Solid State Contactors (New Heat Sink Construction)  
G3PB-2N/-3N  
CSM_G3PB-2N_-3N_DS_E_2_1  
Space and working time saved with new heat  
sink construction. Series now includes  
480-VAC models to allow use in a greater  
range of applications.  
• A comprehensive lineup that now includes 480-VAC models.  
• Slim design with 3-phase output and built-in heat sinks.  
• New heat sink construction with smaller mounting section.  
• DIN track mounting supported as standard. (Screw mounting is  
also possible.)  
• Certified by UL, CSA, and VDE.  
Refer to Safety Precautions for All Solid State  
Relays.  
Model Number Structure  
Model Number Legend  
G3PB-@@@-@@-@  
2 3 4 5 6  
7
1
1. Basic Model Name  
G3PB: Solid State Relay  
2. Rated Load Power Supply Voltage  
2:  
5:  
200 VAC  
480 VAC  
3. Rated Load Current  
15:  
25:  
35:  
45:  
15 A  
25 A  
35 A  
45 A  
4. Terminal Type  
B:  
Screw terminals  
5. Single-phase/3-phase and Number of Elements for 3-phase  
2:  
3:  
3-phase, 2-element models  
3-phase, 3-element models  
6. 3-phase Type  
N:  
H:  
DIN track mounting and built-in heat sink  
No heat sink (“hockey puck” type)  
7. Certification  
VD: Certified by UL, CSA, and VDE  
1
G3PB-2N/-3N  
Ordering Information  
Solid State Contactors  
Models with Built-in Heat Sinks  
Applicable  
phase  
Main circuit voltage  
Zero cross  
function  
Applicable load current  
(with Class-1 AC resistive load)  
Number of  
poles  
Model  
3
100 to 240 VAC  
Yes  
15 A  
3
G3PB-215B-3N-VD DC12-24  
G3PB-215B-2N-VD DC12-24  
G3PB-225B-3N-VD DC12-24  
G3PB-225B-2N-VD DC12-24  
G3PB-235B-3N-VD DC12-24  
G3PB-235B-2N-VD DC12-24  
G3PB-245B-3N-VD DC12-24  
G3PB-245B-2N-VD DC12-24  
G3PB-515B-3N-VD DC12-24  
G3PB-515B-2N-VD DC12-24  
G3PB-525B-3N-VD DC12-24  
G3PB-525B-2N-VD DC12-24  
G3PB-535B-3N-VD DC12-24  
G3PB-535B-2N-VD DC12-24  
G3PB-545B-3N-VD DC12-24  
G3PB-545B-2N-VD DC12-24  
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
25 A  
35 A  
45 A  
15 A  
25 A  
35 A  
45 A  
200 to 480 VAC  
Note: The applicable load current depends on the ambient temperature. When ordering, specify the rated input voltage.  
Models with Externally Attached Heat Sinks  
Applicable  
phase  
Main circuit voltage  
Zero cross  
function  
Applicable load current  
(See note.)  
Number of  
poles  
Model  
3
100 to 240 VAC  
Yes  
15 A  
25 A  
35 A  
45 A  
15 A  
25 A  
35 A  
45 A  
3
G3PB-215B-3H-VD DC12-24  
G3PB-215B-2H-VD DC12-24  
G3PB-225B-3H-VD DC12-24  
G3PB-225B-2H-VD DC12-24  
G3PB-235B-3H-VD DC12-24  
G3PB-235B-2H-VD DC12-24  
G3PB-245B-3H-VD DC12-24  
G3PB-245B-2H-VD DC12-24  
G3PB-515B-3H-VD DC12-24  
G3PB-515B-2H-VD DC12-24  
G3PB-525B-3H-VD DC12-24  
G3PB-525B-2H-VD DC12-24  
G3PB-535B-3H-VD DC12-24  
G3PB-535B-2H-VD DC12-24  
G3PB-545B-3H-VD DC12-24  
G3PB-545B-2H-VD DC12-24  
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
200 to 480 VAC  
Note: The applicable load current depends on the heat sink that is connected and the ambient temperature.  
For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5.  
2
G3PB-2N/-3N  
Specifications  
Ratings (at an Ambient Temperature of 25°C)  
Operating Circuit (Common)  
Item  
Common  
Rated voltage  
Operating voltage range  
12 to 24 VDC  
9.6 to 30 VDC  
Rated input current (Impedance) 10 mA max. (at 24 VDC)  
Must operate voltage  
Must release voltage  
Insulation method  
Operation indicator  
9.6 VDC max.  
1 VDC min.  
Phototriac coupler  
Yellow LED  
Main Circuit of Models with Built-in Heat Sinks  
G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB-  
215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B-  
3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD  
Model  
Item  
Rated load voltage 100 to 240 VAC  
Load voltage range 75 to 264 VAC  
200 to 480 VAC  
180 to 528 VAC  
Applicable load  
current  
(See note 1.)  
15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C)  
Minimum load cur- 0.2 A  
rent  
0.5 A  
Inrush current re- 150 A  
220 A  
440 A  
220 A  
(60 Hz, 1 cycle)  
440 A  
(60 Hz, 1 cycle)  
sistance  
(60 Hz, 1 cy- (60 Hz, 1 cy- (60 Hz, 1 cycle)  
(peak value)  
cle)  
cle)  
Permissible I2t  
(half 60-Hz wave)  
121 A2s  
260 A2s  
1260 A2s  
260 A2s  
1260 A2s  
Applicable load  
(resistive load,  
AC1) (See note 2.)  
5.1 kW max. 8.6 kW max. 12.1 kW max. 15.5 kW max. 12.5 kW max. 20.7 kW max. 29.0 kW max. 37.4 kW max.  
(at 200 VAC) (at 200 VAC) (at 200 VAC) (at 200 VAC) (at 480 VAC) (at 480 VAC) (at 480 VAC) (at 480 VAC)  
Note: 1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in  
Engineering Data on page 5.  
2. Applicable Load  
Use the following formula to calculate the maximum total capacity of a heater load for a three-phase balanced load with delta connections.  
Maximum load capacity = Load current × Load voltage ×  
Example: 15 A × 200 V × 3 = 5.196 W 5.1 kW  
Example: 15 A × 400 V × 3 = 10.392 W 10.3 kW  
3
Main Circuit of Models with Externally Attached Heat Sinks  
G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB  
-215B -215B -225B -225B -235B -235B -245B -245B -515B -515B -525B -525B -535B -535B -545B -545B  
-3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD  
Model  
Item  
Rated load  
voltage  
100 to 240 VAC  
200 to 480 VAC  
Load voltage 75 to 264 VAC  
range  
180 to 528 VAC  
Applicable  
load current  
(See note.)  
15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C)  
Minimumload 0.2 A  
current  
0.5 A  
Inrush  
150 A (60 Hz, 220 A (60 Hz, 440 A (60 Hz, 1 cycle)  
220 A (60 Hz, 1 cycle)  
260 A2s  
440 A (60 Hz, 1 cycle)  
1,260 A2s  
current  
1 cycle)  
1 cycle)  
resistance  
(peak value)  
121 A2s  
260 A2s  
1,260 A2s  
Permissible  
I2t (half 60-Hz  
wave)  
Applicable  
load(resistive  
load, AC1)  
Refer to Engineering Data on page 5.  
Note: The applicable load current depends on the heat sink that is connected and the ambient temperature.  
For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5.  
3
G3PB-2N/-3N  
Characteristics  
Models with Built-in Heat Sinks  
G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB-  
215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B-  
3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD  
Item  
Operate time 1/2 of load power source cycle + 1 ms max.  
Release time 1/2 of load power source cycle + 1 ms max.  
Output ON  
voltage drop  
1.6 V (RMS) max.  
1.8 V (RMS) max.  
Leakage  
current  
(See note.)  
10 mA (at 200 VAC)  
20 mA (at 480 VAC)  
Insulation  
resistance  
100 Mmin. (at 500 VDC)  
Dielectric  
strength  
2,500 VAC, 50/60 Hz for 1 min  
Vibration  
Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track)  
Destruction: 294 m/s2 (98 m/s2 with reverse mounting)  
resistance  
Shock resis-  
tance  
Ambient  
operating  
temperature  
Operating: –30°C to 80°C (with no icing or condensation)  
Storage: –30°C to 100°C (with no icing or condensation)  
Ambient  
operating  
humidity  
Operating: 45% to 85%  
Weight  
Approx.  
1.25 kg  
Ap-  
Ap-  
Ap-  
Ap-  
Ap-  
Ap-  
Approx.  
Ap-  
Ap-  
Ap-  
Ap-  
Ap-  
Ap-  
prox. prox. prox. prox. prox. prox. 1.25 kg  
prox. prox. prox. prox. prox. prox.  
1.45  
kg  
1.25  
kg  
1.65  
kg  
1.45  
kg  
2.0 kg 1.65  
kg  
1.45  
kg  
1.25  
kg  
1.65  
kg  
1.45  
kg  
2.0 kg 1.65  
kg  
Certified  
standards  
UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE  
(From April 2001)  
EMC  
Emission: EN55011 Group 1 Class B  
Immunity: EN61000-6-2  
Note: The leakage current of phase S will be approximately 3 times larger if the 2-element model is applied.  
Models with Externally Attached Heat Sinks  
G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB  
