G2RS-S [OMRON]

General-purpose Relay; 通用继电器
G2RS-S
型号: G2RS-S
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

General-purpose Relay
通用继电器

继电器
文件: 总12页 (文件大小:782K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General-purpose Relay  
G2RS-(S)  
Slim and Space-saving Power Plug-in Relay  
• Lockable test button models now available.  
• Built-in mechanical operation indicator.  
• Provided with nameplate.  
• AC type is equipped with a coil-disconnection self-  
diagnostic function (LED type).  
• High switching power (1-pole: 10 A).  
• Environment-friendly (Cd, Pb free).  
• Wide range of Sockets also available.  
• RoHS Compliant.  
LR  
Model Number Structure  
Model Number Legend  
G2R  
-
-
-
(S)  
1
2
3
4
5
6
7
1. Relay Function  
5. Terminals  
Blank:General-purpose  
S:  
Plug-in  
2. Number of Poles  
6. Classification  
Blank:General-purpose  
1:  
2:  
1 pole  
2 poles  
N:  
D:  
LED indicator  
Diode  
3. Contact Form  
Blank:SPDT  
4. Contact Type  
Blank:Single  
ND: LED indicator and diode  
NI: LED indicator with test button  
NDI: LED indicator and diode with test button  
7. Rated Coil Voltage  
Ordering Information  
List of Models  
Classification  
Enclosure  
rating  
Coil ratings  
AC/DC  
Contact form/Model  
SPDT DPDT  
Plug-in terminal  
General-purpose  
Unsealed  
G2R-1-S  
G2R-2-S  
LED indicator  
G2R-1-SN  
G2R-1-SNI  
G2R-1-SD  
G2R-1-SND  
G2R-1-SNDI  
G2R-2-SN  
G2R-2-SNI  
G2R-2-SD  
G2R-2-SND  
G2R-2-SNDI  
LED indicator with test button  
Diode  
DC  
LED indicator and diode  
LED indicator and diode with test button  
Note: When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.  
New model  
Example: G2R-1-S DC12 (S)  
Rated coil voltage  
General-purpose Relay G2RS-(S)  
245  
Accessories (Order Separately)  
Connecting Sockets  
Applicable Relay model  
Track/surface-mounting Socket  
Back-mounting Socket  
Terminals Model  
Screwless clamp terminal  
Screw terminal  
(See note.)  
1 pole  
P2RF-05-S  
+
P2CM-S  
PCB terminals  
P2R-05P, P2R-057P  
P2R-05A  
P2RF-05-E  
P2RF-05  
G2R-1-S(N)(D)(ND)(NI)(NDI)  
Solder terminals  
2 poles  
G2R-2-S(N)(D)(ND)(NI)(NDI)  
P2RF-08-S  
+
P2CM-S  
PCB terminals  
P2R-08P, P2R-087P  
P2R-08A  
P2RF-08-E  
P2RF-08  
Solder terminals  
Note: 1. Use of P2CM Clips are optional. However, use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.  
2. “-E” models are of finger-safe product construction. Round terminals cannot be used. Use Y-shaped terminals.  
Accessories for Screwless Clamp Terminal Socket (Option)  
Name  
Model  
Clip & Release Lever  
Nameplate  
P2CM-S  
R99-11 Nameplate for MY  
Socket Bridge  
P2RM-SR (for AC), P2RM-SB (for DC)  
Mounting Tracks  
Applicable Socket  
Description  
Model  
Mounting track and accessories  
Mounting track  
50 cm (l) x 7.3 mm (t) PFP-50N  
1 m (l) x 7.3 mm (t)  
1 m (l) x 16 mm (t)  
PFP-100N  
PFP-100N2  
End plate  
Spacer  
PFP-M  
PFP-S  
P2R-P  
Mounting plate*  
Back-connecting Sockets  
*Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.  
Specifications  
Coil Ratings  
Rated voltage  
Rated current*  
Coil  
resistance*  
Coil inductance (H)  
(ref. value)  
Must  
operate  
voltage  
Must  
release  
voltage  
Max.  
voltage  
Power  
consumption  
(approx.)  
50 Hz  
60 Hz  
Armature Armature  
% of rated voltage  
OFF  
ON  
AC 24 V  
110 V  
43.5 mA  
9.5 mA  
8.6 mA  
4.4 mA  
3.7 mA  
37.4 mA  
8.2 mA  
7.5 mA  
3.8 mA  
3.2 mA  
253 Ω  
0.81  
1.55  
80% max. 30% min. 110%  
0.9 VA at 60 Hz  
5,566 Ω  
7,286 Ω  
27,172 Ω  
30,360 Ω  
13.33  
16.13  
72.68  
90.58  
26.83  
120 V  
32.46  
230 V  
143.90  
182.34  
240 V  
Rated voltage  
Rated current*  
Coil  
resistance*  
Coil inductance (H)  
(ref. value)  
Must  
operate  
voltage  
Must  
release  
voltage  
Max.  
voltage  
Power  
consumption  
(approx.)  
Armature Armature  
% of rated voltage  
OFF  
0.25  
ON  
DC 6 V  
12 V  
87.0 mA  
69 Ω  
0.48  
2.35  
8.25  
70% max. 15% min. 110%  
0.53 W  
43.2 mA  
21.6 mA  
11.4 mA  
278 Ω  
0.98  
3.60  
15.2  
24 V  
1,113 Ω  
4,220 Ω  
48 V  
29.82  
* The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%.  
246  
General-purpose Relay G2RS-(S)  
Contact Ratings  
Number of poles  
1 pole  
Inductive load  
2 poles  
Inductive load  
Load  
Resistive load  
(cosφ = 1)  
Resistive load  
(cosφ = 1)  
(cosφ = 0.4; L/R = 7 ms)  
(cosφ = 0.4; L/R = 7 ms)  
Rated load  
10 A at 250 VAC;  
10 A at 30 VDC  
7.5 A at 250 VAC;  
5 A at 30 VDC  
5 A at 250 VAC;  
5 A at 30 VDC  
2 A at 250 VAC; 3 A at  
30 VDC  
Rated carry current  
10 A  
5 A  
Max. switching voltage  
Max. switching current  
Max. switching capacity  
440 VAC, 125 VDC  
10 A  
380 VAC, 125 VDC  
5 A  
2,500 VA,  
300 W  
1,875 VA,  
150 W  
1,250 VA,  
150 W  
500 VA,  
90 W  
Minimum permissible load  
100 mA at 5 VDC  
10 mA at 5 VDC  
Note: P level: λ60 = 0.1 x 10-6/operation  
Characteristics  
Item  
1 pole  
2 poles  
Contact resistance  
Operate (set) time  
Release (reset) time  
100 mΩ max.  
15 ms max.  
AC: 10 ms max.; DC: 5 ms max.  
(w/built-in diode: 20 ms max.)  
AC: 15 ms max.; DC: 10 ms max.  
(w/built-in diode: 20 ms max.)  
Max. operating  
frequency  
Mechanical:  
Electrical:  
18,000 operations/hr  
1,800 operations/hr (under rated load)  
Insulation resistance 1,000 MΩ min. (at 500 VDC)  
Dielectric strength  
5,000 VAC, 50/60 Hz for 1 min between coil and  
contacts*;  
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;  
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity  
1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity  
same polarity  
Vibration resistance  
Shock resistance  
Destruction:  
Malfunction:  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Destruction:  
Malfunction:  
1,000 m/s2  
200 m/s2 when energized; 100 m/s2 when not energized  
Service life  
Mechanical:  
AC coil: 10,000,000 operations min.;  
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)  
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)  
Electrical:  
Ambient temperature Operating:  
–40°C to 70°C (with no icing or condensation)  
Ambient humidity  
Weight  
Operating:  
5% to 85%  
Approx. 21 g  
Note: Values in the above table are the initial values.  
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is used.  
Approved Standards  
UL Recognized (File No. E41643) - - Ambient Temp. = 40°C  
IEC/VDE (EN61810)  
Model Contact Coil ratings  
form  
Contact ratings  
Cycles  
Contact  
form  
Coil ratings  
Contact ratings  
Cycles  
10 A, 30 VDC (resistive)  
6, 12, 24, 48 VDC  
24, 110, 120, 230,  
240 VAC  
5 A, 440 VAC (cosφ = 1.0)  
10 A, 250 VAC (cosφ = 1.0)  
10 A, 30 VDC (0 ms)  
G2R-1-S SPDT  
10 A, 250 VAC (general use) 6 x 103  
TV-3 (NO contact only)  
1 pole  
2 poles  
LR  
100 x 103  
100 x 103  
5 to 110 VDC  
5 to 240 VAC  
5 A, 30 VDC (resistive)  
5 A, 250 VAC (general use)  
TV-3 (NO contact only)  
6, 12, 24, 48 VDC  
24, 110, 120, 230,  
240 VAC  
5 A, 250 VAC (cosφ =1.0)  
5 A, 30 VDC (0 ms)  
G2R-2-S DPDT  
6 x 103  
CSA Certified (File No. LR31928)  
Model Contact Coil ratings  
form  
Contact ratings  
Cycles  
Number Coil ratings  
of poles  
Contact ratings  
Cycles  
10 A, 30 VDC (resistive)  
10 A, 250 VAC (general use)  
G2R-1-S SPDT  
10 A, 250 VAC (general use) 6 x 103  
TV-3 (NO contact only)  
5 to 110 VDC 7.5 A, 250 VAC (PF0.4)  
5 to 240 VDC 10 A, 30 VDC (resistive)  
5A, 30VDC (L/R=7ms)  
1 pole  
100 x 103  
5 to 110 VDC  
5 to 240 VAC  
5 A, 30 VDC (resistive)  
5 A, 250 VAC (general use)  
TV-3 (NO contact only)  
G2R-2-S DPDT  
6 x 103  
5 A, 250 VAC (general use)  
5 to 110 VDC 2 A, 250 VAC (PF0.4)  
5 to 240 VDC 5 A, 30 VDC (resistive)  
3A, 30VDC (L/R=7ms)  
2 poles  
100 x 103  
General-purpose Relay G2RS-(S)  
247  
Engineering Data  
Maximum Switching Capacity  
Plug-in Relays  
G2R-1-S  
G2R-2-S  
100  
100  
AC inductive load  
(cosφ = 0.4)  
AC resistive  
load  
AC inductive load  
(cosφ = 0.4)  
AC resistive  
load  
10  
10  
1
DC resistive  
load  
DC resistive  
load  
DC inductive load  
(L/R = 7 ms)  
1
DC inductive load  
(L/R = 7 ms)  
0.1  
0.1  
1
10  
100  
1000  
1
10  
100  
1000  
Switching voltage (V)  
Switching voltage (V)  
Electrical Service Life  
Plug-in Relays  
G2R-1-S  
G2R-2-S  
10,000  
5,000  
5,000  
250-VAC/30-VDC  
1,000  
500  
resistive load  
1,000  
500  
250-VAC inductive load  
(cosφ = 0.4)  
30-VDC inductive load (L/R = 7ms)  
250-VAC/30-VDC  
resistive load  
100  
50  
100  
50  
30-VDC inductive load (L/R = 7ms)  
250-VAC  
inductive load  
(cosφ = 0.4)  
Switching current (A)  
Switching current (A)  
Ambient Temperature vs. Maximum Coil Voltage  
DC coil  
AC coil  
Note: The maximum voltage refers to the maximum  
value in a varying range of operating power  
voltage, not a continuous voltage.  
Ambient temperature (°C)  
248  
General-purpose Relay G2RS-(S)  
Dimensions  
Unit: mm (inch)  
Relays with Plug-in Terminals  
SPDT Relays  
Terminal Arrangement/Internal Connections  
(Bottom View)  
G2R-1-S, G2R-1-SN, G2R-1-SNI  
G2R-1-SD, G2R-1-SND, G2R-1-SNDI  
G2R-1-SD (DC)  
G2R-1-S  
1
5
1
5
13 max.  
(0.51)  
