Inductive Sensor, 0mm Min, 2.8mm Max, Cylindrical;
E2K-X4MF12M
型号: E2K-X4MF12M
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Inductive Sensor, 0mm Min, 2.8mm Max, Cylindrical

输出元件 传感器 换能器
文件: 总7页 (文件大小:527K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Cylindrical Proximity Sensor  
E2K-X  
CSM_E2K-X_DS_E_7_1  
General-purpose Threaded  
Capacitive Sensor  
• Product lineup with M12, M18, and M30 models.  
• Fixed sensing distance requires no sensitivity adjustment.  
Be sure to read Safety Precautions on  
page 5.  
Ordering Information  
Sensors [Refer to Dimensions on page 6.]  
Model  
Operation mode  
Appearance  
Sensing distance  
Output configuration  
NO  
NC  
DC 3-wire, NPN  
DC 3-wire, PNP  
AC 2-wire  
E2K-X4ME1 2M  
E2K-X4MF1 2M  
E2K-X4MY1 2M  
E2K-X8ME1 2M  
E2K-X8MF1 2M  
E2K-X8MY1 2M  
E2K-X15ME1 2M  
E2K-X15MF1 2M  
E2K-X15MY1 2M  
E2K-X4ME2 2M  
E2K-X4MF2 2M  
E2K-X4MY2 2M  
E2K-X8ME2 2M  
E2K-X8MF2 2M  
E2K-X8MY2 2M  
E2K-X15ME2 2M  
E2K-X15MF2 2M  
E2K-X15MY2 2M  
M12  
M18  
M30  
4 mm  
8 mm  
15 mm  
DC 3-wire, NPN  
DC 3-wire, PNP  
AC 2-wire  
Unshielded  
DC 3-wire, NPN  
DC 3-wire, PNP  
AC 2-wire  
Accessories (Order Separately)  
Mounting Brackets  
Refer to Y92@ for details.  
1
E2K-X  
Ratings and Specifications  
E2K-X4ME@,  
E2K-X4MF@,  
E2K-X4MY@  
E2K-X8ME@,  
E2K-X8MF@,  
E2K-X8MY@  
E2K-X15ME@,  
E2K-X15MF@,  
E2K-X15MY@  
Item  
Model  
Sensing distance  
Set distance *1  
4mm 10%  
0 to 2.8 mm  
8 mm 10%  
0 to 5.6 mm  
15 mm 10%  
0 to 10 mm  
Differential travel  
Detectable object  
4% to 20% of sensing distance  
Conductors and dielectrics  
Standard sensing object  
Response frequency  
Grounded metal plate: 50 × 50 × 1 mm  
E and F Models: 100 Hz, Y Models: 10 Hz  
E and F Models: 12 to 24 VDC (10 to 30 VDC)  
Power supply voltage*2  
(operating voltage range) Y Models: 100 to 220 VAC (90 to 250 VAC)  
Current consumption  
Leakage current  
E and F Models: 15 mA max.  
Y Models: 2.2 mA max. (Refer to page 4.)  
E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA  
Load current  
Control  
E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m), Y Models: Refer to Engineering Data on  
page 4.  
output  
Residual voltage  
Indicators  
E and F Models: Detection indicator (red), Y Models: Operation indicator (red)  
Operation mode  
(with sensing object  
approaching)  
E1, F1, and Y1 Models: NO  
Refer to the timing charts under I/O Circuit Diagrams on page 4 for details.  
E2, F2, and Y2 Models: NC  
E and F Models: Reverse polarity protection, Surge suppressor, load short-circuit protection, output reverse polar-  
ity protection, Y Models: Surge suppressor  
Protection circuits  
Ambient temperature  
range  
Operating/Storage: 10 to 55°C  
Operating/Storage: 25 to 70°C (with no icing or condensation)  
(with no icing or condensation)  
Ambient humidity range  
Temperature influence  
Operating/Storage: 35% to 95% (with no condensation)  
20% max. of sensing distance at 23°C in the operating temperature range  
E and F Models: 2% max. of sensing distance at rated voltage at rated voltage 20%  
Y Models: 2% max. of sensing distance at rated voltage at rated voltage 10%  
Voltage influence  
Insulation resistance  
Dielectric strength  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
E and F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case  
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case  
Vibration resistance  
Shock resistance  
Degree of protection  
Connection method  
Weight (packed state)  
Case  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s2 3 times each in X, Y, and Z directions  
IP66 (IEC), in-house standards: oil-resistant  
Pre-wired Models (Standard cable length: 2 m)  
Approx. 65 g  
Approx. 145 g  
Approx. 205 g  
Heat-resistant ABS  
Materi-  
Sensing surface  
als  
Clamping nuts  
Accessories  
Polyacetal  
Instruction manual  
*1. The above values are sensing distances for the standard sensing object. Refer to Engineering Data on page 3 for other materials.  
*2. E and F Models (DC switching models): A full-wave rectification power supply of 24 VDC 20% (average value) can be used.  
2
E2K-X  
Engineering Data (Reference Value)  
Sensing Area (Grounded Metal Plate)  
E2K-X4M  
18  
16  
E2K-X15M  
14  
Y
X
12  
10  
Standard sensing  
object Grounded  
metal plate  
50 × 50 × 1 mm  
8
6
E2K-X8M  
E2K-X4M  
4
2
0
5 20 15 10 5  
0
5
10 15 20 25  
Distance  
E2K-X4M Sensing  
Y (mm)  
E2K-X8M Sensing Head  
E2K-X15M Sensing Head  
Influence of Sensing Object Size and Material  
E2K-X4M  
E2K-X8M  
E2K-X15M  
5
10  
25  
d ×  
d
d ×  
d ×  
d
d
t = 3 mm  
t = 3 mm  
t = 3 mm  
X
X
X
Grounded metal  
Grounded metal  
4
3
2
1
20  
8
Grounded metal  
6
15  
10  
5
Non-grounded metal  
