E3S-5E4S-452M [OMRON]
Through Beam Photoelectric Sensor, 200mm Max, 80mA, Rectangular,;型号: | E3S-5E4S-452M |
厂家: | OMRON ELECTRONICS LLC |
描述: | Through Beam Photoelectric Sensor, 200mm Max, 80mA, Rectangular, 传感器 换能器 |
文件: | 总5页 (文件大小:187K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Paper Bag Contents Sensor
E3S-5E4S-45
CSM_E3S-5E4S-45_DS_E_3_1
Liquid Detection in Paper Bags!
• 10 Times Higher Incident Level Than Our Company Rating
• IP67 Waterproof
• Shock Resistant Die-cast Case
Be sure to read Safety Precautions on
page 3.
Ordering Information
Infrared light
Model
Sensors
Sensing method
Appearance
Sensing distance
Through-beam
E3S-5E4S-45 2M
200 mm
Accessories (Order Separately)
Mounting Brackets
Appearance
Model
Quantity
Remarks
E39-L6
1
Provided with the Sensor.
Note: Two of the accessories must be prepared for the beam-through type. One of them is for an emitter and the other is for a receiver.
1
E3S-5E4S-45
Ratings and Specifications
Sensing method
Through-beam
E3S-5E4S-45
Item
Model
Sensing distance
Standard object
Directional angle
Through-beam for paper bags: 200 mm (For standard through-beam use: 10 m)
Liquid or solid object, Opaque of 11-mm dia. min.
Emitter/Receiver: 10 to 30° each
Light source (wavelength)
Power supply voltage
Current consumption
Red LED (890 nm)
12 to 24 VDC±10%, ripple (p-p): 10% max.
45 mA max. (Emitter: 25 mA max., Receiver: 20 mA max.)
Load power supply voltage: 24 VDC max., Load current: 80 mA max. (residual voltage: 1 V max.)
NPN voltage output configuration Light-ON/Dark-ON mode selector
Control output
Load power supply voltage: 24 VDC max., Load current: 50 mA max. (residual voltage: 1 V max.)
Voltage output type
Self-diagnosis output
External-diagnosis input
Emission OFF: Short-circuit to 0 V or 1.5 V max. (Outflow current 1 mA max.), Emission ON: Disconnected
(Leakage current 0.1 mA max.)
Protective circuits
Response time
Power supply reverse polarity protection, Output short-circuit protection
Operate or reset: 10 ms max.
Sensitivity adjustment
One-turn adjuster
Ambient illumination
(Receiver side)
Incandescent lamp: 3,000 lx max., Sunlight 10,000 lx max.
Ambient temperature range
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Case
Operating: −10 to 55°C (with no icing and condensation), Storage: 0 to 65°C (with no icing and condensation)
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
20 MΩ min. at 500 VDC
1,000 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Destruction: 500 m/s2 3 times each in X, Y and Z directions
IEC 60529 IP67
Pre-wired Models (Standard cable length: 2 m)
Approx. 300 g
Zinc die-cast
Material Lens
Polycarbonate (PC)
Mounting Brackets
Accessories
Iron
Mounting Bracket (with screws), Screw driver for adjustment, Sensitivity adjuster, Instruction manual
Engineering Data (Typical)
Parallel Operating Range
Excess Gain vs. Set Distance
Through-beam
Through-beam
4
Y
3
2
X
100
70
50
1
30
5
10
15
20
0
-1
-2
-3
-4
Distance X (m)
10
7
5
3
Operation
1
Level
0
5
10
15
20
Distance X (m)
2
E3S-5E4S-45
I/O Circuit Diagrams
NPN output
Operation
Operation
selector
Model
mode
Timing charts
Output circuit
Through-beam Receivers
Incident light
No incident light
ON
OFF
ON
Light
indicator (red)
Output
transistor
L side
(LIGHT ON)
Light-ON
Dark-ON
---
OFF
Operate
Reset
Load 1
(relay)
12 to 24 VDC
Brown
Black
(Between brown and black leads)
Light
indicator
Stability
indicator
Z
Load 1
(relay)
H
Load 2
L
Load
(red)
(green)
(Between blue and black leads)
(relay)
Photoelectric
Load 2
Z
Sensor main
circuit
*
Incident light
Orange
Blue
No incident light
Self-diagnosis
output
ON
Z
Light
indicator (red)
OFF
0 V
ON
E3S
D side
(DARK ON)
Output
transistor
OFF
-5E4S-45
Operate
Reset
Load 1
(relay)
(Between brown and black leads)
H
Load 2
L
(Between blue and black leads)
Through-beam Emitters
Brown
Pink
12 to 24 VDC
Indicator
ON
External
-diagnosis input
OFF
(Between blue and pink leads)
Semiconductor
laser diode for
emission
Photoelectric
Sensor main
circuit
External
-diagnosis
input
ON
OFF
ON
---
Indicator
OFF
Blue
0 V
* Voltage output (when connecting a transistor circuit, etc.)
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
• The paper bag sensors are used to detect whether paper bags
contain contents inside.Note, however, that the sensors are not
available for some types of paper bags.
• About the lens The inside of the emitter lens looks cloudy. This is
due to the characteristics of the lens and not abnormal.
Use it as it is.
Inside
paper bag
Type of
paper bag
Remarks
Empty paper bags allow beam-
through while paper bags contain-
ing liquid or solid objects do not.
Detection uses this difference.
Detect-
able
Light colored
paper bags
Dark colored pa-
per bags, Paper
bags having inner
coating of alumi-
num foil
Not de-
tectable
Paper bags prevent beam-through.
Detection cannot be made.
Note: Make sure in which of the types your paper bag is categorized before use.
3
E3S-5E4S-45
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Sensors
E3S-5E4S-45
With Mounting Bracket Attached
4-dia. vinyl-insulated round cable
A*
Emitter
23
20
55
Lens: 9 × 14.3
with 3 conductors (Conductor cross
7
(5)
section: 0.2 mm2, Insulator diameter:
1.2 mm), Standard length: 2 m.
24
Power indicator
20
20.4
13 dia.
Mounting Holes
22.2
(R2.1)
4.2
Two, M4
20
Mounting
Brackets
25.4
6.5
25.4
39
5
1.6
Iron
Two mounting holes
12
10
Two, M4 slotted
hexagonal bolts
22
1.9
32
Emitter: E3S-5LE4S-45
Receiver: E3S-5DE4S-45
* The Mounting Bracket can be attached to side A.
Sensitivity adjuster
55
Operation selector
(5)
4.5-dia. vinyl-insulated round cable
with 4 conductors (Conductor cross
section: 0.2 mm2, Insulator diameter:
1.2 mm), Standard length: 2 m.
A*
23
20
Lens diameter: 11
Receiver
Light
9.5 9.5 8.5
indicator (red)
7
20
20.4
13 dia.
Mounting Holes
22.2
(R2.1)
Two, M4
Stability
indicator
(green)
20
4.2
Mounting
Brackets
25.4
6.5
25.4
39
5
1.6
Two mounting holes
12
10
Two,
22
M4 slotted
hexagonal bolts
1.9
32
* The Mounting Bracket can be attached to side A.
Accessories (Order Separately)
Mounting Brackets
Refer to E39-L/F39-L/E39-S/E39-R for details.
4
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
·
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.
相关型号:
©2020 ICPDF网 联系我们和版权申明