OFF  
the power supply may lead to electric shock or damage to devices.  
• Environments with corrosive gases and high temperature and  
humidity can cause bad connections and damage through  
corrosion, leading to degraded performance, therefore do not use  
these products in such environments.  
The radius of  
40 mm or more  
• Do not pull on the Connectors or cables with excessive force.  
• Do not step on or place any objects on the Connectors. Doing so  
may damage the Connectors.  
• Lay the cable where it will not be stepped on to prevent the wires  
in the cable from being disconnected and to protect the Connectors  
from being damaged. If the cable must be placed where it will be  
stepped on, install a protective cover.  
• At installation, if not installing sensors or switches, and not mating  
plug connectors, then use water-resistant covers (XS5Z-11, XS2Z-  
11) or dust-resistant covers (XS2Z-13/14/15) in order to ensure  
correct connector mating.  
100  
XS5  
Connecting  
1. Connecting the XS5 Plug and Socket  
Align the projection on the plug cover with the polarity key on the  
socket, then insert the plug all the way in.  
Polarity key  
Protrusion on  
cover aligns with  
polarity key.  
Hold the knurled socket grip, then insert the projection on the plug  
into the groove of the socket.  
Socket  
Plug  
Fixtures (grip)  
Turn the knurled grips of the socket clockwise approximately 1/8  
turn in respect to the plug. A click will indicate that the Connectors  
are locked. The locking condition can also be confirmed by the  
alignment marks on the plug and socket.  
Alignment marks  
2. Connecting the XS5 and XS2  
Align the projection on the plug cover with the polarity key on the  
socket, then insert the plug all the way in.  
In the same way as when connecting two XS2 Connectors, screw  
the knurled grip in the clockwise direction.  
Use your fingers to tighten the Connectors sufficiently.  
101  
Round Water-resistant Connectors (M8)  
XS3W-M8/XS3F-M8  
Small Round Water-resistive  
Connectors  
• Water-resistive, compact connector meets IP67  
requirements.  
• M8 Screw-on Connectors  
• Connectors on both cable ends require no harness  
work.  
• Compliant with IEC61076-2-104  
• UL approved products.  
Refer to Safety Precautions on page 106.  
Model Number Structure  
Model Number Legend  
Use this model number legend to identify products from their model number. Use this model number legend to identify products from their model  
number. When ordering, use a model number from the table in Ordering Information.  
XS3@ - M 8 P V C @ @ @  
3
1
2
5
6
4
1. Type  
5. Cable Connection Direction  
XS3W-M8  
W: Socket and Plug on Cable Ends  
F: Sockets on One Cable End  
SS: Straight (Plug)/Straight (Socket)  
SA: Straight (Plug)/Right-angle (Socket)  
2. Fastening Method  
XS3F-M8  
S: Straight  
A: Right-angle  
M8: M8 type  
3. Cable Material  
PVC: PVC Cable  
6. Cable Length  
2M: 2 m  
4. Connector Poles  
3: 3 poles  
5M: 5 m  
10M: 10 m  
4: 4 poles  
102  
XS3W-M8/XS3F-M8  
Ordering Information  
Cable  
specifications  
Cable outer  
diameter (mm)  
No. of cable  
cores (Poles)  
Cable connection  
direction  
Cable length  
(m)  
Type  
Model  
UL  
2
5
XS3W-M8PVC3SS2M  
XS3W-M8PVC3SS5M  
XS3W-M8PVC3SS10M  
XS3W-M8PVC3SA2M  
XS3W-M8PVC3SA5M  
XS3W-M8PVC3SA10M  
XS3W-M8PVC4SS2M  
XS3W-M8PVC4SS5M  
XS3W-M8PVC4SS10M  
XS3W-M8PVC4SA2M  
XS3W-M8PVC4SA5M  
XS3W-M8PVC4SA10M  
XS3F-M8PVC3S2M  
XS3F-M8PVC3S5M  
XS3F-M8PVC3S10M  
XS3F-M8PVC3A2M  
XS3F-M8PVC3A5M  
XS3F-M8PVC3A10M  
XS3F-M8PVC4S2M  
XS3F-M8PVC4S5M  
XS3F-M8PVC4S10M  
XS3F-M8PVC4A2M  
XS3F-M8PVC4A5M  
XS3F-M8PVC4A10M  
Straight (Plug)/  
Straight (Socket)  
10  
2
3
4
3
4
Straight (Plug)/  
Right-angle (Socket)  
5
10  
2
Socket and Plug  
on Cable Ends  
Straight (Plug)/  
Straight (Socket)  
5
10  
2
Straight (Plug)/  
Right-angle (Socket)  
5
UL2238  
certified  
(File no.  
E207683)  
10  
2
PVC cable  
5.0 dia.  
Straight type  
5
10  
2
Right-angle type  
Straight type  
5
10  
2
Sockets on One  
Cable End  
5
10  
2
Right-angle type  
5
10  
Ratings and Specifications  
Item  
Model  
XS3W-M8/XS3F-M8  
Rated current  
Rated voltage  
1 A  
125 VDC  
Contact resistance (connector) 40 mΩ max. (20 mV max., 100 mA max.)  
Insulation resistance 1,000 MΩ min. (at 500 VDC)  
Dielectric strength (connector) 1,000 VAC for 1 min (leakage current: 1 mA max.)  
Degree of protection  
Insertion tolerance  
Cable tensile strength  
IP67 (IEC60529)  
200 times  
49 N/15 s  
Ambient operating temperature  
range  
-10 to 80°C  
Ambient humidity range  
20 to 85%RH  
Materials and Finish  
Pin Arrangement (Engaged Side)  
Item  
Model  
XS3W-M8/XS5F-M8  
Copper alloy/Gold plating  
Copper alloy/Nickel plating  
PBT resin  
Item  
Poles  
3 poles  
4 poles  
Contacts  
Fixture  
Contact block  
O-ring  
4
2
1
4
Male (plug)  
1
3
3
contacts  
DC  
Rubber  
4
Cover  
PBT resin  
4
3
2
Female(socket)  
contacts  
3
1
1
Cable  
5 mm dia, AWG23, PVC  
103  
XS3W-M8/XS3F-M8  
Dimensions  
(Unit: mm)  
Connectors on both cable ends XS3W-M8  
Straight (Plug)/Straight (Socket)  
XS3W-M8PCV3SS@M (3 poles)  
L
32  
31.4  
4
4
10 dia.  
9 dia.  
1
3
3
1
M8×1  
M8×1  
XS3W-M8PCV4SS@M (4 poles)  
L
32  
31.4  
4
2
4
3
2
10 dia.  
9 dia.  
3
1
1
M8×1  
M8×1  
Straight (Plug)/Right-angle (Socket)  
XS3W-M8PCV3SA@M (3 poles)  
L
32  
23.1  
4
10 dia.  
3
1
20.5  
M8×1  
9 dia.  
3
4
1
M8×1  
XS3W-M8PCV4SA@M (4 poles)  
L
32  
23.1  
4
3
2
10 dia.  
1
20.5  
M8×1  
9 dia.  
3
4
1
2
M8×1  
Wiring Diagram  
3 Cores  
4 Cores  
Pin No.  
Cable lead colors  
Pin No.  
Cable lead colors  
1
2
1
2
1
1
Brown  
White  
Blue  
Brown  
3
4
3
4
3
4
3
Blue  
Black  
4
Black  
104  
XS3W-M8/XS3F-M8  
Connectors on both cable ends XS3F-M8  
Straight Connectors  
XS3F-M8PCV3S@M (3 poles)  
L
31.4  
4
9 dia.  
3
1
5
30  
M8×1  
50  
XS3F-M8PCV4S@M (4 poles)  
L
31.4  
4
2
1
9 dia.  
3
5
30  
M8×1  
50  
Right-Angle Connectors  
XS3F-M8PCV3A@M (3 poles)  
L
23.1  
5
20.5  
30  
50  
9 dia.  
1
4
3
M8×1  
XS3F-M8PCV4A@M (4 poles)  
L
23.1  
5
20.5  
30  
50  
9 dia.  
2
4
1
3
M8×1  
Wiring Diagram  
3 Cores  
4 Cores  
Wiring Diagram  
Wiring Diagram  
Pin No.  
Cable lead colors  
Pin No.  
Cable lead colors  
Brown  
1
2
3
4
Brown  
White  
Blue  
1
3
4
Blue  
Black  
Black  
105  
XS3W-M8/XS3F-M8  
Safety Precautions  
Degree of Protection  
Meaning of Display  
• Do not impose external force continuously on the joints of pin  
blocks and covers, otherwise the Connectors may not keep its  
proper degree of protection (i.e., IP67).  
• The degree of protection of connectors (IP67) is not for a fully  
watertight structure. Do not use them underwater.  
• The Connectors are not oil-resistant. Do not use them where they  
would be subject to oil.  
Supplementary comments on what to  
do or avoid doing, to use the product  
safely.  
Precautions for  
Safe Use  
Supplementary comments on what to  
do or avoid doing, to prevent failure to  
operate, malfunction, or undesirable  
effects on product performance.  
Precautions for  
Correct Use  
• If Connectors are used in places with vibration or shock, secure the  
mating section of each Connector, otherwise the Connectors may  
be disconnected or fail to maintain their proper degree of  
protection.  
• Connectors are of resin mold construction. Do not impose  
excessive force on them.  
Precautions for Safe Use  
Disposal  
Dispose of this product as industrial waste.  
Precautions for Correct Use  
Storage  
Do not store Connectors for long periods of time in the following  
locations  
• Locations subject to dust or high humidity  
• Locations subject to ammonia gas or sulfide gas  
Do not use the product in atmospheres or environments that exceed  
product ratings.  
Connections  
• The XS3 and XS2 Sensor I/O Connectors cannot be connected to  
each other.  
Setup  
• Do not make any cable bends near the base of the Unit.  
• Any bends made must have a minimum radius of 36 mm.  
• You cannot mate Connectors that have a different number of  
poles.  
• When using Sensors with Connectors or Limit Switches, use the  
Sensor I/O Connectors specified in the catalog.  
Connector Connection and Disconnection  
• Before connecting or disconnecting Connectors, make sure that no  
power is being supplied to the Connectors.  
• When connecting or disconnecting Connectors, be sure to hold the  
Connectors by hand. Do not disconnect the Connectors by pulling  
the cable.  
• Do not touch the mating surface of the connectors with wet hands.  
If there is any water on the Connector or near the Connector, be  
sure to wipe off the water before connecting or disconnecting the  
Connector, otherwise the Connector may short-circuit internally or  
not ensure good insulation.  
• Make sure that mating section of any Connector is free of metal  
dust or power.  
• Do not use tools of any sort to mate the Connectors. Always use  
your hands. Pliers or other tools may damage the Connectors. Be  
sure to tighten each thread bracket by hand within a torque of 0.2  
N·m. If the thread bracket is not tightened securely, the Connector  
may not maintain its proper degree of protection or the thread  
bracket may fall off due to vibration.  
• When you tighten or loosen a thread bracket, hold onto only the  
thread bracket.  
If you hold onto the cover or cable, excessive rotational force will  
be applied to the Connector and may damage it.  
106  
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have  
any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing  
by Omron). Omron disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE  
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL  
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products  
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,  
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the  
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price  
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other  
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,  
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by  
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or  
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system  
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in  
writing, are not to be construed as an amendment or addition to the above warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is  
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,  
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with  
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it  
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice  
to change part numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be  
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to  
confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
is a registered trademark of OMRON Corporation.  
Company names and product names in this document are the trademarks or registered trademarks of their respective companies.  
The product photographs and figures that are used in this catalog may vary somewhat from the actual products.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Kyoto, JAPAN  
Industrial Automation Company  
Authorized Distributor:  
Contact: www.ia.omron.com  
Regional Headquarters  
OMRON EUROPE B.V.  
Wegalaan 67-69, 2132 JD Hoofddorp  
The Netherlands  
OMRON ELECTRONICS LLC  
2895 Greenspoint Parkway, Suite 200  
Hoffman Estates, IL 60169 U.S.A.  
Tel: (31)2356-81-300/Fax: (31)2356-81-388  
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787  
© OMRON Corporation 2018-2019 All Rights Reserved.  
In the interest of product improvement,  
specifications are subject to change without notice.  
OMRON (CHINA) CO., LTD.  
Room 2211, Bank of China Tower,  
200 Yin Cheng Zhong Road,  
PuDong New Area, Shanghai, 200120, China  
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  
OMRON ASIA PACIFIC PTE. LTD.  
No. 438A Alexandra Road # 05-05/08 (Lobby 2),  
Alexandra Technopark,  
Singapore 119967  
Tel: (65) 6835-3011/Fax: (65) 6835-2711  
CSM_1_5_0819  
Cat. No. D121-E1-03  
0819(1218)  

相关型号:

E2E-X8B218-R5M

Inductive Sensor,
OMRON

E2E-X8B2L185M

Inductive Sensor,
OMRON

E2E-X8B3D18-M1TJR0.3M

Inductive Sensor,
OMRON

E2E-X8B3D18-R2M

Inductive Sensor,
OMRON

E2E-X8C118-M1

Inductive Sensor,
OMRON

E2E-X8C118-M1TJ0.3M

Inductive Sensor,
OMRON

E2E-X8C118-M1TJR0.3M

Inductive Sensor,
OMRON

E2E-X8C118-R2M

Inductive Sensor,
OMRON

E2E-X8C1L18-M1

Inductive Sensor,
OMRON

E2E-X8C1L18-M1TJ0.3M

Inductive Sensor,
OMRON

E2E-X8C1L182M

Inductive Sensor,
OMRON

E2E-X8C218-M1

Inductive Sensor,
OMRON