Manual Fiber Amplifier  
E3X-NA  
CSM_E3X-NA_DS_E_2_2  
Simple and Easy-to-Use Amplifiers  
with a Sensitivity Adjuster  
Provided as a Standard Feature  
Intuitive LED bar display shows light levels at a glance.  
Utilizes OMRON’s innovative wire-saving connector.  
Reduced wiring and space requirements for power  
lines.  
Optical communications prevents mutual interference  
for up to 5 amplifiers  
High-speed detection, mark-detecting, and water-  
resistant models also available.  
Be sure to read Safety Precautions on  
page 10.  
Ordering Information  
Amplifier Units  
Amplifier Units with Cables (2m)  
Model  
Item  
Standard models  
Appearance  
Control output  
NPN output  
E3X-NA11 2M  
PNP output  
E3X-NA41 2M  
E3X-NA51 2M  
E3X-NA41F 2M  
E3X-NAG41 2M  
With self-diagnosis function  
High-speed detection models  
Mark-detecting models  
E3X-NA21 2M  
E3X-NA11F 2M  
E3X-NAG11 2M  
ON/OFF output  
Water-resistant models  
E3X-NA11V 2M  
E3X-NA41V 2M  
Amplifier Units with Connectors  
Model  
Applicable Connector  
(order separately)  
Item  
Appearance  
Control output  
NPN output  
PNP output  
Master  
Slave  
E3X-CN11  
E3X-CN12  
Standard models  
E3X-NA6  
E3X-NA8  
ON/OFF output  
Water-resistant  
models  
(M8 connectors)  
XS3F-M421-40@-A  
XS3F-M422-40@-A  
E3X-NA14V  
E3X-NA44V  
Model  
Amplifier Unit Connectors (Order Separately) Note: Stickers for Connectors are included as accessories.  
No. of  
Item  
Appearance  
Cable length  
conductors  
Master Connector  
3
1
E3X-CN11  
E3X-CN12  
2 m  
Slave Connector  
1
E3X-NA  
Combining Amplifier Units and Connectors  
Refer to the following tables when placing an order.  
Amplifier Units  
NPN  
Applicable Connectors (Order Separately)  
Type  
Standard  
models  
PNP  
+
+
Master Connector  
Slave Connector  
E3X-NA6  
E3X-NA8  
E3X-CN11 (3-wire)  
E3X-CN12 (1-wire)  
Basically, Amplifier Units and Connectors are sold  
separately.  
When Using 5 Amplifier Units  
5 Amplifier Units  
1 Master Connector + 4 Slave Connectors  
Sensor I/O Connectors (Order Separately)  
Size  
Cable specifications  
Appearance  
Cable type  
2 m  
Model  
XS3F-M421-402-A  
Straight connector  
Four-  
conductor  
cable  
5 m  
2 m  
5 m  
XS3F-M421-405-A  
XS3F-M422-402-A  
XS3F-M422-405-A  
M8  
Standard cable  
L-shaped connector  
Note: Refer to Introduction to Sensor I/O Connectors for details.  
Accessories (Order Separately)  
Mounting Brackets  
End Plate  
Appearance  
Applicable models  
Model  
E39-L143  
Quantity  
Appearance  
Model  
PFP-M  
Quantity  
E3X-NA@  
E3X-NA@F  
E3X-NAG@  
1
1
E3X-NA@V  
E39-L148  
2
E3X-NA  
Ratings and Specifications  
Amplifier Units  
High-speed  
Type  
Standard models  
Mark-detecting models  
E3X-NAG@  
Water-resistant models  
E3X-NA@V  
detection models  
NPN  
output  
Model  
E3X-NA@  
E3X-NA@F  
PNP  
output  
Item  
Light source  
(wavelength)  
Red LED (680 nm)  
Green LED (520 nm)  
Red LED (680 nm)  
Power supply  
voltage  
12 to 24 VDC ”10%, ripple (p-p): 10% max.  
Current  
consumption  
35 mA max.  
(for 24-VDC power supply)  
35 mA max.  
35 mA max.  
Control output  
Load current: 50 mA max.; residual voltage: 1 V max.; NPN/PNP (depends on model) open collector; Light-ON/Dark-ON mode selector  
Self-diagnosis  
output  
None  
Yes  
None  
Operate: 20 Ps max.  
Reset: 30 Ps max.  
