G2R-2-SN-AC230(S) [OMRON]
Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 5A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT;型号: | G2R-2-SN-AC230(S) |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay, SPDT, Momentary, 900mW (Coil), 5A (Contact), 125VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT 光电二极管 |
文件: | 总10页 (文件大小:787K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
General-purpose Relay
G2R-@-S
CSM_G2R-_-S_DS_E_2_1
Slim and Space-saving Power Plug-in Relay
■ Lockable test button models now available.
■ Built-in mechanical operation indicator.
■ Provided with nameplate.
■ AC type is equipped with a coil-disconnection self-diagnostic
function (LED type).
■ High switching power (1-pole: 10 A).
■ Environment-friendly (Cd, Pb free).
■ Wide range of Sockets also available.
LR
Model Number Structure
Model Number Legend
G2R
-
-
-
1
2
3
4
5
6
7
1. Relay Function
Blank: General-purpose
5. Terminals
S:
Plug-in
2. Number of Poles
6. Classification
1:
2:
1 pole
Blank: General-purpose
2 poles
N:
LED indicator
D:
Diode
3. Contact Form
ND:
NI:
NDI:
LED indicator and diode
LED indicator with test button
LED indicator and diode with test button
Blank: SPDT
4. Contact Type
Blank: Single
7. Rated Coil Voltage
Ordering Information
List of Models
Contact form
Enclosure
rating
Classification
Coil ratings
SPDT
G2R-1-S
DPDT
G2R-2-S
General-purpose
LED indicator
AC/DC
G2R-1-SN
G2R-1-SNI
G2R-1-SD
G2R-1-SND
G2R-1-SNDI
G2R-2-SN
G2R-2-SNI
G2R-2-SD
G2R-2-SND
G2R-2-SNDI
LED indicator with test button
Plug-in terminal
Unsealed
Diode
LED indicator and diode
LED indicator and diode with test button
DC
Note: When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
New model
Rated coil voltage
Example: G2R-1-S 12 VDC (S)
1
G2R-@-S
Accessories (Order Separately)
Connecting Sockets
Track/surface-mounting Socket
Back-mounting Socket
Applicable Relay model
Screwless clamp terminal
Screw terminal
Terminals
PCB terminals
Model
• P2RF-05S (See note.)
P2R-05P, P2R-057P
1 pole
• P2RF-05-E
• P2RF-05
+
G2R-1-S(N)(D)(ND)(NI)(NDI)
Solder terminals
PCB terminals
Solder terminals
P2R-05A
(P2CM-S (option))
• P2RF-08S (See note.)
P2R-08P, P2R-087P
P2R-08A
• P2RF-08-E
• P2RF-08
2 poles
G2R-2-S(N)(D)(ND)(NI)(NDI)
+
(P2CM-S (option))
Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.
Accessories for Screwless Clamp Terminal Socket (Option)
Name
Clip & Release Lever
Nameplate
Model
P2CM-S
R99-11 Nameplate for MY
Socket Bridge
P2RM-SR (for AC), P2RM-SB (for DC)
Mounting Tracks
Applicable Socket
Description
Mounting track
Model
50 cm (l) x 7.3 mm (t): PFP-50N
1 m (l) x 7.3 mm (t): PFP-100N
1 m (l) x 16 mm (t): PFP-100N2
Track-connecting Socket
End plate
PFP-M
PFP-S
P2R-P*
Spacer
Back-connecting Socket
Mounting plate
*Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
Coil Ratings
Must
operate
voltage
Must
release
voltage
Coil inductance (H)
Rated current*
Max.
voltage
Power
(ref. value)
Coil
Rated voltage
consumption
resistance*
(approx.)
Armature Armature
50 Hz
60 Hz
% of rated voltage
OFF
ON
24 V
110 V
43.5 mA
9.5 mA
8.6 mA
4.4 mA
3.7 mA
37.4 mA
8.2 mA
7.5 mA
3.8 mA
3.2 mA
253 Ω
0.81
1.55
5,566 Ω
7,286 Ω
27,172 Ω
30,360 Ω
13.33
16.13
72.68
90.58
26.83
AC 120 V
230 V
32.46
80% max. 30% max. 110%
0.9 VA at 60 Hz
143.90
182.34
240 V
Must
operate
voltage
Must
release
voltage
Coil inductance (H)
(ref. value)
Max.
voltage
Power
consumption
(approx.)
