G2R-1A-E-220VAC [OMRON]

Power/Signal Relay, SPST, Momentary, 900mW (Coil), 10A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT;
G2R-1A-E-220VAC
型号: G2R-1A-E-220VAC
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, SPST, Momentary, 900mW (Coil), 10A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT

文件: 总16页 (文件大小:1570K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TPeCxBt Power Relay – G2R  
A Power Relay for a Variety of  
Purposes with Various Models  
ROHS compliant  
Conforms to EN 61810-1, UL508, CSA22.2,  
SEV, SEMKO.  
Meets EN60335-1 requirements for household  
products.  
Clearance and creepage distance:  
8 mm/8 m.  
Models with CTI250 material available.  
High-sensitivity (360 mW) and high-capacity  
(16 A) types available.  
Double-winding latching type available.  
Ordering Information  
Contact Form  
SPDT DPST-NO  
Classification  
Enclosure  
Ratings  
Coil  
Ratings  
SPST-NO  
G2R-1A  
DPDT  
G2R-2  
PCB terminal  
General-purpose  
Flux protection  
Fully sealed  
AC/DC  
DC  
G2R-1  
G2R-2A  
G2R-1A4  
G2R-1AZ  
G2R-14  
G2R-1Z  
G2R-2A4  
G2R-24  
Bifurcated contact  
Flux protection  
Fully sealed  
G2R-1AZ4 G2R-1Z4  
G2R-1A-E G2R-1-E  
G2R-1A-H G2R-1-H  
High-capacity  
High-sensitivity  
Flux protection  
Flux protection  
AC/DC  
DC  
G2R-2A-H G2R-2-H  
Double-winding latching Flux protection  
General-purpose Unsealed  
G2RK-1A  
G2RK-1  
G2RK-2A  
G2RK-2  
Quick connect  
(upper bracket  
mounting)  
AC  
DC  
G2R-1A-T G2R1-T  
Note: 1. When ordering, add the rated coil voltage to the model number.  
Example: G2R-1A 12 VDC  
Rated coil voltage  
2. Models with CTI250 material are also available.  
Contact your OMRON representative for more details.  
116  
PTeCxBt Power Relay – G2R  
Model Number Legend  
-
G2R  
-
-
VDC  
1
2
3
4
5
6
7
8
9
1. Relay Function  
None: Single-side stable  
K: Double-winding latching  
6. Terminals  
None: Straight PCB  
T: Quick-connect (upper bracket mounting)  
2. Number of Poles  
7. Classification  
None: General-purpose  
1:  
1 pole  
2:  
2 poles  
E:  
H:  
High-capacity  
High-sensitivity  
3. Contact Form  
8. Safety Standards  
None: PDT  
None: UL/CSA/EN/SEV/TÜV  
A:  
PST-NO  
SKVD: UL/CSA/EN/SEV/TÜV/SEMKO  
4. Contact Type  
None: Single  
9. Rated Coil Voltage  
Z:  
Bifurcated  
Refer to Coil Ratings  
5. Enclosure Ratings  
None: Flux protection  
4:  
Fully sealed  
Specifications  
Coil Ratings  
Rated voltage  
12 VAC  
24 VAC  
100/(110) VAC 120 VAC 200/(220)VAC 220 VAC 230 VAC  
240 VAC  
4.7 mA  
3.8 mA  
30,000 Ω  
65.5  
93 mA  
75 mA  
65 Ω  
0.19  
46.5 mA 11 mA  
9.3 mA  
7.5 mA  
6,500 Ω  
21  
5.5 mA  
5.1 mA  
4.7 mA  
3.8 mA  
Rated Current 50Hz  
60Hz  
37.5 mA 9/(10.6) mA  
4.5 (5.3) mA 4.1 mA  
Coil resistance  
260 Ω  
0.81  
4,600 Ω  
13.34  
20,200 Ω  
51.3  
25,000 Ω 26,850  
Coil inductance Armature OFF  
(H) (ref. value) Armature ON  
Must operate voltage  
Must release voltage  
Max. voltage  
57.5  
117  
62  
0.39  
1.55  
26.84  
42  
102  
124  
131  
80% max. of rated voltage  
30% min. of rated voltage  
140% of rated voltage (at 23°C)  
Power consumption  
Approx. 0.9 VA at 60 Hz (approx. 0.7 VA at 60 Hz)  
Rated voltage  
5 VDC  
106 mA  
47 Ω  
6 VDC  
88.2 mA  
68 Ω  
12 VDC  
43.6 mA  
275 Ω  
1.15  
24 VDC  
21.8 mA  
1,100 Ω  
4.27  
48 VDC  
100 VDC  
Rated current (50/60Hz)  
Coil resistance  
11.5 mA  
4,170 Ω  
13.86  
5.3 mA  
18,860 Ω  
67.2  
0.20  
0.28  
Coil inductance Armature OFF  
(H) (ref. value) Armature ON  
Must operate voltage  
