E2S-Q26B [OMRON]
Miniature Square Inductive Proximity Sensor;型号: | E2S-Q26B |
厂家: | OMRON ELECTRONICS LLC |
描述: | Miniature Square Inductive Proximity Sensor |
文件: | 总8页 (文件大小:545K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Miniature Square Inductive Proximity Sensor
E2S
• Miniature housing with long sensing ranges
• Front ans side facing sensing surfaces
Features
Ultra small housing
High-Speed Response
5.5 mm
1 kHz
IP67
The 5.5 mm x 5.5 mm type permits smaller, space-saving ma-
chines and devices.
Environment-Resistant Types
Full sealing structure housing, degree of protection IEC60529 IP67.
Adopted for more compact machines and devices.
Low Current Consumption (Com-
pared to conventional models)
1/20
5.5mm
Significantly lower current consumption. The 0.8 mA (for 24
VDC) leakage current for the DC 2-wire type has a ratio of ap-
proximately 1/20 compared to the conventional DC 3-wire
type. Optimum solution for multiple-sensor applications such
as cam switches.
E2S
D-61
Ordering Information
Sensors
DC 2-wire Models
Model
Shape
Sensing surface
Sensing distance
1.6mm
Operating status
NO
NC
Front face
End face
Front face
End face
E2S-W11 *
E2S-W12
Unshielded
E2S-Q11 *
E2S-W21 *
E2S-Q21 *
E2S-Q12
E2S-W22
E2S-Q22
2.5mm
* Models with different response frequency are available (NO only). These model numbers take the form E2S-###B (e.g., E2S-W11B)
DC 3-wire Models
Model
Operating status
Output
specifications
Shape
Sensing surface
Sensing distance
1.6mm
NO
NC
Front face
End face
Front face
End face
Front face
End face
Front face
End face
E2S-W13*
E2S-Q13*
E2S-W23*
E2S-Q23*
E2S-W15*
E2S-Q15*
E2S-W25*
E2S-Q25*
E2S-W14
E2S-Q14
E2S-W24
E2S-Q24
E2S-W16
E2S-Q16
E2S-W26
E2S-Q26
NPN
PNP
2.5mm
Unshielded
1.6mm
2.5mm
* Models with different response frequency are available (NO only). These model numbers take the form E2S-###B (e.g., E2S-W11B)
Accessories (Order Separately)
Mounting Brackets
Shape
Model
Quantity
Remarks
Y92E-C1R6
Provided with E2S-#1##
Y92E-C2R5
Y92E-D1R6
Y92E-D2R5
Provided with E2S-#2##
1
---
---
Nomenclature
E2S - # # # #
A
B C D E
A Compact square
B Sensing direction
W: Front face sensing
Q: End face sensing
C Size and sensing distance
(standard sensing object)
1: 5.5 x 5.5 mm, 1.6 mm (iron)
2: 8 x 8 mm, 2.5 mm (iron)
D Output
E Different response
frequency
series
1: DC 2-wire NO
2: DC 2-wire NC
No: Standard
3: DC 3-wire NPN NO
4: DC 3-wire NPN NC
5: DC 3-wire PNP NO
6: DC 3-wire PNP NC
B: Different response
frequency
D-62
Inductive Sensors
Rating/Performance
DC 2-wire Models
Model
E2S-W11
E2S-W12
E2S-Q11
E2S-Q12
E2S-W21
E2S-W22
E2S-Q21
E2S-Q22
Item
Sensing surface
Sensing distance
Setting distance
Differential distance
Sensing object
Front face
1.6 mm 10%
End face
Front face
End face
2.5 mm 15%
0 to 1.9 mm
0 to 1.2 mm
10% max.
Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing
object
Iron, 12 x 12 x 1 mm
Iron, 15 x 15 x 1 mm
Response frequency
1 kHz min.
Rated supply voltage
(operating voltage)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
Leakage current
Switching
capacity
3 to 50 mA DC max.
Control
output
Residual
voltage
3 V max. (under load current of 50 mA with cable length of 1 m)
##1 models: Operation indicator(red LED), Operation set indicator(green LED)
##2 models: Operation indicator(red LED)
Indicator lamp
Operating status
(with sensing object
approaching)
##1 models: NO
##2 models: NC
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the
size of the sensing object and the sensing distance set is half of the maximum sensing distance.
DC 3-wire Models
Model
E2S-W13
E2S-W14
E2S-Q13
E2S-Q14
E2S-W23
E2S-W24
E2S-Q23
E2S-Q24
E2S-W15
E2S-W16
E2S-Q15
E2S-Q16
E2S-W25
E2S-W26
E2S-Q25
E2S-Q26
Item
Sensing surface
Front face
End face
Front face
End face
Front face
End face
Front face
End face
Sensing distance
Setting distance
Differential distance
Sensing object
1.6 mm 10%
0 to 1.2 mm
10% max.
2.5 mm 15%
0 to 1.9 mm
1.6 mm 10%
0 to 1.2 mm
2.5 mm 15%
0 to 1.9 mm
Ferrous metal
Standard sensing
object
Iron, 12 x 12 x 1 mm
1 kHz min.
Iron, 15 x 15 x 1 mm
Iron, 12 x 12 x 1 mm
Iron, 15 x 15 x 1 mm
Response frequency
Rated supply voltage
(operating voltage)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 13 mA max. (24 VDC, unload)
Switching
capacity
NPN open collector 100 mA max. (30 VDC max.)
PNP open collector 50 mA max. (30 VDC max.)
Control
output
Residual
voltage
1 V max. (under load current of 50 mA with cable length of 1 m)
Indicator lamp
Operation indicator (orange)
Operating status
(with sensing object
approaching)
##3 models: NO
##4 models: NC
##5 models: NO
##6 models: NC
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the
size of the sensing object and the sensing distance set is half of the maximum sensing distance.
E2S
D-63
Specifications
Item
Model
E2S-###
Protective circuits
Reverse polarity connection and surge absorber
Ambient temperature Operating: -25°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation)
Ambient humidity Operating: 35% to 90%RH, Storage: 35% to 95%RH (with no condensation)
Temperature influence 15% max. of sensing distance at 23°C in temperature range of -25°C to 70°C
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Protective structure
Connection method
2.5% max. of sensing distance within a range of 10% of rated supply voltage
50 M min. (at 500 VDC) between energized parts and case
1,000 VAC for 1 min between energized parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
IEC60529 IP67
Pre-wired models (Standard length: 3 m)
Weight (Packed state) Approx. 10 g
Material Case
Accessories
Polyarylate
Mounting Brackets
Characteristic data (typical)
Sensing Distance vs. Sensing Object
E2S-W1#/-Q1#
E2S-W2#/-Q2#
2
4
#d
t=1mm
Iron
X
X
1.5
1
3
2
1
SUS
Brass
Iron
SUS
Brass
Copper
Aluminum
#d
0.5
Copper
t=1mm
Aluminum
40
X
0
10
20
30
40
50
0
10
20
30
50
60
Side length of sensing object d (mm)
Side length of sensing object d (mm)
D-64
Inductive Sensors
Output Circuit Diagram
DC 2-wire Models
Operating
Model
Timing chart
Output circuit
status
Setting position
Stable sensing zone
Unstable
Sensing
zone
Non-sensing zone
Proximity Sensor
Sensing
object
E2S-W11
E2S-W21
E2S-Q11
E2S-Q21
(%)
100 80
0
NO
Rated sensing
distance
ON
Setting indicator (green)
Operation indicator (red)
Control output
OFF
Brown
Load
+V
0V
ON
OFF
ON
Main
circuit
OFF
Blue
Non-sensing zone
Sensing zone
Proximity Sensor
Sensing
object
(%)
100
0
E2S-W12
E2S-W22
E2S-Q12
E2S-Q22
NC
Non-sensing
zone
ON
Operation indicator (red)
Control output
OFF
ON
OFF
DC 3-wire Models
Output
specifications
Operating
status
Model
Timing chart
Yes
Output circuit
Sensing object
No
ON
E2S-W13
E2S-W23
E2S-Q13
E2S-Q23
Brown
Output transistor (load)
+V
NO
NC
OFF
ON
Load
Operation indicator (orange)
OFF
*
Black
Main
circuit
NPN
Output
Yes
No
Sensing object
E2S-W14
E2S-W24
E2S-Q14
E2S-Q24
ON
Output transistor (load)
Blue
0V
OFF
ON
Operation indicator (orange)
* Maximum load current: 50 mA
OFF
Yes
No
Sensing object
E2S-W15
E2S-W25
E2S-Q15
E2S-Q25
Brown
ON
Output transistor (load)
+V
NO
OFF
ON
Operation indicator (orange)
OFF
Black
*
Main
circuit
PNP
Load
Yes
No
Sensing object
Blue
E2S-W16
E2S-W26
E2S-Q16
E2S-Q26
0V
ON
Output transistor (load)
NC
OFF
ON
* Maximum load current: 50 mA
Operation indicator (orange)
OFF
E2S
D-65
Precautions
Correct Use
Design
Effects of Surrounding Metal
Mutual Interference
• Provide a minimum distance between the Sensor and the
surrounding metal as shown in the table below.
• Front Surface Sensing Type (Not exceeding the sensor
head height)
If more than one Sensor is located face to face or in parallel,
be sure to maintain enough space between adjacent Sensors
to suppress mutual interference as provided in the following
diagram,.
