E3FR-R66H [OMRON]
Easy mounting photoelectric sensor in short M18 housing;型号: | E3FR-R66H |
厂家: | OMRON ELECTRONICS LLC |
描述: | Easy mounting photoelectric sensor in short M18 housing |
文件: | 总17页 (文件大小:1768K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Easy mounting photoelectric sensor in short M18 housing
E3FZ/E3FR
• Secure-click snap mounting for fast
installation
• High power LED for enhanced
sensing distance
• Short housing with less than
40 mm length
• Minimal optical axis deviation for easy
alignment
Features
Easy and fast installation
The SecureClick snap mounting mechanism provides easy
Installation time can be reduced by up to 10 times compared to
installation in 2 steps and enhanced protection against vibration. conventional sensors.
>>CLICK
2
1
Conventional
square sensors
Conventional
cylindrical
sensors
E3FZ with
SecureClick*
*SecureClick has been tested to withstand severe vibrations.
E3FZ/E3FR
1
Ordering Information
Snap mounting – E3FZ*2
Sensor type
Sensing distance
15 m
Connection method
Order code
NPN output
PNP output
*3
*3
*3
*3
*3
*3
*3
*3
*3
*3
Through-beam
E3FZ-T61H 2M
E3FZ-T66H
E3FZ-T81H 2M
E3FZ-T86H
–
–
–
–
–
–
–
–
–
–
–
–
2 m
–
–
–
–
–
–
–
–
–
–
–
*1
Retroreflective with M.S.R.
Diffuse reflective
0.1 to 4 m
E3FZ-R61H 2M
E3FZ-R66H
E3FZ-R81H 2M
E3FZ-R86H
2 m
–
–
1 m (adjustable)
E3FZ-D62 2M
E3FZ-D67
E3FZ-D82 2M
E3FZ-D87
2 m
–
–
Diffuse reflective
(background suppression)
100 mm (fixed)
E3FZ-LS61H 2M
E3FZ-LS66H
E3FZ-LS64H 2M
E3FZ-LS69H
E3FZ-LS81H 2M
E3FZ-LS86H
E3FZ-LS84H 2M
E3FZ-LS89H
2 m
–
–
2 m
–
200 mm (fixed)
Radial mounting – E3FR
Sensor type
Sensing distance
15 m
Connection method
Order code
NPN output
PNP output
Through-beam
E3FR-T61H 2M
E3FR-T66H
E3FR-T81H 2M
E3FR-T86H
*3
*3
*3
*3
*3
*3
*3
*3
*3
*3
–
–
–
–
–
–
–
–
–
–
–
–
2 m
–
–
–
–
–
–
–
–
–
–
–
*1
Retroreflective with M.S.R.
Diffuse reflective
0.1 to 4 m
E3FR-R61H 2M
E3FR-R66H
E3FR-R81H 2M
E3FR-R86H
E3FR-D82 2M
E3FR-D87
2 m
–
–
1 m (adjustable)
E3FR-D62 2M
E3FR-D67
2 m
–
–
Diffuse reflective
(background suppression)
100 mm (fixed)
E3FR-LS61H 2M E3FR-LS81H 2M
E3FR-LS66H E3FR-LS86H
E3FR-LS64H 2M E3FR-LS84H 2M
E3FR-LS69H E3FR-LS89H
2 m
–
–
2 m
–
200 mm (fixed)
*1.
Measured with reflector E39-R1S
The reflector is sold separately.
Mounting with Snap-Holder (provided with product) or M18 Nuts (provided with product) possible.
Pre-wired connectors are available on request (item description see "Model Number Legend" on page 4)
*2.
*3.
