Basic-type Digital Temperature Controller
(48 x 48 mm)
E5CN/E5CN-U
CSM_E5CN_E5CN-U_DS_E_4_2
New 48 x 48-mm Basic Temperature
Controller with Enhanced Functions and
Performance. Improved Indication
Accuracy and Preventive Maintenance
Function.
• Indication Accuracy
48 × 48-mm
48 × 48-mm
Thermocouple input: ±±.3% of PV (previous models: ±±.5%)
Pt input: ±±.2% of PV (previous models: ±±.5%)
Analog input: ±±.2% FS (previous models: ±±.5%)
• New E5CN-U Models (Plug-in Models) with analog inputs and
current outputs.
E5CN
E5CN-U
Refer to Safety Precautions for E5@N/E5@N-H.
• A PV/SV-status display function can be set to automatically
alternate between displaying the status of the Temperature
Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV.
• Preventive maintenance for relays in the Temperature Controller
using a Control Output ON/OFF Counter.
Refer to Operation for E5@N/E5@N-H for operating
procedures.
Main I/O Functions
Event Inputs
E5CN
• None
• Two
4-digit Display
2-level Display: PV and SV
Sensor Inputs
• Auto/manual switching
• Universal thermocouple/Pt inputs
(Models with temperature inputs)
• Analog current/voltage inputs
(Models with analog inputs)
Auxiliary Outputs
• None
• Temperature Controller status display
• Simple program function
• One
• Control output ON/OFF count alarm
• PV change rate alarm
Control Output 2
• None
• Two
• Models also available with RS-485
communications
• Voltage output
(for driving SSR)
Indication Accuracy
• Thermocouple input: ±.3% of PV
• Pt input: ±.2% of PV
Control Output 1
• Relay output
• Analog input: ±.2% FS
• Voltage output (for driving SSR)
• Current output
Sampling Period
• 25± ms
• Long-life relay output (hybrid)
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)
1
E5CN/E5CN-U
Lineup
0 or 2 auxiliary outputs
1 control output
2 control outputs
1 control output
2 control outputs
1 control output
1 control output
Temperature input
Analog input
2 auxiliary outputs
Terminal block
0 or 2 auxiliary outputs
E5CN
2 auxiliary outputs
Basic Type
0, 1, or 2 auxiliary
outputs
Temperature input
Analog input
Plug-in
0, 1, or 2 auxiliary
outputs
Note: Models with one control output and one or two auxiliary outputs and models with two control outputs can be used for heating/cooling control.
Model Number Structure
Model Number Legend
Controllers
Option Units
E5CN-@@M@@-@-500
E53-CN@@@
4
2 3
1 2 3 4 5
6
7
1
1. Control Output 1
1. Applicable Controller
R: Relay output
CN: E5CN or E5CN-H
Q: Voltage output (for driving SSR)
C: Current output
Y: Long-life relay output (hybrid) *1
2. Function 1
Blank: None
Q: Control output 2 (voltage for driving SSR)
P: Power supply for sensor
2. Auxiliary Outputs *2
Blank: None
3. Function 2
2: Two outputs
Blank: None
3. Option
H: Heater burnout/SSR failure/Heater overcurrent detection (CT1)
M: Option Unit can be mounted.
HH: Heater burnout/SSR failure/Heater overcurrent detection
(CT2)
B: Two event inputs
03: RS-485 communications
H03: Heater burnout/SSR failure/Heater overcurrent detection
(CT1) + RS-485 communications
HB: Heater burnout/SSR failure/Heater overcurrent detection
(CT1) + Two event inputs
HH03: Heater burnout/SSR failure/Heater overcurrent detection
(CT2) + RS-485 communications
4. Input Type
T: Universal thermocouple/platinum resistance thermometer
L: Analog current/voltage input
5. Power Supply Voltage
Blank: 100 to 240 VAC
D: 24 VAC/VDC
6. Case Color
Blank: Black
W: Silver
4. Version
N2: Applicable only to models released after January 2008
7. Terminal Cover
-500: With terminal cover
Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@).
*1. Always connect an AC load to a long-life relay output. The output will not turn OFF if a DC load is connected because a triac is used for
switching the circuit. For details, check the conditions in Ratings.
*2. Auxiliary outputs are contact outputs that can be used to output alarms or results of logic operations.
2
E5CN/E5CN-U
Ordering Information
Controllers with Terminal Blocks
Power supply
Size
Case color
Input type
Auxiliary outputs
Control output 1
Relay output
Model
voltage
E5CN-RMT-500
None
Voltage output (for driving SSR)
Current output
E5CN-QMT-500
E5CN-CMT-500
Thermocouple or
Resistance
thermometer
100 to 240 VAC
Relay output
E5CN-R2MT-500
E5CN-Q2MT-500
E5CN-C2MT-500
E5CN-Y2MT-500
E5CN-RMTD-500
E5CN-QMTD-500
E5CN-CMTD-500
E5CN-R2MTD-500
E5CN-Q2MTD-500
E5CN-C2MTD-500
E5CN-RML-500
Voltage output (for driving SSR)
Current output
2
Long-life relay output (hybrid)
Relay output
None
2
Voltage output (for driving SSR)
Current output
Thermocouple or
Resistance
thermometer
24 VAC/VDC
Relay output
Black
Voltage output (for driving SSR)
Current output
Relay output
None
Voltage output (for driving SSR)
Current output
E5CN-QML-500
E5CN-CML-500
1/16 DIN
48 × 48 × 78
(W × H × D)
Analog
(current/voltage)
100 to 240 VAC
24 VAC/VDC
Relay output
E5CN-R2ML-500
E5CN-Q2ML-500
E5CN-C2ML-500
E5CN-Y2ML-500
E5CN-R2MLD-500
E5CN-Q2MLD-500
E5CN-C2MLD-500
E5CN-RMT-W-500
E5CN-QMT-W-500
E5CN-CMT-W-500
E5CN-R2MT-W-500
E5CN-Q2MT-W-500
E5CN-C2MT-W-500
E5CN-Y2MT-W-500
E5CN-R2MTD-W-500
E5CN-Q2MTD-W-500
E5CN-C2MTD-W-500
Voltage output (for driving SSR)
Current output
2
Long-life relay output (hybrid)
Relay output
Analog
(current/voltage)
2
Voltage output (for driving SSR)
Current output
Relay output
None
Voltage output (for driving SSR)
Current output
100 to 240 VAC
24 VAC/VDC
Relay output
Thermocouple or
Resistance
thermometer
Voltage output (for driving SSR)
Current output
Silver
2
2
Long-life relay output (hybrid)
Relay output
Voltage output (for driving SSR)
Current output
Note: Models with analog inputs do not have temperature unit indicators.
Option Units
One of the following Option Units can be mounted to provide the E5CN with additional functions.
Functions
Model
Communications
RS-485
3-phase heater burnout/SSR failure/
Heater overcurrent detection
E53-CNHH03N2
Heater burnout/SSR failure/Heater
overcurrent detection
Event inputs
Event inputs
E53-CNHBN2
E53-CNQ03N2
Communications
RS-485
Control output 2
(Voltage for driving SSR)
External power supply for
ES1B
E53-CNPBN2
E53-CNPHN2
E53-CNP03N2
E53-CNH03N2
Heater burnout/SSR failure/Heater
overcurrent detection
External power supply for
ES1B
Communications
RS-485
External power supply for
ES1B
Communications
RS-485
Heater burnout/SSR failure/Heater
overcurrent detection
Communications
RS-485
E53-CN03N2
E53-CNBN2
E53-CNQHN2
Event inputs
Event inputs
Heater burnout/SSR failure/Heater
overcurrent detection
Control output 2
(Voltage for driving SSR)
3-phase heater burnout/SSR failure/
Heater overcurrent detection
Control output 2
(Voltage for driving SSR)
E53-CNQHHN2
E53-CNQBN2
Control output 2
(Voltage for driving SSR)
Note: Option Units cannot be used for plug-in models.
These Option Units are applicable only to models released after January 2008.
3
E5CN/E5CN-U
Model Number Structure
Model Number Legend (Plug-in-type Controllers)
E5CN-@@@U
1 2 3 4
1. Output Type
3. Input Type
R: Relay output
T: Universal thermocouple/platinum resistance thermometer
Q: Voltage output (for driving SSR)
C: Current output
2. Number of Alarms
Blank: No alarm
L: Analog Input
4. Plug-in type
U: Plug-in type
1: One alarm
2: Two alarms
Ordering Information
Plug-in-type Controllers
Power supply
Size
Case color
Input type
Auxiliary outputs
Control output 1
Relay output
Voltage output (for driving SSR) E5CN-QTU
Model
voltage
E5CN-RTU
None
Current output
Relay output
E5CN-CTU
E5CN-R1TU
Thermocouple or
resistance
thermometer
1
Voltage output (for driving SSR) E5CN-Q1TU
Current output
Relay output
E5CN-C1TU
E5CN-R2TU
100 to 240 VAC
2
Voltage output (for driving SSR) E5CN-Q2TU
Current output
Relay output
E5CN-C2TU
E5CN-R1LU
1
Voltage output (for driving SSR) E5CN-Q1LU
Current output
Relay output
E5CN-C1LU
E5CN-R2LU
Analog
(current/voltage)
1/16 DIN
Black
2
Voltage output (for driving SSR) E5CN-Q2LU
Current output
Relay output
E5CN-C2LU
E5CN-RTDU
None
Voltage output (for driving SSR) E5CN-QTDU
Current output
Relay output
E5CN-CTDU
E5CN-R1TDU
Thermocouple or
resistance
thermometer
24 VAC/VDC
1
2
Voltage output (for driving SSR) E5CN-Q1TDU
Current output
Relay output
E5CN-C1TDU
E5CN-R2TDU
Voltage output (for driving SSR) E5CN-Q2TDU
Current output E5CN-C2TDU
Note: Models with analog inputs do not have temperature unit indicators.
