G2R-1-TDC100
更新时间:2024-09-19 05:01:17
品牌:OMRON
描述:Electromechanical Relay, 1 Form A, SPST, Latched, 10A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output
G2R-1-TDC100 概述
Electromechanical Relay, 1 Form A, SPST, Latched, 10A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output
G2R-1-TDC100 数据手册
通过下载G2R-1-TDC100数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载G2R
PCB Power Relay
The Best Seller G2R
• 1General purpose power Relays of single-pole10 A and double-pole 5 A.
• Safety-oriented design with dielectric strength of 5,000 V between coil
and contacts, and surge resistance of 10,000 V.
• AC and DC types are both available for operational coils.
RoHS Compliant
■Model Number Legend
G2R-@-@@@@-@@
—
— — — — — —
1
2 3 4 5 6 7
1. Relay Function
4. Contact Type
6. Terminal Shape
7. Classification
G
2
R
None: Single-side stable
None: Single
None: PCB terminals
None: Standard
K
: Double-winding latching
Z
: Bifurcated contact
T
: Quick-connect
(upper bracket
mounting #187)
E
H
U
: High-capacity
: High-sensitivity
: For ultrasonically
cleanable
2. Number of poles
1: 1-pole
5. Enclosure rating
None: Flux protection
2: 2-pole
(T-type is an enclosed
Z
: Full-wave rectifier
relay)
3. Contact Form
4
: Fully sealed
None: NO/NC
A
: NO
■Model Configuration
Number of poles
1-pole
2-pole
Minimum
Classification
Terminal
Shape
packing
unit
Enclosure
rating
Contact
form
SPST-NO (1a)
G2R-1A
SPDT (1c)
G2R-1
DPST-NO (2a)
G2R-2A
DPDT (2c)
G2R-2
AC
DC
AC
DC
Flux protection
100
pcs/tray
Standard
Fully sealed
G2R-1A4
G2R-14
G2R-2A4
G2R-24
Flux protection
Fully sealed
G2R-1AZ
G2R-1Z
−
−
−
−
Bifurcated
PCB terminals contact
50
pcs/tray
DC
G2R-1AZ4
G2R-1Z4
AC
DC
DC
High-capacity
Flux protection
G2R-1A-E
G2R-1-E
−
−
100
pcs/tray
High-sensitivity
Flux protection
Flux protection
G2R-1A-H
G2RK-1A
G2R-1-H
G2RK-1
G2R-2A-H
G2RK-2A
G2R-2-H
G2RK-2
Double-winding
latching
50
pcs/tray
DC
AC
DC
100
pcs/tray
Quick-connect Standard
Unsealed
G2R-1A-T
G2R-1-T
−
−
Note 1. Full-wave rectifier and supersonic cleaner compatible models are also available. Refer to page 3.
2.Sockets for PCB terminal models are not provided.
1
G2R
■Ordering Information
PCB Power Relay
● PCB Terminal Models
Number of poles
Contact form
1-pole
Rated coil voltage
2-pole
Classification
Enclosure rating
Model
Model
Rated coil voltage
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
NO
G2R-1A
G2R-2A
Flux protection
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
NO/NC
NO
G2R-1
G2R-2
Standard
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
G2R-1A4
G2R-14
G2R-2A4
G2R-24
Fully sealed
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
NO/NC
NO
G2R-1A-H
G2R-1-H
G2RK-1A
G2RK-1
5, 6, 12, 24, 48 VDC
5, 6, 12, 24, 48 VDC
5, 6, 12, 24 VDC
5, 6, 12, 24 VDC
12, 24, 48 VDC
100 VDC
G2R-2A-H
G2R-2-H
G2RK-2A
G2RK-2
5, 6, 12, 24, 48 VDC
5, 6, 12, 24, 48 VDC
5, 12, 24 VDC
G
2
R
High-sensitivity
NO/NC
NO
Flux protection
Flux protection
Fully sealed
Double-winding
latching
NO/NC
5, 6, 12, 24 VDC
NO
G2R-1AZ
G2R-1Z
−
−
−
−
5, 6, 12, 24, 48 VDC
100 VDC
NO/NC
NO
Bifurcated
contact
5, 12, 24, 48 VDC
100 VDC
G2R-1AZ4
G2R-1Z4
5, 12, 24, 48 VDC
100 VDC
NO/NC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
NO
G2R-1A-E
G2R-1-E
High-capacity
Flux protection
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
NO/NC
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A AC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VAC.
2
G2R
● Quick-connect Terminal (#187)
PCB Power Relay
Number of poles
Contact form
1-pole
Rated coil voltage
Classification
Enclosure rating
Model
12, 24, 100/(110) VAC
200/(220) VAC
NO
G2R-1A-T
5, 6, 12, 24, 48 VDC
100 VDC
Standard
Unsealed
12, 24, 100/(110) VAC
200/(220) VAC
NO/NC
G2R-1-T
5, 6, 12, 24, 48 VDC
100 VDC
● Full-wave Rectifier
Number of poles
Contact form
1-pole
2-pole
Classification
Enclosure rating
Model
Rated coil voltage
5, 12, 24 VDC
100 VDC
Model
Rated coil voltage
5, 6, 12, 24, 48 VDC
100 VDC
NO
G2R-1A-Z
G2R-2A-Z
Flux protection
5, 12, 24, 48 VDC
100 VDC
12, 24, 48 VDC
100 VDC
NO/NC
NO
G2R-1-Z
G2R-2-Z
Standard
5, 12, 48 VDC
100 VDC
24, 48 VDC
G2R-1A4-Z
G2R-14-Z
G2R-2A4-Z
G2R-24-Z
100 VDC
Fully sealed
5, 12, 24, 48 VDC
100 VDC
5, 12, 24 VDC
100 VDC
G
2
NO/NC
R
5, 12, 24 VDC
100 VDC
NO
G2R-1A-EZ
G2R-1-EZ
High-capacity
Flux protection
−
NO/NC
12, 24, 48 VDC
● For Ultrasonically Cleanable
Number of poles
Contact form
1-pole
2-pole
Classification
Enclosure rating
Model
Rated coil voltage
12, 24, 100/(110) VAC
200/(220) VAC
Model
Rated coil voltage
100/(110) VAC
−
NO
G2R-1A4-U
G2R-2A4-U
5, 6, 12, 24, 48 VDC
5, 12, 24 VDC
Standard
Fully sealed
100/(110) VAC
200/(220) VAC
24, 100/(110) VAC
200/(220) VAC
NO/NC
G2R-14-U
G2R-24-U
5, 12, 24, 48 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A-T AC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VAC.
3
G2R
■Ratings
PCB Power Relay
● Coil
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage
(V)
Power
consumption
(VA, W)
Item Rated current (mA)
Coil resistance
(Ω)
Classification
Rated voltage
12 VAC
50 Hz
93
60 Hz
75
% of rated voltage
65
260
• Standard
24 VAC
46.5
11
37.5
• Quick-connect
• Fully sealed
• High-capacity
140%
(at 23°C)
Approx. 0.9
(60 Hz)
80% max.
70% max.
30% min.
100/(110) VAC
200/(220) VAC
5 VDC
9/(10.6)
4.5/(5.3)
4,600
20,200
47
5.5
106
88.2
6 VDC
68
• Standard
• High-capacity
• Bifurcated contact
• Quick-connect
• Fully sealed
12 VDC
43.6
21.8
11.5
5.3
275
170%
(at 23°C)
15% min.
Approx. 0.53
24 VDC
1,100
4,170
18,870
70
48 VDC
100 VDC
5 VDC
71.4
60
6 VDC
100
170%
(at 23°C)
• High-sensitivity
12 VDC
30
400
70% max.
15% min.
Approx. 0.36
24 VDC
15
1,600
6,400
48 VDC
7.5
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of+15%/-20% (AC rated current) or ±10% (DC coil resistance).
2.AC coil resistances shown above are only reference values.
G
2
R
3.The operating characteristics are measured at a coil temperature of 23°C.
4.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
● Coil: Double-winding Latching Relays
Must set
voltage (V) voltage (V)
Must reset Max. voltage
Item
Set Coil
Reset coil
Power consumption
(V)
Rated current
Coil resistance
Rated current
Coil resistance
Set Coil
(mW)
Reset coil
(mW)
% of rated voltage
Rated voltage
5 VDC
(mA)
(Ω)
(mA)
119
100
50
(Ω)
42
60
167
30
43.5
170
694
6 VDC
138
140%
(at 23°C)
Approx.
850
Approx.
600
70% max.
70% max.
12 VDC
24 VDC
70.6
34.6
240
960
25
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.The operating characteristics are measured at a coil temperature of 23°C.
3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
4
G2R
● Contacts: Fully Protection Type
PCB Power Relay
Standard type
Classification
High-capacity type
Bifurcated contact type
High-sensitivity type
Quick-connect Terminal (1single-pole type)
Number of poles
1-pole
Inductive
load
2-pole
Inductive
load
1-pole
2-pole
1-pole
2-pole
Inductive
load
Inductive
Inductive
Inductive
load
Resistive
load
Resistive
load
Resistive
load
load
Resistive
load
load
Resistive
load
Resistive
load
Load
(cos
L/R = 7 ms)
φ
= 0.4;
(cos
L/R = 7 ms)
φ
= 0.4;
(cos
φ
= 0.4;
(cos
φ
= 0.4;
(cos
L/R = 7 ms)
Single
φ
= 0.4;
(cos
φ
= 0.4;
Item
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
Contact type
Single
Single
Bifurcated
Ag-alloy (Cd free)
8 A at 250 5 A at 250 2 A at 250 5 A at 250 2 A at 250 3 A at 250 1 A at 250
Contact material
10 A at
7.5 A at
5 A at 250 2 A at 250 16 A at
250 VAC
10 A at 30 5 A at 30
VDC VDC
250 VAC
VAC
5 A at 30
VDC
VAC
3 A at 30
VDC
250 VAC
16 A at 30 8 A at 30
VDC VDC
VAC
VAC
5 A at 30
VDC
VAC
3 A at 30
VDC
VAC
5 A at 30
VDC
VAC
3 A at 30
VDC
VAC
3 A at 30
VDC
VAC
1.5 A at
30 VDC
Rated load
Rated carry current
10 A
5 A
16 A
5 A
5 A
3 A
Max. switching voltage
Max. switching current
380 VAC, 125 VDC
380 VAC, 125 VDC
380 VAC, 125 VDC
10 A
5 A
16 A
5 A
5 A
3 A
Failure rate (P level)
(reference value) *
100 mA at 5 VDC
10 mA at 5 VDC
100 mA at 5 VDC
1 mA at 5 VDC
100 mA at 5 VDC
10 mA at 5 VDC
* This value was measured at a switching frequency of 120 operations/min.
● Contacts: Flux Sealed Type
Classification
Standard type (Single contact type)
Bifurcated contact type
1-pole
Number of poles
1-pole
(cos
2-pole
Resistive load
(cos = 1)
Inductive load
= 0.4; L/R = 7 ms)
Resistive load
(cos = 1)
Inductive load
Resistive load
(cos = 1)
Inductive load
Load
Item
φ
φ
φ
(cos
Single
Ag-alloy (Cd free)
φ
= 0.4; L/R = 7 ms)
φ
(cos
φ
= 0.4; L/R = 7 ms)
Contact type
Single
Bifurcated
G
2
R
Contact material
8 A at 250 VAC
8 A at 30 VDC
6 A at 250 VAC
4 A at 30 VDC
4 A at 250 VAC
4 A at 30 VDC
1.5 A at 250 VAC
2.5 A at 30 VDC
5 A at 250 VAC
5 A at 30 VDC
2 A at 250 VAC
3 A at 30 VDC
Rated load
Rated carry current
8 A
4 A
5 A
Max. switching voltage
Max. switching current
380 VAC, 125 VDC
8 A
380 VAC, 125 VDC
4 A
380 VAC, 125 VDC
5 A
Failure rate (P level)
(reference value) *
100 mA at 5 VDC
10 mA at 5 VDC
1 mA at 5 VDC
* This value was measured at a switching frequency of 120 operations/min.
● Contacts: Latching Type
Number of poles
1-pole
(cos
2-pole
(cos
Resistive load
(cos = 1)
Inductive load
= 0.4; L/R = 7 ms)
Resistive load
(cos = 1)
Inductive load
φ = 0.4; L/R = 7 ms)
Load
Item
φ
φ
φ
Contact type
Single
Single
Contact material
Ag-alloy (Cd free)
5 A at 250 VAC
5 A at 30 VDC
3.5 A at 250 VAC
2.5 A at 30 VDC
3 A at 250 VAC
3 A at 30 VDC
1.5 A at 250 VAC
2 A at 30 VDC
Rated load
Rated carry current
5 A
3 A
Max. switching voltage
Max. switching current
380 VAC, 125 VDC
5 A
380 VAC, 125 VDC
3 A
Failure rate (P level)
(reference value) *
100 mA at 5 VDC
10 mA at 5 VDC
* This value was measured at a switching frequency of 120 operations/min.
5
G2R
■Characteristics
PCB Power Relay
● Standard Relays
Double-winding Latching Relays
Item
Number of poles
1-pole
30 mΩ max.
2-pole
50 mΩ max.
Item
Number of poles
1-pole
30 mΩ max.
2-pole
50 mΩ max.
Contact resistance *1
Contact resistance *1
Operate time *2
Release time *2
Max.
operating
frequency
Time *2
Min. set pulse width *3
Time *2
Min. reset pulse
width *3
20 ms max.
30 ms
20 ms max.
15 ms max.
Set
AC: 10 ms max.; DC: 5 ms max.
18,000 operations/hr
Mechanical
Reset
30 ms
Electrical
1,800 operations/hr
1,000 MΩ min.
Max.operating Mechanical
frequency Electrical
Insulation resistance *4
Between coil and
18,000 operations/hr
1,800 operations/hr
1,000 MΩ min.
Insulation resistance *3
Between coil and
5,000 VAC, 50/60 Hz for 1 min
contacts
Between contacts
of different polarity
Between contacts
of the same
5,000 VAC, 50/60 Hz for 1 min
3,000 VAC, 50/60 Hz
for 1 min
Dielectric
strength
contacts
-
Between contacts of
different polarity
Between contacts of
the same polarity
Between set and
reset coils
3,000 VAC,
50/60 Hz for 1 min
−
Dielectric
strength
1,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
Clearance: 8 mm, Creepage: 8 mm
polarity
Insulation Between coil and
distance
Clearance: 8 mm, Creepage: 8 mm
contacts
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
1,000 m/s2
Insulation
distance
Between coil and
contacts
Destruction
Vibration
resistance
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
1,000 m/s2
Malfunction
Destruction
Malfunction
Destruction
Vibration
resistance
Shock
resistance
Malfunction
Destruction
Malfunction
200 m/s2 when energized;
100m/s2 when no energized
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min.
(at 18,000 operations/hr)
Shock
resistance
Set: 500m/s2 Armature OFF
Reset: 200m/s2 Contact OFF
10,000,000 operations min
(at 18,000 operations/hr)
100,000 operations min. (at 1,800
operations/hr under rated load)
-40°C to 70°C (with no icing or
condensation)
Mechanical
Electrical
Durability
Mechanical
Electrical
100,000 operations min.
Durability
(at 1,800 operations/hr under rated load)
-40°C to 70°C (with no icing)
5% to 85%
G
2
R
Ambient operating temperature
Ambient operating humidity
Weight
Ambient operating temperature
Approx. 17 g (Approx. 20 g *4)
Ambient operating humidity
Weight
5% to 85%
Approx. 17 g
Note: The values here are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2. Measurement conditions: Rated operating voltage applied, not including
contact bounce.
Note: The values here are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2. Measurement conditions: Rated operating voltage applied, not including
contact bounce.
*3. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength
was measured.
*3. Measurement couditions: Rated operating voltage applied.
*4. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength
was measured.
*4. Value for quick-connect terminals.
■Engineering Data
● Maximum Switching Capacity
Flux Protection/Plug-in Relays
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T
G2R-1-E, G2R-1A-E
G2R-1Z, G2R-1AZ
50
50
50
AC resistive load
16
10
AC resistive load
10
10
AC resistive load
AC
5
5
5
AC
DC resistive load
inductive load
(cosφ = 0.4)
inductive load
(cosφ = 0.4)
DC resistive load
AC
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
DC resistive load
DC inductive load
(L/R = 7 ms)
1
1
1
DC inductive load
(L/R = 7 ms)
0.5
0.5
0.1
0.5
0.1
0.1
0
5
10 20 30 50 100
500
0
5
10 20 30 50 100
500
0
5
10 20 30 50 100
500
Switching voltage (V)
Switching voltage (V)
Switching voltage (V)
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A
G2R-2-H, G2R-2A-H
50
50
10
10
5
AC resistive load
AC resistive load
5
AC
inductive load
(cosφ = 0.4)
DC resistive load
AC
DC resistive load
1
1
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
0.5
0.5
DC inductive load
(L/R = 7 ms)
0.1
0.1
0
5
10 20 30 50 100
500
0
5
10 20 30 50 100
500
Switching voltage (V)
Switching voltage (V)
6
G2R
G2RK-1A, G2RK-1
PCB Power Relay
G2RK-2A, G2RK-2
50
50
10
5
10
AC resistive load
5
3
AC resistive load
AC
inductive load
(cosφ = 0.4)
DC resistive load
1
AC
DC resistive load
1
inductive load
(cosφ = 0.4)
0.5
0.5
DC inductive load
DC inductive load
(L/R = 7 ms)
(L/R = 7 ms)
0.1
0.1
0
5
10 20 30 50 100
500
0
5
10 20 30 50 100
500
Switching voltage (V)
Switching voltage (V)
Fully Sealed Relays
G2R-14, G2R-1A4
50
G2R-24, G2R-2A4
G2R-1Z4, G2R-1AZ4
50
50
AC resistive load
10
5
10
5
10
5
AC resistive load
AC resistive load
AC
inductive load
(cosφ = 0.4)
DC resistive load
G
2
R
DC resistive load
1
AC
DC resistive load
AC
inductive load
1
1
inductive load
(cosφ = 0.4)
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
0.5
0.5
0.5
DC inductive load
(L/R = 7 ms)
0.1
0.1
0.1
0
5
10 20 30 50 100
300 500
0
5
10 20 30 50 100
300 500
0
5
10 20 30 50 100
300 500
Switching voltage (V)
Switching voltage (V)
Switching voltage (V)
● Durability
Flux Protection/Plug-in Relays
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T
G2R-1-E, G2R-1A-E
G2R-1Z, G2R-1AZ
1,000
1,000
1,000
500
500
500
250 VAC/30 VDC
resistive load
300
300
300
250 VAC/30 VDC
resistive load
100
100
100
250 VAC inductive load
(cosφ = 0.4)
30 VDC inductive load (L/R = 7ms)
50
50
30
50
30
250 VAC/30 VDC
resistive load
30
10
10
10
250 VAC inductive load (cosφ = 0.4)
30 VDC inductive load (L/R = 7ms)
250 VAC inductive load
(cosφ = 0.4)
30 VDC inductive load (L/R = 7ms)
5
3
5
3
5
3
0
0
0
2
4
5
6
7.5 8
10
12
14
2
4
6
8
10
12
14
16 18
1
2
3
4
5
6
Switching current (A)
Switching current (A)
Switching current (A)
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A
G2R-2-H, G2R-2A-H
1,000
1,000
500
500
300
300
250 VAC/30 VDC
resistive load
100
100
30 VDC inductive load
(L/R = 7ms)
30 VDC inductive load (L/R = 7ms)
50
50
30
250 VAC/30 VDC
resistive load
30
10
10
250 VAC inductive load
(cosφ = 0.4)
250 VAC inductive load
(cosφ = 0.4)
5
3
5
3
0
0
1
2
3
4
5
6
1
1.5
2
3
4
Switching current (A)
Switching current (A)
7
G2R
G2RK-1A, G2RK-1
PCB Power Relay
G2RK-2A, G2RK-2
1,000
1,000
500
500
300
300
250 VAC/30 VDC
resistive load
100
100
30 VDC inductive load
(L/R = 7ms)
250 VAC/30 VDC
resistive load
50
30
50
30
250 VAC inductive load
(cosφ = 0.4)
250 VAC inductive load
(cosφ = 0.4)
10
5
10
5
3
30 VDC inductive load (L/R = 7ms)
3
0
0
1
2
2.5
3
3.5
4
5
6
1
1.5
2
2.5
3
4
Switching current (A)
Switching current (A)
Fully Sealed Relays
G2R-14, G2R-1A4
G2R-24, G2R-2A4
G2R-1Z4, G2R-1AZ4
1,000
1,000
1,000
500
500
500
300
300
300
30 VDC inductive load (L/R = 7ms)
250 VAC/30 VDC
resistive load
30 VDC inductive load (L/R = 7ms)
100
100
100
250 VAC inductive load
(cosφ = 0.4)
250 VAC/30 VDC
resistive load
50
30
50
30
50
30
250 VAC/30 VDC
resistive load
G
2
R
10
10
10
250 VAC inductive load
(cosφ = 0.4)
250 VAC inductive load
(cosφ = 0.4)
30 VDC inductive load (L/R = 7ms)
5
3
5
3
5
3
0
0
0
2
4
6
8
10
12
1
1.5
2
2.5
3
4
5
6
1
2
3
4
5
6
Switching current (A)
Switching current (A)
Switching current (A)
● Ambient Temperature vs. Maximum
Coil Voltage
● Ambient Temperature vs. Must
Operate and Must Release Voltage
G2R-1
G2R-2
250
200
100
100
Must operate voltage
Must release voltage
Must operate voltage
Must release voltage
Sample: G2R-1
Number of Relays: 5 pcs
Sample: G2R-2
Number of Relays: 5 pcs
80
60
40
80
60
40
max.
X
max.
X
DC coil
170
150
140
min.
min.
110
100
max.
X
max.
X
AC coil
min.
50
20
0
20
0
min.
0
−25 20
30
40
50
60 70
80
90 100
−60
−40
−20
0
20
40
60
80
−60
−40
−20
0
20
40
60
80
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum
value in a varying range of operating power voltage,
not a continuous voltage.
● Shock Malfunction
● Keep-power decrement with time
G2R-1 Number of Relays: 5 pcs
G2R-2 Number of Relays: 5 pcs
G2RK-1
Y
Y
Test Conditions:
Shock is applied in
±X, ±Y, and ±Z
directions three times
each with and without
energizingtheRelays
to check the number
of contact
Test Conditions:
Shock is applied in
±X, ±Y, and ±Z
directionsthreetimes
eachwithandwithout
energizing the
Relays to check the
number of contact
malfunctions.
Requirement:
200 m/s2 when
energized; 100m/s2
when de-energized
Shock direction
160
SPST-NO (1a)
SPST-NC (1c)
1,000
1,000
Number of Relays: 50 pcs
SPST-NO (1a)
SPST-NC (1c)
Measurement: after the relay kept static by
applying a rated voltage, leave the relay at room
temperature of 20°C to 30°C, and high temperature
of 80°C 2°C respectively, to measure how the
140
800
600
400
200
800
600
400
200
X
X
Z'
Z'
120 keep-power varies with time.
MAX
Room
temperature
)
MIN
100
80
malfunctions.
270
200
Requirement:
200 m/s2 when
MAX
High
temperature
200
400
600
800
)
MIN
energized; 100m/s2
when de-energized
400
600
800
60
Z
X'
Z
X'
Shock direction
40
X
X'
X
X'
Y
Y
20
Z
1,000
1,000
Z
Unit: m/s2
Unit: m/s2
Y'
Y'
Z'
Z'
0
50 100
500 1,000
5,000 10,000
Y'
Y'
Elapsed time (H)
8
G2R
■Dimensions
PCB Power Relay
Relays with PCB Terminals
(SPDT (1c) Relays)
G2R-1(-Z)
G2R-1Z
G2R-1-H
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.7)*
29 max.
(28.8)*
3.5 3.5
(2.7)
1
2
3
25.5 max.
(25.3)*
7.5
Five, 1.3-dia.
holes
(0.3)
5
4
(2.1)
20
(No coil polarity)
0.5
0.5**
** Average value
1
4
0.3
This illustration is the
G2R-1 model.
0.16
** With AC coil or “-H” models: 0.3.
Relays with PCB Terminals
(SPST-NO (1a) Relays)
G2R-1A(-Z)
G2R-1AZ
G2R-1A-H
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.7)*
29 max.
(28.8)*
3.5
(2.7)
1
3
25.5 max.
(25.3)*
7.5
Four, 1.3-dia.
holes
(0.3)
G
2
R
5
4
(2.1)
20
(No coil polarity)
0.3
0.5**
1
4
0.16
** Average value
** With AC coil or “-H” models: 0.3.
This illustration is the
G2R-1A model.
Relays with PCB Terminals
(SPDT (1c) /High-capacity Relays)
G2R-1-E(Z)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.6)*
29 max.
(28.6)*
Eight, 1.3-dia. holes
2.5
2.5
(2.7)
7.5
1
2
7
3
6
4
5
25.5 max.
(24.9)*
(0.3)
8
(No coil polarity)
0.5
0.3
1
4
(2.1)
5
5
(2.1)
0.3
* Average value
20
0.16
Relays with PCB Terminals
(SPST-NO (1a)/High-capacity Relays)
G2R-1A-E(Z)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.6)*
29 max.
(28.6)*
2.5
Six, 1.3-dia. holes
2.5
(2.7)
7.5
1
3
4
5
25.5 max.
(24.9)*
(0.3)
8
6
(No coil polarity)
0.3
* Average value
1
4
(2.1)
20
5
(2.1)
0.3
0.16
Note: Orientation marks are indicated as follows:
9
G2R
PCB Power Relay
Relays with PCB Terminals
(SPDT (1c) Relays)
G2R-14(-Z)(-U)
13.5 max.
(12.9)*
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
3.5 3.5
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
29 max.
(28.6)*
G2R-1Z4
25.5 max.
(24.8)*
(2.7)
1
2
3
7.5
Five, 1.3-dia.
holes
5
4
0.5
0.5
1
(2.1)
20
4
(No coil polarity)
0.3
* Average value
0.16
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Relays with PCB Terminals
13.5 max.
(12.9)*
29 max.
(28.6)*
(SPST-NO (1a) Relays)
G2R-1A4(-Z)(-U)
G2R-1AZ4
3.5
25.5 max.
(24.8)*
(2.7)
1
3
7.5
Four, 1.3-dia.
holes
5
4
0.5
1
4
(2.1)
20
(No coil polarity)
0.3
* Average value
0.16
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
3.5 3.5
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Double-winding Latching Relays with
13 max.
(12.8)*
29 max.
(28.8)*
PCB Terminals
(SPDT (1c) Relays)
G2RK-1
G
2
R
1
2
3
4
(2.7)
25.5 max.
(25.2)*
-
-
S
R
+
+
7.5
(0.3)
Seven, 1.3-dia.
holes
7
6
5
(After confirming coil
polarity, wire correctly.)
0.5
5
0.3
0.5
0.16
1
4
(2.1)
20
1
* Average value
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
3.5
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.8)*
Double-winding Latching Relays with
29 max.
(28.8)*
PCB Terminals
(SPST-NO (1a) Relays)
G2RK-1A
1
2
4
−
+
−
25.5 max.
(25.2)*
(2.7)
S
R
+
7.5
7
6
5
(0.3)
Six, 1.3-dia.
holes
(After confirming coil
polarity, wire correctly.)
1
0.3
0.5
0.16
5
4
(2.1)
20
1
* Average value
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
2.5
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Double-winding Latching Relays with PCB Terminals
(DPDT (2c) Relays)
13 max.
G2RK-2
(12.8)*
29 max.
(28.8)*
Ten, 1.3-dia. holes
2.5
1
2
3
8
4
7
5
6
-
-
(2.7)
7.5
S
+
10
R
25.5 max.
(25.3)*
+
9
(0.3)
(2.7)
(After confirming coil
polarity, wire correctly.)
0.5
0.15
1
4
0.3
0.5
1
(2.1)
5
5
5
(2.1)
* Average value
20
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
2.5
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Double-winding Latching Relays with PCB Terminals
(DPST-NO (2a) Relays)
13 max.
(12.8)*
G2RK-2A
29 max.
(28.8)*
Eight, 1.3-dia. holes
2.5
1
2
4
5
-
-
(2.7)
7.5
S
R
25.5 max.
(25.3)*
+
+
10
9
7
6
(0.3)
(2.7)
(After confirming coil
polarity, wire correctly.)
0.3
1
0.5
0.15
1
4
5
5
(2.1)
(2.1)
* Average value
20
Note: Orientation marks are indicated as follows:
10
G2R
PCB Power Relay
Relays with PCB Terminals
(DPDT (2c) Relays)
G2R-2(-Z)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.7)*
29 max.
(28.8)*
G2R-2-H
Eight, 1.3-dia. holes
2.5
2.5
(2.7)
7.5
1
2
7
3
6
4
5
25.5 max.
(25.2)*
(0.3)
8
(No coil polarity)
0.5
0.5
1
4
0.3
(2.1)
5
5
(2.1)
0.15
* Average value
20
Relays with PCB Terminals
(DPST-NO (2a) Relays)
G2R-2A
G2R-2A-H
G2R-2A-Z
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13 max.
(12.7)*
29 max.
(28.8)*
Six, 1.3-dia. holes
2.5
2.5
(2.7)
7.5
1
3
4
5
25.5 max.
(25.2)*
(0.3)
8
6
(No coil polarity)
0.5
1
4
G
2
R
0.3
(2.1)
20
5
(2.1)
0.15
* Average value
Relays with PCB Terminals
(DPDT (2c) Relays)
G2R-24(-Z)(-U)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13.5 max.
(12.8)*
29 max.
(28.6)*
Eight, 1.3-dia. holes
2.5
2.5
(2.7)
7.5
1
2
7
3
6
4
5
25.5 max.
(24.7)*
8
(No coil polarity)
0.5
0.5
1
4
(2.1)
5
5
(2.1)
* Average value
0.15
20
Relays with PCB Terminals
(DPST-NO (2a) Relays)
G2R-2A4(-Z)(-U)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
13.5 max.
(12.8)*
29 max.
(28.6)*
Six, 1.3-dia. holes
2.5
2.5
(2.7)
7.5
1
3
4
5
25.5 max.
8
6
(No coil polarity)
0.5
* Average value
1
4
0.3
(2.1)
20
5
(2.1)
0.15
Note: Orientation marks are indicated as follows:
11
G2R
Relays with Quick-connect
Terminals
PCB Power Relay
30.5 max.
(29.7)*
(SPDT (1c) Relays)
G2R-1-T
7.5
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
5.2
5.2
17.5
* Average value
Five, 1.3-dia. holes
Two M3 or
two 3.5 dia.
4.75
0.5
38
1
8.5
2
4
3
5
29.5 max.
(No coil polarity)
Note: Model number of
quick-connect terminal is 187.
45 max.
(43.9)*
14 max.
(13.1)*
2.5
Relays with Quick-connect
Terminals
30.5 max.
(29.7)*
(SPST-NO (1a) Relays)
G2R-1A-T
7.5
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
5.2
17.4
* Average value
G
2
R
Two M3 or
two 3.5 dia.
Four, 1.3-dia. holes
38
4.75
0.5
1
4
3
8.5
5
(No coil polarity)
29.5 max.
Note: Model number of
quick-connect terminal is 187.
45 max.
(43.9)*
14 max.
(13.1)*
2.5
Note: Orientation marks are indicated as follows:
12
G2R
■Approved Standards
PCB Power Relay
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL Recognized:
1-pole
File No. E41643
CSA Certified:
1-pole
File No. LR31928
Number of
test
operations
Number of
test
operations
Contact
form
Contact
form
Model
Coil ratings
Contact ratings
Model
Coil ratings
Contact ratings
G2R-1A
G2R-1A
10 A, 250 VAC (General
Use) at 40°C
100,000
6,000
10 A, 250 VAC (General
Use) at 40°C
G2R-1A4
G2R-1A-H
G2R-1A-T
G2R-1
100,000
SPST-NO
(1a)
G2R-1A4
SPST-NO
(1a)
5 A, 277 VAC (General
Use) at 40°C
G2R-1A-H
G2R-1A-T
5 to 110 VDC
12 to 220 VAC
10 A, 30 VDC
(Resistive) at 40°C
5 to 110 VDC
12 to 220 VAC
100,000
25,000
G2R-14
5 A, 30 VDC (Resistive)
at 40°C
SPDT
(1c)
100,000
25,000
G2R-1
G2R-1-H
G2R-1-T
G2R-1AZ
G2R-1AZ4
G2R-1Z
TV-3 (N. O. only) at
40°C
G2R-14
SPDT
(1c)
G2R-1-H
G2R-1-T
G2R-1AZ
G2R-1AZ4
G2R-1Z
G2R-1Z4
TV-3 (N. O. only) at
40°C
SPST-NO
(1a)
5 A, 250 VAC (General
Use) at 40°C
5 to 110 VDC
12 to 220 VAC
6,000
SPST-NO
(1a)
10 A, 250 VAC (General
Use) at 40°C
SPDT
(1c)
5 A, 30 VDC (Resistive)
at 40°C
5 to 110 VDC
12 to 220 VAC
6,000
G2R-1Z4
SPDT
(1c)
5 A, 30 VDC (Resistive)
at 40°C
16 A, 250 VAC (General
Use) at 40°C
5 to 110 VDC 16 A, 30 VDC
12 to 220 VAC (Resistive) at 40°C
TV-3 (N. O. only) at
SPST-NO
(1a)
G2R-1A-E
G2R-1-E
6,000
SPST-NO
(1a)
16 A, 250 VAC (General
Use) at 40°C
5 to 110 VDC 16 A, 30 VDC
12 to 220 VAC (Resistive) at 40°C
TV-3 (N. O. only) at
G2R-1A-E
30,000
6,000
G
2
R
SPDT
(1c)
25,000
40°C
SPDT
(1c)
G2R-1-E
25,000
2-pole
40°C
Number of
test
operations
Contact
form
2-pole
Model
Coil ratings
Contact ratings
Number of
test
operations
Contact
form
Model
Coil ratings
Contact ratings
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2
5 A, 250 VAC (General
Use) at 40°C
6,000
100,000
25,000
DPST-NO
(2a)
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2
5 A, 250 VAC (General
Use) at 40°C
6,000
100,000
25,000
DPST-NO
(2a)
5 to 110 VDC 5 A, 30 VDC (Resistive)
12 to 220 VAC at 40°C
5 to 110 VDC 5 A, 30 VDC (Resistive)
12 to 220 VAC at 40°C
DPDT
(2c)
G2R-24
TV-3 (N. O. only) at
40°C
G2R-24-H
DPDT
(2c)
G2R-24
TV-3 (N. O. only) at
40°C
G2R-24-H
EN/IEC, VDE Certified: Certificate No. 40015012
Number of
test
operations
Contact
form
Model
Coil ratings
Contact ratings
5, 6, 12, 24,
48, 100 VDC
12, 24,
16 A, 250 VAC
(cos = 1.0) at 70°C
G2R-1(A)-E
1
φ
100/110,
200/220 VAC
5, 6, 12, 24, 10 A, 250 VAC
48, 100 VDC (cos
12, 24,
100/110,
φ = 1.0) at 40°C
1
2
100,000
10 A, 30 VDC (0 ms) at
40°C
200/220 VAC
G2R-(
)
5, 6, 12, 24, 5 A, 250 VAC
48, 100 VDC (cos
12, 24,
φ = 1.0) at 40°C
5 A, 30 VDC (0 ms) at
40°C
100/110,
200/220 VAC
EN, TÜV Certified: Registration No. R50030327
Number of
test
operations
Contact
form
Model
Coil ratings
Contact ratings
5 to 110 VDC 16 A, 250 VAC
12 to 220 VAC (cos = 1.0) at 70°C
10 A, 250 VAC
(cos = 1.0) at 70°C
G2R-1(A)-E
1
φ
φ
5 to 110 VDC
12 to 220 VAC
1
2
10 A, 30 VDC (0 ms) at
70°C
100,000
G2R-(
)
5 A, 250 VAC
(cosφ = 1.0) at 40°C
5 to 110 VDC
12 to 220 VAC
5 A, 30 VDC (0 ms) at
40°C
13
G2R
■Precautions
PCB Power Relay
●Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Mounting
Refer to the following table for
examples of positive-lock connectors
made by AMP. Contact the
manufacturer directly for details on
connectors including availability.
Receptacle
Therefore, do not use the Relay in a
strong magnetic field environment.
• When mounting a number of relays on
a PCB, be sure to provide a minimum
mounting space of 5 mm between the
two juxtaposed relays as shown
below.
●Degradation over Time of Double-
winding Latching Relays Holding
Ability
• If a double-winding latching Relay is
used left set for an extended period,
changes over time will degrade the
magnetic force, and the reduction in
holding ability may cause the set
status to be released. This is also
because of the properties of semi-hard
magnetic material, and the rate of
degradation over time depends on the
ambient environment (e.g.,
Type
Positive housing
terminals
AMP172074-1
AMP170330-1 (natural color)
(170324-1) AMP172074-4
AMP170331-1 (yellow)
(170325-1) AMP172074-5
AMP170332-1 (green)
(170326-1) AMP172074-6
(blue)
5 mm
min.
#187
(Width
4.75)
5 mm min.
Note: The numbers shown in parentheses are for
air-feeding.
●Handling
• The terminals are compatible with
Faston receptacle #187 and are
suitable for positive-lock mounting.
Use only Faston terminals with the
specified numbers.
●Minimum Pulse Width of Double-
winding Latching Relays
temperature, humidity, vibration, and
presence or absence of external
magnetic fields).Perform maintenance
at least once a year by resetting,
applying the rated voltage again, and
then setting.
• The minimum pulse width shown in
the table of characteristics are values
measured under conditions of ambient
temperature at 23°C with rated
operating voltage imposed on coil.
The Relay may not provide a
G
2
R
Select leads for connecting Faston
receptacles with wire diameters that
are within the allowable range for the
load current.
●Wiring High Capacity (-E) Models
• High-capacity models (-E) have a
structure that connects two terminals
from one contact.
satisfactory performance as its holding
ability decreases depending on the
operating circuit conditions and
ambient temperature, or decreases
due to degradation over time.
Do not apply excessive force to the
terminals when mounting or
dismounting the Faston receptacle.
Also, do not insert terminals at an
angle, or insert/remove multiple
terminals at the same time. Be sure to
insert and remove terminals carefully
one at a time.
When designing the circuit, use both
terminals.
If you use only one terminal, the relay
may be unable to satisfy specified
performance.
In actual operation, impose to the coil
a rated operating voltage with a pulse
width that is suitable to the actual load,
and reset the setting at least once a
year, to correspond to the degradation
over time.
• When using the Relay in a strong
magnetic field environment, the
magnetic body may be demagnetized
due to the influence of environment,
causing the Relay to malfunction.
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K013-E1-17
0316(0207)(O)
14
G2R-1-TDC100 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
G2R-1-TDC110 | OMRON | Power PCB Relay | 获取价格 | |
G2R-1-Z | OMRON | PCB Power Relays | 获取价格 | |
G2R-13-S | OMRON | PCB Relay A Power Relay for a Variety of Purposes with Various Models | 获取价格 | |
G2R-13-S-100VDC | OMRON | Power/Signal Relay, SPDT, Momentary, 0.005A (Coil), 100VDC (Coil), 530mW (Coil), 8A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, | 获取价格 | |
G2R-13-S-110VAC | OMRON | Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 8A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount | 获取价格 | |
G2R-13-S-12VAC | OMRON | Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 8A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount | 获取价格 | |
G2R-13-S-12VDC | OMRON | Power/Signal Relay, SPDT, Momentary, 0.044A (Coil), 12VDC (Coil), 530mW (Coil), 8A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, | 获取价格 | |
G2R-13-S-220VAC | OMRON | Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 8A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount | 获取价格 | |
G2R-13-S-230VAC | OMRON | Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 8A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount | 获取价格 | |
G2R-13-S-240VAC | OMRON | Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 8A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount | 获取价格 |
G2R-1-TDC100 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6