Programmable Digital Controller  
E5AR-T  
CSM_E5AR-T_DS_E_2_1  
A new High-speed, High-precision Digital  
Controller that is Programmable!  
• Create up to 32 programs with up to 256 segments total.  
• Coordinated operation for up to four channels with one Digital  
Controller.  
• 0.01°C High resolution for Pt input.  
• High-speed sampling at 50 ms.  
• Settings easily made from a computer using the CX-Thermo.  
• RoHS compliance for world-wide application.  
Refer to Safety Precautions for All E5@R  
Models.  
Model Number Structure  
Model Number Legend  
E5AR-T@@@@@@@@-@@@  
1 2 3 4 5 6 7 8  
9
1. Control method  
Blank:Standard or heating/cooling control  
P: Position proportional control  
2. Output 1  
5. Communications  
Blank:None  
3:  
RS-485 communications  
6. Optional function  
Blank:None  
R:  
Q:  
C:  
NO relay output + NO relay output  
Pulse output/current output + pulse output  
Current output + current output  
D:  
4 event inputs  
M:  
4 event inputs + 4 event inputs  
3. Output 2  
7. Input 1  
R:  
Q:  
C:  
NO relay output + NO relay output  
Pulse output/current output + pulse output  
Current output + current output  
B:  
F:  
W:  
Universal-input and 2 event inputs  
Universal-input and FB  
Universal-input and universal-input  
4. Auxiliary Outputs  
8. Input 2  
Blank:None  
Blank:None  
4:  
E:  
NO relay output + NO relay output  
5 transistor outputs + 5 transistor outputs  
W:  
9. Other  
Universal-input and universal-input  
FLK: CompoWay/F communications  
Note: The above model number legend is intended as a functional description of models. Not all possible combinations of functions are available.  
Confirm model availability in Ordering Information when ordering.  
Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital  
Controller.  
E5AR/ER Digital Controller User's Manual (Cat. No. Z182)  
1
E5AR-T  
Ordering Information  
Digital Controllers  
Programmable Digital Controllers  
Size Control type  
Control mode  
Outputs  
Optional functions  
Auxiliary Event Serial  
outputs inputs communi-  
(SUB) cations  
None E5AR-TQ4B  
Model  
(control/transfer)  
96 × 96 Basic control Standard control  
mm (1 loop) Heating and cooling control  
2 (pulse + pulse/cur- 4  
rent)  
2
2 (current + current)  
E5AR-TC4B  
2 (pulse + pulse/cur-  
rent)  
RS-485  
E5AR-TQ43B-FLK  
(See note 2.)  
2 (current + current)  
E5AR-TC43B-FLK  
(See note 2.)  
2 (pulse + pulse/cur- 10 (See 10  
E5AR-TQE3MB-FLK  
(See note 2.)  
rent)  
note 3.)  
2 (current + current)  
E5AR-TCE3MB-FLK  
(See note 2.)  
4 (pulse + pulse/cur-  
rent + 2 current)  
E5AR-TQCE3MB-FLK  
2-loop control 2-loop standard control  
2 (pulse + pulse/cur- 4  
4
RS-485  
RS-485  
E5AR-TQ43DW-FLK  
(See note 2.)  
Single-loop heating and cooling control rent)  
Single-loop cascade control  
Single-loop control with remote SP  
Single-loop proportional control  
2 (current + current)  
E5AR-TC43DW-FLK  
(See note 2.)  
4 (2 pulse + pulse/2 10 (See  
8
8
E5AR-TQQE3MW-  
FLK  
current)  
note 3.)  
4-loop control 4-loop standard control  
4 (4 current)  
10 (See  
note 3.)  
E5AR-TCCE3MWW-  
FLK  
2-loop heating and cooling control  
(See note 4.)  
4 (2 pulse + pulse/2  
current)  
E5AR-TQQE3MWW-  
FLK (See note 2.)  
Control valve Single-loop position-proportional control Relay outputs  
4
4
8
None  
E5AR-TPR4DF  
control  
(1 open, 1 closed)  
(1 loop)  
Relay outputs  
(1 open, 1 closed)  
and 1 current  
10 (See  
note 3.)  
RS-485  
E5AR-TPRQE3MF-  
FLK  
Note 1: Specify the power supply specifications when ordering. Model numbers for 100 to 240 VAC are different from those for 24 VAC/VDC.  
2: These models are for 100 to 240 VAC only.  