2
Standard Photoelectric Sensors
Accessories
Reflectors
Shape
Type
Material
Features
Size in mm
Applicable Sensor Order code
General purpose
reflectors
- ABS base
- Acrylic surface mounting
(diagonal holes)
Surface screw
59.9x40.3x7.5
- Retroreflective
photo electric
sensors –
E39-R1S
non polarizing
- Retroreflective
photo electric
sensors –
Snap mounting
dia 30 mm
(reflector)
E39-R49
polarizing (MSR)
dia 6.5 mm
(snap mount)
Mounting brackets
Shape
Type
Material
Features
Applicable Sensor Order code
General purpose
mounting
stainless steel
Horizontal angle adjustment
E3FZ (dia 20mm
snap holder)
E39-EL8
Telescope
mounting
3D rotation (fits to 12 mm mounting
rod)
E39-EL9
Sensor I/O connectors
Straight
2 m
4-wire
PVC
PUR
PVC
PUR
PVC
PUR
PVC
PUR
XS2F-D421-D80-A
Y92E-M12PUR4S2M-L
XS2F-D421-G80-A
5 m
2 m
5 m
Y92E-M12PUR4S5M-L
XS2F-D422-D80-A
L-shaped
Y92E-M12PUR4A2M-L
XS2F-D422-G80-A
Y92E-M12PUR4A5M-L
Note: For the complete list of sensor I/O connectors refer to E26E Accessories datasheet.
E3FZ/E3FR
3
Model Number Legend
E3F@-@@@@-@-@@
1
2 3 4 5 6 7 8 9
e.g., E3FZ-T81H; short housing/ through-beam/PNP output/2 m cable/without an adjustor/L-on/D-on by wire/
E3FZ-T86H-D; short housing/through-beam/PNP output/M12 connector/without an adjustor/L-on/D-on by wire/receiver
E3FR-LS86; radial housing/background-suppression/PNP output/M12 connector/sensing distance of 100 mm/without an adjustor/
L-on/D-on by wire/
1. Cylindrical family name: E3F
2. Series name
6. Adjuster
Blank: with volume adjuster/L-on/D-on by wire
H: without volume adjuster/L-on/D-on by wire
2: standard housing (seperate naming rule)
Z: short housing
7. Emitter/ Receiver
R: radial housing
L: emitter
3. Sensing method
D: receiver
T: through-beam
8. Kind of connection
R: retroreflective
D: diffuse reflective
LS: background suppression
Blank: standard 2 m cable or M12 connector
M1J: pre-wired with 30 cm cable and
M12 plug connector (4 pin)
4. Output
M3J: pre-wired with 30 cm cable and
M8 plug connector (4 pin)
M5J: pre-wired with 30 cm cable and
M8 plug connector (3 pin)
M1TJ: pre-wired with 30cm cable and Twist&Click
M12 plug connector (4 pin)
6: NPN output
8: PNP output
5. Connection
Through-beam, retroreflective types
1: 2 m cable
9. Cable length
6: M12 connector
Blank: M12 connector
Number: cable length
Diffuse reflective types
2: 2 m cable
7: M12 connector
Background suppression types
1: 2 m cable/sensing distance of 100 mm
4: 2 m cable/sensing distance of 200 mm
6: M12 connector/sensing distance of 100 mm
9: M12 connector/sensing distance of 200 mm
4
Standard Photoelectric Sensors
Mounting and dismounting
Mounting
Step 1
2.5 to 2.9 mm
Insert the snap holder into the
mounting hole from the front
Verify the correct position
(a clicking sound can be heard)
Step 2
Insert the sensor into the snap
Verify the correct position
holder from the back
(a clicking sound can be heard)
Dismounting
Step 1
Apply soft pressure to the sensor
lens in the indicated areas (e.g. with
two thumbs)
Remove the sensor
Step 2
Press down both snap-fits and push
Remove the snap holder
the snap holder forward.
E3FZ/E3FR
5
Specifications
Item
Through-beam
Retroreflective
E3FZ-R / E3FR-R
4 m [100 mm]
Diffuse reflective
E3FZ-T / E3FR-T
E3FZ-D / E3FR-D
Sensing distance
Spot diameter
15 m
1 m (white paper 300x300 mm)
–
Standard sensing object
Differential travel
Opaque: 12 mm dia .min
Opaque: 75 mm dia. min
–
–
20% max. of sensing distance
max.
Black/white error
–
Directional angle
Emitter and Reciever: 3° to 15° Sensor: 3° to 10°, Reflector: 30° –
Light source (wave length)
Power supply voltage
Current consumption
Infrared LED (870 nm)
Red LED (660 nm)
Infrared LED (860 nm)
10 to 30 VDC, including 10% ripple(p-p)
45mA max.
