Photoelectric Sensors
E3F2
Threaded Cylindrical Photoelectric
Sensors with Built-in Amplifier for Use
as an Optical Proximity Switch
• M18 DIN-sized cylindrical housing
• Housing materials: plastic, nickel plated brass and stainless
steel
• Axial and radial types (with integrated 90°-optics)
• Enclosure rating IP67
• DC switching types with connectors for easy maintenance
• Full metal plug-in type
• Sensing distance separate types: 7 m, 10 m
• Retroreflective polarizing types: 2 m, 4 m
• Background suppression type: 10 cm
• Long detection distance (0.3 m, 1 m) with sensitivity adjust-
er for diffuse type
• Wide-beam characteristics (10 cm) for diffuse type
• Wide operating voltage range
(10 to 30 VDC or 24 to 240 VAC)
• Short-circuit and reverse connection protection
(DC switching type)
• UL and CSA approved (AC switching types)
• UL listed (DC switching types)
Photoelectric Sensors E3F2
1
Ordering Information
■ DC-Switching Models
Housing Material: Plastic
Note: Shaded models are normally stocked.
Sensing method
Appearance
Connection
method
Sensing
distance
Model
PNP output
E3F2-7B4
NPN output
Multi purpose
pre-wired
7 m
E3F2-7C4
M12 connector
pre-wired
E3F2-7B4-P1
E3F2-10B4
E3F2-7C4-P1
E3F2-10C4
Through-beam
- precision detection (*1)
- test input
10 m
axial
axial
M12 connector
pre-wired
E3F2-10B4-P1
E3F2-R2B4
E3F2-10C4-P1
E3F2-R2C4
0.1 - 2 m(*2)
0.1 - 4 m(*3)
Non-polarizing
(without MSR function)
M12 connector
pre-wired
E3F2-R2B4-P1
E3F2-R4B4F
E3F2-R4B4F-P1
E3F2-R4B4
E3F2-R2C4-P1
E3F2-R4C4F
E3F2-R4C4F-P1
E3F2-R4C4
Polarizing
(with MSR
function)
Fixed
sensitivity
Retro-
reflective
(incl. reflector
E39-R1 or
E39-R1S)
M12 connector
pre-wired
Adjustable
sensitivity
M12 connector
pre-wired
E3F2-R4B4-P1
E3F2-R2RB41
E3F2-R2RB41-P1
E3F2-R4C4-P1
E3F2-R2RC41
E3F2-R2RC41-P1
0.1 - 2 m(*2)
Polarizing
(with MSR function)
M12 connector
radial
axial
Fixed sensitivity
Wide-beam characteristics
pre-wired
0.1 m
0.3 m
1 m
E3F2-DS10B4-N
E3F2-DS10B4-P1
E3F2-DS30B4
E3F2-DS10C4-N
E3F2-DS10C4-P1
E3F2-DS30C4
M12 connector
pre-wired
Adjustable sensitivity
M12 connector
pre-wired
E3F2-DS30B4-P1
E3F2-D1B4
E3F2-DS30C4-P1
E3F2-D1C4
Diffuse
reflective
M12 connector
pre-wired
E3F2-D1B4-P1
E3F2-DS30B41
E3F2-DS30B41-P1
E3F2-D1C4-P1
E3F2-DS30C41
E3F2-DS30C41-P1
Adjustable sensitivity
Fixed sensing distance
0.3 m
M12 connector
radial
axial
pre-wired
10 cm
E3F2-LS10B4
E3F2-LS10C4
Background
suppression
M12 connector
E3F2-LS10B4-P1
E3F2-LS10C4-P1
*1)with slit E39-ES18
*2)with reflector E39-R1
*3)with reflector E39-R1S
Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adding the
length of the cable (e.g. E3F2-R2RB4 2M or E3F2-R2RB4 5M). For other cable length please contact your OMRON sales representative.
2
Photoelectric Sensors E3F2
■ Housing material: Metal (Nickel plated brass)
Note: Shaded models are normally stocked.
Sensing method
Appearance
Connection
method
Sensing
distance
Model
PNP output
E3F2-7B4-M
NPN output
E3F2-7C4-M
Through-beam Multi purpose
pre-wired
7 m
M12 connector
pre-wired
E3F2-7B4-M1-M
E3F2-10B4-M
E3F2-7C4-M1-M
E3F2-10C4-M
- precision detection
- test input
10 m
axial
M12 connector
E3F2-10B4-M1-M
E3F2-10C4-M1-M
0.1 - 2 m(*1)
0.1 - 4 m(*2)
Retro-
reflective
(incl. reflector function)
E39-R1)
Polarizing
(with MSR
Fixed
sensitivity
pre-wired
E3F2-R2RB4-M
E3F2-R2RB4-M1-M
E3F2-R4B4F-M
E3F2-R4B4F-M1-M
E3F2-R4B4-M
E3F2-R2RC4-M
E3F2-R2RC4-M1-M
E3F2-R4C4F-M
E3F2-R4C4F-M1-M
E3F2-R4C4-M
M12 connector
pre-wired
M12 connector
pre-wired
axial
Adjustable
sensitivity
M12 connector
pre-wired
E3F2-R4B4-M1-M
E3F2-R2RB41-M
E3F2-R4C4-M1-M
E3F2-R2RC41-M
0.1 - 2 m(*1)
Polarizing
(with MSR function)
radial
axial
Diffuse
reflective
Fixed sensing distance
Wide-beam characteristics
pre-wired
0.1 m
0.3 m
1 m
E3F2-DS10B4-M
E3F2-DS10B4-M1-M
E3F2-DS30B4-M
E3F2-DS30B4-M1-M
E3F2-D1B4-M
E3F2-DS10C4-M
E3F2-DS10C4-M1-M
E3F2-DS30C4-M
E3F2-DS30C4-M1-M
E3F2-D1C4-M
M12 connector
pre-wired
Adjustable sensing
distance
M12 connector
pre-wired
M12 connector
pre-wired
E3F2-D1B4-M1-M
E3F2-DS30B41-M
E3F2-DS30B41-M1-M
E3F2-D1C4-M1-M
E3F2-DS30C41-M
E3F2-DS30C41-M1-M
Adjustable sensing
distance
0.3 m
M12 connector
radial
axial
Background
suppression
Fixed sensing
distance
pre-wired
10 cm
E3F2-LS10B4-M
E3F2-LS10C4-M
M12 connector
E3F2-LS10B4-M1-M
E3F2-LS10C4-M1-M
*1)with reflector E39-R1
*2)with reflector E39-R1S
Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adding the
length of the cable (e.g. E3F2-R2RB4 2M or E3F2-R2RB4 5M). For other cable length please contact your OMRON sales representative.