-215B -215B -225B -225B -235B -235B -245B -245B -515B -515B -525B -525B -535B -535B -545B -545B  
-3H-VD -2H-VD -3H-VD -2HVD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD  
Model  
Item  
Operate time 1/2 of load power source cycle + 1 ms max.  
Release time 1/2 of load power source cycle + 1 ms max.  
Output ON  
voltage drop  
1.6 V (RMS) max.  
1.8 V (RMS) max.  
Leakage  
current  
(See note.)  
10 mA (at 200 VAC)  
20 mA (at 480 VAC)  
Insulation  
resistance  
100 Mmin. (at 500 VDC)  
Dielectric  
strength  
2,500 VAC, 50/60 Hz for 1 min  
Vibration  
resistance  
Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)  
Destruction: 294 m/s2 (98 m/s2 with reverse mounting)  
–30°C to 100°C (with no icing or condensation)  
–30°C to 80°C (with no icing or condensation)  
Shock  
resistance  
Storage  
temperature  
Ambient  
operating  
temperature  
Ambient  
storage  
humidity  
45% to 85%  
Weight  
Approx. 300 g  
Note: The leakage current of phase S will be approximately 3 times larger if the 2-element model is used.  
4
G3PB-2N/-3N  
Engineering Data  
Load Current vs. Ambient Temperature  
Models with Built-in Heat Sinks  
G3PB-215B-3N-VD  
G3PB-215B-2N-VD  
30  
G3PB-225B-3N-VD  
G3PB-225B-2N-VD  
G3PB-235B-3N-VD  
G3PB-235B-2N-VD  
30  
50  
Derating curve under UL standard  
Derating curve under UL standard  
25  
25  
40  
35  
22  
20  
20  
15  
30  
28  
Derating curve under  
UL standard  
10  
20  
14  
10  
8
7
6
10  
8
0
0
0
-30 -20  
0
20 25 40  
60  
80  
100  
30 20  
0
20 25 40  
60  
80  
100  
30 20  
20  
40  
60  
80 100  
0
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Note: 1. Please use proper ventilation and cooling.  
2. Please note that the derating curve above 28 A is  
applicable under the UL standard only with forced  
air cooling by fan.  
G3PB-245B-3N-VD  
G3PB-245B-2N-VD  
G3PB-515B-3N-VD  
G3PB-515B-2N-VD  
G3PB-525B-3N-VD  
G3PB-525B-2N-VD  
30  
50  
30  
Derating curve under UL standard  
45  
42  
40  
Derating curve under UL standard  
25  
25  
22  
20  
20  
15  
30  
Derating curve under  
UL standard  
20  
18  
10  
10  
8
12  
10  
7
6
0
0
0
30 20  
0
20 25 40  
60  
80  
100  
30 20  
20  
40  
60  
80 100  
0
0
20 25 40  
60  
80  
100  
30 20  
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Note: 1. Please use proper ventilation and cooling.  
Note: 1. Please use proper ventilation and cooling.  
2. Please note that the derating curve above 22 A is  
applicable under the UL standard only with forced  
air cooling by fan.  
2. Please note that the derating curve above 42 A is  
applicable under the UL standard only with forced  
air cooling by fan.  
G3PB-535B-3N-VD  
G3PB-535B-2N-VD  
G3PB-545B-3N-VD  
G3PB-545B-2N-VD  
50  
50  
Derating curve under UL standard  
Derating curve under UL standard  
45  
42  
40  
40  
35  
30  
30  
28  
20  
18  
20  
14  
12  
10  
10  
8
0
0
30 20  
0
20 25 40  
60  
80  
100  
30 20  
0
20 25 40  
60  
80  
100  
Ambient temperature (°C)  
Ambient temperature (°C)  
Note: 1. Please use proper ventilation and cooling.  
2. Please note that the derating curve above 28 A is  
applicable under the UL standard only with forced  
air cooling by fan.  
Note: 1. Please use proper ventilation and cooling.  
2. Please note that the derating curve above 42 A is  
applicable under the UL standard only with forced  
air cooling by fan.  
5
G3PB-2N/-3N  
Load Current vs. Ambient Temperature  
Models without Built-in Heat Sinks  
G3PB-215B-3H(-2H)-VD  
G3PB-225B-3H(-2H)-VD  
G3PB-515B-3H(-2H)-VD  
G3PB-525B-3H(-2H)-VD  
G3PB-235B-3H(-2H)-VD  
G3PB-245B-3H(-2H)-VD  
G3PB-535B-3H(-2H)-VD  
G3PB-545B-3H(-2H)-VD  
10  
10  
Derating curve under UL standard  
G3PB-225B-3(-2)H-VD  
G3PB-525B-3(-2)H-VD  
8
8
6
Derating curve under UL standard  
6
5
4
5
4
G3PB-215B-3(-2)H-VD  
G3PB-515B-3(-2)H-VD  
2
2
1.5  
1.5  
0
0
0
20  
40  
60  
80 100  
30 20  
30 20  
20 25 40  
60  
80  
100  
0
Ambient temperature (°C)  
Ambient temperature (°C)  
Note: Please use proper ventilation and cooling.  
Note: Please use proper ventilation and cooling.  
Input Voltage vs. Input Current and Input Voltage vs. Input Impedance  
Input current  
Input impedance  
Input voltage (V)  
One Cycle Surge Current: Non-repetitive  
Note: Keep the inrush current to half the rated value if it occurs repetitively.  
G3PB-215B-3N/3H-VD  
G3PB-215B-2N/2H-VD  
G3PB-225B-3N/3H-VD  
G3PB-225B-2N/2H-VD  
G3PB-515B-3N/3H-VD  
G3PB-515B-2N/2H-VD  
G3PB-525B-3N/3H-VD  
G3PB-525B-2N/2H-VD  
G3PB-235B-3N/3H-VD  
G3PB-235B-2N/2H-VD  
G3PB-245B-3N/3H-VD  
G3PB-245B-2N/2H-VD  
G3PB-535B-3N/3H-VD  
G3PB-535B-2N/2H-VD  
G3PB-545B-3N/3H-VD  
G3PB-545B-2N/2H-VD  
Energized time (ms)  
Energized time (ms)  
Energized time (ms)  
6
G3PB-2N/-3N  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
G3PB-215B-3N-VD  
G3PB-215B-2N-VD  
G3PB-225B-2N-VD  
G3PB-515B-3N-VD  
G3PB-515B-2N-VD  
G3PB-525B-2N-VD  
Without Terminal Cover  
Two, 4.6-dia. mounting holes  
With Terminal Cover  
Four, 8 dia.  
Two, M3.5  
80.5  
max.  
100  
max.  
24 68  
90  
Two, R2.3  
mounting  
holes  
0.5  
64  
20 20  
32.2  
80 max.  
Six, M4  
68  
Mounting Hole Dimensions  
30.5  
max.  
19.4  
64 0.3  
14.6  
90 0.3  
120 max.  
Four, 4.5-dia. or M4  
Terminal Arrangement/Internal Connections  
G3PB-2@5B-2N-VD G3PB-515B-3N-VD  
G3PB-215B-3N-VD  
G3PB-5@5B-2N-VD  
(+)  
(+)  
(+)  
(+)  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
A1  
A1  
A1  
A1  
A2  
A2  
A2  
A2  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
()  
()  
()  
()  
G3PB-225B-3N-VD  
G3PB-235B-2N-VD  
G3PB-525B-3N-VD  
G3PB-535B-2N-VD  
Without Terminal Cover  
With Terminal Cover  
Two, 4.6-dia. mounting holes  
Four, 8 dia.  
Two, M3.5  
80.5  
120  
max.  
24 68  
100 110  
max.  
Two, R2.3  
mounting  
holes  
0.5  
64  
Six, M5 (35 A type)  
Six, M4 (25 A type)  
20 20  
32.2  
80 max.  
68  
Mounting Hole Dimensions  
30.5  
max.  
64 0.3  
19.4  
14.6  
110 0.3  
120 max.  
Four, 4.5-dia. or M4  
Terminal Arrangement/Internal Connections  
G3PB-235B-2N-VD G3PB-525B-3N-VD  
G3PB-225B-3N-VD  
G3PB-535B-2N-VD  
(+)  
(+)  
(+)  
(+)  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
A1  
A1  
A1  
A1  
A2  
A2  
A2  
A2  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
()  
()  
()  
()  
7
G3PB-2N/-3N  
G3PB-235B-3N-VD  
G3PB-245B-2N-VD  
G3PB-535B-3N-VD  
G3PB-545B-2N-VD  
Without Terminal Cover  
With Terminal Cover  
Two, 4.6-dia. mounting holes  
Four, 8 dia.  
Two, M3.5  
24 68  
80.5  
140  
max.  
120 130  
max.  
Two, R2.3  
mounting  
holes  
0.5  
Six, M5  
20 20  
32.2  
68  
64  
80 max.  
Mounting Hole Dimensions  
30.5  
19.4 max.  
64 0.3  
14.6  
120 max.  
130 0.3  
Four, 4.5-dia. or M4  
Terminal Arrangement/Internal Connections  
G3PB-245B-2N-VD G3PB-535B-3N-VD  
G3PB-235B-3N-VD  
G3PB-545B-2N-VD  
(+)  
(+)  
(+)  
(+)  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
A1  
A1  
A1  
A1  
A2  
A2  
A2  
A2  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
()  
()  
()  
()  
G3PB-245B-3N-VD  
G3PB-545B-3N-VD  
Without Terminal Cover  
Two, 4.6-dia. mounting holes  
Four, 8 dia.  
With Terminal Cover  
Two, M3.5  
80.5  
max.  
140  
120 130  
max.  
24 68  
Two, R2.3  
mounting  
holes  
Six, M5  
0.5  
64  
20 20  
32.2  
68  
80 max.  
110 max.  
Mounting Hole Dimensions  
30.5  
max.  
64 0.3  
19.4  
14.6  
120 max.  
130 0.3  
Terminal Arrangement/Internal Connections  
G3PB-245B-3N-VD G3PB-545B-3N-VD  
Four, 4.5-dia. or M4  
(+)  
(+)  
L1/R  
L2/S  
L3/T  
L1/R  
L2/S  
L3/T  
A1  
A1  
A2  
A2  
T1/U  
T2/V  
T3/W  
T1/U  
T2/V  
T3/W  
()  
()  
8
G3PB-2N/-3N  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
9
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