25 mA max.
(Emitter: 25mA max.,
Receiver; 20 mA max. )
Control output
Load power supply voltage; 30 VDC max., Load current; 100 mA max.(Residual voltage; 2 V max.),
Light-on/Dark-on selectable by wire,
E3F@-6@: NPN open-collector output
E3F@-8@: PNP open-collector output
Protective circuits
Power supply reverse polarity
protection, output short-circuit
Power supply reverse polarity protection,
output short-circuit protection, mutual interference prevention and
protection, and reversed output reversed output polarity protection
polarity protection
Response time
Operate and reset; 1 ms max.
Sensitivity adjustment
–
One-turn adjuster
Ambient illumination
Incandescent lamp; 3000 lx max., Sunlight 10000 lx max.
(receiver side)
Ambient temperature
Ambient humidity
Operating; -25 to +55°C, Storage; -40 to +70°C (with no icing or condensation)
Operating; 35 to 85% RH, Storage; 35 to 95% RH (with no condensation)
20MΩ min. at 500 VDC
Insulation resistance
Dielectric resistance
Vibration resistance
Shock resistance
1000 VAC at 50/60 Hz for 1 min
Destruction; 10 to 55 Hz, 1.5 mm double amplitude for 2 hours, each in X, Y and Z directions
Destruction; 500 m/s2, 3 times, each in X, Y and Z directions
IEC 60529 IP67, IP69K after DIN 40050-9
*1
Degree of protection
Connection method
Indicator
Pre-wired cable (standard length 2 m), Standard M12 connector
Operation indicator: yellow, stability indicator: green
(Emitter has only power supply indicator; green)
Weight
(packed state)
Pre-wired
approx. 120 g
approx. 40 g
approx. 60 g
approx. 20 g
Standard
connector
Material
Case
ABS
Cover lens
PMMA
Plate window
Accessories
Instruction sheet, 2x M18 nuts, snap mounting tool (E3FZ only).
*1.
The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water
at 80°C is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from
high pressure water in appearance and functionality.
6
Standard Photoelectric Sensors
Specification
Item
Background suppression (BGS)
E3FZ-LS@1H / E3FR-LS@1H
E3FZ-LS@6H / E3FR-LS@6H
E3FZ-LS@4H / E3FR-LS@4H
E3FZ-LS@9H / E3FR-LS@9H
Sensing distance
10 to 100 mm (White paper 100x100 mm)
4 mm dia. at sensing distance of 100 mm
–
10 to 200 mm (White paper 100x100 mm)
18 mm dia. at sensing distance of 200 mm
Spot diameter
Standard sensing object
Differential travel
3% of sensing distance max.
5% of sensing distance max.
–
20% of sensing distance max.
20% of sensing distance max.
Black/white error
Directional angle
Light source (wave length)
Power supply voltage
Current consumption
Control output
Red LED (650 nm)
Red LED (660 nm)
10 to 30 VDC, including 10% ripple(p-p)
25 mA max.
Load power supply voltage; 30 VDC max., Load current; 100 mA max. (Residual voltage; 2 V max.),
Light-on/Dark-on selectable by wire,
E3F@-LS6: NPN open-collector output
E3F@-LS8: PNP open-collector output
Protective circuits
Power supply reverse polarity protection, output short-circuit protection,
mutual interference prevention and reversed output polarity protection
Response time
Operate and reset; 1 ms max.
Sensitivity adjustment
–
Ambient illumination
Incandescent lamp; 3000 lx max., Sunlight 10000 lx max.
(receiver side)
Ambient temperature
Ambient humidity
Operating; -25 to +55°C, Storage; -40 to +70°C (with no icing or condensation)
Operating; 35 to 85%RH, Storage; 35 to 95%RH (with no condensation)
20MΩ min. at 500 VDC
Insulation resistance
Dielectric resistance
Vibration resistance
Shock resistance
1000 VAC at 50/60 Hz for 1 min
Destruction; 10 to 55 Hz, 1.5 mm double amplitude for 2 hours, each in X, Y and Z directions
Destruction; 500m/s2, 3 times, each in X, Y and Z directions
IEC 60529 IP67, IP69K after DIN 40050-9
*1
Degree of protection
Connection method
Indicator
Pre-wired cable (standard length 2m), Standard M12 connector
Operation indicator: yellow, stability indicator: green
approx.60g
Weight
Pre-wired
(packed state)
Standard
connector
approx.20g
Material
Case
ABS
Cover-lens
PMMA
Plate-window
Accessories
Instruction sheet, 2x M18 nuts, snap mounting tool (E3FZ only).
*1.
The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water
at 80ºC is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from
high pressure water in appearance and functionality.
E3FZ/E3FR
7
Engineering Data (typical)
Parallel Operating Range
Through-beam Models
E3F@-T@1H(T@6H)
Retroreflective Models
E3F@-R@1H(R@6H)
150
1500
E39-R1S
100
1000
E39-R1
50
0
500
Y
Y
0
X
X
-50
-500
-100
-150
-1000
-1500
0
1
2
3
4
5
6
0
5
10
15
20
25
30
35
40
Distance X (m)
Distance X (m)
Operating Range
Diffuse reflective Models
BGS Models
E3F@-D@2(D@7)
E3F@-LS@1H(LS@6H), left to right
E3F@-LS@4H(LS@9H), left to right
140
4
8
Sensing object: 100 x 100 white paper
Sensing object: 300 x 300 white paper
Sensing object: 100 x 100 white paper
120
100
80
3
2
1
0
6
4
Y
Y
X
60
40
2
X
20
Y
0
0
-20
-40
-60
-80
-100
X
-1
-2
-4
-6
-8
-2
-3
-120
-140
-4
0
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6 1.8
20
40
60
80
100
0
50
100
150
200
250
Distance X (mm)
Distance X (m)
Distance X (mm)
Excess Gain vs. Distance
Through-beam Models
Retroreflective Models
Diffuse reflective Models
E3F@-D@2(D@7)
100
E3F@-T@1H(T@6H)
100
E3F@-R@1H(R@6H)
100
Sensing object: 300 x 300 white paper
50
50
50
30
30
30
10
10
10
5
5
5
E39-R1S
3
3
3
E39-R1
Oper-
Oper-
ating
level
Oper-
ating
level
ating
1
1
1
level
0.5
0.3
0.5
0.5
0.3
0.3
0.1
0.1
0.1
0
5
10 15 20 25 30 35 40 45 50
0
0.5
1
1.5
2
2.5
0
1
2
3
4
5
6
Distance (m)
Distance (m)
Distance (m)
8
Standard Photoelectric Sensors
Sensing Object Size vs. Distance
Diffuse reflective Models
Spot Diameter vs. Distance
BGS Models
E3F@-D@2(D@7)
1.8
E3F@-LS@1H(LS@6H)
E3F@-LS@4H(LS@9H)
20
12
18
1.6
1.4
1.2
1.0
0.8
0.6
0.4
10
8
16
14
12
10
8
6
4
6
4
d
2
0
Sensing object: White paper
0.2
2
d
0.0
0
0
20
40
60
80
100
0
100
200
300
400
500 600
0
50
100
150
200
250
Distance (mm)
Distance (mm)
Length d of sensing object (mm)
Sensing Distance vs. Sensing Object Material
BGS Models
Inclination Characteristics (Vertical)
BGS Models
E3F@-LS@1H(LS@6H)
120
E3F@-LS@4H(LS@9H)
250
E3F@-LS@1H(LS@6H)
10
Upwards and
Downwards
8
Inclination
angle
100
80
60
200
150
6
+θ
−θ
Sensing
object
4
2
Center
line
0
100
50
-2
-4
-6
40
