G4Q-211A [OMRON]

Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation;
G4Q-211A
型号: G4Q-211A
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation

文件: 总6页 (文件大小:369K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ratchet Relay  
G4Q  
CSM_G4Q_DS_E_3_2  
Unique Ratchet Mechanism Assures Positive  
Alternate Transfer/Switching Operation  
• Each contact in the double-pole contact mechanism performs  
alternate make-brake operation at each pulse input and is thus  
ideal for alternate operation or transfer/switching operation of a  
motor.  
• Positive operation is assured due to the unique ratchet mecha-  
nism.  
• Satisfies dielectric strength of 2,000 VAC.  
• Low power consumption.  
(AC: approx. 6.4 VA; DC: approx. 3.9 W)  
Ordering Information  
When your order, specify the rated voltage.  
Open Models  
Plug-in Models  
Item  
DPDT  
Item  
DPDT  
Model  
G4Q-211A  
Rated voltage  
24 VAC  
Model  
G4Q-212S  
Rated voltage  
12 VAC  
Basic model  
Basic model  
50 VAC  
24 VAC  
100/(110) VAC  
200/(220) VAC  
12 VDC  
50 VAC  
100/(110) VAC  
200/(220) VAC  
12 VDC  
24 VDC  
100 VDC  
24 VDC  
100 VDC  
200 VDC  
Note:  
When ordering, add the rated coil voltage (listed in Specifications) to the model number.  
Example: G4Q-211A, 24 VAC  
Rated coil voltage  
Model Number Legend  
G4Q-@@@@  
1
2
3
4
1. Contact Form  
2: DPDT  
2. Contact Type  
4. Terminal Shape  
A:  
S:  
Solder  
Plug-in  
1:  
Single  
3. Enclosure Construction  
1:  
2:  
No casing  
Casing  
1
G4Q  
Accessories (Order Separately)  
DIN track/Front-connecting Socket  
Back-connecting Socket  
Screw terminal  
Solder terminal  
8PFA1  
PL08  
Specifications  
Coil Ratings  
Item  
Current (mA)  
60 Hz  
531  
Resistance () Must operate Must release  
Max. voltage  
Power consumption  
Initial Rated  
Approx. Approx.  
13.5 VA 6.4 VA  
Rated voltage (V) 50 Hz  
% of rated voltage  
AC  
12  
24  
50  
614  
307  
148  
74  
2.24  
8.7  
80 % max.  
10 % min.  
110 % max.  
266  
128  
42.7  
100/  
64/73.5 160  
(110)  
200/  
37  
32/36.8 671  
(220)  
Item  
Current (mA)  
60 Hz  
Resistance () Must operate Must release  
Max. voltage  
Power consumption  
Approx. 3.9 W  
Rated voltage (V) 50 Hz  
% of rated voltage  
12  
320  
155  
39  
37.5  
5 % min.  
DC  
24  
155  
100  
200  
2,580  
10,400  
19.2  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and  
15% for DC coil resistance.  
2. The AC coil resistance values are for reference only.  
3. Performance characteristic data is measured at a coil temperature of 23°C.  
4. The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.  
5. The AC power consumption is measured at 60 Hz.  
Contact Ratings  
Load  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4)  
(L/R = 7 ms)  
Contact mechanism  
Contact material  
Single  
Silver alloy  
Rated load  
5 A at 220 VAC, 5 A at 24 VDC  
3 A at 220 VAC, 4 A at 24 VDC  
Rated carry current  
Max. switching voltage  
Max. switching current  
5 A  
250 VAC, 250 VDC  
5 A  
2
G4Q  
Characteristics  
Contact resistance (See note 2.)  
Operate time (See note 3.)  
Max. operating frequency  
50 mmax.  
60 ms max.  
Mechanical: 1,200 operations/hr  
Electrical:  
1,200 operations/hr (under rated load)  
Insulation resistance (See note 4.)  
Dielectric strength  
100 Mmin. (at 500 VDC)  
2,000 VAC, 50/60 Hz for 1 min between coil and contact (1,000 VAC, 50/60 Hz for 1 min between con-  
tacts of same polarity) (2,000 VAC between contacts of different polarities)  
Vibration resistance  
Shock resistance  
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)  
Destruction: 500 m/s2  
Malfunction: 100 m/s2  
Endurance  
Mechanical:  
Electrical:  
5,000,000 operations min. (at operating frequency of 1,200 operations/hr)  
500,000 operations min. (under rated load and at operating frequency of  
1,200 operations/hr) (See note 5.)  
Error rate (See note 6.)  
Ambient temperature  
Ambient humidity  
Weight  
1 A at 5 VDC (0.1 A at 5 VDC)  
Operating:  
Operating:  
–10°C to 55°C (with no icing or no condensation)  
5% to 85%  
Open model: Approx. 240 g; cased model: Approx. 340 g  
Note: 1. The data shown above are initial values.  
2. The contact resistance was measured with 0.1 A at 5 VDC using the voltage drop method.  
3. The operate time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23°C.  
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric  
strength.  
5. The electrical endurance was measured at an ambient temperature of 23°C.  
6. This value was measured at a switching frequency of 60 operations per minute. The value in parentheses is for the cased model.  
Engineering Data  
Electrical Endurance  
Maximum Switching Power  
10,000  
7,000  
5,000  
DC resistive load  
AC resistive load  
220 VAC resistive load  
24 VDC resistive load  
3,000  
AC inductive load  
(cosφ = 0.4)  
24VDC inductive load  
L/R = 7 ms  
1,000  
700  
500  
DC inductive load  
L/R = 7 ms  
300  
100  
70  
50  
220 VAC inductive load  
(cosφ = 0.4)  
30  
Switching current (A)  
Switching voltage (V)  
3
G4Q  
Ambient Temperature vs.  
Coil Temperature Rise  
100 VAC 50 Hz  
Malfunctioning Shock  
24 VDC  
Contact carry current: 5 A  
Contact carry current: 5 A  
Contact with no carry current  
Contact with no carry current  
Not  
energized  
Energized  
Unit: m/s2  
Ambient temperature (°C)  
Ambient temperature (°C)  
Shock direction  
Number of samples: 5  
Measurement conditions:  
Impose a shock of  
100 m/s2 in the X, Y, and  
Z directions three times  
each with the Relay  
energized and not  
energized to check the  
shock values that cause  
the Relay to malfunction.  
Operation  
Operation Timing Chart  
100 ms min.  
Coil terminal  
Contact terminal  
(NO) (13, 86)  
Contact terminal  
(NC) (14, 85)  
Note: When a pulse for application to the coil is used, such a pulse  
should have a width of 100 ms or more. If a pulse is applied with  
a width less than the operate time, the cam may fail to rotate  
fully.  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Mounting Holes  
Terminal Arrangement/  
Internal Connections  
Open Model  
G4Q-211A  
58 0.2  
66.5 max. 58  
Four, M3 mounting  
screw holes or four  
3.5-dia. holes  
25 0.2  
Four, 3.5-dia.  
mounting holes  
25  
56 max.  
65 max.  
4
G4Q  
Plug-in Terminal Model  
G4Q-212S  
Terminal Arrangement/  
Internal Connections  
3.5  
(Bottom view)  
92.5  
max.  
71.5  
max.  
7
30.5  
80 max.  
63.5 max.  
Relay Mounting Height with Socket  
With Front-connecting  
Socket  
With Back-connecting  
Socket  
G4Q-  
212S  
100  
102  
G4Q-  
212S  
80  
8PFA1  
PL08  
Safety Precautions  
Refer to Safety Precautions for All Relays.  
Surface Mounting Socket  
Be sure to provide a mounting space according to the width of the  
Relay. The width of the Relay is 63.5 mm and the width of the Socket  
is 51 mm.  
Mounting  
Mount the Relay so that the coil faces upward and the cam faces  
downwards with the mounting plate secured vertically. Do not  
change the cam angle.  
Make sure that Relay terminals are free of flux or any other foreign  
substance before soldering the Relay terminals.  
Coil  
Cam  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
5
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron  
disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER  
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at  
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount  
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,  
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products  
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate  
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall  
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,  
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above  
warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself  
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,  
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product  
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence  
thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate  
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our  
practice to change part numbers when published ratings or features are changed, or when significant construction changes are  
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers  
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at  
any time to confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
2015.10  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2015 All Right Reserved.  

