G3PB-245B-3N-VD [OMRON]
Trigger Output SSR, 2500V Isolation;型号: | G3PB-245B-3N-VD |
厂家: | OMRON ELECTRONICS LLC |
描述: | Trigger Output SSR, 2500V Isolation |
文件: | 总10页 (文件大小:1376K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Solid State Contactors (New Heat Sink Construction)
G3PB-2N/-3N
CSM_G3PB-2N_-3N_DS_E_2_1
Space and working time saved with new heat
sink construction. Series now includes
480-VAC models to allow use in a greater
range of applications.
• A comprehensive lineup that now includes 480-VAC models.
• Slim design with 3-phase output and built-in heat sinks.
• New heat sink construction with smaller mounting section.
• DIN track mounting supported as standard. (Screw mounting is
also possible.)
• Certified by UL, CSA, and VDE.
Refer to Safety Precautions for All Solid State
Relays.
Model Number Structure
■ Model Number Legend
G3PB-@@@-@@-@
2 3 4 5 6
7
1
1. Basic Model Name
G3PB: Solid State Relay
2. Rated Load Power Supply Voltage
2:
5:
200 VAC
480 VAC
3. Rated Load Current
15:
25:
35:
45:
15 A
25 A
35 A
45 A
4. Terminal Type
B:
Screw terminals
5. Single-phase/3-phase and Number of Elements for 3-phase
2:
3:
3-phase, 2-element models
3-phase, 3-element models
6. 3-phase Type
N:
H:
DIN track mounting and built-in heat sink
No heat sink (“hockey puck” type)
7. Certification
VD: Certified by UL, CSA, and VDE
1
G3PB-2N/-3N
Ordering Information
■ Solid State Contactors
Models with Built-in Heat Sinks
Applicable
phase
Main circuit voltage
Zero cross
function
Applicable load current
(with Class-1 AC resistive load)
Number of
poles
Model
3
100 to 240 VAC
Yes
15 A
3
G3PB-215B-3N-VD DC12-24
G3PB-215B-2N-VD DC12-24
G3PB-225B-3N-VD DC12-24
G3PB-225B-2N-VD DC12-24
G3PB-235B-3N-VD DC12-24
G3PB-235B-2N-VD DC12-24
G3PB-245B-3N-VD DC12-24
G3PB-245B-2N-VD DC12-24
G3PB-515B-3N-VD DC12-24
G3PB-515B-2N-VD DC12-24
G3PB-525B-3N-VD DC12-24
G3PB-525B-2N-VD DC12-24
G3PB-535B-3N-VD DC12-24
G3PB-535B-2N-VD DC12-24
G3PB-545B-3N-VD DC12-24
G3PB-545B-2N-VD DC12-24
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
25 A
35 A
45 A
15 A
25 A
35 A
45 A
200 to 480 VAC
Note: The applicable load current depends on the ambient temperature. When ordering, specify the rated input voltage.
Models with Externally Attached Heat Sinks
Applicable
phase
Main circuit voltage
Zero cross
function
Applicable load current
(See note.)
Number of
poles
Model
3
100 to 240 VAC
Yes
15 A
25 A
35 A
45 A
15 A
25 A
35 A
45 A
3
G3PB-215B-3H-VD DC12-24
G3PB-215B-2H-VD DC12-24
G3PB-225B-3H-VD DC12-24
G3PB-225B-2H-VD DC12-24
G3PB-235B-3H-VD DC12-24
G3PB-235B-2H-VD DC12-24
G3PB-245B-3H-VD DC12-24
G3PB-245B-2H-VD DC12-24
G3PB-515B-3H-VD DC12-24
G3PB-515B-2H-VD DC12-24
G3PB-525B-3H-VD DC12-24
G3PB-525B-2H-VD DC12-24
G3PB-535B-3H-VD DC12-24
G3PB-535B-2H-VD DC12-24
G3PB-545B-3H-VD DC12-24
G3PB-545B-2H-VD DC12-24
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
200 to 480 VAC
Note: The applicable load current depends on the heat sink that is connected and the ambient temperature.
For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5.
2
G3PB-2N/-3N
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Operating Circuit (Common)
Item
Common
Rated voltage
Operating voltage range
12 to 24 VDC
9.6 to 30 VDC
Rated input current (Impedance) 10 mA max. (at 24 VDC)
Must operate voltage
Must release voltage
Insulation method
Operation indicator
9.6 VDC max.
1 VDC min.
Phototriac coupler
Yellow LED
Main Circuit of Models with Built-in Heat Sinks
G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB-
215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B-
3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD
Model
Item
Rated load voltage 100 to 240 VAC
Load voltage range 75 to 264 VAC
200 to 480 VAC
180 to 528 VAC
Applicable load
current
(See note 1.)
15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C)
Minimum load cur- 0.2 A
rent
0.5 A
Inrush current re- 150 A
220 A
440 A
220 A
(60 Hz, 1 cycle)
440 A
(60 Hz, 1 cycle)
sistance
(60 Hz, 1 cy- (60 Hz, 1 cy- (60 Hz, 1 cycle)
(peak value)
cle)
cle)
Permissible I2t
(half 60-Hz wave)
121 A2s
260 A2s
1260 A2s
260 A2s
1260 A2s
Applicable load
(resistive load,
AC1) (See note 2.)
5.1 kW max. 8.6 kW max. 12.1 kW max. 15.5 kW max. 12.5 kW max. 20.7 kW max. 29.0 kW max. 37.4 kW max.
(at 200 VAC) (at 200 VAC) (at 200 VAC) (at 200 VAC) (at 480 VAC) (at 480 VAC) (at 480 VAC) (at 480 VAC)
Note: 1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in
Engineering Data on page 5.
2. Applicable Load
Use the following formula to calculate the maximum total capacity of a heater load for a three-phase balanced load with delta connections.
Maximum load capacity = Load current × Load voltage ×
Example: 15 A × 200 V × 3 = 5.196 W ≅ 5.1 kW
Example: 15 A × 400 V × 3 = 10.392 W ≅ 10.3 kW
3
Main Circuit of Models with Externally Attached Heat Sinks
G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB
-215B -215B -225B -225B -235B -235B -245B -245B -515B -515B -525B -525B -535B -535B -545B -545B
-3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD
Model
Item
Rated load
voltage
100 to 240 VAC
200 to 480 VAC
Load voltage 75 to 264 VAC
range
180 to 528 VAC
Applicable
load current
(See note.)
15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C)
Minimumload 0.2 A
current
0.5 A
Inrush
150 A (60 Hz, 220 A (60 Hz, 440 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
260 A2s
440 A (60 Hz, 1 cycle)
1,260 A2s
current
1 cycle)
1 cycle)
resistance
(peak value)
121 A2s
260 A2s
1,260 A2s
Permissible
I2t (half 60-Hz
wave)
Applicable
load(resistive
load, AC1)
Refer to Engineering Data on page 5.
Note: The applicable load current depends on the heat sink that is connected and the ambient temperature.
For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5.
3
G3PB-2N/-3N
■ Characteristics
Models with Built-in Heat Sinks
G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB-
215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B-
3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD
Item
Operate time 1/2 of load power source cycle + 1 ms max.
Release time 1/2 of load power source cycle + 1 ms max.
Output ON
voltage drop
1.6 V (RMS) max.
1.8 V (RMS) max.
Leakage
current
(See note.)
10 mA (at 200 VAC)
20 mA (at 480 VAC)
Insulation
resistance
100 MΩ min. (at 500 VDC)
Dielectric
strength
2,500 VAC, 50/60 Hz for 1 min
Vibration
Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track)
Destruction: 294 m/s2 (98 m/s2 with reverse mounting)
resistance
Shock resis-
tance
Ambient
operating
temperature
Operating: –30°C to 80°C (with no icing or condensation)
Storage: –30°C to 100°C (with no icing or condensation)
Ambient
operating
humidity
Operating: 45% to 85%
Weight
Approx.
1.25 kg
Ap-
Ap-
Ap-
Ap-
Ap-
Ap-
Approx.
Ap-
Ap-
Ap-
Ap-
Ap-
Ap-
prox. prox. prox. prox. prox. prox. 1.25 kg
prox. prox. prox. prox. prox. prox.
1.45
kg
1.25
kg
1.65
kg
1.45
kg
2.0 kg 1.65
kg
1.45
kg
1.25
kg
1.65
kg
1.45
kg
2.0 kg 1.65
kg
Certified
standards
UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE
(From April 2001)
EMC
Emission: EN55011 Group 1 Class B
Immunity: EN61000-6-2
Note: The leakage current of phase S will be approximately 3 times larger if the 2-element model is applied.