20
-8
0
0
-10
Black
rubber
Black
rubber
-80 -60 -40 -20
0
20
40
60 80
Black
paper
board
SUS Mirror
surface
Black
paper
SUS Mirror
surface
White Veneer Card-
paper
White Veneer Card-
paper board
Inclination angle (°)
Material
Material
Inclination Characteristics (Horizontal)
BGS Models
E3F@-LS@1H(LS@6H)
E3F@-LS@4H(LS@9H)
E3F@-LS@4H(LS@9H)
50
50
50
(Left and Right)
Upwards and
Downwards
(Left and Right)
Inclination
angle
Inclination
angle
40
40
40
Inclination
angle
+θ
+θ
−θ
+θ
30
30
30
Sensing
object
−θ
Sensing
object
+θ
Sensing
object
Center
line
Center
line
Center
20
10
0
20
20
line
10
0
10
0
10
20
30
10
20
30
10
20
30
40
50
40
50
40
50
-80 -60 -40 -20
0
20
40
60 80
-80 -60 -40 -20
0
20
40
60 80
(°)
-80 -60 -40 -20
0
20
40
60 80
(°)
Inclination angle
Inclination angle
Inclination angle
(°)
E3FZ/E3FR
9
Output Circuit Diagram
PNP Output
Model
Operation Timing charts
Mode
Output circuit
mode
selector
switch
E3F@-T8
E3F@-R8
E3F@-D8
Light ON
Connect the
pink wire
(Pin(2)) to
the brown
Light Incident
Light Interrupted
Operation indicator
ON
OFF
ON
(yellow)
Output transistor
(Pin(1)) or
open the pink
wire (Pin(2).
OFF
Through-beam Receivers, retroreflective models,
diffuse reflective models
Operate
Reset
Load
(e.g., relay)
10 to 30 VDC
Brown
(Between brown
and black wires)
Operation
indicator
(Yellow)
Stability
indicator
(Green)
1
ZD
Dark ON
Connect the
pink wire
(Pin(2)) to
the blue
Light Incident
Black
Photo-
4
Light Interrupted
electric
Sensor
Main
(Control
output)
100 mA
max.
Load
(Relay)
Operation indicator
(yellow)
ON
OFF
ON
Circuit
3
0 V
Blue
Output transistor
(Pin(3)).
OFF
Operate
Reset
Load
(e.g., relay)
(Between brown
and black wires)
Through-beam Emitter
Brown
Power
1
indicator
(green)
Photo-
electric
Sensor
Main
10 to 30 VDC
Circuit
Blue
3
NEAR
FAR
E3F@-LS8
Light ON
Dark ON
Connect the
pink wire
(Pin(2)) to
the brown
(Pin(1)) or
open the pink
wire (Pin(2).
Operation indicator
(yellow)
ON
OFF
ON
Output transistor
Load
10 to 30 VDC
Brown
Black
OFF
Stability
indicator
(Green)
Operation
indicator
(Yellow)
1
4
Operate
Reset
(e.g., relay)
Light-ON
ZD
100 mA max.
(Between brown
and black wires)
(Control output)
Photo-
electric
Sensor
Main
Load
(Relay)
NEAR
FAR
Connect the
pink wire
(Pin(2)) to
the blue
Blue
Pink
Circuit
3
Operation indicator
(yellow)
ON
OFF
0 V
Dark-ON
2
ON
OFF
Output transistor
Operate
Reset
Load
(e.g., relay)
(Pin(3)).
(Between brown
and black wires)
10
Standard Photoelectric Sensors
NPN Output
Model
Operation Timing charts
mode
Mode
selector
switch
Output circuit
E3F@-T6
E3F@-R6
E3F@-D6
Light ON
Connect the
pink wire (2)
to the blue
wire (3) or
Light Incident
Light Interrupted
Operation indicator
ON
OFF
ON
(yellow)
Output transistor
leave open.
OFF
Through-beam receivers, retroreflective models,
diffuse reflective models
Operate
Reset
Load
(e.g., relay)
Brown
10 to 30 VDC
(Between brown
and black wires)
Operation
indicator
(Yellow)
Stability
indicator
(Green)
1
Load
(Relay)
(Control
output)
Dark ON
Connect the
pink wire (2)
to the brown
wire (1).
100 mA
max.
