G6K-2F-RF-T
更新时间:2024-09-18 22:05:29
品牌:OMRON
描述:Surface Mount, 1GHz / 3 GHz Miniature DPDT, High Frequency Relay
G6K-2F-RF-T 概述
Surface Mount, 1GHz / 3 GHz Miniature DPDT, High Frequency Relay
G6K-2F-RF-T 数据手册
通过下载G6K-2F-RF-T数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载High Frequency Relay
G6K-RF
Surface Mount, 1GHz / 3 GHz Miniature
DPDT, High Frequency Relay
• New Models with 3 GHz band available (“-T” versions)
• Space-saving 1 GHz version with smaller ground terminal footprint
is available. (“-S” versions)
• Handles 1 A, 30 VDC discrete load and 1 W at 1GHz.
• Single-coil latching models available.
• Low coil power consumption: 100 mW.
• Ideal for instrumentation and high-speed LAN network equipment.
• RoHS Compliant
Ordering Information
PCB Footprint
Max.Load
Coil Voltage
3 VDC
Non-Latching part number
G6K-2F-RF DC3
Single-coil latching part number
G6KU-2F-RF DC3
Standard ground 1 A at 30 VDC,
terminal
(1GHz)
0.3 A at 125 VDC
4.5 VDC
5 VDC
G6K-2F-RF DC4.5
G6K-2F-RF DC5
G6KU-2F-RF DC4.5
G6KU-2F-RF DC5
12 VDC
24 VDC
3 VDC
G6K-2F-RF DC12
G6K-2F-RF DC24
G6K-2F-RF-S DC3
G6K-2F-RF-S DC4.5
G6K-2F-RF-S DC5
G6K-2F-RF-S DC12
G6K-2F-RF-S DC24
G6K-2F-RF-T DC3
G6K-2F-RF-T DC4.5
G6K-2F-RF-T DC5
G6K-2F-RF-T DC12
G6K-2F-RF-T DC24
G6KU-2F-RF DC12
G6KU-2F-RF DC24
Space-saving
ground terminal
(1 GHz)
G6KU-2F-RF-S DC3
G6KU-2F-RF-S DC4.5
G6KU-2F-RF-S DC5
G6KU-2F-RF-S DC12
G6KU-2F-RF-S DC24
G6KU-2F-RF-T DC3
G6KU-2F-RF-T DC4.5
G6KU-2F-RF-T DC5
G6KU-2F-RF-T DC12
G6KU-2F-RF-T DC24
4.5 VDC
5 VDC
12 VDC
24 VDC
3 VDC
Space-saving
ground terminal
(3GHz)
4.5 VDC
5 VDC
12 VDC
24 VDC
Note: The above listed models are packaged in trays of 300. They are also available in Tape and Reel packaging.
1. Place “-TR03” before the coil voltage to obtain Tape and Reel packaging, in quantities of 300 pieces per reel.
2. Place “-TR09” before the coil voltage to obtain Tape and Reel packaging, in quantities of 900 pieces per reel.
Examples: G6K-2F-RF-S-TR09 DC5
G6KU-2F-RF-TR03 DC12
3. “-TR03” and “-TR09” is only used to identify the tape quantity when ordering and is not marked on the product, itself.
Specifications
■ Contact Ratings
Load
Resistive load
Rated load
0.3 A at 125 VAC; 1 A at 30 VDC
1 W at 1 GHz (See note.)
Rated carry current
1 A
Max. switching voltage
125 VAC, 60 VDC
1 A
Max. switching current
Max. switching capacity
37.5 VA (AC); 30 W (DC)
Note: This value is for a load with V.S.W.R. ≤ 1.2
High Frequency Relay G6K-RF
1
■ Coil Ratings
Rated voltage
Rated current
Coil resistance Must operate
voltage
Must release
voltage
Maximum voltage
Rated power
consumption
3 VDC
33.0 mA
23.2 mA
21.1 mA
9.1 mA
91 Ω
80% max. of rated 10% min. of rated 150% of rated voltage Approx. 100 mW
voltage voltage
4.5 VDC
5 VDC
194 Ω
237 Ω
1,315 Ω
5,220 Ω
(75% max. of rated (75% max. of rated
12 VDC
24 VDC
set voltage for
latching models)
reset voltage for
latching models)
4.6 mA
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
■ High Frequency Characteristics
1 GHz, all models
3 GHz, “-T” models
Isolation
between contacts of
the same pole
20 dB min.
18 dB min.
between contacts of
different poles
30 dB min.
25 dB min.
Insertion loss
0.2 dB max.
1.2 max.
0.6 dB max.
1.4 max.
V.S.W.R.
Maximum transmission capacity
Maximum switching capacity
3 W (See note 3)
1 W (See note 3)
Note: 1. The impedance of the measurement system is 50 Ω.
2. The above values are initial
3. These values are for a load with V.S.W.R. ≤ 1.2
4. Contact Omron if the relay will be used in an application that requires high repeatability in high-frequency characteristics for the microload
region. (Such applications include Test and Measurement equipment and ATE applications.)
■ Characteristics
Item
Single-side stable models
G6K-2F-RF(-S)(-T)
Single-winding latching models
G6KU-2F-RF(-S)(-T)
Contact resistance (See note 2.)
Operating (set) time (See note 3.)
Release (reset) time (See note 3.)
Minimum set/reset pulse time
Insulation resistance (See note 4.)
100 mΩ max.
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 1.3 ms)
---
3 ms max. (approx. 1.2 ms)
3 ms max. (approx. 1.2 ms)
10 ms
1,000 MΩ min. (at 500 VDC)
750 VAC, 50/60 Hz for 1 min
Dielectric strength
Between coil and
contacts
Between contacts of
different poles
750 VAC, 50/60 Hz for 1 min
Between contacts of the 750 VAC, 50/60 Hz for 1 min
same pole
Between ground and
coil/contacts
500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 5-mm double amplitude and 55 to 500 to 55 Hz, 300 m/s2
10 to 55 Hz, 3.3-mm double amplitude and 55 to 500 to 55 Hz, 200 m/s2
1,000 m/s2
Vibration resistance
Shock resistance
Endurance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
750 m/s2
50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)
100,000 operations min. (at a switching frequency of 1,800 operations/hour)
Operating: −40°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Ambient operating temperature
Ambient operating humidity
Weight
Approx. 0.95 g
Note: 1. The above values are initial values.
2. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
3. Values in parentheses are typical values.
4. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.
2
High Frequency Relay G6K-RF
Engineering Data
G6K-2F-RF
Agile HP 8753D
Vector Network
Analyzer
50 Ω
terminaltion
High-Frequency Characteristics
(Isolation)
High-frequency Characteristics
(Insertion Loss)
High-frequency Characteristics
(Return Loss, V.S.W.R.)
G6K-2F-RF
G6K-2F-RF
G6K-2F-RF
Average value (initial)
Average value (initial)
Average value (initial)
0
0
1.8 V
0
Test subject: G6K-2F-RF
Number of Units: 5
Test subject: G6K-2F-RF
Number of Units: 10
Test subject: G6K-2F-RF
Number of Units: 10
·
S
W
10
1.7
10
R
0.1
20
30
40
50
60
70
1.6
20
30
1.5
1.4
1.3
1.2
0.2
0.3
40
50
60
Return loss
V.SWR
0.4
0.5
1.1
1.0
70
80
90
80
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
Frequency (GHz)
Frequency (GHz)
Frequency (GHz)
G6K-2F-RF-S
G6K-2F-RF-S
G6K-2F-RF-S
Average value (initial)
Average value (initial)
Average value (initial)
0
0
1.8
0
V
·
S
W
R
Test subject: G6K-2F-RF-S
Number of Units: 5
Test subject: G6K-2F-RF-S
Number of Units: 10
Test subject: G6K-2F-RF-S
Number of Units: 10
10
20
30
40
50
60
70
1.7
10
20
30
40
50
60
0.1
0.2
0.3
1.6
1.5
1.4
1.3
1.2
Return loss
V.SWR
0.4
0.5
1.1
1.0
70
80
90
80
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
Frequency (GHz)
Frequency (GHz)
Frequency (GHz)
G6K-2F-RF-T
G6K-2F-RF-T
G6K-2F-RF-T
Average value (initial)
Average value (initial)
Average value (initial)
0
0.0
2.6
2.4
0
V
·
S
W
R
N.O.
N.C.
Test subject: G6K-2F-RF-T
Number of Units: 5
N.O.
N.C.
Test subject: G6K-2F-RF-T
Number of Units: 5
N.O.
N.C.
Test subject: G6K-2F-RF-T
Number of Units: 5
10
20
30
40
50
60
70
10
20
30
40
50
60
0.2
0.4
0.6
2.2
2.0
1.8
1.6
1.4
Return loss
V.SWR
0.8
1.2
1.0
70
80
90
1.0
80
0
1
2
3
4
5
6
0
1
2
3
4
5
6
0
1
2
3
4
5
6
Frequency (GHz)
Frequency (GHz)
Frequency (GHz)
Note: 1. Refer to the G6K specification for basic specifications and characteristics not shown above
2. Ambient temperature condition: 23°C
3. The high-frequency characteristics depend on the mounting board. Be sure to check actual operation, including durability, in
actual equipment before use.
High Frequency Relay G6K-RF
3
Dimensions
Note: All dimensions are in millimeters unless otherwise indicated
Mounting Dimensions
(Top View)
Terminal Arrangement and
Internal Connections
(Top View)
G6K-2F-RF
G6KU-2F-RF
Tolerance 0.1 mm
G6K-2F-RF
7.6
Orientation mark
5.4
3.2
8
7
6
5
4
12.8
−
10.3
0.5
2.5
0.6
6.9
1.8
+
7
1
2
3
5.4
0.3
2.5
0.8
0.5
1.35
7.8
G6KU-2F-RF
(1.35)
Orientation mark
3.2
5.4
1.95
8
7
6
5
11.5
7.6
− +
S R
+ −
Note: 1. Each value has a tolerance of 0.3 mm
2. The coplanarity of the terminals is 0.15 mm max.
Note: Check carefully the coil
1
2
3
4
polarity of the relay
Mounting Dimensions
(Top View)
Terminal Arrangement and
Internal Connections
(Top View)
G6K-2F-RF-S
G6KU-2F-RF-S
0.85
1.55
1.5
Tolerance 0.1 mm
0.85
G6K-2F-RF-S
8.8
7.6
Orientation mark
5.4
G6K-2F-RF-S
7.8 8.6
3.2
1.2
8
7
2
6
3
5
4
VDC
JAPAN
1.6
−
+
10.7
10.3
2.1
1.8
7.5
7
1
0.6
6.9
G6KU-2F-RF-S
5.4
(1.35)
1
0.8
0.3
Orientation mark
1.8
0.5
1.35
8
7
6
5
3.2
5.4
− +
S R
7.6
+ −
Note: Check carefully the coil
polarity of the relay
Note: 1. Each value has a tolerance of 0.3 mm
2. The coplanarity of the terminals is 0.15 mm max.
1
2
3
4
Mounting Dimensions
(Top View)
Terminal Arrangement and
Internal Connections
(Top View)
G6K-2F-RF-T
G6KU-2F-RF-T
0.85
0.5
0.85
Tolerance 0.1 mm
G6K-2F-RF-T
7.6
Orientation mark
5.4
3.2
7.8
8.6
G6K-2F-RF-T
8
7
2
6
3
5
4
VDC
1.1
JAPAN
4-1.15
1.35
−
2.2
2.2
+
4.8
4.8
1
10.7
10.3
7
10.8
1.1
6.9
G6KU-2F-RF-T
Orientation mark
0.6
2.2 2.2
(2.45)
5.4
1.35
14-0.8
0.3
8
7
6
5
− +
0.5
Note: 1. Each value has a tolerance of 0.3 mm
2. The coplanarity of the terminals is 0.15 mm max.
S R
1.35
3.2
5.4
7.6
+ −
1
2
3
4
Note: Check carefully the coil
polarity of the relay
4
High Frequency Relay G6K-RF
Tape Packaging Specifications
• Add “-TR03” or “-TR09” before the coil voltage to order relays in Tape and Reel packaging. If “-TR03” or “-TR09” is not included, then the relays
will be provided in trays of 300 relays per tray.
- - Add “-TR03” to obtain 300 relays per reel
- - Add “-TR09” to obtain 900 relays per reel
1. Direction of Relay insertion
3. Carrier Tape Dimensions
G6K(U)-2F-RF
5.9 0.1
Top tape
(cover tape)
12 1.0
4
1.5+0.1 dia.
0.1
0
1.75 0.1
11.5 0.1
2
0.1
0.4 0.1
B
A
24 0.2
13.4 0.1
Carrier tape
10.9 0.1
Embossed
tape
0°
3°−1°
Pulling Direction
B-B Cross Section
B
G6K(U)-2F-RF
G6K(U)-2F-RF-S(-T)
A
Orientation mark
Orientation mark
4.25 0.1
0°
3°−1°
Pulling
direction
Pulling
direction
A-A Cross Section
8.5 0.1
G6K(U)-2F-RF-S
2. Reel Dimensions
5.9 0.1
12 0.1
4
0.1
1.5+0.1 dia.
1.75 0.1
0
2
0.1
0.4 0.05
B
A
29.5
1
25.5 0.5
11.5 0.1
24 0.3
13 0.2 dia.
21 0.8 dia.
2
0.5
11.3 0.1
A
3° max.
B-B Cross Section
B
330 80
A
3° max.
9.2 0.1
R1
Enlarged View of Section A
A-A Cross Section
High Frequency Relay G6K-RF
5
Precautions
■ Recommended Soldering Method
1. Temperature Profile for Lead Solder (Measured at the PCB)
2. Temperature Profile for Lead-free Solder (Measured at the PCB)
Case top panel
(peak): 255°C max.
Soldering
250 max.
Soldering
220 to
245
230
180
180 to
200
Preheating
150
Preheating
150
Relay terminal
section
120 max.
30 max.
Time (s)
90 to 120
20 to 30
Time (s)
3. The thickness of cream solder to be applied should be between 200 and 250 μm and the land pattern should be based on Omron’s recommended
PCB pattern. To maintain the correct soldering joint shown in the following diagram, we recommend applying solder using the soldering conditions
shown above. Check the soldering in the actual mounting conditions prior to use.
Correct Soldering
Incorrect Soldering
Relay
Terminal
Land
PCB
Excessive amount
of solder
Insufficient amount
of solder
Heel fillet
is formed
Solder
■ Precautions for correct use
Be sure to read the precautions and information common to all Electromechanical Relays, contained in the Technical User's Guide, "Electrome-
chanical Relays, Technical Information, for correct use.
Relay Handling
Claw Securing Force During Automatic Mounting
Do not unpack the relay until ready to mount it. Use the relay as soon as
possible after opening the moisture-proof bag. Otherwise, the terminals
may tarnish and seal failure may occur after the solder process.
During automatic insertion of relays, make sure to set the securing
force of each claw to the following so that the relay’s characteristics
will be maintained.
When washing the product after soldering, use a water-based or
alcohol-based solvent. Keep the solvent temperature below 40°C.
Do not put the relay in a cold cleaning bath immediately after soldering.
C
Direction A: 1.96 N max.
Direction B: 4.90 N max.
Direction C: 1.96 N max.
B
Operating, Storage Environment
Secure the claws to the shaded area. Do not
attach them to the center of the relay or just
one part of the relay.
If the relay is stored for a long time in an adverse environment with high
temperature, high humidity, organic or sulfide gases, then sulfide or
oxide films will form on the contact surfaces. These films may result in
unstable contact, contact problems or function problems. Therefore,
operate, store or transport the product under specified environmental
conditions.
Maximum Allowable Voltage
The maximum allowable voltage of the coil can be obtained from the
coil temperature increase and the heat-resisting temperature of the
coil insulating sheath material. (Exceeding the heat-resisting tem-
perature may result in burning or short-circuiting.) The maximum
allowable voltage also involves important restrictions which include
the following;
1. Use in locations where the relay is not exposed to corrosive
gas such as hydrogen sulfide gas or salty air.
2. Use in locations where no visible dust exists.
3. Use, store and transport in locations where the product is not
exposed to direct sunlight, rain or snow.
4. Do not apply force to the product which may result in deformation
or change in quality of the product.
•
Must not cause thermal changes in or deterioration of the insulating
material, which may result in films developing on the contacts.
• Must not cause damage to other control devices.
• Must not cause any harmful effect on people.
• Must not cause fire.
Coating
The relay mounted on the PCB may be coated or washed, but do not
apply silicone coating or detergent containing silicone, otherwise, the
silicone coating or detergent may remain on the surface of the relay.
Therefore, be sure to use the maximum allowable voltage as specified in
the catalog. As a rule, the rated voltage must be applied to the coil. Con-
sider using a latching relay instead of a non-latching relay with a continu-
ous voltage applied to the coil.
Latching Relay Mounting
Long-term, Continuous ON contacts
Make sure that excess vibration or shock doesn’t set or reset the
relay during normal operation. The relay is shipped in the ‘reset’
position. Shock or vibration during shipping may require the application
of a reset signal, prior to operation.
Using the relay where it will remain continuously energized for long
periods of time can lead to unstable contacts. We recommend using
a latching relay for this type of application.
6
High Frequency Relay G6K-RF
MEMO
High Frequency Relay G6K-RF
7
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
847-882-2288
Cat. No. K242-E-02
06/14 (01/12)
Specifications subject to change without notice
Printed in USA
8
High Frequency Relay G6K-RF
G6K-2F-RF-T 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
G6K-2F-RF-T-TR09DC3 | OMRON | RF Relay, | 获取价格 | |
G6K-2F-RF-T12 | OMRON | RF Relay | 获取价格 | |
G6K-2F-RF-T12VDC | OMRON | RF Relay, | 获取价格 | |
G6K-2F-RF-TDC3 | OMRON | RF Relay, | 获取价格 | |
G6K-2F-RF-TDC5 | OMRON | Surface Mount, 1GHz / 3 GHz Miniature DPDT, High Frequency Relay | 获取价格 | |
G6K-2F-RF-TR03DC6 | OMRON | RF Relay, DPDT, Momentary, 0.018A (Coil), 6VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-RF-TR03DC9 | OMRON | RF Relay, DPDT, Momentary, 0.011A (Coil), 9VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-RF-TR09DC24 | OMRON | RF Relay, DPDT, Momentary, 0.005A (Coil), 24VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-RF-TR09DC3 | OMRON | RF Relay, DPDT, Momentary, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-RF-TR09DC9 | OMRON | RF Relay, DPDT, Momentary, 0.011A (Coil), 9VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 |
G6K-2F-RF-T 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6