相关型号:

G4Q-211A DC24

RELAY GEN PURPOSE DPDT 5A 24V
OMRON

G4Q-212S

Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation
OMRON

G4Q-212S AC24

RELAY GEN PURPOSE DPDT 5A 24V
OMRON

G4Q-212S DC12

RELAY GEN PURPOSE DPDT 5A 12V
OMRON

G4Q-212S DC24

RELAY GEN PURPOSE DPDT 5A 24V
OMRON

G4SB60

SINGLE PHASE GLASS PASSIVATED BRIDGE RECTIFIER Voltage: 600 to 800V Current: 4.0A
GULFSEMI

G4SB80

SINGLE PHASE GLASS PASSIVATED BRIDGE RECTIFIER Voltage: 600 to 800V Current: 4.0A
GULFSEMI

G4W

PCB Power Relay
OMRON

G4W-11123A-US-TV5-100VDC

Power/Signal Relay, SPST, Momentary, 0.008A (Coil), 100VDC (Coil), 800mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON

G4W-11123A-US-TV5-12VDC

Power/Signal Relay, SPST, Momentary, 0.067A (Coil), 12VDC (Coil), 800mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON

G4W-11123A-US-TV5-24VDC

Power/Signal Relay, SPST, Momentary, 0.033A (Coil), 24VDC (Coil), 800mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON

G4W-11123A-US-TV5-Z12VDC

Power/Signal Relay, SPST, Momentary, 0.067A (Coil), 12VDC (Coil), 800mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON