G6B-1114P-FD-USDC24 [OMRON]
Power/Signal Relay,;型号: | G6B-1114P-FD-USDC24 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay, 继电器 |
文件: | 总10页 (文件大小:2047K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
G6B
PCB Power Relay
High Capacity and High
DielectricStrengthMiniature
Relay with Fully Sealed
Construction in 5 A (8 A)
SPST-NO(1a),
SPST-NO+SPST-NC(1a1b),
DPST-NO(2a),
DPST-NC(2b) Types
• High sensitive with operating power of 98 mW.
(G6B-1114P-US and G6B-1174P-US models)
• High insulation with dielectric strength of 3,000VAC
between coil and contacts (impulse withstand voltage of 6 kV).
• Stick packing models are provided in consideration of compatibility to the automatic production line.
• Standard model conforms to UL/CSA standards. Other SEV approved models are also available.
• AgSnIn contacts suitable for loads that generate surge voltage (inductive load, capacity load, etc.) available. (-FD type)
• Ultrasonic cleanable models available. (-U type)
G
6
B
• Operation indicator & built-in surge absorption diode available. (-ND type)
• 2-Pole type available.
■Application Examples
RoHS Compliant
• Ideal for output applications of control equipments
■Model Number Legend
G6B@-@@@@@-@--@-@-@-@
1
2
3 4 5
6
7
8
9 10
1. Relay Function
3. Classification
1: Standard
7. Operation Indicator Diode
Availability
None: Single-side stable
U
K
: Single-winding latching
(G6B@-1114 models only)
: Double-winding latching
(G6B@-1114 models only)
7: High-capacity
None: Standard
ND : Operation indicator & coil surge
absorption diode
4. Enclosure rating
4: Fully sealed
(for -1177 type only)
7: Flux protection
2. Contact Form
21: SPST-NO + SPST-NC
22: DPST-NO
8. Approved Standards
5. Terminal Shape
US: UL/CSA
P: PCB terminals
Socket mounting terminals
9. Washability
20: DPST-NC
None: Standard
6. Contact material
11: SPST-NO
U
: For ultrasonically cleanable
None: Standard (Ag-alloy (Cd free))
FD : AgSnIn contact
10.Mounting
(Suitable for DC inductive load with
high inrush current)
None: Mounted directly to PCB
P6B : Mounted to Socket
1
G6B
■Ordering Information
PCB Power Relay
●Standard Models (UL, CSA certified)
Contact material
Standard (Ag-alloy (Cd free))
AgSnIn contact
Number
of poles
Minimum
packing unit
Relay Function
Contact form
Model
Rated coil voltage
Model
Rated coil voltage
SPST-NO (1a)
(Standard)
100
pcs/tray
G6B-1114P-US
5, 6, 12, 24 VDC G6B-1114P-FD-US
5, 6, 12, 24 VDC
Single-side stable
SPST-NO (1a)
(High-capacity)
20
pcs/tube
G6B-1174P-US
5, 6, 12, 24 VDC G6B-1174P-FD-US
5, 6, 12, 24 VDC
Single-winding
latching
SPST-NO (1a)
(Standard)
G6BU-1114P-US
G6BK-1114P-US
5, 6, 12, 24 VDC G6BU-1114P-FD-US
5, 6, 12, 24 VDC G6BK-1114P-FD-US
5, 12, 24 VDC
1-pole
100
pcs/tray
Double-winding
latching
SPST-NO (1a)
(Standard)
5, 6, 12, 24 VDC
SPST-NO (1a)
(Built-in high-capacity
operation indicator &
diode)
20
pcs/tube
Single-side stable
G6B-1177P-ND-US
5, 12, 24 VDC
G6B-1177P-FD-ND-US 5, 12, 24 VDC
SPST-NO (1a)+
SPST-NC (1b) (Standard)
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
5, 6, 12, 24 VDC G6B-2114P-FD-US
5, 6, 12, 24 VDC G6B-2214P-FD-US
5, 6, 12, 24 VDC G6B-2014P-FD-US
5, 6, 12, 24 VDC
5, 6, 12, 24 VDC
5, 6, 12, 24 VDC
DPST-NO (2a)
(Standard)
100
pcs/tray
2-pole Single-side stable
DPST-NC (2b)
(Standard)
Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened.
G
6
B
●Models for Ultrasonically Cleanable
Contact material
Contact form
Standard (Ag-alloy (CD free))
AgSnIn contact
Number
of poles
Minimum
packing unit
Relay Function
Model
Rated coil voltage
Model
Rated coil voltage
SPST-NO (1a)
(Standard)
Single-side stable
G6B-1114P-US-U
5, 6, 12, 24 VDC G6B-1114P-FD-US-U
6, 12, 24 VDC
Single-winding
latching
SPST-NO (1a)
(Standard)
1-pole
G6BU-1114P-US-U
G6BK-1114P-US-U
G6B-2114P-US-U
G6B-2214P-US-U
G6B-2014P-US-U
24 VDC
−
−
Double-winding
latching
SPST-NO (1a)
(Standard)
5, 6, 12, 24 VDC G6BK-1114P-FD-US-U 12, 24 VDC
100
pcs/tray
SPST-NO (1a)+
SPST-NC (1b) (Standard)
5, 12, 24 VDC
G6B-2114P-FD-US-U
5, 12, 24 VDC
5, 12, 24 VDC
5, 12, 24 VDC
DPST-NO (2a)
(Standard)
2-pole Single-side stable
5, 6, 12, 24 VDC G6B-2214P-FD-US-U
DPST-NC (2b)
(Standard)
5, 12, 24 VDC
G6B-2014P-FD-US-U
Note: When ordering, add the rated coil voltage to the model number.
Example: G6B-1114P-US DC5
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
●Connecting Sockets (Sold Separately)
Applicable relay
Model
Minimum ordering unit
G6B-1114P(-FD)-US-P6B
G6B-1174P(-FD)-US-P6B
G6B-1177P(-FD)-ND-US-P6B
G6BU-1114P-US-P6B
P6B-04P
20 pcs
G6BK-1114P-US-P6B
P6B-06P
P6B-26P
G6B-2114P-US-P6B
G6B-2214P-US-P6B
G6B-2014P-US-P6B
Removal Tool
P6B-Y1
P6B-C2
1 pcs
Hold-down Clips
Note 1. G6B-1174P-US-P6B and G6B-1177P-ND-US-P6B are rated for 8 A when mounted on a PCB. However,
when used with the P6B-04P socket models, the allowable current is derated to 5 A.
2.The P6B sockets are designed to be used with G6B-@@@@P(-FD)-US-P6B relays. Only use G6B relays
that include "-P6B" in their model numbers with the sockets. Do not use standard G6B's that omit "-P6B"
from their model numbers with the sockets.
3.The hold-down clips of the P6B-C2 model are not suitable for the G6B-1174P and G6B-1177P models
since they have different heights.
4.Products with UL/CSA certification marks will be supplied for orders of standard models.
2
G6B
■Ratings
PCB Power Relay
●Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)
Must operate Must release Max. voltage
Item
Rated current Coil resistance
Power consumption
(mW)
voltage (V)
voltage (V)
(V)
(mA)
(Ω)
Rated voltage
% of rated voltage
5 VDC
6 VDC
40
125
180
33.3
16.7
8.3
160%
(at 23°C)
70% max.
10% min.
Approx. 200
12 VDC
24 VDC
720
2,880
●Coil: 2-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)
Must operate Must release Max. voltage
Item
Rated current Coil resistance
Power consumption
(mW)
voltage (V)
voltage (V)
(V)
(mA)
(Ω)
Rated voltage
% of rated voltage
5 VDC
6 VDC
60
83.3
50
120
480
140%
(at 23°C)
80% max.
10% min.
Approx. 300
12 VDC
24 VDC
25
12.5
1,920
●Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)
Must set Must reset Max. voltage
Item
Power consumption
Rated
current
(mA)
Coil
resistance
(Ω)
voltage (V) voltage (V)
(V)
Set coil
(mW)
Reset coil
(mW)
% of rated voltage
Rated voltage
5 VDC
6 VDC
40
125
180
G
6
B
33.3
16.7
8.3
160%
(at 23°C)
70% max. 70% max.
200
200
12 VDC
24 VDC
720
2,880
●Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)
Must set voltage Must reset voltage Max. voltage
Rated current (mA)
Coil resistance (Ω)
Power consumption
Item
(V)
(V)
(V)
Set coil
(mW)
Reset coil
(mW)
Rated voltage
Set coil
Reset coil
Set coil Reset coil
% of rated voltage
5 VDC
6 VDC
56
56
89.2
128.5
515
89.2
128.5
515
46.8
23.3
11.7
46.8
23.3
11.7
130%
(at 23°C)
70% max.
