E3X-DA41 [OMRON]
Analog Circuit;型号: | E3X-DA41 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Analog Circuit 光纤 传感器 |
文件: | 总35页 (文件大小:5216K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CSM_E3X-DA-S_MDA_DS_E_3_1
E3X-DA-S
Digital Fiber Sensors
Perfection Transcended!
A Wealth of Advanced Functions
for Easy and Reliable Application
Evolution and Perfection
The next-generation platform for a wide range of sensing
The industry's first Power Tuning Function in a digital sensor.
Large, Easy-to-Read Displays that are clear even from a distance.
Seven convenient display formats.
Stable long-term performance achieved with
OMRON's Auto Power Control (APC) function.
A wide array of Advanced Functions for even more applications.
The same Ease-of-Use as the E3X-DA-N Amplifier.
Environmentally
Friendly design.
Improved Mobile Console.
2
3
Large, Easy-to-Read Displays: Clear Even from a Distance
Industry's First Power Tuning Function in a Digital Sensor.
Large, bright
Patent Pending
No complicated mode settings.
operation indicator
Troublesome power adjustments have been eliminated, so it isn't necessary
to select from power mode settings, such as long-distance mode, standard
mode, and short-distance mode. When the MODE Key is pressed once, the
power tuning function shifts the power level so that the present incident level
is set to the ideal level (2000 on the digital display.)
(like earlier models)
The displays are large and easy-to-read,
despite the small case.
Incident level
Threshold level
RUN mode
Incident level Threshold level
Earlier Method
New Method
Industry's largest
characters: 6 mm
(like earlier models)
Incident
Settings can be made more simply and confident-
High-speed mode
Power tuning indicator added
to indicate setting status.
insufficient
Up to 5-fold increase Press
ly with two digital displays. For example, the
threshold value can be changed while reading the
incident level or a setting can be changed while
confirming the setting's function item number.
No power modes
Short-distance mode
Standard mode
Appropriate
Appropriate
Function
Setting
Up to 1/25 reduction
SET mode
Long-distance mode
Saturated
Saturated
The Sensor can be used immediately without
setting the mode.
Function numbers
added to function
items.
Super-long-distance mode
If the incident light level is too high or too low,
just press the Mode key to achieve the optimum
status.
The best mode for each application was
selected from several power modes.
Settings are now reversible.
Insufficient light or saturation at short distances can be corrected.
The power tuning range is extended to the allowable limits to eliminate prob-
lems such as insufficient light or detection failures due to saturation.
If the installation distance is too short, the incident light may saturate (i.e., to
a digital incident level of 4,000), preventing detection. The power can be
tuned down to 1/25th of the default setting for stable detection even at close
range.
Patent Pending
Seven Convenient Display Formats
Press
An incident level/threshold display, percentage/threshold display, and large bar graph display
have been added, so you can select the best display method for the application.
Without workpiece
Incident level
Large Bar Graph Display
Percentage/Threshold Display
Incident Level/Threshold Display
Incident level changes.
does not change.
Transparent workpiece
Incident light
No incident light
Incident level
Threshold level
Incident level
Threshold level
Detection is not possible
Bar display
Detection is possible.
With workpiece
Change the threshold level while read-
ing the incident level.
Verify the difference between the inci-
dent level and threshold level while set-
ting the threshold level.
Check the incident level intuitively. Ideal
when it is better to view an analog dis-
play instead of the actual digital level.
Variations between different Sensors can be eliminated.
Threshold levels had to be set and maintained separately for individual Sen-
sors due to variations in the digital light levels measured by each Sensor.
With power tuning, the incident level can be fine-tuned so the same thresh-
old level can be set for each Sensor in an application. Maintenance is also
simplified because it is easier to recognize measurement levels that have
shifted during operation.
Incident Level/Peak Hold Display
Peak Hold/Bottom Hold Display
2055
2010
Press
Incident level
Peak hold
Earlier Method
New Method
Threshold
level
1350
1280
Simultaneously display the peak hold level and
present incident level. The optical axis can be
adjusted more easily and surely by checking the
peak hold level while adjusting the optical axis.
Display the peak level when light was brightest and bottom level when light was
dimmest. The digital levels of high-speed objects can be read precisely.
(Refreshing the hold level was changed from a fixed time to synchronizing with
the output, so the peak and bottom hold values can be checked with certainty.)
Detecting missing tablets
Digital light levels vary due to individual
differences in the Sensors, so the
threshold levels must be set individually.
All of the Amplifiers are set to the same digi-
tal light level, so the same threshold level
can be set and maintained for the Sensors.
4
5
Stable, Long-term Performance with OMRON's APC Function
Many Advanced Functions for Even More Applications
Fastest in the Industry
Detecting Leads on Electronic Parts
Highest Level of Stability
OMRON provides the industry's most stable long-term detection
by using new 4-element LEDs and an APC (Auto Power Control) circuit.
Provides high-speed response for miniature workpieces, such as chip parts and devices with short tact times.
In addition to our unique APC circuit used in the
Earlier Method
New Method
Three kinds of timer functions are supported. The timers can be set between 1 ms and 5 s.
A one-shot timer is supported in addition to the ON-delay and OFF-delay timers.
The Amplifier's ON time can be fixed, which is useful during high-speed workpiece detection.
E3X-DA-N Amplifiers to compensate for the dete-
rioration of the LED, the E3X-DA-S uses 4-ele-
ment LEDs to counteract the deterioration of the
light-emitting elements over time and achieve the
industry's most stable long-term detection perfor-
mance.
3-element LED and APC
4-element LED and APC
Long-term stability
Furthermore, the circuit is designed with excess
light capacity, so the Sensors can be used with
high stability regardless of whether the APC cir-
cuit is ON or OFF.
Discriminating Tablet Lengths
Area output
Area output function can be
used for range judgement.
(Advanced Twin-output Models)
Without APC circuit
Without APC circuit
Incident
level
Time
Time
2000
1000
Threshold 1
Threshold 2
Operations that required multiple Sensors, such as
height measurement, can be performed with just one
Sensor. Two threshold levels can be set to easily output
within-range and out-of-range outputs.
Compensate for the effects of contaminants and temperature variation
with differential operation mode. (Advanced Models)
Time
Output
ON
OFF
This operation mode uses a special OMRON algorithm to compensate for slight light level changes
due to dirt or temperature variations and detect only the light level changes due to the workpiece.
Detecting Seals
Slight light level changes can be detected with stability and
precision, eliminating the need for time-consuming manual ad-
justments for light level changes.
Remote input function can control the Sensor remotely.
(Advanced External-input Models)
Input signals can make various remote settings, such as teaching operations, power tuning, and emitter
OFF. This model is ideal for diverse needs, such as checking Sensor operation remotely before operation
or making settings remotely because teaching has to be performed often for frequent workpiece model
changes.
Detecting marks in a dusty environment
With the Twin-output Amplifiers, output 2 can function as an
alarm output (light level operation) to indicate when the light
level has changed due to dirt or other causes.
Patent Pending
Light Level Operation
Patent Pending
The counter function can output signal after counter
(Normal Operation)
Differential Operation
counts up or down.
Counter Function
Judges light level changes by comparing
the incident level and threshold level.
Judges light level changes by comparing the
incident level to a time-averaged incident level.
Detecting Chip Components
(Advanced External-input Models)
Up Counter
Down Counter
Incident
level
Incident
level
A counter function is built-in, so the number
of workpieces can be counted without a sep-
arate counter or small PLC that used to be
required.
Threshold
level
Alarm output
Detecting knots in thread
Time
Time
Time
Threshold level
(absolute value)
Counter
Counter
Counter
value
Alarm output
Incorrect operation due to light level change
Light level difference
threshold
(absolute value)
Time
Time
Time
The light level varies due to dirt, temperature
variations, or other environmental factors.
Detecting differences in the light level enables
setting more subtle light level differences.
Incorrect operation
Minute changes are
detected reliably.
Output when count reaches SV.
Output when count reaches 0.
6
7
The Same Ease-of-Use as the E3X-DA-N
Environmentally Friendly Design
The E3X-DA-S uses OMRON's own
Environmentally friendly features are
essential in truly high-performance products.
Simplified Connector Design
Reduced Power Wiring Saves Space
simplified wiring connectors that
were introduced with the E3X-DA-N.
Up to 16 Amplifiers can be connected.
<Using 5 Amplifiers>
Connector models
Relay connectors
not required.
Power is supplied
from the master
Amplifier Unit to
the slave Amplifier
Units through the
Master Connector.
Patent Pending
Japan patent number 3266198
First in the industry
1 Materials containing lead have been completely eliminated.
7 cables
Streamlined
wiring
In Amplifiers with Connectors, the power supply is dis-
tributed to slave connectors through a single master
connector. This design has three major advantages.
Eliminate the installation time, cost, and
space associated with relay connectors.
Prewired models
The Fiber Sensor is the first in the industry
to use environmentally friendly lead-free
solder.
Separate power
lines and output
lines are required
for each Amplifier.
Optical
commun-
ications
1. Wiring time is significantly reduced.
15 cables
No lead!
Pb
2. Relay connectors are unnecessary, so wiring takes up less space.
3. Storage and maintenance are simpler because it isn't necessary to distin-
guish between master connector and slave connectors on the Amplifier.
Power supply pin
Master connector
Relay connectors
Slave connector
This ECO label is indicated on produts
that meet the environmental standards
established by OMRON.
Optical communications
prevents mutual interference.
Mutual interference is prevented with optical com-
munications, so up to 10 Amplifiers can be mount-
ed together.
(The number of Amplifiers depends on the operating conditions.)