Coil
resistance*
Rated voltage
Rated current*
Armature Armature
% of rated voltage
OFF
ON
6 V
87.0 mA
43.2 mA
21.6 mA
11.4 mA
69 Ω
0.25
0.48
12 V
DC
278 Ω
0.98
3.60
15.2
2.35
8.25
29.82
70% max. 15% min.
110%
0.53 W
24 V
1,113 Ω
4,220 Ω
48 V
*The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of 10%.
2
G2R-@-S
Contact Ratings
Number of poles
Load
1 pole
2 poles
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
Rated load
Rated carry current
10 A
5 A
Max. switching voltage
Max. switching current
440 VAC, 125 VDC
10 A
380 VAC, 125 VDC
5 A
2,500 VA,
300 W
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
Max. switching power
Failure rate (reference value)
100 mA at 5 VDC
10 mA at 5 VDC
Note: P level: λ60 = 0.1 x 10-6/operation
Characteristics
Item
1 pole
2 poles
Contact resistance
Operate (set) time
100 mΩ max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
Release (reset) time
Max. operating
frequency
Mechanical:
Electrical:
18,000 operations/hr
1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
contacts*;
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between contacts of
same polarity
Destruction:
Malfunction:
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Vibration resistance
Shock resistance
Destruction:
Malfunction:
1,000 m/s2
200 m/s2 when energized; 100 m/s2 when not energized
Mechanical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
Endurance
Electrical:
Ambient temperature Operating:
–40°C to 70°C (with no icing or condensation)
Ambient humidity
Weight
Operating:
5% to 85%
Approx. 21 g
Note: Values in the above table are the initial values.
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is mounted.
Approved Standards
UL 508 (File No. E41643)
IEC/VDE (EN61810)
Contact
form
Oper-
ations
Contact
form
Model
Coil ratings
Contact ratings
Coil ratings
Contact ratings
Operations
10 A, 30 VDC (resistive)
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
G2R-1-S SPDT
G2R-2-S DPDT
10 A, 250 VAC (general use) 6 x 103
TV-3 (NO contact only)
1 pole
100 x 103
5 to 110 VDC
5 to 240 VAC
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
6 x 103
2 poles
100 x 103
CSA 22.2 No.0, No.14
(File No. LR31928)
LR
Number
of poles
Coil ratings
Contact ratings
Operations
Contact
form
Oper-
ations
Model
Coil ratings
Contact ratings
10 A, 250 VAC (general use)
5 to 110 VDC 7.5 A, 250 VAC (PF0.4)
5 to 240 VDC 10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
1 pole
100 x 103
10 A, 30 VDC (resistive)
G2R-1-S SPDT
G2R-2-S DPDT
10 A, 250 VAC (general use) 6 x 103
TV-3 (NO contact only)
5 to 110 VDC
5 to 240 VAC
5 A, 250 VAC (general use)
5 to 110 VDC 2 A, 250 VAC (PF0.4)
5 to 240 VDC 5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
100 x 103
6 x 103
2 poles
3
G2R-@-S
Engineering Data
Maximum Switching Power
Plug-in Relays
G2R-2-S
100
G2R-1-S
100
AC inductive load
(cosφ = 0.4)
AC resistive
load
AC inductive load
(cosφ = 0.4)
AC resistive
load
10
1
10
1
DC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
0.1
0.1
1
10
100
1000
1
10
100
1000
Switching voltage (V)
Switching voltage (V)
Endurance
Plug-in Relays
G2R-1-S
G2R-2-S
10,000
5,000
5,000
250-VAC/30-VDC
resistive load
1,000
500
1,000
500
250-VAC inductive load
(cosφ = 0.4)
30-VDC inductive load (L/R = 7ms)
250-VAC/30-VDC
resistive load
100
100
50
30-VDC inductive load (L/R = 7ms)
250-VAC
50
inductive load
(cosφ = 0.4)
Switching current (A)
Switching current (A)
Ambient Temperature vs Maximum Coil Voltage
DC coil
AC coil
Note: The maximum voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
Ambient temperature (°C)
4
G2R-@-S
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Relays with Plug-in Terminals
SPDT Relays
G2R-1-S, G2R-1-SN, G2R-1-SNI
G2R-1-SD, G2R-1-SND, G2R-1-SNDI
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-1-SD (DC)
G2R-1-S
1
1
5
29 max.
13 max.
2
4
3
5
2
4
3
G2R-1-SN, G2R-1-SNI (DC)
G2R-1-SN, G2R-1-SNI (AC)
1
1
D
C
24
V
0.5
4.75
2
4
3
2
4
3
5
5
G2R-1-SND, G2R-1-SNDI (DC)
5.2
5.2
17.5
1
2
4
3
5
DPDT Relays
G2R-2-S, G2R-2-SN, G2R-2-SNI
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-2-SD, G2R-2-SND, G2R-2-SNDI
G2R-2-S
G2R-2-SD (DC)
1
2
7
3
6
4
5
1
2
3
6
4
13 max.
29 max.
8
8
7
5
G2R-2-SN, G2R-2-SNI (AC)
G2R-2-SN, G2R-2-SNI (DC)
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
0.5
2.5
2.4
G2R-2-SND, G2R-2-SNDI (DC)
5
5
19.4
1
8
2
7
3
6
4
5
5
G2R-@-S
Track/Surface Mounting Sockets
38.2 max.
36.5 max.
P2RF-05-S
Terminal Arrangement
(Top View)
11
14
12
32.6
27.6
22.6
A1 A2
Option (with ejector and
Standard model
label attached)
(5.3)
28.5
32.6
18.0 max.
Terminal Arrangement
(Top View)
38.2 max.
P2RF-08-S
36.5 max.
21 11
24 14
22 12
32.6
27.6
22.6
(3.4)
A1 A2
Option (with ejector
and label attached)
Standard model
(5.3)
28.6
32.6
18.0 max.
Accessories for P2RF-@-S
Socket Bridge
Clip and Release Lever
Insulating coating
14
9
L
(See note 1.)
16.8
40.35
1.2 dia. conductor
6
G2R-@-S
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
P2RF-05-E
2
Five, M3.5×7
48 max.
3.2-dia.
hole
(11)
4
2
(14)
3
39.5
(12)
35.5
39.5 0.1
85.5 max.
3.5-dia.
hole
M3 or
3.5-dia.
hole
5
(A1)
(A2)
1
11.5
61 max.
16.0 max.
Note: Pin numbers in parentheses apply to DIN standard.
P2RF-08-E
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
2
1.5
Eight, M3×8
2
48.0 max.
3
(11)
(12)
(14)
(21)
(22)
(24)
6
3
2
4
3.2-dia.
hole
7
5
39.5
35.5
85.5
max.
39.5 0.1
8
3.5-dia. hole
M3 or
3.5-dia.
hole
(A1)
1
(A2)
5
11.5
61.0
max.
16.0 max.
2
P2RF-05
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
7
Five, M3.5 x 8
4-dia. holes
4.2-dia. hole
35.5
71.5 max.
30 0.05
19.5
30 max.
4
M3 or 3.2-dia.
hole
19.5 max.
54 max.
P2RF-08
2
7
Eight, M3.5 x 8
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
4.2-dia. hole
4-dia. holes
35.5
71.5 max.
30 0.05
19.5
4
30 max.
19.5 max.
M3 or 3.2-dia.
hole
54 max.
7
G2R-@-S
Mounting Height of Relay with Track/Surface Mounting Sockets
P2RF-@-E
P2RF-@
62.0
66.5
70.5
67.0
P2RF-@-S
72.0
65.0
28.6
(5.30)
Back-connecting Sockets
P2R-05P (1-pole)
Terminal Arrangement
(Bottom View)
Mounting Holes
Tolerance: 0.1
14.5 max.
4
7
1
4
Five,
6
1.6-dia.
holes
4.5
6
35.5 max.
15
4.5
15
1.2
4
3.5
1.5
4
(5)
4
7
7
36.5 max.
P2R-08P (2-pole)
Terminal Arrangement
(Bottom View)
Mounting Holes
14.5 max.
4
7
0.3
Eight, 1.3-dia. holes
7.5
5
5
5
5
35.5 max.
20
1
2.8
20
1.5
7.5
(4.3)
Terminal plate thickness: 0.3
36.5 max.
8
G2R-@-S
5
P2R-05A (1-pole)
7
14.5 max.
1.2
0.3
5
Terminal Arrangement
(Bottom View)
6.7
3.8
35.5 max.
16.7
Panel Cutout
Five, 3 x 1.8-dia. holes
6
13.6 0.1
36.5 max.
1.2
Terminal plate thickness: 0.3
30.5 0.2
7
7
14.5 max.
P2R-08A (2-pole)
0.3
2.6
5
5
35.5 max.
Recommended thickness of
the panel is 1.6 to 2.0 mm
20
2.8
1.5
Eight, 3 x 1.2-dia. holes
7.5
Terminal plate thickness: 0.3
36.5 max.
P2R-057P
Terminal Arrangement
(Bottom View)
Mounting Holes
14 max.
8.7
16.4
Five,
0.7
10.4
1
4 0.1
1.6-dia.
holes
6 0.1
29.6
37 max.
4.5 0.1
15 0.1
4 0.1
5
8.7
7.4
7 0.1
41 max.
14 max.
7.5
Terminal Arrangement
(Bottom View)
Mounting Holes
P2R-087P
16.4
1
Eight,
10.4
7.5
1.3-dia.
holes
29.1
37 max.
5
5
20
7.4
8.9
(8.1)
41 max.
Mounting Height of Relay with Back-connecting Sockets
G2R-@P
G2R-@A
G2R-@7P
G2R Relay
G2R Relay
47.5
44.5
P2R-_P
Socket
38.0
P2R-_A
Socket
9
G2R-@-S
Mounting Tracks
PFP-100N, PFP-50N
PFP-100N2
16
7.3 0.15
4.5
4.5
27
35 0.3
29.2
1.5
24
27 0.15
1
35 0.3
15 (5)
15
25
25
15 25
25
25
15 25
25
25
1
10
10
10
10
1,000
1,000 (500)
It is recommended to use a panel 1.6 to 2.0 mm thick.
End Plate
Spacer
PFP-S
16
12
10
6.2
PFP-M
5
1.8
1
35.5 35.3
50
34.8
44.3
1.8
11.5
1.3
4.8
10
M4 x 8 pan
head screw
16.5
Precautions
Cation
• Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
• Check that the test button is released before turning ON relay cir-
cuits.
• If the test button is pulled out too forcefully, it may bypass the mo-
mentary testing position and go straight into the locked position.
• Use an insulated tool when you operate the test button.
Precautions for P2RF-@-S Connection
• Do not move the screwdriver up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
• Do not insert the screwdriver at an angle. Doing so may break the
side of the socket and result in a short-circuit.
10
相关型号:
G2R-2-SN-DC12(S)
Power/Signal Relay, SPDT, Momentary, 0.043A (Coil), 12VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
G2R-2-SN-DC48(S)
Power/Signal Relay, SPDT, Momentary, 0.011A (Coil), 48VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
G2R-2-SN-DC6(S)
Power/Signal Relay, SPDT, Momentary, 0.087A (Coil), 6VDC (Coil), 530mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON
G2R-2-SN24VDC
Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.022A (Coil), 24VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, Random, AC/DC Output, Socket Mount,
OMRON
G2R-2-SNAC200/(220)
Power/Signal Relay, DPDT, Momentary, 5A (Contact), 125VDC (Contact), AC/DC Output, Panel Mount,
OMRON
G2R-2-SND-100VDC
Power/Signal Relay, DPDT, Momentary, 0.005A (Coil), 100VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
G2R-2-SND-12VDC
Power/Signal Relay, DPDT, Momentary, 0.044A (Coil), 12VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
G2R-2-SND-24VDC
Power/Signal Relay, DPDT, Momentary, 0.022A (Coil), 24VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
G2R-2-SND-48VDC
Power/Signal Relay, DPDT, Momentary, 0.012A (Coil), 48VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
G2R-2-SND-5VDC
Power/Signal Relay, DPDT, Momentary, 0.106A (Coil), 5VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
G2R-2-SND-6VDC
Power/Signal Relay, DPDT, Momentary, 0.088A (Coil), 6VDC (Coil), 530mW (Coil), 4A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON
©2020 ICPDF网 联系我们和版权申明