70% max.
280
280
12 VDC
24 VDC
2,060
2,060
●Coil: Operation Indicator Model (Flux-resistant type. Do not wash down with water.)
Must operate Must release Max. voltage
Item
Rated current Coil resistance
Power consumption
(mW)
voltage (V)
voltage (V)
(V)
(mA)
(Ω)
Rated voltage
% of rated voltage
5 VDC
12 VDC
24 VDC
43
116
610
Approx. 200
Approx. 240
Approx. 275
130%
(at 23°C)
19.7
11.3
70% max.
10% min.
2,120
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.The operating characteristics are measured at a coil temperature of 23°C.
3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●Contacts
G6B-1114P-US
G6BU-1114P-US
G6BK-1114P-US
G6B-1114P-FD-US
G6BU-1114P-FD-US
G6BK-1114P-FD-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
G6B-1174P-US
G6B-1177P-ND-US
G6B-1174P-FD-US
G6B-1177P-FD-ND-US
Model
Load
Inductive load
= 0.4; L/R = 7 ms)
Inductive load
= 0.4; L/R = 7 ms)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
Resistive load
Resistive load
Item
(cosφ
(cos
φ
Contact type
Contact material
Single
Ag-Alloy (Cd free)
5 A (3 A) at 250 VAC
5 A (3 A) at 30 VDC
2 A (2 A) at 250 VAC
2 A (2 A) at 30 VDC
8 A (5 A) at 250 VAC
8 A (5 A) at 30 VDC
2 A (2 A) at 250 VAC
2 A (2 A) at 30 VDC
5 A (3 A) at 250 VAC 1.5 A (1.5 A) at 250 VAC
5 A (3 A) at 30 VDC 1.5 A (1.5 A) at 30 VDC
5 A (5 A)
Rated load
Rated carry current
5 A (5 A)
8 A (5 A)
Max. switching voltage
Max. switching current
380 VAC, 125 VDC
8 A (5 A)
5 A (5 A)
5 A (5 A)
Note 1. The values in the parentheses ( ) are for -FD models only.
2.Use the -FD type for inductive load and switching load which contact roughening is small.
3
G6B
■Characteristics
PCB Power Relay
G6B-2114P-US
G6B-2114P-FD-US
G6B-2214P-US
G6B-1114P-US
G6B-1114P-FD-US
G6B-1174P-US
G6B
Model
G6BU-1114P-US
G6BK-1114P-US
-1177P(-FD)-ND-US G6B-2214P-FD-US
G6B-2014P-US
G6B-1174P-FD-US
G6B-2014P-FD-US
Built-in operation
indicator & surge
absorption diode
Single-winding
latching
Double-winding
latching
Item
Classification Single-side stable
Single-side stable
Contact resistance *1
Operate (set) time
Release (reset) time
Min. set pulse width
Min. reset pulse width
Insulation resistance *2
30 mΩ max.
10 ms max.
10 ms max.
−
−
15 ms (at 23°C)
15 ms (at 23°C)
1,000 MΩ min.
−
−
2,000 VAC,
50/60 Hz for 1 min
Between coil and contacts
3,000 VAC, 50/60 Hz for 1 min
3,000 VAC, 50/60 Hz for 1 min
Between contacts of the same
polarity
Between contacts of different
polarity
1,000 VAC, 50/60 Hz for 1 min
Dielectric strength
2,000 VAC,
50/60 Hz for 1 min
−
250 VAC,
50/60 Hz for 1 min
Between set and reset coils
−
−
Impulse withstand voltage (between coil and contacts)
6 kV 1.2 × 50 μs
4.5 kV 1.2 × 50 μs
6 kV 1.2 × 50 μs
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s2
Vibration
resistance
Shock resistance
Durability
G
6
B
100 m/s2
300 m/s2
100 m/s2
50,000,000 operations min. (at 18,000 operations/hr)
100,000 operation min. (at 1,800 operations/hr under rated load)
10 mA at 5 VDC
Failure rate (P level) (reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
-25°C to 70°C (with no icing or condensation)
5% to 85%
Approx. 3.5 to 4.6 g
Approx. 3.5 g
Approx. 3.7 g
Approx. 5.4 g
Approx. 4.5 g
Note 1. The values here are initial values.
2.The G6B-1177P(-FD)-ND model is flux-resistant. Do not wash it down with water.
*1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.
*2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was
measured.(Except the location between set/reset coil)
*3. This value was measured at a switching frequency of 120 operations/min.
4
G6B
■Engineering Data
PCB Power Relay
●Maximum Switching Current
G6B-1114P-US
G6B-1174P-FD-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
G6B-1174P-US
40
100
100
50
30
50
30
20
10
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
AC inductive load
(cosφ = 0.4)
AC resistive load
AC resistive load
5
10
8
10
AC resistive
load
3
2
5
5
3
2
1.5
1
AC
inductive
load
3
2
DC inductive load
(L/R = 7 ms)
cosφ = 0.4
1
DC resistive load
AC
AC
inductive
load
1
resistive
load
DC resistive load
0.5
DC resistive load
0.5
0.3
0.5
0.3
0.3
0.2
DC inductive load
DC inductive load
(L/R = 7 ms)
0.1
0.1
0.1
0
3
5
10 20 30
100
300 500
0
3
5
10
30 50 100
380 1,000
0
3
5
10
30 50 100
300 500 1,000
Switching voltage (V)
Switching voltage (V)
Switching voltage (V)
●Ambient Temperature vs.
●Durability
Maximum Coil Voltage
G6B-1114P-US
G6B-1174P-US
G6B-1174P-FD-US
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
G6B-1114P-US
G6B-1174P-US
G6B-1174P-FD-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
1,000
1,000
200
G
6
B
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
250 VAC/30 VDC inductive load
(cosφ = 0.4, L/R = 7 ms)
G6B-1114P-US
250 VAC/30 VDC resistive load
500
300
500
180
G6B-1114P-US
300
100
G6B-1174P-US
G6B-1174P-FD-US
250 VAC/30 VDC resistive load
G6B-1174P-FD-US
160
100
G6B-1174P-US
250 VAC/30 VDC
resistive load
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
140
130
120
110
100
50
30
50
30
250 VAC/30 VDC resistive load
10
10
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
Higher
capacity
G6B-1114P-US
G6B-1174P-FD-US
G6B-1174P-US
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
250 VAC resistive load
5
3
5
3
80
60
250 VAC/30 VDC inductive load
(cosφ = 0.4, L/R = 7 ms)
1
1
0
20 23 30
40
50
60
70
80 90
0
1
2
3
4
5
6
7
8
9
10
0
1 1.5 2
3
4
5
6
7
8
9
10
Ambient temperature (°C)
Switching current (A)
Switching current (A)
Note: The maximum coil voltage refers to the
maxi-mum value in a varying range of
operating power voltage, not a continuous
voltage.
●Ambient Temperature vs. Must
Operate and Must Release Voltage
G6B-1114P-US
●Mutual Magnetic Interference
G6B-1114P-US
G6B-1114P-US
Must operate voltage
Must release voltage
Must operate voltage
Must release voltage
100
Sample:
G6B-1114P-US
Number of Relays: 5 pcs
Must operate voltage
Must release voltage
Initial stage
Test
Initial stage
Test
2.54 mm
+1.0
+1.0
max.
X
80
60
40
20
+0.5
+0.5
min.
2.54 mm
0
0
Sample
De-energized
−0.5
−1.0
−0.5
Sample
Average value
Average value
−1.0
max.
De-energized
Initial stage
Initial stage
Test
Test
Sample
X
min.
+1.0
+1.0
+0.5
+0.5
Sample
0
0
Energized
−0.5
−1.0
−0.5
−1.0
0
−40
−20
0
20
40
60
80
Average value
Average value
Energized
Ambient temperature (°C)
5
G6B
●Shock Malfunction
PCB Power Relay
Y
Y
Y
Reset
1ꢀ000
1,000
Energized
Energized
600
Set
300
X
400
Z
X
1,000
X
1ꢀ000
Z
Z
1,000
1ꢀ000
300
700
100
100
200
200
400
X'
1ꢀ000
X'
1,000
Z'
1ꢀ000
Z'
1,000
X'
300
Z'
300
Unit: m/s2
1,000
Y'
1ꢀ000
Y'
Unit: m/s2
Unit: m/s2
Y'
Sample: G6B-1174P-US
G6B-1174P-FD-US
Test Conditions: Shock is applied in X, Y,
and Z directions three times each ꢀith ꢀithout
Sample: G6B-1114P-US
Number of Relays: 12 pcs
Test Conditions: Shock is applied in Xꢀ Yꢀ
and Z directions three times each ꢁith ꢁithout
Sample: G6BK-1114P-US
Number of Relays: 12 pcs
Test Conditions: The value at ꢁhich
malfunction occurred ꢁas measured after
applying shock to the
energizing the Relays
to check the number of
malfunctions.
energizing the Relays
Shock direction
Shock direction
Shock direction
X
X'
X
X'
to check the number of
malfunctions.
X
X'
test piece 3 times each
in 6 directions along 3
Y
Y
Y
Z
Z'
Z
Z
Requirement: None
Requirement: None
axes.
Z'
malfuction 100 m/s2
malfuction 100 m/s2
Z'
Standard value:
300 m/s2
Y'
Y'
Y'
(Coil)
(Coil)
(Coil)
●Hot Start
40
40
40
30
Sample: G6B-2114P-US
G6B-2214P-US
Sample: G6B-1114P-US
G6B-1174P-FD-US
Number of Relays: 10 pcs
Test: the variation of operating voltage is measured
based on cold start at 23°Cꢀ during ꢁhich rated
voltage is applied to the coil ꢁith rated
contact current (5A)ꢀ and left for 1
hour each under different
ambient
temperatures.
Sample: G6B-1174P-US
Test: the variation of operating voltage is measured
based on cold start at 23°C, during ꢀhich rated
voltage is applied to the coil ꢀith rated contact
current (8A), and left for 1 hour
G6B-2014P-US
G
6
B
30
20
10
0
30
Test: the variation of operating voltage is
measured based on coil cold start at 23°C, during
ꢀhich rated voltage is applied to the coil ꢀith rated
contact current (5A), and left
each under different ambient
20 temperatures.
20
10
0
for 1 hour each under different
ambient temperatures.
120% applied
110% applied
120% applied
110% applied
100% applied
10
0
120% applied
110% applied
100% applied
100% applied
−10
−10
−20
−10
−20
−20
−50
−40 −20
0
20
40
60
80 100
−50
−40 −20
0
20
40
60
80 100
−50
−40 −20
0
20
40
60
80 100
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
■Dimensions
1-pole Single-side Stable Models
G6B-1114P(-FD)-US
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.54
Four, 1.1-dia. holes
10 max.
(9.8)*
2.54
10 max.
(9.8)* 0.3
(1.2)
1
3
4
6
3.5
0.85 0.9
<0.9> <1.0>
Note: Check carefully
the coil polarity of the
Relay.
0.9<1.0>
0.5<0.4>
20 max.
(19.9)*
10.16
7.62
0.5
(1.1)
* Average value
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
Note: Orientation marks are indicated as follows:
1-pole Single-side Stable Models
G6B-1174P(-FD)-US
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
2.54
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Four, 1.1-dia. holes
10 max.
(9.9)*
2.54
(1.2)
12.5 max.
(12.45)* 0.65
1
6
3
4
3.5
0.9
0.85
<1.0>
<0.9>
Note: Check carefully
the coil polarity of the
Relay.
0.9<1.0>
0.5<0.4>
20.2 max.
(20.0)*
10.16
7.62
0.45
(1.2)
* Average value
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
Note: Orientation marks are indicated as follows:
6
G6B
PCB Power Relay
1-pole Single-winding Latching Model
G6BU-1114P-US
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
2.54
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Four, 1.1-dia. holes
10 max.
(9.8)*
2.54
(1.2)
10 max.
(9.8)* 0.3
1
6
3
4
S
R
3.5
0.85 0.9
Note: Check carefully
the coil polarity of the
Relay.
<0.9> <1.0>
0.5<0.4>
* Average value
0.9<1.0>
20 max.
(19.9)*
10.16
7.62
0.5
(1.1)
S: Set coil
R: Reset coil
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
Note: Orientation marks are indicated as follows:
1-pole Double-winding Latching Model
G6BK-1114P-US
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
2.54
Six, 1.1-dia. holes
10 max.
(9.8)*
2.54
(1.2)
1
6
2
5
10 max.
(9.8)* 0.3
3
R
4
S
3.5
0.85
<0.9>
0.9
Note: Check carefully
the coil polarity of the
Relay.