Models with Externally Attached Heat Sinks
G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB
-215B -215B -225B -225B -235B -235B -245B -245B -515B -515B -525B -525B -535B -535B -545B -545B
-3H-VD -2H-VD -3H-VD -2HVD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD
Model
Item
Operate time 1/2 of load power source cycle + 1 ms max.
Release time 1/2 of load power source cycle + 1 ms max.
Output ON
voltage drop
1.6 V (RMS) max.
1.8 V (RMS) max.
Leakage
current
(See note.)
10 mA (at 200 VAC)
20 mA (at 480 VAC)
Insulation
resistance
100 MΩ min. (at 500 VDC)
Dielectric
strength
2,500 VAC, 50/60 Hz for 1 min
Vibration
resistance
Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Destruction: 294 m/s2 (98 m/s2 with reverse mounting)
–30°C to 100°C (with no icing or condensation)
–30°C to 80°C (with no icing or condensation)
Shock
resistance
Storage
temperature
Ambient
operating
temperature
Ambient
storage
humidity
45% to 85%
Weight
Approx. 300 g
Note: The leakage current of phase S will be approximately 3 times larger if the 2-element model is used.
4
G3PB-2N/-3N
Engineering Data
Load Current vs. Ambient Temperature
Models with Built-in Heat Sinks
G3PB-215B-3N-VD
G3PB-215B-2N-VD
30
G3PB-225B-3N-VD
G3PB-225B-2N-VD
G3PB-235B-3N-VD
G3PB-235B-2N-VD
30
50
Derating curve under UL standard
Derating curve under UL standard
25
25
40
35
22
20
20
15
30
28
Derating curve under
UL standard
10
20
14
10
8
7
6
10
8
0
0
0
-30 -20
0
20 25 40
60
80
100
−30 −20
0
20 25 40
60
80
100
−30 −20
20
40
60
80 100
0
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
Note: 1. Please use proper ventilation and cooling.
2. Please note that the derating curve above 28 A is
applicable under the UL standard only with forced
air cooling by fan.
G3PB-245B-3N-VD
G3PB-245B-2N-VD
G3PB-515B-3N-VD
G3PB-515B-2N-VD
G3PB-525B-3N-VD
G3PB-525B-2N-VD
30
50
30
Derating curve under UL standard
45
42
40
Derating curve under UL standard
25
25
22
20
20
15
30
Derating curve under
UL standard
20
18
10
10
8
12
10
7
6
0
0
0
−30 −20
0
20 25 40
60
80
100
−30 −20
20
40
60
80 100
0
0
20 25 40
60
80
100
−30 −20
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
Note: 1. Please use proper ventilation and cooling.
Note: 1. Please use proper ventilation and cooling.
2. Please note that the derating curve above 22 A is
applicable under the UL standard only with forced
air cooling by fan.
2. Please note that the derating curve above 42 A is
applicable under the UL standard only with forced
air cooling by fan.
G3PB-535B-3N-VD
G3PB-535B-2N-VD
G3PB-545B-3N-VD
G3PB-545B-2N-VD
50
50
Derating curve under UL standard
Derating curve under UL standard
45
42
40
40
35
30
30
28
20
18
20
14
12
10
10
8
0
0
−30 −20
0
20 25 40
60
80
100
−30 −20
0
20 25 40
60
80
100
Ambient temperature (°C)
Ambient temperature (°C)
Note: 1. Please use proper ventilation and cooling.
2. Please note that the derating curve above 28 A is
applicable under the UL standard only with forced
air cooling by fan.
Note: 1. Please use proper ventilation and cooling.
2. Please note that the derating curve above 42 A is
applicable under the UL standard only with forced
air cooling by fan.
5
G3PB-2N/-3N
Load Current vs. Ambient Temperature
Models without Built-in Heat Sinks
G3PB-215B-3H(-2H)-VD
G3PB-225B-3H(-2H)-VD
G3PB-515B-3H(-2H)-VD
G3PB-525B-3H(-2H)-VD
G3PB-235B-3H(-2H)-VD
G3PB-245B-3H(-2H)-VD
G3PB-535B-3H(-2H)-VD
G3PB-545B-3H(-2H)-VD
10
10
Derating curve under UL standard
G3PB-225B-3(-2)H-VD
G3PB-525B-3(-2)H-VD
8
8
6
Derating curve under UL standard
6
5
4
5
4
G3PB-215B-3(-2)H-VD
G3PB-515B-3(-2)H-VD
2
2
1.5
1.5
0
0
0
20
40
60
80 100
−30 −20
−30 −20
20 25 40
60
80
100
0
Ambient temperature (°C)
Ambient temperature (°C)
Note: Please use proper ventilation and cooling.
Note: Please use proper ventilation and cooling.
Input Voltage vs. Input Current and Input Voltage vs. Input Impedance
Input current
Input impedance
Input voltage (V)
One Cycle Surge Current: Non-repetitive
Note: Keep the inrush current to half the rated value if it occurs repetitively.
G3PB-215B-3N/3H-VD
G3PB-215B-2N/2H-VD
G3PB-225B-3N/3H-VD
G3PB-225B-2N/2H-VD
G3PB-515B-3N/3H-VD
G3PB-515B-2N/2H-VD
G3PB-525B-3N/3H-VD
G3PB-525B-2N/2H-VD
G3PB-235B-3N/3H-VD
G3PB-235B-2N/2H-VD
G3PB-245B-3N/3H-VD
G3PB-245B-2N/2H-VD
G3PB-535B-3N/3H-VD
G3PB-535B-2N/2H-VD
G3PB-545B-3N/3H-VD
G3PB-545B-2N/2H-VD
Energized time (ms)
Energized time (ms)
Energized time (ms)
6
G3PB-2N/-3N
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3PB-215B-3N-VD
G3PB-215B-2N-VD
G3PB-225B-2N-VD
G3PB-515B-3N-VD
G3PB-515B-2N-VD
G3PB-525B-2N-VD
Without Terminal Cover
Two, 4.6-dia. mounting holes
With Terminal Cover
Four, 8 dia.
Two, M3.5
80.5
max.
100
max.
24 68
90
Two, R2.3
mounting
holes
0.5
64
20 20
32.2
80 max.
Six, M4
68
Mounting Hole Dimensions
30.5
max.
19.4
64 0.3
14.6
90 0.3
120 max.
Four, 4.5-dia. or M4
Terminal Arrangement/Internal Connections
G3PB-2@5B-2N-VD G3PB-515B-3N-VD
G3PB-215B-3N-VD
G3PB-5@5B-2N-VD
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
G3PB-225B-3N-VD
G3PB-235B-2N-VD
G3PB-525B-3N-VD
G3PB-535B-2N-VD
Without Terminal Cover
With Terminal Cover
Two, 4.6-dia. mounting holes
Four, 8 dia.
Two, M3.5
80.5
120
max.
24 68
100 110
max.
Two, R2.3
mounting
holes
0.5
64
Six, M5 (35 A type)
Six, M4 (25 A type)
20 20
32.2
80 max.
68
Mounting Hole Dimensions
30.5
max.
64 0.3
19.4
14.6
110 0.3
120 max.
Four, 4.5-dia. or M4
Terminal Arrangement/Internal Connections
G3PB-235B-2N-VD G3PB-525B-3N-VD
G3PB-225B-3N-VD
G3PB-535B-2N-VD
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
7
G3PB-2N/-3N
G3PB-235B-3N-VD
G3PB-245B-2N-VD
G3PB-535B-3N-VD
G3PB-545B-2N-VD
Without Terminal Cover
With Terminal Cover
Two, 4.6-dia. mounting holes
Four, 8 dia.
Two, M3.5
24 68
80.5
140
max.
120 130
max.
Two, R2.3
mounting
holes
0.5
Six, M5
20 20
32.2
68
64
80 max.
Mounting Hole Dimensions
30.5
19.4 max.
64 0.3
14.6
120 max.
130 0.3
Four, 4.5-dia. or M4
Terminal Arrangement/Internal Connections
G3PB-245B-2N-VD G3PB-535B-3N-VD
G3PB-235B-3N-VD
G3PB-545B-2N-VD
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
G3PB-245B-3N-VD
G3PB-545B-3N-VD
Without Terminal Cover
Two, 4.6-dia. mounting holes
Four, 8 dia.
With Terminal Cover
Two, M3.5
80.5
max.
140
120 130
max.
24 68
Two, R2.3
mounting
holes
Six, M5
0.5
64
20 20
32.2
68
80 max.
110 max.
Mounting Hole Dimensions
30.5
max.
64 0.3
19.4
14.6
120 max.
130 0.3
Terminal Arrangement/Internal Connections
G3PB-245B-3N-VD G3PB-545B-3N-VD
Four, 4.5-dia. or M4
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
8
G3PB-2N/-3N
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
9
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
·
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.