Glass  
Non-grounded metal  
Non-grounded metal  
4
2
Glass  
Phenol  
Acryl  
Phenol  
Acryl  
Glass  
Phenol  
0
10  
20  
30  
40  
50  
60  
70  
0
10  
20  
30  
40  
50  
60  
70  
0
10  
20  
30  
40  
50  
60  
70  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Sensing Object Thickness and Material vs. Sensing Distance  
E2K-X4M  
E2K-X8M  
E2K-X15M  
10  
5
25  
50 ×  
50  
t
X
4
8
20  
Grounded metal  
Grounded metal  
50 ×  
50 ×  
50  
50  
t
t
X
X
Grounded metal  
3
2
1
6
4
2
15  
10  
5
Non-grounded metal  
Glass  
Non-grounded metal  
Non-grounded metal  
Glass  
Phenol  
Phenol  
Glass  
Acryl  
Phenol  
Acryl  
0
5
10  
15  
20  
25  
5
10  
15  
20  
25  
0
0
5
10  
15  
20  
25  
Thickness of sensing object: t (mm)  
Thickness of sensing object: t (mm)  
Thickness of sensing object: t (mm)  
3
E2K-X  
Leakage Current  
E2K-X@MY  
2.0  
Residual Output Voltage  
E2K-X@MY@  
at 100 VAC  
E2K-X@MY@  
at 200 VAC  
120  
240  
Residual output voltage  
100  
Residual output voltage  
200  
160  
120  
80  
ON  
ON  
1.5  
80  
Protective resistance  
mA  
V
V
AC  
60  
power,  
50/60Hz  
V
VL  
VL  
(OFF)  
200 VAC  
100 VAC  
1.0  
40  
A
A
20  
40  
0
Residual  
Load  
Voltage  
Residual  
Load Voltage  
OFF  
100 200  
OFF  
0
3
0
100  
200  
300  
3
5
10  
20 30  
50  
5
10  
20 30  
50  
100 200  
Power supply voltage (V)  
Load current (mA)  
Load current (mA)  
I/O Circuit Diagrams  
DC 3-Wire Models (NPN)  
Operation  
mode  
Model  
Timing chart  
Output circuit  
Present  
Sensing object  
Brown  
Not present  
+V  
Load (between brown  
and black leads)  
Operate  
Reset  
High  
E2K-X4ME1  
E2K-X8ME1  
E2K-X15ME1  
NO  
NC  
Load  
*1  
Output voltage (between  
black and blue leads)  
10 kΩ  
Low  
Proximity  
Sensor  
main  
Black  
ON  
Detection indicator (red)  
*2  
OFF  
circuit  
Tr  
Present  
Sensing object  
Not present  
Operate  
Reset  
Blue  
Load (between brown  
and black leads)  
E2K-X4ME2  
E2K-X8ME2  
E2K-X15ME2  
0 V  
High  
*1. Load current: 200 mA max.  
Output voltage (between  
black and blue leads)  
Low  
ON  
*2. When a transistor is connected.  
Detection indicator (red)  
OFF  
DC 3-Wire Models (PNP)  
Operation  
mode  
Model  
Timing chart  
Output circuit  
Sensing  
object  
Present  
Not present  
Brown  
Load (between blue  
and black leads)  
Operate  
Reset  
High  
+V  
E2K-X4MF1  
E2K-X8MF1  
E2K-X15MF1  
NO  
NC  
Output voltage (between  
black and brown leads)  
*2  
Low  
Proximity  
Sensor  
Detection  
ON  
main  
circuit  
indicator (red)  
*1  
OFF  
2.2 Ω  
Black  
Blue  
Sensing  
object  
Present  
Load  
Not present  
Operate  
Reset  
3.9 kΩ  
Load (between blue  
and black leads)  
47 kΩ  
E2K-X4MF2  
E2K-X8MF2  
E2K-X15MF2  
0 V  
High  
Low  
ON  
Output voltage (between  
black and brown leads)  
*1. Load current: 200 mA max.  
*2. When a transistor is connected.  
Detection  
indicator (red)  
OFF  
AC 2-Wire Models  
Operation  
Model  
Timing chart  
Output circuit  
mode  
Sensing object  
Present  
Not present  
Operate  
Reset  
E2K-X4MY1  
E2K-X8MY1  
E2K-X15MY1  
Brown  
Blue  
Load  
Load  
NO  
Proximity  
Sensor  
main  
ON  
Operation indicator (red)  
OFF  
circuit  
Present  
Not present  
Operate  
Reset  
Sensing object  
Load  
E2K-X4MY2  
E2K-X8MY2  
E2K-X15MY2  
NC  
ON  
Operation indicator (red)  
OFF  
4
E2K-X  
Safety Precautions  
Refer to Warranty and Limitations of Liability.  
WARNING  
This product is not designed or rated for ensuring  
safety of persons either directly or indirectly.  
Do not use it for such purposes.  
Sensing Objects  
The maximum sensing distance will decrease if the sensing object is  
a non-grounded metal object or dielectric object.  
Sensing Object Material  
The E2K-X can detect almost any type of object. The sensing  
distance of the E2K-X, however, will vary with the electrical  
characteristics of the object, such as the conductance and  
inductance of the object, and the water content and capacity of the  
object. The maximum sensing distance of the E2K-X will be  
obtained if the object is made of grounded metal.  
There are objects that cannot be detected indirectly. Therefore, be  
sure to test the E2K-X in a trial operation with the objects before  
using the E2K-X in actual applications.  
Precautions for Correct Use  
Do not use this product under ambient conditions that exceed the  
ratings.  
Design  
Ambient Environment  
The Sensor may malfunction if subjected to water, oil, chemicals, or  
condensation by falsely detecting these as sensing objects.  
The E2K-X15M is highly sensitive to inductive objects and can thus  
be affected even by small quantities of water drops.  
Effects of a High-frequency Electromagnetic Field  
