G6K-2F-Y-TR12VDC
更新时间:2024-09-18 19:00:08
品牌:OMRON
描述:Power/Signal Relay, DPDT, Momentary, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
G6K-2F-Y-TR12VDC 概述
Power/Signal Relay, DPDT, Momentary, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT 功率/信号继电器
G6K-2F-Y-TR12VDC 规格参数
是否无铅: | 不含铅 | 是否Rohs认证: | 符合 |
生命周期: | Active | 包装说明: | ROHS COMPLIANT |
Reach Compliance Code: | compliant | ECCN代码: | EAR99 |
HTS代码: | 8536.41.00.20 | 风险等级: | 5.12 |
主体宽度: | 6.5 mm | 主体高度: | 5.2 mm |
主体长度或直径: | 10 mm | 最大线圈电流(直流): | 0.009 A |
线圈工作电压(直流): | 9.6 V | 线圈功率: | 100 mW |
线圈释放电压(直流): | 1.2 V | 线圈电阻: | 1315 Ω |
最大线圈电压(直流): | 18 V | 标称线圈电压: | 12 V |
线圈/输入电源类型: | DC | 触点(交流)最大额定R负载: | .3A@125VAC |
最大触点电流(交流): | 0.3 A | 最大触点电流(直流): | 1 A |
触点(直流)最大额定R负载: | 1A@30VDC | 触点电阻: | 100 mΩ |
最大触点电压(交流): | 125 V | 最大触点电压(直流): | 30 V |
触点/输出电源类型: | AC/DC | 线圈与触点之间的介电强度: | 1500 Vrms |
断开触点之间的介电强度: | 750 Vrms | 电气寿命: | 100000 Cycle(s) |
末端触点材料: | Silver | 输入切换控制类型: | Random |
绝缘电阻: | 1000000000 Ω | 安装特点: | SURFACE MOUNT-STRAIGHT |
端子数量: | 8 | 工作时间: | 3 ms |
最高工作温度: | 70 °C | 最低工作温度: | -40 °C |
包装方法: | TR, 13 INCH | 物理尺寸: | 10mm x 6.5mm x 5.2mm |
参考标准: | BSI; CSA; UL | 继电器动作: | MOMENTARY |
继电器样式: | 2 FORM C | 继电器功能: | DPDT |
继电器类型: | POWER/SIGNAL RELAY | 释放时间: | 3 ms |
密封: | SEALED TYPE | 表面贴装: | NO |
端接类型: | SOLDER | 重量: | 0.7 g |
Base Number Matches: | 1 |
G6K-2F-Y-TR12VDC 数据手册
通过下载G6K-2F-Y-TR12VDC数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Surface-Mounting Signal Relay – G6K
Application Examples
Telephones, communications equipment, measurement devices, office automation machines, and audio–visual products.
Specifications
Contact mechanism: Bifurcated crossbar Ag (Au-alloy contact)
Enclosure ratings: Fully sealed
■
Coil Ratings
Single-side Stable Models – G6K-2F, G6K-2G, G6K-2P
Rated voltage
3 VDC
4.5 VDC
23.2 mA
194 Ω
5 VDC
21.1 mA
237 Ω
12 VDC
9.1 mA
1,315 Ω
Rated current
33.0 mA
Coil resistance
91 Ω
Must operate voltage
Must release voltage
Max. voltage
80% max. of rated voltage
10% min. of rated voltage
150% of rated voltage at 23°C to 70°C
Approx. 100 mW
Power consumption
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Single-side Stable Models (Bellcore Version) – G6K-2F-Y, G6K-2G-Y, G6K-2P-Y
Rated voltage
3 VDC
33.0 mA
91 Ω
4.5 VDC
23.2 mA
194 Ω
5 VDC
21.1 mA
237 Ω
12 VDC
9.1 mA
1,315 Ω
24 VDC
4.6 mA
5,220 Ω
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
80% max. of rated voltage
10% min. of rated voltage
150% of rated voltage at 23°C to 70°C
Approx. 100 mW
Power consumption
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Single-winding Latching Models (Bellcore Version) – G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y
Rated voltage
3 VDC
33.0 mA
91 Ω
4.5 VDC
23.2 mA
194 Ω
5 VDC
21.1 mA
237 Ω
12 VDC
9.1 mA
1,315 Ω
24 VDC
4.6 mA
5,220 Ω
Rated current
Coil resistance
Must Set voltage
Must reset voltage
Max. voltage
75% max. of rated voltage
75% max. of rated voltage
150% of rated voltage at 23°C to 70°C
Approx. 100 mW
Power consumption
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
215
Surface-Mounting Signal Relay – G6K
Contact Ratings
■
Load
Resistive load
Rated load
0.3 A at 125 VAC; 1 A at 30 VDC
Rated carry current
Max. switching voltage
Max. switching current
1 A
125 VAC, 60 VDC
1 A
■
Characteristics
Item
Single-side stable models (double-pole)
Single-winding latching
model
G6K-2F, G6K-2G, G6K-2P
100 mΩ max.
G6K-2F-Y, G6K-2G-Y,
G6K-2P-Y
G6KU-2F-Y, G6KU-2G-Y,
G6KU-2P-Y
Contact resistance
(see note 1)
Operating (set) time
(see note 2)
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 1.3 ms)
1,000 MΩ min. (at 500 VDC)
3 ms max. (approx. 1.2 ms)
3 ms max. (approx. 1.2 ms)
Release (reset) time
(see note 2)
Insulation resistance
(see note 3)
Dielectric Coil & contacts 1,500 VAC, 50/60 Hz for 1 min
strength
Contacts of
1,000 VAC, 50/60 Hz for 1 min
different polarity
Contacts of
750 VAC, 50/60 Hz for 1 min
same polarity
Impulse
withstand
voltage
Coil & contacts 1,500 V (10 x 160 µs)
2,500 V (2 x 10 µs), 1,500 V (10 x 160 µs)
Contacts of
1,500 V (10 x 160 µs)
different polarity
Contacts of
–
same polarity
Vibration resistance
Destruction: 10 to 55 Hz, 2.5-mm single amplitude (5-mm double amplitude)
and 55 to 500 Hz, 300 m/s2 (approx. 30G)
Malfunction: 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
and 55 to 500 Hz, 200 m/s2 (approx. 20G)
Shock resistance
Endurance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 750 m/s2 (approx. 75G)
Mechanical: 50,000,000 operations min. (at 36,000 operations/hour)
Electrical: 100,000 operations min. (with a rated load at 1,800 operations/hour)
Failure rate (P level)
(see note 4)
10 µA at 10 mVDC
Ambient temperature
Ambient humidity
Weight
Operating: -40°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 0.7 g
Note: The above values are initial values.
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those used for checking
the dielectric strength.
4. This value was measured at a switching frequency of 120 operations/min.
216
Surface-Mounting Signal Relay – G6K
Engineering Data
Maximum Switching Power
Ambient Temperature vs.
Maximum Coil Voltage
Ambient Temperature vs.
Switching Current
AC resistive load
DC resistive load
Ambient temperature (°C)
Ambient temperature (°C)
Switching voltage (V)
Note: The maximum coil voltage refers to the maxi
mum value in a varying range of operating
power voltage, not a continuous voltage.
Ambient Temperature vs. Must
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
Endurance
Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
Max. estimated value
Max. estimated value
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Must operate voltage
Must release voltage
Ambient temperature (°C)
Ambient temperature (°C)
Switching current (A)
Electrical Endurance
Electrical Endurance
Shock Malfunction
(with Must Operate and Must Re (Contact Resistance) (see note)
lease Voltage) (see note)
G6K-2G (F/P), G6K-2G (F/P)-Y
G6K-2G (F/P), G6K-2G (F/P)-Y
Energized
NO
Sample: G6K-2G
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load
at 30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Not
energized
contact
Number of Relays: 10
NC
contact
Test conditions: 1 A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Must operate
Contact resistance
Shock direction
Unit: m/s 2
Sample: G6K-2G
Number of Relays: 10
Must release
Conditions: Shock is applied in X, Y, and Z di
rections three times each with and with
out energizing the Relays to check the
number of contact malfunctions.
Operating frequency (x103operations)
Operating frequency (x103operations)
217
Surface-Mounting Signal Relay – G6K
Mutual Magnetic Interference
Mutual Magnetic Interference
G6K-2G (F/P), G6K-2G (F/P)-Y
Contact Reliability Test (see note)
G6K-2G (F/P), G6K-2G (F/P)-Y
G6K-2G (F/P), G6K-2G (F/P)-Y
Must operate voltage
Must release voltage
Must operate voltage
Must release voltage
NO
Sample: G6K-2G
Initial stage
Test
contact
NC
Number of Relays: 10
Initial stage
Test
Test conditions: 10 mA resistive load at
10 mVDC with an operation rate of 50 %
Switching frequency: 7,200 operations/h
contact
Sample
Sample
Not energized
Not energized
Average value
Test
Average value
Initial stage
Initial stage
Test
Sample
Sample
Energized
Energized
Average value
Average value
Operating frequency (x103operations)
Note: The test was conducted at an
ambient temperature of 23°C.
External Magnetic Interference
G6K-2G (F/P), G6K-2G (F/P)-Y
(Average value)
(Average value)
(Average value)
Sample: G6K-2G
Number of Relays: 10
Sample: G6K-2G
Number of Relays: 10
Must operate voltage
Must release voltage
Must operate voltage
Must release voltage
Sample: G6K-2G
Number of Relays: 10
Must operate voltage
Must release voltage
External magnetic field (A/m)
External magnetic field (A/m)
External magnetic field (A/m)
High-frequency Characteristics
(Isolation)
G6K-2G (F/P), G6K-2G (F/P)-Y
High-frequency Characteristics High-frequency Characteristics
(Insertion Loss)
(Return Loss)
G6K-2G (F/P), G6K-2G (F/P)-Y
G6K-2G (F/P),G6K-2G (F/P)-Y
(Average value)
(Average value)
(Average value)
Sample: G6K-2G
Number of Relays: 10
Sample: G6K-2G
Number of Relays: 10
Sample: G6K-2G
Number of Relays: 10
Return loss
Frequency (MHz)
Frequency (MHz)
Frequency (MHz)
218
Surface-Mounting Signal Relay – G6K
Must Operate and Must Release Must Operate and Must Release
Vibration Resistance
Time Distribution (see note)
G6K-2G (F/P), G6K-2G (F/P)-Y
Bounce Time Distribution (see note) G6K-2G (F/P), G6K-2G (F/P)-Y
G6K-2G (F/P) , G6K-2G (F/P)-Y
Sample: G6K-2G
Number of Relays:
50
Must operate
bounce time
Must release
bounce time
Must operate
Must release time
Must operate voltage
Must release voltage
Sample: G6K-2G
Number of Relays: 50
After test
Time (ms)
Time (ms)
Note: The tests were conducted at an ambient temperature of 23°C.
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
■
DPDT
Mounting Dimensions (Top View)
Tolerance: 0.1 mm
Terminal Arrangement/
Internal Connections
(Top View)
G6K-2F
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Top View) Terminal Arrangement/
G6K-2G
Internal Connections
(Top View)
Tolerance: 0.1 mm
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
G6K-2P
Tolerance: 0.1 mm
Eight, 0.8-dia. holes
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
219
Surface-Mounting Signal Relay – G6K
Mounting Dimensions (Top View) Terminal Arrangement/
Tolerance: 0.1 mm
G6K-2F-Y
Internal Connections
(Top View)
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Top View) Terminal Arrangement/
G6K-2G-Y
Internal Connections
(Top View)
Tolerance: 0.1 mm
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Bottom View) Terminal Arrangement/
Internal Connections
(Bottom View)
Tolerance: 0.1 mm
G6K-2P-Y
Eight, 0.8-dia. holes
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Terminal Arrangement/
Internal Connections
(Top View)
Mounting Dimensions (Top View)
Tolerance: 0.1 mm
G6KU-2F-Y
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Top View) Terminal Arrangement/
G6KU-2G-Y
Internal Connections
(Top View)
Tolerance: 0.1 mm
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
G6KU-2P-Y
Mounting Dimensions (Bottom View) Terminal Arrangement/
Internal Connections
(Bottom View)
Tolerance: 0.1 mm
Eight, 0.8-dia. holes
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
220
Surface-Mounting Signal Relay – G6K
Stick Packing and Tape Packing
Stick Packing
Relays in stick packing are arranged so that the orientation mark
of each Relay is on the left side. Fifty Relays are packed on one
stick.
Be sure not to make mistakes in Relay orientation when mounting
the Relay to the FPCB.
Orientation of Relays
Stopper (gray)
Stopper (green)
Stick length: 520 mm (stopper not included)
No. of Relays per stick: 50
Tape Packing (Surface-Mounting Terminal Models)
When ordering Relays in tape packing, add the prefix “-TR” to the
model number, otherwise the Relays in stick packing will be
provided.
Tape Type: ETX7200
(EIAJ (Electronic Industrial Association of Japan))
Reel type: RPM-16D (EIAJ)
Relays per Reel: 900
3. Carrier Tape Dimensions
1. Direction of Relay Insertion
Pulling direction
G6K-2F, G6K-2F-Y, G6KU-2F-Y
Orientation mark
Top tape (cover tape)
Pulling direction
Carrier tape
Emboss tape
G6K-2G, G6K-2G-Y, G6KU-2G-Y
2. Reel Dimensions
221
Surface-Mounting Signal Relay – G6K
Recommended Soldering Method
Temperatures indicate the surface temperatures of the PCB.
IRS Method (for surface-mounting terminal models)
°
Soldering
Preheating
Time (s)
• The thickness of cream solder to be applied should be within a range between 150 and 200 µm on OMRON’s recommended PCB
pattern.
• In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the
left side.
Correct Soldering
Incorrect Soldering
Relay
Insufficient
amount of
solder
Excessive
amount of
solder
Terminal
Solder
PCB
Land
Visually check that the Relay is properly soldered.