<1.0>
0.85
0.9<1.0>
0.5<0.4>
* Average value
<0.9>
20 max.
(19.9)*
2.54
7.62
7.62
0.5
G
6
B
(1.1)
S: Set coil
R: Reset coil
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
Note: Orientation marks are indicated as follows:
1-pole Single-side stable Models SPST-NO (1a) (Built-in high capacity operation
indicator & surge absorption diode)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
20.2 max.
(20)*
0.45
G6B-1177P(-FD)-ND-US
3.7
1.7
Four, 1.1-dia. holes
2.54
10 max.
(9.9)*
1
3
4
2.54
LED
1.6
0.3
7.62
(1.2)
6
Note: Check carefully the
coil polarity of the Relay.
15 max.
(14.8)*
(1.11)
10.16
7.62
0.65
Note: The G6B-1177P-ND-US model has a flux-resistant
construction. Do not wash it down with water. Pay
attention to the polarity of the coil since the LED and
surge absorption diode are built-in.
3.5
0.85 0.9
<0.9> <1.0>
0.9<1.0>
0.5<0.4>
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
10.16
7.62
7.62
* Average value
2-poles Single-side stable Models (SPST-NO (1a) + SPST-NC (1b),
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
20 max.
DPST-NC (2c), SPST-NO(1a))
(19.9)*
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
11 max.
(10.9)*
Six, 1.1-dia. holes
2.54
G6B-2114P-US
1
3
4
2.54
7.62
(1.7)
8
6
5
11 max.
(10.9)*
(1.11)
10.16
7.62
G6B-2014P-US
3.5
1
3
4
0.9<0.8>
0.4<0.3>
10.16
7.62
7.62
8
6
5
* Average value
G6B-2214P-US
Dimensions in pointed brackets < > are
for the Relay mounted to Socket.
1
3
4
8
6
5
Note: Check carefully
the coil polarity of the
Relay.
7
G6B
■Connecting Sockets Dimensions
PCB Power Relay
Socket for 1-pole Single-winding Latching Model and
Single-side Stable Model
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
23.2 max.
P6B-04P
(23)*
Four, 1.1-dia. holes
10 max.
(9.9)*
2.54
3.1
2.54
2.54
2.54
(1.2)
10.1 max.
(10)*
7
(2.71)
10.16
7.62
3.5
0.8
0.4
10.16
7.62
7.62
* Average value
Socket for 1-pole Double-winding Latching Model
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
P6B-06P
23.2 max.
(23)*
10 max.
(9.9)*
3.1
Six, 1.1-dia. holes
2.54
G
6
B
(1.2)
10.1 max.
(10)*
7
3.5
(2.71)
7.62
7.62
0.8
2.54
0.4
2.54
7.62
7.62
7.62
* Average value
Socket for Double-pole Single-side Stable
P6B-26P
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
23.2 max.
(23)*
11 max.
(10.8)*
3.1
Six, 1.1-dia. holes
2.54
10.1 max.
(10)*
(1.6)
7
3.5
(2.61)
10.16
7.62
0.8
0.4
10.16
7.62
7.62
* Average value
■Removal Tool
■Hold-down Clips
■Related Products
P6B-Y1
P6B-C2
The G6B-4 Terminal Relay series with
4-point output is also available.
For details, contact your OMRON sales
representative.
8
G6B
■Approved Standards
PCB Power Relay
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL Recognized:
(File No. E41643)
Contact
Coil
ratings
Number of test
operations
Model
Contact ratings
form
1
5 A, 250 VAC (General Use) at 80°C
5A, 30 VDC at 80°C
6,000
1,000
G6B-1114P-US
G6B-1114P-FD-US
3 to 24
VDC
1/8HP, 250 VAC at 80°C
1/6HP, 250 VAC at 80°C
8 A, 250 VAC (General Use) at 80°C
8 A, 30 VDC at 80°C
G6B-1174P-US
G6B-1174P-FD-US
3 to 24
VDC
1
2
6,000
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
5 A, 250 VAC (General Use) at 40°C
3 to 24
VDC
5 A, 30 VDC at 40°C
CSA Certified:
(File No. LR31928)
Contact
form
Coil
ratings
Number of test
operations
Model
Contact ratings
5 A, 250 VAC (General Use) at 80°C
5A, 30 VDC at 80°C
6,000
G6B-1114P-US
G6B-1114P-FD-US
3 to 24
VDC
1
1/6HP, 250 VAC at 80°C
1,000
6,000
G
6
B
360WT, 120 VAC at tungsten 80°C
8 A, 250 VAC (General Use) at 80°C
8 A, 30 VDC at 80°C
G6B-1174P-US
G6B-1174P-FD-US
3 to 24
VDC
1
2
6,000
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
5 A, 250 VAC (General Use) at 40°C
3 to 24
VDC
5 A, 30 VDC at 40°C
EN/IEC, TÜV Certified:
(Registration No. R50158246)
Coil
Contact
Number of test
operations
Model
Contact ratings
form
ratings
5 A, 250 VAC (cosφ = 1) at 70°C
2 A, 250 VAC (cosφ = 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
8 A, 250 VAC (cosφ = 1) at 70°C
2 A, 250 VAC (cosφ = 0.4) at 70°C
8 A, 30 VDC (L/R = 0 ms) at 70°C
5 A, 250 VAC (cosφ = 1) at 70°C
1.5 A, 250 VAC (cosφ = 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
5, 6 12,
24 VDC
G6B-1114P-US
1
5, 6 12,
24 VDC
G6B-1174P-US
1
2
20,000
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
5, 6 12,
24 VDC
9
G6B
■Precautions
PCB Power Relay
●Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Mounting
●Inhibit Circuit of the
●Other precautions
G6B-1177P(-FD)-ND-US Model
• When installing more than two Relays
side by side on a PCB, keep the gaps
as shown below.
• The P6B model has a flux-resistant
construction. Do not wash it down with
water.
• Do not use under conditions in which a
surge is included in the power supply,
such as when an inductive load is
It may cause a malfunction if heat is
not dissipated smoothly from the
Relay.
• Perform wiring of No.1 and No. 2 of
the X terminal as COM for double-
winding latching as shown below. The
operation stability improves by doing
this.
connected in parallel to the coil. Doing
so will cause damage to the installed
(or built-in) coil surge absorbing diode.
Pitch:
2.54 mm × 2 min.
betꢀeen terminals
Coil surge
absorption
diode
Inductive
load
G6B
Coil
L
6
5
R
2
Pitch: 2.54 mm × 2 min.
betꢀeen terminals
S
• No specified mounting direction.
1
●Using SPDT contact of the
SPST-NO+SPST-NC Relay
●Mounting Height of Sockets and
COM
Precautions
• Check carefully the coil polarity (+ and -)
of the Relay G6B-1177P(-FD)-ND-US.
Do not reverse the polarity when
connecting. Otherwise the built-in coil
surge absorption diode may be
damaged.
• Do not construct a circuit so that
overcurrent and burning occur if the
NO, NC and SPDT contacts are
short-circuited with the
G
6
B
* 19.5 mm max. for
*17 mm max.
G6B-1174P-FD-US,
G6B-1174P-US models
7 mm max.
and 22 mm max. for
G6B-1177P-FD-ND-US,
G6B-1177P-ND-US models.
SPST-NO+SPST-NC Relay.Arcing
may generate short-circuiting between
contacts if there is short-circuiting
because of conversion to the MBB
contact caused by asynchronous
operation of the NO and NC contacts,
the interval between the NO and NC
contacts is small, or a large current is
left open.
• Hold-down clips (for mounting and
removal) are also available.(For P6B-
C2 model) However, it is not suitable
for G6B-1174P and G6B-1177P
models.
• This Relay is a Power Relay which is
suitable for power load switching. Do
not use the G6B for signal purposes
such as micro load switching under 10
mA.
• Removal tool is also available.
(For P6B-Y1 model) However, it is not
suitable for G6B-1177P model.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K021-E1-14
0316(0207)(O)
10
相关型号:
G6B-1114P-US-5VDC
Power/Signal Relay, 1 Form A, SPST, Momentary, 0.04A (Coil), 5VDC (Coil), 200mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6B-1114P-US-6VDC
Power/Signal Relay, SPST, Momentary, 0.033A (Coil), 6VDC (Coil), 200mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6B-1114P-US-DC12
Power/Signal Relay, 1 Form A, SPST, Momentary, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6B-1114P-US-DC6
Power/Signal Relay, SPST, Momentary, 0.033A (Coil), 6VDC (Coil), 200mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明