Photoelectric Sensors E3F2
3
■ Housing material: Metal (Stainless steel)
Note: Shaded models are normally stocked.
Sensing method
Through-beam
Appearance
Connection
method
Sensing
distance
Model
PNP output
E3F2-7B4-S
E3F2-7B4-M1-S
NPN output
E3F2-7C4-S
pre-wired
7 m
M12 connector
E3F2-7C4-M1-S
axial
axial
Retro-
reflective
(incl. reflector
E39-R1)
Polarizing
(with MSR function)
pre-wired
0.1 - 2 m E3F2-R2RB4-S
E3F2-R2RC4-S
(with
reflector
E39-R1)
0.1 m
M12 connector
E3F2-R2RB4-M1-S
E3F2-R2RC4-M1-S
Diffuse
reflective
Fixed sensitivity
Wide-beam characteristics
pre-wired
E3F2-DS10B4-S
E3F2-DS10C4-S
M12 connector
pre-wired
E3F2-DS10B4-M1-S
E3F2-DS30B4-S
E3F2-DS10C4-M1-S
E3F2-DS30C4-S
Adjustable sensitivity
0.3 m
axial
M12 connector
E3F2-DS30B4-M1-S
E3F2-DS30C4-M1-S
Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adding the
length of the cable (e.g. E3F2-R2RB4-S 2M or E3F2-R2RB4-S 5M). For other cable length please contact your OMRON sales representa-
tive.
■ AC-Switching Models
Housing material: Plastic
Note: Shaded models are normally stocked.
Sensing method
Through-beam
Appearance
Connection
method
Sensing
distance
Model
Light-ON
E3F2-3Z1
Dark-ON
E3F2-3Z2
pre-wired
3 m
axial
axial
Retro-
reflective
(incl. reflector
E39-R1)
Non-polarizing
(without MSR function)
pre-wired
0.1 - 2 m E3F2-R2Z1
(with
reflector
E3F2-R2Z2
E39-R1)
Diffuse
reflective
Fixed sensing distance
Wide-beam characteristics
pre-wired
0.1 m
E3F2-DS10Z1-N
E3F2-DS10Z2-N
axial
Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adding the
length of the cable (e.g. E3F2-R2Z1 2M or E3F2-R2Z1 5M). For other cable length please contact your OMRON sales representative.
4
Photoelectric Sensors E3F2
■ Accessories (Order Separately)
Note: Shaded models are normally stocked.
Name
Sensing distance (typical) [1.]
0.1 - 3.7 m (axial)
0.1 - 2.4 m (radial)
0.1 - 4.3 m (axial)
0.1 - 4.2 m (axial)
0.1 - 2.7 m (radial)
Model
Remark
Reflectors
E39-R1
60 x 40 mm (included in
some models)
E39-R1S
E39-R7
for E3F2-R4
84 mm
0.1 - 5.3 m (axial)
0.1 - 3.1 m (radial)
E39-R8
100 x 100 mm
0.1 - 4.3 m (axial)
E39-R40
E39-RSA
E39-RSB
E39-RS3
E39-F31
80 x 80 mm
35 x 10 mm
35 x 40 mm
80 x 70 mm
Tape Reflectors
Lens Cap
Mounting Bracket
Y92E-B18
Y92E-G18
E39-ES18
screw mount
quick access mounting
Slit
for E3F2-10@ - precision
detection
For detailed information about Accessories, refer to the main chapter “Accessories” at the end of the document.
Note: 1. Typical sensing distance corresponds to 80% of the max. sensing distance. For details, please refer to “Engineering Data”.
■ Sensor I/O Connectors
Note: Shaded models are normally stocked.
Cord
Shape
Cable type
Four-wire type
Model
Standard
2 m
5 m
2 m
5 m
2 m
5 m
2 m
5 m
XS2F-D421-D80-A
Straight
XS2F-D421-G80-A
XS2F-D422-D80-A
XS2F-D422-G80-A
XS2F-D421-D80-R
XS2F-D421-G80-R
XS2F-D422-D80-R
XS2F-D422-G80-R
L-shaped
Straight
Vibration-proof
robot cable
L-shaped
Photoelectric Sensors E3F2
5
Specifications
■ Ratings / Characteristics of DC Switching Models
Item
E3F2-7@
E3F2-10@ E3F2-R2@4-@ E3F2-R2R@ E3F2-R4@-@ E3F2-DS10@ E3F2-DS30@
E3F2-
D1@4-@
E3F2-
LS10@4-@
Sensing method
Through-beam
Retroreflective
Non-
Diffuse reflective
- multi
purpose
- Precision
Polarizing
Wide beam
characteristic
Adjustable sensing distance Background
suppression
detection [6.] polarizing
- test input
Power supply voltage
Current consumption
10 to 30 V DC 12 to 24 V DC 10 to 30 V DC
50 mA max.
25 mA max.
0.1 - 2 m
30 mA max.
25 mA max.
0.1 m
30 mA max.
Rated sensing distance 7 m
[1.]
10 m
0.1 - 4 m
0.3 m
1 m
0.1 m
(with reflector E39-R1)
(with reflector (5 x 5 cm white (10 x 10 cm
(30 x 30 cm
white
(10 x 10 cm
white
E39-R1S)
mat paper)
white
mat paper)
mat paper)
mat paper)
Typical sensing distance
for different reflector
types (ref. to accesso-
ries) [2.]
–
E39-R1: 4.0 m E39-R1:
E39-R1S:4.3 m –
E39-R7: 4.8 m
E39-R8: 5.6 m
E39-R40: 4.3 m
4.2 m
E39-RS3: 2 m
axial
3.7 m
E39-R7: 4.5 m
E39-R8: 5.3 m
radial 2.4 m
E39-R7:
axial
radial 2.7 m
E39-R8:
axial
5.3 m
radial 3.1 m
Standard object
Directional angle
Opaque: 11 mm dia. min.
Opaque: 56 mm dia. min.
–
–
3° to 20°
–
Differential travel
(hysteresis)
20% max.
5% max
3%
Black/white error
Response time
–
Operation and Reset: 2.5 ms max.
1 ms max
2.5 ms max.
50 ms
1 ms max.
100 ms
Control output
Transistor (open collector), load current: 100 mA max. (residual voltage: 2 V max.)
Power reset time
Ambient illumination
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Enclosure ratings
Light source
50 ms
100 ms max.
Incandescent lamp: 3000 lx max. / Sunlight: 10000 lx max.
Operating: -25 to 55 °C / Storage: -30 to 70 °C (with no icing or condensation)
Operating: 35% to 85% / Storage: 35% to 95% (without condensation)
20 MΩ min. at 500 V DC between energized parts and case
1000 VAC max., 50 / 60 Hz for 1 min between energized parts and case
10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z)
Destruction: 500 m/s2 each direction (X, Y, Z)
IP67 [3.]; NEMA 1, 2, 4
Infrared LED (880 nm/850 nm)
Red LED (660 nm)
Infrared LED (880 nm)
Red LED
(660 nm)
Indicators
Light incident Output
/ power indi- (orange) /
cator for light light emission
source (red) (red)
Light incident / power
indicator for light source (red)
Light incident
(red) /
stability (green)
Light incident / power indicator Light incident Output
for light source (red)
(red) /
indicator
stability
(green)
(orange) / sta-
bility (green)
Sensitivity adjustment
Fixed
Fixed /
Adjustable
Fixed
Adjustable
Fixed
Connection method
Test Input
2 m, 5 m pre-wired cable (PVC, dia. 4 mm (18 / 0.12) [4.]) or M12-connector
[7.]
Light-ON or Dark-ON selectable by wiring
–
–
Operation mode
Weight (approx.)
Plastic pre-wired (2 m) 120 g
case
60 g
20 g
90 g
50 g
connector
40 g
Metal pre-wired (2 m) 180 g
case
connector
Circuit protection
Housing materials
120 g
Output short-circuit and power supply reverse polarity
Plastic (case: ABS; lens: PMMA)
Nickel brass Nickel brass
–
–
Nickel brass Nickel brass
Nickel brass
Nickel brass
Nickel brass Nickel brass
Stainless
steel [5.]
–
Stainless
steel [5.]
–
Stainless
steel [5.]
Stainless
steel [5.]
–
–
Note: 1. For stable sensing distance in detail, please refer to “Engineering Data”
2. Typical sensing distance corresponds to 80% of the max. sensing distance.
3. The enclosure rating IP67 of OMRON internal standards correspond to stricter test requirements than the standard IEC 60529 (refer to
chapter “Precautions”)
4. For other cable materials (e.g. PUR) please contact your OMRON sales representative.
5. Material-specification for stainless steel housing case: 1.4305 (W.-No.), 303 (AISI), 2346 (SS). For other stainless steel materials please
contact your OMRON sales representative.
6. with slit E39-ES18
7. PNP models -B4: VCC to VCC -2.5 V: Emitting OFF (Source current: 3 mA max.) / Open or 0 to 2.5 V: Emitting ON (Leakage current: 0.1
mA max.)
NPN models -C4: 0 to 2.5 V: Emitting OFF (Source current: 3 mA max.) / Open or Vcc to Vcc -2.5 V: Emitting ON (Leakage current: 0.1
mA max.)
6
Photoelectric Sensors E3F2
■ Ratings / Characteristics of AC Switching Models
Item
E3F2-3Z1
E3F2-3Z2
E3F2-R2Z1
E3F2-R2Z2
E3F2-DS10Z1
E3F2-DS10Z2
Sensing method
Through-beam
Non-polarizing Retroreflective
Diffuse reflective
(wide-beam characteristic)
Power supply voltage
Current consumption
Rated sensing distance[1.]
24 to 240 VAC 10%, 50 / 60 Hz
10 mA max.
3 m
5 mA max.
0.1 - 2 m
(with reflector E39-R1)
0.1 m
(5 x 5 cm white mat paper)
Typical sensing distance for dif-
ferent reflector types [2.]
–
E39-R1: 3,4 m
E39-R7: 3,9 m
E39-R8: 5,2 m
–
Detectable object
Directional angle
Differential travel
Response time
Opaque object: 11 mm min.
Opaque object: 56 mm min.
Opaque objects
3° to 20°
–
–
20% max.
30 ms max.
Control output
AC solid state (SCR) 200 mA max.; residual voltage: 5 V max. at 200 mA
100 ms
Power reset time
Ambient illumination
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Enclosure rating
Light source
Incandescent lamp: 3000 lx max. Sunlight: 10000 lx max.
Operating: -25 to 55 °C / Storage: -30 to 70 °C (with no icing or condensation)
Operating: 35% to 85% / Storage: 35% to 95% (without condensation)
20 MΩ min. at 500 V DC between energized parts and case
1500 VAC, 50 / 60 Hz for 1 min between energized parts and case
10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z)
500 m/sqr (approx. 50 g) for each direction (X, Y, Z)
IP67 [3.]; NEMA 1, 2, 4
Infrared LED (880 nm)
Indicators
Light incident/power indicator for light source (red)
Fixed
Sensitivity adjustment
Connection method
Operation mode
Circuit protection
Weight (approx.)
Housing materials
2 m, 5 m pre-wired cable (PVC dia. 4 mm (14 / 0.15))
Light-ON or Dark-ON (fixed)
None
110 g (pre-wired 2 m cable)
Plastic (case: ABS; lens: PMMA)
Note: 1. For stable sensing distance in detail, please refer to “Engineering Data”
2. Typical sensing distance corresponds to 80% of the max. sensing distance.
3. The enclosure rating IP67 of OMRON internal standards correspond to stricter test requirements than the standard IEC 60529 (refer to
chapter “Precautions”)
Photoelectric Sensors E3F2
7
Engineering Data (Typical)
■ Operating Range (typical)
Through-beam Models (axial)
E3F2-7@4-@
Through-beam Models (axial)
E3F2-3Z@
Through-beam Models (axial)
E3F2-10@
500
400
300
200
100
300
200
typical sensing distance: 3.8 m
100
0
0
-100
-200
-300
-400
-500
–100
–200
Y
X
Y
X
–300
0
1
2
3
4
5
0
1
2
3
4
5
6
7
8
9 10 11 1213 1415 16 17
Distance X (m)
Distance X (m)
Retroreflective Models (axial)
E3F2-R2@4-@ (non polarizing)
and reflectors
Retroreflective Models (axial)
E3F2-R2Z@ (non polarizing)
and reflectors
Retroreflective Models (axial)
E3F2-R2R@4-@ (polarizing)
and reflectors
300
200
300
typical sensing distances:
typical sensing distances:
typical sensing distances:
E39-R1: 4.0 m
E39-R7: 4.5 m
E39-R8: 5.3 m
E39-R1: 3.4 m
E39-R7: 3.9 m
E39-R8: 5.2 m
E39-R1: 3.7 m
E39-R7: 4.2 m
E39-R8: 5.3 m
150
100
200
200
100
0
100
0
50
0
–50
–100
–200
–300
–100
–200
–300
–100
–150
–200
Reflector
Reflector
Reflector
Y
Y
Y
X
X
X
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
Distance X (m)
Distance X (m)
Distance X (m)
Retro-reflective Models (axial)
E3F2-R4@4@-@ (polarizing)
Retroreflective Models (radial)
E3F2-R2R@41-@ (polarizing)
and reflectors
250
100
Typical sensing distance
typical sensing distances:
E39-RS3
200 E39-R1S
E39-R40
E39-R1: 2.4 m
E39-R7: 2.7 m
E39-R8: 3.1 m
E39-R7
150
E39-R8
100
50
0
50
0
- 50
- 100
- 150
–50
Reflector
Reflector
Y
- 200
- 250
Y
X
X
–100
0
0.5
1
1.5
2
2.5
3
3.5
4
0
1
2
3
4
5
6
7
8
9
Distance X (m)
Distance X (m)
8
Photoelectric Sensors E3F2
Diffuse reflective Models (axial)
E3F2-DS10@4-@ (wide-beam type)
Diffuse reflective Models (axial)
E3F2-DS10Z-@ (wide-beam type)
Diffuse reflective Models (axial)
E3F2-DS30@4-@
40
15
30
Sensitivity adjusted to maximum
Sensitivity adjusted to 400 mm
30
10
20
20
5
10
0
10
0
white paper
(50 x 50 mm)
white paper
(50 x 50 mm)
white paper
(100 x 100 mm)
0
–10
–5
–10
–15
–10
–20
–30
–20 Sensing distance adjustable
between 0 and 550 mm
Object
40
Object
40
Object
–30
Y
Y
Y
X
X
X
–40
0
20
60
80
100
120
140
0
20
60
80
100
120
140
0
100
200
300
400
500
600
Distance X (mm)
Distance X (mm)
Distance X (mm)
Diffuse reflective Models (radial)
E3F2-DS30@41-@
Diffuse reflective Models (axial)
E3F2-D1@4-@
100
40
Sensitivity adjusted to 390 mm
80
White paper (90% reflectivity)
30
20
60
40
10
0
20
Sensing object:
100 x 100 mm
Sensing object:
300 x 300 mm
0
-20
–10
–20
–30
–40
-40
-60
Object
Y
Object
400
-80
Y
X
X
-100
0
100
200
300
400
500
0
200
600
800
1000 1200 1400 1600
Distance X (mm)
Distance X (mm)
■ Excess Gain Ratio vs. Distance (typical)
Through-beam Models (axial)
E3F2-7@4-@
Through-beam Models (axial)
E3F2-3Z@
Through-beam Models (axial)
E3F2-10@
100
100
100
10
10
10
1
1
0.1
0.1
1
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18
0
2
4
6
8
10
12
Distance X (m)
Distance [m]
Distance X (m)
Photoelectric Sensors E3F2
9
Retroreflective Models (axial)
E3F2-R2@4-@ (non polarizing)
and reflectors
Retroreflective Models (axial)
E3F2-R2Z@ (non polarizing)
and reflectors
Retroreflective Models (axial)
E3F2-R2R@4-@ (polarizing)
and reflectors
100
100
100
10
10
10
reflector E39-R1
reflector E39-R1
reflector E39-R1
reflector E39-R7
1
1
1
reflector E39-R7
reflector E39-R7
reflector E39-R8
reflector E39-R8
reflector E39-R8
0.1
0.1
0.1
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
8
Distance X (m)
Distance X (m)
Distance X (m)
Retroreflective Models (axial)
Retroreflective Models (radial)
E3F2-R2R@41-@ (polarizing)
and reflectors
E3F2-R4@4@-@
100
100
Reflectors:
E39-RS3
E39-R1S
E39-R40
E39-R7
E39-R8
10
10
reflector E39-R1
1
1
reflector E39-R7
reflector E39-R8
0.1
0.1
0
2
4
6
8
10
0
1
2
3
4
5
Distance X (m)
Distance X (m)
Diffuse reflective Models (axial)
Diffuse reflective Models (axial)
Diffuse reflective Models (axial)
E3F2-DS10@4-@ (wide-beam type)
E3F2-DS10Z-@ (wide-beam type)
E3F2-DS30@4-@
100
100
100
Sensitivity adjusted to maximum
Sensing object:
100 x 100 mm
Sensing object:
50 x 50 mm
Sensing object:
50 x 50 mm
10
10
10
White paper
(90% reflectivity)
White paper
(90% reflectivity)
White paper
(90% reflectivity)
Grey paper
(18% reflectivity)
1
1
1
Grey paper
(18% reflectivity)
Grey paper
(18% reflectivity)
0.1
0.1
0.1
0
50
100
150
200
0
200
400
600
800
1000
0
20
40
60
80
100
120
140
Distance X (mm)
Distance X (mm)
Distance X (mm)
10
Photoelectric Sensors E3F2
Diffuse reflective Models (radial)
E3F2-DS30@41-@
Diffuse reflective Models (axial)
E3F2-D1@4-@
100
10
1
100
Sensing object:
100 x 100 mm
Sensitivity adjusted to 390 mm
10
White paper
(90% reflectivity)
1
Grey paper
(18% reflectivity)
0.1
0,1
0
100
200
300
400
500
0
0.5
1
1.5
2
Distance X (mm)
Distance(m)
■ Light spot vs.
■ Incline (left and right) ■ Incline (up and down)
sensing distance
Background suppression Models
Background suppression Models
E3F2-LS@
Background suppression Models
E3F2-LS@
E3F2-LS@
20,00%
20,00%
6
4
2
10,00%
0,00%
10,00%
0,00%
-10,00%
-20,00%
-10,00%
-20,00%
0
0
50
100
150
-40 -30 -20 -10
0
10 20 30 40
-40 -30 -20 -10
0
10 20 30 40
Distance(mm)
Incline Angle (˚)
Incline Angle (˚)
■ Object material vs. sensing distance
Background suppression Models
E3F2-LS@
120,0
100,0
80,0
60,0
40,0
20,0
0,0
white
corrugated
paper
black
SUS
mirror
Photoelectric Sensors E3F2
11
Operation
■ Output Circuits
Structure of Sensor I/O Connector
Classification
Wire color
Brown
Connector
pin No.
Use
1
2
3
4
Brown
White
Blue
DC
Power supply
(+V)
1
Black
White
Blue
Modeselection
Lon/Don
2
3
4
Power supply
(0 V)
XS2F-D42#-D80-#
XS2F-G42#-G80-#
Black
Output
■ PNP Output
Model
Output transistor
Timing chart
Connection
method
Output circuit
Through-beam emitter
status
E3F2-@B4-@
(except for
E3F2-10B4-@ and
E3F2-LS10B4-@)
–
–
–
Brown
10 to 30 VDC
1
Power
indicator
(red)
Main
circuit
Blue
3
0 V
Connector Pin Arrangement
1
2
4
3
ON when light is
incident.
(Light-ON)
Connect the
Incident
Interrupted
Brown
10 to 30 VDC
2
pink (Pin
)
Light
indicator
Stability
indicator*
1
and brown
Output
indicator
(red)
ON
OFF
Z
D
Red
Green
1
(Pin ) cords or
open the pink
Black
Blue
Pink
4
3
2
Main
circuit
Z : V = 36 V
D Z
100 mA
max.
Output
transistor
ON
OFF
Load
0 V
2
cord (Pin ).
Load
(relay)
Operate
Release
Mode selection
Connector Pin Arrangement
1
*
Only on models
E3F2-R4B4-@ and
E3F2-D1B4-@
2
4
3
ON when light is
interrupted. (Dark-
ON)
Connect the
Incident
Interrupted
Brown
10 to 30 VDC
2
Light
indicator
Stability
indicator*
pink (Pin
and blue
3
)
1
Output
indicator
(red)
ON
OFF
Red
Green
(Pin ) cords.
Black
Blue
Pink
4
3
2
Main
circuit
Z : V = 36 V
D Z
100 mA
max.
Output
transistor
ON
OFF
Load
0 V
Load
(relay)
Operate
Release
Mode selection
Connector Pin Arrangement
1
*
Only on models
E3F2-R4B4-@ and
E3F2-D1B4-@
2
4
3
12
Photoelectric Sensors E3F2
Model
Output transistor
status
Timing chart
Connection
method
Output circuit
Through-beam emitter
E3F2-10B4-@
–
–
Test
ON
input
OFF
Light
emission
ON
OFF
Red
Indicator
ON
OFF
ON when light is
incident.
(Light-ON)
Connect the
Incident
Interrupted
2
pink (Pin
)
Brown
10 to 30 VDC
Output
indicator
1
and brown
Output
indicator
(orange)
ON
OFF
Z
D
Orange
1
(Pin ) cords or
open the pink
Black
Blue
Pink
4
3
2
Main
circuit
Z
D
: V = 36 V
Z
Output
transistor
ON
OFF
100 mA
max.
Load
0 V
2
cord (Pin ).
Load
(relay)
Operate
Release
Mode selection
Connector Pin Arrangement
1
2
4
3
ON when light is
interrupted. (Dark-
ON)
Connect the
Incident
Interrupted
2
Brown
pink (Pin
and blue
3
)
10 to 30 VDC
Output
indicator
1
Output
indicator
(orange)
ON
OFF
Orange
(Pin ) cords.
Black
Blue
Pink
4
3
2
Main
circuit
Z : V = 36 V
D Z
100 mA
max.
Output
transistor
ON
OFF
Load
0 V
Load
(relay)
Operate
Release
Mode selection
Connector Pin Arrangement
1
2
4
3
E3F2-LS10B4-@
ON when light is
incident.
(Light-ON)
Connect the
Incident
Interrupted
2
pink (Pin
)
Brown
10 to 30 VDC
Output
indicator
Stability
indicator*
1
and brown
Output
indicator
(orange)
ON
OFF
Z
D
Orange
Green
1
(Pin ) cords or
open the pink
Black
Blue
Pink
4
3
2
Main
circuit
Z : V = 36 V
D Z
Output
transistor
ON
OFF
100 mA
max.
Load
0 V
2
cord (Pin ).
Load
(relay)
Operate
Release
Mode selection
Connector Pin Arrangement
1
2
4
3
ON when light is
interrupted. (Dark-
ON)
Connect the
Incident
Interrupted
2
Brown
pink (Pin
and blue
3
)
10 to 30 VDC
Output
indicator
Stability
indicator*
1
Output
indicator
(orange)
ON
OFF
Orange
Green
(Pin ) cords.
Black
Blue
Pink
4
3
2
Main
circuit
Z : V = 36 V
D Z
100 mA
max.
Output
transistor
ON
OFF
Load
0 V
Load
(relay)
Operate
Release
Mode selection
Connector Pin Arrangement
1
2
4
3
Note: Terminal numbers for connector type.
Photoelectric Sensors E3F2
13
■ NPN Output
Model
Output transistor
Timing chart
Connection
method
Output circuit
Through-beam emitter
status
E3F2-@C4-@
(except for
E3F2-10C4-@ and
E3F2-LS10C4-@)
–
–
Brown
10 to 30 VDC
1
Power
indicator
(red)
Main
circuit
Blue
3
0 V
Connector Pin Arrangement
1
2
4
3
Brown
10 to 30 VDC
Load
ON when light is
incident.
(Light-ON)
Connect the
Output
indicator
Stability
indicator*
1
Incident
Interrupted
2
pink (Pin
)
Red
Green
100 mA
max.
and brown
Black
Blue
Pink
Output
indicator
(red)
ON
OFF
4
3
2
Main
circuit
1
(Pin ) cords or
open the pink
Output
transistor
ON
OFF
0 V
Z : V = 36 V
D Z
2
cord (Pin ).
Mode selection
Load
(relay)
Operate
Release
Connector Pin Arrangement
1
*
Only on models
E3F2-R4C4-@ and
E3F2-D1C4-@
2
4
3
Brown
10 to 30 VDC
Load
ON when light is
interrupted. (Dark-
ON)
Connect the
Output
indicator
Stability
indicator*
1
Incident
Interrupted
2
pink (Pin
and blue
3
)
Red
Green
100 mA
max.
Black
Blue
Pink
Output
indicator
(red)
ON
OFF
4
3
2
Main
circuit
(Pin ) cords.
Output
transistor
ON
OFF
0 V
Z : V = 36 V
D Z
Mode selection
Load
(relay)
Operate
Release
Connector Pin Arrangement
1
*
Only on models
E3F2-R4C4-@ and
E3F2-D1C4-@
2
4
3
E3F2-10C4-@
–
–
Through-beam emitter
Test
ON
input
OFF
Light
ON
emission
OFF
Red
Indicator
ON
OFF
Brown
ON when light is
incident.
(Light-ON)
Connect the
10 to 30 VDC
Load
Light
indicator
1
Incident
Interrupted
2
pink (Pin
)
Orange
100 mA
max.
and brown
Output
indicator
(red)
Black
Blue
Pink
ON
OFF
4
3
2
1
(Pin ) cords or
open the pink
Main
circuit
Output
transistor
ON
OFF
0 V
Z : V = 36 V
D Z
2
cord (Pin ).
Mode selection
Load
(relay)
Operate
Release
Connector Pin Arrangement
1
2
4
3
Brown
ON when light is
interrupted. (Dark-
ON)
Connect the
10 to 30 VDC
Load
Light
indicator
1
Incident
Interrupted
2
pink (Pin
and blue
3
)
Orange
100 mA
max.
Output
indicator
(orange)
Black
Blue
Pink
ON
OFF
4
3
2
(Pin ) cords.
Main
circuit
Output
transistor
ON
OFF
0 V
Z : V = 36 V
D Z
Mode selection
Load
(relay)
Operate
Release
Connector Pin Arrangement
1
2
4
3
14
Photoelectric Sensors E3F2
Model
Output transistor
status
Timing chart
Connection
method
Output circuit
Brown
E3F2-LS10C4-@
ON when light is
incident.
(Light-ON)
Connect the
10 to 30 VDC
Load
Output
indicator
Stability
indicator*
1
Incident
Interrupted
2
pink (Pin
)
Orange
Green
100 mA
max.
and brown
Output
indicator
(red)
Black
Blue
Pink
ON
OFF
4
3
2
1
(Pin ) cords or
open the pink
Main
circuit
Output
transistor
ON
OFF
0 V
2
Z : V = 36 V
D Z
cord (Pin ).
Mode selection
Load
(relay)
Operate
Release
Connector Pin Arrangement
1
2
4
3
ON when light is
interrupted. (Dark-
ON)
Connect the
Brown
10 to 30 VDC
Load
Output
indicator
Stability
indicator*
1
Incident
Interrupted
2
pink (Pin
and blue
3
)
Orange
Green
100 mA
max.
Output
indicator
(orange)
Black
Blue
Pink
ON
OFF
4
3
2
(Pin ) cords.
Main
circuit
Output
transistor
ON
OFF
0 V
Z : V = 36 V
D Z
Mode selection
Load
(relay)
Operate
Release
Connector Pin Arrangement
1
2
4
3
Note: Terminal numbers for connector type.
■ AC Output
Model
Output transistor
status
Timing chart
Connection
method
Output circuit
E3F2-3LZ
–
–
–
–
Through-beam emitter
Brown
Power
indicator
(red)
Main
circuit
24 to 240 VAC
Blue
E3F2-3Z1
E3F2-R2Z1
E3F2-DS10Z1-N
ON when light is
incident.
(Light-ON)
Incident
Interrupted
Output
indicator
(red)
ON
OFF
Output
transistor
ON
OFF
Brown
Light
indicator
200 mA
max.
Black
Load
(relay)
Operate
Release
Load
Red
Main
circuit
24 to 240 VAC
E3F2-3Z2
E3F2-R2Z2
E3F2-DS10Z2-N
ON when light is
interrupted. (Dark-
ON)
–
Blue
Incident
Interrupted
Output
indicator
(red)
ON
OFF
Output
ON
transistor
OFF
Load
(relay)
Operate
Release
Photoelectric Sensors E3F2
15
Dimensions Note: All units are in millimeters unless otherwise indicated
■ DC-Switching Models, plastic, axial type
Cable type
Connector type
Without potentiometer
E3F2-7@
E3F2-7@-P1
E3F2-10@
E3F2-10@ –P1
E3F2-R2@4-P1
E3F2-DS10@4-P1
E3F2-LS10@4-P1
E3F2-R4@4F-P1
E3F2-R2@4
E3F2-DS10@4-N
E3F2-LS10@4
E3F2-R4@4F
73
62
42.3
37
4.7 dia
4.8 dia
64.9
optical
area
optical
area
42.3
37
24
24
5
Light indicator
M18x1 6g
5
Light indicator
M18x1 6g
4
8
4
8
With potentiometer
E3F2-DS30@4
E3F2-D1@4
E3F2-DS30@4-P1
E3F2-D1@4-P1
73
62
49.3
42.3
37
64.9
49.3
42.3
37
4.7 dia
4.8 dia
optical
area
optical
area
24
24
5
Sensitivity adjustor
Light indicator
M18x1 6g
5
Sensitivity adjustor
Light indicator
M18x1 6g
4
8
4
8
16
Photoelectric Sensors E3F2
■ DC-Switching Models, plastic, radial type
Cable type
Connector type
Without potentiometer
E3F2-R2R@41
E3F2-R2R@41-P1
73
62
42.3
37
4.7 dia
4.8 dia
64.9
42.3
37
optical
area
optical
area
24
24
5
Light indicator
M18x1 6g
3.45
5
Light indicator
M18x1 6g
3.45
6.9
4
6.9
4
8
8
With potentiometer
E3F2-DS30@41
E3F2-DS30@41-P1
73
62
49.3
42.3
37
64.9
4.7 dia
4.8 dia
49.3
42.3
37
optical
area
optical
area
24
24
5
5
Sensitivity adjustor
Light indicator
M18x1 6g
3.45
3.45
6.9
4
6.9
4
Sensitivity adjustor
Light indicator
M18x1 6g
8
8
Photoelectric Sensors E3F2
17
■ DC-Switching Models, metal (brass and stainless steel), axial type
Cable type
Connector type
Without potentiometer
E3F2-7@-M
E3F2-7@-S
E3F2-7@-M1-M
E3F2-7@-M1-S
E3F2-10@-M
E3F2-10@-M1-M
E3F2-R2R@4-M1-M
E3F2-R2R@4-M
E3F2-DS10@4-M
E3F2-LS10@4-M
E3F2-R4@4F-M
E3F2-R2R@4-S
E3F2-DS10@4-S
E3F2-R2R@4-M1-S
E3F2-DS10@4-M1-M E3F2-DS10@4-M1-S
E3F2-LS10@4-M1-M
E3F2-R4@4F-M1-M
76
4.8 dia
4.8 dia
64.9
42.3
65.5
42.3
optical
area
optical
area
37
24
37
24
4
4
Light indicator
M18x1 6g
Light indicator
M18x1 6g
With potentiometer
E3F2-DS30@4-M
E3F2-R4@4-M
E3F2-D1@4-M
E3F2-DS30@4-S
E3F2-DS30@4-M1-M E3F2-DS30@4-M1-S
E3F2-R4@4-M1-M
E3F2-D1@4-M1-M
76
64.9
65.5
49.3
42.3
37
4.8 dia
4.8 dia
49.3
optical
area
42.3
37
optical
area
24
24
Sensitivity adjustor
Light indicator
4
4
Sensitivity adjustor
Light indicator
M18x1 6g
M18x1 6g
18
Photoelectric Sensors E3F2
■ DC-Switching Models, metal (brass and stainless steel), radial type
Cable type
Connector type
Without potentiometer
E3F2-R2R@41-M
E3F2-R2R@41-S
E3F2-R2R@41-M
E3F2-R2R@41-M1-S
76
65.5
42.3
37
4.8 dia
4.8 dia
64.9
42.3
optical
area
optical
area
37
24
24
4
6.9
4
3.45
Light indicator
Light indicator
M18x1 6g
M18x1.6g
With potentiometer
E3F2-DS30@41-M
E3F2-DS30@41-S
E3F2-DS30@41-M1-M E3F2-DS30@41-M1-S
76
64.9
49.3
42.3
37
65.5
4.8 dia
4.8 dia
49.3
optical
area
optical
area
42.3
37
24
24
6.9
4
Sensitivity adjustor
Light indicator
M18x1 6g
3.45
6.9
4
3.45
Sensitivity adjustor
Light indicator
M18x1 6g
■ AC-Switching Models, plastic, axial type
Cable type
Without potentiometer
E3F2-3Z@
E3F2-R2Z@
E3F2-DS10Z@-N
90
67.3
62
5 dia.