■
Approved Standards
UL approval: UL1950 (File No. E41515)
CSA approval: C22.2 No. 950 (File No. LR24825)
Model
Coil ratings
G6K-2G(F/P): 3 to 12 VDC
Contact ratings
Number of test operations
DPDT
1 A at 30 VDC
0.5 A at 60 VDC
0.3 A at 125 VAC
6,000
G6K(U)-2G(F/P)-Y: 3 to 24 VDC
222
Surface-Mounting Signal Relay – G6K
Precautions
CORRECT USE
Maximum Allowable Voltage
The maximum allowable voltage of the coil can be obtained from
the coil temperature increase and the heat-resisting temperature
of coil insulating sheath material. (Exceeding the heat-resisting
temperature may result in burning or short-circuiting.) The
maximum allowable voltage also involves important restrictions
which include the following:
Handling
Leave the Relay unpacked until mounting it.
Soldering
Solder: JIS Z3282, H63A
Soldering temperature: Approx. 250˚C (260˚C if the DWS method
is used)
• Must not cause thermal changes in or deterioration of the
insulating material.
Soldering time: Approx. 5 s max. (approx. 2 s for the first time and
approx. 3 s for the second time if the DWS method is used)
• Must not cause damage to other control devices.
• Must not cause any harmful effect on people.
• Must not cause fire.
Be sure to make a molten solder level adjustment so that the
solder will not overflow on the PCB.
Claw Securing Force During Automatic Mounting
Therefore, be sure to use the maximum allowable voltage beyond
the value specified in the catalog.
During automatic insertion of Relays, make sure to set the
securing force of each claw to the following so that the Relays
characteristics are maintained.
As a rule, the rated voltage must be applied to the coil. A voltage
exceeding the rated value, however, can be applied to the coil
provided that the voltage is less than the maximum allowable
voltage. It must be noted that continuous voltage application to
the coil will cause a coil temperature increase thus affecting
characteristics such as electrical life and resulting in the
deterioration of coil insulation.
Coating
The Relay mounted on the PCB may be coated or washed but do
not apply silicone coating or detergent containing silicone,
otherwise the silicone coating or detergent may remain on the
surface of the Relay.
Direction A: 1.96 N
Direction B: 4.90 N
Direction C: 1.96 N
Environmental Conditions During Operation, Storage, and
Transportation
PCB Mounting
Protect the Relay from direct sunlight and keep the Relay under
normal temperature, humidity, and pressure.
If two or more Relays are closely mounted with the long sides of
the Relays facing each other and soldering is performed with
infrared radiation, the solder may not be properly exposed to the
infrared rays. Be sure to keep the proper distance between
adjacent Relays as shown below.
If the Relay is stored for a long time in an adverse environment
with high temperature, high humidity, organic gases, or sulphide
gases, sulphide or oxide films will form on the contact surfaces.
These films may result in unstable contact, contact problems, or
functional problems. Therefore, operate, store, or transport the
product under specified environmental conditions.
G6K-2G
Latching Relay Mounting
Make sure that the vibration or shock that is generated from other
devices, such as relays in operation, on the same panel and
imposed on the Latching Relay does not exceed the rated value,
otherwise the Latching Relay that has been set may be reset or
vice versa. The Latching Relay is reset before shipping. If
excessive vibration or shock is imposed, however, the Latching
Relay may be set accidentally. Be sure to apply a reset signal
before use.
2 mm min.
G6K-2F
2.7 mm min.
Two or more Relays may be closely mounted with the short sides
of the Relays facing each other.
223
G6K-2F-Y-TR12VDC 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
G6K-2F-Y-TR4.5VDC | OMRON | Power/Signal Relay, DPDT, Momentary, 0.023A (Coil), 4.5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-Y-TRDC5 | OMRON | Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), DC Input, Random, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-Y12VDC-TR | OMRON | Electromechanical Relay, DPDT, 18VDC (Coil), 1A (Contact), 30VDC (Contact), Random, AC/DC Output, | 获取价格 | |
G6K-2F-Y24VDC | OMRON | Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.005A (Coil), 24VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-Y3VDC | OMRON | Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-Y4.5VDC | OMRON | Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.023A (Coil), 4.5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-Y5VDC-TR | OMRON | Electromechanical Relay, DPDT, 7.5VDC (Coil), 1A (Contact), 30VDC (Contact), Random, AC/DC Output, | 获取价格 | |
G6K-2F-YDC12 | OMRON | Power/Signal Relay, DPDT, Momentary, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-YDC24 | OMRON | Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.005A (Coil), 24VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), DC Input, Random, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 | |
G6K-2F-YDC4.5 | OMRON | Power/Signal Relay, DPDT, Momentary, 0.023A (Coil), 4.5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT | 获取价格 |
G6K-2F-Y-TR12VDC 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6