G4W
PCB Power Relay
Impulse Withstand Voltage as High as
10kV with 4kV Dielectric Strength:
Ideal for Power Supply Switching
• Input and output (between coil and contacts) are completely separated, with
impulse withstand voltage of 10,000 V.
• Insulation distance of 8 mm min. between coil and contacts satisfies the VDE
Standard C/250 insulation requirements, and conforms to Electrical Appliance and
Material Safety Law with dielectric strength of 4,000 VAC min. Standard model
conforms to UL/CSA standards.
• VDE standard approved models are also available. Consult your Omron sales
representative for availability.
• SPST-NO (1a) types conform to TV-8 rating, and DPST-NO (2a) types conform to TV-5 rating.
• Full-wave bridge rectifier compatible models are also available.
RoHS Compliant
G
4
W
■Model Number Legend
G4W-@-@@@@-@-@-@
■Application Examples
• Power supplies
—
— — — —
—
—
—
1
2 3 4 5
6
7
8
1. Number of poles
1: 1-pole/SPST-NO (1a)
2: 2-pole/DPST-NO (2a)
3. Contact Type
1: Single
6. Approved Standards
US: UL, CSA
8. Classification
None: Standard
Z
: Full-wave rectifier
4. Enclosure rating
2: Unsealed
7. TV Ratings
TV5: TV-5
TV8: TV-8
2. Contact Form
1: SPST-NO (1a)
2: DPST-NO (2a)
5. Terminals
P: Straight PCB
■Ordering Information
●Gerenal-purpose Models (UL, CSA certified)
Contact form
Classification
SPST-NO (1a)
Rated coil voltage
DPST-NO (2a)
Minimum packing unit
50 pcs/tray
Model
Model
Rated coil voltage
12 VDC
24 VDC
12 VDC
24 VDC
Standard
G4W-1112P-US-TV8
G4W-2212P-US-TV5
100 VDC
100 VDC
Note: Contact your OMRON sales representative for fully sealed models.
●Full-wave Rectifier Models (UL, CSA certified)
Contact form
Classification
SPST-NO (1a)
Rated coil voltage
DPST-NO (2a)
Minimum packing unit
50 pcs/tray
Model
Model
Rated coil voltage
12 VDC
12 VDC
24 VDC
Standard
G4W-1112P-US-TV8-Z
G4W-2212P-US-TV5-Z
24 VDC
100 VDC
100 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G4W-1112P-US-TV8 DC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
1
G4W
■Ratings
PCB Power Relay
■Characteristics
●Coil
Contact resistance *1
Operate time
30 m
20 ms max.
5 ms max.
18,000 operations/hr
1,800 operations/hr
Ω
max.
Must
operate release
voltage voltage
(V)
Must
Item
Max.
voltage
(V)
Release time
Max. operating
frequency
Rated
current resistance
(mA)
Coil
Power
consumption
(mW)
Mechanical
Electrical
(V)
Rated
voltage
12 VDC
24 VDC
(Ω)
180
720
12,500
Insulation resistance *2
100 MΩ max.
ꢀ of rated voltage
Between coil and
66.7
33.3
8
4,000 VAC, 50/60 Hz for 1 min
1,500 VAC, 50/60 Hz for 1 min
2,000 VAC, 50/60 Hz for 1 min
10,000 V
contacts
80ꢀ
max.
10ꢀ
min.
130ꢀ
(at 23°C)
Approx.
0.8 W
Dielectric
strength
Between contacts of
the same polarity
Between contacts of
different polarities
Between coil and
100 VDC
Note 1. The rated current and coil resistance are measured at a coil
temperature of 23°C with a tolerance of ±15ꢀ.
2.The operating characteristics are measured at a coil temperature of
23°C.
Impulse
withstand voltage contacts
3.The “Max. voltage” is the maximum voltage that can be applied to the
relay coil.
Insulation
distance
Between coil and
contacts
Clearance: 8 mm, Creepage: 8 mm
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
1,000 m/s2
●Contacts
Destruction
Vibration
resistance
Contact form
Load
Item
SPST-NO (1a)
Resistive load Inductive load
(cos = 1) (cos = 0.4)
Ag-Alloy (Cd free)
15 A at 250 VAC 10 A at 250 VAC 10 A at 250 VAC 7.5 A at 250 VAC
DPST-NO (2a)
Resistive load Inductive load
(cos = 1) (cos = 0.4)
Malfunction
φ
φ
φ
φ
Destruction
Malfunction
Shock resistance
Durability
150 m/s2
Contact material
5,000,000 operations min.
