G5V-2
General-purpose, Low-cost,
Low Signal Relay
Two-pole Relays for Signal Circults
•
•
•
General-purpose DIL terminal layout.
Wide switching power of 10 μA to 2 A.
Fully-sealed type Relays standardized with bifurcated crossbar contacts. Highly
reliable in addition to its high environment resistance.
•
•
•
Conforms to FCC Part 68 (impulse withstand voltage of 1,500 V for 10 x 160 µs
between coil and contacts and between contacts of the same polarity).
High dielectric strength at 1,000 VAC between coil and contacts, and 750 VAC
between contacts of the same polarity.
UL and CSA standard approved.
RoHS Compliant
■Model Number Legend
■Application Examples
1. Number of Poles/ Contact form 2. Classification
• Telecommunication equipment
• Security equipment
G5V-@-@
—
—
2: 2-pole/DPDT (2c)
None: Standard
H1: High-sensitivity
1
2
G
5
■Ordering Information
■Characteristics
V
Minimum
packing
unit
Item
Classification
Standard
High-sensitivity
100 m max.
7 ms max.
3 ms max.
min. (at 500 VDC)
Enclosure Contact Terminal
Rated coil
voltage
Model
Contact resistance *1
Operate time
Release time
50 m
Ω
max.
Ω
rating
form
shape
2
Classification
3 VDC
5 VDC
6 VDC
Insulation resistance *2
1,000 M
Ω
Between coil and
contacts
1,000 VAC, 50/60 Hz for 1 min
Standard
G5V-2
9 VDC
12 VDC
24 VDC
48 VDC
5 VDC
12 VDC
24 VDC
48 VDC
Dielectric
strength
Between contacts
of the same polarity
Between contacts
of different polarity
Between coil and
contacts
Between contacts
of the same polarity
750 VAC, 50/60 Hz 500 VAC, 50/60 Hz for
PCB
terminals
Fully
sealed
DPDT
(2c)
25
pcs/tube
for 1 min 1 min
1,000 VAC, 50/60 Hz for 1 min
1,500 V (10 x 160
1,500 V (10 x 160
1,500 V (10 x 160
μ
μ
μ
s)
s)
s)
High-
sensitivity
G5V-2-H1
Impulse
withstand
voltage
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-2 DC3.
Between contacts
of different polarity
Rated coil voltage
However, the notation of the coil voltage on the product case as well as
on the packing will be marked as @@ VDC.
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Destruction
Malfunction
Vibration
resistance
Destruction
Malfunction
1,000 m/s2
Shock
resistance
200 m/s2
100 m/s2
15,000,000 operations min.
(at 36,000 operations/hr)
Mechanical
AC: 100,000 operations
Durability
100,000 operations
min. (at 1,800
operations/hr)
min., DC: 300,000
operations min.
Electrical
(at 1,800 operations/hr)
Failure rate (P level) (reference
value) *3
10 μA at 10 m VDC
-25°C to 65°C
(with no icing or
condensation)
-25°C to 70°C
(with no icing or
condensation)
Ambient operating temperature
Ambient operating humidity
Weight
5% to 85%
Approx. 5 g
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage
drop method.
*2. The insulation resistance was measured with a 500 VDC megohmmeter
applied to the same parts as those used for checking the dielectric strength.
*3. This value was measured at a switching frequency of 120 operations/min
and the criterion of contact resistance is 50 Ω. This value may vary
depending on the switching frequency and operating environment.
Always double-check relay suitability under actual operating conditions.
1
G5V-2
Low Signal Relay
■Ratings
●Coil
●Contacts
Must Must
operate release
voltage voltage
Classification
Standard
High-sensitivity
Resistive load
Max.
voltage
(V)
Rated
current resistance
(mA)
Coil
Power
consumption
(mW)
Load
Rated
voltage
Classification
Contact type
Contact material
Bifurcated crossbar
Ag + Au-alloy
0.5 A at 125 VAC;
2 A at 30 VDC
(V)
(V)
(Ω)
% of rated voltage
0.5 A at 125 VAC;
1 A at 24 VDC
Rated load
3 VDC 166.7
5 VDC 100
6 VDC 83.3
18
50
72
162
288
Rated carry current
Max. switching voltage
Max. switching current
2 A
125 VAC, 125 VDC
Approx. 500
75%
5%
120%
Standard 9 VDC 55.6
12 VDC 41.7
2 A
1 A
max.
min. (at 23°C)
24 VDC 20.8 1,152
48 VDC 12
5 VDC 30
12 VDC 12.5
4,000
166.7
960
Approx. 580
Approx. 150
Approx. 200
Approx. 300
180%
(at 23°C)
High-
sensitivity
75%
max.
5%
min.
24 VDC
8.33 2,880
150%
(at 23°C)
48 VDC
6.25 7,680
Note 1. The rated current and coil resistance are measured at a coil
temperature of 23°C with a tolerance of ±10%.
2.Operating characteristics are measured at a coil temperature of 23°C.
3.The maximum voltage is the highest voltage that can be imposed on the
relay coil.
■Engineering Data
G
5
●Maximum Switching Capacity
Standard/G5V-2
●Durability
Standard/G5V-2
High-sensitivity/G5V-2-H1
High-sensitivity/G5V-2-H1
V
5
100
5
100
2
24 VDC resistive load
50
3
50
30 VDC resistive load
2
1
AC resistive load
30
10
30
AC resistive load
1
125 VAC resistive load
10
0.7
0.5
0.5
DC resistive load
5
3
125 VAC resistive load
5
3
DC resistive load
0.3
0.2
0.1
0.1
1
0
1
0
10
30
50
100
300 500
1
2
3
0
10
30
50 70
125 300
500
0.5
1
1.5
Switching voltage (V)
Switching current (A)
Switching voltage (V)
Switching current (A)
●Ambient Temperature vs. Maximum Coil Voltage
Standard/G5V-2
High-sensitivity/G5V-2-H1
160
200
3 to 24 VDC
180
140
120
100
3 to 24 VDC
160
140
120
100
80
48 VDC
48 VDC
80
60
0
20
40
60
80
100
120
0
20
40
60
80
Ambient temperature (°C)
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying range
of operating power voltage, not a continuous voltage.
●Ambient Temperature vs. Must Operate or Must Release
Voltage
●Shock Malfunction
Standard/G5V-2
High-sensitivity/G5V-2-H1
Standard/G5V-2
High-sensitivity/G5V-2-H1
100
100
Y
Y
1,000
1,000
Sample: G5V-2
Number of Relays: 10 pcs
Sample: G5V-2-H1
Number of Relays: 10 pcs
max.
X
min.
800
800
600
max.
80
60
40
80
X
600
min.
X
X
Z
Z
1,000
1,000
1,000
1,000
400
400
200
200
200
60
200
400
600
800
max.
X
40
De-
energized
De-
energized
400
min.
max.
1,000
X'
1,000
X'
1,000
Z'
1,000
Z'
X
600
min.
800
20
0
20
0
Shock direction
Shock direction
X
X
X'
Energized
Unit: m/s2
Sample: G5V-2 12 VDC
Number of Relays: 10 pcs
Energized
X'
1,000
Y'
1,000
Y'
Must operate voltage
Must release voltage
Must operate voltage
Must release voltage
Y
Y
Z
Z
Unit: m/s2
Sample: G5V-2-H1 12 VDC
Number of Relays: 10 pcs
-60 -40 -20
0
20
40
60
80 100 120
-60 -40 -20
0
20
40
60
80 100 120
Z'
Z'
Y'
Y'
Ambient temperature (°C)
Ambient temperature (°C)
Conditions: Shock is applied in ±±, ±ꢀ, and ±ꢁ directions three times each with
and without energizing the Relays to check the number of contact
malfunctions.
2
G5V-2
●Dial Pulse Test
Low Signal Relay
(with Must Operate and
Must Release Voltage) *1
Standard/G5V-2
●Dial Pulse Test
(Contact Resistance) *1
●Contact Reliability Test *1, *2
Standard/G5V-2
High-sensitivity/G5V-2-H1
100
1,000
1,000
1,000
Sample: G5V-2
Number of Relays: 10 pcs
Test conditions: 10 μA resistive load at 10 mVDC
Switching frequency: 7,200 operations/h
Sample: G5V-2-H1
Number of Relays: 10 pcs
Test conditions: 10 μA resistive load at 10 mVDC
Switching frequency: 7,200 operations/h
Sample: G5V-2
Number of Relays: 10 pcs
Test conditions: Contact load WJ-926
Switching frequency: 1,800 operations/h
Sample: G5V-2
NO contact
Number of Relays: 10 pcs
Test conditions: Contact
load WJ-926
Switching frequency:
1,800 operations/h
max.
NC contact
500
300
500
500
300
80
60
40
20
300
Must operate voltage
NO contact
max.
NO contact
NC contact
max.
min.
max.
max.
NC contact
100
100
100
max.
max.
50
30
50
50
30
min.
min.
min.
min.
min.
Must release voltage
30
min.
max.
min.
10
0
10
10
0
0.3 0.5
1
3
5
10
30 50 100 300
0.3 0.5
1
3
5
10
30 50 100 300
0
5
10
50 100
500 1,000
0
5
10
50 100
5001,000
Operating frequency (×104 operations)
Operating frequency (×103 operations)
Operating frequency (×103 operations)
Operating frequency (×104 operations)
*1. The tests were conducted at an ambient temperature of 23°C.
*2. The contact resistance data are periodically measured reference values
and are not values from each monitoring operation. Contact resistance
values will vary according to the switching frequency and operating
environment, so be sure to check operation under the actual operating
conditions before use.
●High-frequency Characteristics
• Measurement Conditions
G5V-2
HR 8502A
Transmission
reflection
HR 8502A
Network
analyzer
RF
R
A
HP
8501A
G
5
test-set
50Ω
Storage
normalizer
Terminator
B
V
Note: The high-frequency characteristics data were measured using a dedicated circuit board and
actual values will vary depending on the usage conditions. Check the characteristics of the actual
equipment being used.
2
Terminals which were not being measured were terminated with 50 Ω.
Measuring impedance: 50 Ω
●High-frequency Characteristics
●High-frequency Characteristics
●High-frequency Characteristics
(Isolation) *1, *2
(Insertion Loss) *1, *2
(Return Loss, V.SWR) *1, *2
(Average value (initial))
(Average value (initial))
(Average value (initial))
0
0
0
1.5
1.4
Sample: G5V-2
Number of Relays: 5 pcs
Sample: G5V-2
Number of Relays: 10 pcs
20
20
0.05
0.1
Between c-b
V.SWR
Between c-b
Between b-c
40
1.3
1.2
40
60
Between c-a
60
Between a-b
Return loss
Between c-a
0.15
1.1
1.0
80
80
Sample: G5V-2
Number of Relays: 5 pcs
0.2
100
100
0.5
1
3
5
10
30 50 100
300 500
0.5
1
3
5
10
30 50 100
0.5
1
3
5
10
30 50 100
300 500
Frequency (MHz)
Frequency (MHz)
Frequency (MHz)
●Must Operate and Must
●Distribution of Bounce
●Must Operate and Must
●Distribution of Bounce
Release Time Distribution *1 Time *1
Standard/G5V-2
Release Time Distribution *1 Time *1
High-sensitivity/G5V-2-H1
100
40
60
80
Sample: G5V-2 12 VDC
Number of Relays: 50 pcs
Sample: G5V-2
12 VDC
Number of
Sample: G5V-2-H1
Number of Relays: 50 pcs
Sample:
Must operate time
Must release time
Operating bounce time
Release bounce time
Must operate time
Must release time
Operating bounce time
Release bounce time
G5V-2-H1
Number of
Relays: 50 pcs
Relays: 50 pcs
80
30
60
40
60
40
20
20
10
40
20
20
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6
Time (ms)
Time (ms)
Time (ms)
Time (ms)
*1. The tests were conducted at an ambient temperature of 23°C.
*2. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics, including endurance, in the actual machine
before use.
3
G5V-2
Low Signal Relay
■Dimensions
G5V-2
PCB Mounting Holes (Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
Tolerance: ±0.1 mm
10.1max.
(9.9)*
20.5max.
(20.3)*
2.54
Eight, 1dia. holes
(1.2)
7.62
(1.2)
1
8
11.5max.
0.5 (11.4)*
2.54
4
6
11
16
13
9
(No coil polarity)
0.4
0.3
7.62 5.08 5.08
3.5
7.62
(1.3)
(1.3)
0.5
* Average value
Orientation marks are indicated as follows:
Note: Each value has a tolerance of ±0.3 mm.
■Approved Standards
■Precautions
• Please refer to “PCB Relays Common Precautions” for correct use.
UL recognized:
(File No. E41515)
CSA certified: (File No. LR31928)
Correct Use
• Long-term Continuously ON Contacts
Contact ratings
Number of
test
operations
Contact Coil
form ratings
Model
G5V-2
G5V-2
G5V-2-H1
Using the Relay in a circuit where the Relay will be ON
continuously for long periods (without switching) can lead to
unstable contacts because the heat generated by the coil itself
will affect the insulation, causing a film to develop on the contact
surfaces. Be sure to use a fail-safe circuit design that provides
protection against contact failure or coil burnout.
2 A, 30 VDC at 40°C
0.6 A, 110 VDC at 40°C 0.2 A, 110 VDC at 40°C 6,000
0.6 A, 125 VAC at 40°C 0.5 A, 125 VAC at 40°C
2 A, 24 VDC at 40°C
DPDT 3 to 48
(2c)
VDC
G
5
V
2
• Relay Handling
When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep
the solvent temperature to less than 40°C. Do not put the Relay
in a cold cleaning bath immediately after soldering.
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K046-E1-06
0316(0207)(O)
4
相关型号:
G5V-2-DC3
Power/Signal Relay, DPDT, Momentary, 0.167A (Coil), 3VDC (Coil), 500mW (Coil), 2A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G5V-2-DC48
Power/Signal Relay, DPDT, Momentary, 0.012A (Coil), 48VDC (Coil), 580mW (Coil), 2A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G5V-2-DC5
Power/Signal Relay, DPDT, Momentary, 0.1A (Coil), 5VDC (Coil), 500mW (Coil), 2A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G5V-2-DC6
Power/Signal Relay, DPDT, Momentary, 0.083A (Coil), 6VDC (Coil), 500mW (Coil), 2A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G5V-2-H-DC12
Power/Signal Relay, DPDT, Momentary, 0.03A (Coil), 12VDC (Coil), 360mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G5V-2-H-DC24
Power/Signal Relay, DPDT, Momentary, 0.015A (Coil), 24VDC (Coil), 360mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G5V-2-H-DC5
Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.072A (Coil), 5VDC (Coil), 360mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G5V-2-H-DC6
Power/Signal Relay, DPDT, Momentary, 0.06A (Coil), 6VDC (Coil), 360mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明