Response time  
Operate or reset: 200 Ps max. *1  
Operate or reset: 200 Ps max. *1  
Sensitivity  
adjustment  
8-turn sensitivity adjuster (with indicator)  
Protection circuits  
Timer function  
Reverse polarity, output short-circuit, mutual interference prevention (optically synchronized) *2  
OFF-delay timer: 40 ms (fixed)  
Ambient illumination Incandescent lamp: 10,000 lux max.  
(Receiver side)  
Sunlight:  
20,000 lux max.  
Operating:Groups of 1 to 3 Amplifiers: 25“C to 55“C  
Groups of 4 to11 Amplifiers: 25“C to 50“C  
Ambient  
temperature range  
Groups of 12 to16 Amplifiers: 25“C to 45“C  
Storage: 30“C to 70“C (with no icing or condensation)  
Ambient humidity  
range  
Operating and storage: 35% to 85% (with no condensation)  
Insulation resistance 20 M: min. (at 500 VDC)  
Dielectric strength  
1,000 VAC at 50/60 Hz for 1 minute *3  
Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions  
Shock resistance  
Destruction: 500 m/s2, for 3 times each in X, Y and Z directions  
IEC 60529 IP66 (with Pro-  
tective Cover attached)  
Degree of protection IEC 60529 IP50 (with Protective Cover attached)  
Connection method Pre-wired (standard cable length: 2 m) or connector  
Weight  
Pre-wired models: approx. 100 g, Connector models: approx. 55 g (See note 4.) *4  
Polybutylene terephthalate (PBT)  
(packed state)  
Case  
Material  
Cover Polycarbonate  
Polyethersulfone (PES)  
Accessories  
Instruction manual  
*1. When there are 8 or more Units mounted side-by-side, the response time will be 350 Ps max.  
*2. High-speed detection models do not have the mutual interference prevention function.  
*3. The dielectric strength for water-resistant models with M8 connectors is 500 VAC.  
*4. Add 10 g to the weight for water-resistant models.  
Amplifier Unit Connectors  
Item  
Model  
E3X-CN11  
E3X-CN12  
Rated current  
Rated voltage  
2.5 A  
50 V  
20 m: max. (20 mVDC max., 100 mA max.)  
Contact resistance  
(The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.)  
Number of inser-  
tions  
Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector)  
Housing  
Material  
Polybutylene terephthalate (PBT)  
Phosphor bronze/gold-plated nickel  
Contact  
Weight  
(packed state)  
Approx. 55 g  
Approx. 25 g  
3
E3X-NA  
Sensing Distance  
Through-beam Models  
(Unit: mm)  
Model  
E3X-NA@  
E3X-NA@F  
General-purpose  
models  
High-speed  
models  
Type  
E32-T11R/E32-T12R/E32-T15XR/E32-TC200BR(B4R)  
E32-T14LR/E32-T15YR/E32-T15ZR  
E32-T21R/E32-T22R/E32-T222R/E32-T25XR/  
E32-TC200FR(F4R)  
280  
110  
80  
33  
Flexible  
(new standard)  
60  
18  
E32-T24R/E32-T25YR/E32-T25ZR  
E32-TC200/E32-T12/E32-T15X/E32-TC200B(B4)  
E32-T14L/E32-T15Y/E32-T15Z  
E32-TC200A  
E32-TC200E/E32-T22/E32-T222/E32-T25X/E32-TC200F(F4)  
E32-T24/E32-T25Y/E32-T25Z  
30  
400  
240  
360  
100  
90  
9
120  
70  
100  
30  
Standard  
models  
Standard  
27  
E32-T11/E32-T12B/E32-T15XB  
Break resistant E32-T21/E32-T221B/E32-T22B  
E32-T25XB  
360  
100  
75  
100  
30  
20  
Fluorine coating E32-T11U  
E32-T17L  
360  
14000  
3000  
2100  
2000  
1800  
700  
500  
220  
360  
200  
60  
100  
4200  
900  
630  
600  
540  
210  
150  
65  
E32-TC200 + E39-F1  
E32-T11R + E39-F1  
E32-T11 + E39-F1  
E32-T14  
Long distance,  
high power  
E32-T11L/E32-T12L  
E32-T11L + E39-F2  
E32-T11R + E39-F2  
E32-T11 + E39-F2  
E32-T21L/E32-T22L  
E32-T223R  
100  
60  
18  
E32-T33-S5  
E32-T333-S5  
E32-T334-S5  
E32-T22S  
E32-T24S  
E32-T16PR  
E32-T16P  
E32-T16JR  
E32-T16J  
E32-T16WR  
E32-T16W  
E32-T16  
20  
5
2.5  
6
Special-beam  
models  
Ultracompact,  
ultrafine sleeve  
1.5  
0.8  
300  
210  
130  
180  
110  
150  
200  
270  
450  
90  
120  
35  
50  
130  
900  
210  
90  
380  
480  
60  
1000  
700  
450  
600  
390  
520  
690  
920  
1500  
300  
400  
130  
180  
390  
3000  
700  
300  
1050  
1600  
200  
700  
350  
100  
600  
65  
Fine beam (nar-  
row vision field)  
Area sensing  
E32-M21  
E32-T51  
E32-T54  
E32-T81R-S  
Heat resistant E32-T61-S + E39-F2  
E32-T61-S + E39-F1  
E32-T84S-S  
E32-T61-S  
E32-T11F  
Environment-  
resistive  
E32-T12F  
Chemical  
E32-T14F  
resistant  
models  
E32-T51F  
200  
100  
---  
E32-T81F-S  
E32-T51V  
E32-T51V + E39-F1V  
---  
---  
---  
---  
Vacuum  
E32-T54V  
resistant  
E32-T54V + E39-F1V  
E32-T84SV  
390  
250  
4
E3X-NA  
Reflective Models  
Type  
(Unit: mm)  
Model  
E3X-NA@  
General-purpose  
models  
E3X-NA@F  
High-speed  
models  
E32-D11R/E32-D12R/E32-D15XR/E32-DC200BR(B4R)  
E32-D14LR  
90  
30  
5
16  
20  
E32-D15YR/E32-D15ZR  
5
Flexible  
(new standard)  
E32-D211R/E32-D21R/E32-D22R/E32-D25XR/  
E32-DC200FR(F4R)  
15  
5
E32-D24R  
7
4
2.3  
1.2  
50  
40  
13  
15  
E32-D25YR/E32-D25ZR  
E32-DC200/E32-D15X/E32-DC200B(B4)  
E32-D12  
150  
120  
40  
E32-D14L  
Standard  
models  
E32-D15Y/E32-D15Z  
50  
Standard  
E32-D211/E32-DC200E/E32-D22/E32-D25X/  
E32-DC200F(F4)  
36  
12  
E32-D24  
15  
10  
5
3.3  
30  
E32-D25Y/E32-D25Z  
E32-D11/E32-D15XB  
E32-D21B/E32-D221B  
E32-D21/E32-D22B  
E32-D25XB  
90  
35  
10  
Break resistant  
15  
5
25  
8
Fluorine coating E32-D11U  
E32-D16  
90  
30  
40 to 400  
200  
50  
55 to 70  
65  
Long distance,  
E32-D11L  
high power  
E32-D21L/E32-D22L  
17  
E32-D33  
10  
3.3  
0.5  
25  
Ultracompact,  
ultrafine sleeve  
E32-D331  
1.5  
E32-CC200R  
75  
E32-CC200  
150  
80  
50  
E32-D32L  
25  
E32-C31/E32-D32  
E32-C42 + E39-F3A  
E32-D32 + E39-F3A  
E32-C41 + E39-F3A-5  
E32-C31 + E39-F3A-5  
E32-C41 + E39-F3B  
E32-C31 + E39-F3B  
E32-C31 + E39-F3C  
40  
13  
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.  
Spot diameter of 0.5 to 1mm at 6 to 15 mm.  
Spot diameter of 0.1 mm at 7 mm  
Coaxial,  
small spot  
Special-beam  
models  
Spot diameter of 0.5 mm at 7 mm.  
Spot diameter of 0.2 mm at 17 mm.  
Spot diameter of 0.5 mm at 17 mm.  
Spot diameter of 4 mm max. at 0 to 20 mm.  
Area sensing E32-D36P1  
75  
25  
E32-R21 + E39-R3 (provided)  
10 to 250  
Retro-reflective  
E32-R16 + E39-R1 (provided)  
E32-L25/E32-L25A  
E32-L24S  
150 to 1500  
150 to 1000  
3.3  
0 to 4  
E32-L24L  
2 to 6 (center 4)  
Convergent-  
reflective  
E32-L25L  
5.4 to 9 (center 7.2)  
E32-L86  
4 to 10  
E32-L16  
0 to 15  
120  
45  
0 to 13  
40  
E32-D51  
Heat resistant E32-D81R/E32-D61  
E32-D73  
15  
Environment-  
30  
10  
resistive models  
E32-D12F  
E32-D14F  
50  
16  
Chemical  
resistant  
20  
6.5  
5
E3X-NA  
Application-specific Models  
(Unit: mm)  
Model  
E3X-NA@  
E3X-NA@F  
General-purpose  
models  
High-speed  
models  
Type  
E32-G14  
E32-T14  
10  
Label detection  
1800  
540  
Applicable tube: Transparent tube with a  
diameter in the range 8 to 10 mm and a  
recommended wall thickness of 1 mm  
Application-  
specific Models  
E32-L25T  
Liquid-level  
detection  
Applicable tube: Transparent tube  
(no diameter restrictions )  
E32-D36T  
E32-D82F1(F2)  
Liquid-contact model  
Green Light Source Models  
Type  
(Unit: mm)  
Model  
E3X-NAG@  
Mark-detecting Models  
E32-T11R/E32-T12R/E32-T15XR/E32-TC200BR(B4R)  
E32-T14LR/E32-T15YR/E32-T15ZR  
50  
20  
75  
45  
130  
15  
3.5  
3.3  
25  
10  
8
Standard  
Through-beam  
models  
E32-TC200/E32-T12/E32-T15X/E32-TC200B(B4)  
E32-T14L/E32-T15Y/E32-T15Z  
Special beam E32-T11L/E32-T12L  
E32-D11R/E32-D12R/E32-D15XR/E32-DC200BR(B4R)  
E32-D14LR  
E32-D15YR/E32-D15ZR  
E32-DC200/E32-D15X/E32-DC200B(B4)  
E32-D14L  
Standard  
Reflective  
E32-D15Y/E32-D15Z  
E32-D11L  
35  
12  
25  
12  
6
E32-CC200R  
Special beam E32-CC200  
E32-D32L  
E32-C31/E32-D32  
E32-T14  
E32-G14  
330  
10  
Application  
specific  
Label detection  
Refer to E32 Series for details on Fiber Units.  
6
E3X-NA  
Engineering Data (Typical)  
Number of Turns of Sensitivity Adjuster vs. Sensing Distance  
E32-T11L  
E32-D11L  
1.2  
400  
1.0  
300  
200  
100  
0.8  
0.6  
0.4  
0.2  
E3X-NA@(V)  
E3X-NA@(V)  
E3X-NA@F  
E3X-NA@F  
2
4
6
8
10  
2
4
6
8
10  
0
0
Number of turns  
Number of turns  
Sensing Distance vs. Differential Travel  
E32-T11L  
E32-D11L  
100  
20  
80  
60  
15  
10  
5
E3X-NA@(V)  
E3X-NA@(V)  
40  
20  
100  
200  
300  
400  
500  
600 700  
0
50  
100  
150  
200  
0
Distance (mm)  
Distance (mm)  
7
E3X-NA  
I/O Circuit Diagrams  
NPN Output  
Operation  
Operation  
selector  
Model  
mode  
Timing charts  
Output circuit  
Incident light  
No incident light  
T
Operation  
indicator  
(orange)  
Brown  
ON  
OFF  
1
Operation indicator  
(orange)  
LIGHT ON  
(L-ON)  
Light-ON  
ON  
Load  
Output  
Photo-  
electric  
Sensor  
main  
transistor  
OFF  
Black  
12 to  
24 VDC  
4
E3X-NA11  
E3X-NA6  
Operate  
Load  
(relay)  
Control output  
circuit  
Reset  
(Between brown and black leads)  
E3X-NAG11  
E3X-NA11F  
E3X-NA11V  
E3X-NA14V  
Blue  
3
Incident light  
No incident light  
T
Operation  
indicator  
(orange)  
ON  
OFF  
DARK ON  
(D-ON)  
M8 Connector Pin Arrangement  
Note: Pin 2 is not used.  
Dark-ON  
2
4
ON  
Output  
transistor  
1
3
OFF  
Operate  
Reset  
Load  
(relay)  
(Between brown and black leads)  
Incident light  
No incident light  
T
Operation  
ON  
OFF  
indicator  
(orange)  
LIGHT ON  
(L-ON)  
Light-ON  
Brown  
Operation indicator  
(orange)  
ON  
Output  
transistor  
12 to  
24 VDC  
OFF  
Load  
Operate  
Reset  
(relay)  
Load  
(relay)  
Photo-  
electric  
Sensor  
main  
Control  
output  
Black  
(Between brown and black leads)  
Load  
(relay)  
E3X-NA21  
Orange  
circuit  
Incident light  
Self-diagnosis output  
0 V  
No incident light  
T
Operation  
indicator  
(orange)  
ON  
OFF  
Incident level  
indicators  
(4 green, 1 red)  
Blue  
DARK ON  
(D-ON)  
Dark-ON  
ON  
Output  
transistor  
OFF  
Operate  
Reset  
Load  
(relay)  
(Between brown and black leads)  
8
E3X-NA  
PNP Output  
Model  
Operation  
mode  
Operation  
selector  
Timing charts  
Output circuit  
Incident light  
Brown  
Operation  
indicator  
(orange)  
No incident light  
1
4
3
T
Operation  
indicator  
(orange)  
Output  
ON  
OFF  