The E2K-X may malfunction if there is an ultrasonic washer, high-  
frequency generator, transceiver, or inverter nearby.  
For major measures, refer to Noise of Warranty and Limitations of  
Liability for Photoelectric Sensors.  
Influence of Surrounding Objects  
If the Sensor is embedded in metal, maintain at least the following  
distances between the Sensor and the metal. The Sensor is also  
affected by other materials, such as resins. Separate the Sensor from  
other materials by the same distance as for metal.  
Mounting  
Do not tighten the nut with excessive force. Always use washers when  
tightening the nuts and do not exceed the torque in the following table.  
l
m
d dia.  
n
Model  
Torque  
*
Metal object  
Be sure to ground.  
E2K-X4M  
E2K-X8M  
E2K-X15M  
0.78 N·m  
* Be sure to ground the metal object, otherwise Sensor operation will not be  
stable.  
2 N·m  
Influence of Surrounding Metal (Unit: mm)  
Miscellaneous  
Model  
Dimension  
l
d
m
8
n
Organic Solvents  
E2K-X4M  
E2K-X8M  
20  
10  
The Sensor has a case made of heat-resistant ABS resin. Be sure  
that the case is free from organic solvents or solutions containing  
organic solvents.  
50  
12  
25  
60  
E2K-X15M  
If a mounting bracket is used, be sure that at least the following  
distances are maintained.  
Influence of Surrounding Metal  
(Unit: mm)  
G
Model  
Dimension  
G
H
E2K-X4M  
E2K-X8M  
E2K-X15M  
20  
10  
30  
H
Mutual Interference  
When installing Sensors face-to-face or side-by-side, ensure that the  
minimum distances given in the following table are maintained.  
B
A
Mutual Interference  
(Unit: mm)  
Model  
Dimension  
A
B
E2K-X4M  
E2K-X8M  
E2K-X15M  
80  
70  
150  
300  
110  
200  
5
E2K-X  
(Unit: mm)  
Dimensions  
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.  
E2K-X4ME@  
E2K-X4MF@  
E2K-X4MY@  
E2K-X8ME@  
E2K-X8MF@  
E2K-X8MY@  
80  
80  
4
29 dia.  
24  
21 dia.  
17  
60  
60  
4
20  
Indicator *2  
20  
Indicator *2  
4 4  
10.7 dia.  
16.6 dia.  
*1  
*1  
M12 × 1  
Two clamping nuts  
Two washers  
M18 × 1  
Two clamping nuts  
Two washers  
*1. E and F Models: 4-dia. vinyl-insulated round cable with 3  
conductors (Conductor cross section: 0.2 mm2, Insulator  
diameter: 1.2 mm), Standard length: 2 m  
Y Models: 4-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm),  
Standard length: 2 m  
*1. E and F Models: 6-dia. vinyl-insulated round cable with 3  
conductors (Conductor cross section: 0.5 mm2, Insulator  
diameter: 1.9 mm), Standard length: 2 m  
Y Models: 6-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),  
Standard length: 2 m  
*2. E and F Models: Detection indicator (red)  
Y Models: Operation indicator (red)  
*2. E and F Models: Detection indicator (red)  
Y Models: Operation indicator (red)  
Mounting Hole Dimensions  
E2K-X15ME@  
E2K-X15MF@  
E2K-X15MY@  
Model  
F (mm)  
+0.5  
0
E2K-X4M@@  
12.5  
18.5  
30.5  
dia.  
dia.  
dia.  
+0.5  
0
E2K-X8M@@  
E2K-X15M@@  
F
+0.5  
0
80  
42 dia.  
36  
60  
10  
5
5
Indicator *2  
28.1 dia.  
*1  
M30 × 1.5  
Two clamping nuts  
Two washers  
*1. E and F Models: 6-dia. vinyl-insulated round cable with 3  
conductors (Conductor cross section: 0.5 mm2, Insulator  
diameter: 1.9 mm), Standard length: 2 m  
Y Models: 6-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),  
Standard length: 2 m  
*2. E and F Models: Detection indicator (red)  
Y Models: Operation indicator (red)  
6
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron  
disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER  
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at  
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount  
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,  
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products  
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate  
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall  
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,  
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above  
warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself  
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,  
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product  
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence  
thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate  
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our  
practice to change part numbers when published ratings or features are changed, or when significant construction changes are  
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers  
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at  
any time to confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
2014.1  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2014 All Right Reserved.  