3: The outputs are transistor output.  
4: Only for coordinated operation. (A separate program cannot be set for each channel.)  
Inspection Results  
If an inspection report is required, it can be ordered at the same time  
as the Digital Controller using the following model number.  
Accessories (Order Separately)  
Terminal Cover  
Descriptions  
Model  
E53-COV14  
Inspection Report (Order Separately)  
Terminal Cover for E5AR  
Model  
E5AR-K  
Unit Label Sheet  
Model  
Y92S-L1  
Rubber Packing  
Model  
Y92S-P4  
Note: The Rubber Packing is provided with the Digital Controller.  
2
E5AR-T  
Specifications  
Ratings  
Supply voltage  
(See note 2.)  
CE marking  
UL certification  
100 to 240 VAC, 50/60 Hz  
100 to 120 VAC, 50/60 Hz  
24 VAC, 50/60 Hz; 24 VDC  
Operating voltage range  
Power consumption  
85% to 110% of rated supply voltage  
22 VA max. (with maximum load)  
15 VA/10 W max. (with maximum load)  
Sensor input (See note 3.)  
Thermocouple: K, J, T, E, L, U, N, R, S, B, W  
Platinum resistance thermometer: Pt100  
Current input: 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input)  
Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input)  
(Input impedance: 150 for current input, approx. 1 Mfor voltage input)  
Control output Voltage (pulse) output 12 VDC, 40 mA max. with short-circuit protection circuit (E5AR-TQQE3MW-FLK: 21 mA max.)  
Current output  
0 to 20 mA DC, 4 to 20 mA DC; load: 500 max. (including transfer output)  
(Resolution: Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC)  
Relay output  
Position-proportional control type (open, closed)  
N.O., 250 VAC, 1 A (including inrush current)  
Auxiliary output  
Relay Output  
N.O., 250 VAC, 1 A (resistive load)  
Transistor Output  
Maximum load voltage: 30 VDC; Maximum load current: 50 mA; Residual voltage: 1.5 V max.; Leakage cur-  
rent: 0.4 mA max.  
Potentiometer input  
100 to 2.5 kΩ  
Event input  
Contact  
No-contact  
Input ON: 1 kmax.; OFF: 100 kmin.  
Input ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 mA max.  
Short-circuit: Approx. 4 mA  
Remote SP input  
Transfer output  
Control method  
Setting method  
Refer to the information on sensor input.  
Refer to the information on control output.  
2-PID or ON/OFF control  
Digital setting using front panel keys or setting using serial communications  
Indication method  
7-segment digital display and single-lighting indicator  
Character Height  
PV display: 12.8 mm; SV display: 7.7 mm; MV display: 7.7 mm  
Other functions  
Depends on model.  
Ambient operating temperature  
10 to 55°C (with no icing or condensation)  
For 3 years of assured use: 10 to 50°C (with no icing or condensation)  
Ambient operating humidity  
Storage temperature  
25% to 85%  
25 to 65°C (with no icing or condensation)  
Note 1: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All E5@R Models.)  
2: The supply voltage (i.e., 100 to 240 VAC or 24 VAC/VDC) depends on the model. Be sure to specify the required type when ordering.  
3: The Controller is equipped with multiple sensor input. Temperature input or analog input can be selected with the input type setting switch. There is basic  
insulation between power supply and input terminals, power supply and output terminals, and input and output terminals.  
Input Ranges  
Platinum Resistance Thermometer, Thermocouple, Current, or Voltage Input  
Platinum  
resistance  
thermometer  
Input type  
Thermocouple  
Current  
Voltage  
Pt100  
K
J
T
E
L
U
N
R
S
B
W
mA  
V
Name  
W/Re  
5-26  
(
)
2300.0  
2300  
1800  
1300  
900  
800  
700  
600  
400  
200  
100  
0
1700.0 1700.0 1800.0  
1300.0  
1300.0  
850.0  
850.0  
850.0  
Tempera-  
