G2R-2-S-DC6(S) [OMRON]
Power/Signal Relay, SPDT, Momentary, 0.087A (Coil), 6VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT;型号: | G2R-2-S-DC6(S) |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay, SPDT, Momentary, 0.087A (Coil), 6VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT 光电二极管 |
文件: | 总12页 (文件大小:820K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
General-purpose Relay
G2RS-(S)
Slim and Space-saving Power Plug-in Relay
• Lockable test button models now available.
• Built-in mechanical operation indicator.
• Provided with nameplate.
• AC type is equipped with a coil-disconnection self-
diagnostic function (LED type).
• High switching power (1-pole: 10 A).
• Environment-friendly (Cd, Pb free).
• Wide range of Sockets also available.
• RoHS Compliant.
LR
Model Number Structure
■ Model Number Legend
G2R -
-
- (S)
1
2
3
4
5
6
7
1. Relay Function
5. Terminals
Blank:General-purpose
S:
Plug-in
2. Number of Poles
6. Classification
Blank:General-purpose
1:
2:
1 pole
2 poles
N:
D:
LED indicator
Diode
3. Contact Form
Blank:SPDT
4. Contact Type
Blank:Single
ND: LED indicator and diode
NI: LED indicator with test button
NDI: LED indicator and diode with test button
7. Rated Coil Voltage
Ordering Information
■ List of Models
Classification
Enclosure
rating
Coil ratings
AC/DC
Contact form/Model
SPDT DPDT
Plug-in terminal
General-purpose
Unsealed
G2R-1-S
G2R-2-S
LED indicator
G2R-1-SN
G2R-1-SNI
G2R-1-SD
G2R-1-SND
G2R-1-SNDI
G2R-2-SN
G2R-2-SNI
G2R-2-SD
G2R-2-SND
G2R-2-SNDI
LED indicator with test button
Diode
DC
LED indicator and diode
LED indicator and diode with test button
Note: When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
New model
Example: G2R-1-S DC12 (S)
Rated coil voltage
General-purpose Relay G2RS-(S)
267
■ Accessories (Order Separately)
Connecting Sockets
Applicable Relay model
Track/surface-mounting Socket
Back-mounting Socket
Terminals Model
Screwless clamp terminal
Screw terminal
(See note.)
1 pole
P2RF-05-S
+
P2CM-S
PCB terminals
P2R-05P, P2R-057P
P2R-05A
P2RF-05-E
P2RF-05
G2R-1-S(N)(D)(ND)(NI)(NDI)
Solder terminals
2 poles
G2R-2-S(N)(D)(ND)(NI)(NDI)
P2RF-08-S
+
P2CM-S
PCB terminals
P2R-08P, P2R-087P
P2R-08A
P2RF-08-E
P2RF-08
Solder terminals
Note: 1. Use of P2CM Clips are optional. However, use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.
2. “-E” models are of finger-safe product construction. Round terminals cannot be used. Use Y-shaped terminals.
Accessories for Screwless Clamp Terminal Socket (Option)
Name
Model
Clip & Release Lever
Nameplate
P2CM-S
R99-11 Nameplate for MY
Socket Bridge
P2RM-SR (for AC), P2RM-SB (for DC)
Mounting Tracks
Applicable Socket
Description
Model
Mounting track and accessories
Mounting track
50 cm (l) x 7.3 mm (t) PFP-50N
1 m (l) x 7.3 mm (t)
1 m (l) x 16 mm (t)
PFP-100N
PFP-100N2
End plate
Spacer
PFP-M
PFP-S
P2R-P
Mounting plate*
Back-connecting Sockets
*Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
■ Coil Ratings
Rated voltage
Rated current*
Coil
resistance*
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
50 Hz
60 Hz
Armature Armature
% of rated voltage
OFF
ON
AC 24 V
110 V
43.5 mA
9.5 mA
8.6 mA
4.4 mA
3.7 mA
37.4 mA
8.2 mA
7.5 mA
3.8 mA
3.2 mA
253 Ω
0.81
1.55
80% max. 30% min. 110%
0.9 VA at 60 Hz
5,566 Ω
7,286 Ω
27,172 Ω
30,360 Ω
13.33
16.13
72.68
90.58
26.83
120 V
32.46
230 V
143.90
182.34
240 V
Rated voltage
Rated current*
Coil
resistance*
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
Armature Armature
% of rated voltage
OFF
0.25
ON
DC 6 V
12 V
87.0 mA
69 Ω
278 Ω
1,113 Ω
4,220 Ω
0.48
2.35
8.25
70% max. 15% min. 110%
0.53 W
43.2 mA
21.6 mA
11.4 mA
0.98
3.60
15.2
24 V
48 V
29.82
* The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of 10%.
