G6C
PCB Power Relay
Miniature High Capacity Relays
with SPST-NO 10A and SPST-NO +
SPST-NC 8A
• SPST-NO 10A and SPST-NO + SPST-NC 8A for power switching and
output that satisfy the needs for space-saving.
• Small High-capacity Relays Compact: 20 × 15 × 10 mm (L × W × H).
• Low power consumption: 200 mW.
• Ultrasonically cleanable models is available.
• Exclusive P6C model for sockets is now available.
RoHS Compliant
■Model Number Legend
G6C-@-@@@@@-@-@-@-@
■Application Examples
Ideal for output applications of control
equipments
1
2
3 4 5
6
7
8
9
G
6
C
1. Relay Function
6. Contact Material
None: Single-side stable
None: Standard (Ag-alloy (Cd free))
FD : AgSnIn Contacts
U
K
: Single-winding latching
: Double-winding latching
(Suitable for DC inductive load
with high inrush current)
2. Contact Form
11: SPST-NO (1a)
7. Approved Standards
21: SPST-NO (1a) + SPST-NC (1b)
US: UL/CSA
3. Contact Type
8. Washability
1: Single
None: Standard model
(not compatible with ultrasonically
cleanable models)
4. Enclosure rating
4: Fully sealed
U
: For ultrasonically cleanable
7: Flux protection
9. Mounting
5. Terminal Shape
P: PCB terminals
None: Mounted directly to PCB
P6C : Mounted to Socket
Socket mounting Terminals
1
G6C
PCB Power Relay
■Ordering Information
●Standard Models (UL, CSA certified)
Relay
Single-side stable
Function
Single-winding latching
Double-winding latching
Minimun
packing unit
Enclosure
rating
Contact
form
Rated coil
voltage
Rated coil
Rated coil
voltage
Model
Model
Model
voltage
3 VDC
5 VDC
−
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
SPST-NO
(1a)
G6C-1117P-US
G6CU-1117P-US
G6CK-1117P-US
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
100 pcs/
tray
Flux protection
SPST-NO
(1a) +
SPST-NC
(1b)
G6C-2117P-US
G6C-1114P-US
G6C-2114P-US
G6CU-2117P-US
G6CU-1114P-US
G6CU-2114P-US
G6CK-2117P-US
G6CK-1114P-US
G6CK-2114P-US
SPST-NO
(1a)
100 pcs/
tray
Fully sealed
SPST-NO
(1a) +
SPST-NC
(1b)
G
6
C
Note1.When ordering, add the rated coil voltage to the model number.
Example: G6C-1117P-US DC3
G6C-1117P
-US
G6C-2114P
-US
CONTACT:
TV-5
10A 250VAC
10A 30VDC
COIL:24VDC
CONTACT:
TV-5
8A 250VAC
8A 30VDC
COIL:24VDC
Rated coil voltage
24VDC
MADE IN
JAPAN
24VDC
MADE IN
JAPAN
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Note2.Products with UL/CSA certification marks will be supplied for orders of standard models (-US models).
●Ultrasonically Cleanable Models (UL, CSA certified)
Relay
Function
Single-side stable
Single-winding latching
Double-winding latching
Minimun
packing unit
Enclosure
rating
Contact
form
Rated coil
Rated coil
voltage
Rated coil
voltage
Model
Model
Model
voltage
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
−
5 VDC
−
12 VDC
24 VDC
−
−
5 VDC
−
12 VDC
24 VDC
−
5 VDC
−
12 VDC
−
5 VDC
SPST-NO
(1a)
G6C-1114P-US-U
G6CU-1114P-US
−
G6CK-1114P-US
12 VDC
−
−
−
−
−
−
100 pcs/
tray
Fully sealed
SPST-NO
(1a) +
SPST-NC
(1b)
G6C-2114P-US-U
G6CU-2114P-US
G6CK-2114P-US
Note1.When ordering, add the rated coil voltage to the model number.
Example: G6C-1114P-US-U DC3
G6C-1117P
G6C-2114P
-US
CONTACT:
-US
CONTACT:
TV-5
8A 250VAC
8A 30VDC
COIL:24VDC
Rated coil voltage
TV-5
10A 250VAC
10A 30VDC
COIL:24VDC
24VDC
MADE IN
JAPAN
24VDC
MADE IN
JAPAN
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Note2.Products with UL/CSA certification marks will be supplied for orders of standard models (-US models).