4
E5CN/E5CN-U
Accessories (Order Separately)
USB-Serial Conversion Cable
Adapter
Model
Connectable models
Terminal block models
Model
E58-CIFQ1
Y92F-45
Note: Use this Adapter when the panel has been previously prepared
for the E5B@.
Terminal Cover
Connectable models
Model
Sockets (for Plug-in Models)
Terminal block models
E53-COV17
Type
Front-connecting Socket
Model
Note: The Terminal Cover comes with the E5CN-@@@-500 models.
P2CF-11
P2CF-11-E
P3GA-11
Waterproof Packing
Front-connecting Socket with Finger Protection
Back-connecting Socket
Model
Terminal Cover for Back-connecting socket with
Finger Protection
Y92S-29
Y92A-48G
Note: The Waterproof Packing is included with the Controller only for
models with terminal blocks.
Front cover
Current Transformers (CTs)
Type
Hard Front Cover
Model
Hole diameter
5.8 dia.
Model
Y92A-48B
Y92A-48D
E54-CT1
E54-CT3
Soft Front Cover
12.0 dia.
CX-Thermo Support Software
Model
EST2-2C-MV4
5
E5CN/E5CN-U
Specifications
Ratings
No D in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Power supply voltage
Operating voltage range
85% to 110% of rated supply voltage
100 to 240 VAC: 7.5 VA (max.) (E5CN-R2T at 100 VAC: 3.0 VA)
24 VAC/VDC: 5 VA/3 W (max.) (E5CN-R2TD at 24 VAC: 2.7 VA)
E5CN
Power
consump-
tion
100 to 240 VAC: 6 VA (max.)
24 VAC/VDC: 3 VA/2 W (max.) (models with current output: 4 VA/2 W)
E5CN-U
Models with temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Voltage input: 0 to 50 mV
Sensor input
Models with analog inputs
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance
Control method
Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB.)
ON/OFF control or 2-PID control (with auto-tuning)
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
load: 5 V, 10 mA
E5CN
Relay output
SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load:
5 V, 10 mA
E5CN-U
Control
outputs
Voltage output
(for driving SSR)
E5CN
E5CN-U circuit
Output voltage: 12 VDC 15% (PNP), max. load current: 21 mA, with short-circuit protection
Current output
E5CN
E5CN
4 to 20 mA DC/0 to 20 mA DC, load: 600 Ω max., resolution: approx. 10,000
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 1,000,000 operations, load power supply
voltage: 75 to 250 VAC (DC loads cannot be connected.), minimum applicable load: 5 V, 10 mA,
leakage current: 5 mA max. (250 VAC, 60 Hz)
Long-life relay
output
Number of outputs 1 or 2 max. (Depends on the model.)
Auxiliary
outputs
Output
Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
applicable load: 5 V, 10 mA
specifications
Number of inputs
2
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Event
inputs
External contact
input
specifications
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
External power supply for ES1B 12 VDC 10%, 20 mA, short-circuit protection circuit provided
Setting method
Digital setting using front panel keys
11-segment digital display and individual indicators (7-segment display also possible)
Character height: PV: 11 mm, SV: 6.5 mm
Indication method
Up to four set points (SP0 to SP3) can be saved and selected using event inputs, key operations, or serial
communications.
Multi SP
Bank switching
Not supported
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout
detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop,
protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, logic
operations, PV/SV status display, simple program, automatic cooling coefficient adjustment
Other functions
Ambient operating temperature −10 to 55°C (with no condensation or icing), for 3-year warranty: −10 to 50°C
Ambient operating humidity
Storage temperature
25% to 85%
−25 to 65°C (with no condensation or icing)
6
E5CN/E5CN-U
Input Ranges
Thermocouple/Platinum Resistance Thermometer (Universal Inputs)
Input
Type
Platinum resistance
thermometer
Infrared temperature Analog
Thermocouple
sensor
input
115
140
to
260
°C
60to
120
°C
PL
II
0 to
50 mV
10to
70°C
to
165
°C
Name
Pt100
JPt100
K
J
T
E
L
U
N
R
S
B
W
2300
2300
1800
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
1700 1700
1300
1300
1300
Usable
in the
following
ranges
by
850
850
850
800
scaling:
−1999 to
9999 or
−199.9
to 999.9
700
600
600
500.0
500.0
500.0
500
400.0 400 400.0
400 400.0
400
260
300
120
0
165
0
200
100.0
0.0
100.0
90
0
100
100
0
0.0
0
0
0
0
0
−100.0
−200.0
−20.0 −100 −20.0
−100
−200 −199.9
−199.9
−200
−200 −199.9 −200
−200 −199.9 −200
Setting
number
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 24 25
19
20
21
22
23
Shaded settings are the default settings.
The applicable standards for the input types are as follows:
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1
L: Fe-CuNi, DIN 43710-1985
JPt100: JIS C 1604-1989, JIS C 1606-1989
Pt100: JIS C 1604-1997, IEC 751
U: Cu-CuNi, DIN 43710-1985
PL II: According to Platinel II electromotive force charts from BASF (previously
Engelhard)
W: W5Re/W26Re, ASTM E988-1990
Models with Analog Inputs
Input Type
Current
Voltage
0 to 5 V
Input specification
4 to 20mA 0 to 20 mA
1 to 5 V
0 to 10 V
Usable in the following ranges by scaling:
−1999 to 9999, −199.9 to 999.9, −19.99 to 99.99 or −1.999 to 9.999
Setting range
Setting number
0
1
2
3
4
Shaded settings are the default settings.
7
E5CN/E5CN-U
Alarm Outputs
Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit.
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the
following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR
failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function).
Alarm output operation
Set value
Alarm type
Alarm function OFF
Description of function
When alarm value When alarm value
X is positive
X is negative
0
Output OFF
No alarm
L
H
Set the deviation in the set point by setting the alarm
upper limit (H) and alarm lower limit (L).
ON
OFF
1 *1
2
Upper- and lower-limit
Upper-limit
*2
SP
X
X
Set the upward deviation in the set point by setting
the alarm value (X).
ON
OFF
ON
OFF
SP
SP
X
X
ON
OFF
ON
OFF
Set the downward deviation in the set point by setting
the alarm value (X).
3
Lower-limit
SP
SP
L
H
Set the deviation in the set point by setting the alarm
upper limit (H) and alarm lower limit (L).
ON
OFF
4 *1
Upper- and lower-limit range
*3
*4
SP
L
H
ON
OFF
Upper- and lower-limit with
standby sequence
A standby sequence is added to the upper- and
lower-limit alarm (1). *6
5 *1
SP
*5
ON
X
X
A standby sequence is added to the upper-limit alarm
(2). *6
ON
OFF
6
7
Upper-limit with standby sequence
Lower-limit with standby sequence
OFF
SP
SP
X
X
ON
OFF
A standby sequence is added to the lower-limit alarm
(3). *6
ON
OFF
SP
X
SP
X
ON
OFF
The alarm will turn ON if the process value is larger
than the alarm value (X) regardless of the set point.
ON
OFF
8
9
Absolute-value upper-limit
Absolute-value lower-limit
0
0
0
0
X
X
ON
OFF
ON
OFF
The alarm will turn ON if the process value is smaller
than the alarm value (X) regardless of the set point.
X
X
X
X
Absolute-value upper-limit with
standby sequence
ON
OFF
A standby sequence is added to the absolute-value
upper-limit alarm (8). *6
ON
OFF
10
11
0
0
0
0
Absolute-value lower-limit with
standby sequence
A standby sequence is added to the absolute-value
lower-limit alarm (9). *6
ON
OFF
ON
OFF
12
13
LBA (alarm 1 type only)
PV change rate alarm
---
---
*7
*8
*1. With set values 1, 4 and 5, the upper and lower limit values can
be set independently for each alarm type, and are expressed as
“L” and “H.”
*5. Set value: 5, Upper- and lower-limit with standby sequence
Always OFF when the upper-limit and lower-limit hysteresis
overlaps.
*6. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
Controllers User's Manual Basic Type (Cat. No. H156) for
information on the operation of the standby sequence.
*7. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
Controllers User's Manual Basic Type (Cat. No. H156) for
information on the loop burnout alarm (LBA).
*2. Set value: 1, Upper- and lower-limit alarm
Case 2
Case 1
Case 3 (Always ON)
H < 0, L < 0
H
SP
L
SP L
H
L
H SP
H < 0, L > 0
⏐H⏐ ≥ ⏐L⏐
H < 0, L > 0
⏐H⏐ < ⏐L⏐
H > 0, L < 0
⏐H⏐ > ⏐L⏐
H
L SP
*8. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature
Controllers User's Manual Basic Type (Cat. No. H156) for
information on the PV change rate alarm.
H > 0, L < 0
SPH
L
⏐H⏐ ≤ ⏐L⏐
*3. Set value: 4, Upper- and lower-limit range
Case 3 (Always OFF)
Case 1
Case 2
H < 0, L < 0
H
SP
L
L
H SP
SP L
H
H < 0, L > 0
H < 0, L > 0
H > 0, L < 0
⏐H⏐ ≥ ⏐L⏐
H
L SP
⏐H⏐ < ⏐L⏐
⏐H⏐ > ⏐L⏐
H > 0, L < 0
⏐H⏐ ≤ ⏐L⏐
L
SP H
*4. Set value: 5, Upper- and lower-limit with standby sequence
For Upper- and Lower-Limit Alarm Described Above
• Case 1 and 2
Always OFF when the upper-limit and lower-limit hysteresis
overlaps.
• Case 3: Always OFF
8
E5CN/E5CN-U
Characteristics
Thermocouple: *1
Terminal block models (E5CN): ( 0.3% of indicated value or 1°C, whichever is greater) 1 digit max.
Plug-in models (E5CN-U): ( 1% of indicated value or 2°C, whichever is greater) 1 digit max.
Platinum resistance thermometer input:
Terminal block models (E5CN) and plug-in models (E5CN-U): ( 0.2% of indicated value or 0.8°C, whichever is greater) 1 digit max.
Analog input:
Indication accuracy
Terminal block models (E5CN) and plug-in models (E5CN-U): 0.2% FS 1 digit max.
CT input:
Terminal block models (E5CN): 5% FS 1 digit max.
Thermocouple input (R, S, B, W, PL II):
Terminal block models (E5CN): ( 1% of PV or 10°C, whichever is greater) 1 digit max.
Plug-in models (E5CN-U): ( 2% of PV or 10°C, whichever is greater) 1 digit max.
Other thermocouple input: *3
Terminal block models (E5CN): ( 1% of PV or 4°C, whichever is greater) 1 digit max.
Plug-in models (E5CN-U): ( 2% of PV or 4°C, whichever is greater) 1 digit max.
Platinum resistance thermometer input:
Terminal block models (E5CN) and plug-in models (E5CN-U):
( 1% of PV or 2°C, whichever is greater) 1 digit max.
Analog input:
Influence of temperature *2
Influence of voltage *2
Terminal block models (E5CN) and plug-in models (E5CN-U): ( 1%FS) 1 digit max.
Input sampling period
Hysteresis
250 ms
Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) *4
Models with analog input: 0.01 to 99.99% FS (in units of 0.01% FS)
Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) *4
Models with analog input: 0.1 to 999.9% FS (in units of 0.1% FS)
Proportional band (P)
Integral time (I)
0 to 3999 s (in units of 1 s)
Derivative time (D)
Control period
0 to 3999 s (in units of 1 s) *5
0.5, 1 to 99 s (in units of 1 s)
Manual reset value
Alarm setting range
0.0 to 100.0% (in units of 0.1%)
−1999 to 9999 (decimal point position depends on input type)
Affect of signal source
resistance
Thermocouple: 0.1°C/Ω max. (100 Ω max.)
Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)
Insulation resistance
Dielectric strength
20 MΩ min. (at 500 VDC)
2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)
10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions
100 m/s2, 3 times each in X, Y, and Z directions
Malfunction
Vibration
resistance
Destruction
Malfunction
Destruction
E5CN
Shock
resistance
300 m/s2, 3 times each in X, Y, and Z directions
Controller: Approx. 150 g, Mounting Bracket: Approx. 10 g
Controller: Approx. 110 g, Mounting Bracket: Approx. 10 g
Front panel: IP66, Rear case: IP20, Terminals: IP00
Front panel: IP50, Rear case: IP20, Terminals: IP00
Non-volatile memory (number of writes: 1,000,000 times)
CX-Thermo version 4.0 or higher
Weight
E5CN-U
E5CN
Degree of
protection
E5CN-U
Memory protection
Setup Tool
Provided on the bottom of the E5CN. Use this port to connect a computer to the E5CN when using the Setup Tool. An E58-CIFQ1
USB-Serial Conversion Cable is required to connect the computer to the E5CN. *6
Setup Tool port
Approved
standards *7
UL 61010-1, CSA C22.2 No. 1010-1, KOSHA certified (some models) *8
Standards
Conformed
standards
EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *9
EMI:
EN 61326
Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A
Noise Terminal Voltage:
EMS:
ESD Immunity:
Electromagnetic Field Immunity:
Burst Noise Immunity:
Conducted Disturbance Immunity:
Surge Immunity:
EN 55011 Group 1, class A
EN 61326
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
EN 61000-4-5
EN 61000-4-8
EN 61000-4-11
EMC
Power Frequency Magnetic Field Immunity:
Voltage Dip/Interrupting Immunity:
*1. The indication accuracy of K thermocouples in the −200 to 1300°C range, T and N thermocouples at a temperature of −100°C max., and U
and L thermocouples at any temperatures is 2°C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max.
is not specified. The indication accuracy of B thermocouples in the 400 to 800°C range is 3°C max. The indication accuracy of the R and S
thermocouples at a temperature of 200°C max. is 3°C 1 digit max. The indication accuracy of W thermocouples is 0.3 of PV or 3°C,
whichever is greater, 1 digit max. The indication accuracy of PL II thermocouples is 0.3 of PV or 2°C, whichever is greater, 1 digit max.
*2. Ambient temperature: −10°C to 23°C to 55°C, Voltage range: −15% to 10% of rated voltage
*3. K thermocouple at −100°C max.: 10° max.
*4. “EU” stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is °C or °F.
*5. When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s).
*6. External communications (RS-485) and cable communications for the Setup Tool can be used at the same time.
*7. The E5CN-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket.
The P3GA-11 is not certified for UL listing.
*8. Access the following website for information on certified models. http://www.ia.omron.com/support/models/index.html
*9. Refer to information on maritime standards in Safety Precautions for E5@N/E5@N-H for compliance with Lloyd's Standards.
9
E5CN/E5CN-U
USB-Serial Conversion Cable
Current Transformer (Order Separately)
Ratings
Applicable OS
Windows 2000, XP, or Vista
Applicable software
CX-Thermo version 4 or higher
Dielectric strength
1,000 VAC for 1 min
E5AN/E5EN/E5CN/E5CN-U/E5AN-H/
E5EN-H/E5CN-H/E5GN
Vibration resistance 50 Hz, 98 m/s2
Applicable models
E54-CT1: Approx. 11.5 g,
Weight
USB interface standard Conforms to USB Specification 1.1.
E54-CT3: Approx. 50 g
DTE speed
38400 bps
Accessories
Armatures (2)
Plugs (2)
(E54-CT3 only)
Computer: USB (type A plug)
Temperature Controller: Setup Tool port
(on bottom of Controller)
Connector
specifications
Heater Burnout Alarms, SSR Failure
Alarms, and Heater Overcurrent Alarms
Bus power (Supplied from USB host
controller.)
Power supply
Models with detection for single-phase
heaters: One input
Models with detection for single-phase
or three-phase heaters: Two inputs
CT input
Power supply voltage
Current consumption
5 VDC
70 mA
(for heater current
detection)
Ambient operating
temperature
0 to 55°C (with no condensation or icing)
10% to 80%
Maximum heater current 50 A AC
Ambient operating
humidity
Input current indication
5% FS 1 digit max.
accuracy
−20 to 60°C (with no condensation or
icing)
Heater burnout alarm
setting range *1
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms
Storage temperature
Storage humidity
Altitude
10% to 80%
2,000 m max.
Approx. 100 g
SSR failure alarm
setting range *2
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection OFF time: 100 ms
Heater overcurrent
alarm setting range *3 Minimum detection ON time: 100 ms
0.1 to 49.9 A (in units of 0.1 A)
Weight
Note: A driver must be installed in the personal computer. Refer to
installation information in the operation manual for the
Conversion Cable.
*1. For heater burnout alarms, the heater current will be measured
when the control output is ON, and the output assigned to the
alarm 1 function will turn ON if the heater current is lower than the
set value (i.e., heater burnout detection current value).
*2. For SSR failure alarms, the heater current will be measured when
the control output is OFF, and the output assigned to the alarm 1
function will turn ON if the heater current is higher than the set
value (i.e., SSR failure detection current value).
*3. For heater overcurrent alarms, the heater current will be
measured when the control output is ON, and the output assigned
to the alarm 1 function will turn ON if the heater current is higher
than the set value (i.e., heater overcurrent detection current
value).
Communications Specifications
Transmission line
RS-485: Multipoint
connection method
Communications
RS-485 (two-wire, half duplex)
Synchronization
method
Start-stop synchronization
Protocol
CompoWay/F, SYSWAY, or Modbus
1200, 2400, 4800, 9600, 19200, 38400, or
57600 bps
Baud rate
Electrical Life Expectancy Curve for
Relays (Reference Values)
Transmission code ASCII
Data bit length *
Stop bit length *
7 or 8 bits
500
1 or 2 bits
300
Vertical parity (none, even, odd)
Frame check sequence (FCS) with SYSWAY
Block check character (BCC) with
CompoWay/F or CRC-16 Modbus
100
Error detection
50
30
Flow control
Interface
None
RS-485
None
10
Retry function
Communications
buffer
5
E5CN
250 VAC, 30 VDC
(resistive load)
cosφ = 1
217 bytes
0 to 99 ms
3
Communications
response wait time Default: 20 ms
1
0
1
2
3
4
5
6
* The baud rate, data bit length, stop bit length, and vertical parity can
be individually set using the Communications Setting Level.
Switching current (A)
Note: Do not connect a DC load to a Controller with a Long-life Relay
Output.
10
E5CN/E5CN-U
External Connections
• A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple,
do not connect any of the control output terminals to ground. (If the control output terminals are connected to ground, errors will occur in the
measured temperature values as a result of leakage current.)
• Consult with your OMRON representative before using the external power supply for the ES1B for any other purpose.
E5CN
Controllers
Control output 1
The E5@N-@@@T@ is set for a K-type
thermocouple (input type = 5) by default. An
input error (s.err) will occur if the input type
setting does not agree with the temperature
sensor. Check the input type.
Long-life relay output
250 VAC, 3 A (resistive load)
Relay output
250 VAC, 3 A (resistive load)
Voltage output (for driving SSR)
12 VDC, 21 mA
Auxiliary outputs (relay outputs)
250 VAC, 3 A
(resistive load)
Current output
0 to 20 mA DC
4 to 20 mA DC
Load: 600 Ω max.
Auxiliary outputs
(relay outputs)
Control output 1
Auxiliary output 2
Auxiliary output 1
Control output 2
Voltage output (for driving SSR)
12 VDC, 21 mA
A
B
B
DO NOT
USE
DO NOT
USE
mA
A heater burnout alarm, heater short alarm,
heater overcurrent alarm, or input alarm is
sent to the output to which the alarm 1
function is assigned.
V
Input power supply
DO NOT
USE
• 100 to 240 VAC
• 24 VAC/VDC (no polarity)
TC/Pt
universal input
Analog input
Option Units
E53-CNPHN2
External Power
Supply and CT
E53-CNP03N2
Communications (RS-485)
and External Power Supply
E53-CNPBN2
Event Inputs and
External Power Supply
E53-CNHH03N2
Communications
(RS-485) and CT2
E53-CNHBN2
Event inputs
and CT
E53-CNQ03N2
Communications
(RS-485) and
Control Output 2
B(+)
11
RS-485
B(+)
11
11
11
B(+)
11
RS-485
+
External
11
12
13
14
15
12 VDC,
20 mA
RS-485
power supply
12
12
12
13
14
15
12
A(−)
EV1
EV1
EV2
A(−)
12
−
A(−)
13
13
DO NOT
13
14
15
DO NOT
EV2
DO NOT
13
USE
USE
CT2
USE
14
15
+
14
15
+
External
External
+
12 VDC,
20 mA
CT1
12 VDC,
20 mA
14
CT1
power supply
power supply
CT1
Control output 2
−
−
15
−
E53-CNH03N2
Communications
(RS-485) and CT
E53-CN03N2
Communications
(RS-485)
E53-CNBN2
Event inputs
E53-CNQHN2
Control Output 2
and CT
E53-CNQHHN2
Control Output 2
and CT2
E53-CNQBN2
Event Inputs and
Control Output 2
B(+)
11
RS-485
+
B(+)
11
RS-485
+
11
11
11
11
Control output 2
Control output 2
12
12
12
12
−
12
12
−
A(−)
EV1
A(−)
EV1
DO NOT
DO NOT
13
13
14
15
13
13
14
15
DO NOT
USE
DO NOT
USE
13
13
EV2
+
USE
EV2
DO NOT
USE
CT2
14
15
14
14
14
USE
CT1
Control output 2
CT1
CT1
DO NOT
15
15
15
DO NOT
−
USE
USE
E5CN-U
The E5@N-@@@T@ is set for a
K-type thermocouple (input type = 5)
by default. An input error (s.err) will
occur if the input type setting does
not agree with the temperature
sensor. Check the input type.
Auxiliary output
250 VAC, 3 A (resistive load)
(Relay outputs)
Control output 1
Control output 1
Auxiliary output 1
Auxiliary output 2
Relay output
(three terminals used)
SPDT, 250 VAC, 3 A
(resistive load)
Voltage output
(for driving SSR)
(Control output (cooling side))
A
B
DO NOT
USE
DO NOT
USE
An input error is sent to the
output to which the alarm 1
function is assigned.
mA
12 VDC, 21 mA
Current output
4 to 20 mA DC
0 to 20 mA DC
Load: 600 W max.
V
DO NOT
USE
Input power supply
B
• 100 to 240 VAC
• 24 VAC/VDC (no polarity)
Analog input
TC/Pt
universal input
Note: For the Wiring Socket, purchase the P2CF-11 or PG3A-11 separately.
11
E5CN/E5CN-U
Nomenclature
E5CN
Temperature unit
E5CN-U
The front panel is the same for the E5CN and E5CN-U.
No.1 display
Operation indicators
No. 2 display
Up Key
Level Key
Mode Key
Down Key
Dimensions
(Unit: mm)
E5CN
Panel Cutout
Terminal Models
Mounted Separately
Group Mounted
91
(48 × number of units − 2.5)+1.0
0
6
78
48 × 48
1.5
45+0.6
0
Group mounting does not
allow waterproofing.
58
60 min.
44.8 × 44.8 48.8
•
•
Recommended panel thickness is 1 to
5 mm.
45+0.6
0
Group mounting is not possible in the
vertical direction. (Maintain the specified
mounting space between Controllers.)
To mount the Controller so that it is
waterproof, insert the waterproof packing
onto the Controller.
Waterproof
Packing
(Accessory)
Mounting Adapter
(Accessory)
Terminal Cover
(E53-COV17)
(Accessory)
45+0.6
0
•
•
When two or more Controllers are
mounted, make sure that the surrounding
temperature does not exceed the
allowable operating temperature
specified in the specifications.
Note: The terminal block cannot be removed.
E5CN-U
Plug-in Models
Panel Cutout
Mounted Separately
(84.7)
Group Mounted
14.2
(48 × number of units − 2.5)+1.0
6
48 × 48
70.5
0
45+0.6
0
58
44.8 × 44.8
60 min.
•
•
Recommended panel thickness is 1 to 5
mm.
Group mounting is not possible in the
vertical direction. (Maintain the specified
mounting space between Controllers.)
When two or more Controllers are
mounted, make sure that the surrounding
temperature does not exceed the
allowable operating temperature specified
in the specifications.
45+0.6
0
Mounting Adapter
(Accessory)
•
45+0.6
0
Accessories (Order Separately)
USB-Serial Conversion Cable
E58-CIFQ1
(2,100)
LED indicator (SD)
1,765
250
USB connector (type A plug)
Serial connector
LED indicator (RD)
12
E5CN/E5CN-U
Waterproof Packing
Y92S-29 (for DIN 48 × 48)
Terminal Cover
E53-COV17
Order the Waterproof Packing separately if it becomes lost or
damaged.
The Waterproof Packing can be used to achieve an IP66 degree of
protection.
Note: The E53-COV10
cannot be used.
(Deterioration, shrinking, or hardening of the waterproof packing may
occur depending on the operating environment. Therefore, periodic
replacement is recommended to ensure the level of waterproofing
specified in IP66. The time for periodic replacement depends on the
operating environment. Be sure to confirm this point at your site.
Consider one year a rough standard. OMRON shall not be liable for
the level of water resistance if the customer does not perform periodic
replacement.)
48
48.8
The Waterproof Packing does not need to be attached if a waterproof
structure is not required.
22
9.1
Current Transformers
E54-CT1
E54-CT1
21
15
Thru-current (Io) vs. Output Voltage
(Eo) (Reference Values)
2.8
5.8 dia.
7.5
Maximum continuous heater current: 50 A (50/60 Hz)
Number of windings: 400 2
Winding resistance: 18 2 Ω
25
3
100 V
50 Hz
10.5
∞
1 kΩ
10
40
Distortion
factor 10%
Two, 3.5 dia.
1
100 mV
10
3%
1%
10
30
30
100 Ω
E54-CT3
RL = 10 Ω
1
2.36 dia.
12 dia.
100 µV
9
10
1
10
100 mA
1
10
100 1,000 A
Thru-current (Io) A (r.m.s.)
40 × 40
E54-CT3
Thru-current (Io) vs. Output Voltage
(Eo) (Reference Values)
Two, M3 (depth: 4)
Maximum continuous heater current: 120 A (50/60 Hz)
(Maximum continuous heater current for the
Temperature Controller is 50 A.)
15
Number of windings: 400 2
Winding resistance: 8 0.8 Ω
30
100 V
50 Hz
Distor-
E54-CT3 Accessory
• Armature
tion
∞
Connection Example
10
factor
10%
3%
1 kΩ
500 Ω
Armature
Plug
Approx. 3 dia.
1%
1
100 mV
10
Lead
100 Ω
50 Ω
18
RL = 10 Ω
1
• Plug
100 µV
Approx. 6 dia.
10
1
10
100 mA
1
10
100 1,000 A
(22)
Thru-current (Io) A (r.m.s.)
13
E5CN/E5CN-U
Adapter
Y92F-45
Note: 1. Note: 1. Use this Adapter when the panel has already been prepared for the E5B@.
2. The Adapter is available only in black.
Fixture (Accessory)
4.7
76
69.6 to 77.6
72 × 72
67 × 67 87
Mounted to E5CN
Panel (1 to 8 mm)
72 × 72
48 × 48
2.2
4.7
77.3 (to back of E5CN)
E5CN-U Wiring Socket
Front-connecting Socket
P2CF-11
Terminal Layout/Internal Connections
(Top View)
3
4.5
Eleven, M3.5 × 7.5
sems screws
7.8
8
7 6 5
Mounting Holes
4
Two, 4.5 dia. mounting holes
35.4
70 max.
Two,
4.5-dia.
holes
0.2
40
9
3
10 11 1 2
Note: Can also be mounted to a DIN track.
4
50 max.
31.2 max.
Note: A model with finger protection (P2CF-11-E) is also available.
Back-connecting Socket
P3GA-11
Terminal Layout/Internal Connections
(Bottom View)
27 dia.
4
7
3
5
6
7 8
4
45
25.6
3
9
2
1
11 10
45
4.5 16.3 6.2
6
8.7
Note: 1. Using any other sockets will adversely affect accuracy. Use only the specified sockets.
2. A Protective Cover for finger protection (Y92A-48G) is also available.
14
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
·
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2009.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2009 All Right Reserved.