Light Incident
Photo-
Light Interrupted
4
electric
Sensor
Main
Black
Blue
Operation indicator
(yellow)
ON
OFF
ON
ZD
Circuit
3
0 V
Output transistor
OFF
Operate
Reset
Load
(e.g., relay)
(Between brown
and black wires)
Through-beam Emitter
Brown
Power
1
indicator
(green)
Photo-
electric
Sensor
Main
10 to 30 VDC
Circuit
Blue
3
NEAR
FAR
E3F@-LS6
Light ON
Dark ON
Connect the
pink wire (2)
to the blue
wire (3) or
Operation indicator
(yellow)
ON
OFF
ON
Output transistor
OFF
10 to 30 VDC
Light-ON
Brown
Black
Stability
indicator
(Green)
Operation
indicator
(Yellow)
1
4
Load
(e.g., relay)
Operate
Reset
leave open.
Load
(Relay)
(Between brown
and black wires)
Photo-
100 mA max.
(Control output)
electric
Sensor
Main
Z
D
NEAR
FAR
Connect the
pink wire (2)
to the brown
wire (1).
Blue
Pink
Circuit
3
Operation indicator
(yellow)
0 V
ON
OFF
Dark-ON
2
ON
OFF
Output transistor
Operate
Reset
Load
(e.g., relay)
(Between brown
and black wires)
Connector Pin Arrangement
M12 Pre-wired Connector (-M1J)
M12 Connector Pin Arrangement
Connectors (Sensor I/O connectors)
M12 4-wire Connectors
Pin No.
Wire color
1
2
3
4
2
Brown
White
Blue
1
1
3
2
4
Black
4
3
XS2F-D421-D80-A
XS2F-D421-G80-A
XS2F-D422-D80-A
XS2F-D422-G80-A
Classification
DC
Wire color Connector pin No.
Application
Power supply (+V)
Operation selection
Power supply (0 V)
Output
Brown
White
Blue
A
B
C
D
Black
E3FZ/E3FR
11
Dimensions
Note: All units are in millimeters unless otherwise stated.
E3FZ-Series
Pre-wired models
Connector models
E3FZ-T@
Emitter
Power indicator (green)
Power indicator (green)
M18x1 6g
M18x1 6g
Optical Axis
15
16.25
M12x1 6g
9.30
16.25
5.20
30.25
30.35
E3FZ-T@
Receiver
Stability indicator (green)
Operation indicator (yellow)
Stability indicator (green)
Operation indicator (yellow)
M18x1 6g
M18x1 6g
Optical Axis
15
16.25
M12x1 6g
9.30
16.25
5.20
30.25
30.35
E3FZ-R@
E3FZ-LS@
Stability indicator (green)
Operation indicator (yellow)
Stability indicator (green)
Operation indicator (yellow)
M18x1 6g
M18x1 6g
Emitter
Optical Axis
Receiver
15
16.25
M12x1 6g
9.30
16.25
5.20
30.25
30.35
E3FZ-D@
Stability indicator (green)
Stability indicator (green)
M18x1 6g
M18x1 6g
Emitter
Operation indicator (yellow)
Sensitivity adjuster
Operation indicator (yellow)
Sensitivity adjuster
Optical Axis
Receiver
15
16.25
22.55
30.25
M12x1 6g
9.30
16.25
5.20
30.35
12
Standard Photoelectric Sensors
E3FR Series
Pre-wired models
Connector models
E3FR-T@1H 2M
Power indicator (green)
30.35
25.75
18.25
10.75
25.75
18.25
10.75
16.25
Optical axis
Optical axis
Emitter
Stability indicator (green)
Operation indicator (yellow)
M18x1 6g
M18x1 6g
30.35
M12x1 6g
16.25
4 dia
Receiver
E3FR-R@1H 2M
E3FR-LS@1H 2M
25.75
18.25
10.75
25.75
18.25
10.75
Receiver
Optical axis
3.50
Receiver
Optical axis
3.50
Stability indicator (green)
Operation indicator (yellow)
30.35
Emitter
Emitter
16.25
M18x1 6g
M18x1 6g
M12x1 6g
4 dia
E3FR-D@2 2M
25.75
18.25
10.75
25.75
18.25
10.75
Receiver
Optical axis
3.50
Receiver
Optical axis
3.50
Stability indicator (green)
Operation indicator (yellow)
30.35
Emitter
22.55
16.25
Emitter
M18x1 6g
M18x1 6g
M12x1 6g
Sensitivity adjuster
4 dia
E3FZ/E3FR
13
Accessories
E39-R1S
40.3
34
Two, 3.5 dia.
7.5
7
59.9 52
Material:
ABS base,
acrylic surface
8
2.7
1.6
E38-R49
34.5
7.4
32.8
12.6
6.5
Material:
ABS base,
acrylic surface
~ 2-3
E39-EL8
2.5
4.3
6
30
42
Material:
stainless steel
E39-EL9
(can be attached
to dia 12 mm
mounting rod)
Material:
stainless steel
Snap mount tool
1.5
15.5
Material:
ABS
14
Standard Photoelectric Sensors
Safety precautions
Precautions for Correct Use
! Warning
Do not use the Sensor in any atmosphere or environment that
exceeds the ratings.
Do not install the Sensor in the following locations.
(1)Locations subject to direct sunlight
This product is not designed or rated for directly or
indirectly ensuring safety of persons. Do not use it for
such a purpose.
(2)Locations subject to condensation due to high humidity
(3)Locations subject to corrosive gas
! Caution
(4)Locations where the Sensor may receive direct vibration or
shock
Connecting and Mounting
Do not use the product with voltage in excess of the
rated voltage. Excess voltage may result in malfunc-
tion or fire.
(1)The maximum power supply voltage is 30 VDC. Before turning
the power ON, make sure that the power supply voltage does
not exceed the maximum voltage.
Never use the product with an AC power supply.
Otherwise, explostion may result.
(2)Laying Sensor wiring in the same conduit or duct as high-volt-
age wires or power lines may result in malfunction or damage
due to induction. As a general rule, wire the Sensor in a sepa-
rate conduit or use shielded cable.
When cleaning the product, do not apply a high-pres-
sure spray of water to one part of the product. Other-
wise, parts may become damaged and the degree of
protection may be degraded.
2
(3)Use an extension cable with a minimum thickness of 0.3 mm
and less than 100 m long.
(4)Do not pull on the cable with excessive force.
(5)Pounding the Photoelectric Sensor with a hammer or other
tool during mounting will impair water resistance.
(6)Mount the Sensor either using the bracket (sold separately) or
on a flat surface.
High-temperature environments may result in burn
injury.
(7)Be sure to turn OFF the power supply before inserting or re-
moving the connector.
Cleaning
Precautions for Safe Use
Never use thinner or other solvents. Otherwise, the Sensor sur-
face may be dissolved.
Power Supply
If a commercial switching regulator is used, ground the FG (frame
ground) terminal.
Power Supply Reset Time
The Sensor will be able to detect objects 100 ms after the power
supply is tuned ON. Start using the Sensor 100 ms or more after
turning ON the power supply. If the load and the Sensor are con-
nected to separate power supplies, be sure to turn ON the Sensor
first.
The following precautions must be observed to ensure safe
operation of the Sensor.
Operating Environment
Do not use the Sensor in an environment where explosive or
flammable gas is present.
Connecting Connectors
Be sure to hold the connector cover when inserting or removing
the connector. Be sure to tighten the connector lock by hand;
do not use pliers or other tools. If the tightening is insufficient, the
degree of protection will not be maintained and the Sensor may
become loose due to vibration. The appropriate tightening torque
is 0.39 to 0.49 N·m for M12 connectors.
Turning OFF the Power Supply
Output pulses may be generated even when the power supply is
OFF. Therefore, it is recommended to first turn OFF the power
supply for the load or the load line.
Load
Do not use a load that exceeds the rated load.
Rotation Torque for Sensitivity Adjustment
Adjust with a torque of 0.05 N·m or less.
Load Short-circuit Protection
This Sensor is equipped with load short-circuit protection, but be
sure to not short circuit the load. Be sure to not use an output cur-
rent flow that exceeds the rated current. If a load short circuit oc-
curs, the output will turn OFF, so check the wiring before turning
ON the power supply again. The short-circuit protection circuit will
be reset. The load short-circuit protection will operate when the
current flow reaches 1.8 times the rated load current. When using
a capacitive load, use an inrush current of 1.8 times the rated load
current or higher.
Environements with Cleaners and Disinfectants
(e.g., Food Processing Lines)
Do not use the Sensor in environments subject to cleaners and
disifectants. They may reduce the degree of protection.
Modifications
Do not attempt to disassemble, repair, or modify the Sensor.
Outdoor Use
Do not use the Sensor in locations subject to direct sunlight.
Cleaning
Do not use thinner, alcohol, or other organic solvents. Otherwise,
the optical properties and degree of protection may be degraded.
Surface Temperature
Water Resistance
Do not use the Sensor in water, rainfall, or outdoors.
Burn injury may occur. The Sensor surface temperature rises de-
pending on application conditions, such as the surrounding tem-
perature and the power supply voltage. Use caution when
operating or washing the Sensor.
E3FZ/E3FR
15
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change with-
out notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or oth-
erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-
gation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsi-
ble for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were prop-
erly handled, stored, installed and maintained and not subject to contamina-
tion, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Compa-
nies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environ-
ments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for pub-
lished information.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the impor-
tation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon, 14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importa-
tion, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory 15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liabil-
ity and in addition to other remedies) cancel any unshipped portion of Prod-
ucts sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, inves-
tigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or set-
tle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
sive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a.Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall 17. Export Controls. Buyer shall comply with all applicable laws, regulations and
constitute delivery to Buyer;
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
c. All sales and shipments of Products shall be FOB shipping point (unless oth-
erwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security inter- 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
est in the Products until the full purchase price is paid;
d.Delivery and shipping dates are estimates only; and
e.Omron will package Products as it deems proper for protection against nor-
mal handling and extra charges apply to special conditions.
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law princi-
ples). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability. If any provi-
sion hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “including” means “including without limitation”; and “Omron Compa-
nies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original trans-
portation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Omron will provide applicable third party certification documents identifying 2. Programmable Products. Omron Companies shall not be responsible for the
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Prod- 3. Performance Data. Data presented in Omron Company websites, catalogs
user’s programming of a programmable Product, or any consequence thereof.
uct in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
and other materials is provided as a guide for the user in determining suitabil-
ity and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application require-
ments. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
(i) Outdoor use, uses involving potential chemical contamination or electrical 4. Change in Specifications. Product specifications and accessories may be
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equip-
ment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or prop-
erty. Please know and observe all prohibitions of use applicable to this Prod-
uct.
changed at any time based on improvements and other reasons. It is our prac-
tice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifica-
tions of the Product may be changed without any notice. When in doubt, spe-
cial part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
5. Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
OMRON INDUSTRIAL AUTOMATION • THE AMERICAS HEADQUARTERS • Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.55.59.01.43.00 • 001.800.556.6766 • mela@omron.com
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 001.800.556.6766 • mela@omron.com
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON EUROꢀE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands.
• Tel: +31 (0) 23 568 13 00 • Fax: +31 (0) 23 568 13 88 • www.industrial.omron.eu
Authorized Distributor:
Automation Systems
• Programmable logic controllers (PLC) • Human machine interfaces (HMI) • Remote I/O
• Industrial PC’s • Software
Motion & Drives
• Motion controllers • Servo systems • AC drives
Control Components
• Temperature controllers • Power supplies • Timers • Counters • Programmable relays
• Digital panel indicators • Electromechanical relays • Monitoring products • Solid-state relays
• Limit switches • Pushbutton switches • Low voltage switch gear
Sensing & Safety
• Photoelectric sensors • Inductive sensors • Capacitive & pressure sensors
• Cable connectors • Displacement & width-measuring sensors • Vision systems
• Safety networks • Safety sensors • Safety units/relay units • Safety door/guard lock switches
Cat. No. E55E-EN-01
03/11
Note: Specifications are subject to change.
© 2011 Omron Electronics LLC
Printed in U.S.A.
Printed on recycled paper.
相关型号: