G2R-1-H-DC100 [OMRON]

Power/Signal Relay, 1 Form A, SPST, Latched, 16A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output;
G2R-1-H-DC100
型号: G2R-1-H-DC100
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, 1 Form A, SPST, Latched, 16A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output

文件: 总14页 (文件大小:2867K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
G2R  
PCB Power Relay  
The Best Seller G2R  
• 1General purpose power Relays of single-pole10 A and double-pole 5 A.  
• Safety-oriented design with dielectric strength of 5,000 V between coil  
and contacts, and surge resistance of 10,000 V.  
• AC and DC types are both available for operational coils.  
RoHS Compliant  
Model Number Legend  
G2R-@-@@@@-@@  
— — — — — —  
1
2 3 4 5 6 7  
1. Relay Function  
4. Contact Type  
6. Terminal Shape  
7. Classification  
G
2
R
None: Single-side stable  
None: Single  
None: PCB terminals  
None: Standard  
K
: Double-winding latching  
Z
: Bifurcated contact  
T
: Quick-connect  
(upper bracket  
mounting #187)  
E
H
U
: High-capacity  
: High-sensitivity  
: For ultrasonically  
cleanable  
2. Number of poles  
1: 1-pole  
5. Enclosure rating  
None: Flux protection  
2: 2-pole  
(T-type is an enclosed  
Z
: Full-wave rectifier  
relay)  
3. Contact Form  
4
: Fully sealed  
None: NO/NC  
A
: NO  
Model Configuration  
Number of poles  
1-pole  
2-pole  
Minimum  
Classification  
Terminal  
Shape  
packing  
unit  
Enclosure  
rating  
Contact  
form  
SPST-NO (1a)  
G2R-1A  
SPDT (1c)  
G2R-1  
DPST-NO (2a)  
G2R-2A  
DPDT (2c)  
G2R-2  
AC  
DC  
AC  
DC  
Flux protection  
100  
pcs/tray  
Standard  
Fully sealed  
G2R-1A4  
G2R-14  
G2R-2A4  
G2R-24  
Flux protection  
Fully sealed  
G2R-1AZ  
G2R-1Z  
Bifurcated  
PCB terminals contact  
50  
pcs/tray  
DC  
G2R-1AZ4  
G2R-1Z4  
AC  
DC  
DC  
High-capacity  
Flux protection  
G2R-1A-E  
G2R-1-E  
100  
pcs/tray  
High-sensitivity  
Flux protection  
Flux protection  
G2R-1A-H  
G2RK-1A  
G2R-1-H  
G2RK-1  
G2R-2A-H  
G2RK-2A  
G2R-2-H  
G2RK-2  
Double-winding  
latching  
50  
pcs/tray  
DC  
AC  
DC  
100  
pcs/tray  
Quick-connect Standard  
Unsealed  
G2R-1A-T  
G2R-1-T  
Note 1. Full-wave rectifier and supersonic cleaner compatible models are also available. Refer to page 3.  
2.Sockets for PCB terminal models are not provided.  
1
G2R  
Ordering Information  
PCB Power Relay  
PCB Terminal Models  
Number of poles  
Contact form  
1-pole  
Rated coil voltage  
2-pole  
Classification  
Enclosure rating  
Model  
Model  
Rated coil voltage  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
NO  
G2R-1A  
G2R-2A  
Flux protection  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
NO/NC  
NO  
G2R-1  
G2R-2  
Standard  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
G2R-1A4  
G2R-14  
G2R-2A4  
G2R-24  
Fully sealed  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
NO/NC  
NO  
G2R-1A-H  
G2R-1-H  
G2RK-1A  
G2RK-1  
5, 6, 12, 24, 48 VDC  
5, 6, 12, 24, 48 VDC  
5, 6, 12, 24 VDC  
5, 6, 12, 24 VDC  
12, 24, 48 VDC  
100 VDC  
G2R-2A-H  
G2R-2-H  
G2RK-2A  
G2RK-2  
5, 6, 12, 24, 48 VDC  
5, 6, 12, 24, 48 VDC  
5, 12, 24 VDC  
G
2
R
High-sensitivity  
NO/NC  
NO  
Flux protection  
Flux protection  
Fully sealed  
Double-winding  
latching  
NO/NC  
5, 6, 12, 24 VDC  
NO  
G2R-1AZ  
G2R-1Z  
5, 6, 12, 24, 48 VDC  
100 VDC  
NO/NC  
NO  
Bifurcated  
contact  
5, 12, 24, 48 VDC  
100 VDC  
G2R-1AZ4  
G2R-1Z4  
5, 12, 24, 48 VDC  
100 VDC  
NO/NC  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
NO  
G2R-1A-E  
G2R-1-E  
High-capacity  
Flux protection  
12, 24, 100/(110) VAC  
200/(220) VAC  
5, 6, 12, 24, 48 VDC  
100 VDC  
NO/NC  
Note: When ordering, add the rated coil voltage to the model number.  
Example: G2R-1A AC12  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VAC.  
2
G2R  
Quick-connect Terminal (#187)  
PCB Power Relay  
Number of poles  
Contact form  
1-pole  
Rated coil voltage  
Classification  
Enclosure rating  
Model  
12, 24, 100/(110) VAC  
200/(220) VAC  
NO  
G2R-1A-T  
5, 6, 12, 24, 48 VDC  
100 VDC  
Standard  
Unsealed  
12, 24, 100/(110) VAC  
200/(220) VAC  
NO/NC  
G2R-1-T  
5, 6, 12, 24, 48 VDC  
100 VDC  
Full-wave Rectifier  
Number of poles  
Contact form  
1-pole  
2-pole  
Classification  
Enclosure rating  
Model  
Rated coil voltage  
5, 12, 24 VDC  
100 VDC  
Model  
Rated coil voltage  
5, 6, 12, 24, 48 VDC  
100 VDC  
NO  
G2R-1A-Z  
G2R-2A-Z  
Flux protection  
5, 12, 24, 48 VDC  
100 VDC  
12, 24, 48 VDC  
100 VDC  
NO/NC  
NO  
G2R-1-Z  
G2R-2-Z  
Standard  
5, 12, 48 VDC  
100 VDC  
24, 48 VDC  
G2R-1A4-Z  
G2R-14-Z  
G2R-2A4-Z  
G2R-24-Z  
100 VDC  
Fully sealed  
5, 12, 24, 48 VDC  
100 VDC  
5, 12, 24 VDC  
100 VDC  
G
2
NO/NC  
R
5, 12, 24 VDC  
100 VDC  
NO  
G2R-1A-EZ  
G2R-1-EZ  
High-capacity  
Flux protection  
NO/NC  
12, 24, 48 VDC  
For Ultrasonically Cleanable  
Number of poles  
Contact form  
1-pole  
2-pole  
Classification  