29 (1.14) max.  
2
4
3
2
4
3
35.5 max.  
(1.40)  
G2R-1-SN, G2R-1-SNI (DC)  
G2R-1-SN, G2R-1-SNI (AC)  
20  
(0.79)  
1
1
D
C24V  
5 (0.20)  
1(0.04)  
4.75  
(0.19)  
0.5  
(0.02)  
2
4
3
2
4
3
5
5
7.5 (0.29)  
G2R-1-SND, G2R-1-SNDI (DC)  
5.2  
5.2  
(0.20)  
(0.20)  
17.5  
1
(0.69)  
2
4
3
5
DPDT Relays  
G2R-2-S, G2R-2-SN, G2R-2-SNI  
G2R-2-SD, G2R-2-SND, G2R-2-SNDI  
Terminal Arrangement/Internal Connections  
(Bottom View)  
G2R-2-S  
G2R-2-SD (DC)  
1
2
7
3
6
4
5
1
2
7
3
4
29 max.  
(1.14)  
13 max.  
(0.51)  
8
8
6
5
35.5 max.  
(1.40)  
G2R-2-SN, G2R-2-SNI (AC)  
G2R-2-SN, G2R-2-SNI (DC)  
20  
(0.79)  
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
6.2  
(0.29)  
2.5  
(0.10)  
0.5  
(0.02)  
2.4  
(0.09)  
7.4  
8.9  
(0.29)  
(0.35)  
G2R-2-SND, G2R-2-SNDI (DC)  
5 (0.02)  
5 (0.02)  
1
8
2
7
3
6
4
5
19.4  
(0.76)  
General-purpose Relay G2RS-(S)  
249  
Track/Surface Mounting Sockets  
P2RF-05-S  
Terminal Arrangement  
(Top View)  
38.2 max. (1.50)  
36.5 max. (1.44)  
11  
14  
12  
32.6 (1.28)  
27.6 (1.09)  
22.6  
(0.89)  
24.5  
(0.96)  
35.4  
(1.39)  
92.0 max.  
(3.62)  
A1 A2  
Option (with ejector and  
Standard model  
label attached)  
28.5 (1.12)  
5.3 typical  
(0.21)  
18.0 max.  
(0.71)  
32.6  
(1.28)  
Terminal Arrangement  
(Top View)  
38.2 max. (1.50)  
P2RF-08-S  
36.5 max.(1.44)  
21 11  
24 14  
22 12  
32.6 (1.28)  
27.6 (1.09)  
22.6  
(0.89)  
3.4 (0.13) typical  
24.5  
(0.96)  
92.0 max.  
(3.62)  
35.4  
(1.39)  
A1 A2  
Option (with ejector  
and label attached)  
Standard model  
28.6 (1.12)  
32.6 (1.28)  
5.3 typical  
(0.21)  
18.0 max.  
(0.71)  
Accessories for P2RF-@-S  
Socket Bridge  
Clip and Release Lever  
16.8  
(0.66)  
40.35  
(1.59)  
Note: The color of insulating coating indicates power type.  
36  
(1.42)  
Model  
Power  
Color  
P2RM-SR  
P2RM-SB  
AC  
DC  
Red  
Blue  
250  
General-purpose Relay G2RS-(S)  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
P2RF-05-E  
2 (0.08)  
Five, M3.5×7  
48 max.  
(1.89)  
3.2 (0.13)  
dia. hole  
(11)  
4
39.5  
(1.55)  
35.5  
(1.40)  
2
(14)  
3
(12)  
39.5 0.1  
(1.55 0.004)  
85.5 max.  
(3.37)  
3.5 (0.14)  
dia. hole  
5
M3 or 3.5  
(0.14) dia.  
(A1)  
(A2)  
1
5
11.5  
(0.20)  
(0.45)  
16.0 max.  
(0.63)  
61 max.  
(2.40)  
Note: Pin numbers in parentheses apply to DIN standard.  
P2RF-08-E  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
1.5  
(0.06)  
2 (0.08)  
3 (0.12)  
48.0 max.  
(1.89)  
Eight, M3×8  
2 (0.08)  
(11)  
(12)  
(14)  
(21)  
(22)  
(24)  
6
3
2
4
3.2 (0.13)  
dia. hole  
7
5
39.5  
(1.55)  
35.5  
(1.40)  
85.5 max  
(3.37)  
39.5 0.1  
(1.55 0.004)  
8
3.5 (0.14)  
dia. hole  
(A1)  
1
M3 or 3.5 (0.14)  
dia. hole  
(A2)  
11.5 (0.45)  
5 (0.20)  
61.0 max.  
(2.40)  
16.0 (0.63) max.  
2 (0.08)  
7(0.28)  
Five, M3.5 x 8  
P2RF-05  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
4 (0.16)  
dia. holes  
4.2 (0.16)  
dia. hole  
71.5 max.  
35.5  
(2.81)  
(1.40)  
30 0.05  
(1.18 0.002)  
4
19.5 (0.77)  
30 max.(1.18)  
M3 or 3.2 (0.13)  
dia. hole  
19.5 max.  
(0.77)  
(0.16)  
54 max.  
(2.12)  
P2RF-08  
2 (0.08)  
7 (0.28)  
Eight, M3.5 x 8  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
4.2 (0.16) dia. hole  
4 (0.16)  
dia. holes  
71.5 max.  
(2.89)  
35.5  
(1.40)  
30 0.05  
(1.18 0.002)  
19.5 (0.77)  
30 max.(1.18)  
4 (0.16)  
19.5 max.  
(0.77)  
M3 or 3.2 (0.13)  
dia. hole  
54 max.  
(2.12)  
General-purpose Relay G2RS-(S)  
251  
Mounting Height of Relay with Track/Surface Mounting Sockets  
P2RF-@-E  
P2RF-@  
62.0  
(2.44)  
66.5  
(2.62)  
67.0  
(2.64)  
70.5  
(2.77)  
P2RF-@-S  
72.0  
(2.83)  
65.0  
(2.56)  
28.6  
(1.12)  
5.30 (0.21) typical  
Back-connecting Sockets  
Terminal Arrangement  
(Bottom View)  
Mounting Holes  
14.5 max.  
(0.57)  
P2R-05P (1-pole)  
Tolerance: 0.1  
4 (0.16)  
1(0.04)  
7 (0.27)  
4 (0.14)  
Five, 1.6 (0.06)  
dia. holes  
6 (0.24)  
4.5 (0.18)  
15  
35.5 max.  
(1.40)  
6 (0.24)  
(0.59)  
4.5 (0.18)  
15 (0.59)  
1.2 (0.05)  
4 (0.16)  
3.5  
(0.14)  
4 (0.16)  
1.5 (0.06)  
5 (0.20) typical  
7 (0.27)  
4 (0.16)  
7 (2.27)  
36.5 max.  
(1.44)  
P2R-08P (2-pole)  
14.5 max.  
(0.57)  
Terminal Arrangement  
(Bottom View)  
Mounting Holes  
4 (0.16)  
0.3  
7 (0.27)  
7.5  
(0.29)  
Eight, 1.3 (0.05)  
dia. holes  
(0.01)  
5 (0.20)  
5 (0.20)  
35.5 max.  
(1.40)  
5 (0.20)  
20  
(0.79)  
1 (0.04)  
5 (0.20)  
20  
(0.79)  
2.8 (0.11)  
1.5 (0.06)  
7.5 (0.29)  
4.3 (0.17) typical  
Terminal plate thickness: 0.3 (0.01)  
36.5 max. (1.44)  
252  
General-purpose Relay G2RS-(S)  
5 (0.20)  
0.3  
(0.01)  
14.5 max.  
(0.57)  
7 (0.28)  
1.2 (0.05)  
P2R-05A (1-pole)  
Terminal Arrangement  
(Bottom View)  
6.7 (0.26)  
3.8 (0.15)  
35.5 max.  
(1.40)  
16.7  
(0.66)  
5 (0.20)  
Panel Cutout  
Five, 3 x 1.8-dia. holes  
(0.12 x 0.07)  
13.6 0.1  
(0.54 0.004)  
6 (0.24)  
36.5 max.  
(1.44)  
Terminal plate thickness: 0.3  
7 (0.28)  
30.5 0.2  
(1.20 0.008)  
14.5 max.  
(0.57)  
7 (0.28)  
1.2 (0.05)  
P2R-08A (2-pole)  
0.3  
(0.01)  
5 (0.20)  
5 (0.20)  
35.5 max.  
(1.40)  
20  
Recommended thickness of  
the panel is 1.6 to 2.0 mm  
(0.79)  
2.6 (0.10)  
2.8(0.11)  
1.5 (0.06)  
Eight, 3 x 1.2  
(0.12 x 0.05)dia. holes  
7.5  
(0.30)  
Terminal plate thickness: 0.3  
36.5 max.  
(1.44)  
P2R-057P 14 max. (0.55)  
Terminal Arrangement  
(Bottom View)  
Mounting Holes  
4 0.1  
16.4 (0.65)  
10.4  
0.7 (0.03)  
1(0.04)  
8.7  
(0.16 0.004)  
(0.41)  
Five, 1.6 (0.06)  
dia. holes  
6 0.1(0.24 0.004)  
(0.34)  
29.6  
(1.17)  
37 max.  
(1.46)  
4.5 0.1  
(0.18 0.004)  
15 0.1(0.59 0.004)  
7.4 (0.29)  
4 0.1 (0.16 0.004)  
5 (0.20)  
8.7  
(0.34)  
7 0.1(0.27 0.004)  
41 max.  
(1.61)  
14 max.  
(0.55)  
Terminal Arrangement  
(Bottom View)  
Mounting Holes  
16.4(0.65)  
1 (0.04)  
P2R-087P  
10.4  
7.5  
(0.30)  
7.5 (0.30)  
Eight, 1.3 (0.05)  
(0.41)  
dia. holes  
37 max.  
29.1  
(1.15)  
(1.46)  
5 (0.20)  
5 (0.20)  
20  
(0.79)  
7.4 (0.29)  
8.9 (0.35)  
8.1(0.32) typical  
41 max.  
(1.61)  
General-purpose Relay G2RS-(S)  
253  
Mounting Height of Relay with Back-connecting Sockets  
G2R-@P  
G2R-@A  
G2R-@7P  
G2R Relay  
G2R Relay  
47.5  
(1.87)  
38.0  
(1.50)  
44.5  
(1.75)  
P2R-_A  
Socket  
P2R-_P  
Socket  
Mounting Tracks  
PFP-100N, PFP-50N  
PFP-100N2  
16 (0.63)  
7.3 0.15  
(0.29 0.006)  
4.5  
4.5 (0.18)  
(0.18)  
24  
(0.94)  
27  
(1.06)  
29.2  
(1.15)  
35 0.3  
(1.38 0.01)  
27 0.15  
1
35 0.3  
15  
25  
25  
10 (0.39)  
25  
25  
10 (0.39)  
25  
25  
15 (0.59)  
25 (0.98)  
1 (0.04)  
1.5 (0.06)  
15 (0.59)  
25 (0.98)  
1,000 (39.37)  
or 500 (19.68)  
15(0.59)  
or 5 (0.20)  
10  
10  
1,000  
(39.37)  
It is recommended to use a panel 1.6 to 2.0 mm thick.  
End Plate  
Spacer  
16 (0.63)  
10 (0.39)  
6.2 (0.24)  
5 (0.20)  
12 (0.47)  
PFP-M  
PFP-S  
1.8 (0.07)  
1 (0.04)  
35.5  
(1.40)  
35.3  
(1.39)  
50  
(1.97)  
34.8  
(1.37)  
1.8  
(0.07)  
44.3  
(1.74)  
11.5  
(0.45)  
1.3 (0.05)  
4.8 (0.19)  
10 (0.39)  
M4 x 8 pan  
head screw  
16.5 (0.65)  
Precautions  
Precautions for P2RF-@-S Connection  
Do not move the screwdriver up, down, or from side to side while it  
is inserted in the hole. Doing so may cause damage to internal  
components (e.g., deformation of the clamp spring or cracks in the  
housing) or cause deterioration of insulation.  
!CAUTION  
Do not use the test button for any purpose other than testing. Be  
sure not to touch the test button accidentally as this will turn the  
contacts ON. Before using the test button, confirm that circuits, the  
load, and any other connected item will operate safely.  
Do not insert the screwdriver at an angle. Doing so may break the  
side of the socket and result in a short-circuit.  
!CAUTION  
Check that the test button is released before turning ON relay cir-  
cuits.  
!CAUTION  
If the test button is pulled out too forcefully, it may bypass the mo-  
mentary testing position and go straight into the locked position.  
!CAUTION  
Use an insulated tool when you operate the test button.  
254  
General-purpose Relay G2RS-(S)  
(b) Use in consumer Products or any use in significant quantities.  
(c) Energy control systems, combustion systems, railroad systems, aviation systems,  
medical equipment, amusement machines, vehicles, safety equipment, and  
installations subject to separate industry or government regulations.  
(d) Systems, machines, and equipment that could present a risk to life or property.  
3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING  
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM  
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE  
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE  
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED  
VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY  
SELLER.  
5. Programmable Products: Seller shall not be responsible for the Buyer's programming of  
a programmable Product.  
Omron Electronic Components, LLC  
Terms and Conditions of Sales  
I. GENERAL  
1. Definitions: The words used herein are defined as follows.  
(a) Terms:  
(b) Seller:  
(c) Buyer:  
These terms and conditions  
Omron Electronic Components LLC and its subsidiaries  
The buyer of Products, including any end user in section III through VI  
(d) Products: Products and/or services of Seller  
(e) Including: Including without limitation  
2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments,  
invoices, purchase orders and other documents, whether electronic or in writing, relating  
to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's  
purchase order or other documents which are inconsistent with, or in addition to, these  
Terms.  
3. Distributor: Any distributor shall inform its customer of the contents after and including  
section III of these Terms.  
IV. WARRANTY AND LIMITATION  
1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in  
materials and workmanship for a period of twelve months from the date of sale by Seller  
(or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY  
OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES,  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE OF THE PRODUCTS.  
2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form  
originally shipped with Buyer responsible for labor charges for removal or replacement  
thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an  
amount equal to the purchase price of the Product; provided that there shall be no  
liability for Seller or its affiliates unless Seller's analysis confirms that the Products were  
correctly handled, stored, installed and maintained and not subject to contamination,  
abuse, misuse or inappropriate modification. Return of any Products by Buyer must be  
approved in writing by Seller before shipment.  
3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR  
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF  
PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED  
WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,  
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL  
LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF  
THE PRODUCT ON WHICH LIABILITY IS ASSERTED.  
4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its  
employees from and against all liabilities, losses, claims, costs and expenses (including  
attorney's fees and expenses) related to any claim, investigation, litigation or proceeding  
(whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or  
omissions under these Terms or in any way with respect to the Products.  
II. SALES  
1. Prices; Payment: All prices stated are current, subject to change without notice by Seller.  
Buyer agrees to pay the price in effect at the time the purchase order is accepted by  
Seller. Payments for Products received are due net 30 days unless otherwise stated in  
the invoice. Buyer shall have no right to set off any amounts against the amount owing in  
respect of this invoice.  
2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to  
Buyer after deducting transportation charges, taxes and duties, and will be allowed only  
if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past  
due amounts owing to Seller.  
3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum  
legal rate, whichever is less, on any balance not paid within the stated terms.  
4. Orders: Seller will accept no order less than 200 U.S. dollars net billing.  
5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer  
shall make remittance to Seller at the then current exchange rate most favorable to  
Seller; provided that if remittance is not made when due, Buyer will convert the amount  
to U.S. dollars at the then current exchange rate most favorable to Seller available  
during the period between the due date and the date remittance is actually made.  
6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining  
any government approvals regarding the importation or sale of the Products.  
7. Taxes: All taxes, duties and other governmental charges (other than general real  
property and income taxes), including any interest or penalties thereon, imposed directly  
or indirectly on Seller or required to be collected directly or indirectly by Seller for the  
manufacture, production, sale, delivery, importation, consumption or use of the Products  
sold hereunder (including customs duties and sales, excise, use, turnover and license  
taxes) shall be charged to and remitted by Buyer to Seller.  
V. INFORMATION; ETC.  
1. Intellectual Property: The intellectual property embodied in the Products is the exclusive  
property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way  
without the written permission of Seller. Buyer (at its own expense) shall indemnify and  
hold harmless Seller and defend or settle any action brought against Seller to the extent  
that it is based on a claim that any Product made to Buyer specifications infringed  
intellectual property rights of another party.  
2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or  
tooling, all engineering and tooling shall remain the exclusive property of Seller. All  
information and materials supplied by Seller to Buyer relating to the Products are  
confidential and proprietary, and Buyer shall limit distribution thereof to its trusted  
employees and strictly prevent disclosure to any third party.  
3. Performance Data: Performance data is provided as a guide in determining suitability  
and does not constitute a warranty. It may represent the result of Seller's test conditions,  
and the users must correlate it to actual application requirements.  
4. Change In Specifications: Product specifications and descriptions may be changed at  
any time based on improvements or other reasons. It is Seller’s practice to change part  
numbers when published ratings or features are changed, or when significant  
engineering changes are made. However, some specifications of the Product may be  
changed without any notice.  
8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller,  
Seller reserves the right to stop shipments or require satisfactory security or payment in  
advance. If Buyer fails to make payment or otherwise comply with these Terms or any  
related agreement, Seller may (without liability and in addition to other remedies) cancel  
any unshipped portion of Products sold hereunder and stop any Products in transit until  
Buyer pays all amounts, including amounts payable hereunder, whether or not then due,  
which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid  
accounts.  
9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer  
indemnifies Seller fully against all costs or expenses arising in connection therewith.  
10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from  
causes beyond its control, including earthquakes, fires, floods, strikes or other labor  
disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots,  
delay in or lack of transportation or the requirements of any government authority.  
11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller:  
(a) All sales and shipments of Products shall be FOB shipping point (unless otherwise  
stated in writing by Seller), at which point title to and all risk of loss of the Products  
shall pass from Seller to Buyer, provided that Seller shall retain a security interest in  
the Products until the full purchase price is paid by Buyer;  
5. Errors And Omissions: The information on Seller’s website or in other documentation  
has been carefully checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses  
regarding (a) export of the Products or information provided by Seller; (b) sale of  
Products to forbidden or other proscribed persons or organizations; (c) disclosure to non-  
citizens of regulated technology or information.  
(b) Delivery and shipping dates are estimates only; and  
(c) Seller will package Products as it deems proper for protection against normal  
handling and extra charges apply to special conditions.  
12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products  
occurring before delivery to the carrier or any claim related to pricing or other charges  
must be presented in detail in writing to Seller within 30 days of receipt of shipment.  
III. PRECAUTIONS  
VI. MISCELLANEOUS  
1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY  
OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE  
APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING  
APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE  
BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC  
COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E)  
SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT.  
Buyer acknowledges that it alone has determined that the Products will meet their  
requirements of the intended use in all cases. Buyer must know and observe all  
prohibitions of use applicable to the Product/s.  
1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing  
between Buyer and Seller shall operate as a waiver of rights by Seller.  
2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.  
3. Law: These Terms are governed by Illinois law (without regard to conflict of laws).  
Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any  
dispute hereunder.  
4. Amendment: These Terms constitute the entire agreement between Buyer and Seller  
relating to the Products, and no provision may be changed or waived unless in writing  
signed by the parties.  
5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall  
not invalidate any other provision.  
2. Use with Attention: The followings are some examples of applications for which  
particular attention must be given. This is not intended to be an exhaustive list of all  
possible use of any Product, nor to imply that any use listed may be suitable for any  
Product:  
(a) Outdoor use, use involving potential chemical contamination or electrical  
interference.  
General-purpose Relay G2RS-(S)  
Certain Precautions on Specifications and Use  
1. Suitability for Use. Seller shall not be responsible for conformity with any stan- 2. Programmable Products. Seller shall not be responsible for the user's pro-  
dards, codes or regulations which apply to the combination of the Product in  
gramming of a programmable product, or any consequence thereof.  
Buyer's application or use of the Product. At Buyer's request, Seller will pro- 3. Performance Data. Performance data given in this publication is provided as  
vide applicable third party certification documents identifying ratings and limi-  
tations of use which apply to the Product. This information by itself is not  
sufficient for a complete determination of the suitability of the Product in com-  
bination with the end product, machine, system, or other application or use.  
a guide for the user in determining suitability and does not constitute a war-  
ranty. It may represent the result of Seller's test conditions, and the users must  
correlate it to actual application requirements. Actual performance is subject to  
Seller's Warranty and Limitations of Liability.  
Buyer shall be solely responsible for determining appropriateness of the par- 4. Change in Specifications. Product specifications and accessories may be  
ticular Product with respect to Buyer's application, product or system. Buyer  
shall take application responsibility in all cases but the following is a non-  
exhaustive list of applications for which particular attention must be given:  
(i) Outdoor use, uses involving potential chemical contamination or electrical  
interference, or conditions or uses not described in this document.  
(ii) Energy control systems, combustion systems, railroad systems, aviation  
systems, medical equipment, amusement machines, vehicles, safety  
equipment, and installations subject to separate industry or government  
regulations.  
(iii) Use in consumer products or any use in significant quantities.  
(iv) Systems, machines and equipment that could present a risk to life or  
property. Please know and observe all prohibitions of use applicable to this  
product.  
changed at any time based on improvements and other reasons. It is our prac-  
tice to change part numbers when published ratings or features are changed,  
or when significant construction changes are made. However, some specifica-  
tions of the Product may be changed without any notice. When in doubt, spe-  
cial part numbers may be assigned to fix or establish key specifications for  
your application. Please consult with your Seller representative at any time to  
confirm actual specifications of purchased Product.  
5. Errors and Omissions. The information in this publication has been carefully  
checked and is believed to be accurate; however, no responsibility is assumed  
for clerical, typographical or proofreading errors, or omissions.  
6. RoHS Compliance. Where indicated, our products currently comply, to the  
best of our knowledge as of the date of this publication, with the requirements  
of the European Union's Directive on the Restriction of certain Hazardous  
Substances ("RoHS"), although the requirements of RoHS do not take effect  
until July 2006. These requirements may be subject to change. Please consult  
our website for current information.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS  
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM  
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT  
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE  
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website  
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
06/09  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X301-E-1a  
General-purpose Relay G2RS-(S)  

相关型号:

G2RV

Slim Relay
OMRON

G2RV-1-S-AP-GDC11

Global standard size, low profile slim (6.2 mm width) I/O relays
OMRON

G2RV-1-S-AP-GDC21

Global standard size, low profile slim (6.2 mm width) I/O relays
OMRON

G2RV-1-S-AP-GDC48

Global standard size, low profile slim (6.2 mm width) I/O relays
OMRON

G2RV-1-S-GDC11

Global standard size, low profile slim (6.2 mm width) I/O relays
OMRON

G2RV-1-S-GDC21

Global standard size, low profile slim (6.2 mm width) I/O relays
OMRON

G2RV-1-S-GDC48

Global standard size, low profile slim (6.2 mm width) I/O relays
OMRON

G2RV-1-SDC11

Power/Signal Relay
OMRON

G2RV-1-SDC21

Power/Signal Relay
OMRON

G2RV-1-SI-GDC21

Global standard size, low profile slim (6.2 mm width) I/O relays
OMRON

G2RV-1-SI21VDC

Power/Signal Relay, SPDT, Momentary, 21VDC (Coil), 6A (Contact), 125VDC (Contact), AC/DC Output, Socket Mount
OMRON

G2RV-SL500-AC230

Power/Signal Relay, SPDT, Momentary, 1700mW (Coil), 6A (Contact), 125VDC (Contact), AC Input, AC/DC Output, DIN-Rail Mount
OMRON