●Connecting Sockets (Sold Separately)
Applicable relays
Model
Minimun packing unit
G6C-2114P-US-P6C
G6C-2117P-US-P6C
G6C-1114P-US-P6C
G6C-1117P-US-P6C
G6CU-2114P-US-P6C
G6CU-2117P-US-P6C
G6CU-1114P-US-P6C
G6CU-1117P-US-P6C
P6C-06P
20 pcs/tube
G6CK-2114P-US-P6C
G6CK-2117P-US-P6C
G6CK-1114P-US-P6C
G6CK-1117P-US-P6C
P6C-08P
Removal Tool
P6B-Y1
P6B-C2
1
Hold-down Clips
Note 1. Use the G6C-@@@@P-US-P6C to mount to a P6C Socket.
2. When using by combining sockets, the rated current will be 5A due to its rated switching current.
2
G6C
PCB Power Relay
■Ratings
Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)
Item
Must operate Must release
Max.
voltage
(V)
Rated
current
(mA)
Coil
resistance
(Ω)
Power
consumption
(mW)
voltage
(V)
voltage
(V)
Rated voltage
ꢀ of rated voltage
3 VDC
5 VDC
67
45
125
40
160ꢀ
(at 23°C)
6 VDC
33.3
16.7
8.3
180
70ꢀ max.
10ꢀ min.
Approx. 200
12 VDC
24 VDC
720
2,880
Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)
Item
Must set Must reset
Max.
voltage
(V)
Power consumption
Rated
current
(mA)
Coil
resistance
(Ω)
voltage
(V)
voltage
(V)
Set coil
(mW)
Reset coil
(mW)
Rated voltage
ꢀ of rated voltage
3 VDC
5 VDC
67
45
125
40
160ꢀ
(at 23°C)
6 VDC
33.3
16.7
8.3
180
70ꢀ max. 70ꢀ max.
200
200
12 VDC
24 VDC
720
2,880
Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)
Item
Rated current (mA)
Set coil Reset coil
93.5 93.5
Coil resistance (Ω)
Must set
voltage
(V)
Must reset
voltage
(V)
Max.
voltage
(V)
Power consumption
G
6
C
Set coil
(mW)
Reset coil
(mW)
Set coil Reset coil
Rated voltage
ꢀ of rated voltage
3 VDC
5 VDC
32.1
89.3
32.1
89.3
56.0
46.7
23.3
11.7
56.0
46.7
23.3
11.7
130ꢀ
(at 23°C)
6 VDC
129
129
70ꢀ max.
70ꢀ max.
280
280
12 VDC
24 VDC
514
514
2,056
2,056
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10ꢀ.
2.The operating characteristics are measured at a coil temperature of 23°C.
3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Contact
Contact Form
Rated load
SPST-NO (1a)
SPST-NO (1a) + SPST-NC (1b)
Inductive load
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
Resistive load
(cosφ = 0.4; L/R = 7 ms)
10 A (8 A) at 250 VAC
10 A (10 A) at 30 VDC
5 A (5 A) at 250 VAC
5 A (5 A) at 30 VDC
8 A (8 A) at 250 VAC
8 A (8 A) at 30 VDC
3.5 A (3.5 A) at 250 VAC
3.5 A (3.5 A) at 30 VDC
Item
Contact type
Contact material
Single
Ag-Alloy (Cd free)
Rated carry current
10 A (10 A)
10 A (10 A)
8 A (8 A)
8 A (8 A)
Max. switching voltage
Max. switching current
380 VAC, 125 VDC
Note. The values shown in parentheses ( ) are for -FD models only.
3
G6C
PCB Power Relay
■Characteristics (Including models for ultrasonically cleanable)
Item
Classification
Single-side Stable
Single-winding Latching Double-winding Latching
30 m max.
Contact resistance *1
Operate (set) time
Release (reset) time
Min. set pulse width
Min. reset pulse width
Ω
10 ms max.
10 ms max.
−
−
20 ms (at 23°C)
20 ms (at 23°C)
Between coil and
1,000 M
1,000 M
Ω
Ω
min.
min.
contacts
Between contacts of the
same polarity
Insulation
resistance *2
Between contacts of
different polarity
Between set and reset
coils
1,000 M
Ω
min. (SPST-NO, SPST-NC)
1,000 MΩ min.
−
−
Between coil and
contacts
Between contacts of the
same polarity
2,000 VAC 50/60Hz for 1min
1,000 VAC 50/60Hz for 1min
Dielectric
strength
Between contacts of
different polarity
2,000 VAC 50/60Hz for 1min (SPST-NO, SPST-NC)
250 VAC 50/60Hz for
1min
Between set and reset
coils
−
−
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Vibration
resistance
1,000 m/s2
100 m/s2
Shock
resistance
Note. The given values are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage
drop method.
*2. Testing conditions: measured with a 500 VDC
megohmmeter (at 250 VDC between set/reset
coil).
*3. This value was measured at a switching
frequency of 120 operations/min.
50,000,000 operations min. (at 18,000 operations/hr)
100,000 operation min. (at 1,800 operations/hr under rated load)
10 mA at 5 VDC
Durability
G
6
C
Failure rate (P level) (reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
-25°C to 70°C (with no icing or condensation)
5% to 85%
Approx. 5.6 g
■Engineering Data
● Maximum Switching Capacity
G6C-1114P-US
G6C-1117P-US
G6C-1114P-FD-US
G6C-1117P-FD-US
G6C-2114P-US
G6C-2117P-US
50
50
50
30
30
30
AC resistive load
AC resistive load
AC resistive load
10
10
8
10
8
7
5
5
5
3
3
3
AC inductive
DC resistive load
AC inductive
load
(cosφ = 0.4)
DC resistive load
AC inductive
load
(cosφ = 0.4)
2
2
load
DC resistive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
1
0.7
0.5
1
0.7
0.5
1
0.7
0.5
DC inductive load
(L/R = 7 ms)
0.3
0.2
0.3
0.2
0.3
0.2
0.1
0.1
0.1
1
3
5
7 10
30 50 100
250 380 1,000
1
3
5
7 10
30 50 100
250 380 1,000
1
3
5
7 10
30 50 100
250 380 1,000
Switching voltage (V)
Switching voltage (V)
Switching voltage (V)
G6C-2114P-FD-US
G6C-2117P-FD-US
50
30
AC resistive load
10
8
5
3
2
AC inductive
load
(cosφ = 0.4)
DC resistive load
1
0.7
0.5
DC inductive load
(L/R = 7 ms)
0.3
0.2
0.1
1
3
5
7 10
30 50 100
250 380 1,000
Switching voltage (V)
4
G6C
PCB Power Relay
●Durability
G6C-1114P-US, G6C-2114P-US
G6C-1117P-US, G6C-2117P-US
G6C-1114P-FD-US, G6C-2114P-FD-US
G6C-1117P-FD-US, G6C-2117P-FD-US
500
500
G6C-2114P-FD-US
300
300
G6C-2117P-FD-US
250 VAC resistive
30 VDC resistive
G6C-1114P-FD-US
G6C-1117P-FD-US
250 VAC resistive
G6C-2114P-US
G6C-2117P-US
100
100
250 VAC resistive
30 VDC resistive
G6C-1114P-US
G6C-1117P-US
250 VAC resistive
30 VDC resistive
G6C-1114P
-FD-US
G6C-1117P
-FD-US
50
30
50
30
30 VDC resistive
10
10
G6C-2114P-US
G6C-1114P-US
G6C-1114P-FD-US
G6C-2114P-FD-US
G6C-2117P-FD-US
250 VAC inductive
(cosφ = 0.4)
G6C-2117P-US
250 VAC inductive
(cosφ = 0.4)
30 VDC inductive
(L/R = 7 ms)
5
3
5
3
G6C-1117P-US
250 VAC inductive
(cosφ = 0.4)
30 VDC inductive
(L/R = 7 ms)
G6C-1117P-FD-US
250 VAC inductive
(cosφ = 0.4)
30 VDC inductive
(L/R = 7 ms)
30 VDC inductive
(L/R = 7 ms)
1
1
0
1
2
3
4
5
6
7
8
9
10 11
0
1
2
3
4
5
6
7
8
9
10 11
Switching current (A)
Switching current (A)
●Ambient Temperature vs.
Maximum Coil Voltage
200
● Ambient Temperature vs Must
Operate and Must Release voltages
100
Must operate voltage
Sample:
G6C-114P-US
Number of Relays:
5 pcs
Must release voltage
180
160
max.
80
60
40
20
X
min.
G
6
C
140
130
120
max.
100
X
min.
80
60
0
-40
10 20 23 30
40
50
60
70
80 90
-20
0
20
40
60
80
Ambient temperature (°C)
Ambient temperature (°C)
Note. The maximum coil voltage refers to the
maximum value in a varying range of
operating power voltage, not a continuous
voltage.
●Shock Malfunction
Magnetic Interference (between Relays)
De-energized
(b contact)
Energized
(a contact)
3
Y
Y
600
600
2
400
200
400
200
X
600
Z
600
X
600
Z
600
1
max.
400
400
400
400
400
400
X
min.
200
200
200
200
200
200
0
l2
200
200
Sample
200
400
200
400
500
-1
400
600
X'
600
X'
Z'
600
Z'
600
l1
Shock direction
-2
-3
X
X'
600
Y'
600
Y'
Y
Unit: m/s2
Unit: m/s2
(Mounting pitch)
Z
Z'
Initial l1=2.54a
l2=5.08a
l1=5.08a l1=7.62a
l2=7.62a l2=10.16a
Y'
(coil)
Sample: G6C-2114P-US DC24V
Number of Relays: 6 pcs
Test conditions: Shock is applied in ±X, ±Y, and ±Z
directions three times each with without energizing the
Relays to check the number of malfunctions.
Requirement: 100 m/s2
5
G6C
PCB Power Relay
■Dimensions
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1
Terminal
Flux Protection Model
G6C-@117P-US
Arrangement/
Internal Connections
(Bottom View)
1-pole
2.54
Four, 1.1-dia. holes
1-pole
2.54
1
3
4
−
20 max.
(19.9)*
15 max.
(14.9)*
+
(2.4)
8
10 max.
(9.9)*
0.3
10.16
7.62
(1.1)
3.5
2-pole
2.54
0.5
0.65<0.7>
0.9<1.0>
1.11
<0.4>
0.9<1.0>
Six, 1.1-dia. holes
10.16
10.16
7.62
* Average value
2-pole
2.54
1
3
6
4
5
−
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
+
(2.4)
8
Note: Check carefully the coil
polarity of the Relay.
10.16
7.62
(1.1)
Note: Orientation mark is indicated as follows:
G
6
C
PCB Mounting Holes Terminal Arrangement/
Fully Sealed Model
G6C-@114P-US
(Bottom View)
Internal Connections
1-pole
2.54
Tolerance: ±0.1
(Bottom View)
Four, 1.1-dia. holes
1-pole
2.54
1
3
4
−
+
20 max.
(19.9)*
15 max.
(14.9)*
(2.4)
8
10.16
7.62
10 max.
(9.9)*
0.3
(1.1)
2-pole
2.54
3.5
Six, 1.1-dia. holes
0.5
2-pole
0.65<0.7>
0.9<1.0>
1.11
<0.4>
0.9<1.0>
2.54
10.16
10.16
1
3
6
4
5
7.62
* Average value
−
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
+
(2.4)
8
Note: Check carefully the coil
polarity of the Relay.
10.16
7.62
(1.1)
6
G6C
PCB Power Relay
PCB Mounting Holes Terminal
Flux Protective
Single-winding Latching Model
G6CU-@117P-US
(Bottom View)
Tolerance: ±0.1
Arrangement/Internal
Connections
1-pole
2.54
Four, 1.1-dia. holes
1-pole
2.54
1
3
4
−
+
S R
20 max.
(19.9)*
15 max.
(14.9)*
+
−
(2.4)
8
10 max.
(9.9)*
S: Set coil
R: Reset coil
10.16
7.62
0.3
(1.1)
3.5
2-pole
2.54
0.5
0.65<0.7>
0.9<1.0>
1.11
<0.4>
0.9<1.0>
10.16
10.16
Six, 1.1-dia. holes
7.62
* Average value
2-pole
2.54
1
3
4
5
−
+
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
S R
+
−
(2.4)
8
6
Note: Check carefully the coil
polarity of the Relay.
10.16
7.62
(1.1)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1
Terminal
Arrangement/Internal
Connections
Fully Sealed Model
Single Latching Models
G6CU-@114P-US
G
6
C
1-pole
2.54
Four, 1.1-dia. holes
1-pole
2.54
1
3
4
−
+
S R
20 max.
(19.9)*
15 max.
(14.9)*
+
−
(2.4)
8
10 max.
(9.9)*
S: Set coil
R: Reset coil
10.16
7.62
0.3
(1.1)
3.5
2-pole
2.54
0.5
0.65<0.7>
0.9<1.0>
1.11
<0.4>
0.9<1.0>
10.16
10.16
Six, 1.1-dia. holes
7.62
* Average value
2-pole
2.54
1
3
4
5
−
+
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
S R
+
−
(2.4)
8
6
Note: Check carefully the coil
polarity of the Relay.
10.16
7.62
(1.1)
Note: Orientation marks are indicated as follows:
7
G6C
PCB Power Relay
PCB Mounting Holes Terminal Arrangement/
Flux Protective
Double-winding Latching Model
G6CK-@117P-US
(Bottom View)
Internal Connections
Tolerance: ±0.1
(Bottom View)
1-pole
2.54
Six, 1.1-dia. holes
1-pole
2.54
1
2
3
4
−
S
+
−
R
+
20 max.
(19.9)*
15 max.
(14.9)*
(2.4)
8
7
S: Set coil
R: Reset coil
2.54
7.62
7.62
10 max.
(9.9)*
0.3
(1.1)
3.5
2-pole
2.54
0.9
<1.0>
0.5
0.65<0.7>
0.9<1.0>
1.11
<0.4>
0.9<1.0>
10.16
Eight, 1.1-dia. holes
10.16
2-pole
7.62
* Average value
2.54
1
2
7
3
6
4
5
−
S
+
−
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
R
+
(2.4)
8
Note: Check carefully the coil
polarity of the Relay.
7.62
7.62
2.54
(1.1)
PCB Mounting Holes Terminal Arrangement/
Fully Sealed
Double-winding Latching Model
G6CK-@114P-US
(Bottom View)
Internal Connections
G
6
C
1-pole
2.54
Tolerance: ±0.1
(Bottom View)
Six, 1.1-dia. holes
1-pole
2.54
1
2
3
4
−
S
+
−
R
+
20 max.
(19.9)*
15 max.
(14.9)*
(2.4)
8
7
S: Set coil
R: Reset coil
10 max.
(9.9)*
7.62
7.62
0.3
2.54
(1.1)
3.5
0.9
2-pole
2.54
<1.0>
0.5
0.65<0.7>
0.9<1.0>
1.11
<0.4>
0.9<1.0>
10.16
Eight, 1.1-dia. holes
10.16
2-pole
7.62
2.54
* Average value
1
2
7
3
6
4
5
−
S
+
−
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
R
+
(2.4)
8
Note: Check carefully the coil
polarity of the Relay.
7.62
7.62
2.54
(1.1)
8
G6C
PCB Power Relay
■Connecting Sockets Dimensions
Socket for single-winding latching/single-side a table Models
P6C-06P
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance:
23.2max.
(23)*
0.1 mm
15max.
(14.9)*
Six, 1.1-dia. holes
3.1
2.54
2.54
(2.4)
10.8max.
(10.6)*
7.5
3.5
10.16
7.62
(2.61)
0.8
0.4
10.16
7.62
0.1
* Average value
10.16
Socket for double-winding latching Models
P6C-08P
23.2max.
(23)*
PCB Mounting Holes
(BOTTOM VIEW)
0.1 mm
Tolerance:
15max.
(14.9)*
3.1
G
6
C
Eight, 1.1-dia. holes
2.54
2.54
(2.4)
10.8max.
(10.6)*
7.5
3.5
0.8
0.4
7.62
7.62
(2.61)
2.54
7.62
7.62
2.54
0.1
* Average value
10.16
Note: Orientation marks are indicated as follows:
9
G6C
PCB Power Relay
■Removal Tool
■Hold-down Clips
P6B-Y1
P6B-C2
■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined
in this catalog.
UL Recognized
(File No. E41643)
Coil ratings
Number of
Number of test
operations
Model
Contact ratings
poles
10 A, 250 VAC 80°C
10 A, 30 VDC 80°C
1/6 HP 250 VAC, 1/4 HP, 125 VAC 80°C
1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C
600 W, 120 VAC, (Tungsten) 80°C
530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C
43.2 VA, 30 VDC (Pilot Duty) 80°C
12 LRA, 2.2 FLA 30 VDC 80°C
8 A, 250 VAC 80°C
8 A, 30 VDC 80°C
6,000
30,000
6,000
1
G
6
C
G6C ( )
3 to 24 VDC
1/6 HP, 125 VAC, 1/4 HP, 125 VAC 80°C
1/4 HP, 250 VAC 80°C
600 W, 120 VAC (Tungsten) 80°C
2
530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C
43.2 VA, 30 VDC (Pilot Duty) 80°C
12 LRA, 2.2 FLA, 30 VDC 80°C
30,000
CSA Certified
(File No. LR31928)
Coil ratings
Number of
Number of test
operations
Model
Contact ratings
poles
10 A, 250 VAC 80°C
10 A, 30 VDC 80°C
1/6 HP 125 VAC, 1/4 HP, 125 VAC 80°C
1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C
600 W, 120 VAC, (Tungsten) 80°C
1
530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C
43.2 VA, 30 VDC (Pilot Duty) 80°C
8 A, 250 VAC 80°C
8 A, 30 VDC 80°C
G6C ( )
3 to 24 VDC
6,000
1/6 HP, 125 VAC, 1/4 HP, 125 VAC 80°C
1/4 HP, 250 VAC 80°C
600 W, 120 VAC (Tungsten) 80°C
2
530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C
43.2 VA, 30 VDC (Pilot Duty) 80°C
EN/IEC, VDE Certified
(Certificate No. 40014439)
Approved
switching
operations
Number of
Model
poles
Coil ratings
Contact ratings
10 A, 250 VAC (cosφ = 1) 40°C
5 A, 250 VAC (cosφ = 0.4) 40°C
7 A, 250 VAC (cosφ = 1) 40°C
3.5 A, 250 VAC (cosφ = 0.4) 40°C
1
3, 5, 6, 12, 24 VDC
G6C ( )
20,000
• Single-stable:
3, 5, 6, 12, 24 VDC
2
EN/IEC, TÜV Certified
(Registration No. R50158249)
Coil ratings
Approved
switching
operations
Number of
Model
poles
Contact ratings
10 A, 250 VAC (cosφ = 1) 40°C
5 A, 250 VAC (cosφ = 0.4) 40°C
10 A, 30 VDC (L/R = 0 ms) 40°C
8 A, 250 VAC (cosφ = 1) 40°C
3.5 A, 250 VAC (cosφ = 0.4) 40°C
8 A, 30 VDC (L/R = 0 ms) 40°C
• Single-stable:
3, 5, 6, 12, 24 VDC
• Latching:
1
2
G6C ( )
20,000
3, 5, 6, 12, 24 VDC
10
G6C
PCB Power Relay
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Mounting
●Sockets
●Using SPDT contact of the
SPST-NO+SPST-NC Relay
• Do not reverse the polarity of the coil
(+, −).
• Do not construct a circuit so that
overcurrent and burning occur if the
NO, NC and SPDT contacts are short-
circuited with the SPST-NO+SPST-NC
Relay. Arcing may generate short-
circuiting between contacts if there is
short-circuiting because of conversion
to the MBB contact caused by
17 mm max. for sockets
7.5 mm
• When mounting more than two relays
side by side, keep the gap between
Relays as shown below to ensure a
good heat dissipation. It may result in
malfunction if heat is not dissipated
smoothly from the Relay.
• When mounting the Relay, make sure
to insert the Relay terminals
perpendicularly and correctly into the
socket contact pin.
• Hold-down clips (for mounting and
removal) are also available.
asynchronous operation of the NO and
NC contacts, the interval between the
NO and NC contacts is small, or a
large current is left open.
2.54 mm ×
3 pitch min.
between
terminals
• The P6C model has a flux-resistant
construction. Do not wash it down with
water.
●Other precautions
2.54 mm × 2 pitch min. between terminals
• The max. carry current of sockets is 5A.
• This Relay is a Power Relay which is
suitable for power load switching. Do
not use the G6C for signal purposes
such as micro load switching under
10 mA.
●Double-winding Latching Circuit
• It is recommended to perform wiring of
No.1 and No.2 of the negative (-)
terminal as COM wiring, in order to
improve the operation stability for
G
6
C
Double-winding Latching.
(+)
+
−
8
+
−
7
R
2
S
1
COM
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K018-E1-09
0316(0207)(O)
11
相关型号:
G6CK-2117C-USP6C-6
Power/Signal Relay, DPST, Latched, 0.047A (Coil), 6VDC (Coil), 280mW (Coil), 8A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON