G3VM-21DR [OMRON]
Transistor Output SSR;型号: | G3VM-21DR |
厂家: | OMRON ELECTRONICS LLC |
描述: | Transistor Output SSR |
文件: | 总3页 (文件大小:428K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
G3VM-21AR/DR
MOS FET Relays
Higher power, 3-A switching with a 20-V
load voltage, DIP package.
Low 40 mΩ ON Resistance.
• Continuous load current of 3 A.
• Switches minute analog signals.
• Dielectric strength of 2,500 Vrms between I/O.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■Application Examples
■
Terminal Arrangement/Internal Connections
4
3
• Communication equipment
• Test & Measurement equipment
• Security equipment
∗
Mold pin mark
OMRON logo
Pin 1 mark
Model name
LOT No.
932
• Factory Automation equipment
• Power circuit
1
2
Note: The actual product is marked differently from the image shown here.
∗
The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
■List of Models
Minimum package quantity
Model
Load voltage
(peak value) *
Package type Contact form
Terminals
Number per stick Number per tape and reel
PCB terminals
G3VM-21AR
100
---
---
1a
DIP4
20 V
G3VM-21DR
(SPST-NO)
Surface-mounting terminals
G3VM-21DR (TR)
1,500
* The AC peak and DC value are given for the load voltage.
■Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol
IF
Rating
Unit
mA
A
Measurement conditions
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Pulse ON current
30
IFP
1
100 µs pulses, 100 pps
∆IF/°C
VR
−0.3
mA/°C Ta ≥ 25°C
5
V
TJ
125
°C
VOFF
IO
20
V
3
−30
A
∆IO/°C
Iop
mA/°C Ta ≥ 25°C
9
A
°C
t = 100 ms, Duty = 1/10
Connection temperature
Dielectric strength between I/O (See note 1.)
Operating temperature
Storage temperature
Soldering temperature
TJ
125
VI-O
Ta
2500
Vrms
°C
AC for 1 min
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
−40 to +85
−55 to +125
260
With no icing or condensation
With no icing or condensation
10 s
Tstg
---
°C
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
°C
■Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum Unit
Measurement conditions
IF = 10 mA
LED forward voltage
Reverse current
VF
IR
1.18
---
1.33
---
1.48
10
---
3
V
Note: 2. Turn-ON and Turn-OFF Times
µA
pF
VR = 5 V
IF
1
4
RL
Capacity between terminals
Trigger LED forward current
Maximum resistance with output ON
Current leakage when the relay is open
Capacity between terminals
Capacity between I/O terminals
Insulation resistance between I/O terminals
Turn-ON time
CT
---
70
V = 0, f = 1 MHz
IO = 1 A
VDD
VOUT
2
3
IFT
---
0.7
40
mA
mΩ
µA
pF
RON
ILEAK
COFF
CI-O
RI-O
tON
---
80
1.0
---
---
---
5
IF = 5 mA, IO = 2 A, t < 1s
VOFF = 20 V
---
---
---
300
0.8
---
V = 0, f = 1 MHz
f = 1 MHz, VS = 0 V
I
F
---
pF
1000
---
MΩ
ms
ms
VI-O = 500 VDC, ROH ≤ 60%
90%
V
OUT
1
10%
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
t
ON
tOFF
Turn-OFF time
tOFF
---
0.3
1
1
G3VM-21AR/DR
MOS FET Relays
■Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Load voltage
(AC peak/DC)
Symbol
Minimum
Typical
---
Maximum
Unit
V
VDD
IF
---
5
16
25
3
Operating LED forward current
10
mA
A
Continuous load current
(AC peak/DC)
IO
---
---
Operating temperature
Ta
−20
---
65
°C
■Engineering Data
LED forward current vs.
Ambient temperature
Continuous load current vs.
Ambient temperature
LED forward current vs.
LED forward voltage
IF - Ta
IO - Ta
IF - VF
50
4
100
10
1
Ta= 25°C
40
30
20
10
0
3
2
1
0
0.1
0.01
-40
-20
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
0
0.5
1
1.5
2
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
LED forward voltage V
F
(V)
Continuous load current vs.
On-state voltage
On-state resistance vs.
Ambient temperature
Trigger LED forward current vs.
Ambient temperature
IO - VON
RON - Ta
IFT - Ta
4
100
2
I
I
= 2A
I
= 1A
O
O
Ta = 25°C
3
= 5mA, t < 1s
t < 1s
F
I
F
= 5mA
80
60
40
20
0
2
1
0
1
-1
-2
-3
-4
-0.2
0
-40
-0.1
0
0.1
0.2
-40
-20
0
20
40
60
80
100
-20
0
20
40
60
80
100
On-state voltage VON (V)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs.
LED forward current
Turn ON, Turn OFF time vs.
Ambient temperature
Current leakage vs.
Ambient temperature
tON, tOFF - IF
tON, tOFF - Ta
ILEAK - Ta
100
100
100
V
= 20V
V
= 20V
DD
DD
V
= 20V
OFF
R
= 200Ω
R
= 200Ω
L
L
I
F
= 5mA
Ta = 25°C
10
1
10
10
1
t
t
on
off
1
t
t
off
on
0.1
0.01
0.1
0.01
0.1
0.01
1
10
100
-40
-20
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
LED forward current I
F
(mA)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
■Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
DIP4
■Appearance
DIP (DDuual IInnline Paacckkaaggee))
DIP4
Mold pin mark∗
OMRON logo
Model name
932
Pin 1 mark
LOT No.
Note: The actual product is marked differently from the image shown here.
∗ The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■Dimensions
(Unit: mm)
PCB Terminals
Surface-mounting Terminals
PCB Dimensions (Bottom View)
Weight: 0.25 g
Weight: 0.25 g
Four, 0.8-dia. holes
2.54
(0.61)
2.54
0.25
4.58
0.25
4.58
(0.61)
(1.52)
0.25
(1.52)
6.4
0.25
6.4
0.25
Actual Mounting Pad Dimensions
(Recommended Value, Top View)
7.62
0.25
0.8
0.25
7.62
3.65+−0.15
0.25
2.54
+0.15
−0.25
+0.25
+0.1
−0.05
3.65
4.0
−0.2
0.25
1.0 min.
0.15
0.1
1.2
0.5
2.5 min.
0.15
1.2
7.85 to 8.80
8.3 to 8.8
1.0 min.
10.0 max.
0.25
2.54
0.25
2.54
1.3
1.5
Note: The actual product is marked differently from the
image shown here.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K135-E1-02
0412(0412)(O)
相关型号:
©2020 ICPDF网 联系我们和版权申明