Control  
output  
Photo-  
LIGHT ON  
(L-ON)  
Black  
Blue  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
electric  
Sensor  
main  
ON  
12 to  
24 VDC  
transistor  
OFF  
circuit  
Load  
Operate  
E3X-NA41  
E3X-NA8  
E3X-NAG41  
E3X-NA41F  
E3X-NA41V  
E3X-NA44V  
Load  
(relay)  
Reset  
(Between blue and black leads)  
Incident light  
No incident light  
T
Operation  
indicator  
(orange)  
M8 Connector Pin Arrangement  
Note: Pin 2 is not used.  
ON  
OFF  
2
4
3
1
DARK ON  
(D-ON)  
ON  
Output  
transistor  
OFF  
Operate  
Reset  
(Between blue and black leads)  
Load  
(relay)  
Incident light  
No incident light  
T
Operation  
ON  
OFF  
indicator  
(orange)  
LIGHT ON  
(L-ON)  
Brown  
Operation indicator  
ON  
12 to  
24 VDC  
Output  
transistor  
(orange)  
OFF  
Operate  
Reset  
(Between blue and black leads)  
Load  
(relay)  
Orange  
Self-diagnosis output  
Photo-  
electric  
Sensor  
main  
E3X-NA51  
Control  
output  
Load  
(relay)  
circuit  
Black  
Blue  
Incident light  
No incident light  
Load  
(relay)  
T
Operation  
ON  
OFF  
indicator  
(orange)  
Incident level  
indicators  
(4 green, 1 red)  
DARK ON  
(D-ON)  
0 V  
ON  
Output  
transistor  
OFF  
Operate  
Reset  
Load  
(relay)  
(Between blue and black leads)  
Plug (Sensor I/O Connector)  
Terminal number  
Classification  
Wire color  
Brown  
White  
Connectionpin Application  
Wire color  
Power supply  
2
1
2
3
4
Brown  
White  
Blue  
4
1
(+V)  
1
3
Black  
2
3
4
---  
DC  
Power supply  
(0 V)  
Blue  
XS3F-M421-402-A  
XS3F-M421-405-A  
XS3F-M422-402-A  
XS3F-M422-405-A  
Black  
Output  
Note: Pin 2 is not used.  
Nomenclature  
Amplifier Units  
Sensitivity indicator  
8-turn sensitivity adjuster  
Operation Selector  
Use to switch between  
Light-ON and Dark-ON  
Incident level indicators  
Lock lever  
Operation Indicator  
Timer switch  
ON: Timer function is ON.  
OFF: Timer function is OFF.  
9
E3X-NA  
Safety Precautions  
Refer to Warranty and Limitations of Liability.  
WARNING  
This product is not designed or rated for ensuring  
safety of persons either directly or indirectly.  
Do not use it for such purposes.  
Fiber Connection and Disconnection  
The E3X Amplifier Unit has a lock lever. Connect or disconnect the  
fibers to or from the E3X Amplifier Unit using the following  
procedures:  
1. Connection  
Precautions for Correct Use  
Do not use the product in atmospheres or environments that exceed  
product ratings.  
Open the Protective Cover, insert the fibers according to the fiber  
insertion marks on the side of the Amplifier Unit, and lower the lock  
lever.  
Amplifier Units  
Designing  
Insertion position  
Lock button  
Communications Hole  
The hole on the side of the Amplifier Unit is a communications hole for  
preventing mutual interference when Amplifier Units are mounted  
side-by-side. The E3X-MC11 Mobile Console (order separately)  
cannot be used.  
Fiber insertion mark  
10.7 mm  
Fiber  
If an excessive amount of light is received via the Sensor, the mutual  
interference prevention function may not work. In this case, make the  
appropriate adjustments using the sensitivity adjuster.  
The mutual interference prevention function will not operate when the  
E3X-NA is used side-by-side with E3X-DA-N models.  
2. Disconnection  
Remove the Protective Cover and raise the lock lever to pull out the  
fiber.  
Mounting  
Protective cover  
DIN Track Mounting/Removal  
Unlocked  
Locked  
Mounting Amplifier Units  
1. Mount the Amplifier Units one at a time onto the DIN track.  
Note:To maintain the fiber properties, confirm that the lock is released  
before removing the fiber.  
3. Precautions for Fiber Connection/Disconnection  
Be sure to lock or unlock the lock lever within an ambient temperature  
range between 10“C and 40“C.  
2. Slide the Amplifier Units together, line up the clips, and press the  
Amplifier Units together until they click into place.  
Operating Environment  
Ambient Conditions  
If dust or dirt adhere to the hole for optical communications, it may  
prevent normal communications. Be sure to remove any dust or dirt  
before using the Units.  
Clip  
Click into  
place  
Removing Amplifier Units  
Slide Amplifier Units away from each other, and remove from the DIN  
track one at a time. (Do not attempt to remove Amplifier Units from the  
DIN track without separating them first.)  
Other  
Protective Cover  
Be sure to mount the Protective Cover before use.  
Note: 1. The specifications for ambient temperature will vary according to the  
number of Amplifier Units used together. For details, refer to Ratings  
and Specifications.  
2. Always turn OFF the power supply before mounting or removing  
Amplifier Units.  
10  
E3X-NA  
Amplifier Units with Connectors  
Mounting  
Mounting End Plate (PFP-M)  
Depending on how it is mounted, an Amplifier Unit may move during  
operation. In this case, use an End Plate.  
Before mounting an End Plate, remove the clip from the master  
Amplifier Unit using a nipper or similar tool.  
Mounting Connectors  
1. Insert the Master or Slave Connector into the Amplifier Unit until it  
clicks into place.  
Insert  
Clip  
2. Join Amplifier Units together as required after all the Master and  
Slave Connectors have been inserted.  
3. Attach the seals (provided as accessories) to the sides of Master  
and Slave Connectors that are not connected to other Connectors.  
The clip can also be removed using the following mechanism, which  
is incorporated in the construction of the section underneath the clip.  
1. Insert the clip to be removed into the slit underneath the clip on  
another Amplifier Unit.  
Sticker  
Sticker  
Note: Attach the stickers to the sides with grooves.  
Removing Connectors  
1. Slide the slave Amplifier Unit for which the Connector is to be  
removed away from the rest of the group.  
2. After the Amplifier Unit has been separated, press down on the  
lever on the Connector and remove it. (Do not attempt to remove  
Connectors without separating them from other Amplifier Units  
first.)  
2. Remove the clip by rotating the Amplifier Unit.  
Press down  
Lever  
Rotate  
Remove  
Pull Strengths for Connectors (Including Cables)  
E3X-CN11: 30 N max.  
E3X-CN12: 12 N max.  
11  
E3X-NA  
Dimensions  
(Unit: mm)  
Amplifier Units  
Amplifier Units with Cables  
E3X-NA11  
E3X-NA11F  
E3X-NA41  
E3X-NA41F  
E3X-NAG11  
E3X-NAG41  
E3X-NA21  
With Mounting Bracket Attached  
4-dia. vinyl-insulated round cable with 3  
conductors (Conductor cross section: 0.2  
mm2; Insulator diameter: 1.1 mm),  
Standard length: 2 m.  
Incident level indicators  
A (See note 1.)  
Operation indicator  
* The EX3-NA21 and E3X-NA51 use  
4-conductor cable.  
13.05  
15.75  
9.2  
E3X-NA51  
3
64.3  
10  
38.6  
5.3  
Two, 2.4 dia.  
Mounting Holes  
Two, M3  
31.5  
4.1  
8
9.9  
10.7  
16  
10.75  
Hole for optical communications (See note 2.)  
22.4  
13  
16  
2.4  
4
34.8  
Two, 3.2-dia. holes  
Mounting bracket (E39-L143) (Order separately)  
Stainless steel (SUS304)  
22.4  
16  
4.4  
3.4  
Note: 1. The mounting bracket can also be  
used on side A.  
2. The hole for optical  
communications is for preventing  
mutual interference. There is no  
hole for E3X-NA@F models.  
4.4  
3.4  
Amplifier Units with Cables, Water-resistant Models  
E3X-NA11V  
E3X-NA41V  
With Mounting Bracket Attached  
28.65  
25.95  
9.2  
(See note 2.)  
Operation indicator  
A (See note 1.)  
Incident level indicators  
81.5  
12  
6.9  
40  
Two, 2.4 dia.  
2.8  
33  
8
9.9  
11.2  
10.7  
Hole for  
optical  
communi-  
cations  
23.9  
14.4  
16  
37  
67.2  
3.9 3.4  
4.3  
11.5  
6.6  
Mounting Holes  
16  
23.9  
Mounting bracket (E39-L148) (Order separately)  
Stainless steel (SUS304)  
5.4  
3.4  
Two, M3  
16  
5.4  
3.4  
Note: 1. The mounting bracket can also be used on  
side A.  
2. 4-dia. vinyl-insulated round cable with 3  
conductors (Conductor cross section: 0.45  
mm2, Insulator diameter: 1.1 mm),  
Standard length: 2 m.  
12  
E3X-NA  
Amplifier Units with Connectors  
E3X-NA6  
E3X-NA8  
Incident level indicators  
Operation indicator  
13.05  
15.75  
9.2  
10  
3
64.3  
Two, 2.4 dia.  
31.5  
8
14  
9.9  
10.7  
5.5  
3.4  
1.8  
38.6  
13  
36.7  
Hole for optical communications  
(for preventing mutual interference)  
5.1 3.9  
1.8  
1.7  
4.2  
6.2  
1.7  
Dimensions with Master Connector Connected  
Dimensions with Slave Connector Connected  
71  
67.5  
71  
67.5  
64.3  
64.3  
E3X-CN12:  
2.6 dia.  
E3X-CN11:  
4.0 dia.  
31.5  
1.5  
31.5  
1.5  
17.45  
12.95  
12.95  
11.55  
3
4
4
1.8  
1.8  
5.1 3.9  
5.1 3.9  
4.8  
10  
10  
13  
E3X-NA  
With Mounting Bracket Attached  
28.65  
9.2  
Amplifier Units with Connectors, Water-resistant  
Models  
* The mounting bracket can also be  
25.95  
E3X-NA14V  
used on this side.  
E3X-NA44V  
Operation indicator  
*
Incident level indicators  
81.5  
12  
6.9  
40  
Two, 2.4 dia.  
M8  
2.8  
33  
8
9.9  
11.2  
10.7  
Hole for  
optical  
communi-  
cations  
23.9  
14.4  
16  
37  
67.2  
3.9 3.4  
4.3  
11.5  
11  
Mounting Holes  
16  
23.9  
Mounting bracket (E39-L148) (Order separately)  
Stainless steel (SUS304)  
Two, M3  
3.4  
5.4  
16  
5.4  
3.4  
Amplifier Unit Connectors  
Sensor I/O Connectors  
Accessories (Order Separately)  
Mounting Brackets  
End Plates  
Refer to E32 Series for details on Fiber Units.  
14  

相关型号:

E3X-NAG412M

Manual Fiber Amplifier
OMRON

E3X-NH

Fine Tuning Fiber Photoelectric Sensor
OMRON

E3X-NH11

Fine Tuning Fiber Photoelectric Sensor
OMRON

E3X-NH21

Fine Tuning Fiber Photoelectric Sensor
OMRON

E3X-NH41

Fine Tuning Fiber Photoelectric Sensor
OMRON

E3X-NH51

Fine Tuning Fiber Photoelectric Sensor
OMRON

E3X-NHB

暂无描述
OMRON

E3X-NHB11

Fine Tuning Fiber Photoelectric Sensor
OMRON

E3X-NL

Optical Fiber Glossy Object Sensor
OMRON

E3X-NL11

Optical Fiber Glossy Object Sensor
OMRON

E3X-NM

Fiber-Optic Accessories
ETC

E3X-NM11

Teaching Optical Fiber Photoelectric Sensor
OMRON