Enclosure rating  
Model  
Rated coil voltage  
12, 24, 100/(110) VAC  
200/(220) VAC  
Model  
Rated coil voltage  
100/(110) VAC  
NO  
G2R-1A4-U  
G2R-2A4-U  
5, 6, 12, 24, 48 VDC  
5, 12, 24 VDC  
Standard  
Fully sealed  
100/(110) VAC  
200/(220) VAC  
24, 100/(110) VAC  
200/(220) VAC  
NO/NC  
G2R-14-U  
G2R-24-U  
5, 12, 24, 48 VDC  
100 VDC  
5, 12, 24, 48 VDC  
100 VDC  
Note: When ordering, add the rated coil voltage to the model number.  
Example: G2R-1A-T AC12  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VAC.  
3
G2R  
Ratings  
PCB Power Relay  
Coil  
Must operate  
voltage (V)  
Must release  
voltage (V)  
Max. voltage  
(V)  
Power  
consumption  
(VA, W)  
Item Rated current (mA)  
Coil resistance  
(Ω)  
Classification  
Rated voltage  
12 VAC  
50 Hz  
93  
60 Hz  
75  
% of rated voltage  
65  
260  
• Standard  
24 VAC  
46.5  
11  
37.5  
• Quick-connect  
• Fully sealed  
• High-capacity  
140%  
(at 23°C)  
Approx. 0.9  
(60 Hz)  
80% max.  
70% max.  
30% min.  
100/(110) VAC  
200/(220) VAC  
5 VDC  
9/(10.6)  
4.5/(5.3)  
4,600  
20,200  
47  
5.5  
106  
88.2  
6 VDC  
68  
• Standard  
• High-capacity  
• Bifurcated contact  
• Quick-connect  
• Fully sealed  
12 VDC  
43.6  
21.8  
11.5  
5.3  
275  
170%  
(at 23°C)  
15% min.  
Approx. 0.53  
24 VDC  
1,100  
4,170  
18,870  
70  
48 VDC  
100 VDC  
5 VDC  
71.4  
60  
6 VDC  
100  
170%  
(at 23°C)  
• High-sensitivity  
12 VDC  
30  
400  
70% max.  
15% min.  
Approx. 0.36  
24 VDC  
15  
1,600  
6,400  
48 VDC  
7.5  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of+15%/-20% (AC rated current) or ±10% (DC coil resistance).  
2.AC coil resistances shown above are only reference values.  
G
2
R
3.The operating characteristics are measured at a coil temperature of 23°C.  
4.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
Coil: Double-winding Latching Relays  
Must set  
voltage (V) voltage (V)  
Must reset Max. voltage  
Item  
Set Coil  
Reset coil  
Power consumption  
(V)  
Rated current  
Coil resistance  
Rated current  
Coil resistance  
Set Coil  
(mW)  
Reset coil  
(mW)  
% of rated voltage  
Rated voltage  
5 VDC  
(mA)  
(Ω)  
(mA)  
119  
100  
50  
(Ω)  
42  
60  
167  
30  
43.5  
170  
694  
6 VDC  
138  
140%  
(at 23°C)  
Approx.  
850  
Approx.  
600  
70% max.  
70% max.  
12 VDC  
24 VDC  
70.6  
34.6  
240  
960  
25  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
2.The operating characteristics are measured at a coil temperature of 23°C.  
3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
4
G2R  
Contacts: Fully Protection Type  
PCB Power Relay  
Standard type  
Classification  
High-capacity type  
Bifurcated contact type  
High-sensitivity type  
Quick-connect Terminal (1single-pole type)  
Number of poles  
1-pole  
Inductive  
load  
2-pole  
Inductive  
load  
1-pole  
2-pole  
1-pole  
2-pole  
Inductive  
load  
Inductive  
Inductive  
Inductive  
load  
Resistive  
load  
Resistive  
load  
Resistive  
load  
load  
Resistive  
load  
load  
Resistive  
load  
Resistive  
load  
Load  
(cos  
L/R = 7 ms)  
φ
= 0.4;  
(cos  
L/R = 7 ms)  
φ
= 0.4;  
(cos  
φ
= 0.4;  
(cos  
φ
= 0.4;  
(cos  
L/R = 7 ms)  
Single  
φ
= 0.4;  
(cos  
φ
= 0.4;  
Item  
L/R = 7 ms)  
L/R = 7 ms)  
L/R = 7 ms)  
Contact type  
Single  
Single  
Bifurcated  
Ag-alloy (Cd free)  
8 A at 250 5 A at 250 2 A at 250 5 A at 250 2 A at 250 3 A at 250 1 A at 250  
Contact material  
10 A at  
7.5 A at  
5 A at 250 2 A at 250 16 A at  
250 VAC  
10 A at 30 5 A at 30  
VDC VDC  
250 VAC  
VAC  
5 A at 30  
VDC  
VAC  
3 A at 30  
VDC  
250 VAC  
16 A at 30 8 A at 30  
VDC VDC  
VAC  
VAC  
5 A at 30  
VDC  
VAC  
3 A at 30  
VDC  
VAC  
5 A at 30  
VDC  
VAC  
3 A at 30  
VDC  
VAC  
3 A at 30  
VDC  
VAC  
1.5 A at  
30 VDC  
Rated load  
Rated carry current  
10 A  
5 A  
16 A  
5 A  
5 A  
3 A  
Max. switching voltage  
Max. switching current  
380 VAC, 125 VDC  
380 VAC, 125 VDC  
380 VAC, 125 VDC  
10 A  
5 A  
16 A  
5 A  
5 A  
3 A  
Failure rate (P level)  
(reference value) *  
100 mA at 5 VDC  
10 mA at 5 VDC  
100 mA at 5 VDC  
1 mA at 5 VDC  
100 mA at 5 VDC  
10 mA at 5 VDC  
* This value was measured at a switching frequency of 120 operations/min.  
Contacts: Flux Sealed Type  
Classification  
Standard type (Single contact type)  
Bifurcated contact type  
1-pole  
Number of poles  
1-pole  
(cos  
2-pole  
Resistive load  
(cos = 1)  
Inductive load  
= 0.4; L/R = 7 ms)  
Resistive load  
(cos = 1)  
Inductive load  
Resistive load  
(cos = 1)  
Inductive load  
Load  
Item  
φ
φ
φ
(cos  
Single  
Ag-alloy (Cd free)  
φ
= 0.4; L/R = 7 ms)  
φ
(cos  
φ
= 0.4; L/R = 7 ms)  
Contact type  
Single  
Bifurcated  
G
2
R
Contact material  
8 A at 250 VAC  
8 A at 30 VDC  
6 A at 250 VAC  
4 A at 30 VDC  
4 A at 250 VAC  
4 A at 30 VDC  
1.5 A at 250 VAC  
2.5 A at 30 VDC  
5 A at 250 VAC  
5 A at 30 VDC  
2 A at 250 VAC  
3 A at 30 VDC  
Rated load  
Rated carry current  
8 A  
4 A  
5 A  
Max. switching voltage  
Max. switching current  
380 VAC, 125 VDC  
8 A  
380 VAC, 125 VDC  
4 A  
380 VAC, 125 VDC  
5 A  
Failure rate (P level)  
(reference value) *  
100 mA at 5 VDC  
10 mA at 5 VDC  
1 mA at 5 VDC  
* This value was measured at a switching frequency of 120 operations/min.  
Contacts: Latching Type  
Number of poles  
1-pole  
(cos  
2-pole  
(cos  
Resistive load  
(cos = 1)  
Inductive load  
= 0.4; L/R = 7 ms)  
Resistive load  
(cos = 1)  
Inductive load  
φ = 0.4; L/R = 7 ms)  
Load  
Item  
φ
φ
φ
Contact type  
Single  
Single  
Contact material  
Ag-alloy (Cd free)  
5 A at 250 VAC  
5 A at 30 VDC  
3.5 A at 250 VAC  
2.5 A at 30 VDC  
3 A at 250 VAC  
3 A at 30 VDC  
1.5 A at 250 VAC  
2 A at 30 VDC  
Rated load  
Rated carry current  
5 A  
3 A  
Max. switching voltage  
Max. switching current  
380 VAC, 125 VDC  
5 A  
380 VAC, 125 VDC  
3 A  
Failure rate (P level)  
(reference value) *  
100 mA at 5 VDC  
10 mA at 5 VDC  
* This value was measured at a switching frequency of 120 operations/min.  
5
G2R  
Characteristics  
PCB Power Relay  
Standard Relays  
Double-winding Latching Relays  
Item  
Number of poles  
1-pole  
30 mΩ max.  
2-pole  
50 mΩ max.  
Item  
Number of poles  
1-pole  
30 mΩ max.  
2-pole  
50 mΩ max.  
Contact resistance *1  
Contact resistance *1  
Operate time *2  
Release time *2  
Max.  
operating  
frequency  
Time *2  
Min. set pulse width *3  
Time *2  
Min. reset pulse  
width *3  
20 ms max.  
30 ms  
20 ms max.  
15 ms max.  
Set  
AC: 10 ms max.; DC: 5 ms max.  
18,000 operations/hr  
Mechanical  
Reset  
30 ms  
Electrical  
1,800 operations/hr  
1,000 MΩ min.  
Max.operating Mechanical  
frequency Electrical  
Insulation resistance *4  
Between coil and  
18,000 operations/hr  
1,800 operations/hr  
1,000 MΩ min.  
Insulation resistance *3  
Between coil and  
5,000 VAC, 50/60 Hz for 1 min  
contacts  
Between contacts  
of different polarity  
Between contacts  
of the same  
5,000 VAC, 50/60 Hz for 1 min  
3,000 VAC, 50/60 Hz  
for 1 min  
Dielectric  
strength  
contacts  
-
Between contacts of  
different polarity  
Between contacts of  
the same polarity  
Between set and  
reset coils  
3,000 VAC,  
50/60 Hz for 1 min  
Dielectric  
strength  
1,000 VAC, 50/60 Hz for 1 min  
1,000 VAC, 50/60 Hz for 1 min  
1,000 VAC, 50/60 Hz for 1 min  
Clearance: 8 mm, Creepage: 8 mm  
polarity  
Insulation Between coil and  
distance  
Clearance: 8 mm, Creepage: 8 mm  
contacts  
10 to 55 to 10 Hz, 0.75 mm single  
amplitude (1.5 mm double amplitude)  
10 to 55 to 10 Hz, 0.75 mm single  
amplitude (1.5 mm double amplitude)  
1,000 m/s2  
Insulation  
distance  
Between coil and  
contacts  
Destruction  
Vibration  
resistance  
10 to 55 to 10 Hz, 0.75 mm single  
amplitude (1.5 mm double amplitude)  
10 to 55 to 10 Hz, 0.75 mm single  
amplitude (1.5 mm double amplitude)  
1,000 m/s2  
Malfunction  
Destruction  
Malfunction  
Destruction  
Vibration  
resistance  
Shock  
resistance  
Malfunction  
Destruction  
Malfunction  
200 m/s2 when energized;  
100m/s2 when no energized  
AC coil: 10,000,000 operations min.;  
DC coil: 20,000,000 operations min.  
(at 18,000 operations/hr)  
Shock  
resistance  
Set: 500m/s2 Armature OFF  
Reset: 200m/s2 Contact OFF  
10,000,000 operations min  
(at 18,000 operations/hr)  
100,000 operations min. (at 1,800  
operations/hr under rated load)  
-40°C to 70°C (with no icing or  
condensation)  
Mechanical  
Electrical  
Durability  
Mechanical  
Electrical  
100,000 operations min.  
Durability  
(at 1,800 operations/hr under rated load)  
-40°C to 70°C (with no icing)  
5% to 85%  
G
2
R
Ambient operating temperature  
Ambient operating humidity  
Weight  
Ambient operating temperature  
Approx. 17 g (Approx. 20 g *4)  
Ambient operating humidity  
Weight  
5% to 85%  
Approx. 17 g  
Note: The values here are initial values.  
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.  
*2. Measurement conditions: Rated operating voltage applied, not including  
contact bounce.  
Note: The values here are initial values.  
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.  
*2. Measurement conditions: Rated operating voltage applied, not including  
contact bounce.  
*3. Measurement conditions: The insulation resistance was measured with a  
500 VDC megohmmeter at the same locations as the dielectric strength  
was measured.  
*3. Measurement couditions: Rated operating voltage applied.  
*4. Measurement conditions: The insulation resistance was measured with a  
500 VDC megohmmeter at the same locations as the dielectric strength  
was measured.  
*4. Value for quick-connect terminals.  
Engineering Data  
Maximum Switching Capacity  
Flux Protection/Plug-in Relays  
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T  
G2R-1-E, G2R-1A-E  
G2R-1Z, G2R-1AZ  
50  
50  
50  
AC resistive load  
16  
10  
AC resistive load  
10  
10  
AC resistive load  
AC  
5
5
5
AC  
DC resistive load  
inductive load  
(cosφ = 0.4)  
inductive load  
(cosφ = 0.4)  
DC resistive load  
AC  
inductive load  
(cosφ = 0.4)  
DC inductive load  
(L/R = 7 ms)  
DC resistive load  
DC inductive load  
(L/R = 7 ms)  
1
1
1
DC inductive load  
(L/R = 7 ms)  
0.5  
0.5  
0.1  
0.5  
0.1  
0.1  
0
5
10 20 30 50 100  
500  
0
5
10 20 30 50 100  
500  
0
5
10 20 30 50 100  
500  
Switching voltage (V)  
Switching voltage (V)  
Switching voltage (V)  
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A  
G2R-2-H, G2R-2A-H  
50  
50  
10  
10  
5
AC resistive load  
AC resistive load  
5
AC  
inductive load  
(cosφ = 0.4)  
DC resistive load  
AC  
DC resistive load  
1
1
inductive load  
(cosφ = 0.4)  
DC inductive load  
(L/R = 7 ms)  
0.5  
0.5  
DC inductive load  
(L/R = 7 ms)  
0.1  
0.1  
0
5
10 20 30 50 100  
500  
0
5
10 20 30 50 100  
500  
Switching voltage (V)  
Switching voltage (V)  
6
G2R  
G2RK-1A, G2RK-1  
PCB Power Relay  
G2RK-2A, G2RK-2  
50  
50  
10  
5
10  
AC resistive load  
5
3
AC resistive load  
AC  
inductive load  
(cosφ = 0.4)  
DC resistive load  
1
AC  
DC resistive load  
1
inductive load  
(cosφ = 0.4)  
0.5  
0.5  
DC inductive load  
DC inductive load  
(L/R = 7 ms)  
(L/R = 7 ms)  
0.1  
0.1  
0
5
10 20 30 50 100  
500  
0
5
10 20 30 50 100  
500  
Switching voltage (V)  
Switching voltage (V)  
Fully Sealed Relays  
G2R-14, G2R-1A4  
50  
G2R-24, G2R-2A4  
G2R-1Z4, G2R-1AZ4  
50  
50  
AC resistive load  
10  
5
10  
5
10  
5
AC resistive load  
AC resistive load  
AC  
inductive load  
(cosφ = 0.4)  
DC resistive load  
G
2
R
DC resistive load  
1
AC  
DC resistive load  
AC  
inductive load  
1
1
inductive load  
(cosφ = 0.4)  
(cosφ = 0.4)  
DC inductive load  
(L/R = 7 ms)  
DC inductive load  
(L/R = 7 ms)  
0.5  
0.5  
0.5  
DC inductive load  
(L/R = 7 ms)  
0.1  
0.1  
0.1  
0
5
10 20 30 50 100  
300 500  
0
5
10 20 30 50 100  
300 500  
0
5
10 20 30 50 100  
300 500  
Switching voltage (V)  
Switching voltage (V)  
Switching voltage (V)  
Durability  
Flux Protection/Plug-in Relays  
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T  
G2R-1-E, G2R-1A-E  
G2R-1Z, G2R-1AZ  
1,000  
1,000  
1,000  
500  
500  
500  
250 VAC/30 VDC  
resistive load  
300  
300  
300  
250 VAC/30 VDC  
resistive load  
100  
100  
100  
250 VAC inductive load  
(cosφ = 0.4)  
30 VDC inductive load (L/R = 7ms)  
50  
50  
30  
50  
30  
250 VAC/30 VDC  
resistive load  
30  
10  
10  
10  
250 VAC inductive load (cosφ = 0.4)  
30 VDC inductive load (L/R = 7ms)  
250 VAC inductive load  
(cosφ = 0.4)  
30 VDC inductive load (L/R = 7ms)  
5
3
5
3
5
3
0
0
0
2
4
5
6
7.5 8  
10  
12  
14  
2
4
6
8
10  
12  
14  
16 18  
1
2
3
4
5
6
Switching current (A)  
Switching current (A)  
Switching current (A)  
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A  
G2R-2-H, G2R-2A-H  
1,000  
1,000  
500  
500  
300  
300  
250 VAC/30 VDC  
resistive load  
100  
100  
30 VDC inductive load  
(L/R = 7ms)  
30 VDC inductive load (L/R = 7ms)  
50  
50  
30  
250 VAC/30 VDC  
resistive load  
30  
10  
10  
250 VAC inductive load  
(cosφ = 0.4)  
250 VAC inductive load  
(cosφ = 0.4)  
5
3
5
3
0
0
1
2
3
4
5
6
1
1.5  
2
3
4
Switching current (A)  
Switching current (A)  
7
G2R  
G2RK-1A, G2RK-1  
PCB Power Relay  
G2RK-2A, G2RK-2  
1,000  
1,000  
500  
500  
300  
300  
250 VAC/30 VDC  
resistive load  
100  
100  
30 VDC inductive load  
(L/R = 7ms)  
250 VAC/30 VDC  
resistive load  
50  
30  
50  
30  
250 VAC inductive load  
(cosφ = 0.4)  
250 VAC inductive load  
(cosφ = 0.4)  
10  
5
10  
5
3
30 VDC inductive load (L/R = 7ms)  
3
0
0
1
2
2.5  
3
3.5  
4
5
6
1
1.5  
2
2.5  
3
4
Switching current (A)  
Switching current (A)  
Fully Sealed Relays  
G2R-14, G2R-1A4  
G2R-24, G2R-2A4  
G2R-1Z4, G2R-1AZ4  
1,000  
1,000  
1,000  
500  
500  
500  
300  
300  
300  
30 VDC inductive load (L/R = 7ms)  
250 VAC/30 VDC  
resistive load  
30 VDC inductive load (L/R = 7ms)  
100  
100  
100  
250 VAC inductive load  
(cosφ = 0.4)  
250 VAC/30 VDC  
resistive load  
50  
30  
50  
30  
50  
30  
250 VAC/30 VDC  
resistive load  
G
2
R
10  
10  
10  
250 VAC inductive load  
(cosφ = 0.4)  
250 VAC inductive load  
(cosφ = 0.4)  
30 VDC inductive load (L/R = 7ms)  
5
3
5
3
5
3
0
0
0
2
4
6
8
10  
12  
1
1.5  
2
2.5  
3
4
5
6
1
2
3
4
5
6
Switching current (A)  
Switching current (A)  
Switching current (A)  
Ambient Temperature vs. Maximum  
Coil Voltage  
Ambient Temperature vs. Must  
Operate and Must Release Voltage  
G2R-1  
G2R-2  
250  
200  
100  
100  
Must operate voltage  
Must release voltage  
Must operate voltage  
Must release voltage  
Sample: G2R-1  
Number of Relays: 5 pcs  
Sample: G2R-2  
Number of Relays: 5 pcs  
80  
60  
40  
80  
60  
40  
max.  
X
max.  
X
DC coil  
170  
150  
140  
min.  
min.  
110  
100  
max.  
X
max.  
X
AC coil  
min.  
50  
20  
0
20  
0
min.  
0
25 20  
30  
40  
50  
60 70  
80  
90 100  
60  
40  
20  
0
20  
40  
60  
80  
60  
40  
20  
0
20  
40  
60  
80  
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Note: The maximum coil voltage refers to the maximum  
value in a varying range of operating power voltage,  
not a continuous voltage.  
Shock Malfunction  
Keep-power decrement with time  
G2R-1 Number of Relays: 5 pcs  
G2R-2 Number of Relays: 5 pcs  
G2RK-1  
Y
Y
Test Conditions:  
Shock is applied in  
±X, ±Y, and ±Z  
directions three times  
each with and without  
energizingtheRelays  
to check the number  
of contact  
Test Conditions:  
Shock is applied in  
±X, ±Y, and ±Z  
directionsthreetimes  
eachwithandwithout  
energizing the  
Relays to check the  
number of contact  
malfunctions.  
Requirement:  
200 m/s2 when  
energized; 100m/s2  
when de-energized  
Shock direction  
160  
SPST-NO (1a)  
SPST-NC (1c)  
1,000  
1,000  
Number of Relays: 50 pcs  
SPST-NO (1a)  
SPST-NC (1c)  
Measurement: after the relay kept static by  
applying a rated voltage, leave the relay at room  
temperature of 20°C to 30°C, and high temperature  
of 80°C 2°C respectively, to measure how the  
140  
800  
600  
400  
200  
800  
600  
400  
200  
X
X
Z'  
Z'  
120 keep-power varies with time.  
MAX  
Room  
temperature  
)
MIN  
100  
80  
malfunctions.  
270  
200  
Requirement:  
200 m/s2 when  
MAX  
High  
temperature  
200  
400  
600  
800  
)
MIN  
energized; 100m/s2  
when de-energized  
400  
600  
800  
60  
Z
X'  
Z
X'  
Shock direction  
40  
X
X'  
X
X'  
Y
Y
20  
Z
1,000  
1,000  
Z
Unit: m/s2  
Unit: m/s2  
Y'  
Y'  
Z'  
Z'  
0
50 100  
500 1,000  
5,000 10,000  
Y'  
Y'  
Elapsed time (H)  
8
G2R  
Dimensions  
PCB Power Relay  
Relays with PCB Terminals  
(SPDT (1c) Relays)  
G2R-1(-Z)  
G2R-1Z  
G2R-1-H  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
3.5 3.5  
(2.7)  
1
2
3
25.5 max.  
(25.3)*  
7.5  
Five, 1.3-dia.  
holes  
(0.3)  
5
4
(2.1)  
20  
(No coil polarity)  
0.5  
0.5**  
** Average value  
1
4
0.3  
This illustration is the  
G2R-1 model.  
0.16  
** With AC coil or “-H” models: 0.3.  
Relays with PCB Terminals  
(SPST-NO (1a) Relays)  
G2R-1A(-Z)  
G2R-1AZ  
G2R-1A-H  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
3.5  
(2.7)  
1
3
25.5 max.  
(25.3)*  
7.5  
Four, 1.3-dia.  
holes  
(0.3)  
G
2
R
5
4
(2.1)  
20  
(No coil polarity)  
0.3  
0.5**  
1
4
0.16  
** Average value  
** With AC coil or “-H” models: 0.3.  
This illustration is the  
G2R-1A model.  
Relays with PCB Terminals  
(SPDT (1c) /High-capacity Relays)  
G2R-1-E(Z)  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
13 max.  
(12.6)*  
29 max.  
(28.6)*  
Eight, 1.3-dia. holes  
2.5  
2.5  
(2.7)  
7.5  
1
2
7
3
6
4
5
25.5 max.  
(24.9)*  
(0.3)  
8
(No coil polarity)  
0.5  
0.3  
1
4
(2.1)  
5
5
(2.1)  
0.3  
* Average value  
20  
0.16  
Relays with PCB Terminals  
(SPST-NO (1a)/High-capacity Relays)  
G2R-1A-E(Z)  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
13 max.  
(12.6)*  
29 max.  
(28.6)*  
2.5  
Six, 1.3-dia. holes  
2.5  
(2.7)  
7.5  
1
3
4
5
25.5 max.  
(24.9)*  
(0.3)  
8
6
(No coil polarity)  
0.3  
* Average value  
1
4
(2.1)  
20  
5
(2.1)  
0.3  
0.16  
Note: Orientation marks are indicated as follows:  
9
G2R  
PCB Power Relay  
Relays with PCB Terminals  
(SPDT (1c) Relays)  
G2R-14(-Z)(-U)  
13.5 max.  
(12.9)*  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
3.5 3.5  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
29 max.  
(28.6)*  
G2R-1Z4  
25.5 max.  
(24.8)*  
(2.7)  
1
2
3
7.5  
Five, 1.3-dia.  
holes  
5
4
0.5  
0.5  
1
(2.1)  
20  
4
(No coil polarity)  
0.3  
* Average value  
0.16  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
Relays with PCB Terminals  
13.5 max.  
(12.9)*  
29 max.  
(28.6)*  
(SPST-NO (1a) Relays)  
G2R-1A4(-Z)(-U)  
G2R-1AZ4  
3.5  
25.5 max.  
(24.8)*  
(2.7)  
1
3
7.5  
Four, 1.3-dia.  
holes  
5
4
0.5  
1
4
(2.1)  
20  
(No coil polarity)  
0.3  
* Average value  
0.16  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
3.5 3.5  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
Double-winding Latching Relays with  
13 max.  
(12.8)*  
29 max.  
(28.8)*  
PCB Terminals  
(SPDT (1c) Relays)  
G2RK-1  
G
2
R
1
2
3
4
(2.7)  
25.5 max.  
(25.2)*  
-
-
S
R
+
+
7.5  
(0.3)  
Seven, 1.3-dia.  
holes  
7
6
5
(After confirming coil  
polarity, wire correctly.)  
0.5  
5
0.3  
0.5  
0.16  
1
4
(2.1)  
20  
1
* Average value  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
3.5  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
13 max.  
(12.8)*  
Double-winding Latching Relays with  
29 max.  
(28.8)*  
PCB Terminals  
(SPST-NO (1a) Relays)  
G2RK-1A  
1
2
4
+
25.5 max.  
(25.2)*  
(2.7)  
S
R
+
7.5  
7
6
5
(0.3)  
Six, 1.3-dia.  
holes  
(After confirming coil  
polarity, wire correctly.)  
1
0.3  
0.5  
0.16  
5
4
(2.1)  
20  
1
* Average value  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
2.5  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
Double-winding Latching Relays with PCB Terminals  
(DPDT (2c) Relays)  
13 max.  
G2RK-2  
(12.8)*  
29 max.  
(28.8)*  
Ten, 1.3-dia. holes  
2.5  
1
2
3
8
4
7
5
6
-
-
(2.7)  
7.5  
S
+
10  
R
25.5 max.  
(25.3)*  
+
9
(0.3)  
(2.7)  
(After confirming coil  
polarity, wire correctly.)  
0.5  
0.15  
1
4
0.3  
0.5  
1
(2.1)  
5
5
5
(2.1)  
* Average value  
20  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
2.5  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
Double-winding Latching Relays with PCB Terminals  
(DPST-NO (2a) Relays)  
13 max.  
(12.8)*  
G2RK-2A  
29 max.  
(28.8)*  
Eight, 1.3-dia. holes  
2.5  
1
2
4
5
-
-
(2.7)  
7.5  
S
R
25.5 max.  
(25.3)*  
+
+
10  
9
7
6
(0.3)  
(2.7)  
(After confirming coil  
polarity, wire correctly.)  
0.3  
1
0.5  
0.15  
1
4
5
5
(2.1)  
(2.1)  
* Average value  
20  
Note: Orientation marks are indicated as follows:  
10  
G2R  
PCB Power Relay  
Relays with PCB Terminals  
(DPDT (2c) Relays)  
G2R-2(-Z)  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
G2R-2-H  
Eight, 1.3-dia. holes  
2.5  
2.5  
(2.7)  
7.5  
1
2
7
3
6
4
5
25.5 max.  
(25.2)*  
(0.3)  
8
(No coil polarity)  
0.5  
0.5  
1
4
0.3  
(2.1)  
5
5
(2.1)  
0.15  
* Average value  
20  
Relays with PCB Terminals  
(DPST-NO (2a) Relays)  
G2R-2A  
G2R-2A-H  
G2R-2A-Z  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
Six, 1.3-dia. holes  
2.5  
2.5  
(2.7)  
7.5  
1
3
4
5
25.5 max.  
(25.2)*  
(0.3)  
8
6
(No coil polarity)  
0.5  
1
4
G
2
R
0.3  
(2.1)  
20  
5
(2.1)  
0.15  
* Average value  
Relays with PCB Terminals  
(DPDT (2c) Relays)  
G2R-24(-Z)(-U)  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
13.5 max.  
(12.8)*  
29 max.  
(28.6)*  
Eight, 1.3-dia. holes  
2.5  
2.5  
(2.7)  
7.5  
1
2
7
3
6
4
5
25.5 max.  
(24.7)*  
8
(No coil polarity)  
0.5  
0.5  
1
4
(2.1)  
5
5
(2.1)  
* Average value  
0.15  
20  
Relays with PCB Terminals  
(DPST-NO (2a) Relays)  
G2R-2A4(-Z)(-U)  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
13.5 max.  
(12.8)*  
29 max.  
(28.6)*  
Six, 1.3-dia. holes  
2.5  
2.5  
(2.7)  
7.5  
1
3
4
5
25.5 max.  
8
6
(No coil polarity)  
0.5  
* Average value  
1
4
0.3  
(2.1)  
20  
5
(2.1)  
0.15  
Note: Orientation marks are indicated as follows:  
11  
G2R  
Relays with Quick-connect  
Terminals  
PCB Power Relay  
30.5 max.  
(29.7)*  
(SPDT (1c) Relays)  
G2R-1-T  
7.5  
Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
5.2  
5.2  
17.5  
* Average value  
Five, 1.3-dia. holes  
Two M3 or  
two 3.5 dia.  
4.75  
0.5  
38  
1
8.5  
2
4
3
5
29.5 max.  
(No coil polarity)  
Note: Model number of  
quick-connect terminal is 187.  
45 max.  
(43.9)*  
14 max.  
(13.1)*  
2.5  
Relays with Quick-connect  
Terminals  
30.5 max.  
(29.7)*  
(SPST-NO (1a) Relays)  
G2R-1A-T  
7.5  
Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
5.2  
17.4  
* Average value  
G
2
R
Two M3 or  
two 3.5 dia.  
Four, 1.3-dia. holes  
38  
4.75  
0.5  
1
4
3
8.5  
5
(No coil polarity)  
29.5 max.  
Note: Model number of  
quick-connect terminal is 187.  
45 max.  
(43.9)*  
14 max.  
(13.1)*  
2.5  
Note: Orientation marks are indicated as follows:  
12  
G2R  
Approved Standards  
PCB Power Relay  
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the  
values before use.  
UL Recognized:  
1-pole  
File No. E41643  
CSA Certified:  
1-pole  
File No. LR31928  
Number of  
test  
operations  
Number of  
test  
operations  
Contact  
form  
Contact  
form  
Model  
Coil ratings  
Contact ratings  
Model  
Coil ratings  
Contact ratings  
G2R-1A  
G2R-1A  
10 A, 250 VAC (General  
Use) at 40°C  
100,000  
6,000  
10 A, 250 VAC (General  
Use) at 40°C  
G2R-1A4  
G2R-1A-H  
G2R-1A-T  
G2R-1  
100,000  
SPST-NO  
(1a)  
G2R-1A4  
SPST-NO  
(1a)  
5 A, 277 VAC (General  
Use) at 40°C  
G2R-1A-H  
G2R-1A-T  
5 to 110 VDC  
12 to 220 VAC  
10 A, 30 VDC  
(Resistive) at 40°C  
5 to 110 VDC  
12 to 220 VAC  
100,000  
25,000  
G2R-14  
5 A, 30 VDC (Resistive)  
at 40°C  
SPDT  
(1c)  
100,000  
25,000  
G2R-1  
G2R-1-H  
G2R-1-T  
G2R-1AZ  
G2R-1AZ4  
G2R-1Z  
TV-3 (N. O. only) at  
40°C  
G2R-14  
SPDT  
(1c)  
G2R-1-H  
G2R-1-T  
G2R-1AZ  
G2R-1AZ4  
G2R-1Z  
G2R-1Z4  
TV-3 (N. O. only) at  
40°C  
SPST-NO  
(1a)  
5 A, 250 VAC (General  
Use) at 40°C  
5 to 110 VDC  
12 to 220 VAC  
6,000  
SPST-NO  
(1a)  
10 A, 250 VAC (General  
Use) at 40°C  
SPDT  
(1c)  
5 A, 30 VDC (Resistive)  
at 40°C  
5 to 110 VDC  
12 to 220 VAC  
6,000  
G2R-1Z4  
SPDT  
(1c)  
5 A, 30 VDC (Resistive)  
at 40°C  
16 A, 250 VAC (General  
Use) at 40°C  
5 to 110 VDC 16 A, 30 VDC  
12 to 220 VAC (Resistive) at 40°C  
TV-3 (N. O. only) at  
SPST-NO  
(1a)  
G2R-1A-E  
G2R-1-E  
6,000  
SPST-NO  
(1a)  
16 A, 250 VAC (General  
Use) at 40°C  
5 to 110 VDC 16 A, 30 VDC  
12 to 220 VAC (Resistive) at 40°C  
TV-3 (N. O. only) at  
G2R-1A-E  
30,000  
6,000  
G
2
R
SPDT  
(1c)  
25,000  
40°C  
SPDT  
(1c)  
G2R-1-E  
25,000  
2-pole  
40°C  
Number of  
test  
operations  
Contact  
form  
2-pole  
Model  
Coil ratings  
Contact ratings  
Number of  
test  
operations  
Contact  
form  
Model  
Coil ratings  
Contact ratings  
G2R-2A  
G2R-2A4  
G2R-2A-H  
G2R-2  
5 A, 250 VAC (General  
Use) at 40°C  
6,000  
100,000  
25,000  
DPST-NO  
(2a)  
G2R-2A  
G2R-2A4  
G2R-2A-H  
G2R-2  
5 A, 250 VAC (General  
Use) at 40°C  
6,000  
100,000  
25,000  
DPST-NO  
(2a)  
5 to 110 VDC 5 A, 30 VDC (Resistive)  
12 to 220 VAC at 40°C  
5 to 110 VDC 5 A, 30 VDC (Resistive)  
12 to 220 VAC at 40°C  
DPDT  
(2c)  
G2R-24  
TV-3 (N. O. only) at  
40°C  
G2R-24-H  
DPDT  
(2c)  
G2R-24  
TV-3 (N. O. only) at  
40°C  
G2R-24-H  
EN/IEC, VDE Certified: Certificate No. 40015012  
Number of  
test  
operations  
Contact  
form  
Model  
Coil ratings  
Contact ratings  
5, 6, 12, 24,  
48, 100 VDC  
12, 24,  
16 A, 250 VAC  
(cos = 1.0) at 70°C  
G2R-1(A)-E  
1
φ
100/110,  
200/220 VAC  
5, 6, 12, 24, 10 A, 250 VAC  
48, 100 VDC (cos  
12, 24,  
100/110,  
φ = 1.0) at 40°C  
1
2
100,000  
10 A, 30 VDC (0 ms) at  
40°C  
200/220 VAC  
G2R-(  
)
5, 6, 12, 24, 5 A, 250 VAC  
48, 100 VDC (cos  
12, 24,  
φ = 1.0) at 40°C  
5 A, 30 VDC (0 ms) at  
40°C  
100/110,  
200/220 VAC  
EN, TÜV Certified: Registration No. R50030327  
Number of  
test  
operations  
Contact  
form  
Model  
Coil ratings  
Contact ratings  
5 to 110 VDC 16 A, 250 VAC  
12 to 220 VAC (cos = 1.0) at 70°C  
10 A, 250 VAC  
(cos = 1.0) at 70°C  
G2R-1(A)-E  
1
φ
φ
5 to 110 VDC  
12 to 220 VAC  
1
2
10 A, 30 VDC (0 ms) at  
70°C  
100,000  
G2R-(  
)
5 A, 250 VAC  
(cosφ = 1.0) at 40°C  
5 to 110 VDC  
12 to 220 VAC  
5 A, 30 VDC (0 ms) at  
40°C  
13  
G2R  
Precautions  
PCB Power Relay  
Please refer to “PCB Relays Common Precautions” for correct use.  
Correct Use  
Mounting  
Refer to the following table for  
examples of positive-lock connectors  
made by AMP. Contact the  
manufacturer directly for details on  
connectors including availability.  
Receptacle  
Therefore, do not use the Relay in a  
strong magnetic field environment.  
• When mounting a number of relays on  
a PCB, be sure to provide a minimum  
mounting space of 5 mm between the  
two juxtaposed relays as shown  
below.  
Degradation over Time of Double-  
winding Latching Relays Holding  
Ability  
• If a double-winding latching Relay is  
used left set for an extended period,  
changes over time will degrade the  
magnetic force, and the reduction in  
holding ability may cause the set  
status to be released. This is also  
because of the properties of semi-hard  
magnetic material, and the rate of  
degradation over time depends on the  
ambient environment (e.g.,  
Type  
Positive housing  
terminals  
AMP172074-1  
AMP170330-1 (natural color)  
(170324-1) AMP172074-4  
AMP170331-1 (yellow)  
(170325-1) AMP172074-5  
AMP170332-1 (green)  
(170326-1) AMP172074-6  
(blue)  
5 mm  
min.  
#187  
(Width  
4.75)  
5 mm min.  
Note: The numbers shown in parentheses are for  
air-feeding.  
Handling  
• The terminals are compatible with  
Faston receptacle #187 and are  
suitable for positive-lock mounting.  
Use only Faston terminals with the  
specified numbers.  
Minimum Pulse Width of Double-  
winding Latching Relays  
temperature, humidity, vibration, and  
presence or absence of external  
magnetic fields).Perform maintenance  
at least once a year by resetting,  
applying the rated voltage again, and  
then setting.  
• The minimum pulse width shown in  
the table of characteristics are values  
measured under conditions of ambient  
temperature at 23°C with rated  
operating voltage imposed on coil.  
The Relay may not provide a  
G
2
R
Select leads for connecting Faston  
receptacles with wire diameters that  
are within the allowable range for the  
load current.  
Wiring High Capacity (-E) Models  
• High-capacity models (-E) have a  
structure that connects two terminals  
from one contact.  
satisfactory performance as its holding  
ability decreases depending on the  
operating circuit conditions and  
ambient temperature, or decreases  
due to degradation over time.  
Do not apply excessive force to the  
terminals when mounting or  
dismounting the Faston receptacle.  
Also, do not insert terminals at an  
angle, or insert/remove multiple  
terminals at the same time. Be sure to  
insert and remove terminals carefully  
one at a time.  
When designing the circuit, use both  
terminals.  
If you use only one terminal, the relay  
may be unable to satisfy specified  
performance.  
In actual operation, impose to the coil  
a rated operating voltage with a pulse  
width that is suitable to the actual load,  
and reset the setting at least once a  
year, to correspond to the degradation  
over time.  
• When using the Relay in a strong  
magnetic field environment, the  
magnetic body may be demagnetized  
due to the influence of environment,  
causing the Relay to malfunction.  
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. K013-E1-17  
0316(0207)(O)  
14  

相关型号:

G2R-1-S

PCB Relay A Power Relay for a Variety of Purposes with Various Models
OMRON

G2R-1-S-100VDC

Power/Signal Relay, SPDT, Momentary, 0.005A (Coil), 100VDC (Coil), 530mW (Coil), 8A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G2R-1-S-110VAC

Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 8A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Through Hole-Straight Mount
OMRON

G2R-1-S-120VAC

Power/Signal Relay
OMRON

G2R-1-S-12VAC

Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 8A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Through Hole-Straight Mount
OMRON

G2R-1-S-24VAC

Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 8A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Through Hole-Straight Mount
OMRON

G2R-1-S-6VDC

Power/Signal Relay, SPDT, Momentary, 0.088A (Coil), 6VDC (Coil), 530mW (Coil), 8A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G2R-1-S-AC230(S)

Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 10A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

G2R-1-S-DC12

Color Rgistration Mark Incandescent
OMRON

G2R-1-S-DC12(S)

Power/Signal Relay, SPDT, Momentary, 0.043A (Coil), 12VDC (Coil), 530mW (Coil), 10A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

G2R-1-S-DC24(S)

Power/Signal Relay, SPDT, Momentary, 0.022A (Coil), 24VDC (Coil), 530mW (Coil), 10A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

G2R-1-SAC120(S)

POWER/SIGNAL RELAY, SPDT, MOMENTARY, 1250000mW (COIL), 10A (CONTACT), 30VDC (CONTACT), PANEL MOUNT, ROHS COMPLIANT
OMRON