268
General-purpose Relay G2RS-(S)
■ Contact Ratings
Number of poles
1 pole
Inductive load
2 poles
Inductive load
Load
Resistive load
Resistive load
(cosφ = 1)
(cosφ = 0.4; L/R = 7 ms)
(cosφ = 1)
(cosφ = 0.4; L/R = 7 ms)
Rated load
10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
Rated carry current
10 A
5 A
Max. switching voltage
Max. switching current
Max. switching capacity
440 VAC, 125 VDC
10 A
380 VAC, 125 VDC
5 A
2,500 VA,
300 W
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
Minimum permissible load
100 mA at 5 VDC
10 mA at 5 VDC
Note: P level: λ60 = 0.1 x 10-6/operation
■ Characteristics
Item
1 pole
2 poles
Contact resistance
Operate (set) time
Release (reset) time
100 mΩ max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
Max. operating
frequency
Mechanical:
Electrical:
18,000 operations/hr
1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
same polarity
Vibration resistance
Shock resistance
Destruction:
Malfunction:
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction:
Malfunction:
1,000 m/s2
200 m/s2 when energized; 100 m/s2 when not energized
Service life
Mechanical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
Electrical:
Ambient temperature Operating:
–40°C to 70°C (with no icing or condensation)
Ambient humidity
Weight
Operating:
5% to 85%
Approx. 21 g
Note: Values in the above table are the initial values.
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is used.
■ Approved Standards
UL Recognized (File No. E41643) - - Ambient Temp. = 40°C
IEC/VDE (EN61810)
Model Contact Coil ratings
form
Contact ratings
Cycles
Contact
form
Coil ratings
Contact ratings
Cycles
10 A, 30 VDC (resistive)
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
G2R-1-S SPDT
10 A, 250 VAC (general use) 6 x 103
TV-3 (NO contact only)
1 pole
2 poles
LR
100 x 103
100 x 103
5 to 110 VDC
5 to 240 VAC
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 250 VAC (cosφ =1.0)
G2R-2-S DPDT
6 x 103
5 A, 30 VDC (0 ms)
CSA Certified (File No. LR31928)
Model Contact Coil ratings
form
Contact ratings
Cycles
Number Coil ratings
of poles
Contact ratings
Cycles
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
G2R-1-S SPDT
10 A, 250 VAC (general use) 6 x 103
TV-3 (NO contact only)
5 to 110 VDC 7.5 A, 250 VAC (PF0.4)
5 to 240 VDC 10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
1 pole
100 x 103
5 to 110 VDC
5 to 240 VAC
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
G2R-2-S DPDT
6 x 103
5 A, 250 VAC (general use)
5 to 110 VDC 2 A, 250 VAC (PF0.4)
5 to 240 VDC 5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
2 poles
100 x 103
General-purpose Relay G2RS-(S)
269
Engineering Data
■ Maximum Switching Capacity
Plug-in Relays
G2R-1-S
G2R-2-S
100
100
AC inductive load
(cosφ = 0.4)
AC resistive
load
AC inductive load
(cosφ = 0.4)
AC resistive
load
10
10
1
DC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
1
DC inductive load
(L/R = 7 ms)
0.1
0.1
1
10
100
1000
1
10
100
1000
Switching voltage (V)
Switching voltage (V)
■ Electrical Service Life
Plug-in Relays
G2R-1-S
G2R-2-S
10,000
5,000
5,000
250-VAC/30-VDC
1,000
500
resistive load
1,000
500
250-VAC inductive load
(cosφ = 0.4)
30-VDC inductive load (L/R = 7ms)
250-VAC/30-VDC
resistive load
100
50
100
50
30-VDC inductive load (L/R = 7ms)
250-VAC
inductive load
(cosφ = 0.4)
Switching current (A)
Switching current (A)
Ambient Temperature vs. Maximum Coil Voltage
DC coil
AC coil
Note: The maximum voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
Ambient temperature (°C)
270
General-purpose Relay G2RS-(S)
Dimensions
Unit: mm (inch)
■ Relays with Plug-in Terminals
SPDT Relays
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-1-S, G2R-1-SN, G2R-1-SNI
G2R-1-SD, G2R-1-SND, G2R-1-SNDI
G2R-1-SD (DC)
G2R-1-S
1
5
1
5
13 max.
(0.51)
29 (1.14) max.
2
4
3
2
4
3
35.5 max.
(1.40)
G2R-1-SN, G2R-1-SNI (DC)
G2R-1-SN, G2R-1-SNI (AC)
20
(0.79)
1
1
D
C24V
5 (0.20)
1(0.04)
4.75
(0.19)
0.5
(0.02)
2
4
3
2
4
3
5
5
7.5 (0.29)
G2R-1-SND, G2R-1-SNDI (DC)
5.2
5.2
(0.20)
(0.20)
17.5
1
(0.69)
2
4
3
5
DPDT Relays
G2R-2-S, G2R-2-SN, G2R-2-SNI
G2R-2-SD, G2R-2-SND, G2R-2-SNDI
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-2-S
G2R-2-SD (DC)
1
2
7
3
6
4
5
1
2
7
3
4
29 max.
(1.14)
13 max.
(0.51)
8
8
6
5
35.5 max.
(1.40)
G2R-2-SN, G2R-2-SNI (AC)
G2R-2-SN, G2R-2-SNI (DC)
20
(0.79)
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
6.2
(0.29)
2.5
(0.10)
0.5
(0.02)
2.4
(0.09)
7.4
8.9
(0.29)
(0.35)
G2R-2-SND, G2R-2-SNDI (DC)
5 (0.02)
5 (0.02)
1
8
2
7
3
6
4
5
19.4
(0.76)
General-purpose Relay G2RS-(S)
271
Track/Surface Mounting Sockets
P2RF-05-S
Terminal Arrangement
(Top View)
38.2 max. (1.50)
36.5 max. (1.44)
11
14
12
32.6 (1.28)
27.6 (1.09)
22.6
(0.89)
24.5
(0.96)
35.4
(1.39)
92.0 max.
(3.62)
A1 A2
Option (with ejector and
label attached)
Standard model
28.5 (1.12)
5.3 typical
(0.21)
18.0 max.
32.6
(0.71)
(1.28)
Terminal Arrangement
(Top View)
38.2 max. (1.50)
P2RF-08-S
36.5 max.(1.44)
21 11
24 14
22 12
32.6 (1.28)
27.6 (1.09)
22.6
(0.89)
3.4 (0.13) typical
24.5
(0.96)
92.0 max.
(3.62)
35.4
(1.39)
A1 A2
Option (with ejector
and label attached)
Standard model
28.6 (1.12)
32.6 (1.28)
5.3 typical
(0.21)
18.0 max.
(0.71)
Accessories for P2RF-@-S
Socket Bridge
Clip and Release Lever
16.8
(0.66)
40.35
(1.59)
Note: The color of insulating coating indicates power type.
36
(1.42)
Model
Power
Color
P2RM-SR
P2RM-SB
AC
DC
Red
Blue
272
General-purpose Relay G2RS-(S)
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
P2RF-05-E
2 (0.08)
Five, M3.5×7
48 max.
(1.89)
3.2 (0.13)
dia. hole
(11)
4
39.5
(1.55)
35.5
(1.40)
2
(14)
3
(12)
39.5 0.1
(1.55 0.004)
85.5 max.
(3.37)
3.5 (0.14)
dia. hole
5
M3 or 3.5
(0.14) dia.
(A1)
(A2)
1
5
11.5
(0.20)
(0.45)
16.0 max.
(0.63)
61 max.
(2.40)
Note: Pin numbers in parentheses apply to DIN standard.
P2RF-08-E
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
1.5
(0.06)
2 (0.08)
3 (0.12)
48.0 max.
(1.89)
Eight, M3×8
2 (0.08)
(11)
(12)
(14)
(21)
(22)
(24)
6
3
2
4
3.2 (0.13)
dia. hole
7
5
39.5
(1.55)
35.5
(1.40)
85.5 max
(3.37)
39.5 0.1
(1.55 0.004)
8
3.5 (0.14)
dia. hole
(A1)
1
M3 or 3.5 (0.14)
dia. hole
(A2)
11.5 (0.45)
5 (0.20)
61.0 max.
(2.40)
16.0 (0.63) max.
2 (0.08)
7(0.28)
Five, M3.5 x 8
P2RF-05
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
4 (0.16)
dia. holes
4.2 (0.16)
dia. hole
71.5 max.
35.5
(2.81)
(1.40)
30 0.05
(1.18 0.002)
4
19.5 (0.77)
30 max.(1.18)
M3 or 3.2 (0.13)
dia. hole
19.5 max.
(0.77)
(0.16)
54 max.
(2.12)
P2RF-08
2 (0.08)
7 (0.28)
Eight, M3.5 x 8
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
4.2 (0.16) dia. hole
4 (0.16)
dia. holes
71.5 max.
(2.89)
35.5
(1.40)
30 0.05
(1.18 0.002)
19.5 (0.77)
30 max.(1.18)
4 (0.16)
19.5 max.
(0.77)
M3 or 3.2 (0.13)
dia. hole
54 max.
(2.12)
General-purpose Relay G2RS-(S)
273
Mounting Height of Relay with Track/Surface Mounting Sockets
P2RF-@-E
P2RF-@
62.0
(2.44)
66.5
(2.62)
67.0
(2.64)
70.5
(2.77)
P2RF-@-S
72.0
(2.83)
65.0
(2.56)
28.6
(1.12)
5.30 (0.21) typical
Back-connecting Sockets
Terminal Arrangement
(Bottom View)
Mounting Holes
14.5 max.
(0.57)
P2R-05P (1-pole)
Tolerance: 0.1
4 (0.16)
1(0.04)
7 (0.27)
4 (0.14)
Five, 1.6 (0.06)
dia. holes
6 (0.24)
4.5 (0.18)
15
35.5 max.
(1.40)
6 (0.24)
(0.59)
4.5 (0.18)
15 (0.59)
1.2 (0.05)
4 (0.16)
3.5
(0.14)
4 (0.16)
1.5 (0.06)
5 (0.20) typical
7 (0.27)
4 (0.16)
7 (2.27)
36.5 max.
(1.44)
P2R-08P (2-pole)
14.5 max.
(0.57)
Terminal Arrangement
(Bottom View)
Mounting Holes
4 (0.16)
0.3
7 (0.27)
7.5
(0.29)
Eight, 1.3 (0.05)
dia. holes
(0.01)
5 (0.20)
5 (0.20)
35.5 max.
(1.40)
5 (0.20)
20
(0.79)
1 (0.04)
5 (0.20)
20
(0.79)
2.8 (0.11)
1.5 (0.06)
7.5 (0.29)
4.3 (0.17) typical
Terminal plate thickness: 0.3 (0.01)
36.5 max. (1.44)
274
General-purpose Relay G2RS-(S)
5 (0.20)
0.3
(0.01)
14.5 max.
(0.57)
7 (0.28)
1.2 (0.05)
P2R-05A (1-pole)
Terminal Arrangement
(Bottom View)
6.7 (0.26)
3.8 (0.15)
35.5 max.
(1.40)
16.7
(0.66)
5 (0.20)
Panel Cutout
Five, 3 x 1.8-dia. holes
(0.12 x 0.07)
13.6 0.1
(0.54 0.004)
6 (0.24)
36.5 max.
(1.44)
Terminal plate thickness: 0.3
7 (0.28)
30.5 0.2
(1.20 0.008)
14.5 max.
(0.57)
7 (0.28)
1.2 (0.05)
P2R-08A (2-pole)
0.3
(0.01)
5 (0.20)
5 (0.20)
35.5 max.
(1.40)
20
Recommended thickness of
the panel is 1.6 to 2.0 mm
(0.79)
2.6 (0.10)
2.8(0.11)
1.5 (0.06)
Eight, 3 x 1.2
(0.12 x 0.05)dia. holes
7.5
(0.30)
Terminal plate thickness: 0.3
36.5 max.
(1.44)
P2R-057P 14 max. (0.55)
Terminal Arrangement
(Bottom View)
Mounting Holes
4 0.1
16.4 (0.65)
10.4
0.7 (0.03)
1(0.04)
8.7
(0.16 0.004)
(0.41)
Five, 1.6 (0.06)
dia. holes
6 0.1(0.24 0.004)
(0.34)
29.6
(1.17)
37 max.
(1.46)
4.5 0.1
(0.18 0.004)
15 0.1(0.59 0.004)
7.4 (0.29)
4 0.1 (0.16 0.004)
5 (0.20)
8.7
(0.34)
7 0.1(0.27 0.004)
41 max.
(1.61)
14 max.
(0.55)
Terminal Arrangement
(Bottom View)
Mounting Holes
16.4(0.65)
1 (0.04)
P2R-087P
10.4
7.5
(0.30)
7.5 (0.30)
Eight, 1.3 (0.05)
(0.41)
dia. holes
37 max.
29.1
(1.15)
(1.46)
5 (0.20)
5 (0.20)
20
(0.79)
7.4 (0.29)
8.9 (0.35)
8.1(0.32) typical
41 max.
(1.61)
General-purpose Relay G2RS-(S)
275
Mounting Height of Relay with Back-connecting Sockets
G2R-@P
G2R-@A
G2R-@7P
G2R Relay
G2R Relay
47.5
(1.87)
38.0
(1.50)
44.5
(1.75)
P2R-_A
Socket
P2R-_P
Socket
Mounting Tracks
PFP-100N, PFP-50N
PFP-100N2
16 (0.63)
7.3 0.15
(0.29 0.006)
4.5
4.5 (0.18)
(0.18)
24
(0.94)
27
(1.06)
29.2
(1.15)
35 0.3
(1.38 0.01)
27 0.15
1
35 0.3
15
25
25
10 (0.39)
25
25
10 (0.39)
25
25
15 (0.59)
25 (0.98)
1 (0.04)
1.5 (0.06)
15 (0.59)
25 (0.98)
1,000 (39.37)
or 500 (19.68)
15(0.59)
or 5 (0.20)
10
10
1,000
(39.37)
It is recommended to use a panel 1.6 to 2.0 mm thick.
End Plate
Spacer
16 (0.63)
10 (0.39)
6.2 (0.24)
5 (0.20)
12 (0.47)
PFP-M
PFP-S
1.8 (0.07)
1 (0.04)
35.5
(1.40)
35.3
(1.39)
50
(1.97)
34.8
(1.37)
1.8
(0.07)
44.3
(1.74)
11.5
(0.45)
1.3 (0.05)
4.8 (0.19)
10 (0.39)
M4 x 8 pan
head screw
16.5 (0.65)
Precautions
Precautions for P2RF-@-S Connection
• Do not move the screwdriver up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
!CAUTION
Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
• Do not insert the screwdriver at an angle. Doing so may break the
side of the socket and result in a short-circuit.
!CAUTION
Check that the test button is released before turning ON relay cir-
cuits.
!CAUTION
If the test button is pulled out too forcefully, it may bypass the mo-
mentary testing position and go straight into the locked position.
!CAUTION
Use an insulated tool when you operate the test button.
276
General-purpose Relay G2RS-(S)
MEMO
General-purpose Relay G2RS-(S)
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11
Specifications subject to change without notice
Printed in USA
Cat. No. X301-E-1b
General-purpose Relay G2RS-(S)
相关型号:
G2R-2-SD-12VDC
Power/Signal Relay, DPDT, Momentary, 0.044A (Coil), 12VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
G2R-2-SD-24VDC
Power/Signal Relay, DPDT, Momentary, 0.022A (Coil), 24VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
G2R-2-SD-5VDC
Power/Signal Relay, DPDT, Momentary, 0.106A (Coil), 5VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
G2R-2-SD-6VDC
Power/Signal Relay, DPDT, Momentary, 0.088A (Coil), 6VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
G2R-2-SD-DC12
Power/Signal Relay, 2 Form C, SPDT, Momentary, 0.043A (Coil), 12VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
G2R-2-SD-DC12(S)
Power/Signal Relay, SPDT, Momentary, 0.043A (Coil), 12VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
G2R-2-SD-DC24
Power/Signal Relay, 2 Form C, SPDT, Momentary, 0.022A (Coil), 24VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
G2R-2-SD-DC24(S)
Power/Signal Relay, SPDT, Momentary, 0.022A (Coil), 24VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
G2R-2-SD-DC48
Power/Signal Relay, 2 Form C, SPDT, Momentary, 0.011A (Coil), 48VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
G2R-2-SD-DC48(S)
Power/Signal Relay, SPDT, Momentary, 0.011A (Coil), 48VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
G2R-2-SD-DC6
Power/Signal Relay, 2 Form C, SPDT, Momentary, 0.087A (Coil), 6VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明