8
M18 x 1 6g
24
3.1
16.8 dia.
3.1
Light indicator
22
optical zone
Photoelectric Sensors E3F2
19
■ Accessories (Order Separately)
Reflectors
E39-R1
E39-R1S
E39-R3
29
3.4
6
4.5
3.4
40.3
34
R20
13.7
14˚
Two, 3.5 dia.
7.5
7
7
18.45
0.2
0.2
22.9
20
Adhesive tape side
11
22.5
19.3
59.9 52
16
Two, 3.2 dia.
R25.4
2-M3
25.4
34
34.8 38
8
41.8
Material, reflective
surface: acrylic
Rear surface: ABS
3.4
Material, reflective
surface: acrylic
2.7
1.6
1.2
10.1
Stainless steel
(SUS304)
Rear surface: ABS
2.6
10˚
1.2
E39-R8
E39-R7
9
100
92
7.4
84
4.5
92
100
for M3
E39-R40
8.7
84.5
77
77
84.5
for M3
Tape Reflectors
E39-RSA
E39-RS3
80
0.6
35
0.7
Adhesive
tape
Reflecting
surface
4 x R1
70
E39-RSB
40
0.7
Adhesive tape side
4-R1
Adhesive
tape
Reflecting
surface
4 x R1
20
Photoelectric Sensors E3F2
Installation
Lens Cap
E39-F31
Mounting Bracket
Y92E-B18
Glass plate
E3F2
Metal rim
Gasket
4 max.
20 dia.
Note: Hexagon bolt: M5 x 32
Material: plastic
Mounting Bracket
Y92E-G18
Approx. 35
23.5
20.5
30
M24x1.5
5
Sensor tightening nut
30
Two tightening nuts
30
30
Slit (for precision detection with E3F2-10@)
E39-ES18
16
1
4
21
Photoelectric Sensors E3F2
21
Precautions
The E3F2 Photoelectric Sensor is not a safety component for ensur-
ing the safety of people which is defined in EC directive (91/368/
EEC) and covered by separate European standards or by any other
regulations or standards.
When using the photoelectric sensor in the vicinity of an inverter
motor, ensure to connect the protective earth ground wire of the
motor to earth. Failure to ground the motor may result in malfunction
of the sensor.
When you use the photoelectric sensor at temperatures exceeding
45°C, the load current must be within the described values as shown
in the figure below.
■ Degree of protection
The E3F2 photoelectric sensors have a degree of protection rated
with IP67. In this case, the sensors have passed the OMRON heat
shock test before the IP67-test of IEC 60529 (submersion at 1m
water depth for 30 min). Afterwards the sensors have been tested
according to the OMRON waterproof test.
200
130
Heat shock: The Alternating, fast temperature changes between
-25°C and +55°C are executed for 5 cycles and 1 hour
for each temperature. Function and isolation are
checked.
Water proof: The sensors are submerged alternating in water of
+2°C and +55°C. 20 cycles with 1 hour for each tem-
perature are executed. Function, water tightness and
electrical isolation are checked.
0
45
55
Operating temperature (˚C)
Do not expose the photoelectric sensor to excessive shock during
installation, keeping within IP 67 standards.
■ Installation
Do not exceed a torque of
■ Wiring
If the input/output lines of the photoelectric sensor are placed in the
same conduit or duct as power lines or high-voltage lines, the photo-
electric sensor could be induced to malfunction, or even be damaged
by electrical noise. Separate the wiring, or use shielded lines as
input/output lines to the photoelectric sensor.
• 2.0 Nm (20 kgf cm) when tightening mounting nuts for plastic
models
• 20.0 Nm (200 kgf cm) when tightening mounting nuts for metal
models
Do not connect the black wire to the brown wire without a load. Direct
connection of these wires may damage the photoelectric sensor (AC
switching type).
Brown
Load
Sensor
24 to 240 VAC
Black
Blue
22
Photoelectric Sensors E3F2
Certain Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed 12. Warranties. (a) Exclusive Warranty. Seller's exclusive warranty is that the
part of all catalogs, manuals or other documents, whether electronic or in writ-
ing, relating to the sale of goods or services (collectively, the "Goods") by
Omron Electronics LLC and its subsidiary companies ("Seller"). Seller hereby
objects to any terms or conditions proposed in Buyer's purchase order or other
documents which are inconsistent with, or in addition to, these Terms. Please
contact your Omron representative to confirm any additional terms for sales
from your Omron company.
Goods will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Seller (or such other period expressed
in writing by Seller). Seller disclaims all other warranties, express or implied.
(b) Limitations. SELLER MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
ITY OR FITNESS FOR
A PARTICULAR PURPOSE OF THE GOODS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
GOODS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Seller further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Goods or other-
wise of any intellectual property right. (c) Buyer Remedy. Seller's sole obliga-
tion hereunder shall be to replace (in the form originally shipped with Buyer
responsible for labor charges for removal or replacement thereof) the non-
complying Good or, at Seller's election, to repay or credit Buyer an amount
equal to the purchase price of the Good; provided that in no event shall Seller
be responsible for warranty, repair, indemnity or any other claims or expenses
regarding the Goods unless Seller's analysis confirms that the Goods were
properly handled, stored, installed and maintained and not subject to contami-
nation, abuse, misuse or inappropriate modification. Return of any goods by
Buyer must be approved in writing by Seller before shipment. Seller shall not
be liable for the suitability or unsuitability or the results from the use of Goods
in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any
advice, recommendations or information given orally or in writing, are not to be
construed as an amendment or addition to the above warranty.
2. Prices. All prices stated are current, subject to change without notice by
Seller. Buyer agrees to pay the price in effect at time of shipment.
3. Discounts. Cash discounts, if any, will apply only on the net amount of
invoices sent to Buyer after deducting transportation charges, taxes and
duties, and will be allowed only if (i) the invoice is paid according to Seller's
payment terms and (ii) Buyer has no past due amounts owing to Seller.
4. Orders. Seller will accept no order less than $200 net billing.
5. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the impor-
tation or sale of the Goods.
6. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Seller or required to be collected directly or
indirectly by Seller for the manufacture, production, sale, delivery, importation,
consumption or use of the Goods sold hereunder (including customs duties
and sales, excise, use, turnover and license taxes) shall be charged to and
remitted by Buyer to Seller.
7. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Seller, Seller reserves the right to stop shipments or require satisfactory 13. Damage Limits; Etc. SELLER SHALL NOT BE LIABLE FOR SPECIAL, INDI-
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Seller may (without liability
and in addition to other remedies) cancel any unshipped portion of Goods sold
hereunder and stop any Goods in transit until Buyer pays all amounts, includ-
ing amounts payable hereunder, whether or not then due, which are owing to it
by Buyer. Buyer shall in any event remain liable for all unpaid accounts.
8. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Seller fully against all costs or expenses arising in
connection therewith.
RECT OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUC-
TION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE
GOODS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY,
NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of
Seller exceed the individual price of the Good on which liability is asserted.
14. Indemnities. Buyer shall indemnify and hold harmless Seller, its affiliates and
its employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, inves-
tigation, litigation or proceeding (whether or not Seller is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Goods. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Seller and defend or settle
any action brought against Seller to the extent that it is based on a claim that
any Good made to Buyer specifications infringed intellectual property rights of
another party.
15. Property; Confidentiality. The intellectual property embodied in the Goods is
the exclusive property of Seller and its affiliates and Buyer shall not attempt to
duplicate it in any way without the written permission of Seller. Notwithstand-
ing any charges to Buyer for engineering or tooling, all engineering and tooling
shall remain the exclusive property of Seller. All information and materials
supplied by Seller to Buyer relating to the Goods are confidential and propri-
etary, and Buyer shall limit distribution thereof to its trusted employees and
strictly prevent disclosure to any third party.
16. Miscellaneous. (a) Waiver. No failure or delay by Seller in exercising any right
and no course of dealing between Buyer and Seller shall operate as a waiver
of rights by Seller. (b) Assignment. Buyer may not assign its rights hereunder
without Seller's written consent. (c) Amendment. These Terms constitute the
entire agreement between Buyer and Seller relating to the Goods, and no pro-
vision may be changed or waived unless in writing signed by the parties.
(d) Severability. If any provision hereof is rendered ineffective or invalid, such
provision shall not invalidate any other provision. (e) Setoff. Buyer shall have
no right to set off any amounts against the amount owing in respect of this
invoice. (f) As used herein, "including" means "including without limitation".
9. Force Majeure. Seller shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
10. Shipping; Delivery. Unless otherwise expressly agreed in writing by Seller:
a. Shipments shall be by a carrier selected by Seller;
b. Such carrier shall act as the agent of Buyer and delivery to such carrier
shall constitute delivery to Buyer;
c. All sales and shipments of Goods shall be FOB shipping point (unless oth-
erwise stated in writing by Seller), at which point title to and all risk of loss of
the Goods shall pass from Seller to Buyer, provided that Seller shall retain a
security interest in the Goods until the full purchase price is paid by Buyer;
d. Delivery and shipping dates are estimates only.
e. Seller will package Goods as it deems proper for protection against normal
handling and extra charges apply to special conditions.
11. Claims. Any claim by Buyer against Seller for shortage or damage to the
Goods occurring before delivery to the carrier must be presented in writing to
Seller within 30 days of receipt of shipment and include the original transporta-
tion bill signed by the carrier noting that the carrier received the Goods from
Seller in the condition claimed.
Certain Precautions on Specifications and Use
1. Suitability of Use. Seller shall not be responsible for conformity with any stan- 2. Programmable Products. Seller shall not be responsible for the user's pro
dards, codes or regulations which apply to the combination of the Good in the
gramming of a programmable Good, or any consequence thereof.
Buyer's application or use of the Good. At Buyer's request, Seller will provide 3. Performance Data. Performance data given in this catalog is provided as a
applicable third party certification documents identifying ratings and limitations
of use which apply to the Good. This information by itself is not sufficient for a
complete determination of the suitability of the Good in combination with the
end product, machine, system, or other application or use. The following are
guide for the user in determining suitability and does not constitute a warranty
It may represent the result of Seller's test conditions, and the user must corre
late it to actual application requirements. Actual performance is subject to the
Seller's Warranty and Limitations of Liability.
some examples of applications for which particular attention must be given. 4. Change in Specifications. Product specifications and accessories may be
This is not intended to be an exhaustive list of all possible uses of this Good,
nor is it intended to imply that the uses listed may be suitable for this Good:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government
regulations.
changed at any time based on improvements and other reasons. It is our prac
tice to change part numbers when published ratings or features are changed
or when significant construction changes are made. However, some specifica
tions of the Good may be changed without any notice. When in doubt, specia
part numbers may be assigned to fix or establish key specifications for you
application. Please consult with your Seller's representative at any time to con
firm actual specifications of purchased Good.
5. Errors and Omissions. The information in this catalog has been carefully
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors, or omissions.
(iii) Systems, machines and equipment that could present a risk to life or
property. Please know and observe all prohibitions of use applicable to
this Good.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT
THE SELLER'S PRODUCT IS PROPERLY RATED AND INSTALLED FOR
THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Photoelectric Sensors E3F2
23
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at www.omron.com/oei – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONICS LLC
One Commerce Drive
Schaumburg, IL 60173
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.ca
847-843-7900
416-286-6465
For US technical support or other inquiries:
800-556-6766
Cat. No. E224-E3-04
04/05
Specifications subject to change without notice
Printed in USA
24
Photoelectric Sensors E3F2
相关型号:
©2020 ICPDF网 联系我们和版权申明