(at 18,000 operations/hr)
100,000 operations min.
Mechanical
Rated load
15 A at 24 VDC
7.5 A at 24 VDC
10 A at 24 VDC
5 A at 24 VDC
Rated carry
current
Max. switching
voltage
Max. switching
current
Electrical
15 A
10 A
(rated load, at 1,800 operations/hr)
Failure rate (P level) (reference value) *3 100 mA at 5 VDC
250 VAC, 125 VDC
Ambient operating temperature
Ambient operating humidity
Weight
-25°C to 55°C (with no icing or condensation)
5ꢀ to 85ꢀ
Approx. 29 g
15 A
10 A
Note: The above values are initial values.
G
4
W
*1. The contact resistance was measured with 1 A at 5 VDC with a
fall-of-potential method.
*2. The insulation resistance was measured with a 500 VDC Megger Tester
applied to the same parts as those for checking the dielectric strength.
*3. This value was measured at a switching frequency of 120 operations/min.
■Engineering Data
●Maximum Switching Capacity
●Durability
SPST-NO (1a)
DPST-NO (2a)
SPST-NO (1a) AC Load
DPST-NO (2a) AC Load
100
100
1,000
1,000
(AC Load)
(AC Load)
50
50
30
AC resistive load
500
500
300
30
AC resistive load
300
15
10
250 VAC resistive load (cosφ = 1)
AC
10
inductive
load
AC
250 VAC resistive load (cosφ = 1)
inductive
load
(cosφ = 0.4)
5
3
5
3
250 VAC inductive load (cosφ = 0.4)
(cosφ = 0.4)
100
100
DC resistive load
DC resistive load
250 VAC inductive load (cosφ = 0.4)
50
30
50
30
1
1
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
0.5
0.3
0.5
0.3
0.1
0.1
10
10
0
2
4
6
8
10
12
14 1516
0
2
4
6
7.5
8
10
12
14
16
1
3
5
10
30 50 100
300 500 1,000
1
3
5
10
30 50 100
300 500 1,000
Switching current (A)
Switching current (A)
Switching voltage (V)
Switching voltage (V)
●Ambient Temperature vs.
Must Operate and Must
Release Voltage
●Durability
●Ambient Temperature vs.
SPST-NO (1a) DC Load
DPST-NO (2a) DC Load
Maximum Coil Voltage
G4W-2212P-US-TV5
1,000
1,000
200
180
100
(DC Load)
(DC Load)
Must operate voltage
Must release voltage
Sample:
G4W-2212P-US-TV5
Number of Relays: 5 pcs
500
500
80
60
40
20
300
300
24 VDC resistive load
160
24 VDC resistive load
24 VDC inductive load (L/R = 7 ms)
24 VDC inductive load (L/R = 7 ms)
140
130
120
110
100
110 VDC resistive load
100
100
110 VDC resistive load
110 VDC inductive load (L/R = 7 ms)
110 VDC inductive load (L/R = 7 ms)
50
50
30
30
10
80
0
10
0
−40
0
2
4
6
8
10
12
14 16
0
2
4
6
8
10
12
14 16
0
20
30
40
50 55 60
70
80
90
−20
0
20
40
60
80
Switching current (A)
Switching current (A)
Ambient temperature (°C)
Ambient temperature (°C)
Note: The maximum coil voltage refers to
the maximum value in a varying
range of operating power voltage,
not a continuous voltage.
●Shock Malfunction
Y
1,000
Energized
800
600
400
200
1,000
X
Z
1,000
800
G4W-1112P-US-TV8
Number of Relays: 5 pcs
200
400
600
800
Shock direction
X'
Test Conditions: Shock is applied in ±X, ±±, and ±Z directions three
times each with and without energizing the Relays
to check the number of contact malfunctions.
Standard value: 150 m/s2
700
X
1,000
X'
Z'
Y
1,000
Z
Z'
Y'
1,000
Y'
Unit: m/s2
2
G4W
■Dimensions
PCB Power Relay
Standard model
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
G4W-1112P-US-TV8(-Z)
2.54 Two, 1.2-dia. holes Two, 1.8-dia. holes
2.54
5
6
(4.67)
10.16
1
30.5 max.
(29.8)*
19.5 max.
(18.8)*
4
(4.67)
(No coil polarity)
30.5 max.
(30.0)*
(5)
15.24
7.62
(2.64)
G4W-2212P-US-TV5(-Z)
This illustration is the
G4W-2212P-US-TV5 model.
2.54 Two, 1.2-dia. holes Four, 1.8-dia. holes
0.75 0.5
1.5
1.5
5
2.54
0.1
10.16
(4.67)
10.16
5
6
3
1
2
* Average value
4
(4.67)
(No coil polarity)
G
4
W
(5)
15.24
7.62
(2.64)
■Approved Standards
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL Recognized:
(File No. E41643)
Model
Number of poles
Coil ratings
Contact ratings
15 A, 250 VAC (General Use) at 40°C
15A, 24 VDC at 40°C
Number of test operations
6,000
TV-8 at 40°C
25,000
G4W-1112( )
-US-TV8(-Z)
1
1/2HP, 125 VAC at 40°C
3/4HP, 240 VAC at 40°C
1HP, 250 VAC at 40°C
15 A, 250 VAC (General Use) at 40°C
15A, 36 VDC at 40°C
1,000
12 to 100 VDC
6,000
TV-5 at 40°C
25,000
G4W-2212( )
-US-TV5(-Z)
2
1/4HP, 125 VAC at 40°C
1/2HP, 250 VAC at 40°C
1/3HP, 125 VAC at 40°C
1/4HP, 250 VAC at 40°C
1,000
CSA Certified:
(File No. LR31928)
Number of poles
Model
Coil ratings
Contact ratings
15 A, 250 VAC (General Use) at 40°C
15A, 24 VDC at 40°C
Number of test operations
6,000
TV-8 at 40°C
25,000
G4W-1112( )-US-TV8(-Z)
1
1/2HP, 125 VAC at 40°C
3/4HP, 240 VAC at 40°C
1,000
6,000
1HP, 250 VAC at 40°C
12 to 100 VDC
15 A, 250 VAC (General Use) (Same Polarity) at 40°C
10 A, 250 VAC (General Use) at 40°C
15A, 24 VDC at 40°C
G4W-2212( )-US-TV5(-Z)
2
TV-5 at 40°C
25,000
1,000
1/2HP, 250 VAC at 40°C
1/3HP, 125 VAC at 40°C
3
G4W
PCB Power Relay
■ Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Mounting
●Other Precautions
• When mounting more than two Relays
on a PCB, keep the gap as shown in
the following figure.
• This Relay is suitable for power load
switching of motors, transformers,
solenoids, lamps, heaters, etc. Do not
use the G4W to switch micro loads
less than 100 mA, such as in signal
applications.
• No specified mounting direction.
• Not compatible with sockets.
3 mm
min.
3 mm min.
• There is the current-carrying metal
part on the coil terminal.
Do not mount to the PCB with
patterned metal surface.
G
4
W
㧭
Detail of part
The same
current-
carrying
metal part
with the
coil
0.2
1
5
7
terminal
㧭
10.16 15.24
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J039-E1-12
0316(0207)(O)
4
相关型号:
G4W-1112T-US-TV5-100VDC
Power/Signal Relay, SPST, Momentary, 0.008A (Coil), 100VDC (Coil), 800mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON
G4W-1112T-US-TV5-12VDC
Power/Signal Relay, SPST, Momentary, 0.067A (Coil), 12VDC (Coil), 800mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON
G4W-1112T-US-TV5-24VDC
Power/Signal Relay, SPST, Momentary, 0.033A (Coil), 24VDC (Coil), 800mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON
G4W-1112T-US-TV8-12VDC
Power/Signal Relay, SPST, Momentary, 0.067A (Coil), 12VDC (Coil), 800mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON
G4W-1112T-US-TV8-Z12VDC
Power/Signal Relay, SPST, Momentary, 0.067A (Coil), 12VDC (Coil), 800mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON
G4W-22123A-US-TV5-100VDC
Power/Signal Relay, DPST, Momentary, 0.008A (Coil), 100VDC (Coil), 800mW (Coil), 10A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON
G4W-22123A-US-TV5-24VDC
Power/Signal Relay, DPST, Momentary, 0.033A (Coil), 24VDC (Coil), 800mW (Coil), 10A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON
G4W-22123A-US-TV8-100VDC
Power/Signal Relay, DPST, Momentary, 0.008A (Coil), 100VDC (Coil), 800mW (Coil), 10A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON
G4W-22123A-US-TV8-Z12VDC
Power/Signal Relay, DPST, Momentary, 0.067A (Coil), 12VDC (Coil), 800mW (Coil), 10A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount
OMRON
©2020 ICPDF网 联系我们和版权申明