Cylindrical Proximity Sensor E2EL  
A new series of easy–to–use models for  
standard– and double–distance  
Stainless steel and brass housing  
Two housing length for each type  
Pre–wired and Plug–in connector types  
Short–circuit protection and reverse pola-  
rity protection  
Ordering Information  
Cable types  
Brass housing  
Output  
Diameter  
Length  
Mounting  
Sensing  
Distance  
NPN / NO  
E2EL–C1R5E1 2M  
E2EL–C2ME1 2M  
NPN / NC  
E2EL–C1R5E2 2M  
E2EL–C2ME2 2M  
PNP / NO  
PNP / NC  
E2EL–C1R5F2 2M  
E2EL–C2MF2 2M  
6,5  
30 mm  
32 mm  
45 mm  
47 mm  
30 mm  
32 mm  
45 mm  
47 mm  
41 mm  
Shielded  
1,5 mm  
E2EL–C1R5F1 2M  
E2EL–C2MF1 2M  
Non–shielded 2,0 mm  
Shielded 1,5 mm  
Non–shielded 2,0 mm  
Shielded 1,5 mm  
Non–shielded 2,0 mm  
Shielded 1,5 mm  
Non–shielded 2,0 mm  
E2EL–C1R5E1–L 2M E2EL–C1R5E2–L 2M E2EL–C1R5F1–L 2M E2EL–C1R5F2–L 2M  
E2EL–C2ME1–L 2M  
E2EL–X1R5E1 2M  
E2EL–X2ME1 2M  
E2EL–C2ME2–L 2M  
E2EL–X1R5E2 2M  
E2EL–X2ME2 2M  
E2EL–C2MF1–L 2M  
E2EL–X1R5F1 2M  
E2EL–X2MF1 2M  
E2EL–C2MF2–L 2M  
E2EL–X1R5F2 2M  
E2EL–X2MF2 2M  
M8  
E2EL–X1R5E1–L 2M E2EL–X1R5E2–L 2M E2EL–X1R5F1–L 2M E2EL–X1R5F2–L 2M  
E2EL–X2ME1–L 2M  
E2EL–X2E1 2M  
E2EL–X2ME2–L 2M  
E2EL–X2E2 2M  
E2EL–X2MF1–L 2M  
E2EL–X2F1 2M  
E2EL–X2MF2–L 2M  
E2EL–X2F2 2M  
M12  
Shielded  
Shielded  
2,0 mm  
4,0 mm  
E2EL–X4E1–D 2M  
E2EL–X4ME1 2M  
E2EL–X2E1–L 2M  
E2EL–X4E1–DL 2M  
E2EL–X4ME1–L 2M  
E2EL–X5E1 2M  
E2EL–X4E2–D 2M  
E2EL–X4ME2 2M  
E2EL–X2E2–L 2M  
E2EL–X4E2–DL 2M  
E2EL–X4ME2–L 2M  
E2EL–X5E2 2M  
E2EL–X4F1–D 2M  
E2EL–X4MF1 2M  
E2EL–X2F1–L 2M  
E2EL–X4F1–DL 2M  
E2EL–X4MF1–L 2M  
E2EL–X5F1 2M  
E2EL–X4F2–D 2M  
E2EL–X4MF2 2M  
E2EL–X2F2–L 2M  
E2EL–X4F2–DL 2M  
E2EL–X4MF2–L 2M  
E2EL–X5F2 2M  
Non–shielded 4,0 mm  
53 mm  
40 mm  
73 mm  
Shielded  
Shielded  
2,0 mm  
4,0 mm  
Non–shielded 4,0 mm  
M18  
M30  
Shielded  
Shielded  
5,0 mm  
8,0 mm  
E2EL–X8E1–D 2M  
E2EL–X8ME1 2M  
E2EL–X5E1–L 2M  
E2EL–X8E1–DL 2M  
E2EL–X8ME1–L 2M  
E2EL–X10E1 2M  
E2EL–X15ME1 2M  
E2EL–X10E1–L 2M  
E2EL–X8E2–D 2M  
E2EL–X8ME2 2M  
E2EL–X5E2–L 2M  
E2EL–X8E2–DL 2M  
E2EL–X8ME2–L 2M  
E2EL–X10E2 2M  
E2EL–X15ME2 2M  
E2EL–X10E2–L 2M  
E2EL–X8F1–D 2M  
E2EL–X8MF1 2M  
E2EL–X5F1–L 2M  
E2EL–X8F1–DL 2M  
E2EL–X8MF1–L 2M  
E2EL–X10F1 2M  
E2EL–X15MF1 2M  
E2EL–X10F1–L 2M  
E2EL–X8F2–D 2M  
E2EL–X8MF2 2M  
E2EL–X5F2–L 2M  
E2EL–X8F2–DL 2M  
E2EL–X8MF2–L 2M  
E2EL–X10F2 2M  
E2EL–X15MF2 2M  
E2EL–X10F2–L 2M  
Non–shielded 8,0 mm  
Shielded  
Shielded  
5,0 mm  
8,0 mm  
Non–shielded 8,0 mm  
Shielded 10,0 mm  
Non–shielded 15,0 mm  
Shielded 10,0 mm  
Non–shielded 15,0 mm  
40 mm  
80 mm  
E2EL–X15ME1–L 2M E2EL–X15ME2–L 2M E2EL–X15MF1–L 2M E2EL–X15MF2–L 2M  
1
E2EL  
E2EL  
Stainless steel housing  
Output  
Diameter  
6,5  
M8  
Length  
Mounting  
Sensing  
Distance  
NPN / NO  
NPN / NC  
E2EL–C2E2–DS 2M  
PNP / NO  
PNP / NC  
E2EL–C2F2–DS 2M  
30 mm  
45 mm  
30 mm  
45 mm  
41 mm  
53 mm  
40 mm  
73 mm  
Shielded  
Shielded  
Shielded  
Shielded  
Shielded  
Shielded  
Shielded  
Shielded  
2,0 mm  
2,0 mm  
2,0 mm  
2,0 mm  
4,0 mm  
4,0 mm  
8,0 mm  
8,0 mm  
E2EL–C2E1–DS 2M  
E2EL–C2F1–DS 2M  
E2EL–C2E1–DSL 2M E2EL–C2E2–DSL 2M E2EL–C2F1–DSL 2M E2EL–C2F2–DSL 2M  
E2EL–X2E1–DS 2M E2EL–X2E2–DS 2M E2EL–X2F1–DS 2M E2EL–X2F2–DS 2M  
E2EL–X2E1–DSL 2M E2EL–X2E2–DSL 2M E2EL–X2F1–DSL 2M E2EL–X2F2–DSL 2M  
E2EL–X4E1–DS 2M E2EL–X4E2–DS 2M E2EL–X4F1–DS 2M E2EL–X4F2–DS 2M  
E2EL–X4E1–DSL 2M E2EL–X4E2–DSL 2M E2EL–X4F1–DSL 2M E2EL–X4F2–DSL 2M  
E2EL–X8E1–DS 2M E2EL–X8E2–DS 2M E2EL–X8F1–DS 2M E2EL–X8F2–DS 2M  
M12  
M18  
E2EL–X8E1–DSL 2M E2EL–X8E2–DSL 2M E2EL–X8F1–DSL 2M E2EL–X8F2–DSL 2M  
Plug types  
Brass housing  
Output  
Diameter /  
Length  
Mounting  
Sensing  
Distance  
Connection  
NPN / NO  
E2EL–C1R5E1–M3  
E2EL–C2ME1–M3  
NPN / NC  
E2EL–C1R5E2–M3  
E2EL–C2ME2–M3  
PNP / NO  
E2EL–C1R5F1–M3  
E2EL–C2MF1–M3  
PNP / NC  
E2EL–C1R5F2–M3  
E2EL–C2MF2–M3  
6,5 /  
45 mm  
47 mm  
54 mm  
56 mm  
45 mm  
47 mm  
54 mm  
56 mm  
44 mm  
Shielded  
1,5 mm  
Plug M8  
Non–shielded 2,0 mm  
Shielded 1,5 mm  
Non–shielded 2,0 mm  
Shielded 1,5 mm  
Non–shielded 2,0 mm  
Shielded 1,5 mm  
Non–shielded 2,0 mm  
Shielded 1,5 mm  
Non–shielded 2,0 mm  
Shielded 1,5 mm  
Non–shielded 2,0 mm  
E2EL–C1R5E1–M3L E2EL–C1R5E2–M3L E2EL–C1R5F1–M3L E2EL–C1R5F2–M3L  
E2EL–C2ME1–M3L  
E2EL–X1R5E1–M3  
E2EL–X2ME1–M3  
E2EL–C2ME2–M3L  
E2EL–X1R5E2–M3  
E2EL–X2ME2–M3  
E2EL–C2MF1–M3L  
E2EL–X1R5F1–M3  
E2EL–X2MF1–M3  
E2EL–C2MF2–M3L  
E2EL–X1R5F2–M3  
E2EL–X2MF2–M3  
M8 /  
Plug M8  
E2EL–X1R5E1–M3L E2EL–X1R5E2–M3L E2EL–X1R5F1–M3L E2EL–X1R5F2–M3L  
E2EL–X2ME1–M3L  
E2EL–X1R5E1–M1  
E2EL–X2ME1–M1  
E2EL–X2ME2–M3L  
E2EL–X1R5E2–M1  
E2EL–X2ME2–M1  
E2EL–X2MF1–M3L  
E2EL–X1R5F1–M1  
E2EL–X2MF1–M1  
E2EL–X2MF2–M3L  
E2EL–X1R5F2–M1  
E2EL–X2MF2–M1  
M8 /  
Plug M12 46 mm  
60 mm  
E2EL–X1R5E1–M1L E2EL–X1R5E2–M1L E2EL–X1R5F1–M1L E2EL–X1R5F2–M1L  
62 mm  
E2EL–X2ME1–M1L  
E2EL–X2E1–M1  
E2EL–X2ME2–M1L  
E2EL–X2E2–M1  
E2EL–X2MF1–M1L  
E2EL–X2F1–M1  
E2EL–X2MF2–M1L  
E2EL–X2F2–M1  
M12 /  
49 mm  
60 mm  
53 mm  
80 mm  
Shielded  
Shielded  
2,0 mm  
4,0 mm  
Plug M12  
E2EL–X4E1–DM1  
E2EL–X4ME1–M1  
E2EL–X2E1–M1L  
E2EL–X4E1–DM1L  
E2EL–X4ME1–M1L  
E2EL–X5E1–M1  
E2EL–X4E2–DM1  
E2EL–X4ME2–M1  
E2EL–X2E2–M1L  
E2EL–X4E2–DM1L  
E2EL–X4ME2–M1L  
E2EL–X5E2–M1  
E2EL–X4F1–DM1  
E2EL–X4MF1–M1  
E2EL–X2F1–M1L  
E2EL–X4F1–DM1L  
E2EL–X4MF1–M1L  
E2EL–X5F1–M1  
E2EL–X4F2–DM1  
E2EL–X4MF2–M1  
E2EL–X2F2–M1L  
E2EL–X4F2–DM1L  
E2EL–X4MF2–M1L  
E2EL–X5F2–M1  
Non–shielded 4,0 mm  
Shielded  
Shielded  
2,0 mm  
4,0 mm  
Non–shielded 4,0 mm  
M18 /  
Shielded  
Shielded  
5,0 mm  
8,0 mm  
Plug M12  
E2EL–X8E1–DM1  
E2EL–X8ME1–M1  
E2EL–X5E1–M1L  
E2EL–X8E1–DM1L  
E2EL–X8ME1–M1L  
E2EL–X10E1–M1  
E2EL–X15ME1–M1  
E2EL–X10E1–M1L  
E2EL–X8E2–DM1  
E2EL–X8ME2–M1  
E2EL–X5E2–M1L  
E2EL–X8E2–DM1L  
E2EL–X8ME2–M1L  
E2EL–X10E2–M1  
E2EL–X15ME2–M1  
E2EL–X10E2–M1L  
E2EL–X8F1–DM1  
E2EL–X8MF1–M1  
E2EL–X5F1–M1L  
E2EL–X8F1–DM1L  
E2EL–X8MF1–M1L  
E2EL–X10F1–M1  
E2EL–X15MF1–M1  
E2EL–X10F1–M1L  
E2EL–X8F2–DM1  
E2EL–X8MF2–M1  
E2EL–X5F2–M1L  
E2EL–X8F2–DM1L  
E2EL–X8MF2–M1L  
E2EL–X10F2–M1  
E2EL–X15MF2–M1  
E2EL–X10F2–M1L  
Non–shielded 8,0 mm  
Shielded  
Shielded  
5,0 mm  
8,0 mm  
Non–shielded 8,0 mm  
Shielded 10,0 mm  
Non–shielded 15,0 mm  
Shielded 10,0 mm  
Non–shielded 15,0 mm  
M30 /  
55 mm  
80 mm  
Plug M12  
E2EL–X15ME1–M1L E2EL–X15ME2–M1L E2EL–X15MF1–M1L E2EL–X15MF2–M1L  
Stainless steel housing  
Output  
Diameter /  
Connection  
Length  
Mounting  
Sensing  
Distance  
NPN / NO  
NPN / NC  
PNP / NO  
PNP / NC  
M8 /Plug 54 mm  
Shielded  
2,0 mm  
E2EL–X2E1–DM3SL E2EL–X2E2–DM3SL E2EL–X2F1–DM3SL E2EL–X2F2–DM3SL  
M8  
M12 /  
Plug M12 60 mm  
M18 / 53 mm  
Plug M12 80 mm  
49 mm  
Shielded  
Shielded  
Shielded  
Shielded  
4,0 mm  
4,0 mm  
8,0 mm  
8,0 mm  
E2EL–X4E1–DM1S  
E2EL–X4E1–DM1SL E2EL–X4E2–DM1SL E2EL–X4F1–DM1SL E2EL–X4F2–DM1SL  
E2EL–X8E1–DM1S E2EL–X8E2–DM1S E2EL–X8F1–DM1S E2EL–X8F2–DM1S  
E2EL–X8E1–DM1SL E2EL–X8E2–DM1SL E2EL–X8F1–DM1SL E2EL–X8F2–DM1SL  
E2EL–X4E2–DM1S  
E2EL–X4F1–DM1S  
E2EL–X4F2–DM1S  
2
E2EL  
E2EL  
Specifications  
Brass type  
Type  
6,5  
M8  
M12  
M18  
M30  
Operating voltage  
Rated supply voltage  
Current consumption  
Sensing object  
10 to 35 VDC  
24 VDC  
max. 15 mA at 24 VDC  
Ferrous metals  
Mounting ((s)hielded,  
s
n
s
n
s
s
n
s
s
n
s
n
(n)on–shielded) (see note 1)  
Operating distance in mm  
1,5  
2,0  
1,5  
2,0  
2,0  
4,0  
4,0  
5,0  
8,0  
8,0  
10,0  
15,0  
Tolerance of operating distance  
10%  
6,5x6,5x1  
Standard target size in mm  
(L x W x H in mm, FE 37)  
8x8x1  
12x12x1  
18x18x1 24x24x1  
30x30x1 45x45x1  
Differential travel  
1 % ... 15 % of operating distance  
5,0 5,0 2,0  
Max. response frequency in kHz  
Control output Type  
0,6  
1,0  
0,5  
0,3  
0,5  
0,25  
0,15  
E2EL–... E1 type: NPN–NO  
E2 type: NPN–NC  
F1 type: PNP–NO  
F2 type: PNP–NC  
Max–Load  
Max–on–state  
200 mA  
2,5 VDC (at 200mA load current and with 2 m cable)  
Voltage drop  
Circuit protection  
Indicator  
Reverse polarity, output short–circuit  
Operating indicator (yellow LED)  
Operating: –25° to 70°C  
Ambient temperature  
Humidity  
35 to 95 % RH  
Influence of temperature  
Dielectric strength  
Electromagnetic compatibility EMC  
Vibration resistance  
10 % max. of Sn at 23°C in temperature range of –25° to 70°C  
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case  
EN 60947–5–2  
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions  
Shock  
Destruction: 300 m/s@ (approx. 30 G) for 6 times each in X, Y and Z directions  
resistance  
Enclosure  
rating  
IP 67 (EN 60947–1)  
2
Connection  
(see note 2)  
Pre–wired  
Connector  
2 m PVC–cable, 3 x  
0,14 mm@  
2 m PVC–cable, 3 x 0,25 mm  
2m PVC–cable, 3 x  
0,5 mm  
2
M8 plug  
M8 plug  
M12 plug  
M12 plug  
Weight in g  
Material  
Pre–wired  
long  
45  
50  
48  
15  
13  
75  
70  
25  
20  
115  
100  
60  
260  
200  
155  
110  
short  
43  
Connector long  
short  
10  
8
50  
Case  
Brass  
PBTP  
Sensing face  
Note: 1. For detailed mounting instruction please refer to page 11.  
2. PUR cable and different length on request.  
3
E2EL  
E2EL  
Stainless steel type  
Type  
6,5  
10 to 35 VDC  
24 VDC  
M8  
M12  
M18  
Operating voltage  
Rated supply voltage  
Current consumption  
Mounting (see note 1)  
Sensing object  
max. 15 mA at 24 VDC  
Shielded  
Ferrous metals  
2,0  
Operating distance in mm  
Tolerance of operating distance  
2,0  
4,0  
8,0  
10%  
Standard target size  
6,5x6,5x1  
8x8x1  
12x12x1  
24x24x1  
(L x W x H in mm, FE 37)  
Differential  
travel  
1 % ... 15 % of operating distance  
Max. response frequency in kHz  
Control output Type  
4,0 4,0  
0,6  
0,25  
E2EL–... E1 type: NPN–NO  
E2 type: NPN–NC  
F1 type: PNP–NO  
F2 type: PNP–NC  
Max–Load  
200 mA  
Max–on–state  
Voltage drop  
2,5 VDC (at 200mA load current and with 2 m cable)  
Circuit protection  
Indicator  
Reverse polarity, output short–circuit  
Operating indicator (yellow LED)  
Operating: –25° to 70°C  
Ambient temperature  
Humidity  
35 to 95 % RH  
Influence of temperature  
Dielectric strength  
Electromagnetic compatibility EMC  
Vibration resistance  
Shock resistance  
10 % max. of Sn at 23°C in temperature range of –25° to 70°C  
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case  
EN 60947–5–2  
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions  
Destruction: 300 m/s@ (approx. 30 G) for 6 times each in X, Y and Z directions  
IP 67 (EN 60947–1)  
Enclosure  
rating  
2
Connection  
(see note 2)  
Pre–wired  
Connector  
Pre–wired  
2 m PVC–cable, 3 x 0,14 mm@  
2 m PVC–cable, 3 x 0,25 mm  
M12 plug  
M8 plug  
Weight in g  
long  
45  
43  
50  
48  
10  
75  
70  
25  
20  
120  
105  
65  
short  
Connector long  
short  
55  
Material  
Case  
stainless steel 1.4305 / AISI 303  
PBTP  
Sensing face  
Note: 1. For detailed mounting instruction please refer to page 11.  
2. PUR cable and different length on request.  
4
E2EL  
E2EL  
Engineering Data  
Standardized characteristic for lateral approach  
1,2  
axial  
standard target  
approach  
1
0,8  
0,6  
0,4  
0,2  
0
’switch–on’ curve  
switch–off’ curve  
lateral approach  
on  
off  
–1  
–0,8  
–0,6  
–0,4  
–0,2  
0
0,2  
0,4  
0,6  
0,8  
1
lateral distance related to radius of ’active surface’ (r/ract  
)
Output Circuit Diagram and Timing Chart  
E2EL–XjEj  
NPN Output  
E2EL-XjFj  
PNP Output  
Brown 1  
Brown 1  
Load  
4,7 k  
Black 4 (or 2)  
Load  
Main  
circuit  
Main  
circuit  
Black 4 (or 2)  
Blue 3  
4,7 kΩ  
0 V  
Blue 3  
E2EL–XjEj  
NPN Output  
E2EL–XjFj  
PNP Output  
NC  
NO  
NC  
NO  
Yes  
No  
Sensing object  
Sensing object  
Yellow indicator  
Control output  
Yes  
No  
Lit  
Lit  
Yellow indicator  
Control output  
Not lit  
ON  
Not lit  
ON  
OFF  
OFF  
5
E2EL  
E2EL  
Pin Arrangement at Connector Types  
1. Connector M8 (viewed to plug pins)  
Output  
+
2. Connector M12 (viewed to plug pins)  
NO  
NC  
2 free  
1 (+)  
2 Output  
1 (+)  
3(–)  
3(–)  
4 Output  
4 free  
Dimensions  
Note: 1. All units are in millimeters unless otherwise indicated.  
2. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. Values in parentheses () are cumulative values and  
may exceed tolerance of 0.4 mm.  
3. The square j in the models represents the output configuration. Refer to Ordering Information.  
Cable Types  
E2EL–C1jR5 2M, E2EL–C2j–DS 2M  
E2EL–C2Mj 2M  
E2EL–C1R5j–L 2M, E2EL–C2j–DSL 2M  
E2EL–C2Mj–L 2M  
E2EL–X1R5j 2M, E2EL–X2j–DS 2M  
E2EL–X2Mj 2M  
E2EL–X1R5j–L 2M, E2EL–X2j–DSL 2M  
E2EL–X2Mj–L 2M  
6
E2EL  
E2EL  
E2EL–X2j 2M, E2EL–X4j–D 2M, E2EL–X4j–DS 2M  
E2EL–X4Mj 2M  
E2EL–X2j–L 2M, E2EL–X4j–DL 2M, E2EL–X4j–DSL 2M  
E2EL–X4Mj–L 2M  
E2EL–X5j 2M, E2EL–X8j–D 2M, E2EL–X8j–DS 2M  
E2EL–X5j–L 2M, E2EL–X8j–DL 2M, E2EL–X8j–DSL 2M  
E2EL–X10j 2M  
E2EL–X8Mj 2M  
E2EL–X8Mj–L 2M  
E2EL–X15Mj 2M  
E2EL–X10j–L 2M  
E2EL–X15Mj–L 2M  
7
E2EL  
E2EL  
Plug Types  
E2EL–C1R5j–M3  
E2EL–C2Mj–M3  
E2EL–C1R5j–M3L  
E2EL–C2Mj–M3L  
E2EL–X1R5j–M3  
E2EL–X2Mj–M3  
E2EL–X1R5j–M3L, E2EL–X2jDM3S  
E2EL–X2Mj–M3L  
E2EL–X1R5j–M1  
E2EL–X2Mj–M1  
E2EL–X2Mj–M1L  
E2EL–X4Mj–M1  
E2EL–X1R5j–M1L  
E2EL–X2j–M1, E2EL–X4j–DM1, E2EL–X4j–DM1S  
8
E2EL  
E2EL  
E2EL–X2j–M1L, E2EL–X4j–DM1L, E2EL–X4j–DM1SL  
E2EL–X4Mj–M1L  
E2EL–X5j–M1, E2EL–X8j–DM1, E2EL–X8j–DM1S  
E2EL–X8Mj–M1  
E2EL–X5j–M1L, E2EL–X8j–DM1L, E2EL–X8j–DM1SL  
E2EL–X8Mj–M1L  
E2EL–X10j–M1  
E2EL–X15Mj–M1  
E2EL–X10j–M1L  
E2EL–X15Mj–M1L  
9
E2EL  
E2EL  
Installation  
Caution  
Item  
Examples  
Power Supply  
Do not impose an excessive voltage on the E2EL, otherwise it  
may explode or burn.  
Do not impose 24 VAC on any E2EL model, otherwise it may  
explode or burn.  
Load short–circuit  
Do not short–circuit the load, or the E2EL may explode or burn.  
The E2EL’s short–circuit protection function is valid, if the polarity  
of the supply voltage imposed is incorrect and within the rated  
voltage range.  
Wiring  
Be sure to wire the E2EL and load correctly, otherwise it may  
explode or burn.  
Correct Use  
Installation  
If there a power or high–tension line near the cord of the Proximity  
Sensor, wire the cord through an independent metal conduit to pre-  
vent against Proximity Sensor damage or malfunctioning.  
Power Reset Time  
The Proximity Sensor is ready to operate within 100 ms after power  
issupplied. IfpowersuppliesareconnectedtotheProximitySensor  
andloadrespectively, be sure to supply power to the Proximity Sen-  
sor before supplying power to the load.  
Core Tractive Force  
Do not pull cords with the tractive force exceeding the following:  
pull force (N) = 20 x cable diameter ( mm)  
Power OFF  
Mounting  
TheProximitySensormayoutputapulsesignalwhenitisturnedoff.  
Therefore, it is recommended to turn off the load before turning off  
the Proximity Sensor.  
The Proximity Sensor must not be subjected to excessive shock  
with a ha mmer when it is installed, otherwise the Proximity Sensor  
may be damaged or lose the water–resistivity.  
Power Supply Transformer  
Environment  
Water–Resistivity  
When using a DC power supply, make sure that the DC power sup-  
plyhasaninsulatedtransformer. DonotuseaDCpowersupplywith  
an auto–transformer.  
Do not use the ProximitySensorunderwater, outdoorsorintherain.  
Sensing Object  
Operating Environment  
Metal Coating:  
Be sure to use the Proximity Sensor within operating ambient tem-  
perature range and do not use the Proximity Sensor outdoors so  
that its reliability and life expectancy can be maintained. Although  
the Proximity Sensor is water resistive, a cover to protect the Prox-  
imity Sensor from water or soluble machining oil is reco mmended  
so that its reliability and life expectancy can be maintained. Do not  
use the Proximity Sensor in an environment with chemical gas (e.  
G., strong alkaline or acid gases including nitric, chromic, and con-  
centrated sulfuric acid gases).  
The sensing distance of the Proximity Sensor vary with the metal  
coating on sensing objects.  
Wiring  
High–tension Lines  
Wiring through Metal Conduit  
10  
E2EL  
E2EL  
Item  
Examples  
Item  
AND  
The Sensors connected together must satisfy the  
following conditions:  
(serial  
connection)  
i + (N–1) x i = Upper–limit of control output of each  
Sensor  
L
V
S
– N x V = Load operating voltage  
R
N =  
No. of Sensors  
V
R
V
S
=
=
Residual voltage of each Sensor  
Supply voltage  
i =  
i =  
Current consumption of the Sensor  
Load current  
L
If the MY Relay, which operate at 24 VDC, is used as a  
load for example, a maximum of two Proximity Sensors  
can be connected to the load.  
OR  
The number of Sensors connected in parallel varies with  
the Proximity Sensor model.  
(parallel  
connection)  
Effects of Surrounding Metal  
Shielded types:  
Non–shielded types:  
Shielded types allow direct installation on metal plates in an em-  
bedded manner without performance change. A minimum distance  
Installation of non–shielded types in metal require the minimum di-  
stances according to Fig. 3.  
of 3s is required between the active surface and a metallic surface  
in front of the device. (Fig. 1).  
n
w3s w2s  
n
n
For SUS shielded types the following minimum distances are re-  
quired to avoid performance change (see Fig.2 and table below):  
Shielded SUS Types  
E2EL–C2j–DS  
Free zone  
0,5 mm  
0,5 mm  
1,0 mm  
2,0 mm  
d
w3d  
E2EL–X2j–DS  
E2EL–X4j–DjS  
E2EL–X8j–DjS  
w3s  
n
Fig.3: Non–shielded type  
Fig.1: Shielded type (except SUS)  
Freezone  
w3s  
n
Fig.2: Shielded SUS type  
11  
E2EL  
E2EL  
In the interest of product improvement, specifications are subject to change without notice.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON EUROPE B.V.  
Sensor Business Unit  
Cat. No. D093-E2-1  
Carl–Benz–Straße 4  
D–71154 NUFRINGEN (GERMANY)  
Phone: +49–70 32–811–0  
Fax:  
+49–70 32–811–199  
12  

相关型号:

E2EL-X4F2-DM1

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DM1L

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DM1S

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DM1SL

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DS

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DS2M

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DSL

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DSL2M

Cylindrical Proximity Sensor
OMRON

E2EL-X4ME1

Cylindrical Proximity Sensor
OMRON

E2EL-X4ME1-L

Cylindrical Proximity Sensor
OMRON

E2EL-X4ME1-L2M

Cylindrical Proximity Sensor
OMRON

E2EL-X4ME1-M1

Cylindrical Proximity Sensor
OMRON