Must release voltage  
Max. voltage  
0.39  
0.55  
2.29  
8.55  
27.71  
93.2  
70% max. of rated voltage  
15% min. of rated voltage  
170% of rated voltage (at 23°C)  
Approx. 0.53 W  
Power consumption  
117  
TPeCxBt Power Relay – G2R  
High-sensitivity Relays  
Rated voltage  
5 VDC  
6 VDC  
60 mA  
12 VDC  
30 mA  
24 VDC  
15 mA  
48 VDC  
7.5 mA  
Rated current (50/60Hz)  
(see Note. 1)  
71.4 mA  
Coil resistance (see Note. 1) 70 Ω  
Coil inductance Armature OFF 0.37  
(H) (ref. value) Armature ON 0.75  
100 Ω  
0.53  
400 Ω  
2.14  
1,600 Ω  
7.80  
6,400 Ω  
31.20  
1.07  
4.27  
15.60  
62.40  
Must operate voltage  
Must release voltage  
Max. voltage  
70% max. of rated voltage  
15% min. of rated voltage  
170% of rated voltage (at 23°C)  
Approx. 0.36 W  
Power consumption  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of +15%  
/–20% (AC rated  
current) or 10% (DC coil resistance)  
2. Operating characteristics are measured at a coil temperature of 23°C  
3. Depending on the type of relay, some relays do not have coil specifications. Contact your Omron representative for more  
details.  
Double-winding Latching Relays  
Rated voltage  
Set Coil  
5 VDC  
167 mA  
30 Ω  
6 VDC  
138 mA  
43.5 Ω  
0.104  
12 VDC  
70.6 mA  
170 Ω  
0.42  
24 VDC  
34.6 mA  
694 Ω  
1.74  
Rated current (see note 1.)  
Coil resistance (see note 1.)  
Coil inductance Armature OFF  
0.073  
0.146  
119 mA  
42 Ω  
(H) (ref. value)  
Armature ON  
0.208  
0.83  
3.43  
Reset Coil  
Rated current  
Coil resistance  
100 mA  
60 Ω  
50 mA  
240 Ω  
0.018  
0.036  
25 mA  
960 Ω  
0.079  
0.148  
Coil inductance Armature OFF  
(H) (ref. value) Armature ON  
0.003  
0.006  
0.005  
0.009  
Must set voltage  
70% max. of rated voltage  
70% max. of rated voltage  
140% of rated voltage (at 23°C)  
Must reset voltage  
Max. voltage  
Power consumption  
Set coil: Approx. 850 mW; Reset coil: Approx. 600 mW  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.  
2. Operating characteristics are measured at a coil temperature of 23°C.  
118  
PTeCxBt Power Relay – G2R  
Contact Ratings  
PCB/Flux Protection, Plug-in, Quick-connect Terminal Relays  
Item  
Number of poles  
Load  
General-purpose, quick-connect terminal  
High-capacity  
1 pole  
2 poles  
1 pole  
Resistive load  
Inductive load Resistive load  
Inductive load  
(cosϕ = 0.4;  
L/R = 7 ms)  
Resistive load  
Inductive load  
(cosϕ = 0.4;  
L/R = 7 ms)  
(cosϕ = 1)  
(cosϕ = 0.4;  
(cosϕ = 1)  
(cosϕ = 1)  
L/R = 7 ms)  
Rated Load  
10 A at 250 VAC;  
10 A at 30 VDC  
7.5 A at 250  
VAC;  
5 A at 250 VAC; 2 A at 250 VAC; 16 A at 250 VAC; 8 A at 250 VAC;  
5 A at 30 VDC  
3 A at 30 VDC  
16 A at 30 VDC 8 A at 30 VDC  
5 A at 30 VDC  
Contact material  
AgSnIn  
10 A  
Rated carry current  
5 A  
16 A  
Max. switching voltage 380 VAC, 125 VDC  
Max. switching current 10 A  
380 VAC, 125 VDC  
5 A  
380 VAC, 125 VDC  
16 A  
Max. switching power 2,500 VA,  
1,875 VA,  
150 W  
1,250 VA,  
150 W  
500 VA,  
90 W  
4,000 VA,  
480 W  
2,000 VA,  
240 W  
300 W  
Failure rate  
100 mA at 5 VDC  
10 mA at 5 VDC  
100 mA at 5 VDC  
(reference value)  
Note: 1. P level: λ = 0.1 x 10-6/operation.  
60  
PCB/Flux Protection Relays  
Item  
Number of poles  
Load  
Bifurcated contacts  
High-sensitivity  
1 pole  
1 pole  
2 poles  
Resistive load  
Inductive load  
(cosϕ = 0.4;  
L/R = 7 ms)  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4;  
L/R = 7 ms)  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4;  
L/R = 7 ms)  
(cosϕ = 1)  
Rated Load  
5 A at 250 VAC; 2 A at 250 VAC; 5 A at 250 VAC; 2 A at 250 VAC; 3 A at 250 VAC; 1 A at 250 VAC;  
5 A at 30 VDC  
3 A at 30 VDC  
5 A at 30 VDC  
3 A at 30 VDC  
3 A at 30 VDC  
1.5 A at 30 VDC  
Rated carry current  
5 A  
5 A  
3 A  
Max. switching voltage 380 VAC, 125 VDC  
Max. switching current 5 A  
380 VAC, 125 VDC  
5 A  
380 VAC, 125 VDC  
3 A  
Max. switching power 1,250 VA,  
500 VA,  
90 W  
1,250 VA,  
150 W  
500 VA,  
90 W  
750 VA,  
90 W  
250 VA,  
45 W  
150 W  
Failure rate  
1 mA at 5 VDC  
100 mA at 5 VDC  
10 mA at 5 VDC  
(reference value)  
Note: P level: λ = 0.1 x 10-6/operation.  
60  
119  
TPeCxBt Power Relay – G2R  
PCB/Fully Sealed Relays  
Item  
General-purpose (single contact)  
Bifurcated contact  
Number of poles  
Load  
1 pole  
2 poles  
1 pole  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4;  
L/R = 7 ms)  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4;  
L/R = 7 ms)  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4;  
L/R = 7 ms)  
Rated Load  
8 A at 250 VAC; 6 A at 250 VAC; 4 A at 250 VAC; 1.5 A at 250 VAC; 5 A at 250 VAC; 2 A at 250 VAC;  
8 A at 30 VDC  
4 A at 30 VDC  
4 A at 30 VDC  
2.5 A at 30 VDC 5 A at 30 VDC  
3 A at 30 VDC  
Rated carry current  
8 A  
4 A  
5 A  
Max. switching voltage 380 VAC, 125 VDC  
Max. switching current 8 A  
380 VAC, 125 VDC  
4 A  
380 VAC, 125 VDC  
5 A  
Max. switching power 2,000 VA,  
1,500 VA,  
120 W  
1,000 VA,  
120 W  
375 VA,  
75 W  
1,250 VA,  
150 W  
500 VA,  
90 W  
240 W  
Failure rate  
100 mA at 5 VDC  
10 mA at 5 VDC  
1 mA at 5 VDC  
(reference value)  
Note: P level: λ = 0.1 x 10-6/operation.  
60  
Latching Relays  
Number of poles  
1 pole  
Inductive load  
2 poles  
Load  
Resistive load  
(cosϕ = 1)  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4;  
L/R = 7 ms)  
(cosϕ = 0.4;  
L/R = 7 ms)  
Rated Load  
5 A at 250 VAC;  
5 A at 30 VDC  
3.5 A at 250 VAC;  
2.5 A at 30 VDC  
3 A at 250 VAC;  
3 A at 30 VDC  
1.5 A at 250 VAC;  
2 A at 30 VDC  
Rated carry current  
5 A  
3 A  
Max. switching voltage 380 VAC, 125 VDC  
Max. switching current 5 A  
380 VAC, 125 VDC  
3 A  
Max. switching power 1,250 VA, 150 W  
875 VA, 75 W  
750 VA, 90 W  
10 mA at 5 VDC  
375 VA, 60 W  
Failure rate  
100 mA at 5 VDC  
(reference value)  
Note: P level: λ = 0.1 x 10-6/operation.  
60  
120  
PTeCxBt Power Relay – G2R  
Characteristics  
Standard Relays  
Item  
1 Pole  
2 Poles  
Contact resistance  
Operate (set) time  
30 mΩ max. (high-capacity type: 100 mΩ max.) 50 mΩ max.  
15 ms max  
Release (reset) time  
Max. operating frequency  
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)  
Mechanical: 18,000 operations/hr  
Electrical: 1,800 operations/hr (under rated load)  
Insulation resistance  
1,000 MΩ min. (at 500 VDC)  
Impulse withstand voltage  
10KV 1*40µsec  
Insulation  
Distance  
Creepage (Typ) 10.0 mm  
Clearance (Typ) 9.3 mm  
Tracking Resistance (CTI)  
Dielectric strength  
175 V  
5,000 VAC, 50/60 Hz for 1 min  
between coil and contacts*;  
5,000 VAC, 50/60 Hz for 1 min  
between coil and contacts*;  
1,000 VAC, 50/60 Hz for 1 min  
between contacts of same polarity  
3,000 VAC, 50/60 Hz for 1 min  
between contacts of different polarity  
1,000 VAC, 50/60 Hz for 1 min  
between contacts of same polarity  
Vibration resistance  
Shock resistance  
Endurance  
Destruction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)  
Destruction: 1,000 m/s2  
Malfunction: 200 m/s2 when energized; 100 m/s2 when not energized  
Mechanical: AC coil: 10,000,000 operations min.;  
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)  
Electrical:100,000 operations min. (at 1,800 operations/hr under rated load)  
Ambient temperature  
Ambient humidity  
Weight  
Operating: -40˚C to 70˚C (with no icing)  
Operating: 5% to 85%  
Approx. 17 g  
Note: Values in the above table are initial values.  
121  
TPeCxBt Power Relay – G2R  
Double-winding Latching Relays  
Item  
1 Pole  
2 Poles  
Contact resistance  
Set time  
30 mΩ max.  
50 mΩ max.  
20 ms max  
20 ms max.  
30 ms max.  
Reset time  
Min. set/reset signal width  
Max. operating frequency  
Mechanical: 18,000 operations/hr  
Electrical: 1,800 operations/hr (under rated load)  
Insulation resistance  
Dielectric strength  
1,000 MΩ min. (at 500 VDC)  
5,000 VAC, 50/60 Hz for 1 min  
between coil and contacts*;  
1,000 VAC, 50/60 Hz for 1 min  
between contacts of same pole;  
1,000 VAC, 50/60 Hz for 1 min  
between set and reset coil  
5,000 VAC, 50/60 Hz for 1 min  
between coil and contacts*;  
3,000 VAC, 50/60 Hz for 1 min  
between contacts of different poles  
1,000 VAC, 50/60 Hz for 1 min  
between contacts of same pole  
1,000 VAC, 50/60 Hz for 1 min  
between set and reset coil  
Vibration resistance  
Shock resistance  
Destruction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)  
Destruction: 1,000 m/s2 (approx. 100G)  
Malfunction: Set: 500 m/s2 (approx. 50G); 200 m/s2 (approx. 20G)  
Reset: 100 m/s2 (approx. 10G)  
Endurance  
Mechanical: 10,000,000 operations min (at 18,000 operations/hr)  
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load)  
Ambient temperature  
Ambient humidity  
Weight  
Operating: -40˚C to 70˚C (with no icing)  
Operating: 5% to 85%  
Approx. 17 g (Quick-connect type: approx. 20g)  
Note: Values in the above table are the initial values.  
122  
PTeCxBt Power Relay – G2R  
Approved Standards  
UL 508 (File No. E41643), CSA 22.2 No.14 (File No. LR31928)  
Model  
Contact form  
SPDT  
Coil ratings  
3 to 110 VDC  
Contact ratings  
10 A, 30 VDC (resistive)  
G2R-1  
G2R-14  
G2R-1-H  
G2R-1-S  
G2R-1-T  
3 to 240 VAC  
10 A, 250 VAC (general use)  
TV-3 (NO contact only)  
G2R-1A  
SPST-NO  
G2R-1A4  
G2R-1A-H  
G2R-1A-S  
G2R-1A-T  
16 A, 30 VDC (resistive, NO contact only)  
16 A, 250 VAC (general use, NO contact only)  
TV-3 (NO contact only); (1/3 hp, 120 VAC For UL)  
G2R-1-E  
SPDT  
G2R-1A-E  
SPST-NO  
DPDT  
G2R-2  
5 A, 30 VDC (resistive)  
5 A, 250 VAC (general use)  
TV-3 (NO contact only)  
G2R-24  
G2R-2-H  
G2R-2-S  
G2R-2A  
DPST-NO  
SPST-NO  
G2R-2A4  
G2R-2A-H  
G2R-2A-S  
G2R-1A-ASI  
10 A, 30 VDC (resistive)  
10 A, 250 VAC (general use)  
TV-5/TV-8 (NO contact only), (For UL)  
TV-8 (NO contact only); 1/4 hp, 125 VAC (For CSA)  
123  
TPeCxBt Power Relay – G2R  
SEV  
Contact form  
Coil ratings  
Contact ratings  
1 pole  
3 to 110 VDC  
3 to 240 VAC  
16 A, 250 VAC1 (AgSnIn contact)  
16 A, 30 VDC1 (AgSnIn contact)  
10 A, 250 VAC1  
5 A, 250 VAC3  
10 A, 30 VDC1  
2 poles  
5 A, 250 VAC1  
2 A, 380 VAC1  
5 A, 30 VDC1  
SEMKO  
Contact form  
Coil ratings  
Contact ratings  
1 pole  
3 to 110 VDC  
3 to 240 VAC  
10/80 A, 250 VAC  
3/100 A, 250 VAC  
16/128 A, 250 VAC (AgSnIn contact)  
2 poles  
5/40 A, 250 VAC  
TÜV (EN61810-1)  
Contact form  
Coil ratings  
Contact ratings  
1 pole  
3 to 110 VDC, 6 VAC to 240 VAC  
(for Standard coil)  
10 A, 250 VAC (cosϕ = 1.0)  
10 A, 30 VDC (0 ms)  
3 to 48 VDC (for K, U coil)  
3 to 70 VDC (for H coil)  
16 A, 250 VAC (cosϕ = 1.0)  
(AgSnIn contact)  
2 poles  
8 A, 250 VAC (cosϕ = 0.4)  
5 A, 250 VAC (cosϕ =1.0)  
5 A, 30 VDC (0 ms)  
2.5 A, 250 VAC (cosϕ = 0.4)  
EN 61810-1 (VDE)  
Contact form  
Coil ratings  
Contact ratings  
1 pole  
5, 6, 9, 12, 18, 24, 48, 60, 100, 110 VDC  
12, 18, 24, 48, 50, 100/(110), 110, 120,  
200/(220), 220, 230, 240 VAC  
10 A, 250 VAC (cosϕ = 1.0)  
10 A, 30 VDC (0 ms)  
16 A, 250 VAC (cosϕ = 1.0)  
2 poles  
5, 6, 9, 12, 18, 24, 48, 60, 100, 110 VDC  
12, 18, 24, 48, 50, 100/(110), 110, 120,  
200/(220), 220, 230, 240 VAC  
5 A, 250 VAC (cosϕ =1.0)  
5 A, 30 VDC (0 ms)  
124  
PTeCxBt Power Relay – G2R  
Engineering Data  
Maximum Switching Power  
Flux Protection/Plug-in Relays  
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T  
G2R-1-E, G2R-1A-E  
G2R-1Z, G2R-1AZ  
AC inductive load  
AC  
resistive load  
AC inductive load  
AC  
AC inductive load  
AC  
resistive load  
resistive load  
DC  
resistive load  
DC  
DC inductive load  
(L/R = 7 ms)  
resistive load  
DC inductive load  
(L/R = 7 ms)  
DC inductive load  
(L/R = 7 ms)  
DC  
resistive load  
Switching voltage (V)  
Switching voltage (V)  
Switching voltage (V)  
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A  
G2R-2-H, G2R-2A-H  
AC inductive load  
AC  
AC inductive load  
resistive load  
AC  
resistive load  
DC  
resistive load  
DC  
resistive load  
DC inductive load  
(L/R = 7 ms)  
DC inductive load  
(L/R = 7 ms)  
Switching voltage (V)  
G2RK-1A, G2RK-1  
Switching voltage (V)  
G2RK-2A, G2RK-2  
AC  
resistive load  
AC inductive load  
AC  
AC inductive load  
resistive load  
DC  
DC inductive load  
(L/R = 7 ms)  
resistive load  
DC inductive load  
(L/R = 7 ms)  
DC  
resistive load  
Switching voltage (V)  
Switching voltage (V)  
125  
TPeCxBt Power Relay – G2R  
Fully Sealed Relays  
G2R-14, G2R-1A4  
G2R-24, G2R-2A4  
G2R-1Z4, G2R-1AZ4  
AC inductive load AC  
AC inductive load  
(cosφ = 0.4)  
AC  
(cosφ = 0.4)  
resistive load  
resistive load  
AC  
AC inductive load  
(cosφ = 0.4)  
resistive load  
DC  
DC inductive load  
(L/R = 7 ms)  
DC  
resistive load  
resistive load  
DC resistive load  
DC inductive load  
(L/R = 7 ms)  
DC inductive load  
(L/R = 7 ms)  
Switching voltage (V)  
Switching voltage (V)  
Switching voltage (V)  
Endurance  
Flux Protection/Plug-in Relays  
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T  
G2R-1-E, G2R-1A-E  
G2R-1Z, G2R-1AZ  
5,000  
5,000  
10,000  
250-VAC/30-VDC  
1,000  
500  
resistive load  
5,000  
3,000  
1,000  
500  
250-VAC (cosφ = 0.4)  
/30-VDC (L/R = 7 ms)  
inductive load  
250-VAC inductive load  
30-VDC inductive load (L/R = 7 ms)  
(cosφ = 0.4)  
250-VAC/30-VDC  
resistive load  
1,000  
500  
250-VAC/30-VDC  
resistive load  
100  
50  
100  
50  
300  
30-VDC inductive load (L/R = 7ms)  
250-VAC inductive  
load (cosφ = 0.4)  
100  
Switching current (A)  
Switching current (A)  
Switching current (A)  
G2R-1-H, G2R-1A-H, G2R-2  
G2R-2A  
G2R-2-H, G2R-2A-H  
5,000  
10,000  
5,000  
3,000  
1,000  
250-VAC/30-VDC  
resistive load  
30-VDC  
30-VDC inductive load (L/R = 7 ms)  
1,000  
500  
500  
250-VAC/30-VDC  
resistive load  
inductive load  
(L/R = 7 ms)  
300  
100  
50  
100  
50  
30  
250-VAC  
inductive load  
(cosφ = 0.4)  
250-VAC  
inductive load  
(cosφ = 0.4)  
Switching current (A)  
Switching current (A)  
126  
PTeCxBt Power Relay – G2R  
Engineering Data (cont.)  
G2RK-1A, G2RK-1  
G2RK-2A, G2RK-2  
10,000  
5,000  
5,000  
250-VAC/30-VDC  
resistive load  
30-VDC inductive  
load (L/R = 7 ms)  
250-VAC/30-VDC  
resistive load  
1,000  
500  
1,000  
500  
250-VAC inductive  
load (cosφ = 0.4)  
250-VAC inductive  
load (cosφ = 0.4)  
100  
50  
100  
30-VDC  
50  
inductive load  
(L/R = 7ms)  
Switching current (A)  
Switching current (A)  
Fully sealed Relays  
G2R-14, G2R-1A4  
G2R-24, G2R-2A4  
G2R-1Z4, G2R-1AZ4  
5,000  
5,000  
5,000  
1,000  
30-VDC inductive  
load (L/R = 7 ms)  
500  
1,000  
500  
250-VAC/30-VDC  
resistive load  
1,000  
500  
250-VAC/30-VDC  
resistive load  
250-VAC/30-VDC  
resistive load  
100  
50  
250-VAC inductive  
load (cosφ = 0.4)  
30-VDC inductive load  
(L/R = 7 ms)  
250-VAC inductive  
load (cosφ = 0.4)  
100  
100  
250-VAC inductive load (cosφ = 0.4)  
30-VDC inductive load (L/R = 7ms)  
Switching current (A)  
50  
50  
Switching current (A)  
Switching current (A)  
Ambient Temperature vs Maximum Coil Voltage  
DC coil  
AC coil  
Note: The maximum coil voltage refers to the maxi-  
mum value in a varying range of operating  
power voltage, not a continuous voltage.  
Ambient temperature (°C)  
127  
TPeCxBt Power Relay – G2R  
Dimensions  
Note: 1. All units are in millimetres unless otherwise indicated.  
2. Orientation marks are indicated as follows:  
Relays with PCB Terminals  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Mounting Holes  
(Bottom View)  
Tolerance: 0.1  
SPDT Relays  
G2R-1, G2R-1Z, G2R-1-H  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
3.5 3.5  
(2.7)  
25.5 max.  
(25.3)*  
1
5
3
2
7.5  
(0.3)  
Five, 1.3-dia.  
holes  
4
(2.1)  
20  
0.5  
0.5**  
1
4
The illustration  
shows the  
G2R-1.  
0.3  
(No coil polarity)  
0.16  
*Average value  
**0.3 (-H Type)  
SPST-NO Relays  
G2R-1A, G2R-1AZ, G2R-1A-H  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
3.5  
(2.7)  
1
3
25.5 max.  
(25.3)*  
7.5  
Four, 1.3-dia.  
holes  
4
(0.3)  
5
(2.1)  
20  
The illustration  
0.3  
0.5**  
1
shows the  
G2R-1A.  
4
(No coil polarity)  
0.16  
*Average value  
**0.3 (-H Type)  
SPDT/High-capacity Relays  
G2R-1-E  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
Eight, 1.3-dia.  
holes  
5
5
(2.7)  
1
8
2
3
6
4
5
25.5 max.  
7.5  
(25.3)*  
(0.3)  
7
(2.1)  
(2.1)  
15  
0.5  
0.3  
1
4
0.3  
0.16  
*Average value  
(No coil polarity)  
SPST-NO/High-capacity Relays  
G2R-1A-E  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
Six, 1.3-dia.  
holes  
5
(2.7)  
25.5 max.  
1
8
3
6
4
5
(25.3)*  
(0.3)  
7.5  
(2.1)  
(2.1)  
20  
0.3  
4
0.3  
1
(No coil polarity)  
0.16  
*Average value  
128  
PTeCxBt Power Relay – G2R  
Relays with PCB Terminals  
SPDT Relays  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Mounting Holes  
(Bottom View)  
G2R-14, G2R-1Z4  
13.5 max.  
(12.9)*  
Tolerance: ±0.1  
29 max.  
(28.6)*  
3.5 3.5  
25.5 max.  
(24.8)*  
(2.7)  
1
5
3
2
7.5  
Five, 1.3-dia.  
holes  
4
(2.1)  
20  
1
0.5  
0.5  
4
0.3  
(No coil polarity)  
0.16  
*Average value  
SPST-NO Relays  
G2R-1A4, G2R-1AZ4  
13.5 max.  
(12.9)*  
29 max.  
(28.6)*  
3.5  
(2.7)  
1
3
25.5 max.  
(24.8)*  
7.5  
Four, 1.3-dia.  
holes  
4
5
(2.1)  
20  
0.5  
1
4
(No coil polarity)  
0.3  
0.16  
*Average value  
Relays with PCB Terminals  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Mounting Holes  
(Bottom View)  
DPDT Relays  
G2R-2, G2R-2-H  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
Tolerance: 0.1  
Eight, 1.3-dia.  
holes  
5
5
25.5 max.  
(2.7)  
(25.2)*  
1
8
2
7
3
6
4
5
(0.3)  
7.5  
0.5  
(2.1)  
(2.1)  
0.5  
15  
1
0.3  
4
0.15  
*Average value  
(No coil polarity)  
DPST-NO Relays  
G2R-2A, G2R-2A-H  
13 max.  
(12.7)*  
29 max.  
(28.8)*  
Six, 1.3-dia.  
holes  
5
(2.7)  
25.5 max.  
(25.2)*  
1
3
4
7.5  
(0.3)  
6
5
8
(2.1)  
(2.1)  
20  
0.5  
1
4
0.3  
0.15  
(No coil polarity)  
*Average value  
DPDT Relays  
DPDT Relays  
G2R-24  
13.5 max.  
(12.8)*  
29 max.  
(28.6)*  
Eight, 1.3-dia.  
holes  
5
5
(2.7)  
25.5 max.  
(24.7)*  
1
8
2
3
6
4
7.5  
7
5
(2.1)  
(2.1)  
15  
0.5  
0.5  
1
4
0.3  
0.15  
*Average value  
(No coil polarity)  
129  
TPeCxBt Power Relay – G2R  
DPST-NO Relays  
G2R-2A4  
13.5 max.  
(12.8)*  
29 max.  
(28.6)*  
Six, 1.3-dia.  
holes  
5
(2.7)  
25.5 max.  
(24.7)*  
1
8
3
6
4
5
7.5  
0.5  
1
(2.1)  
(2.1)  
20  
4
0.3  
0.15  
*Average value  
(No coil polarity)  
Double-winding Latching Relays with PCB Terminals  
13 max.  
(12.8)*  
SPDT Relays  
G2RK-1  
29 max.  
(28.8)*  
3.5 3.5  
5
(2.7)  
4
1
2
R
6
3
25.5 max.  
(25.2)*  
-
-
7.5  
S
7
Seven, 1.3-dia.  
holes  
(0.3)  
+
+
5
(2.1)  
20  
0.5  
1
0.3  
1
4
(After confirming coil  
polarity, wire correctly.)  
*Average value  
Double-winding Latching Relays with PCB Terminals  
13 max.  
29 max.  
SPST-NO Relays  
G2RK-1A  
Mounting Holes  
(Bottom View)  
Tolerance: 0.1  
(28.8)*  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
(12.8)*  
25.5 max.  
(25.2)*  
3.5  
5
(0.3)  
(2.7)  
1
S
7
2
R
6
4
-
-
7.5  
+
+
Six, 1.3-dia.  
holes  
5
1
0.5  
0.3  
1
4
0.16  
*Average value  
(2.1)  
20  
13 max.  
(12.8)*  
29 max.  
(28.8)*  
(After confirming coil  
polarity, wire correctly.)  
DPDT Relays  
G2RK-2  
Eight, 1.3-dia.  
holes  
5
5
5
25.5 max.  
(25.2)*  
(2.7)  
(2.7)  
3
8
4
5
6
1
2
(0.3)  
-
-
S
10  
R
9
7.5  
+
+
7
1
0.18  
0.15  
(2.1)  
4
10  
0.3  
0.18  
1
(2.1)  
*Average value  
(After confirming coil  
polarity, wire correctly.)  
DPST-NO Relays  
G2RK-2A  
13 max.  
29 max.  
Six, 1.3-dia.  
holes  
5
5
4
7
5
1
-
2
(2.7)  
-
25.5 max.  
(0.3)  
S
R
9
+
+
7.5  
6
10  
(2.7)  
(2.1)  
15  
(2.1)  
1
0.3  
1
0.18  
0.15  
4
(After confirming coil  
polarity, wire correctly.)  
130  
PTeCxBt Power Relay – G2R  
Relays with Quick-connect Terminals  
Terminal Arrangement/Internal Connections  
(Bottom View)  
30.5 max.  
(29.7)*  
SPDT Relays  
G2R-1-T  
7.5  
1
2
4
3
5.2  
17.4  
5.2  
5
Five, 1.3-dia. holes  
(No coil polarity)  
4.75  
0.5  
Mounting Holes (Bottom View)  
Tolerance: 0.1  
8.5  
38  
Two M3 or two 3.5 dia.  
29.5 max.  
2.5  
*Average value  
45 max.  
(43.9)*  
14 max.  
(13.1)*  
30.5 max.  
(29.7)*  
Terminal Arrangement/Internal Connections  
(Bottom View)  
SPST-NO Relays  
G2R-1A-T  
7.5  
1
4
3
5.2  
5
17.4  
Five, 1.3-dia. holes  
(No coil polarity)  
4.75  
0.5  
8.5  
Mounting Holes (Bottom View)  
38  
Two M3 or two 3.5 dia.  
29.5 max.  
2.5  
Note: Model number of quick-connect terminal  
45 max.  
(43.9)*  
14 max.  
(13.1)*  
is 187.  
*Average value  
Precautions  
Mounting  
When mounting a number of relays on a PCB, be sure to provide  
a minimum mounting space of 5 mm between the two juxtaposed  
relays as shown below.  
The above minimum mounting space is necessary due to mutual  
thermal interference generated by the relays. This restriction may  
be ignored, however, depending on the operating conditions of  
the relays. Consult OMRON for details.  
There is no restriction on the mounting direction of each relay on  
the PCB.  
When using this circuit, confirm the set and reset states and then  
take into account the circuit constant.  
5 mm min.  
5 mm min.  
CAT. No. K013-E2-12A-X  
131  

相关型号:

G2R-1A-E-AC200/220

Power/Signal Relay
OMRON

G2R-1A-E-AC220

Power/Signal Relay, SPST, Momentary, 900mW (Coil), 16A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Through Hole-Straight Mount
OMRON

G2R-1A-E-ASI24VDC

Power/Signal Relay, SPST, Momentary, 0.022A (Coil), 24VDC (Coil), 530mW (Coil), 16A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G2R-1A-E-DC110

Power/Signal Relay, SPST, Momentary, 0.005A (Coil), 110VDC (Coil), 530mW (Coil), 16A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G2R-1A-E-DC12

Power/Signal Relay, 1 Form A, SPST, Momentary, 0.044A (Coil), 12VDC (Coil), 530mW (Coil), 16A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount
OMRON

G2R-1A-E-DC24

Creepage distance of 8.0 mm min. between coil and con tact.
OMRON

G2R-1A-E-DC3

Power/Signal Relay, SPST, Momentary, 0.176A (Coil), 3VDC (Coil), 530mW (Coil), 16A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G2R-1A-E-DC5

Power/Signal Relay, 1 Form A, SPST, Momentary, 0.106A (Coil), 5VDC (Coil), 530mW (Coil), 16A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount
OMRON

G2R-1A-E-T130-DC24

Creepage distance of 8.0 mm min. between coil and con - tact.
OMRON

G2R-1A-E100AC

Electromechanical Relay, SPST, Latched, 16A (Contact), 30VDC (Contact), AC/DC Output
OMRON

G2R-1A-E12AC

Electromechanical Relay, SPST, Latched, 16A (Contact), 30VDC (Contact), AC/DC Output
OMRON

G2R-1A-E200AC

Electromechanical Relay, SPST, Latched, 16A (Contact), 30VDC (Contact), AC/DC Output
OMRON