Optical
communi-
cations
2 The digital display can be turned OFF or dimmed during operation. Eco-mode
Up to 10 Amplifiers
Close-mounting of up to 10 Sensors
When the digital display is viewed infre-
quently during operation, current con-
Display not lit.
Dimmed display
sumption can be reduced by dimming the
display or turning it OFF entirely.
The display will light up again automatical-
ly when an operation key is touched. (Eco-
mode can be set from the Mobile Console
only.)
Zero reset function immediately
resets the digital display to 0.
With Workpiece
Without Workpiece
Lights up if an
operation is
performed.
Lights up if an
operation is
performed.
During operation
(After 30 s without
an operation)
During operation
(After 30 s without
an operation)
Patent Pending
Japan patent number 3255229
Shift
Zeroo resseett
The zero reset function can immediately reset the
digital display to 0 at any time. By setting the ref-
erence value to 0, the threshold value can be set
while monitoring differences in incident light lev-
els. The threshold value will also shift simultane-
ously when the zero reset button is pressed.
Incident level
difference = 700
Display reset to 0.
Threshold level
set to 350.
3
Cable disposal is not required during maintenance.
In addition to saving space and reducing
wiring time, the new connector design
eliminates the need to dispose of cables
together with the Amplifiers.
Reversible Digital Display (Reverse Mode)
The digital display can be reversed to match the
Amplifier's mounting direction.
Standard mode
Selectable
Cable disposal is not necessary.
Reverse mode
8
9
New and Improved
Fiber Sensor and
Mobile Console.
Further Improvements to the Mobile Console
Retains all of the Previous Advantages of the Mobile Console.
Can also be used with Photoelectric Sensors with Separate Digital Amplifiers.
Settings, teaching, and fine-tuning
can be performed at the fiber tip.
The Mobile Console can be used for settings and teaching at
the tip of the fiber. Difficult adjustments can be made while
checking the workpiece position.
Even if the Amplifier and Sensor head are separated during
operation, it is still possible to flash the Sensor head and dis-
play the amplifier channels.
E3X-DA-S
Digital Fiber Sensor
Channel
Channel
Channel
Channel
5
4
3
2
Channel
1
E3C-LDA
Photoelectric Sensor with Separate Digital Amplifier
With Group Teaching, Teach Multiple
Amplifiers Simultaneously.
E3X-MC-S
Group teaching
Mobile Console
Easily set
multiple Sensors.
The tedious teaching that had to be performed separately for
each Amplifier can now be performed for several Amplifiers at
once using the Mobile Console.
Group Power Tuning
With the group power tuning function, power tuning is possible
for multiple Sensors at the same time.
Copy channel 1's
Channel 1
Channel 2
All channels
Copying Settings within the Same Group
contents to all channels.
Channel 1
Channel 5
Settings such as mode or threshold settings in an Amplifier or
bank can be copied to all of the Amplifiers in the same group.
Group Power Tuning
The Age of User-
customizable Sensors.
Improved Mode Lock Function
Settings can be customized for different applications by locking
out unnecessary function blocks within function settings.
All of the group's
Machine A
Machine B
Copying Settings to Other Groups
settings are copied.
Function Block
The settings for a group of Amplifiers on one machine can be
copied to a group of Amplifiers on another machine.
(The settings can also be copied to and from banks.)
Application
Manual setting
Teaching
Function setting
Set for manual operation.
Operation OK
Locked
Locked
Manual
Machine D
Set for teaching operation.
Locked
Operation OK
Operation OK
Locked
Locked
Teaching
Set for teaching
+
Operation OK
Manual
Teaching
+
manual operation.
10
11
OMRON Corporation
Industrial Automation Company
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit,
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173
U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON CHINA CO., LTD. BEIJING OFFICE
Room 1028, Office Building,
Beijing Capital Times Square,
No. 88 West Chang'an Road,
Beijing, 100031 China
Tel: (86)10-8391-3005/Fax: (86)10-8391-3688
In the interest of product improvement, specifications are
subject to change without notice.
Authorized Distributor:
This document provides information mainly for selecting
suitable models. Please read the Instruction Sheet
carefully for information that the user must understand
and accept before purchase, including information on
warranty, limitations of liability, and precautions.
CSM_E3X-DA-S_MDA_DS_E_3_1
CSM_E3X-DA-S_MDA_DS_E_3_1
E3X-MDA
Super Dual Fiber Sensor
Bringing a new dimension to sensing…
This document provides information mainly for selecting suitable models.
Please read the Instruction Sheet carefully for information that the user must understand and accept before purchase, including
information on warranty, limitations of liability, and precautions.
Regional Headquarters
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
OMRON EUROPE B.V.
Sensor Business Unit, Carl-Benz-Str. 4,
D-71154 Nufringen, Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
Sensing Devices Division H.Q.
Industrial Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7022
Fax: (81)75-344-7107
…the 2-channel amplifier has arrived.
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173 U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue, #11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Road (M),
Shanghai, 200120 China
Tel: (86)21-5037-2222/Fax: (86)21-5037-2200
CSM_E3X-DA-S_MDA_DS_E_3_1
In the interest of product improvement, specifications are subject to change without notice.
Patent pending
Slimmest in the industry — 5 mm per channel.
Two Amplifiers squeezed into a body of width
10 mm.
Remarkable space saving of approx. 50%.
Power saving of approx. 40%.
Having problems gang-mounting Fiber Sensor Amplifier Units
in tight spaces?
Checking alignment and mounting
of LCD substrates
(Savings per channel compared with
existing products.)
100 mm
10 mm
Emitting
2 ch
1 ch
Receiving
Emitting
Receiving
Patent pending
Equipped with AND/OR control output.
Two types of control output possible with one
Sensor (AND/OR).
Compact PLCs and Sensor Controllers no
longer required.
Detection and front/back
discrimination of parts
Half the Space
Detection of bends in electronic
component leads
Compact PLC
or
Sensor Controller
Operation
indicator
Channel 1
display
Incident level
AND/OR
AND/OR
Operation
indicator
Channel 2
display
Incident level
Flexible control with Mobile Console.
The Mobile Console, which can also be used with the E3X-DA-S,
allows handheld operation of the Fiber Head even when it is
separated from the Amplifier.
50 mm
An impressive lineup of Digital Amplifiers to
handle a wide variety of applications.
A host of remarkable functions inside a compact body.
A complete lineup of Sensor Heads to handle an even wider
range of applications.
This is the platform for OMRON's sensing technology.
The Digital Amplifiers achieve a maximum response time of 48 µs.
Standard Models
(E3X-DA11-S)
Models with Cables
(E3X-DA6-S)
Laser-type Smart Sensors
ZX-L Series
Inductive Displacement
Smart Sensors
Models with Connectors
Linear Platform
Equipped with OMRON's own easy-wiring connector.
ZX-E Series
High-resolution sensing using laser
and magnetic technology
Advanced Models
(Representative model: E3X-DA6TW-S)
Twin-output Models
Two threshold values can be set. Judgement and self-diagnosis
output available.
(Representative model:
E3X-DA6RM-S)
External-input Models
The Sensor can be controlled externally. Equipped with counting function.
Smart Monitor
A wide variety of color variations available. Equipped
with APC circuit for more stable detection.
A lineup of Smart Sensors that use
the eddy current method
An improved lineup for smarter sensing
Mark-detecting Models and Infrared Models
(Representative model:
Models with Green LED
E3X-DAG6-S)
(Representative model:E3X-DAB6-S)
Models with Blue LED
Digital Fiber Sensors
E3X-DA-S/MDA Series
Laser-type Photoelectric Sensors
with Separate Amplifiers
E3C-LDA Series
ON/OFF Platform
(Representative model:E3X-DAH6-S)
Available Soon
A common platform for Fiber Sensors
and Sensors with Separate Amplifiers
Infrared Models
Two Amplifiers squeezed into a single, compact Unit.
AND/OR output available.
NEW
2-channel Models
(Representative model:E3X-MDA6)
Mobile Console
Maximize Fiber Amplifier potential using remote setting,
copying, and other functionality.
Refinement and a new dimension that
goes beyond superior performance.
Photoelectric Sensors with Separate
Digital Amplifiers have joined the Smart
Sensor family.
Mobile Console
(E3X-MC11-S)
CSM_E3X-DA-S_MDA_DS_E_3_1
New Models That Counteract the Decline
in Operating Rates Caused by Dust and Dirt
Advanced ATC Models
■ Active Threshold Control (ATC)
Automatically adjusts the threshold value.
■ ATC Error Output (Selectable Function)
Provides an error output when ATC does not adjust
the threshold value.
Digital Laser Sensors
E3C-LDA@AT
■ Alarm Output (Selectable Function)
Provides an alarm when maintenance is required.
Digital Fiber Sensors
E3X-DA@AT-S
Glass substrate detection though
view ports
Chip component detection
Technology
The
Sensing
Engine for High-performance
Intelligently Solve Problems Onsite with
ATC Function
A unique OMRON algorithm has been used that can determine whether
changes have been caused by dust and dirt or by differences in
workpieces.
OMRON's many years of accumulated sensing technology and high-
speed digital processing techniques merge to meet onsite needs. Our
goal is high-performance sensing that provides easy, reliable application.
The threshold value is automatically adjusted by the Sensor according
to changes to increase equipment operating rates by reducing sensing
errors. This is particularly true in applications requiring high-precision
detection.
Reliable Detection of Small Workpieces
12-bit A/D converter (4,000 resolution),
high-speed response of 48 µs (Fiber Sensors)
■ Fixed Threshold Value (Previous Models)
2000
1800
An absolute value
is set for the threshold.
Automatic Compensation for
Digital incident
level
Fine Sensing
External Changes
Active Threshold Control (ATC)
Adjustment is required for sensing errors.
Time
Consistent Emitter Power
Auto Power Control (APC)
ON
Output
OFF
High Performance
Sensing Engine
■ Active Threshold Control (ATC Models)
2000
−10%
A relative value
is set for the threshold.
Digital incident
level
Easy Operation
The value of the threshold is
adjusted every 30 s (see note) to prevent sensing errors.✽
Easy-to-read Displays Even at a Distance
Intelligent Display
Time
ON
Output
OFF
Eliminates the Need for Distance Mode Settings
Power Tuning
The monitoring range is set in the Sensor according to the thresh-
old value. The threshold value is adjusted according to changes
within this range.
✽
Ordering Information
■ Digital Fiber Sensor
Model
Type
Appearance
Functions
NPN output
PNP output
Pre-wired Models
E3X-DA11AT-S
E3X-DA41AT-S
ATC
ATC error output
Alarm output
Connector Models
E3X-DA6AT-S
E3X-DA8AT-S
■ Separate Digital Amplifier Laser Sensors
Model
Type
Appearance
Functions
NPN output
PNP output
Pre-wired Models
E3C-LDA11AT
E3C-LDA41AT
ATC
ATC error output
Alarm output
Connector Models
E3C-LDA6AT
E3C-LDA8AT
Ratings and Specifications
Model
Digital Fiber Sensors
Separate Digital Amplifier Laser Sensors
NPN output
Type
E3X-DA11AT-S
E3X-DA6AT-S
E3X-DA8AT-S
E3C-LDA11AT
E3C-LDA6AT
E3C-LDA8AT
PNP output
Super-high-speed mode
High-speed mode
Standard mode
High-resolution mode
ATC
E3X-DA41AT-S
E3C-LDA41AT
Item
Operate or Reset: 80 µs
Operate or Reset: 250 µs
Operate or Reset: 1 ms
Operate or Reset: 4 ms
Operate or Reset: 100 µs
Operate or Reset: 250 µs
Response
time
Active threshold control (used for output 1)
The signal that is output can be selected (used for output 2): ATC error output
Functions I/O settings
Startup operation
The operation when power is turned ON can be selected: No operation, PT, or PT + ATC
Note:
Basic performance is the same as the Advanced Twin-output Sensors. Refer to E3C-LDA Datasheet (E338) and E3X-DA-S Datasheet (E336) for details.
Only differences from the Advanced Twin-output Sensors have been given above.
This document provides information mainly for selecting suitable models.
Please read the Instruction Sheet carefully for information that the user must
understand and accept before purchase, including information on warranty,
limitations of liability, and precautions.
Note: Do not use this document to operate the Unit.
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg,
IL 60173 U.S.A.
OMRON Corporation
Authorized Distributor:
Industrial Automation Company
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit,
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
OMRON CHINA CO., LTD. BEIJING OFFICE
Room 1028, Office Building,
Beijing Capital Times Square,
No. 88 West Chang'an Road,
Beijing, 100031 China
Tel: (86)10-8391-3005/Fax: (86)10-8391-3688
Note: Specifications subject to change without notice.
CSM_E3X-DA-S_MDA_DS_E_3_1
CSM_E3X-DA-S_MDA_DS_E_3_1
New Models That Eliminate Worries about
Digital Sensor Setting Mistakes
Limited-function Models: Simple and Easy
Easy and Reliable Digital Sensors
with the Same Detection Performance
as Previous Models
■ One-key, one-operation concept for easy operation.
■ Threshold value setting with direct operation performed
Digital Fiber Sensors
E3X-DA@SE-S
while monitoring the detection status.
■ Lock function to prevent operating errors through
unintentional operation.
Technology
The Simplest Digital Fiber Sensor
The
Engine for High-performance
Sensing
OMRON's many years of accumulated sensing technology and high-
speed digital processing techniques merge to meet onsite needs.
Our goal is high-performance sensing that provides easy, reliable
application.
Some people think that digital sensors with their advanced performance
are difficult to use, so we went back to the drawing board to rethink per-
formance and functions.
Without changing basic functions like APC and digital displays, OMRON
created a Digital Fiber Sensor that can be used as easily as the familiar
sensors with sensitivity adjustment knobs.
Reliable Detection of Small Workpieces
12-bit A/D converter (4,000 resolution)
UP/DOWN Key
Threshold adjustment
Fine Sensing
Consistent Emitter Power
Auto Power Control (APC)
Incident level Threshold value
High Performance
Sensing Engine
KEY LOCK Switch
OPERATION MODE Selector
TEACH Key
Easy Operation
Threshold Teaching
With/Without Workpiece: Teaching is performed in two states.
Automatic: Teaching is performed by passing a workpiece.
Easy-to-read Displays Even at a Distance
Intelligent Display
One Key, One Operation
Simple and easy direct operation
Ordering Information
Model
Type
Appearance
NPN output
PNP output
Pre-wired Models
Connector Models
E3X-DA11SE-S
E3X-DA41SE-S
E3X-DA6SE-S
E3X-DA8SE-S
Ratings and Specifications
Model
NPN output
PNP output
Digital Fiber Sensor
E3X-DA11SE-S
E3X-DA6SE-S
E3X-DA8SE-S
Type
E3X-DA41SE-S
Item
Light source (wavelength)
Power supply voltage
Power consumption
Control output
Red LED (650 nm)
12 to 24 VDC 10%, ripple (p-p): 10% max.
960 mW max. (Power supply: 24 V, Current consumption: 40 mA max.)
Load power supply: 26.4 VDC max., Open-collector output, Load current: 50 mA max. (Residual voltage: 1 V max.)
Power supply reverse polarity protection, Output short-circuit protection
Operate or Reset: 1 ms
Protection circuits
Response time
Sensitivity setting
Auto power
Teaching or manual adjustment
High-speed control method for emission current
Optical communications sync, possible for up to 10 Units
Operation indicator (orange)
control
Functions
Mutual interference
prevention
Indicators
Digital displays
Twin digital displays (incident level + threshold)
Note: Basic performance is the same as the E3X-DA-S Series. Refer to the E3X-DA-S Datasheet (E336) for details.
This document provides information mainly for selecting suitable models.
Please read the Instruction Sheet carefully for information that the user must
understand and accept before purchase, including information on warranty,
limitations of liability, and precautions.
Note: Do not use this document to operate the Unit.
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg,
IL 60173 U.S.A.
OMRON Corporation
Authorized Distributor:
Industrial Automation Company
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
239920 Singapore
Tel: (65)6835-3011/Fax: (65)6835-2711
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit,
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49)7032-811-0/Fax: (49)7032-811-199
OMRON CHINA CO., LTD. BEIJING OFFICE
Room 1028, Office Building,
Beijing Capital Times Square,
No. 88 West Chang'an Road,
Beijing, 100031 China
Tel: (86)10-8391-3005/Fax: (86)10-8391-3688
Note: Specifications subject to change without notice.
CSM_E3X-DA-S_MDA_DS_E_3_1
Digital Fiber Sensors
E3X-DA-S/MDA
CSM_E3X-DA-S_MDA_DS_E_3_1
OMRON’s Next-generation Platform
for a Wide Range of Detection
• Features a Power Tuning function that optimizes light reception at
the press of a button.
• Combines newly developed 4-element LEDs with an APC circuit to
ensure stable, long-term LED performance.
• Utilizes OMRON’s innovative wire-saving connector.
• 2-channel models achieve the thinnest profile in the industry, at only
5 mm per channel.
• 2-channel models also offer AND/OR control output.
Be sure to read Safety Precautions on
page 15.
Features
Equipped with an Industry’s First Power Tuning (Optimum Light Setting) Function
The E3X-DA-S/MDA features a Power Tuning function that optimizes
power at the press of a button.
Conventional
New proposal
Incident level Threshold
This function easily but securely resolves saturation due to short
sensing distances or insufficient incident light due to long sensing
distances.
In addition, the response speed does not change as mode selection
has tuned the power.
Incident
Press
High-speed mode
Short-range mode
level Low
Up to approx.
5 times
Appropriate
Appropriate
Modeless
Standard mode
Long-range mode
Up to approx. 1/25 times
Saturation
Saturation
Available without mode setting.
Press the MODE key once to
adjust high or low incident levels
to be appropriate.
Super-long-range mode
Selected from various
power mode according to applications
Adoption of Newly Developed 4-Element LEDs and an APC (Auto Power Control) Circuit
Achieves Long-term Reliable Detection at the Highest Level in the Industry
The long-term reliable detection at the highest level in the industry is
Conventional
Newly developed
achieved with the innovative APC circuit whose performance is
proved by E3X-DA-N series and the newly developed high-power
LEDs (4-element type) to ensure super stable, long-term LED
performance.
3-element LEDs + APC
4-element LEDs + APC
Long-term
stability
Stable performance is always available without the ON/OFF setting of
an APC circuit.
No APC circuit
No APC circuit
Time
Time
OMRON’s Innovative Wire-saving Connector Inherited from the E3X-DA-N
The amplifier units with connectors supply the power to slave
connectors via a master connector. This offers three following
advantages.
Wire-saving Connector Model
Up to 16 amplifier units connectable
Reduced Wiring and Space Requirements for Power Lines
<When using 5 amplifier units>
No relay connector required
Amplifier units with connectors
The power is
supplied from a
master unit to
slave units via a
master connector.
7 lines
1. Greatly reduced wiring work
Clear
2. Improved space usability due to the unnecessity of relay
connectors
3. Simple stock management due to the unnecessity of
distinction between master and slave for amplifiers
Relay connector installation work, cost and space are saved.
Amplifier units with cables
Power and output
lines are required
respectively.
Optical
communications
Power supply pin
15 lines
Master connector
Slave connector
Relay connector
1
E3X-DA-S/MDA
Models available for a wide variety of applications at manufacturing sites
. . . .
Industry Leading Two Amplifiers Loaded in a Small Body
2-channel models
Two amplifiers are loaded in a 10 mm-wide body.
Space usability can be approximately doubled.
In addition, approximately 40% of the energy can be
saved.
Liquid crystal board installation and alignment check
(compared to the value per channel of the former
model)
2-channel models
E3X-MDA
20mm
10mm
. . . .
UP/DOWN keys
Threshold value adjustment
Simpler Digital Fiber Sensors
Simple & Easy Single-function Models
Current value Threshold value
Required performance and functions have been reviewed from basic points to improve high-performance
but hard-to-use digital models. Digital fiber sensors, used in the sense as if using volume type sensors,
are added to the basic functions such as an APC function and digital display.
Key lock switch
Operation mode
selection switch
TEACH key
Threshold value teaching
Yes/No: Teaching at two points to be detected
Automatic: Automatic teaching by feeding workpieces
. . . .
Advanced Analog
Output Models
High-speed and High-resolution Analog Output Supports Wide Variety of Applications
Analog Control Output
High-speed and High Resolution
The voltage in the range of 1 to 5 V is output according to the incident
level (digital display). Wide variety of applications is possible including
positioning control or difference detection with multiple levels.
Detection modes can be switched in accordance with applications.
High-speed response of 80 µs (super-high-speed mode) supports the
positioning controls that require high-speed control.
Sheet Displacement
ON/OFF
Analog
Area Output Function Area Judgment Is
Area Output
Incident
level
Tablet length detection
. . . .
Possible
Advanced, Twin-output Models
2000
1000
Threshold
value 1
Only one sensor is enough for area judgment for height or others that
has required multiple sensors.
Threshold
value 2
Setting two threshold values allows easy output inside and outside
range.
Time
Output
ON
OFF
. . . .
Advanced, External-
Remote Input Function Sensors Controlled from Outside
Sticker detection
input Models
Remote settings for teaching/power tuning/light OFF are possible with input signals.
The remote input function meets the diversifying demands such as remote settings made for frequent teaching
due to level change corresponding to workpiece change or remote operation check of sensors before operation.
Equipped with an Industry's First ATC Function that Resolves Problems
. . . .
Advanced ATC Models
at Manufacturing Sites
OMRON’s unique algorithm is equipped to
Fixed Threshold Value Method (Conventional Models)
Corrected Threshold Value Method (ATC Models)
distinguish dust or dirt and the change of
workpieces. Automatic correction of threshold
values by sensors in accordance with changes
prevents malfunctions and improves the
operating rates of machines. The ATC function
is especially effective for the applications that
require high-resolution detection.
Threshold value
2000
2000
−10%
1800
set as a relative
value
Threshold value
set as an
Incident level
(digital value)
Incident level
absolute value
(digital value)
Threshold value is corrected every 30 seconds
Malfunctions are prevented
*
Malfunction Adjustment is required
Time
Time
ON
Output
OFF
ON
Output
OFF
*
Monitoring range is defined in sensors according to threshold
values. Threshold values are corrected in this definition range.
2
E3X-DA-S/MDA
Ordering Information
Amplifier Units
Amplifier Units with Cables (2 m) [Refer to Dimensions on page 17.]
Model
Item
Single-function models
Appearance
Functions
NPN output
PNP output
---
E3X-DA11SE-S 2M
E3X-DA41SE-S 2M
Standard models
E3X-DA11-S 2M
E3X-DAG11-S 2M
E3X-DAB11-S 2M
E3X-DAH11-S 2M
E3X-DA41-S 2M
E3X-DAG41-S 2M
E3X-DAB41-S 2M
E3X-DAH41-S 2M
Green LED
Blue LED
Infrared LED
Timer, Response speed change
Mark-detecting models
(multiple color light sources)
External-input
models
Remote setting, counter, differential oper-
ation
E3X-DA11RM-S 2M
E3X-DA11TW-S 2M
E3X-DA11AT-S 2M
E3X-DA11AN-S 2M
E3X-DA41RM-S 2M
E3X-DA41TW-S 2M
E3X-DA41AT-S 2M
E3X-DA41AN-S 2M
Twin-output
models
Area output, self-diagnosis, differential
operation
Advanced models
ATC function
models
ATC (Threshold value automatic correc-
tion)
Analog output
models
Analog output models
2-channel models
AND/OR output
E3X-MDA11 2M
E3X-MDA41 2M
Amplifier Units with Connectors
Model
Item
Appearance
Functions
NPN output
E3X-DA6SE-S
E3X-DA6-S
PNP output
E3X-DA8SE-S
E3X-DA8-S
Single-function models
Standard models
Green LED
---
E3X-DAG6-S
E3X-DAB6-S
E3X-DAH6-S
E3X-DAG8-S
E3X-DAB8-S
E3X-DAH8-S
Timer, Response speed change
Mark-detecting models
(multiple color light sources)
Blue LED
Infrared LED
External-input
models
Remote setting, counter, differential op-
eration
E3X-DA6RM-S
E3X-DA6TW-S
E3X-DA6AT-S
E3X-DA8RM-S
E3X-DA8TW-S
E3X-DA8AT-S
Twin-output
Advanced models
Area output, self-diagnosis, differential
operation
models
ATC function
models
ATC (Threshold value automatic correc-
tion)
2-channel models
AND/OR output
E3X-MDA6
E3X-MDA8
Ratings and Specifications
Control output/input
Functions
Response
time
Interfer-
ence pre-
vention
Differen-
tial detec- counter ATC
tion
Light source
ON/OFF
output
Analog
output
Power
tuning
Input
Timer
Single-function models
Standard models
1 ms
50 µs to
4 ms
---
---
Only
main
Red LED
---
---
---
---
---
---
---
---
---
E3X-DA@G-S
detecting 3X-DA@B-S
Green LED
Blue LED
Mark-
50 µs to
4 ms
Only
main
---
models
E3X-DA@H-S
Infrared LED
Twin-output
models
50 µs to
4 ms
Only
main
(1 line)
---
External-input
80 µs to
---
Ad-
Main +
sub
models
4 ms
vanced
Red LED
Red LED
ATC function
models
130 µs to
4 ms
80 µs to
4 ms
(2 lines)
---
---
---
---
models
Only
main
Main +
main
(2 inde-
pendent
lines)
Analog output
---
---
---
---
(1 line)
---
130 µs to
4 ms
2-channel models
3
E3X-DA-S/MDA
Amplifier Unit Connectors (Order Separately)
Note: Protector seals are provided as accessories. [Refer to Dimensions on page 19.]
Cable
length
No. of con-
ductors
Item
Appearance
Model
E3X-CN11
E3X-CN21
E3X-CN12
E3X-CN22
3
4
1
2
Master Connector
2 m
Slave Connector
Combining Amplifier Units and Connectors
Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order.
Amplifier Unit
NPN output
Applicable Connector (Order Separately)
Model
PNP output
E3X-DA8SE-S
E3X-DA8-S
Master Connector
Slave Connector
Single-function models E3X-DA6SE-S
Standard models
E3X-DA6-S
E3X-DAG6-S
E3X-DAB6-S
E3X-DAG8-S
+
E3X-CN11
E3X-CN12
E3X-CN22
Mark-detecting models
(multiple color light
sources)
E3X-DAB8-S
E3X-DAH6-S
E3X-DA6TW-S
E3X-DA6RM-S
E3X-DA6AT-S
E3X-MDA6
E3X-DAH8-S
E3X-DA8TW-S
E3X-DA8RM-S
E3X-DA8AT-S
E3X-MDA8
Advanced models
2-channel models
E3X-CN21
When Using 5 Amplifier Units
Amplifier Units (5 Units)
+
1 Master Connector + 4 Slave Connectors
Mobile Console (Order Separately) [Refer to Dimensions on page 20.]
Appearance
Model
Remarks
Mobile Console with Head,
Cable, and AC adapter pro-
vided as accessories
E3X-MC11-SV2
(model number of set)
E3X-MC11-C1-SV2
E3X-MC11-H1
E39-Z12-1
Mobile Console
Head
Cable (1.5 m)
Note: Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S/MDA-series Amplifier Units.
The E3X-MC11-SV2 is an upgraded version of the E3X-MC11-S that is fully interchangeable with the older model.
Accessories (Order Separately)
Mounting Bracket [Refer to E39-L/F39-L/E39-S/E39-R.]
End Plate [Refer to PFP-@.]
Appearance Model
Appearance
Model
Quantity
Quantity
E39-L143
1
PFP-M
1
4
E3X-DA-S/MDA
Ratings and Specifications
Refer to pages 17 to 20 for dimensions.
Amplifier Units
Mark-detecting models (multiple color light sources)
Single-function
Standard
models
Type
models
Green LED
Blue LED
Infrared LED
Item
Model
E3X-DA@SE-S
E3X-DA@-S
E3X-DAG@-S
E3X-DAB@-S
E3X-DAH@-S
Infrared LED
(870nm)
Light source (wavelength)
Red LED (635 nm)
Green LED (525 nm) Blue LED (470 nm)
Power supply voltage
Power consumption
12 to 24 VDC ±10%, ripple (p-p) 10% max.
960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Control output
Protection circuits
Reverse polarity for power supply connection, output short-circuit
Super-high-
speed mode
---
Operate: 48 µs, reset: 50 µs *1, *2
Operate/reset: 250 µs
High-speed
mode
Re-
---
sponse
time
Standard mode
Operate or reset: 1 ms
---
High-resolution
mode
Operate or reset: 4 ms
Sensitivity setting
Power tuning
Teaching or manual method
---
Light emission power and reception gain, digital control method
Select from OFF-delay, ON-delay, or one-shot timer.
Timer function
---
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Automaticpower
control (APC)
Func-
tions
High-speed control method for emission current
Zero-reset
Initial reset
---
Negative values can be displayed. (Threshold value is shifted.)
Settings can be returned to defaults as required.
Mutual interfer-
ence prevention
Possible for up to 10 Units *3
Operation indicator
Display
Operation indicator (orange), Power Tuning indicator (orange)
(orange)
incident level +
threshold
Digital display
Select from incident level + threshold or other 6 patterns
Switching between normal/reversed display is possible.
Display orientation
---
Ambient illumination
(Receiver side)
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Operating:Groups of 1 to 2 Amplifiers: −25°C to 55°C
Groups of 3 to 10 Amplifiers: −25°C to 50°C
Ambient temperature range
Groups of 11 to 16 Amplifiers: −25°C to 45°C
Storage: −30°C to 70°C (with no icing or condensation)
Ambient humidity range
Insulation resistance
Dielectric strength
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
Shock resistance
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
IEC 60529 IP50 (with Protective Cover attached)
Pre-wired or amplifier unit connector
Degree of protection
Connection method
Weight (packed state)
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Case
Materials
Cover
Polycarbonate (PC)
Accessories
Instruction manual
*1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
and the Mobile Console will not function.
*2. PNP output is as follows: Operate: 53 µs, reset: 55 µs.
*3. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
5
E3X-DA-S/MDA
Advanced models
Type
2-channel models
External input mod- Twin output mod- ATC function mod- Analog output mod-
els
els
els
els
Item
Model
E3X-DA@RM-S
E3X-DA@TW-S
E3X-DA@AT-S
E3X-DA@AN-S
E3X-MDA@
Light source (wavelength) Red LED (635 nm)
Power supply voltage
Power consumption
12 to 24 VDC ±10%, ripple (p-p) 10% max.
1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
ON/OFF output
Control output
Voltage output: 1 to
5 VDC
(Connection load
10 kΩ min.)
Temperature charac-
teristics
0.3%F.S./°C
Con-
trol
output
Response speed/re-
Analog output
---
peat accuracy
Super-high-speed
mode:
---
80 µs/1.5%F.S.
High-speed mode:
250 µs/1.5%F.S.
Standard mode:
1 ms/1%F.S.
High-resolution mode:
4 ms/0.75%F.S.
Remote control input
Protection circuits
No-voltage input (contact/non-contact) *1
Reverse polarity for power supply connection, output short-circuit
Super-high-
speed mode
Operate: 48 µs,
reset: 50 µs *2, *3, *4 80 µs *2
Operate or reset:
Operate or reset:
130 µs *2
Operate or reset:
80 µs *2
Operate or reset:
130 µs *2, *5
High-speed
mode
Operate or reset:
450 µs
Re-
sponse
time
Operate or reset: 250 µs
Standard mode Operate or reset: 1ms
High-resolution
Operate or reset: 4ms
mode
Sensitivity setting
Power tuning
Teaching or manual method
Light emission power and reception gain, digital control method
Switchable between single edge and double edge detection mode
Single edge: Can be set to 250 µs, 500 µs, 1 ms, 10 ms, or 100 ms.
Double edge: Can be set to 500 µs, 1 ms, 2 ms, 20 ms, or 200 ms.
Differential de-
tection
---
Select from OFF-delay, ON-delay, or one-shot timer.
Timer function
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms
increments, and 1 to 5 s set in 1 s-increments)
Automatic pow-
er control (APC)
High-speed control method for emission current
Func-
tions
Zero-reset
Initial reset
Negative values can be displayed. (Threshold value is shifted.)
Settings can be returned to defaults as required.
Mutual interfer-
ence prevention
Possible for up to 9
Possible for up to 10 Units *6
Units (18 channels) *7
Switchable between
up counter and down
Counter
counter.
---
Set count:
0 to 9,999,999
*1. Input Specifications
Contact input (relay or switch)
Non-contact input (transistor)
ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc.
ON: 1.5 V max. (sourcing current: 1 mA max.)
NPN
PNP
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)
ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V.
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)
*2. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
and the Mobile Console will not function.
*3. PNP output is as follows: Operate: 53 µs, reset: 55 µs.
*4. When counter is enabled: 80 µs for operate and reset respectively.
*5. When differential output is selected for the output setting, the second channel output is 200 µs for operation and reset respectively.
*6. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
*7. Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled.
6
E3X-DA-S/MDA
Advanced models
Type
2-channel models
External input
models
Twin-output mod- ATC function mod-
Analog output
models
els
els
Item
Model
E3X-DA@RM-S
E3X-DA@TW-S
E3X-DA@AT-S
E3X-DA@AN-S
E3X-MDA@
External input set-
ting (Select from
teaching, power tun-
ing, zero reset, light
OFF, or counter re-
set.)
Output setting (Se-
lect from channel 2
output, area output,
self-diagnosis out-
put, or ATC error
output)
Output setting
Output setting
(Select from channel
2 output, area out-
put, or self-diagno-
sis.)
(Select from channel
2 output, AND, OR,
leading edge sync,
falling edge sync, or
differential output)
Analog output set-
ting (offset voltage
adjustable)
Func-
tions
I/O setting
Operation indicator
for channel 1 (or-
ange), Operation in-
dicator for channel 2
(orange)
Operation indicator
(orange), Power
Operation indicator
Operation indicator for channel 1 (orange), (orange),
Display
Tuning indicator (or- Operation indicator for channel 2 (orange) Power Tuning indi-
ange)
cator (orange)
Select from incident
level for channel 1 +
incident level for
channel 2 or other 7
patterns
Select from incident
level + threshold or Select from incident level + threshold or other 6 patterns
other 7 patterns
Digital display
Display orientation
Switching between normal/reversed display is possible.
Incandescent lamp: 10,000 lux max.
Ambient illumination
(Receiver side)
Sunlight:
20,000 lux max.
Operating: Groups of 1 to 2 Amplifiers: −25°C to 55°C
Groups of 3 to 10 Amplifiers: −25°C to 50°C
Groups of 11 to 16 Amplifiers: −25°C to 45°C
Ambient temperature range
Storage: −30°C to 70°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 MΩ min. (at 500 VDC)
Ambient humidity range
Insulation resistance
Dielectric strength
1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
Shock resistance
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
IEC 60529 IP50 (with Protective Cover attached)
Pre-wired or amplifier unit connector
Degree of protection
Connection method
Weight (packed state)
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Case
Materials
Cover
Polycarbonate (PC)
Accessories
Instruction manual
Amplifier Unit Connectors
Mobile Console
Item
Model
E3X-CN11/21/22
E3X-CN12
Item
Model
E3X-MC11-SV2
Rated current
Rated voltage
2.5 A
50 V
E3X-DA-S
Applicable
Sensors
E3X-MDA
E3C-LDA
E2C-EDA
20 mΩ max. (20 mVDC max., 100 mA max.)
Contact resistance (The figure is for connection to the Amplifier Unit and the adjacent Connec-
Power supply
voltage
Charged with AC adapter
tor. It does not include the conductor resistance of the cable.)
Destruction: 50 times
Connection
method
Connected via adapter
Approx. 580 g (Console
No. of insertions
(The figure for the number of insertions is for connection to the Amplifier Unit
and the adjacent Connector.)
Weight
(packed state) only: 120 g)
Housing
Mate-
Polybutylene terephthalate (PBT)
Phosphor bronze/gold-plated nickel
rials
Contacts
Refer to Instruction Manual provided with
the Mobile Console for details.
Weight
(packed state)
Approx. 55 g
Approx. 25 g
7
E3X-DA-S/MDA
Sensing Distance
Through-beam Models
(Unit: mm)
Model
E3X-DA@-S
E3X-MDA@
High-
reso-
lution
mode
Super- High-
Super-
high-
speed
mode
Stan- High-
dard speed
mode mode
Stan- High-
dard speed
mode mode
high-
reso-
Type
speed lution
mode mode
E32-T11R/E32-T12R/E32-T15XR/
E32-TC200BR(B4R)
700
270
530
210
130
50
350
130
75
140
50
450
170
100
35
350
130
75
230
85
140
50
Flexible
(new
standard)
E32-T14LR/E32-T15YR/E32-T15ZR
E32-T21R/E32-T22R/E32-T222R/
E32-T25XR/E32-TC200FR(F4R)
160
30
50
30
E32-T24R/E32-T25YR/E32-T25ZR
60
25
10
27
18
10
E32-TC200/E32-T12/E32-T15X/
E32-TC200B(B4)
1,000
760
500
200
650
500
330
200
E32-T14L/E32-T15Y/E32-T15Z
E32-TC200A
600
900
460
680
300
450
120
180
390
580
300
450
200
300
120
180
Standard
models
Standard
E32-TC200E/E32-T22/E32-T222/
E32-T25X/E32-TC200F(F4)
270
220
125
50
170
130
85
50
E32-T24/E32-T25Y/E32-T25Z
E32-T11/E32-T12B/E32-T15XB
E32-T21/E32-T221B/E32-T22B
E32-T25XB
160
900
240
180
130
680
200
150
75
450
110
85
30
180
45
100
580
150
125
70
450
110
95
45
300
70
30
180
45
Break-
resistant
35
60
35
Fluorine
coating
E32-T11U
900
680
450
180
580
450
300
180
E32-T17L
20,000*1 20,000*1 10,000 4,000 13,000 10,000 6,500 4,000
4,000*2 4,000*2 2,600 1,500 4,000 3,700 2,400 1,500
E32-TC200 + E39-F1
E32-T11R + E39-F1
E32-T11 + E39-F1
E32-T14
4,000*2
4,000*2
4,000*2
3,700 2,400
970 3,100 2,400 1,600
930 3,000 2,300 1,500
900 2,900 2,200 1,450
970
930
900
350
180
100
160
100
3,600 2,300
3,400 2,250
Long-
distance,
high power
E32-T11L/E32-T12L
E32-T11L + E39-F2
E32-T11R + E39-F2
E32-T11 + E39-F2
E32-T21L/E32-T22L
1,700 1,330
870
500
250
430
250
350 1,100
870
520
260
430
260
580
340
170
280
170
910
520
820
540
800
400
660
440
180
100
160
100
600
330
530
340
E32-T223R
E32-T33-S5
E32-T333-S5
E32-T334-S5
160
53
12
6
130
44
10
5
75
25
6
30
10
4
110
35
8
85
28
6
55
18
5
30
10
4
Ultracom-
pact,
ultrafine
sleeve
Special-
beam
models
3
2
4
3
2
2
E32-T22S
E32-T24S
2,500 1,900 1,250
500 1,600 1,250
830
580
500
350
Fine beam
1,750 1,300
1,100 840
1,500 1,100
980 750
870
350 1,100
870
E32-T16PR
E32-T16P
E32-T16JR
E32-T16J
E32-T16WR
E32-T16W
E32-T16
560
750
480
650
850
220
300
190
260
730
970
600
800
560
750
480
650
860
370
500
320
430
570
730
220
300
190
260
340
450
740
140
1,300 1,000
1,700 1,300
Area sensing
340 1,100
2,300 1,800 1,150
3,700 2,800 1,850
450 1,400 1,100
740 2,400 1,800 1,200
140 470 360 240
E32-M21
750
610
350
*1. The optical fiber for the E32-T17L is 10 m long on each side, so the value is 20,000 mm
*2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
8
E3X-DA-S/MDA
Model
E3X-DA@-S
E3X-MDA@
High-
reso-
lution
mode
Super- High-
Super-
high-
speed
mode
Stan- High-
dard speed
mode mode
Stan- High-
dard speed
mode mode
high-
reso-
Type
speed lution
mode mode
E32-T51
1,000
300
760
230
280
450
500
150
180
300
200
60
650
190
230
390
500
150
180
300
330
100
120
200
200
60
E32-T54
E32-T81R-S
E32-T61-S + E39-F2
E32-T61-S + E39-F1
E32-T84S-S
E32-T61-S
360
70
70
Heat-
resistant
600
120
120
900
350
120
520
800
100
350
190
50
4,000 3,400 2,200
900 3,000 2,200 1,450
1,750 1,300
600 450
870
300
350 1,100
120 390
870
300
570
200
850
Environ-
ment
E32-T11F
2,500 2,000 1,300
4,000* 3,000 2,000
520 1,600 1,300
E32-T12F
800 2,600 2,000 1,300
resistant
models
Chemical
resistant
E32-T14F
500
400
250
900
460
130
680
100
330
320
100
320
250
920
460
130
650
85
160
600
300
85
E32-T51F
1,800 1,400
350 1,190
E32-T81F-S
E32-T51V
920
260
700
200
190
50
600
170
850
110
420
410
E32-T51V + E39-F1V
E32-T54V
1,350 1,000
260
35
430
55
260
35
Vacuum
resistant
210
660
630
130
500
480
E32-T54V + E39-F1V
E32-T84SV
180
130
320
310
210
200
180
130
* The optical fiber for the E32-T12F is 2 m long on each side, so the sensing distance is 4,000 mm.
Reflective Models
(Unit: mm)
Model
E3X-DA@-S
E3X-MDA@
High-
reso-
lution
mode
Super- High-
Super-
Stan- High-
dard speed
mode mode
Stan- High-
dard speed
mode mode
high-
reso-
high-
speed
mode
Type
speed lution
mode mode
E32-D11R/E32-D12R/E32-D15XR/
E32-DC200BR(B4R)
300
170
120
50
170
120
80
50
E32-D14LR
80
70
45
40
30
26
14
12
45
40
33
29
22
19
14
12
Flexible
(new stan-
dard)
E32-D15YR/E32-D15ZR
E32-D211R/E32-D21R/E32-D22R/
E32-D25XR/E32-DC200FR(F4R)
50
30
20
8
30
22
14
8
E32-D24R
26
14
15
8
10
5
4
2
15
8
10
5
6
4
2
E32-D25YR/E32-D25ZR
3.3
E32-DC200/E32-D15X/
E32-DC200B(B4)
500
300
200
90
300
210
130
90
E32-D12
400
200
170
230
110
100
160
80
70
36
30
230
110
100
160
80
100
50
70
36
30
Standard
models
E32-D14L
Standard
E32-D15Y/E32-D15Z
65
70
45
E32-D211/E32-DC200E/E32-D22/
E32-D25X/E32-DC200F(F4)
130
80
50
22
80
55
35
22
E32-D24
50
35
30
20
20
12
8
6
30
20
22
14
14
9
8
6
E32-D25Y/E32-D25Z
E32-D11/E32-D15XB
E32-D21B/E32-D221B
E32-D21/E32-D22B
E32-D25XB
300
110
50
170
70
120
45
50
20
8
170
70
125
50
80
30
14
23
50
20
8
Break-
resistant
30
20
30
22
85
50
30
15
50
35
15
Fluorine
coating
E32-D11U
300
170
120
50
170
125
80
50
9
E3X-DA-S/MDA
Model
E3X-DA@-S
E3X-MDA@
High-
reso-
lution
mode
Super- High-
Super-
high-
speed
mode
Stan- High-
dard speed
mode mode
Stan- High-
dard speed
mode mode
high-
reso-
Type
speed lution
mode mode
40 to
1,000
40 to
700
40 to
450
40 to
240
40 to
600
40 to
490
40 to
300
40 to
240
E32-D16
Long
distance,
high power
E32-D11L
650
210
25
400
260
110
400
270
180
110
35
4
E32-D21L/E32-D22L
E32-D33
130
16
3
80
10
2
35
4
130
16
3
85
10
2
55
6
Ultracom-
pact,ultrafine
sleeve
E32-D331
5
0.8
1.3
0.8
E32-CC200R
E32-CC200
250
500
250
120
150
300
150
75
100
200
100
50
45
90
45
22
150
300
150
75
105
210
100
50
65
140
65
45
90
45
22
E32-D32L
E32-C31/E32-D32
30
Special-
beam
models
Spot diameter variable in the range 0.1 to 0.6 mm at distances in the
range 6 to 15 mm.
E32-C42 + E39-F3A
E32-D32 + E39-F3A
Coaxial/small
spot
Spot diameter variable in the range 0.5 to 1mm at distances in the range
6 to 15 mm.
E32-C41 + E39-F3A-5
E32-C31 + E39-F3A-5
E32-C41 + E39-F3B
E32-C31 + E39-F3B
E32-C31 + E39-F3C
0.1-mm dia. spot at a distance of 7 mm.
0.5-mm dia. spot at a distance of 7 mm.
0.2-mm dia. spot at a distance of 17 mm.
0.5-mm dia. spot at a distance of 17 mm.
Spot diameter of 4 mm max. at distances in the range 0 to 20 mm.
Area sensing E32-D36P1
250
150
100
45
150
100
65
45
E32-R21 + E39-R3 (provided)
10 to 250
Retroireflec-
tive
E32-R16 + E39-R1 (provided)
150 to 1,500
E32-L25/E32-L25A
E32-L24S
3.3
0 to 4
Convergent-
reflective
E32-L24L
2 to 6 (center 4)
5.4 to 9 (center 7.2)
4 to 10
E32-L25L
E32-L86
E32-D51
400
150
230
90
160
60
72
230
165
63
110
40
72
27
Heat-
resistant
E32-D81R-S
E32-D61-S
27
90
Environ-
ment-
E32-D73-S
100
160
60
95
40
65
18
30
60
95
40
70
25
45
18
30
resistant
models
E32-D12F
Chemical-
resistant
E32-D14F
70
40
30
10
40
28
18
10
10
E3X-DA-S/MDA
Application-specific Models
Type
(Unit: mm)
Model
E3X-DA@-S
E3X-MDA@
High-
reso-
lution
mode
Super- High-
Super-
high-
speed
mode
Stan- High-
dard speed
mode mode
Stan- High-
dard speed
mode mode
high-
reso-
speed lution
mode mode
E32-G14
10
Label
detection
E32-T14
4,000* 3,400 2,250
900 2,900 2,200 1,450
900
Applicable tube: Transparent tube with a diameter in the range 8 to 10
mm and a recommended wall thickness of 1 mm
E32-L25T
E32-D36T
E32-A01
Applicable tube: Transparent tube (no restriction on diameter)
Liquid-level
detection
Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm
and a recommended wall thickness of 1 mm
Applicable tube: Transparent tube with a diameter in the range 6 to 13
mm and a recommended wall thickness of 1 mm
E32-A02
E32-D82F1(F2)
E32-L16-N
E32-A08
Liquid-contact model
Applica-
tion-
specific
models
0 to 15
10 to 20
15 to 25
0 to 12
---
0 to 15
10 to 20
15 to 25
0 to 12
---
Glass-
substrate
alignment
E32-A07E1(E2)
E32-L66
---
---
5 to 18
5 to 16
---
5 to 18
5 to 14
---
E32-A09/E32-A09H
E32-A09H2
15 to 38
---
15 to 38
20 to 30
---
---
Glass-
substrate
Mapping
20 to 30
890
---
E32-A03/E32-A03-1
E32-T24S
1,150
600
870
225
250
750
580
870
220
380
580
145
250
350
100
Wafer
mapping
1,750 1,300
460 340
350 1,100
100 300
E32-A04/E32-A04-1
* The optical fiber for the E32-T14 is 2 m long on each side, so the sensing distance is 4,000 mm.
11
E3X-DA-S/MDA
Green, Blue, and Infrared Light Sources
Type
(Unit: mm)
Model
E3X-DAG@-S/DAB@-S
E3X-DAH@-S
High-
Super- High-
Super-
high-
speed
mode
Stan- High-
dard speed
mode mode
Stan- High-
dard speed
mode mode
reso-
lution
mode
high-
speed lution
mode mode
reso-
E32-T11R/E32-T12R/E32-T15XR/
E32-TC200BR(B4R)
65
25
50
20
75
35
22
50
30
12
45
280
100
400
190
75
130
80
55
21
80
E32-T14LR/E32-T15YR/E32-T15ZR
Through-
beam
Standard
E32-TC200/E32-T12/E32-T15X/
E32-TC200B(B4)
100
280
180
models
E32-T14L/E32-T15Y/E32-T15Z
50
40
30
85
25
75
240
700
160
490
110
320
45
Special beam E32-T11L/E32-T12L
E32-D11R/E32-D12R/E32-D15XR/
150
120
140
17
14
10
8
120
90
60
21
E32-DC200BR(B4R)
E32-D14LR
4.4
4.2
3.5
3.3
2.5
2.2
2.2
2.1
32
28
24
20
16
13
5.5
5
E32-D15YR/E32-D15ZR
Standard
E32-DC200/E32-D15X/
E32-DC200B(B4)
32
25
16
16
200
150
100
35
Reflective
models
E32-D14L
11
10
44
15
32
15
7.5
9
8
6
5.5
22
8
5.5
5
80
65
60
50
40
33
14
11
45
17
35
17
8.5
E32-D15Y/E32-D15Z
E32-D11L
35
12
25
12
6
22
7.5
16
7.5
3.5
260
100
200
100
50
190
75
130
50
E32-CC200R
Special beam E32-CC200
E32-D32L
16
8
150
75
100
50
E32-C31/E32-D32
4
37
25
Applica-
tion-
specific
models
E32-T14
E32-G14
320
260
220
160 1,800 1,200
10
820
360
Label
detection
10
Refer to E32 Series for details on Fiber Units.
12
E3X-DA-S/MDA
Output Circuit Diagrams
NPN Output
Operation
Operation
selector
Model
mode
Timing charts
Output circuit
Incident light
No incident light
Operation
ON
OFF
indicator
(orange)
Operation indicator
(orange)
LIGHT ON
(L-ON)
Display
Power
Light-ON
Dark-ON
ON
OFF
E3X-DA11-S
E3X-DA6-S
Brown
Black
Output
transistor
Load
Load
(relay)
tuning
indicator
(orange)
Operate
Reset
(Between brown and black leads)
E3X-DAG11-S
E3X-DAG6-S
E3X-DAB11-S
E3X-DAB6-S
E3X-DA11SE-S
E3X-DA6SE-S
Photo-
Control output
electric
Sensor
main
12 to
24 VDC
Incident light
No incident light
circuit
Operation
indicator
(orange)
ON
OFF
ON
OFF
Operate
Reset
Blue
DARK ON
(D-ON)
Output
transistor
Load
(relay)
(Between brown and black leads)
CH1/ Incident light
CH2 No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
indicator
(orange)
Operation indicator
(orange)
ch 1
Operation indicator
(orange) ch 2
LIGHT ON
(L-ON)
Display
Light-ON
Dark-ON
Brown
Black
Output
transistor
E3X-DA11TW-S
E3X-DA6TW-S
E3X-MDA11
Load
Load
(relay)
Control
Photo-
Load
output 1
electric
Sensor
main
(Between brown and black leads)
Orange
12 to
E3X-MDA6
Control
output 2
24 VDC
CH1/ Incident light
CH2 No incident light
circuit
E3X-DA11AT-S
E3X-DA6AT-S
Operation
indicator
(orange)
Output
transistor
ON
OFF
ON
Blue
DARK ON
(D-ON)
OFF
Operate
Reset
Load
(relay)
(Between brown and black leads)
Incident light
No incident light
Operation indicator
(orange)
Operation
indicator
(orange)
ON
OFF
ON
Brown
Black
Display
Power
LIGHT ON
(L-ON)
Light-ON
Dark-ON
Output
transistor
Load
OFF
tuning
indicator
(orange)
Operate
Load
Photo-
Control output
E3X-DA11RM-S
E3X-DA6RM-S
(relay)
Reset
electric
Sensor
main
12 to
24 VDC
(Between brown and black leads)
Orange
External
input
Operation
indicator
(orange)
ON
OFF
ON
circuit
Blue
DARK ON
(D-ON)
Output
transistor
OFF
Operate
Load
Reset
(relay)
(Between brown and black leads)
Incident light
No incident light
Operation
indicator
(orange)
ON
OFF
LIGHT ON
(L-ON)
Operation indicator
(orange)
Light-ON
Dark-ON
ON
Brown
Black
Display
Output
transistor
Load
OFF
Power
tuning
indicator
(orange)
Load
Operate
Reset
(relay)
12 to
Photo-
(Between brown and black leads)
Control output
Analog
24 VDC
electric
Sensor
main
E3X-DA11AN-S
Orange
Incident light
output
models
10kΩmin
No incident light
circuit
Load
Operation
indicator
(orange)
ON
OFF
Blue
DARK ON
(D-ON)
ON
Output
transistor
Load
OFF
Operate
Reset
(relay)
(Between brown and black leads)
Note: 1. The ON/OFF regions when areas settings are used with the E3X-
3. Control Output (AND, OR, Sync) and Timing Chart for Timer Settings
(T: Set Time)
DA@TW-S are as follows:
LIGHT ON: ON when the incident level is between the thresholds for
channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for
channels 1 and 2.
2. Timing Charts for Timer Function Settings (T: Set Time)
ON
OFF
ON
ON
OFF
ON
CH1
CH2
CH1
CH2
OFF
ON
OFF
ON
T
OUT
(AND)
ON delay
(AND)
ON delay
OFF delay
One-shot
OFF
ON
OFF
ON
T
OUT
(OR)
OFF delay
(AND)
Incident light
Incident light
Incident light
OFF
ON
OFF
ON
No incident light
No incident light
No incident light
T
T
T
T
T
OUT
(sync)
One-shot
(AND)
ON
ON
ON
L-ON
L-ON
L-ON
OFF
OFF
OFF
OFF
OFF
T
T
T
ON
ON
ON
D-ON
D-ON
D-ON
OFF
OFF
OFF
13
E3X-DA-S/MDA
PNP Output
Model
Opera-
tion mode
Operation
selector
Timing chart
Output circuit
Incident light
No incident light
Operation
ON
OFF
indicator
(orange)
Output
LIGHT ON
(L-ON)
Operation indicator
(orange)
Light-ON
Dark-ON
Light-ON
Dark-ON
Display
Power
ON
E3X-DA41-S
E3X-DA8-S
Brown
transistor
OFF
Load
(relay)
tuning
indicator
(orange)
Operate
Reset
Control
output
E3X-DAG41-S
E3X-DAG8-S
E3X-DAB41-S
E3X-DAB8-S
E3X-DA41SE-S
E3X-DA8SE-S
Photo-
electric
Sensor
main
(Between blue and black leads)
Black
Blue
12 to
24 VDC
Incident light
circuit
Load
No incident light
Operation
indicator
(orange)
Output
ON
OFF
DARK ON
(D-ON)
ON
transistor
OFF
Load
(relay)
Operate
Reset
(Between blue and black leads)
Incident light
CH1/
CH2
No incident light
Operation
indicator
(orange)
Output
ON
OFF
LIGHT ON
(L-ON)
Operation indicator
(orange)
ch 1
Operation indicator
(orange) ch 2
ON
Display
transistor
OFF
Brown
E3X-DA41TW-S
E3X-DA8TW-S
E3X-MDA41
E3X-MDA8
E3X-DA41AT-S
E3X-DA8AT-S
Load
(relay)
Operate
Reset
Control
output 1
Black
Control
output 2
Orange
Photo-
(Between blue and black leads)
electric
Sensor
main
12 to
24 VDC
Incident light
CH1/
CH2
circuit
Load
No incident light
Operation
indicator
(orange)
Output
Load
ON
OFF
DARK ON
(D-ON)
Blue
ON
transistor
OFF
Load
(relay)
Operate
Reset
(Between blue and black leads)
Incident light
No incident light
Operation
ON
OFF
indicator
(orange)
Output
LIGHT ON
(L-ON)
Operation indicator
(orange)
Light-ON
ON
Display
Power
Brown
transistor
OFF
External
input
Load
(relay)
Operate
tuning
indicator
(orange)
Orange
Black
Blue
Reset
Photo-
(Between blue and black leads)
E3X-DA41RM-S
E3X-DA8RM-S
Control
output
electric
Sensor
main
12 to
24 VDC
Incident light
circuit
No incident light
Operation
Load
ON
OFF
indicator
(orange)
Output
DARK ON
(D-ON)
Dark-ON
Light-ON
Dark-ON
ON
transistor
OFF
Load
(relay)
Operate
Reset
(Between blue and black leads)
Incident light
No incident light
Operation
indicator
(orange)
Output
ON
OFF
LIGHT ON
(L-ON)
Operation indicator (orange)
ON
Display
Brown
transistor
OFF
Power
tuning
indicator
(orange)
Load
(relay)
Operate
Analog
Orange output models
Reset
Photo-
electric
Sensor
main
12 to
24 VDC
(Between blue and black leads)
Control
E3X-DA41AN-S
output
Black
Incident light
circuit
No incident light
Operation
Load Load
10kΩmin
ON
OFF
Blue
indicator
(orange)
Output
DARK ON
(D-ON)
ON
transistor
OFF
Load
(relay)
Operate
Reset
(Between blue and black leads)
Note: The ON/OFF regions when areas settings are used with the E3X-DA@TW-S are as follows:
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
14
E3X-DA-S/MDA
Nomenclature
Amplifier Units
E3X-DA@-S
E3X-DA@RM-S
E3X-DA@AN-S
Main Display (Red)
E3X-DA@TW-S
E3X-DA@AT-S
E3X-MDA@
Sub-Display (Green)
Threshold, function settings,
Operation Keys
Function setting operations
UP
Sub-Display (Green)
Threshold, function settings,
etc.
Operation Keys
Function setting operations
Main Display (Red)
Incident level, function, etc.
Lock lever
Incident level, function, etc. etc.
UP
Lock lever
Locks the fiber.
DOWN
MODE
DOWN
MODE
Locks the fiber.
Operation Selector
Use to switch between Light
ON and Dark ON modes.
Operation Indicator
(orange)
ON when output is
ON.
OFF when output is
OFF.
Channel Selector
Use to switch between channels
1 and 2.
Operation indicator for
channel 1 (orange)
ON when output is ON.
Operation indicator for
channel 2 (orange)
ON when output is ON.
Mode Selector
Use to select SET or RUN mode.
Mode Selector
Use to select SET or RUN mode.
Power Tuning Indicator
ON: Power tuning is set.
OFF when output is OFF. OFF when output is OFF.
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is to be
removed away from the rest of the group.
2. After the Amplifier Unit(s) has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
Press down
Lever
Amplifier Unit
● Designing
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power supply is
turned ON. If the Sensor and load are connected to separate power
supplies, be sure to turn ON the Sensor first.
Remove
Adding and Removing Amplifier Units
Adding Amplifier Units
● Mounting
1. Mount the Amplifier Units one at a time onto the DIN track.
Connecting and Disconnecting Connectors
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
Insert
2. Attach the protector seals (provided as accessories) to the sides of
master and slave connectors that are not connected.
Click into place
Removing Amplifier Units
Seal
Note: Attach the seals to the sides with grooves.
Seal
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
Note: 1. The specifications for ambient temperature will vary according to the
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
2. Always turn OFF the power supply before joining or separating
Amplifier Units.
15
E3X-DA-S/MDA
Mounting the End Plate (PFP-M)
Fibers That Cannot Be Free-Cut (with Sleeves)
An End Plate should be used if there is a possibility of the Amplifier
Unit moving, e.g., due to vibration. If a Mobile Console is going to be
mounted, connect the End Plate in the direction shown in the following
diagram.
9 mm
13 mm
2. Disconnecting Fibers
Remove the protective cover and raise the lock lever to pull out the
fibers.
End Plate
Mounting the Mobile Console Head
Leave a gap of at least 20 mm between the nearest Amplifier Unit and
the Mobile Console head.
Protective cover
20 mm
Unlocked
Locked
Note: 1. To maintain the fiber properties, confirm that the lock is released
before removing the fibers.
Fiber Connection
2. Be sure to lock or unlock the lock button within an ambient
temperature range between −10°C and 40°C.
The E3X Amplifier Unit has a lock button for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following
procedures:
● Adjusting
Mutual Interference Protection Function
1. Connection
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
lever.
There may be some instability in the digital display values due to light
from other sensors. If this occurs, decrease the sensitivity (i.e.,
decrease the power or increase the threshold) to perform stable
detection.
EEPROM Writing Error
Lock button
If the data is not written to the EEPROM correctly due to a power
failure or static-electric noise, initialize the settings with the keys on
the Amplifier Unit. ERR/EEP will flash on the display when a writing
error has occurred.
Protective cover
Unlocked
Locked
Insertion position
Optical Communications
Fiber insertion mark
Fiber
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of the
Amplifier Units during operation.
9 mm
● Others
Protective Cover
Fibers with E39-F9 Attachment
Always keep the protective cover in place when using the Amplifier
Unit.
Mobile Console
Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S-series
Amplifier Units.
Fiber Unit
9 mm
13 mm
16
E3X-DA-S/MDA
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Amplifier Units
Amplifier Units with Cables
E3X-DA11-S
E3X-DA41-S
Operation indicator
Main display
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
E3X-DAG11-S
E3X-DAG41-S
E3X-DAB11-S
E3X-DAB41-S
E3X-DA11RM-S
E3X-DA41RM-S
E3X-DA11TW-S
E3X-DA41TW-S
E3X-DA11SE-S
E3X-DA41SE-S
E3X-DA11AT-S
E3X-DA41AT-S
E3X-DA11AN-S
E3X-DA41AN-S
E3X-MDA11
Vinyl-insulated round cable
Standard length: 2 m*
Sub-display
CH2
CH1
(E3X-DA@-S)
(E3X-MDA@)
*Cable Specifications
E3X-DA11-S
-DA41-S
4-dia., 3-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter: 1.1 mm)
-DAG11-S
-DAG41-S
-DAB11-S
-DAB41-S
E3X-MDA41
E3X-DA11TW-S
-DA41TW-S
-DA11RM-S
-DA41RM-S
4-dia., 4-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter, 1.1 mm)
4-dia., 2-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter: 1.1 mm)
E3X-MDA11
-MDA41
With Mounting Bracket Attached
3.9 × 3 = 11.7
32.8
29.8
3.9 × 3
* The Mounting Bracket can also
be used on this side.
15.1
12.15
A *
=11.7
3.25
4.3
10
10
70
Two, 2.4 dia.
4.5
7
32
Four, 2.4 dia.
9.9
3.4
12.5
4.5
4.5
5.65
5.65
28.1
16
Hole for optical communications
(E3X-DA@-S)
(E3X-MDA@)
18.7
34.8
44.3
Two, 3.2 dia. holes
Mounting Bracket (E39-L143)
SUS304 stainless steel
3.4
4.4
Two, M3
16
Mounting Holes
28.1
16
17
E3X-DA-S/MDA
Amplifier Units with Connectors
E3X-DA6-S
E3X-DA8-S
E3X-DAG6-S
E3X-DAG8-S
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
Operation indicator
Main display
Sub-display
E3X-DAB6-S
E3X-DAB8-S
E3X-DA6RM-S
E3X-DA8RM-S
E3X-DA6TW-S
E3X-DA8TW-S
E3X-DA6SE-S
E3X-DA8SE-S
E3X-DA6AT-S
E3X-DA8AT-S
CH2
CH1
(E3X-DA@-S)
(E3X-MDA@)
E3X-MDA6
E3X-MDA8
*1 The Mounting Bracket can also be
used on this side.
With Mounting Bracket Attached
*2 Cable Diameters
3.9 × 3 = 11.7
E3X-CN22
32.8
(2 conductors)
E3X-CN21
(4 conductors)
E3X-CN11
29.8
3.9 × 3
4.0-mm
dia.
A *1
15.1
12.15
=11.75
3.25
(3 conductors)
E3X-CN12
(1 conductor)
2.6-mm
dia.
70
10
10
4.3
8.1
Connector
Two, 2.4 dia.
Four, 2.4 dia.
4.5
7
Dia. A*2
32
9.9
3.4
4.5
4.5
12.95
5.65
5.65
(E3X-DA@-S)
(E3X-MDA@)
28.1
18.7
16
Hole for optical communications
34.8
44.3
Mounting Bracket (E39-L143)
SUS304 stainless steel
Two, 3.2-dia. holes
3.4
4.4
16
Two, M3
16
Mounting Holes
28.1
18
E3X-DA-S/MDA
Amplifier Unit Connectors
2,000+50
Master Connectors
10
0
6
10.7
6.8
E3X-CN11
E3X-CN21
2.9
2.6
4
4 dia.
*
14.4
0.8
8.4
15.1
6
30±2
10±2
50+5
0
*E3X-CN11: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave Connectors
E3X-CN12
E3X-CN22
10
6
2,000+50
0
10.7
6.8
2.9
E3X-CN12: 2.6 dia.
E3X-CN22: 4 dia.
4
2.6
*
14.4
2
2
10±
8.4
15.1
30±
6
0.8
50+5
3
0
*E3X-CN12: 2.6-dia. vinyl-insulated round cable with 1 conductor (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
19
E3X-DA-S/MDA
Mobile Console
E3X-MC11-SV2
Mobile Console
Mobile Console Head
AC adapter jack
Communications jack
Menu indicators
Optical communications connection indicator
Communications jack
22
52.8
10
20
Channel indicator
(38.2)
31.8
13.2
13.1
16.3
5.1
1.2
28.8
12.3
Sensor
operation
indicator
Main display
Sub-display
17.3
24.3
27.7
Channel
buttons
30.3
9.9
5.6
136
Optical communica-
UP key
tions position
RIGHT key
31.2
M5 ball plunger
36.7
51.3
LEFT key
ESC/PWR key
DOWN
key
ENT key
Operation keys
Battery
indicators
50
Refer to E32 Series for details on Fiber Units.
20
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
·
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.
相关型号:
E3X-DA41AT-S
Evolution and Perfection The next-generation platform for a wide range of sensing
OMRON
E3X-DA41SE-S
Evolution and Perfection The next-generation platform for a wide range of sensing
OMRON
©2020 ICPDF网 联系我们和版权申明