• Front Surface Sens-
• End Surface Sensing Type
Sensing surface
A
ing Type
Sensing
surface
B
C
C
B
A
B
Proximity Sensor
Proximity Sensor
A
(Unit: mm)
Model
Length
A
0
B
8
C
E2S-W1#
E2S-W2#
2
15
10
(Unit: mm)
• End Surface Sensing Type
Model
Length
A
B
E2S-W(Q)1#
E2S-W1#
50 (40)
75 (50)
20 (5.5)
25 (8)
B
B
A
Note: The above values in parentheses are applicable when using two sensors
with different frequencies.
C
Mounting
Tightening torgues
(Unit: mm)
Model
Length
A
8
B
3
C
2
3
Do not tighten the E2S-W(Q)2#mounting screws to a torque
exceeding 0.7 Nm.
E2S-Q1#
E2S-Q2#
15
10
D-66
Inductive Sensors
Dimensions (Unit: mm)
Sensors
E2S-W1#
E2S-Q1#
If mounting bracket is attached
If mounting bracket is attached
Indicator *
2.6
Sensing surface
6.4
2
Sensing surface
2
6.4
5.9
5.5
2.3
5.9
5.5
2.3
8.4
8.4
2
2
5.9
2
2
5.9
R1.5
2.9 dia. vinyl-insulated
round cable, 2 / 3 cores
(conductor sectional
area: 0.14mm2, Insulator
diameter: 0.9 dia.) ;
Indicator *
R1.5
22.3
25.1
2.9 dia. vinyl-insulated
round cable, 2 / 3 cores
(conductor sectional area:
22.3
25.1
Operation indicator (red)
Setting indicator (green)
* E2S-Q11#
E2S-Q12#
Operation indicator (red)
Setting indicator (green)
* E2S-W11#
0.14mm2, Insulator diameter: 0.9 dia.) ;
standard length: 1 m
Operation indicator (red)
E2S-W12#
Operation indicator (red)
standard length: 1 m
E2S-Q13#
E2S-Q14#
E2S-Q15#
E2S-Q16#
E2S-W13#
E2S-W14#
E2S-W15#
E2S-W16#
Operation indicator (red)
Operation indicator (orange)
1
19
1
19
E2S-Q2#
E2S-W2#
If mounting bracket is attached
If mounting bracket is attached
Indicator *
Sensing surface
2.5
Sensing surface
10.8
2.5
10.8
2.3
8
8
8.9
2.3
7.4
7.8
8
10.1
2.9 dia. vinyl-insulated round
cable, 2 / 3 cores (conductor
sectional area: 0.14mm2,
Insulator diameter: 0.9 dia.)
; standard length: 1 m
3.1 dia.
3.1 dia.
8
8.4
2.5
2.9 dia. vinyl-insulated round cable,
2 / 3 cores (conductor sectional area:
0.14m‡u, Insulator diameter: 0.9 dia.) ;
standard length: 1 m
Indicator *
3.1 dia. mounting holes
14.5
4.1 3.6
Operation indicator (red)
Setting indicator (green)
*E2S-W21#
E2S-W22#
3.1 dia. mounting holes
Operation indicator (red)
Setting indicator (green)
*E2S-Q21#
E2S-Q22#
11.5
Operation indicator (red)
Operation indicator (red)
7.4
5.3
5.3
2
2
E2S-W23#
E2S-W24#
E2S-W25#
E2S-W26#
2
2
E2S-Q23#
E2S-Q24#
E2S-Q25#
E2S-Q26#
11.3
15.5
20
Operation indicator (orange)
11.3
Operation indicator (orange)
18.5
3
3
23
Accessories (Order Separately*)
Mounting Brackets
Y92E-C1R6
Mounting Brackets
Y92E-C2R5
20.4
17.2
2.5
2.5
0.4
15
10.8
14
2
8
11.3
2.5
5.3
2
5.7
8.1
2.3
2
Two, R0.7
2.3
1.5
2.4
5.9
5.6
0.4
3.1 dia.
11.3
6.4
8.4
2
R1.2
Two, R1.2
R1.5
2.31.5
2
Material: Stainless
steel (SUS304)
Material: Stainless
steel (SUS304)
0.4
1.1
1.3 3.5
* Provided with
E2S-#2#
* Provided with
9.5
Mounting Holes
E2S-#1##
Mounting Holes
dia. 2.4 screw
depth 3 min.
2.4 dia. screw
depth 2 min.
M3 screw depth 8 min.
3
11.5
17.5
M3
Mounting BracketsTwo, R1.6
Mounting Brackets
Y92E-D2R5
22.4
16
Four, R1
3.2
3.2
Y92E-D1R6
1
1
5
7
7.8
3.2
3
3
R1.6
17.4
0.9
Four, R1
3.2
R1.6
Two, R1.6
Mounting Holes
Two, M3
Mounting Holes
Two, M3
5.6
5.3
8
7
Material: Stainless
steel (SUS304)
0.3
Material: Stainless
steel (SUS304)
5
0.2
12
5
17
E2S
D-67
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. E902-E2-02-X
D-68