G3PB-245B-VD

Trigger Output SSR, 1-Channel, 2500V Isolation
OMRON

G3PB-245B-VDDC12-24

Trigger Output SSR, 1-Channel
OMRON

G3PB-415B-2-VD

Trigger Output SSR, 2-Channel, 2500V Isolation
OMRON

G3PB-415B-2H-VD

Trigger Output SSR, 2-Channel, 2500V Isolation
OMRON

G3PB-415B-3-VD

Trigger Output SSR, 3-Channel, 2500V Isolation
OMRON

G3PB-415B-3H-VD

Trigger Output SSR, 3-Channel, 2500V Isolation
OMRON

G3PB-425B-2-VD

Trigger Output SSR, 2-Channel, 2500V Isolation
OMRON

G3PB-425B-2H-VD

Trigger Output SSR, 2-Channel, 2500V Isolation
OMRON

G3PB-425B-3-VD

Trigger Output SSR, 3-Channel, 2500V Isolation
OMRON

G3PB-425B-3H-VD

Trigger Output SSR, 3-Channel, 2500V Isolation
OMRON

G3PB-435B-2-VD

Trigger Output SSR, 2-Channel, 2500V Isolation
OMRON

G3PB-435B-2H-VD

Trigger Output SSR, 2-Channel, 2500V Isolation
OMRON