ture  
20 to 20 to  
10 to  
0
500.0  
600.0  
5 to 1 5 to 0  
400.0  
400.0  
400.0  
range  
(°C)  
4
0
150.00  
100.0  
0.0  
7
0.0  
11  
0.0  
12  
0.0  
14  
100  
200  
20.0 100.0 20.0  
100.0  
200.0 150.00 200.0  
200.0  
200.0 200.0  
Setting  
0
1
2
3
4
5
6
8
9
10  
13  
15  
16  
17  
18  
19  
Minimum  
(Depends on scaling and number  
of decimal places.)  
0.01  
°C  
setting unit  
0.1°C  
0.1°C  
(SP and alarm)  
TC.PT  
TC.PT  
Input type  
setting switch  
IN1  
IN1  
Set to ANALOG  
TYPE  
Set to TC.PT.  
TYPE  
ANALOG  
ANALOG  
Note: The shaded area indicates the setting status at the time of purchase.  
3
E5AR-T  
Characteristics  
Indication accuracy  
Thermocouple input with cold junction compensation: ( 0.1% of PV or 1°C, whichever is greater) 1 digit max. (See note 1.)  
Thermocouple input without cold junction compensation: ( 0.1% FS or 1°C, whichever is smaller) 1 digit (See note 2.)  
Analog input: 0.1% FS 1 digit max.  
Platinum resistance thermometer input: ( 0.1% of PV or 0.5°C, whichever is greater) 1 digit max.  
Position-proportional potentiometer input: 5% FS 1 digit max.  
Control mode  
Standard control (heating or cooling control), heating/cooling control, standard control with remote SP (2-input models only), heating/cool-  
ing control with remote SP (2-input models only), cascade standard control (2-input models only), cascade heating/cooling control (2-input  
models only), proportional control (2-input models only), position-proportional control (control-valve control models only)  
Influence of temperature Thermocouple input (R, S, B, W): ( 1% of PV or 10ꢀC, whichever is greater) 1 digit max.  
Other thermocouple input: ( 1% of PV or 4ꢀC, whichever is greater) 1 digit max.  
Influence of voltage  
*K thermocouple at -100ꢀC max.: 10ꢀC max.  
Platinum resistance thermometer: ( 1% of PV or 2ꢀC, whichever is greater) 1 digit max.  
Analog input: ( 1%FS) 1 digit max.  
Control period  
0.2 to 99.0 s (in units of 0.1 s) for time-proportioning control output  
0.00% to 999.99% FS (in units of 0.01% FS)  
0.0 to 3,999.9 s (in units of 0.1 s)  
Proportional band (P)  
Integral time (I)  
Derivative time (D)  
Hysteresis  
0.0 to 3,999.9 s (in units of 0.1 s)  
0.01% to 99.99% FS (in units of 0.01% FS)  
0.0% to 100.0% (in units of 0.1% FS)  
Manual reset value  
Alarm setting range  
19,999 to 99,999 EU (See note 3.)  
(The decimal point position depends on the input type and the decimal point position setting.)  
Input sampling period  
Insulation resistance  
Dielectric strength  
50 ms  
20 Mmin. (at 500 VDC)  
2,000 VAC, 50/60 Hz for 1 min (between charged terminals of different polarities)  
10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions  
Vibration resistance  
(malfunction)  
100 m/s2, 3 times each in X, Y, and Z directions  
Shock resistance  
(malfunction)  
Inrush current  
100 to 240-VAC models: 50 A max.  
24 VAC/VDC models: 30 A max.  
Weight  
Controller only: Approx. 450 g; Mounting bracket: Approx. 60 g; Terminal cover: Approx. 30 g  
Front panel: NEMA4X for indoor use; Rear case: IP20; Terminals: IP00  
Non-volatile memory (number of writes: 100,000)  
Degree of protection  
Memory protection  
Applicable standards  
UL 61010C-1, CSA C22.2 No. 1010-1  
(Power supply voltage: 100 to 120 VAC): Pollution degree 2/Overvoltage category 2  
EN 61010-1 (IEC 61010-1) (Power supply voltage: 100 to 240 VAC): Pollution degree 2/Overvoltage category 2  
EMC  
EMI: EN61326  
Radiated Interference Electromagnetic Field Strength: EN55011 Group 1 Class A  
Noise Terminal Voltage: EN55011 Group 1 Class A  
EMS: EN61326  
ESD Immunity: EN61000-4-2:  
4 kV contact discharge (level 2)  
8 kV air discharge (level 3)  
Electromagnetic Immunity: EN61000-4-3:  
Burst Noise Immunity:  
10 V/m (amplitude-modulated, 80 MHz to 1 GHz, 1.4 GHz to 2 GHz) (level 3)  
EN61000-4-4:2 kV power line (level 3)  
2 kV output line (relay output) (level 4)  
1 kV measurement line, I/O signal line (level 4)  
1 kV communications line (level 3)  
Conducted Disturbance Immunity: EN61000-4-6:  
Surge Immunity:  
3 V (0.15 to 80 MHz) (level 3)  
EN61000-4-5:1 kV line to line (power line, output line (relay output)) (level 2)  
2 kV line to ground (power line, output line (relay output)) (level 3)  
Power Frequency Magnetic Field Immunity: EN61000-4-8: 30 A/m (50 Hz) continuous field  
Voltage Dip/Interrupting Immunity: EN61000-4-11: 0.5 cycle, 100% (rated voltage)  
Note 1: K-, T-, or N-type thermocouple at 100°C max.: 2°C 1 digit max.  
U- or L-type thermocouple: 2°C 1 digit max.  
B-type thermocouple at 400°C max.: No accuracy specification.  
R- or S-type thermocouple at 200°C max.: 3°C 1 digit max.  
W-type thermocouple: ( 0.3% of PV or 3°C, whichever is greater) 1 digit max.  
2: U- or L-type thermocouple: 1°C 1 digit  
R- or S-type thermocouple at 200°C max.: 1.5°C 1 digit  
3: “EU” (Engineering Unit) represents the unit after scaling. If a temperature sensor is used, it is either °C or °F.  
4
E5AR-T  
Communications Specifications  
Transmission path connection  
Communications method  
Synchronization method  
Baud rate  
Multiple points  
RS-485 (two-wire, half duplex)  
Start-stop synchronization  
9,600, 19,200, or 38,400 bps  
ASCII  
Transmission code  
Data bit length  
7 or 8 bits  
Stop bit length  
1 or 2 bits  
Error detection  
Vertical parity (none, even, odd)  
Block check character (BCC): CompoWay/F  
CRC-16: Modbus  
Flow control  
None  
Interface  
RS-485  
None  
Retry function  
Communications buffer  
217 bytes  
Communications response send wait time 0 to 99 ms, Default: 20 ms  
Program Control Functions  
Number of programs (patterns)  
Number of segments (steps)  
Maximum number of segments  
Segment setting method  
32 (with 8 segments/program)  
32 (with 8 programs)  
256  
Time setting (Segment set with set point and time.)  
Gradient setting (Segment set with set point, gradient, and time.)  
Segment times  
0 h 0 min to 99 h 59 min  
0 min 0 s to 99 min 59 s  
0 min 00.0 s to 99 min 59.9 s  
Alarm group num- Number of groups  
4
ber specifications  
Setting method  
Set separately for each program.  
Reset operation  
Select either stopping control or fixed SP operation.  
Startup operation  
Select continuing, resetting, manual operation, run mode, or ramp back operation.  
PID sets  
Number of sets  
Setting method  
8
Set separately for each program (automatic PID group selection also supported).  
Select from ramp SP and target SP.  
Alarm SP function  
Program status  
control  
Segment operation  
Program operation  
Wait method  
Advance, hold, and back  
Program repetitions and program links  
Select from waiting at segment ends and always waiting.  
Wait width upper limit and lower limit set separately for each program.  
ON/OFF setting for each segment  
Wait operation  
Time signals  
Wait width setting  
Setting method  
Number of outputs  
6
Number of ON/OFF  
operations  
3 each per output  
Setting method  
Set separately for each program.  
10  
Segment outputs Number of outputs  
Setting method  
ON/OFF set for each segment.  
Program status output  
Program end output (pulse width can be set)  
Segment number output  
Program startup PV start  
Select from segment 1 set point, slope-priority PV start, and time-priority PV start.  
operation  
Standby  
Standby  
Operation end operation  
Number of event inputs  
Select from resetting, continuing control at final set point, and fixed SP control.  
10 max.  
5
E5AR-T  
Wiring Terminals  
E5AR-T (Programmable Type)  
E5AR-TQ4B  
E5AR-TC4B  
100 to 240 VAC  
24 VAC/DC  
Auxiliary output  
(Relay output)  
A
B
C
D
E
Auxiliary output  
(Relay output)  
+
24 VAC/DC  
100 to 240 VAC  
A
B
C
D
E
1
2
3
4
5
6
1
2
3
4
5
6
!
+
B
1
2
3
4
5
6
1
2
3
4
5
6
!
B
+
COM  
SUB1  
1
2
3
4
5
6
+
COM  
1
2
3
4
5
6
SUB1  
SUB2  
COM  
Input power supply  
Input power supply  
depends on model.  
100 to 240 VAC or 24  
VAC/DC (no polarity)  
SUB2  
COM  
depends on model.  
100 to 240 VAC or 24  
VAC/DC (no polarity)  
SUB3  
SUB4  
SUB3  
SUB4  
F
G
H
I
J
K
F
G
H
I
J
K
Event input  
EV1  
1
1
2
3
4
5
Event input  
EV1  
OUT2  
1
2
3
4
5
1
2
3
4
5
Current output  
2
3
4
5
EV2  
+
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output  
EV2  
+
COM  
OUT2  
+
Voltage output 12 V  
40 mA  
COM  
type setting.)  
+
+
+
OUT1  
OUT1  
+
+
Current output  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output  
type setting.)  
Voltage output 12 V  
40 mA or  
Current output  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output type setting.)  
6
F
6
+
V
6
F
6
+
I
PT  
TC  
K
(Thermocouple)  
(Voltage)  
(Current)  
I
V
PT  
(Voltage)  
TC  
K
(Resistance temperature input sensor)  
(Thermocouple)  
(Current)  
(Resistance temperature input sensor)  
E5AR-TQ43B-FLK  
E5AR-TC43B-FLK  
Auxiliary output  
(Relay output)  
100 to 240 VAC  
Auxiliary output  
(Relay output)  
A
B C D E  
1
B
!
B
100 to 240 VAC  
A
B C D E  
COM  
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
COM  
1
1
2
3
4
5
6
1
2
3
4
5
6
!
SUB1  
SUB1  
2
SUB2  
COM  
SUB2  
3
COM  
4
SUB3  
SUB4  
SUB3  
5
+
SUB4  
6
B(+)  
RS-485  
A()  
1
2
3
4
5
+
OUT2  
Voltage output 12 V 40 mA  
OUT1  
+
Voltage output 12 V  
40 mA or  
6
F
Current output  
F
G
H
I
J K  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
Event input  
EV1  
+
B(+)  
RS-485  
A()  
F
G
H
I
J K  
Event input  
EV1  
1
2
3
4
5
(Switched by output type setting.)  
1
OUT2  
Current output  
EV2  
2
1
+
COM  
3
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output  
2
3
4
5
EV2  
+
4
COM  
+
+
type setting.)  
5
OUT1  
Current output  
+
6
F
6
K
+
+
4 to 20 mA DC, 500 max.  
I
V
PT  
TC  
0 to 20 mA DC, 500 max.  
(Switched by output  
type setting.)  
6
(Thermocouple)  
(Resistance temperature input sensor)  
+
V
(Current) (Voltage)  
I
PT  
TC  
K
(Thermocouple)  
(Voltage)  
(Current)  
(Resistance temperature input sensor)  
The power supply voltage must be 100 to 240 VAC or 24 VAC/DC for the E5AR-T to comply with CE  
marking requirements.  
Note  
The power supply voltage must be 100 to 120 VAC or 24 VAC/DC for the E5AR-T to comply with UL  
requirements.  
6
E5AR-T  
E5AR-TQE3MB-FLK  
E5AR-TCE3MB-FLK  
Auxiliary output  
Auxiliary output  
(Transistor output)  
(Transistor output)  
B C  
1
B C  
1
+
COM  
COM  
100 to 240 VAC  
A
B C D E  
+
+
SUB1(B), SUB6(C)  
100 to 240 VAC  
A
B
C
D
E
2
3
4
5
6
SUB1(B), SUB6(C)  
SUB2(B), SUB7(C)  
SUB3(B), SUB8(C)  
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
!
1
2
3
4
5
6
1
2
3
4
5
6
+
+
+
+
SUB2(B), SUB7(C)  
SUB3(B), SUB8(C)  
!
+
+
+
SUB4(B), SUB9(C)  
SUB5(B), SUB10(C)  
SUB4(B), SUB9(C)  
SUB5(B), SUB10(C)  
Event input  
Event input  
D E  
1
D E  
1
EV3(E),EV7(D)  
2
3
4
5
6
EV3(E), EV7(D)  
EV4(E), EV8(D)  
EV5(E), EV9(D)  
2
3
4
5
6
EV4(E),EV8(D)  
EV5(E),EV9(D)  
F
G
H
I
J K  
F
G
H
I
J K  
EV6(E),EV10(D)  
COM  
EV6(E), EV10(D)  
COM  
+
B(+)  
RS-485  
A()  
1
+
B(+)  
RS-485  
A()  
Event input  
EV1  
2
3
4
5
1
Event input  
EV1  
1
2
3
4
5
+
OUT2  
OUT2  
Current output  
1
2
3
4
5
2
3
4
5
Voltage output 12 V 40 mA  
+
EV2  
EV2  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output  
COM  
OUT1  
+
+
COM  
Voltage output 12 V  
40 mA or  
Current output  
+
+
type setting.)  
6
F
+
OUT1  
+
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output type setting.)  
Current output  
6
F
6
4 to 20 mA DC, 500 max.  
+
V
6
0 to 20 mA DC, 500 max.  
+
I
PT  
(Voltage)  
TC  
K
(Switched by output type setting.)  
I
V
PT TC  
K
(Thermocouple)  
(Current)  
(Thermocouple)  
(Voltage)  
(Current)  
(Resistance temperature input sensor)  
(Resistance temperature input sensor)  
E5AR-TQCE3MB-FLK  
Auxiliary output  
(Transistor output)  
B C  
1
-
100 to 240 VAC  
24 VAC/DC  
A
B C D E  
COM  
-
+
+
+
1
2
3
4
5
6
1
2
3
4
5
6
SUB1(B), SUB6(C)  
!
2
3
4
5
6
+
SUB2(B), SUB7(C)  
SUB3(B), SUB8(C)  
-
Input power supply  
depends on model.  
100 to 240 VAC or 24  
VAC/DC (no polarity)  
+
+
+
SUB4(B), SUB9(C)  
SUB5(B), SUB10(C)  
+
B(+)  
RS-485  
A()  
Voltage output 12 V  
40 mA  
1
2
3
4
5
Event input  
D E  
1
OUT2  
+
EV3(E), EV7(D)  
2
OUT1  
EV4(E), EV8(D)  
EV5(E), EV9(D)  
3
4
5
6
+
Voltage output 12 V  
40 mA or  
Current output  
6
F
EV6(E), EV10(D)  
COM  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output type setting.)  
F
G
H
I
J K  
Event input  
EV1  
1
OUT4  
Current output  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output  
type setting.)  
OUT3  
Current output  
1
2
3
4
5
2
3
4
EV2  
+
+
COM  
+
+
+
5
6
G
4 to 20 mA DC, 500 max.  
6
K
0 to 20 mA DC, 500 max.  
I
V
PT  
TC  
(Switched by output type setting.)  
(Thermocouple)  
(Voltage)  
(Current)  
(Resistance temperature input sensor)  
The power supply voltage must be 100 to 240 VAC or 24 VAC/DC for the E5AR-T to comply with CE  
marking requirements.  
Note  
The power supply voltage must be 100 to 120 VAC or 24 VAC/DC for the E5AR-T to comply with UL  
requirements.  
7
E5AR-T  
E5AR-TQ43DW-FLK (2-loop Control)  
E5AR-TC43DW-FLK (2-loop Control)  
Auxiliary output  
Auxiliary output  
(Relay output)  
(Relay output)  
B
B
COM  
1
2
3
4
5
6
COM  
1
2
3
4
5
6
100 to 240 VAC  
A
B C D E  
100 to 240 VAC  
A
B C D E  
SUB1  
SUB2  
COM  
SUB3  
SUB4  
SUB1  
SUB2  
COM  
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
!
!
SUB3  
SUB4  
+
+
B(+)  
RS-485  
A()  
1
2
3
4
5
B(+)  
RS-485  
A()  
1
2
3
4
5
Event input  
OUT2  
Current output  
E
1
+
Event input  
E
1
+
OUT2  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output  
+
EV3  
EV4  
EV5  
2
3
4
5
6
Voltage output 12 V 40 mA  
EV3  
EV4  
EV5  
2
3
4
5
6
OUT1  
type setting.)  
+
Voltage output 12 V  
40 mA or  
Current output  
OUT1  
Current output  
F
G
H
I
J K  
6
F
6
F
F
G
H
I
J K  
EV6  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output type setting.)  
EV6  
COM  
(Switched by output type setting.)  
COM  
+
1
2
3
4
5
+
+
1
Input 2  
Input 1  
+
2
3
4
5
+
+
+
I
Input 2  
Input 1  
PT  
PT  
TC  
V
V
+
+
I
V
PT  
PT  
TC  
6
K
+
TC  
I
6
+
+
(Thermocouple)  
(Voltage)  
(Current)  
I
V
TC  
K
(Resistance temperature input sensor)  
(Thermocouple)  
(Voltage)  
(Current)  
(Resistance temperature input sensor)  
E5AR-TQQE3MW-FLK (2-loop Control)  
Auxiliary output  
(Transistor output)  
B C  
1
24 VAC/DC  
100 to 240 VAC  
COM  
+
A
B C D E  
!
+
+
SUB1(B), SUB6(C)  
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
+
SUB2(B), SUB7(C)  
SUB3(B), SUB8(C)  
SUB4(B), SUB9(C)  
SUB5(B), SUB10(C)  
Input power supply  
depends on model.  
100 to 240 VAC or 24  
VAC/DC (no polarity)  
+
+
+
+
B(+)  
RS-485  
A()  
1
2
3
4
5
Event input  
D E  
1
OUT2  
Voltage output 12 V  
40 mA  
OUT1  
+
+
EV3(E), EV7(D)  
2
EV4(E), EV8(D)  
EV5(E), EV9(D)  
EV6(E), EV10(D)  
COM  
Voltage output 12 V  
40 mA or  
Current output  
3
4
5
6
6
F
F
G
H
I
J K  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output type setting.)  
+
1
2
3
4
1
OUT4  
2
Voltage output 12 V  
40 mA  
Input 2  
Input 1  
+
+
3
4
5
+
+
PT  
PT  
I
V
TC  
OUT3  
Voltage output 12 V  
40 mA or  
Current output  
+
5
6
G
6
+
+
TC  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
I
V
K
(Thermocouple)  
(Voltage)  
(Current)  
(Switched by output type setting.)  
(Resistance temperature input sensor)  
The power supply voltage must be 100 to 240 VAC or 24 VAC/DC for the E5AR-T to comply with CE  
marking requirements.  
Note  
The power supply voltage must be 100 to 120 VAC or 24 VAC/DC for the E5AR-T to comply with UL  
requirements.  
8
E5AR-T  
E5AR-TCCE3MWW-FLK (4-loop Control)  
E5AR-TQQE3MWW-FLK (4-loop Control)  
Auxiliary output  
(Transistor output)  
Auxiliary output  
(Transistor output)  
B C  
1
B C  
1
COM  
COM  
100 to 240 VAC  
24 VAC/DC  
+
100 to 240 VAC  
+
+
A
B
C
D
E
SUB1(B), SUB6(C)  
SUB2(B), SUB7(C)  
SUB3(B), SUB8(C)  
SUB1(B), SUB6(C)  
2
3
4
5
6
2
3
4
5
6
A
B C D E  
!
1
2
3
4
5
6
1
2
3
4
5
6
+
1
2
3
4
5
6
1
2
3
4
5
6
+
!
SUB2(B), SUB7(C)  
SUB3(B), SUB8(C)  
+
+
+
+
+
+
+
Input power supply  
depends on model.  
100 to 240 VAC or 24  
VAC/DC (no polarity)  
SUB4(B), SUB9(C)  
SUB5(B), SUB10(C)  
SUB4(B), SUB9(C)  
SUB5(B), SUB10(C)  
+
+
+
B(+)  
A()  
1
2
3
4
5
+
RS-485  
Event input D E  
1
B(+)  
1
Event input D E  
1
OUT2  
RS-485  
OUT2  
Current output  
A()  
Voltage output 12 V 21 mA  
2
+
EV3(E), EV7(D)  
2
3
4
5
6
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output  
3
4
5
EV3(E), EV7(D)  
2
3
4
5
6
OUT1  
+
EV4(E), EV8(D)  
Voltage output 12 V  
21 mA or  
Current output  
EV4(E), EV8(D)  
EV5(E), EV9(D)  
type setting.)  
EV5(E), EV9(D)  
EV6(E), EV10(D)  
COM  
6
F
OUT1  
F
G
H
I
J K  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output type setting.)  
F
G
H
I
J K  
Current output  
6
F
EV6(E), EV10(D)  
COM  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output type setting.)  
+
+
1
2
3
4
1
OUT4  
+
+
1
+
1
2
3
4
Input 2(K)  
Input 4(J)  
OUT4  
Current output  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output  
type setting.)  
2
3
4
5
6
+
+
Voltage output 12 V 21 mA  
+
Input 2(K)  
Input 4(J)  
2
3
4
5
6
+
I
+
+
V
V
PT  
PT  
TC  
+
OUT3  
Voltage output 12 V  
21 mA or  
+
I
V
V
PT  
PT  
TC  
+
5
6
G
Input 1(K)  
Input 3(J)  
Current output  
OUT3  
Current output  
5
Input 1(K)  
Input 3(J)  
+
TC  
4 to 20 mA DC, 500 max.  
0 to 20 mA DC, 500 max.  
I
4 to 20 mA DC, 500 max.  
6
G
+
TC  
(Thermocouple)  
(Voltage)  
(Current)  
0 to 20 mA DC, 500 max.  
I
(Switched by output type setting.)  
J, K  
(Resistance temperature input sensor)  
(Switched by output type setting.)  
(Thermocouple)  
(Voltage)  
(Current)  
(Resistance temperature input sensor)  
J, K  
E5AR-TPR4DF  
E5AR-TPRQE3MF-FLK  
Auxiliary output  
(Relay output)  
Auxiliary output  
(Transistor output)  
B
24 VAC/DC  
100 to 240 VAC  
A
B C D E  
B C  
1
+
+
COM  
1
2
3
4
5
6
1
24 VAC/DC  
100 to 240 VAC  
!
A
B
C
D
E
COM  
+
SUB1  
SUB2  
+
1
2
3
4
5
6
1
2
3
4
5
6
2
3
4
5
6
1
2
3
4
5
6
SUB1(B), SUB6(C)  
SUB2(B), SUB7(C)  
2
3
4
5
6
!
+
+
Input power supply  
depends on model.  
100 to 240 VAC or 24  
VAC/DC (no polarity)  
COM  
SUB3  
SUB4  
+
+
+
Input power supply  
SUB3(B), SUB8(C)  
SUB4(B), SUB9(C)  
SUB5(B), SUB10(C)  
depends on model.  
100 to 240 VAC or 24  
VAC/DC (no polarity)  
1
Event input  
E
1
Event input D E  
1
2
+
OUT4  
Voltage output 12 V  
40 mA  
OUT3  
Voltage output 12 V  
3
4
5
EV3  
EV4  
2
3
4
5
6
2
EV3(E), EV7(D)  
EV4(E), EV8(D)  
EV5(E), EV9(D)  
EV6(E), EV10(D)  
COM  
3
4
5
6
+
EV5  
EV6  
40 mA or  
Current output  
4 to 20 mA DC,  
500 max.  
0 to 20 mA DC, 500 max.  
(Switched by output type setting.)  
6
G
F
G
H
I
J K  
COM  
F
G
H
I
J K  
Potentiometer  
O
W
C
1
2
3
4
5
1
2
3
4
5
Potentiometer  
O
1
+
Relay output  
250 VAC 1 A  
B(+)  
1
2
3
4
5
RS-485  
W
2
A()  
Relay output  
250 VAC 1 A  
OUT2  
Closed  
+
C
3
+
+
+
OUT2  
OUT1  
Closed  
4
OUT1  
Open  
+
6
F
5
6
K
Open  
I
V
PT  
TC  
(Thermocouple)  
6
+
6
F
(Voltage)  
(Current)  
I
V
PT  
TC  
(Thermocouple)  
K
(Resistance temperature input sensor)  
(Voltage)  
(Current)  
(Resistance temperature input sensor)  
The power supply voltage must be 100 to 240 VAC or 24 VAC/DC for the E5AR-T to comply with CE  
marking requirements.  
Note  
The power supply voltage must be 100 to 120 VAC or 24 VAC/DC for the E5AR-T to comply with UL  
requirements.  
9
E5AR-T  
Nomenclature  
E5AR-T  
Rear  
SUB1 SUB2 SUB3 SUB4 WAIT  
FSP  
Operation  
Indicators  
Channel  
Indicator  
Display No. 1  
PV  
SV  
Display No. 2  
Display No. 3  
Bar Graph  
PRG.  
SEG  
Program Status  
Indicators  
CMW  
MANU  
OUT1 OUT2 OUT3 OUT4 RST  
PF1 PF2  
RSP HOLD  
RUN/RST  
Function Key 1/  
Run/Reset Key  
Function Key 2  
Level Key  
Mode Key  
Down Key  
Up Key  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
110  
95  
E5AR-T  
11.5  
3
96  
2
91 × 91  
SUB1 SUB2 SUB3 SUB4 WAIT FSP  
PV  
SV  
PRG.  
SEG  
96  
111  
CMW  
MANU  
OUT1 OUT2 OUT3 OUT4 RST  
PF1 PF2  
RSP HOLD  
RUN/RST  
Crimp terminal size: M3  
Terminal cover (E53-COV14: order separately)  
Panel Cutouts  
920+0.8  
110 min.  
920+0.8  
120 min.  
Recommended panel thickness is 1 to 8 mm.  
Group mounting is not possible. (Maintain the specified  
mounting space between Controllers.)  
When two or more Controllers are mounted, make sure  
that the surrounding temperature does not exceed the  
allowable operating temperature specified in the specifica-  
tions.  
10  
E5AR-T  
Accessories (Order Separately)  
Terminal Cover  
E53-COV14 (for E5AR)  
95  
95  
28.5  
10.1  
Unit Label Sheet  
Y92S-L1  
11.8  
4.8  
Rubber Packing  
Y92S-P4 (for DIN96 × 96)  
Order the Rubber Packing separately if it becomes lost or damaged. (Refer to page 2.)  
The Rubber Packing can be used to achieve an IP66 degree of protection.  
(Deterioration, shrinking, or hardening of the rubber packing may occur depending on the operating  
environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing  
specified in NEMA4. The time for periodic replacement depends on the operating environment. Be  
sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be lia-  
ble for the level of water resistance if the customer does not perform periodic replacement.)  
The Rubber Packing does not need to be attached if a waterproof structure is not required.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
11  
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.12  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

E5AR-TC43B-FLK

Programmable Digital Controller
OMRON

E5AR-TC43DW-FLK

Programmable Digital Controller
OMRON

E5AR-TC4B

Programmable Digital Controller
OMRON

E5AR-TCCE3MWWFLK

Programmable Digital Controller
OMRON

E5AR-TCE3MB-FLK

Programmable Digital Controller
OMRON

E5AR-TPR4DF

Programmable Digital Controller
OMRON

E5AR-TPRQE3MFFLK

Programmable Digital Controller
OMRON

E5AR-TQ43B-FLK

Programmable Digital Controller
OMRON

E5AR-TQ43DW-FLK

Programmable Digital Controller
OMRON

E5AR-TQ4B

Programmable Digital Controller
OMRON

E5AR-TQCE3MB-FLK

Programmable Digital Controller
OMRON

E5AR-TQE3MB-FLK

Programmable Digital Controller
OMRON