Super-compact Proximity Sensor  
E2S  
CSM_E2S_DS_E_3_1  
Advanced Performance and Wide  
Range of Selections in a Super-  
compact Size  
• Only 5.5 × 5.5 mm with a built-in Amplifier.  
• Maximum sensing distance: 2.5 mm. Stable detection even with  
workpiece fluctuations.  
• Response frequency: 1 kHz.  
• Low current consumption.  
Be sure to read Safety Precautions on  
page 6.  
Ordering Information  
Sensors [Refer to Dimensions on page 7.]  
DC 2-Wire Models  
Model  
Appearance  
Sensing surface  
Sensing distance  
Operation mode  
NO  
E2S-W11 1M *  
NC  
Top  
Front  
Top  
E2S-W12 1M  
1.6 mm  
Unshielded  
E2S-Q11 1M *  
E2S-W21 1M *  
E2S-Q21 1M *  
E2S-Q12 1M  
E2S-W22 1M  
E2S-Q22 1M  
2.5 mm  
Front  
* Models with a different frequency are also available to prevent mutual interference. The model numbers are E2S-@@@B (e.g., E2S-W11B).  
DC 3-Wire Models  
Model  
Operation mode  
Appearance  
Sensing surface  
Sensing distance  
Output configuration  
NO  
NC  
Top  
Front  
Top  
E2S-W13 1M *  
E2S-Q13 1M *  
E2S-W23 1M *  
E2S-Q23 1M *  
E2S-W15 1M *  
E2S-Q15 1M *  
E2S-W25 1M *  
E2S-Q25 1M *  
E2S-W14 1M  
1.6 mm  
E2S-Q14 1M  
E2S-W24 1M  
E2S-Q24 1M  
E2S-W16 1M  
E2S-Q16 1M  
E2S-W26 1M  
E2S-Q26 1M  
NPN  
2.5 mm  
Unshielded  
Front  
Top  
1.6 mm  
Front  
Top  
PNP  
2.5 mm  
Front  
* Models with a different frequency are also available to prevent mutual interference. The model numbers are E2S-@@@B (e.g., E2S-W13B).  
1
E2S  
Accessories (Order Separately)  
Mounting Brackets [Refer to Dimensions on page 7.]  
Appearance  
Model  
Quantity  
Remarks  
Provided with E2S-@1@@.  
(fixed with one screw)  
Y92E-C1R6  
Provided with E2S-@2@@.  
Y92E-C2R5  
Y92E-D1R6  
Y92E-D2R5  
(fixed with one screw)  
1
For E2S-@1@@  
(fixed with two screws)  
For E2S-@2@@  
(fixed with two screws)  
Model Number Legend  
E2S- @ @ @ @  
(1)  
(2) (3) (4) (5)  
(1) Compact  
Square  
(2) Sensing Direction  
W: Top surface detection  
Q: Front surface detection  
(3) Size and Sensing Distance  
(Standard Sensing Object)  
1: 5.5 × 5.5 mm, 1.6 mm (iron)  
2: 8 × 8 mm, 2.5 mm (iron)  
(4) Output  
1: DC 2-wire NO  
2: DC 2-wire NC  
3: DC 3-wire NPN NO  
4: DC 3-wire NPN NC  
5: DC 3-wire PNP NO  
6: DC 3-wire PNP NC  
(5) Different Frequency  
Blank: Standard  
B: Different frequency  
Series  
2
E2S  
Ratings and Specifications  
DC 2-Wire Models  
Model  
E2S-W11  
E2S-W12  
E2S-Q11  
E2S-Q12  
E2S-W21  
E2S-W22  
E2S-Q21  
E2S-Q22  
Item  
Sensing surface  
Top  
Front  
Top  
Front  
Sensing distance  
Set distance  
1.6 mm 15%  
0 to 1.2 mm  
2.5 mm 15%  
0 to 1.9 mm  
Differential travel  
Detectable object  
10% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 4.)  
Standard sensing  
object  
Iron, 12 × 12 × 1 mm  
Iron, 15 × 15 × 1 mm  
Response frequency * 1 kHz min.  
Power supply voltage  
(operating voltage  
range)  
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.  
Leakage current  
Load  
0.8 mA max.  
3 to 50 mA max.  
current  
Control  
output  
Residual  
voltage  
3 V max. (under load current of 50 mA with cable length of 1 m)  
@@1 Models: Operation indicator (red), Setting indicator (green)  
@@2 Models: Operation indicator (red)  
Indicators  
Operation mode  
(with sensing object  
approaching)  
@@1 Models: NO  
@@2 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.  
* The response frequency is an average value.  
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.  
DC 3-Wire Models  
Model  
E2S-W13  
E2S-W14  
E2S-Q13  
E2S-Q14  
E2S-W23  
E2S-W24  
E2S-Q23  
E2S-Q24  
E2S-W15  
E2S-W16  
E2S-Q15  
E2S-Q16  
E2S-W25  
E2S-W26  
E2S-Q25  
E2S-Q26  
Item  
Sensing surface  
Top  
Front  
Top  
Front  
Top  
Front  
Top  
Front  
Sensing distance  
Set distance  
1.6 mm 15%  
0 to 1.2 mm  
2.5 mm 15%  
0 to 1.9 mm  
1.6 mm 15%  
0 to 1.2 mm  
2.5 mm 15%  
0 to 1.9 mm  
Differential travel  
Detectable object  
10% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 4.)  
Standard sensing  
object  
Iron, 12 × 12 × 1 mm  
Iron, 15 × 15 × 1 mm  
Iron, 12 × 12 × 1 mm  
Iron, 15 × 15 × 1 mm  
Response frequency * 1 kHz min.  
Power supply voltage  
(operating voltage  
range)  
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.  
Current consumption 13 mA max. at 24 VDC (no-load)  
Load  
current  
NPN open-collector output, 50 mA max. (30 VDC max.)  
PNP open-collector output, 50 mA max. (30 VDC max.)  
Control  
output  
Residual  
voltage  
1.0 V max. (under load current of 50 mA with cable length of 1 m)  
Indicators  
Operation indicator (orange)  
@@3 Models: NO  
@@5 Models: NO  
Operation mode  
(with sensing object  
approaching)  
@@4 Models: NC  
@@6 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on  
page 5 for details.  
Refer to the timing charts under I/O Circuit Diagrams on  
page 5 for details.  
* The response frequency is an average value.  
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.  
3
E2S  
Specifications  
Item  
Model  
E2S-@@@  
Protection circuits  
Reverse polarity protection, Surge suppressor  
Ambient temperature  
range  
Operating: 25 to 70°C (with no icing or condensation), Storage: 40 to 85°C (with no icing or condensation)  
Ambient humidity  
range  
Operating: 35% to 90% (with no condensation), Storage: 35% to 95% (with no condensation)  
Temperature influence 15% max. of sensing distance at 23°C in the temperature range of 25 to 70°C  
Voltage influence 2.5% max. of sensing distance at rated voltage in rated voltage 10% range  
Insulation resistance 50 Mmin. (at 500 VDC) between current-carrying parts and case  
Dielectric strength  
Vibration resistance  
Shock resistance  
1,000 VAC for 1 min between current-carrying parts and case  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s2 3 times each in X, Y, and Z directions  
IEC 60529 IP67  
Degree of protection  
Connection method  
Pre-wired Models (Standard cable length: 1 m)  
Weight (packed state) Approx. 10 g  
Materials Case  
Accessories  
Polyarylate resin  
Mounting Brackets  
Engineering Data (Typical)  
Sensing Area  
E2S-W1@/-W2@  
E2S-Q1@/-Q2@  
4
4
Y
Y
X
X
3
3
2
E2S-W2@  
E2S-Q2@  
E2S-Q1@  
2
E2S-W1@  
1
0
1
0
4  
3  
2  
1  
0
1
2
3
4
4  
3  
2  
1  
0
1
2
3
4
Distance Y  
(mm)  
Distance Y  
(mm)  
E2S-W1@ Sensing Head  
E2S-Q1@ Sensing Head  
E2S-W2@ Sensing Head  
E2S-Q2@ Sensing Head  
Influence of Sensing Object Size and Material  
E2S-W1@/-Q1@  
E2S-W2@/-Q2@  
2
4
d ×  
d
Iron  
X
1.5  
1
3
Iron  
SUS  
SUS  
Brass  
2
1
Brass  
Copper  
Aluminum  
t = 1 mm  
d ×  
Copper  
0.5  
d
Aluminum  
40  
X
0
10  
20  
30  
40  
50  
0
10  
20  
30  
50  
60  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
4
E2S  
I/O Circuit Diagrams  
DC 2-Wire Models  
Operation  
Model  
Timing chart  
Output circuit  
mode  
Set position  
Unstable  
sensing  
area  
Non-sensing  
area  
Stable sensing  
area  
Proximity Sensor  
Sensing  
object  
E2S-W11  
E2S-W21  
E2S-Q11  
E2S-Q21  
(%)  
100 80  
0
NO  
Rated  
sensing  
distance  
ON  
Brown  
Setting indicator (green)  
Operation indicator (red)  
OFF  
Load  
+V  
ON  
OFF  
ON  
Proximity  
Sensor  
main  
Control output  
circuit  
OFF  
Blue  
Non-sensing area  
Sensing area  
0 V  
Proximity Sensor  
Sensing  
object  
Note: The load can be connected to either  
the +V or 0 V side.  
E2S-W12  
(%)  
100  
0
E2S-W22  
E2S-Q12  
E2S-Q22  
NC  
Rated  
sensing  
distance  
ON  
Operation indicator (red)  
Control output  
OFF  
ON  
OFF  
DC 3-Wire Models  
Operation Output con-  
Model  
Timing chart  
Output circuit  
mode  
figuration  
Present  
Not present  
ON  
Sensing object  
E2S-W13  
Brown  
+V  
E2S-W23  
E2S-Q13  
E2S-Q23  
Output transistor  
(load)  
NO  
OFF  
ON  
Load  
Operation indicator  
(orange)  
Proximity  
Sensor  
main  
*
Black  
OFF  
NPN  
Output  
circuit  
Present  
Not present  
ON  
Sensing object  
E2S-W14  
E2S-W24  
E2S-Q14  
E2S-Q24  
Blue  
Output transistor  
(load)  
0 V  
NC  
OFF  
Operation indicator  
(orange)  
* Load current: 50 mA max.  
ON  
OFF  
Present  
Not present  
ON  
Sensing object  
E2S-W15  
E2S-W25  
E2S-Q15  
E2S-Q25  
Brown  
+V  
Output transistor  
(load)  
NO  
NC  
OFF  
Operation indicator  
(orange)  
ON  
Proximity  
Sensor  
main  
Black  
*
OFF  
PNP  
circuit  
Present  
Not present  
ON  
Sensing object  
Load  
E2S-W16  
E2S-W26  
E2S-Q16  
E2S-Q26  
Blue  
Output transistor  
(load)  
0 V  
OFF  
ON  
Operation indicator  
(orange)  
* Load current: 50 mA max.  
OFF  
5
E2S  
Safety Precautions  
Refer to Warranty and Limitations of Liability.  
WARNING  
This product is not designed or rated for ensuring  
safety of persons either directly or indirectly.  
Do not use it for such purposes.  
Mutual Interference  
When installing Sensors face-to-face or side-by-side, ensure that the  
minimum distances given in the following table are maintained.  
Models with Top  
Models with Front Sensing Surface  
Sensing Surface  
Precautions for Correct Use  
Do not use this product under ambient conditions that exceed the  
A
B
B
ratings.  
A
Design  
Influence of Surrounding Metal  
When mounting the Sensor within a metal panel, ensure that the  
clearances given in the following table are maintained. Failure to  
maintain these distances may cause deterioration in the  
performance of the Sensor.  
(Unit: mm)  
Model  
Distance  
A
B
E2S-W(Q)1@  
E2S-W(Q)2@  
50 (40)  
75 (50)  
20 (5.5)  
25 (8)  
Models with Top Sensing Surface  
Metal not  
exceeding height  
of Sensor surface  
Metal exceeding  
height of Sensor  
surface  
Note: Values in parentheses apply to Sensors operating at different  
frequencies.  
A
Sensing surface  
Mounting  
Sensing  
surface  
B
C
C
Proximity  
Sensor  
Tightening Torque  
Proximity  
Sensor  
For the E2S-W(Q)2@, the maximum tightening torque that should be  
applied to the mounting screws is 0.7 N·m.  
(Unit: mm)  
Model  
Distance  
A
B
8
C
2
E2S-W1@  
E2S-W2@  
0
15  
10  
Models with Front Sensing Surface  
B
B
A
C
(Unit: mm)  
Model  
Distance  
A
8
B
3
C
2
3
E2S-Q1@  
E2S-Q2@  
15  
10  
Applicable e-CON Connector Models and Manufacturers  
The companies and model number of e-CON connections that can be used with Sensor cables are listed in the following table.  
Confirm applicability when purchasing e-CON connectors for connection to Pre-wired Sensors.  
Model  
Tyco Electronics AMP K.K.  
1-1473562-4 (red)  
E2S-W@3/4  
E2S-Q@3/4  
6
E2S  
(Unit: mm)  
Dimensions  
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.  
Sensors  
E2S-W1@  
E2S-Q1@  
With Mounting Bracket Attached  
With Mounting Bracket Attached  
Indicator*  
2.6  
Sensing surface  
2
Sensing surface  
2
6.4  
5.9  
8.4  
5.5  
2.3  
6.4  
5.5  
5.9  
2.3  
8.4  
2
2
2
2
5.9  
5.9  
2.9-dia. vinyl-insulated  
round cable with 2/3  
conductors (Conductor  
cross section: 0.14 mm2,  
Insulator diameter: 0.9 mm),  
Standard length: 1 m  
Indicator*  
R1.5  
R1.5  
2.9-dia. vinyl-insulated  
round cable with 2/3  
conductors (Conductor  
cross section: 0.14 mm2,  
Insulator diameter: 0.9 mm),  
Standard length: 1 m  
22.3  
25.1  
22.3  
25.1  
Operation indicator (red),  
Setting indicator (green)  
Operation indicator (red),  
Setting indicator (green)  
*E2S-Q11@  
E2S-Q12@  
*E2S-W11@  
E2S-W12@  
Operation  
indicator (red)  
Operation indicator  
(red)  
E2S-Q13@  
E2S-Q14@  
E2S-Q15@  
E2S-Q16@  
E2S-W13@  
E2S-W14@  
E2S-W15@  
E2S-W16@  
Operation indicator  
(orange)  
Operation indicator  
(orange)  
1
19  
1
19  
E2S-W2@  
E2S-Q2@  
With Mounting Bracket Attached  
With Mounting Bracket Attached  
Indicator*  
Sensing surface  
Sensing surface  
2.5  
2.5  
10.8  
10.8  
8
2.3  
8 8.9  
2.3  
2.9-dia. vinyl-insulated  
round cable with 2/3  
conductors (Conductor  
cross section: 0.14 mm2,  
Insulator diameter: 0.9 mm),  
Standard length: 1 m  
8
3.1 dia.  
7.4  
7.8  
8
8.4  
3.1 dia.  
2.5  
Indicator*  
10.1  
2.9-dia. vinyl-insulated round cable  
with 2/3 conductors (Conductor  
cross section: 0.14 mm2, Insulator  
diameter: 0.9 mm), Standard length:  
1 m  
3.1-dia. mounting hole  
14.5  
4.1 3.6  
3.1-dia. mounting hole  
Operation indicator (red),  
Setting indicator (green)  
*E2S-Q21@  
E2S-Q22@  
*E2S-W21@  
E2S-W22@  
Operation indicator (red),  
Setting indicator (green)  
11.5  
Operation indicator (red)  
Operation indicator (red)  
7.4  
5.3  
5.3  
2
2
2
2
E2S-Q23@  
E2S-Q24@  
E2S-Q25@  
E2S-Q26@  
E2S-W23@  
E2S-W24@  
E2S-W25@  
E2S-W26@  
11.3  
23  
11.3  
15.5  
20  
Operation indicator  
(orange)  
Operation indicator  
(orange)  
18.5  
3
3
7
E2S  
Accessories (Order Separately)  
Mounting Bracket  
Y92E-C1R6  
Mounting Bracket  
Y92E-C2R5  
20.4  
2.5  
2.5  
17.2  
0.4  
8.1  
10.8  
15  
14  
2
8
11.3  
2.5  
5.3  
5.7  
2.3  
2
2
1.5  
5.6  
Two, R0.7  
2.3  
2.4  
5.9  
0.4  
3.1 dia.  
11.3  
6.4  
8.4  
2
2
R1.2  
R1.5  
Two, R1.2  
0.4  
Material: Stainless steel  
(SUS304)  
Material: Stainless steel  
(SUS304)  
1.1 1.3  
3.5  
Mounting Hole Dimensions  
9.5  
*Provided with E2S-@1@@.  
* Provided with E2S-@2@@.  
2.31.5  
2.4 dia.  
(depth: 2 min.)  
2.4 dia. (depth: 3 min.)  
M3 dia. (depth: 8 min.)  
Mounting Hole Dimensions  
3
11.5  
17.5  
M3  
Mounting Bracket  
Y92E-D1R6  
Mounting Bracket  
Y92E-D2R5  
22.4  
16  
Two, R1.6  
Four, R1  
3.2  
3.2  
1
1
5
7.8  
3.2  
7
3
3
R1.6  
17.4  
5.6  
Mounting Hole  
Dimensions  
Two, M3  
0.9  
Mounting Hole  
Dimensions  
Four, R1  
0.2  
3.2  
R1.6  
Two, R1.6  
8
7
Two, M3  
Material: Stainless steel  
(SUS304)  
Material: Stainless steel  
(SUS304)  
5
5.3  
0.3  
17  
5
8
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

E2S-Q13B

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q14

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q141M

Inductive Sensor, 1.6mm Min, 1.6mm Max, 50mA, Rectangular
OMRON

E2S-Q14B

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q15

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q151M

Inductive Sensor, 1.6mm Min, 1.6mm Max, 50mA, Rectangular
OMRON

E2S-Q15B

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q16

Analog Circuit
OMRON

E2S-Q161M

Inductive Sensor, 1.6mm Min, 1.6mm Max, 50mA, Rectangular
OMRON

E2S-Q16B

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q21

Analog Circuit
OMRON

E2S-Q211M

Inductive Sensor, 1.6mm Min, 1.6mm Max, 3-50mA, Rectangular
OMRON