相关型号:

E2K-X4MF22M

Inductive Sensor, 0mm Min, 2.8mm Max, Cylindrical
OMRON

E2K-X4MY1-2M

General-purpose Threaded Capacitive Sensor
OMRON

E2K-X4MY12M

Inductive Sensor, 3.6mm Min, 4.4mm Max, 200mA, Cylindrical
OMRON

E2K-X4MY2

Analog Circuit
OMRON

E2K-X4MY22M

Inductive Sensor, 3.6mm Min, 4.4mm Max, 200mA, Cylindrical
OMRON

E2K-X8ME1

Analog Circuit
OMRON

E2K-X8ME1-2M

General-purpose Threaded Capacitive Sensor
OMRON

E2K-X8MF1-2M

General-purpose Threaded Capacitive Sensor
OMRON

E2K-X8MY1-2M

General-purpose Threaded Capacitive Sensor
OMRON

E2K110B7104KB-T

Array/Network Capacitor, 16V, X7R, 0.1uF, Surface Mount, CHIP-4, CHIP
TAIYO YUDEN

E2K110B7104MB-T

Array/Network Capacitor, 16V, X7R, 0.1uF, Surface Mount, CHIP-4, CHIP
TAIYO YUDEN

E2K110B7473KB-F

ISOLATED C NETWORK, 16V, X7R, 0.047uF, SURFACE MOUNT, CHIP-4, CHIP, ROHS COMPLIANT
TAIYO YUDEN